SUBMITTAL INDEX. Product Datasheets: Product Approvals:

Size: px
Start display at page:

Download "SUBMITTAL INDEX. Product Datasheets: Product Approvals:"

Transcription

1 Product Datasheets: HFP Pro Series Sleeve RevA HFP CD Plates RevA HFP Sleeve Extenions RevA HFP Water Dam RevA HFP Water Module RevA HFP Hollow Sleeve RevB HFP Cable Line Set RevA HFP Closet Flange RevA HFP Floor Drain Sleeve RevA HF Hydromount Drain Stand Kit RevG2 HFP Shower Drain Sleeve RevA HF Shower Drain Sleeve RevH HFP Tub Box RevA Product Approvals: SUBMITTAL INDEX XHEZ.F-A-1133, XHEZ.F-A-5043, XHEZ.F-A-1122, XHEZ.F-A-0026, XHEZ.F-A-3052, XHEZ.F-A-1109, XHEZ.F-A-2189, XHEZ.F-A-1111, XHEZ.F-A-8034, XHEZ.F-A-2190, XHEZ.F-B-1018, XHEZ.F-A-1103, XHEZ.F-B-2043, XHEZ.F-A

2

3 Cap & Locator Whiskers PRODUCT SPECIFICATION DRAWING Hydroflame Pro Series Sleeves * See Dim "C" (Telescoping) CD Plate (optional) Safety Cap & Locator Whiskers Included (Shown with optional CD Plate) (OSHA Compliant Hole Cover) * Note: Height range: 2-1/2" to 12". Height range: 2-1/2" to 7-3/4" ("-B" version). Both standard & "-B" style can be extended by adding sleeving extension. Sleeves with black Bases & black Locator Whiskers are for use with metallic penetrants. Sleeve with red Bases & red Locator Whiskers are for use with either metallic or non-metallic (plastic) penetrants. The use of the Locator Whiskers is optional. See Dim "B" See Dim "A" * 7-3/4" Non-Telescoping Version ("-B") The HOLDRITE Hydroflame Pro Series Sleeving System consists of UL & cul listed assemblies that provide sleeving & firestop solutions for cast-in-place concrete floors. These sleeve products provide solutions for both metallic & non-metallic pipes, line-sets, cables, conduits, floor drains, tub drains, shower drains and toilet drains. For slabs 2 ½" and thicker and for pipes, conduits & cables ½" - 6" nominal; 2 & 3 hour UL Fire Ratings and T, L & W- ratings available. 50 Pa ratings available. See UL Fire Resistive Directory (R25101) for further details. Sleeves are easly adapted for use on Corrugated Metal Decking with the use of HoldRite's CD Plates. 16 models include: #HFP-P/M1 (B), #HFP-P/M2 (B), #HFP-P/M3 (B), #HFP-P/M4 (B) and #HFP-P/M6 (B). Product Information: Material: Main Sleeve Body & Safety Cap: Polypropylene Mid-Body Seal: Thermal Plastic Rubber (TPR); Mold & Fungus resistant per ASTM G-21. Locator Whiskers: Nylon Fire Ring: 24GA CRS Firestop Material: UL Listed Intumescent Composite Patented & Patents Pending See Hydroflame Pro Series Installation Instructions, Best Practices documents and the lastest UL Fire Resistive Directory file (R25101) for details. THIS INFORMATION IS PROPRIETARY TO HOLDRITE AND IS SUBJECT TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION OR / FAX: / spec_hfp Series, pg1 of 12_RevA

4 10/19/2016 XHEZ.F A 1133 Through penetration Firestop Systems System No. F A 1133 XHEZ.F A 1133 Through penetration Firestop Systems Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ Through penetration Firestop Systems XHEZ7 Through penetration Firestop Systems Certified for Canada See General Information for Through penetration Firestop Systems See General Information for Through penetration Firestop Systems Certified for Canada System No. F A 1133 September 12, 2016 ANSI/UL1479 (ASTM E814) CAN/ULC S115 F Ratings 2 and 3 Hr (See Item 6) F Ratings 2 and 3 Hr (See Item 6) T Rating 0 Hr L Rating At Ambient Less Than 1 CFM/sq ft L Rating At 400 F Less Than 1 CFM/sq ft W Rating Class 1 (See Item 5) FT Rating 0 Hr FH Rating 3 Hr FTH Rating 0 Hr L Rating At Ambient Less Than 1 CFM/sq ft L Rating At 400 F Less Than 1 CFM/sq ft bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 1133&ccnshorttitle=Through penetration+firestop+systems 1/4

5 10/19/2016 XHEZ.F A 1133 Through penetration Firestop Systems Configuration A Configuration B System tested with a pressure differential of 2.5 Pa between the exposed and the unexposed surfaces with the higher pressure on the exposed side. 1. Floor Assembly The fire rated concrete and fluted steel deck floor assembly shall be constructed of the materials and in the manner specified in the individual D900 Series designs in the UL Fire Resistance Directory and as bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 1133&ccnshorttitle=Through penetration+firestop+systems 2/4

