BLUEKIT VENTILATION FLAPS

Size: px
Start display at page:

Download "BLUEKIT VENTILATION FLAPS"

Transcription

1 BLUEKIT VENTILATION FLAPS 1

2 Horizontal mounting into the shaft/the roof Vertical mounting into the shaft/ the facade EN_BLUEKIT_VENTILATIONFLAPS_

3 Summary New building... 4 Horizontal mounting... 4 Ventilation flap JK-180 HV... 4 Roof vent JK-180 HVC... 6 Roof vent with blades JK-180 HVL... 8 Thermo Flap TF Vertical mounting Ventilation flap with weather protection grilles ALAS.. 12 Insulated Louvre Windows S9iVt-05 LF-MR Tairmo-LF-MR Choosing the best solution for ventilation flaps is determining for ventilation regulation and optimization. They are crucial for the execution of an efficient energetic concept and contribute to the decrease of building operating costs. It is possible to combine to our BlueKit system, Louvre Windows or ventilation flaps which are in accordance with EN certified, together or without protection accessories such as weather protection grilles or roof window. Modernisation Horizontal and vertical mounting JK Horizontal mounting JK-190 Side-corner mounting (accessories)

4 NEW BUILDING Horizontal JK-180 HV CERTIFIED EN after The most efficient solution for new buildings Product Flush installation Easy connection to exterior ventilation shaft Possible combination with roof window Easy installing, easy access to motor To choose from : spring return actuator or direct current Ventilation flap Features : Louvres made of aluminum profile, flowfavouring and torsion-resistant Seals in reinforced rubber Profiled sheet steel frame galvanized 1.5 mm, dimensionally stable Delivered and assembled with profiled mounting plate Pre-assembled and pre-cabled motor : life length certified for cycles Motor cabling with RJ45 connector for easy connection to BlueKit system Motor with positive safety functioning in case of power failure MOUNTING Adjustment in the opening thanks to the mounting plate; possible mounting from outside or from the lift shaft. 4

5 NEW BUILDING Horizontal JK-180 HV Drawings and dimensions MOUNTING FROM THE ROOF Concrete ceiling Concrete ceiling Section B-B Section A-A MOUNTING FROM THE SHAFT Concrete ceiling Concrete ceiling Section B-B Section A-A JK-180 HV Designation according to the ventilation flap opening (mm) BxH 360x x x x x x1200 Net ventilation surface (m 2 ) 0,10 0,23 0,41 0,62 0,90 1,22 Opening dimensions (mm) B1xH1 590x x x x x x1290 Mounting plate dimensions (mm) B2xH2 740x x x x x x1440 5

6 NEW BUILDING Horizontal JK-180 HVC CERTIFIED EN after Optimum insulation and protection under all weather conditions Product Integration to thermal insulation Protection against bad weather Complete and built-in solution Hygienic and energetic optimized Prevents from condensation Ventilation flap and roof vent Features Ventilation flap JK-180 HV (see page 4) Roof vent: Connector base to ventilation flap for flat roof Protects from rain Condensate recovery and evacuation Material: steel galvanized sheet (Ref. JK-180 HVC-S) or aluminum (Ref. JK-180 HVC-A) Thickness: 1,2mm Production: spot welding for the base plate spot welding and riveting for the cover MOUNTING Mounting of the ventilation flap from outside or inside the shaft Integration of the base plate during building insulation* Connection of ventilation flap (reference JK-180 HV) to the base plate thanks to predrilled holes Cover set up *The mounting of the roof vent can easily be done by a roofer but should not be part of the lift professional tasks. 6

7 NEW BUILDING Horizontal JK-180 HVC Section B-B Drawings and dimensions Section A-A Condensate outlet nozzle Flat roof upper layer Roof sealing Thermal insulation Concret ceiling JK-180 HVC Designation according to the ventilation flap opening (mm) BxH 360x x x x x x1200 Net ventilation surface (m 2 ) 0,10 0,23 0,41 0,62 0,90 1,22 Opening dimensions (mm) B1xH1 590x x x x x x1290 Mounting plate dimensions (mm) B2xH2 740x x x x x x1440 Cover dimensions B3xH3 890x x x x x x1790 Base plate height (mm) L1* Cover height (mm) L Overall height of the roof vent (mm) L * other base plate heights available upon request 7

8 NEW BUILDING Horizontal JK-180 HVL Compact solution for optimal insulation and protection CERTIFIED EN after Product Integration to thermal insulation Complete and built-in solution Compact solution: ideal to optimize space Hygienic and energetic optimized Prevents from condensation Ventilation flap and roof vent with blades Features Ventilation flap JK-180 HV (see page 4) Roof vent with blades : Base plate for flat roof with interface to connect ventilation flap Protects from rain Ideal when lack of space : the louvre cover dimensions correspond to the base plate dimensions Condensate recovery and evacuation Material: steel galvanized sheet (Ref. JK-180 HVL-S) or aluminum (Ref. JK-180 HVL-A) Production: spot welding MOUNTING Mounting of the ventilation flap from outside or inside the shaft Integration of the base plate during building insulation* Connection of ventilation flap (reference JK- 180 HV) to the base plate thanks to pre-drilled holes Cover set up *The mounting of the roof vent can easily be done by a roofer but should not be part of the lift professional tasks. 8

9 NEW BUILDING Horizontal JK-180 HVL Section B-B Drawings and dimensions Section A-A Condensate outlet nozzle Flat roof upper layer Roof sealing Thermal insulation Concrete ceiling JK-180 HVL Designation according to the ventilation flap opening (mm) BxH 360x x x x x x1200 Net ventilation surface (m 2 ) 0,10 0,23 0,41 0,62 0,90 1,22 Opening dimensions (mm) B1xH1 590x x x x x x1290 Mounting plate dimensions (mm) B2xH2 740x x x x x x1440 Cover dimensions (mm) B3xH3 690x x x x x x1390 Base plate height (mm) L1* Cover height (mm) L Overall height of the roof vent (mm) L * other base plate heights available upon request 9