6 10/19/2016 XHEZ.F A 1133 Through penetration Firestop Systems summarized below: A. Concrete Min 2 1/2 in. (64 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete topping, as measured over crests of fluted floor units and over top of device base. B. Steel Floor and Form Units* Composite or noncomposite nom 3 in. (76 mm) deep fluted galv units as specified in the individual Floor Ceiling design. Diam of opening cut through fluted floor unit to be maximum 1/4 in. (6 mm) larger than outside diameter of bottom extension portion of firestop device base. 1A. Floor Assembly Min 4 1/2 in. (114 mm) thick reinforced lightweight or normal weight pcf ( kg/m 3 ) concrete. Measured over the top of the device base. Configuration A 2. Firestop Device* Cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. The device shall be installed flush with top and bottom surfaces of floor. A HFP devices and optional accessories (not shown) includes sleeve extension, water module, deck adapter, aerator adapter and/or water dam installed in accordance with installation instructions. The devices are sized to accommodate the following nom pipe sizes: Nom Pipe Diam in. (mm) Firestop Devices for Concrete Slab Firestop Devices for Fluted Deck (Not Shown) 1/2 to 1 (13 to 25) HFP M1, HFP M1B, HFP P1, HFP P1B add HFPCD1 1 1/4 to 2 (32 to 51) HF M2, HFP M2B, HFP P2, HFP P2B add HFPCD2 2 to 3 (51 to 76) HFP M3, HFP M3B, HFP P3, HFP P3B 3 to 4 (76 to 102) HFP M4, HFP M4B, HFP P4, HFP P4B 5 to 6 (127 to 152) HFP M6, HFP M6B, HFP P6, HFP P6B add HFPCD3 add HFPCD4 add HFPCD6 SECURUS INC, DBA HOLDRITE HydroFlame HFP Mx, HFP MxB, HFP Px HFP PxB Configuration B 2. Firestop Device* Cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. The device shall be installed flush with top and bottom surfaces of floor. Optional accessory (not shown) aerator adapter installed in accordance with the installation instructions. The devices are sized to accommodate the following nom pipe sizes Nom Pipe Diam in. (mm) 1/2 to 1 (13 to 25) 1 1/4 to 2 (32 to 51) Firestop Devices for Concrete Slab CD PL 0100, CD OPS PL 0100, CD OPS MT 0100 CD PL 0200, CD OPS PL 0200, CD OPS MT 0200 Firestop Devices for Fluted Deck (Not Shown) WD PL 0100, OPS PL 0100, OPS MT 0100 WD PL 0200, OPS PL 0200, OPS MT to 3 (51 to 76) CD PL 0300, CD OPS PL 0300, CD OPS MT to 4 (76 to 102) CD PL 0400, CD OPS PL 0400, CD OPS MT 0400 WD PL 0300, OPS PL 0300, OPS MT 0300 WD PL 0400, OPS PL 0400, OPS MT to 6 (127 to 152) CD PL 0600, CD OPS PL 0600, CD OPS MT 0600 WD PL 0600, OPS PL 0600, OPS MT 0600 SECURUS INC, DBA HOLDRITE HydroFlame CD OPS MT, CD PL, CD OPS PL,WD PL, OPS PL, OPS MT 3. Through Penetrant One metallic pipe, conduit or tubing to be installed within the firestop device. Pipe, conduit or tubing to be installed in accordance with firestop device installation instructions and rigidly supported on both sides of floor assembly. The following types of pipe, conduit or tubing may be used: A. Steel Pipe Nom 6 in. (152 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe Nom 6 in. (152 mm) diam (or smaller) cast or ductile iron pipe. C. Conduit Nom 6 in. (152 mm) diam (or smaller) rigid steel conduit or nom 4 in. (102 mm) diam steel electrical metallic tubing. bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 1133&ccnshorttitle=Through penetration+firestop+systems 3/4

7 10/19/2016 XHEZ.F A 1133 Through penetration Firestop Systems D. Copper Tubing Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing. E. Copper Pipe Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. 4. Packing Material (Optional. Not Shown) Min 2 in. (51 mm) depth of min 4 pcf (64 kg/m 3 ) mineral wool batt insulation tightly packed into annular space between penetrant and device, flush with the top surface of the floor. When optional sealant (Item 5) is used, top surface of packing material to be recessed min 1/4 in. (6 mm) from top surface of floor. 4A. Packing Material (Optional instead of 4, Not Shown) Foam backer rod firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor as required to accommodate the required thickness of fill material. 5. Fill, Void or Cavity Material* Sealant (Optional, Not Shown) Min 1/4 in. (6 mm) thickness of sealant applied within the annulus, flush with the top surface of floor. Conf B (Only), Sealant to lap min 1/2 in. (13 mm) onto top surface of concrete around perimeter of firestop device. As an alternate 100% silicone sealant can be used. For Configuration B, The L Rating and W Rating applies only when packing material (Item 4) and sealant (Item 5) is used. 3M COMPANY 3M FIRE PROTECTION PRODUCTS FB 1000 NS, FB 3000 WT or FB 1003 SL RECTORSEAL Metacaulk 835+ or Biotherm 100 or Pipe Tee Fitting System (Optional, Not Shown) For use with Iron Pipe (Item 3B) only, One nom 6 in. (152 mm) diam (or smaller) PVC TESTRITE TEE Fitting (matched to penetrant diameter). The PVC TESTRITE TEE Fitting is secured to metallic penetrant (Item 3B) with compression type pipe coupling elastomeric gasket with stainless steel jacket and stainless steel band clamps for use in vented (drain, waste or vent) iron pipe systems. Installed (Item 3B) penetrant shall extend a minimum of 6 in. (152 mm) above the surface of the floor and minimum 12 in. (302 mm) below the bottom surface of the floor above assembly. When Item 6 is used within 24 in. (610 mm) of the device (Item 2) the F rating is limited to 2 Hours. * Indicates such products shall bear the UL or cul Certification Mark for jurisdictions employing the UL or cul Certification (such as Canada), respectively. Last Updated on Questions? Print this page Terms of Use Page Top 2016 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a nonmisleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " 2016 UL LLC". bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 1133&ccnshorttitle=Through penetration+firestop+systems 4/4

8 10/19/2016 XHEZ.F A 5043 Through penetration Firestop Systems System No. F A 5043 XHEZ.F A 5043 Through penetration Firestop Systems Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ Through penetration Firestop Systems XHEZ7 Through penetration Firestop Systems Certified for Canada See General Information for Through penetration Firestop Systems See General Information for Through penetration Firestop Systems Certified for Canada System No. F A 5043 September 16, 2016 ANSI/UL1479 (ASTM E814) CAN/ULC S115 F Ratings 2 or 3 Hr (See Items 1 and 2) F Ratings 2 or 3 Hr (See Items 1 and 2) T Ratings 1 1/4 or 1 1/2 Hr (See Item 2) FT Ratings 1 1/4 or 1 1/2 Hr (See Item 2) L Rating At Ambient Less Than 1 CFM/ft 2 FH Ratings 2 or 3 Hr (See Items 1 and 2) L Rating At 400 F Less Than 1 CFM/ft 2 FTH Ratings 1 1/4 or 1 1/2 Hr W Rating Class 1 (see Item 4) L Rating At Ambient Less Than 5.1 L/s/m 2 L Rating At 400 F Less Than 5.1 L/s/m 2 bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 5043&ccnshorttitle=Through penetration+firestop+systems 1/4

9 10/19/2016 XHEZ.F A 5043 Through penetration Firestop Systems Configuration A Configuration B bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 5043&ccnshorttitle=Through penetration+firestop+systems 2/4

10 10/19/2016 XHEZ.F A 5043 Through penetration Firestop Systems System tested with a pressure differential of 2.5 Pa between the exposed and the unexposed surfaces with the higher pressure on the exposed side. Configuration A 1. Floor Assembly Min 4 1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete. 1A. Alternate Floor Assembly (Not Shown) The fire rated unprotected concrete and steel deck floor assembly shall be constructed of the material and in the manner specified in the individual D900 Series designs in the UL Fire Resistance Directory and as summarized below: A. Concrete Min 2 1/2 in. (64 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete, as measured from the top plane of the steel floor units. B. Steel Floor and Form Units* Composite or non composite max 3 in. (76 mm) deep galv steel fluted units as specified in the individual Floor Ceiling Design. 2. Firestop Device* Sleeve Max 8 in. (203 mm) diam WD sleeve or Max 6 in. (152 mm) HFP Series cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. For HFP devices the optional accessories (not shown) includes a sleeve extension, deck adapter and/or water dam installed in accordance with installation instructions. The device shall be installed flush with top and bottom surfaces of floor. The devices are sized to accommodate the following nom pipe sizes: Nom Pipe Diam in. (mm) with (Item 4 below) Insulation Thickness will determine which device size to use. Firestop Devices for Concrete Slab Firestop Devices for Fluted Deck (Not Shown) 1/2 to 1 (13 to 25) HFP P1, HFP M1, HFP H2, HFP P1B, HFP M1B, HFP H2B 1 1/4 to 2 (32 to 51) HFP P2, HFP M2, HFP H3, HFP P2B, HFP M2B, HFP H3B 2 to 3 (51 to 76) HFP P3, HFP M3, HFP H4, HFP P3B, HFP M3B, HFP H4B 3 to 4 (76 to 102) HFP P4, HFP M4, HFP H5, HFP P4B, HFP M4B, HFP H5B HFP P6, HFP P6B, HFP M6, HFP M6B, HFP H7, HFP H7B add HFPCD1 add HFPCD2 add HFPCD3 add HFPCD4 add HFPCD6 HFP Series devices do not reqire the use of Packing material (Item 5) or Sealant (Item 6) when sized according to manufacturer's instructions. SECURUS INC, DBA HOLDRITE HFP Px, HFP Hx, HFP PxB, HFP HxB, HFP Mx and HFP MxB F Rating is limited to 2 hour when HFP H series devices are used in Config A & all other HFP series devices hav a 3 hour F Rating and a 1 1/4 T Rating. Configuration B Note: F rating is limited to 2 hours when configuration B is used. 1. Floor Assembly Min 4 1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete. 1A. Alternate Floor Assembly (Not Shown) The fire rated unprotected concrete and steel deck floor assembly shall be constructed of the material and in the manner specified in the individual D900 Series designs in the UL Fire Resistance Directory and as summarized below: A. Concrete Min 4 1/2 in. (64 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete, as measured from the top plane of the steel floor units. B. Steel Floor and Form Units* Composite or non composite max 3 in. (76 mm) deep galv steel fluted units as specified in the individual Floor Ceiling Design. 2. Firestop Device* Sleeve Max 8 in. (203 mm) diam cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. The device shall be installed flush with top and bottom surfaces of floor. The devices are sized to accommodate the nom pipe sizes: SECURUS INC, DBA HOLDRITE HydroFlame WD, CD Sleeve bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 5043&ccnshorttitle=Through penetration+firestop+systems 3/4

11 10/19/2016 XHEZ.F A 5043 Through penetration Firestop Systems When HydroFlame WD 0600 Sleeve is used, the nominal 1 by 0.3 in. (25 by 7.6 mm) void created by the stepped base within the sleeve shall be tightly packed with mineral wool batt insulation (Item 4) during firestop installation if concrete floor assembly is less than 7 in. (178 mm) thick. 3. Through Penetrant One metallic pipe or tubing to be centered within the firestop system. Pipe or tubing to be rigidly supported on both sides of floor assembly. The following types of pipe or tubing may be used: A. Steel Pipe Nom 4 in. (102 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Copper Tubing Nom 4 in. (102 mm) diam (or smaller) Type M (or heavier) copper tubing. C. Copper Pipe Nom 4 in. (102) diam (or smaller) Regular (or heavy) copper pipe. D. Iron Pipe Nom 4 in. (152 mm) diam (or smaller) cast or ductile iron pipe. 4. Pipe Covering* Max 1 1/2 in. (38 mm) thick hollow cylindrical heavy density mineral fiber units with an all service jacket. Longitudinal joints sealed with metal fasteners or factory applied self sealing lap tape. Transverse joints secured with metal fasteners or with butt tape supplied with the product. A min annular space of 1/2 in. (13 mm) is required within the firestop system. See Pipe and Equipment Covering Materials (BRGU) category in the Building Materials Directory for names of manufacturers. Any pipe covering meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index of 50 or less may be used. Note: L and W Rating only apply when pipe covering is 1/2 in. (13 mm) or less. 5. Packing Material Min 3 3/4 in. (95 mm) thickness of min 4 pcf (64 kg/m 3 ) mineral wool batt insulation firmly packed into opening as a permanent form so that the width of the wool is compressed at least 50 percent. Packing material to be recessed from top surface of floor as required to accommodate the required thickness of fill material. Packing material is optional for HFP Px, HFP PxB, HFP Mx, HFP MxB series devices (See Item 2). 6. Fill, Void or Cavity Material* Sealant Min 1/4 in. (6 mm) thickness of sealant applied within the annulus, flush with the top surface of floor. When pipe covering (Item 4) thickness is greater than 1 in. (25 mm), the min thickness of sealant applied within the annulus shall be 1/2 in. (13 mm). Sealant is optional for HFP Px, HFP PxB, HFP Mx, HFP MxB series devices (See Item 2). 3M COMPANY 3M FIRE PROTECTION PRODUCTS FB 1000NS, FB 1003SL, FB 3000 WT RECTORSEAL Metacaulk 835+ or Biotherm 100 or 200 * Indicates such products shall bear the UL or cul Certification Mark for jurisdictions employing the UL or cul Certification (such as Canada), respectively. Last Updated on Questions? Print this page Terms of Use Page Top 2016 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a nonmisleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " 2016 UL LLC". bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 5043&ccnshorttitle=Through penetration+firestop+systems 4/4