10 NEW BUILDING Horizontal TF (Thermo Flap) The all-in-one solution with insulation CERTIFIED EN after Product Integration to thermal insulation Built-in solution Ventilation opening on 4 sides The insulated base plate prevents from condensate Ventilation and smoke extraction assured regardless of wind direction Excellent heat transfer coefficient Base plate in fiberglass (GRP), Louvre windows + cover with blades Features : Base plate in fiberglass combined with a Louvre window Louvre window with electric motor Cover with blades protecting against bad weather and with ventilation on 4 sides Ideal when lack of space : the Louvre cover dimensions correspond to the base plate dimensions Insect-proof Resistant MOUNTING Integration of the base plate during building insulation* MAINTENANCE Visual maintenance from the shaft, easy access from the roof in case of repair. *The mounting of the roof vent can easily be done by a roofer but should not be part of the lift professional tasks. 10

11 NEW BUILDING Horizontal TF (Thermo Flap) Section B-B Drawings and dimensions Section A-A 450x450mm - 1 blade Flat roof upper layer Roof sealing Thermal Insulation 600x600mm - 2 blades Concrete ceiling 800x800mm - 3 blades Designation according to the opening dimensions (mm) BxH TF 450x x x800 Net ventilation surface (m 2 ) 0,10 0,20 0,39 Base plate dimensions (mm) B1xH1 810x x x1160 Cover dimensions (mm) B2xH2 595x x x985 Base plate height (mm) L Cover height (mm) L Thermo Flap overall height (mm) L U-Value (W/m²K) 0,41 0,46 0,55 Number of blades

12 NEW BUILDING Vertical JK-180 HV-ALAS CERTIFIED EN after Vertical ventilation and protection, quite simply! Product Flush installation Integration to the building thermal insulation Easy installation from the shaft or the machine room Ventilation flap with weather protection grille Features Ventilation flap JK-180 HV (see page 4) Weather protection grille ALAS: Ventilation grille with fixed rain-repellent blades preventing the ingress of rain or snow into the ducting system. A grid (fixed behind) protects against intrusion of birds. Blades : galvanised steel Grid : galvanised steel Mounting feet MOUNTING Vertical mounting in the wall shaft or in the machine room. Mounting of the ventilation flap and weather protection grille in the ventilation opening. Mounting from the shaft, thanks to the mounting plate of the ventilation flap and the grille mounting feet. 12

13 NEW BUILDING Vertical JK-180 HV-ALAS Drawings and dimensions Mounting plate B2xH2 Opening dimensions B1xH1 Flap Frame Flap opening BxH Inside Outside Inside Outside Inside view Outside view Section Alternative section JK-180 HV-ALAS Designation according to the ventilation flap opening (mm) BxH 360x x x x x x1200 Net ventilation surface (m 2 ) 0,10 0,23 0,38 0,56 0,77 1,03 Opening dimensions (mm) B1 x H1 590x x x x x x1290 Mounting plate dimensions (mm) B2 x H2 740x x x x x x

14 NEW BUILDING Vertical CERTIFIED EN S9-iVt-05 LF-MR and Tairmo-LF-MR after Combine ventilation, energetic efficiency and modern design Product Flush installation Integration to the building thermal insulation Excellent thermal performance :low coefficient of the glass heat permeability (coef. Ug/Up/Uw) Anti breakage Mounting time reduced S9-iVt-05 Louvre window Features Aluminum profiles, thermally broken Glass blade frame (Tairmo) or sandwich panels* (S9-iVt-05) Air permeability, water tightness and heat protection Anodised/powder coated Double or triple glazing Electric motor: 24VDC Opening angles: Maxi 90 (Tairmo) Maxi 84 (S9-iVt-05) Tairmo *S9-iVt-05 blades available in glass also upon request MOUNTING Vertical flush mounting in the wall shaft. The installation is done from the shaft thanks to mounting feet or a specific mounting plate. 14

15 NEW BUILDING Vertical S9-iVt-05 LF-MR and Tairmo-LF-MR Drawings and dimensions Outside view Inside Section Outside S9-iVt-05 LF-MR D e sig nati on ac cording to the 420x x x x775 element dimensions BxH Net ventilation surface (m 2 ) 0,1 0,15 0,2 0,39 Opening dimensions (mm) B1xH1 450x x x x805 Panel Up-Value (W/m²K) 1,0 1,0 1,0 1,0 Coef. Uw (W/m 2 K) 2,5 2,3 2,3 2,1 Number of blades Outside view Inside Section Outside Tairmo-LF-MR Designation according to the 800x x x x815 element dimensions BxH Net ventilation surface (m 2 ) 0,11 0,15 0,20 0,40 Opening dimensions (mm) B1xH1 830x x x x845 Coef. Ug (W/m 2 K) 0,7 0,7 0,7 0,7 Coef. Uw (W/m 2 K) 1,9 1,8 1,7 1,6 Number of blades

16 MODERNISATION JK-190 Horizontal/Vertical CERTIFIED EN after The flexible solution for modernisations Product Non-integrated solution Surface mounting Do not decrease the ventilation surface Can be adapted to all openings Easy ventilation flap mounting and motor maintenance Ventilation flap Features Louvres made of aluminum profile, flow-favouring and torsion-resistant Seals in reinforced rubber Profiled sheet steel frame galvanized 1.5 mm, dimensionally stable Pre-assembled and pre-cabled motor : life length certified for cycles Motor cabling with RJ45 connector for easy connection to BlueKit system Motor with positive safety functioning in case of power failure The additional 10 mm depth of the frame allows a wider ventilation surface (free movement of the blades and airflow increase between the blades) MOUNTING Fixing in the wall or the lift shaft slab thanks to the mounting frame. On both sides, the ventilation flap openings must be superior by a minimum of 30 mm of the ventilation openings. Installation possible in a corner with a specific mounting angle (sold as an accessory see page 18) 16