12 PRODUCT SPECIFICATION DRAWING Hydroflame Sleeves Accessory - CD Plates CD Plate See Dim "A" CD Plate See Dim "C" See Dim "B" (Corrugated Deck) Shown with Corrugated Metal Deck Application (All Sizes, 1", 2", 3", 4" & 6") The HOLDRITE Hydroflame "Corrugated Metal Deck Plates" transition cast-in-place firestop sleeving devices from use on a flat form deck into a sleeve for use on a corrugated metal form deck. Available for all Pro Series Sleeve sizes. Steel plate snaps onto the Base of the sleeve securely. (#8 screws can be be added for increased strength) Product Information: Material: 18GA, Galvanized CRS Patents Pending See Hydroflame Pro Series Installation Instructions, Best Practices documents and the lastest UL Fire Resistive Directory file (R25101) for details. THIS INFORMATION IS PROPRIETARY TO HOLDRITE AND IS SUBJECT TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION OR / FAX: / spec_hfp Series, CD, pg6 of 12_RevA

13 PRODUCT SPECIFICATION DRAWING Hydroflame Pro Series - Sleeve Extensions Sleeve Extension 5-5/16" (All Sizes) Extends Sleeve Height By Up To 4-3/4" The HOLDRITE Hydroflame Pro Series "Sleeve Extensions" (#HFPE1 - #HFPE6) are available to fit a wide variety of Sleeve combinations, from 1" thru 6" sizes. Each extension adds up to 4-3/4" of height in 1/4" increments. No coupling is needed! Height markings are shown on each part, in both U.S. and metric. Product Information: Material: Body: Polypropylene. Patented & Patents Pending. See Hydroflame Pro Series Installation Instructions, Best Practices documents and the lastest UL Fire Resistive Directory file (R25101) for details. THIS INFORMATION IS PROPRIETARY TO HOLDRITE AND IS SUBJECT TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION OR / FAX: / spec_hfp Series, Sleeve Extensions, pg7 of 12_RevA

14 PRODUCT SPECIFICATION DRAWING Hydroflame Pro Series - Water Dam Water Dam CD Plate (optional) The HOLDRITE Hydroflame Pro Series "Water Dam" attaches to the top of the Pro Series cast-in-place firestop sleeves and adds a 2" tall water dam barrier at the perimeter of the sleeve opening. Sizes are available to fit all Pro Series Sleeves, for all sizes of penetrants 1/2" thru 6" nominal size. See Riser Clamp load rating chart below. Thread sealant may be added to male threads prior to installation, if desired. UL-Listed accessory when used with HoldRite's Hydroflame Pro Series Sleeves. Product Information: Material: Body: PVC, Black. Patent Pending See Hydroflame Pro Series Installation Instructions, Best Practices documents and the lastest UL Fire Resistive Directory file (R25101) for details. THIS INFORMATION IS PROPRIETARY TO HOLDRITE AND IS SUBJECT TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION OR / FAX: / spec_hfp Series, Water Dam, pg3 of 12_RevA

15 PRODUCT SPECIFICATION DRAWING Hydroflame Pro Series - Water Module Water Module CD Plate (optional) The HOLDRITE Hydroflame Pro Series "Water Module" (#HFPWM1 - #HFPWM6) attaches to the top of the Pro Series Sleeves and provide a water, smoke and debris stop for 1/2" thru 6" piping. It is a UL Listed, W-Rated accessory that is cast into concrete or can be attached to Pro Series "Water Dam" fittings. Adds 1/2" to height of sleeve. Product Information: Material: Body: Polypropylene Seal: Thermal Plastic Rubber (TPR); Mold & Fungus resistant per ASTM G-21. Patented & Patents Pending See Hydroflame Pro Series Installation Instructions, Best Practices documents and the lastest UL Fire Resistive Directory file (R25101) for details. THIS INFORMATION IS PROPRIETARY TO HOLDRITE AND IS SUBJECT TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION OR / FAX: / spec_hfp Series, Water Module, pg2 of 12_RevA