17 MODERNISATION JK-190 Horizontal/Vertical Section B-B Drawings and dimensions Section A-A Concrete ceiling Concrete ceiling JK-190* Ventilation flap opening (mm) H/B ,1 0,15 0,2 0,25 0,3 0, ,16 0,23 0,3 0,37 0,45 0, ,21 0,31 0,41 0,5 0,6 0, ,26 0,38 0,51 0,62 0,75 0, ,31 0,46 0,61 0,75 0,9 1, ,37 0,54 0,71 0,87 1,05 1,22 *Standard dimensions in grey 17

18 MODERNISATION Horizontal JK-190 Slab/Corner CERTIFIED EN after Accessories for horizontal mounting Produkt Ventilation flap JK-190 with mounting angles Solution for the ventilation flap mounting in a corner of the shaft slab when space for fixing is not sufficient Ventilation Flap + mounting angles MOUNTING Flexible mounting according to the access to the ventilation opening 3 mounting angles: Fixing of angle corner 1 to the ventilation flap together with the supplied nuts Positioning of the ventilation flap including mounting angle 1 in front of the opening and screwmounting in the shaft slab Positioning of mounting angle 2 on the ventilation flap and screwmounting in the shaft wall

19 MODERNISATION Horizontal JK-190 Slab/Corner Section B-B Drawings and dimensions with mounting angles Section A-A Corner view / shaft headroom

20 FURTHER INFORMATION INTELLIGENT LIFT SHAFT SYSTEMS EUROPE-WIDE AVAILABLE 20

DICTATOR Lift Shaft System

DICTATOR Lift Shaft System DICTATOR Lift Shaft System The Modular Lift Shaft System, also for Retrofitting Certified According to EN 1090 A lift is becoming more and more important for daily life, not only in newly constructed buildings

More information

SECTION SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Doors B. Track and Framing 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.

More information

Efficient cooling in a natural and energy-saving way. Large volume flows of outside air provide cooling. Intelligent control

Efficient cooling in a natural and energy-saving way. Large volume flows of outside air provide cooling. Intelligent control Ventilative cooling NEW Efficient cooling in a natural and energy-saving way Large volume flows of outside air provide cooling Intelligent control No artificial interventions needed (such as air conditioning)

More information

Kingspan Day-Lite Klick

Kingspan Day-Lite Klick Insulated Panel Envelope Systems Roof Wall Façades Lighting Rooftop PV Coldstore Structural Products Cleanrooms UK & Ireland Kingspan Day-Lite Klick Installation Guide Page 2 Accessories Overview Designation

More information

cero by Solarlux cero by Solarlux cero opens rooms with extensive glass panels: impressive transparency dissolves the line between inside and outside. As a brand of Solarlux, the leading supplier in the

More information

Vengen 28. There s a much bigger picture to be found at Ruskin Air Management. Double Glazed Thermal Break Louvre Window. naco.

Vengen 28. There s a much bigger picture to be found at Ruskin Air Management. Double Glazed Thermal Break Louvre Window. naco. August 2013 Vengen 28 Double Glazed Thermal Break Louvre Window l Manual Control l Motor Control l Anti-Finger Trap l Fail Safe Open / Close l Control Panels There s a much bigger picture to be found at

More information

AIRCOOL VENTILATORS FURTHER INFORMATION

AIRCOOL VENTILATORS FURTHER INFORMATION .................................................. CI/SfB (57.7) Xy Uniclass L7563 January 2015 FURTHER INFORMATION................................................................... Services Passivent

More information

7520 Casement Windows

7520 Casement Windows Full casement Single casement Double-bottom casement Double casement FULL DOUBLE CASEMENT - Min 1 9 1 6 Max 3 0 5 0 or 2 6 6 0 CASEMENT W/ PICTURE - Min 4 6 1 6 Max 12 0 6 0 with 30 vent set - Minimum

More information

A. This Section includes ceiling- and wall-mounted diffusers, registers, grilles and louvers.

A. This Section includes ceiling- and wall-mounted diffusers, registers, grilles and louvers. SECTION 23 37 13 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

adaptable 2014 CONCEPT MODULAR PREFAB - MODULI ABITATIVI PREFABBRICATI

adaptable 2014 CONCEPT MODULAR PREFAB - MODULI ABITATIVI PREFABBRICATI The accurate study of the proportions and modularity, led us to design a elementary module from the standard dimensions of around 2,5 x 5,5 x 3 meters. All modules are designed for minimal waste of space

More information

PVC-U: Innovations and product ranges

PVC-U: Innovations and product ranges PVC-U: Innovations and product ranges Be successful with Schüco 4 pillars of success 1 2 3 4 Product innovations Ranges Sales support Marketing Productivity gains Machinery and application technology Speed

More information

Presentation of prefabricated houses. - Main equipments. - Assembly steps. - Some realisations

Presentation of prefabricated houses. - Main equipments. - Assembly steps. - Some realisations Prefabricated Houses Presentation of prefabricated houses - Employed components - Main equipments - Assembly steps - Some realisations SKA spa via Agosta, 3-36066 Sandrigo (VI) - Italy - Tel. + 39 0444

More information

Ordering example: BKI-K90/SFR1.90T/B=1000xH=1000xH=1000xL=250. Standard damper length; special dimensions are available on request