16 PRODUCT SPECIFICATION DRAWING Hydroflame Pro Series - Hollow Sleeves See Dim *"C" (Telescoping) CD Plate (optional) Telescoping CD Plate (optional) See Dim "B" See Dim "A" * Note: Non-Telescoping Height range: 2-1/2" to 12". Height range: 2-1/2" to 7-3/4" ("-B" version). Both standard & "-B" style can be extended by adding sleeving extension. Sleeves have black Bases & black Locator Whiskers. The use of the Locator Whiskers is optional. * 7-3/4" Non-Telescoping Version ("-B") The HOLDRITE Hydroflame Pro Series "Hollow Sleeves" are UL Listed Firestop Sleeves, when installed per UL System Drawings (with backing material & fire caulking). Both telescoping (8" thru 12") and non-telescoping (7-3/4") are available. Can be cut as short as 4-1/2". For use with metallic pipes 1/2" thru 6" and for non-metallic pipes 1/2" thru 2". Optional Mid-Body Water Seal is available by ordering with a "-S" suffix on the model number. Safety Caps are OSHA compliant hole covers and include "Locator Whiskers". A wide variety of accessories can be added onto these sleeves. UL F-Rating can achieve 2 or 3 hours. UL T, L & W Ratings can also be achieved when installed per UL Systems. Product Information: Material: Main Sleeve Body, Base & Safety Cap: Polypropylene. Locator Whiskers: Nylon. Patended & Patents Pending. See Hydroflame Pro Series Installation Instructions, Best Practices documents and the lastest UL Fire Resistive Directory file (R25101) for details. THIS INFORMATION IS PROPRIETARY TO HOLDRITE AND IS SUBJECT TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION OR / FAX: / spec_hfp Series, Hollow Sleves, pg12 of 12_RevB

17 10/27/2016 XHEZ.F A 1122 Through penetration Firestop Systems System No. F A 1122 XHEZ.F A 1122 Through penetration Firestop Systems Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ Through penetration Firestop Systems XHEZ7 Through penetration Firestop Systems Certified for Canada See General Information for Through penetration Firestop Systems See General Information for Through penetration Firestop Systems Certified for Canada System No. F A 1122 September 12, 2016 ANSI/UL1479 (ASTM E814) CAN/ULC S115 F Rating 2 Hr T Rating 0 Hr L Rating At Ambient Less Than 1 CFM/sq ft L Rating At 400 F 2 CFM/sq ft F Rating 2 Hr FT Rating 0 Hr FH Rating 2 Hr FTH Rating 0 Hr W Rating Class 1 L Rating At Ambient Less Than 5.1 L/s/m 3 L Rating At 400 F 10.2 L/s/m 3 bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 1122&ccnshorttitle=Through penetration+firestop+systems 1/4

18 10/27/2016 XHEZ.F A 1122 Through penetration Firestop Systems Configuration A Configuration B bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 1122&ccnshorttitle=Through penetration+firestop+systems 2/4

19 10/27/2016 XHEZ.F A 1122 Through penetration Firestop Systems 1. Floor Assembly Min 4 1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete measured above the base of the device. 1A. Alternate Floor Assembly (Optional, Not Shown) The fire rated unprotected concrete and steel floor assembly shall be constructed of the materials and in the manner specified in the individual D900 Series designs in the UL Fire Resistance Directory and as summarized below: A. Concrete Min 4 1/2 in. (114 mm) thick reinforced lightweight or normal weight pcf ( kg/m 3 ) concrete, measured above the base of the device. B. Steel Floor and Form Units* Composite or non composite max 3 in. (76 mm) deep galv steel fluted units as specified in the individual Floor Ceiling Design. Configuration A 2. Firestop Device* Cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. The device shall be installed flush with top and bottom surfaces of floor. Optional accessories (not shown) includes sleeve extension, water module, deck adapter, mid body seal and/or aerator adapter installed in accordance with installation instructions. The devices are sized to accommodate the following nom pipe sizes: Nom Pipe Diam in. (mm) Devices for Concrete Slab Devices for Fluted Deck (Not Shown) 1/4 to 1 1/4 (6 to 32) HFP H2, HFP H2B add HFPCD1 1 to 2 (25 to 51) HFP H3, HFP H3B add HFPCD2 1 1/4 to 3 (32 to 76) HFP H4, HFP H4B add HFPCD3 2 1/2 to 4 (64 to 102) HFP H5, HFP H5B add HFPCD4 4 to 6 (102 to 152) HFP H7, HFP H7B add HFPCD6 SECURUS INC, DBA HOLDRITE HydroFlame, HFP Hx, HFP HxB 3. Through Penetrant One metallic pipe, conduit or tubing installed concentrically within the firestop system. The annular space shall be min 1/2 in. (13 mm) to max 2 3/8 in. (60 mm). Pipe, conduit or tubing to be rigidly supported on both sides of floor assembly. The following types of pipe, conduit or tubing may be used: A. Steel Pipe Nom 6 in. (152 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Conduit Nom 6 in. (152 mm) diam (or smaller) steel electrical metallic tubing (EMT) or steel conduit. C. Copper Tubing Nom 6 in. (152 mm) diam (or smaller) Type M (or heavier) copper tubing. D. Iron Pipe Nom 6 in. (152 mm) diam (or smaller) cast or ductile iron pipe. 4. Packing Material Min 3 3/4 in. (95 mm) thickness of min 4 pcf (64 kg/m 3 ) mineral wool batt insulation firmly packed into opening as a permanent form so that the width of the wool is compressed at least 50 percent. Packing material to be recessed from top surface of floor as required to accommodate the required thickness of fill material. 5. Fill, Void or Cavity Material* Sealant Min 1/4 in. (6 mm) thickness of sealant applied within the annulus, flush with the top surface of floor to attain W Rating. 3M COMPANY 3M FIRE PROTECTION PRODUCTS FB 1000 NS, FB 1003SL or FB 3000 WT RECTORSEAL Metacaulk 835+ or Biotherm 100 or Pipe Tee Fitting System (Optional, Not Shown) For use with Iron Pipe (Item 3D) only. One nom 6 in. (152 mm) diam (or smaller) PVC TESTRITE TEE Fitting (matched to penetrant diameter). The PVC TESTRITE TEE Fitting is secured to metallic penetrant (Item 3D) with compression type pipe coupling elastomeric gasket with stainless steel jacket and stainless steel band clamps for use in vented (drain, waste or vent) iron pipe systems. Installed (Item 3D) penetrant shall extend a minimum of 6 in. (152 mm) above the surface of the floor and minimum 12 in. (302 mm) below the bottom surface of the floor above assembly. Configuration B 2. Firestop Device* Max 8 in. (203 mm) diam cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. The device shall be installed flush with top and bottom surfaces of floor. Optional accessory (not shown) aerator adapter installed in accordance with the installation instructions. SECURUS INC, DBA HOLDRITE HydroFlame WD, CD Sleeve bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 1122&ccnshorttitle=Through penetration+firestop+systems 3/4

20 10/27/2016 XHEZ.F A 1122 Through penetration Firestop Systems When HydroFlame WD 0600 Sleeve is used, the nominal 1 by 0.3 in. (25 by 7.6 mm) void created by the stepped base within the sleeve shall be tightly packed with mineral wool batt insulation (Item 4) during firestop installation if concrete floor assembly is less than 7 in. (178 mm) thick. 3. Through Penetrant One metallic pipe, conduit or tubing installed concentrically within the firestop system. The annular space shall be min 1/2 in. (13 mm) to max 2 3/8 in. (60 mm). Pipe, conduit or tubing to be rigidly supported on both sides of floor assembly. The following types of pipe, conduit or tubing may be used: A. Steel Pipe Nom 4 in. (102 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Conduit Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing (EMT) or steel conduit. C. Copper Tubing Nom 4 in. (102 mm) diam (or smaller) Type M (or heavier) copper tubing. D. Iron Pipe Nom 6 in. (152 mm) diam (or smaller) cast or ductile iron pipe. 4. Packing Material Min 3 3/4 in. (95 mm) thickness of min 4 pcf (64 kg/m 3 ) mineral wool batt insulation firmly packed into opening as a permanent form so that the width of the wool is compressed at least 50 percent. Packing material to be recessed from top surface of floor as required to accommodate the required thickness of fill material. 5. Fill, Void or Cavity Material* Sealant Min 1/4 in. (6 mm) thickness of sealant applied within the annulus, flush with the top surface of floor. Sealant must lap onto top surface of concrete floor around entire perimeter of firestop device to attain W Rating. 3M COMPANY 3M FIRE PROTECTION PRODUCTS FB 1000 NS, FB 1003SL or FB 3000 WT RECTORSEAL Metacaulk 835+ or Biotherm 100 or Pipe Tee Fitting System (Optional, Not Shown) For use with Iron Pipe (Item 3D) only. One nom 6 in. (152 mm) diam (or smaller) PVC TESTRITE TEE Fitting (matched to penetrant diameter). The PVC TESTRITE TEE Fitting is secured to metallic penetrant (Item 3D) with compression type pipe coupling elastomeric gasket with stainless steel jacket and stainless steel band clamps for use in vented (drain, waste or vent) iron pipe systems. Installed (Item 3D) penetrant shall extend a minimum of 6 in. (152 mm) above the surface of the floor and minimum 12 in. (302 mm) below the bottom surface of the floor above assembly. * Indicates such products shall bear the UL or cul Certification Mark for jurisdictions employing the UL or cul Certification (such as Canada), respectively. Last Updated on Questions? Print this page Terms of Use Page Top 2016 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a nonmisleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " 2016 UL LLC". bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 1122&ccnshorttitle=Through penetration+firestop+systems 4/4

21 10/19/2016 XHEZ.F A 5043 Through penetration Firestop Systems System No. F A 5043 XHEZ.F A 5043 Through penetration Firestop Systems Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ Through penetration Firestop Systems XHEZ7 Through penetration Firestop Systems Certified for Canada See General Information for Through penetration Firestop Systems See General Information for Through penetration Firestop Systems Certified for Canada System No. F A 5043 September 16, 2016 ANSI/UL1479 (ASTM E814) CAN/ULC S115 F Ratings 2 or 3 Hr (See Items 1 and 2) F Ratings 2 or 3 Hr (See Items 1 and 2) T Ratings 1 1/4 or 1 1/2 Hr (See Item 2) FT Ratings 1 1/4 or 1 1/2 Hr (See Item 2) L Rating At Ambient Less Than 1 CFM/ft 2 FH Ratings 2 or 3 Hr (See Items 1 and 2) L Rating At 400 F Less Than 1 CFM/ft 2 FTH Ratings 1 1/4 or 1 1/2 Hr W Rating Class 1 (see Item 4) L Rating At Ambient Less Than 5.1 L/s/m 2 L Rating At 400 F Less Than 5.1 L/s/m 2 bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 5043&ccnshorttitle=Through penetration+firestop+systems 1/4

22 10/19/2016 XHEZ.F A 5043 Through penetration Firestop Systems Configuration A Configuration B bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 5043&ccnshorttitle=Through penetration+firestop+systems 2/4