Ordering example: BKI-K90/SFR1.90T/B=1000xH=1000xH=1000xL=250. Standard damper length; special dimensions are available on request Ordering example: Damper BKI-K90/SFR1.90T/B=1000xH=1000xH=1000xL=250 Standard damper length; special dimensions are available on request Dimensions B x H (width x height) in mm, side H = operating side

More information

T O T A L C O M F O R T F O R Y O U R C O N S E R V A T O R Y A I R T O P

T O T A L C O M F O R T F O R Y O U R C O N S E R V A T O R Y A I R T O P T O T A L C O M F O R T F O R Y O U R C O N S E R V A T O R Y AIRTOP HOW TO ACHIEVE A COMFORTABLE LIVING ENVIRONMENT IN YOUR CONSERVATORY? Building a conservatory to provide an extra living room will certainly

More information

GERMAN AMERICAN ENERGY EFFICIENCY CONFERENCE

GERMAN AMERICAN ENERGY EFFICIENCY CONFERENCE GERMAN AMERICAN ENERGY EFFICIENCY CONFERENCE NSHEV, Louvre Windows & Special s Florian Prock Key Account Manager EuroLam GmbH www.eurolam.de Houston, 17.09.2013 About us EuroLam GmbH Date of foundation:

More information

Blast Damper HV PROTECTIVE SHIELD. Features. Protection and Airflow. V00129, D

Blast Damper HV PROTECTIVE SHIELD. Features. Protection and Airflow.  V00129, D Blast Damper HV Protection and Airflow HV Series Blast Damper is designed to protect personnel and critical equipment against blast wave created by explosion in industrial facility. Gas explosions occur

More information

INDUSTRIALIZED CONSTRUCTION BRASILIT FIBER CEMENT BOARD, PANELS AND ACCESSORIES FOR THE EXECUTION OF YOUR CONSTRUCTION

INDUSTRIALIZED CONSTRUCTION BRASILIT FIBER CEMENT BOARD, PANELS AND ACCESSORIES FOR THE EXECUTION OF YOUR CONSTRUCTION INDUSTRIALIZED CONSTRUCTION BRASILIT FIBER CEMENT BOARD, PANELS AND ACCESSORIES FOR THE EXECUTION OF YOUR CONSTRUCTION Make it Easier with Brasilit BRASILIT FIBER CEMENT BOARDS AND PANELS. QUICKNESS AND

More information

CASSETTE BS Specification book

CASSETTE BS Specification book CASSETTE BS Specification book Edition: April 2011 ArcelorMittal Construction International Industriestrasse 19 8112 Otelfingen / Zürich Switzerland www.arcelormittal.com/arval PRESENTATION OF THE SYSTEM

More information

DESIGN / MANUFACTURING / DISTRIBUTION / INSTALLATION / RENOVATION / MAINTENANCE / REPAIRING

DESIGN / MANUFACTURING / DISTRIBUTION / INSTALLATION / RENOVATION / MAINTENANCE / REPAIRING Natural daylighting, ventilation & smoke Exhaust EXCLUSIVE Very descreet electrical opening motor ECOVISION EL Façade opening frame for smoke exhaust and natural ventilation with electrical control system

More information

UL, KUL, WG-KUL, ARK, ARK-1

UL, KUL, WG-KUL, ARK, ARK-1 Installation manual GB/en Non-return dampers Types UL, KUL, WG-KUL, ARK, ARK-1 TROX GmbH Heinrich-Trox-Platz 47504 Neukirchen-Vluyn Germany Phone: +49 (0) 2845 2020 Fax: +49 (0) 2845 202265 E-mail: trox@trox.de

More information

SECTION EXTERIOR GRILLS AND SCREENS

SECTION EXTERIOR GRILLS AND SCREENS SECTION 10 82 13 PART 1 GENERAL PART 1 1 SUMMARY A. Section Includes: 1. Exterior perforated aluminum screen wall system with Ombrae TM Optical Tile imaging technology. 2. Accessories including attachments,

More information

SWING DOOR SPECIFICATION

SWING DOOR SPECIFICATION SWING DOOR A1 Work included: Furnish all necessary materials, labour and equipment for the complete installation of aluminum entrance doors, door frames and hardware as detailed on the drawings and specified

More information

Smoke Control Damper ESAM Instructions for installation, operation and maintenance 10/2014

Smoke Control Damper ESAM Instructions for installation, operation and maintenance 10/2014 Instructions for installation, operation and maintenance 0/204 General The rectangular smoke control damper ESAM is specially designed for use in multi fire-compartment applications as a closing or opening

More information

Series - 1

Series - 1 SECTION 08360 SECTIONAL OVERHEAD DOORS 591 SERIES THERMACORE INSULATED STEEL DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click

More information

Fire protection, soundproofing and thermal insulation

Fire protection, soundproofing and thermal insulation ROMA INSULATION SYSTEMS Fire protection, soundproofing and thermal insulation Quick-assembly insulating panel, types FP, FV and FP Acoustic 02 ROMA quick-assembly insulating panel, types FP and FP+ Cladding

More information

Power Zone Center. Your solution for power distribution and control systems

Power Zone Center. Your solution for power distribution and control systems Power Zone Center Your solution for power distribution and control systems The Strength of One Powerful When you need to install a new power distribution center in your facility, you need it done in fastest

More information

RUUKKI FORMA DESIGN INSTRUCTION

RUUKKI FORMA DESIGN INSTRUCTION www.ruukki.com RUUKKI FORMA DESIGN INSTRUCTION 1. General Ruukki Forma is a complete façade system in which Ruukki energy panels form an energy efficient base structure and Ruukki cladding products finalize

More information

Page 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES

Page 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES 2016-03-24 Page 1 SECTION 08360 SECTIONAL OVERHEAD DOORS DESCRIPTION MODEL 900 PRODUCT FEATURES Sectional steel overhead doors, industrial grade heavy duty construction. BASIC USES / RELATED USES Sectional

More information

Construction Report NYSERDA Residential Performance Challenge

Construction Report NYSERDA Residential Performance Challenge Construction Report NYSERDA Residential Performance Challenge WELYTOK TOWNHOMES October 2014 Submitted to: NYSERDA 17 Columbia Circle Albany, NY 12203 Submitted by: HOMEPIC Team CDH Energy Corp. PO Box

More information

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.

More information

mounting systems applications overview

mounting systems applications overview mounting systems applications overview catalogue version January 2015 tritec mounting systems: overview of applications i. pitched roof: roof-top 1. Tiles, shingles and corrugated panels 1.1 TRI-STAND

More information

COMP ONENT CATA LO GUE FOR INDUSTRIAL BUILDINGS

COMP ONENT CATA LO GUE FOR INDUSTRIAL BUILDINGS M a d e f o r b u i l d i n g b u i l t f o r l i v i n g COMP ONENT CATA LO GUE FOR INDUSTRIAL BUILDINGS I M P R i n t KLH Massivholz GmbH Publisher and responsible for the content: KLH Massivholz GmbH

More information

Corium Brick Rainscreen System Specifications

Corium Brick Rainscreen System Specifications CORIUM BRICK RAINSCREEN SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Work Included: The Work of this Section shall include but not be limited to the following: 1. Corium brick plates 2. Galvanized and coated

More information

Product information Roof terrace GEL + VEA/VEB/VEC

Product information Roof terrace GEL + VEA/VEB/VEC Edition 1.0 01.07.2015 Product information Roof terrace GEL + VEA/VEB/VEC Product description High quality natural pinewood coated with impregnation and layers of water-based acrylic clear lacquer or white

More information

General Conditions 39,522 5, ,292 26,050 75,921 1, Labor hours

General Conditions 39,522 5, ,292 26,050 75,921 1, Labor hours Basic Edition Standard Estimate Report Page 1 Name 1000 General Conditions 1107 Professional Consultant 10 Surveying 1.00 day 600.000 /day 600 - - - - - - 600 Professional Consultant 600 600 8.00 hours

More information

Vertigo Cladding Board

Vertigo Cladding Board Installation guide Vertigo Cladding Board Geolam: a stunning alternative to wood cladding Vertigo is a composite wood cladding board requiring minimum maintenance. Durable and fade resistant, it will not

More information

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how? SECTION 08360 SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Glazed Aluminum

More information

Product information Centre-pivot white-painted roof window GGL

Product information Centre-pivot white-painted roof window GGL Edition 2.0 13.09.2017 Product information Centre-pivot white-painted roof window Product description High quality natural pinewood coated with impregnation and layers of water-based acrylic white paint

More information

ASSEMBLY INSTRUCTION TG 2002

ASSEMBLY INSTRUCTION TG 2002 ASSEMBLY INSTRUCTION Hunton Windtight 12 TG 2002 HUNTOIN Windtight Storage Windtight panels must be stored dry and be dry when fitted. Before fitting, the panels should be conditioned where necessary so

More information

GIESSE OPEN SOURCE SYSTEM CASEMENT PROFILES SYSTEM FOR WINDOWS AND DOORS CASEMENT

GIESSE OPEN SOURCE SYSTEM CASEMENT PROFILES SYSTEM FOR WINDOWS AND DOORS CASEMENT GIESSE OPEN SOURCE SYSTEM CASEMENT PROFILES SYSTEM FOR WINDOWS AND DOORS CASEMENT GOS-C SYSTEM THE ITALIAN DESIGN met the best European technology for the construction of windows and doors sashes. GOS-C

More information

Leak Tightness of Jointing. 1. Basic Principles

Leak Tightness of Jointing. 1. Basic Principles Leak Tightness of Jointing a) Fischer roof element low pressure box 28th November 2000 low pressure on corrugated side L = Rota tube L1/50-8623 n = 2 Pressure Airflow Airflow Brandenburg Technical University

More information

Installation instruction

Installation instruction Installation instruction Ci51 www.contura.eu 114 CERTIFICATE Declaration of performance according to Regulation (EU) 305/2011 No. Ci51-CPR-150821-SE-2 PRODUCT Product type Type designation Manufacturing

More information

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K T Premium Panel, protection category IP 69K IP 69 K.6 H H H Optionally with or without keyboard housing Resistant to high-pressure cleaning (protection category IP 69K). The seal lies between two surfaces

More information

Guide Specifications for Prodema PRODEX External Cladding

Guide Specifications for Prodema PRODEX External Cladding Guide Specifications for Prodema PRODEX External Cladding SECTION 07420 Exterior Wall Cladding Note: These specifications were current at the time of publication but are subject to change at any time without

More information

1.1.2 All window frames will be Kite marked to indicate compliance with these standards.

1.1.2 All window frames will be Kite marked to indicate compliance with these standards. PVC-u WINDOWS Specification 1.1 General Spcification 1.1.1 All products supplied will fully comply with current editions of all relevant British Standards and Codes of Practice, and in particular all profiles

More information

Section BUILDINGS, SHELTERS, ENCLOSURES

Section BUILDINGS, SHELTERS, ENCLOSURES Section 13121 BUILDINGS, SHELTERS, ENCLOSURES Part 1 GENERAL 1.1 SECTION INCLUDES 1.2 A. Pre-engineered buildings. B. Pre-engineered shelters. C. Pre-engineered enclosures. D. Electrical wiring and devices

More information

DIVISION 04 MASONRY CAST STONE. A. Design Considerations. 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone.