23 10/19/2016 XHEZ.F A 5043 Through penetration Firestop Systems System tested with a pressure differential of 2.5 Pa between the exposed and the unexposed surfaces with the higher pressure on the exposed side. Configuration A 1. Floor Assembly Min 4 1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete. 1A. Alternate Floor Assembly (Not Shown) The fire rated unprotected concrete and steel deck floor assembly shall be constructed of the material and in the manner specified in the individual D900 Series designs in the UL Fire Resistance Directory and as summarized below: A. Concrete Min 2 1/2 in. (64 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete, as measured from the top plane of the steel floor units. B. Steel Floor and Form Units* Composite or non composite max 3 in. (76 mm) deep galv steel fluted units as specified in the individual Floor Ceiling Design. 2. Firestop Device* Sleeve Max 8 in. (203 mm) diam WD sleeve or Max 6 in. (152 mm) HFP Series cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. For HFP devices the optional accessories (not shown) includes a sleeve extension, deck adapter and/or water dam installed in accordance with installation instructions. The device shall be installed flush with top and bottom surfaces of floor. The devices are sized to accommodate the following nom pipe sizes: Nom Pipe Diam in. (mm) with (Item 4 below) Insulation Thickness will determine which device size to use. Firestop Devices for Concrete Slab Firestop Devices for Fluted Deck (Not Shown) 1/2 to 1 (13 to 25) HFP P1, HFP M1, HFP H2, HFP P1B, HFP M1B, HFP H2B 1 1/4 to 2 (32 to 51) HFP P2, HFP M2, HFP H3, HFP P2B, HFP M2B, HFP H3B 2 to 3 (51 to 76) HFP P3, HFP M3, HFP H4, HFP P3B, HFP M3B, HFP H4B 3 to 4 (76 to 102) HFP P4, HFP M4, HFP H5, HFP P4B, HFP M4B, HFP H5B HFP P6, HFP P6B, HFP M6, HFP M6B, HFP H7, HFP H7B add HFPCD1 add HFPCD2 add HFPCD3 add HFPCD4 add HFPCD6 HFP Series devices do not reqire the use of Packing material (Item 5) or Sealant (Item 6) when sized according to manufacturer's instructions. SECURUS INC, DBA HOLDRITE HFP Px, HFP Hx, HFP PxB, HFP HxB, HFP Mx and HFP MxB F Rating is limited to 2 hour when HFP H series devices are used in Config A & all other HFP series devices hav a 3 hour F Rating and a 1 1/4 T Rating. Configuration B Note: F rating is limited to 2 hours when configuration B is used. 1. Floor Assembly Min 4 1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete. 1A. Alternate Floor Assembly (Not Shown) The fire rated unprotected concrete and steel deck floor assembly shall be constructed of the material and in the manner specified in the individual D900 Series designs in the UL Fire Resistance Directory and as summarized below: A. Concrete Min 4 1/2 in. (64 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete, as measured from the top plane of the steel floor units. B. Steel Floor and Form Units* Composite or non composite max 3 in. (76 mm) deep galv steel fluted units as specified in the individual Floor Ceiling Design. 2. Firestop Device* Sleeve Max 8 in. (203 mm) diam cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. The device shall be installed flush with top and bottom surfaces of floor. The devices are sized to accommodate the nom pipe sizes: SECURUS INC, DBA HOLDRITE HydroFlame WD, CD Sleeve bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 5043&ccnshorttitle=Through penetration+firestop+systems 3/4

24 10/19/2016 XHEZ.F A 5043 Through penetration Firestop Systems When HydroFlame WD 0600 Sleeve is used, the nominal 1 by 0.3 in. (25 by 7.6 mm) void created by the stepped base within the sleeve shall be tightly packed with mineral wool batt insulation (Item 4) during firestop installation if concrete floor assembly is less than 7 in. (178 mm) thick. 3. Through Penetrant One metallic pipe or tubing to be centered within the firestop system. Pipe or tubing to be rigidly supported on both sides of floor assembly. The following types of pipe or tubing may be used: A. Steel Pipe Nom 4 in. (102 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Copper Tubing Nom 4 in. (102 mm) diam (or smaller) Type M (or heavier) copper tubing. C. Copper Pipe Nom 4 in. (102) diam (or smaller) Regular (or heavy) copper pipe. D. Iron Pipe Nom 4 in. (152 mm) diam (or smaller) cast or ductile iron pipe. 4. Pipe Covering* Max 1 1/2 in. (38 mm) thick hollow cylindrical heavy density mineral fiber units with an all service jacket. Longitudinal joints sealed with metal fasteners or factory applied self sealing lap tape. Transverse joints secured with metal fasteners or with butt tape supplied with the product. A min annular space of 1/2 in. (13 mm) is required within the firestop system. See Pipe and Equipment Covering Materials (BRGU) category in the Building Materials Directory for names of manufacturers. Any pipe covering meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index of 50 or less may be used. Note: L and W Rating only apply when pipe covering is 1/2 in. (13 mm) or less. 5. Packing Material Min 3 3/4 in. (95 mm) thickness of min 4 pcf (64 kg/m 3 ) mineral wool batt insulation firmly packed into opening as a permanent form so that the width of the wool is compressed at least 50 percent. Packing material to be recessed from top surface of floor as required to accommodate the required thickness of fill material. Packing material is optional for HFP Px, HFP PxB, HFP Mx, HFP MxB series devices (See Item 2). 6. Fill, Void or Cavity Material* Sealant Min 1/4 in. (6 mm) thickness of sealant applied within the annulus, flush with the top surface of floor. When pipe covering (Item 4) thickness is greater than 1 in. (25 mm), the min thickness of sealant applied within the annulus shall be 1/2 in. (13 mm). Sealant is optional for HFP Px, HFP PxB, HFP Mx, HFP MxB series devices (See Item 2). 3M COMPANY 3M FIRE PROTECTION PRODUCTS FB 1000NS, FB 1003SL, FB 3000 WT RECTORSEAL Metacaulk 835+ or Biotherm 100 or 200 * Indicates such products shall bear the UL or cul Certification Mark for jurisdictions employing the UL or cul Certification (such as Canada), respectively. Last Updated on Questions? Print this page Terms of Use Page Top 2016 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a nonmisleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " 2016 UL LLC". bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 5043&ccnshorttitle=Through penetration+firestop+systems 4/4