DIVISION 04 MASONRY CAST STONE. A. Design Considerations. 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone. DIVISION 04 MASONRY 04720 CAST STONE A. Design Considerations 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone. 2. Care must be taken in the design of individual units

More information

One and Two Family Additions

One and Two Family Additions One and Two Family Additions An addition to a house, duplex, garage, or an accessory structure requires a building permit prior to performing any construction. Building Department & Permit Office Mon-Fri

More information

GRAIN STORAGE SYSTEMS

GRAIN STORAGE SYSTEMS GRAIN STORAGE SYSTEMS FOPRO Grain Systems is a market leader in the design and manufacture of grain storage silo and handling systems. FOPRO has earned an excellent reputation worldwide with superior system

More information

ArcelorMittal Europe - Long Products Sections and Merchant Bars. Office Building ArcelorMittal in Esch Alzette

ArcelorMittal Europe - Long Products Sections and Merchant Bars. Office Building ArcelorMittal in Esch Alzette ArcelorMittal Europe - Long Products Sections and Merchant Bars Office Building ArcelorMittal in Esch Alzette Location the country, at the heart of the iron and steel region. It has good access to the

More information

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS SECTION 270528 PATHWAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Communications equipment coordination and installation. 2. Sleeves for pathways and cables. 3. Raceway

More information

Product information Roof balcony CABRIO GDL

Product information Roof balcony CABRIO GDL Edition 2.0 01.04.2016 Product information Roof balcony CABRIO GDL Product description High quality natural pinewood coated with impregnation and layers of water-based acrylic white paint or clear lacquer

More information

WEEDOO - SA CONSTRUCTION TECHNOLOGY

WEEDOO - SA CONSTRUCTION TECHNOLOGY Advantages of Double Glazed upvc Windows & Doors WEEDOO SA Technical Support by Jason Jorgensen Advantages of upvc Windows and Doors Heat and Cold insulation Sound insulation Water tightness Dust proof

More information

6110 Horizontal Sliding Windows

6110 Horizontal Sliding Windows 6110 Horizontal Sliding Windows Half-vent Half-vent below Half-vent above Single-vent HALF-VENT - Min 2 0 1 0 Max 6 0 5 0 HALF-VENT ABVE - Min 2 0 2 0 Max 6 0 6 0 HALF-VENT BELW - Min 2 0 2 0 Max 6 0 6

More information

The Alternative to Storefront. Gerkin Model 58F

The Alternative to Storefront. Gerkin Model 58F The Alternative to Storefront Gerkin Model 58F Why do we need an alternative? To provide windows with factory glazing To eliminate water leaks To eliminate the need for sill flashing w/ end dams To reduce

More information

HOME & BUSINESS IMPROVEMENTS BE CLEVER... BE SAFE... BROCHURE 2017

HOME & BUSINESS IMPROVEMENTS BE CLEVER... BE SAFE...  BROCHURE 2017 HOME & BUSINESS IMPROVEMENTS BE CLEVER... BE SAFE... COMPOSITE STEEL DOORS GERMAN VEKA PVC / ALUMINIUM WINDOWS & DOORS INSULATED SECURITY SHUTTERS GARAGE DOORS RETRACTABLE GRILLES SUN PROTECTION WINDOW

More information

MODEL: SIGHT-LINE- COMMAND CENTER CONSOLES

MODEL: SIGHT-LINE- COMMAND CENTER CONSOLES 2015 WINSTED CORPORATION 1) GENERAL DESCRIPTION 1.1 Sight-Line Command Center Consoles. SeeAppendix A - C for typical styles and measurements. 1.2 The contractor shall supply a system capable of supporting

More information

Domes Pyramids Opening Rooflights Flatglass Rooflights

Domes Pyramids Opening Rooflights Flatglass Rooflights Domes Pyramids Opening Rooflights Flatglass Rooflights The Roofglaze range of modular rooflights offers a huge variety of solutions for introducing natural light into all kinds of buildings, with options

More information

Vinyl Windows and Doors

Vinyl Windows and Doors Install Atrium 0UZ[PSS *VUÄKLUJL Vinyl Windows and Doors Atrium Vinyl Windows A Commitment to Excellence Since 1948 Welcome the beauty of The Vinyl Advantage Vinyl is the ideal material for engineering

More information

NASSAU Panorama. Showrooms. NASSAU Panorama 4.1. You know the Quality

NASSAU Panorama. Showrooms. NASSAU Panorama 4.1. You know the Quality 4.1 Showrooms has been designed specially for buildings where a lot of natural light is required, as the windows do not have any vertical bars. The door appears elegant with its clean lines and lets lots

More information

ifix INSTALLATION MANUAL PV flat roof installation system Version

ifix INSTALLATION MANUAL PV flat roof installation system Version ifix PV flat roof installation system INSTALLATION MANUAL Version 2012-09-06 ifix Installation Manual Version 2012-09-06 Seite 1 Table of contents Table of contents... 1 Special characteristics of ifix...

More information

More space, more light, a better quality of life: The high insulated folding sliding doors from Schweizer.

More space, more light, a better quality of life: The high insulated folding sliding doors from Schweizer. More space, more light, a better quality of life: The high insulated folding sliding doors from Schweizer. 2 An easy perspective: Folding sliding doors enable greater transparency. Whether for a modern

More information

SECTION HVAC GRAVITY VENTILATORS

SECTION HVAC GRAVITY VENTILATORS SECTION 23 37 23 HVAC GRAVITY VENTILATORS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Sculpted 3D Minimal. Rain Screen Wall System

Sculpted 3D Minimal. Rain Screen Wall System Sculpted 3D Minimal Rain Screen Wall System Metalwërks Sculpted frees designers to create iconic facades more easily and affordably than ever before by elevating three-dimensional wall panels to entirely

More information

ON-ROOF ATTACHMENT FLAT COLLECTOR HELIOSTAR

ON-ROOF ATTACHMENT FLAT COLLECTOR HELIOSTAR ON-ROOF ATTACHMENT FLAT COLLECTOR HELIOSTAR INSTALLATION INSTRUCTIONS ENERGY AND SANITARY SYSTEMS Installation requirements Generel requirements The on-roof attachment set is capable for installation of

More information

DIVISION 13 - SPECIAL CONSTRUCTION SECTION ACOUSTICAL PANEL ENCLOSURE

DIVISION 13 - SPECIAL CONSTRUCTION SECTION ACOUSTICAL PANEL ENCLOSURE DIVISION 13 - SPECIAL CONSTRUCTION SECTION 13080 - ACOUSTICAL PANEL ENCLOSURE 1 GENERAL 1.01 SUMMARY A. ACOUSTIC ENCLOSURE CONSISTING OF WALLS, CEILING, STRUCTURAL FRAMING, CONNECTING MEMBERS, DOORS, WINDOWS,

More information

MASCARET Implementation Guide

MASCARET Implementation Guide MASCARET Implementation Guide Edition of August 21st, 2007 PMA by Arval ZA du Pays de Podensac 33720 CERONS - France Tel. +33 (0)5.57.98.14.50 Fax. +33 (0)5.57.98.14.60 commercial@pma.fr www.pma.fr -2-

More information

RS24-10 Single-Section Skylight System

RS24-10 Single-Section Skylight System INSTALLATION INSTRUCTIONS RS24-10 VERSION 1.100316 DATED: 10/03/16 RS24-10 Single-Section Skylight System under/over seam clip double diverter US Patent D750,282 www.rnssales.com sales@rnssales.com 805.375.3980

More information

CLCF Climate Changer for comfort applications. Next generation air handling performance from Trane

CLCF Climate Changer for comfort applications. Next generation air handling performance from Trane CLCF Climate Changer for comfort applications Next generation air handling performance from Trane Customized performance and maximum comfort at minimum cost For many years Trane has been a global leader

More information

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows: SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.

More information

THERMALLY BROKEN ALUMINUM SERIES

THERMALLY BROKEN ALUMINUM SERIES THERMALLY BROKEN ALUMINUM SERIES PRODUCT OVERVIEW DYNAMIC ARCHITECTURAL MANUFACTURES TWO DESIGNS OF THERMALLY BROKEN WINDOWS AND DOORS. The Reynaers window door system is one of Europe s most established

More information

Fire Prevention K90 and K30 dampers in accordance with DIN Part I 09/2006

Fire Prevention K90 and K30 dampers in accordance with DIN Part I 09/2006 Fire Prevention K90 and K30 dampers in accordance with DIN 4102-6 Part I 09/2006 40 30 20 50 L W db(a) 45 L W db(a) Total pressure loss pt [Pa] 10 6 4 35 L W db(a) 2 400 600 800 1000 1400 2000 2600. Volume

More information

Product information Vertical window element VFE

Product information Vertical window element VFE Edition 2.0 01.01.2017 Product information Vertical window element Product description High quality natural pinewood coated with impregnation and layers of water-based white paint or acrylic clear lacquer

More information

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

SECTION BASIC ELECTRICAL MATERIALS AND METHODS SECTION 26 05 05 BASIC ELECTRICAL MATERIALS PART 1 - GENERAL 1.1 SUMMARY A. Section includes the limited scope construction materials and methods for application with electrical installations as follows:

More information

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Part 1 General 1. RELATED SECTIONS 1. Section 07 92 10 Joint Sealing 2. Section 08 71 00 Door Hardware 2. REFERENCES 1. American Society

More information

Dynamic Bonding Systems B.V. A division of Dutch Bonding Group B.V.

Dynamic Bonding Systems B.V. A division of Dutch Bonding Group B.V. for the bonding of facade cladding with KOMO-certified bonding system Dynamic Bond METALS - HPL - FIBRECEMENT Dynamic Bond For panels up to the maximum diagonal. Based on MS-hybrid-polymers, one component.

More information

The more intelligent way to insulate: Thermix TX.N plus Warm edge spacers for insulating glass

The more intelligent way to insulate: Thermix TX.N plus Warm edge spacers for insulating glass www.thermix.de The more intelligent way to insulate: Thermix TX.N plus Warm edge spacers for insulating glass Thermix TX.N plus this is warm edge 2 Thermix TX.N plus our best warm edge ever Thermix warm

More information

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM 1 GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials, and services to furnish and install VERSA SHIELD Window

More information

Series - 1

Series - 1 SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word

More information

Fusion Welded, Maintenance Free, All Vinyl Frame and Sash Construction Energy Efficient ¾ Insulated Glass Standard Available Sizes: (Tip to Tip Frame

Fusion Welded, Maintenance Free, All Vinyl Frame and Sash Construction Energy Efficient ¾ Insulated Glass Standard Available Sizes: (Tip to Tip Frame Aristoclass Hopper Vinyl Basement Window: Energy Efficient ¾ Insulated Glass Standard 32 1/8 x 15 1/4 32 1/8 x 19 1/4 32 1/8 x 23 1/4 Main-frame Thickness: 3 1/4 True Sloped Sill for Efficient Water Removal

More information

Products PVC-ALU-WOOD

Products PVC-ALU-WOOD ducts PVC-ALU-WOOD Products PVC-ALU-WOOD Products PVC-ALU-WOOD Products PVC-ALU-WOOD Products PVC-ALU-WOOD Products PVC-A Products PVC-ALU-WOOD PVC PROFILES Ideal 4000 02 5 chamber system 70 mm depth Uw

More information

11/2 HOUR UL CLASSIFIED CURTAIN TYPE (D)IBD2, (D)IBD2SS AND IBDT FIRE DAMPERS

11/2 HOUR UL CLASSIFIED CURTAIN TYPE (D)IBD2, (D)IBD2SS AND IBDT FIRE DAMPERS 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 INSTALLATION INSTRUCTIONS 11/2 HOUR UL CLASSIFIED CURTAIN TYPE (D)IBD2, (D)IBD2SS AND IBDT FIRE DAMPERS APPLICATION The fire

More information

Administrative Changes

Administrative Changes Revised 11/29/06 Knox County Residential Building Codes Significant Changes From The 1995 CABO One And Two Family Dwelling Code To The 2006 International Residential Code All one and two family dwellings

More information

GREENHOUSE ENGINEERING PREFABRICATED HOUSES

GREENHOUSE ENGINEERING PREFABRICATED HOUSES GREENHOUSE ENGINEERING PREFABRICATED HOUSES WOODEN HOUSES Prefabricated wooden houses are made of wooden bearing structure with mineral wool, with a vapor barrier. On the inside, construction is lining

More information

High Performance. System THE BEST WINDOWS ARE MADE FROM PROFILE 22

High Performance. System THE BEST WINDOWS ARE MADE FROM PROFILE 22 High Performance High Curtain Performance Wall Curtain System Wall System THE BEST WINDOWS ARE MADE FROM PROFILE 22 High Performance Curtain Wall System The Best Windows Are Made From Profile 22 As part

More information

BAY POLES FOR LOAD BEARING WINDOWS

BAY POLES FOR LOAD BEARING WINDOWS BAY POLES FOR LOAD BEARING WINDOWS From Nicholls & Cooke The Pole Calculations Ordering Head and Base Plates New Build Box Support Anti Bounce Bars Universal Poles Slack Adjuster Kits Deceurninck Series

More information

ALUMINIUM SAND TRAP LOUVER : CONSTRUCTION

ALUMINIUM SAND TRAP LOUVER : CONSTRUCTION ALUMINIUM SAND TRAP LOUVER : CONSTRUCTION RUSKIN sand trap louvers are specially designed to separated the sand and dust from the air. It is effective and necessary to apply for ventilations and inlet

More information

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets Seismic Frame Two-Post Rack Page 11-3 Seismic Protection Products - Racks Page 11-6 Seismic Protection Products - Runway Page 11-8 Seismic

More information

Planning and installation instructions

Planning and installation instructions Planning and installation instructions Stofix Oy Ahlmaninkatu 2 E 40100 Jyväskylä Finland stofixgroup@stofix.com www.stofix.com 2 PLANNING AND INSTALLATION INSTRUCTIONS... 1 1 General... 3 2 Project Design...

More information

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.

More information

Sound-absorbing and sound-insulating barriers

Sound-absorbing and sound-insulating barriers Sound-absorbing and sound-insulating barriers innovative and biocompatible solutions for the environment sound-insulation Sound-absorbing and sound-insulating noise barriers for road and rail traffic are

More information

TC Series. Commercial Sectional TC Series

TC Series. Commercial Sectional TC Series Commercial Sectional TC Series TC Series Thermal Sectional Doors With a proven track record for thermal efficiency and extreme durability, Raynor TC Series is simply the best you can specify. With extruded

More information

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017 SECTION 10505 - METAL STUDENT LOCKERS PART 1 - GENERAL 1.01 SCOPE OF WORK A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SERIES DESCRIPTION MODEL PAGE

SERIES DESCRIPTION MODEL PAGE Storm Window Index Exterior storm window features increased durability and ultimate thermal protection. Performance Exterior storm window offers more standard features than other storm windows on the market.

More information

Protan Exposed Membrane Roof. Your design - Our solution

Protan Exposed Membrane Roof. Your design - Our solution Protan Exposed Membrane Roof Your design - Our solution Exposed membrane roof The principle function of a roof is to provide durable protection against the external environment to a building. Unprotected

More information

AEROFOILS 200AF-450AF. Sun Control Systems

AEROFOILS 200AF-450AF.  Sun Control Systems AEROFOILS 200AF-450AF www.luxalon.com Sun Control Systems Luxalon Aerofoils 200AF - 450AF System Description Luxalon wing-shaped panel elements, or fins, combine optimum solar effectiveness with a firm

More information

innovation, integration, inspiration High Performance Rainproof Ventilation Louvres

innovation, integration, inspiration High Performance Rainproof Ventilation Louvres innovation, integration, inspiration High Performance Rainproof Ventilation Louvres Rainproof Ventilation Louvres Single and Double Bank Ventilation Louvres - Beijing MRT, Daxing Line Mega Union maintains

More information

Fire Protection Valves

Fire Protection Valves 4/4/EN/6 Fire Protection Valves Type FV-K90 FVZ-K30 with German Test Certificate (General Building Approval) Z-41.3-317 Z-41.3-319 TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/202-265 Heinrich-Trox-Platz

More information

Building Design Data

Building Design Data Building Design Data.. 1. Building Design The KORE ICF System is designed to meet the requirements of the Building Regulations 1997-2006, in the case of two storeys, single occupancy dwellings. If the

More information

Power Electronics, Inc. Packaged Equipment Center Standard Construction and Design Features

Power Electronics, Inc. Packaged Equipment Center Standard Construction and Design Features DESIGN CRITERIA FOR STANDARD CONSTRUCTION: These standard design elements of the P.E.I. Power Equipment Center are utilized to meet the following design criteria per ASCE 7-05 as adopted by the IBC (International

More information