25 Cap & Locator Whiskers PRODUCT SPECIFICATION DRAWING Hydroflame Pro Series Sleeves * See Dim "C" (Telescoping) CD Plate (optional) Safety Cap & Locator Whiskers Included (Shown with optional CD Plate) (OSHA Compliant Hole Cover) * Note: Height range: 2-1/2" to 12". Height range: 2-1/2" to 7-3/4" ("-B" version). Both standard & "-B" style can be extended by adding sleeving extension. Sleeves with black Bases & black Locator Whiskers are for use with metallic penetrants. Sleeve with red Bases & red Locator Whiskers are for use with either metallic or non-metallic (plastic) penetrants. The use of the Locator Whiskers is optional. See Dim "B" See Dim "A" * 7-3/4" Non-Telescoping Version ("-B") The HOLDRITE Hydroflame Pro Series Sleeving System consists of UL & cul listed assemblies that provide sleeving & firestop solutions for cast-in-place concrete floors. These sleeve products provide solutions for both metallic & non-metallic pipes, line-sets, cables, conduits, floor drains, tub drains, shower drains and toilet drains. For slabs 2 ½" and thicker and for pipes, conduits & cables ½" - 6" nominal; 2 & 3 hour UL Fire Ratings and T, L & W- ratings available. 50 Pa ratings available. See UL Fire Resistive Directory (R25101) for further details. Sleeves are easly adapted for use on Corrugated Metal Decking with the use of HoldRite's CD Plates. 16 models include: #HFP-P/M1 (B), #HFP-P/M2 (B), #HFP-P/M3 (B), #HFP-P/M4 (B) and #HFP-P/M6 (B). Product Information: Material: Main Sleeve Body & Safety Cap: Polypropylene Mid-Body Seal: Thermal Plastic Rubber (TPR); Mold & Fungus resistant per ASTM G-21. Locator Whiskers: Nylon Fire Ring: 24GA CRS Firestop Material: UL Listed Intumescent Composite Patented & Patents Pending See Hydroflame Pro Series Installation Instructions, Best Practices documents and the lastest UL Fire Resistive Directory file (R25101) for details. THIS INFORMATION IS PROPRIETARY TO HOLDRITE AND IS SUBJECT TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION OR / FAX: / spec_hfp Series, pg1 of 12_RevA

26 10/19/2016 XHEZ.F A 0026 Through penetration Firestop Systems System No. F A 0026 XHEZ.F A 0026 Through penetration Firestop Systems Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ Through penetration Firestop Systems XHEZ7 Through penetration Firestop Systems Certified for Canada See General Information for Through penetration Firestop Systems See General Information for Through penetration Firestop Systems Certified for Canada System No. F A 0026 September 12, 2016 ANSI/UL1479 (ASTM E814) CAN/ULC S115 F Rating 2 Hr T Rating 2 Hr L Rating At Ambient Less Than 1 CFM/sq ft L Rating At 400 F 2 CFM/sq ft F Rating 2 Hr FT Rating 2 Hr FH Rating 2 Hr FTH Rating 2 Hr W Rating Class 1 L Rating At Ambient Less Than 5.1 L/s/m 3 L Rating At 400 F 10.2 L/s/m 3 bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 0026&ccnshorttitle=Through penetration+firestop+systems 1/4

27 10/19/2016 XHEZ.F A 0026 Through penetration Firestop Systems Configuration A Configuration B System tested with a pressure differential of 2.5 Pa between the exposed and the unexposed surfaces with the higher pressure on the exposed side. 1. Floor Assembly Min 4 1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete. bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 0026&ccnshorttitle=Through penetration+firestop+systems 2/4

28 10/19/2016 XHEZ.F A 0026 Through penetration Firestop Systems 1A. Alternate Floor Assembly (Not Shown) The fire rated unprotected concrete and steel deck floor assembly shall be constructed of the material and in the manner specified in the individual D900 Series designs in the UL Fire Resistance Directory and as summarized below: A. Concrete Min 4 1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete, as measured from the top plane of the steel floor units. B. Steel Floor and Form Units* Composite or non composite max 3 in. (76 mm) deep galv steel fluted units as specified in the individual Floor Ceiling Design. 2. Firestop Device* Max 6 in. (152 mm) cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. The device shall be installed flush with top and bottom surfaces of floor. For HFP devices the optional accessory (not shown) includes a sleeve extension and / or deck adapter installed in accordance with installation instructions. The devices are sized to accommodate the following nom pipe sizes: Nom Pipe Diam in. (mm) Conf A Firestop Devices for Concrete Slab Conf A Firestop Devices for Fluted Deck (Not Shown) Conf B Firestop Devices for Concrete Slab Conf B Firestop Devices for Fluted Deck (Not Shown) 1/2 to 1 (13 to 25) HFP H Size Below 1/4 to 1 1/4 (6 to 32) HFP M1, HFP P1, HFP H2, HFP P1B, HFP M1B, HFP H2B add HFPCD1 WD sleeve CD sleeve 1 1/4 to 2 (32 to 51) HFP H Size Below 1 to 2 (25 to 51) HFP P2, HFP M2, HFP H3, HFP P2B, HFP M2B, HFP H3B add HFPCD2 WD sleeve CD sleeve 2 to 3 (51 to 76) HFP H Size Below 1 1/4 to 3 (32 to 76) HFP P3, HFP M3, HFP H4, HFP P3B, HFP M3B, HFP H4B add HFPCD3 WD sleeve CD sleeve 3 to 4 (76 to 102) HFP H Size Below 2 1/2 to 4 (64 to 102) HFP P4, HFP M4, HFP H5, HFP P4B, HFP M4B, HFP H5B add HFPCD4 WD sleeve CD sleeve 5 to 6 (127 to 152) HFP H Size Below 4 to 6 (102 to 152) HFP P6, HFP M6, HFP H7, HFP P6B, HFP M6B, HFP H7B add HFPCD6 WD sleeve CD sleeve SECURUS INC, DBA HOLDRITE (Configuration A) HFP Mx, HFP Px, HFP Hx, HFP PxB, HFP MxB, HFP HxB, (Configuration B) HydroFlame WD Sleeve, CD Sleeve When HydroFlame WD 0600 Sleeve is used, the nominal 1 by 0.3 in. (25 by 7.6 mm) void created by the stepped base within the sleeve shall be tightly packed with mineral wool batt insulation (Item 4) during firestop installation if concrete floor assembly is less than 7 in. (178 mm) thick. 3. Packing Material Min 3 3/4 in. (95 mm) thickness of min 4 pcf (64 kg/m 3 ) mineral wool batt insulation firmly packed into firestop device as a permanent form so that the width of the wool is compressed at least 50 percent. Packing material to be recessed from top surface of floor as required to accommodate the required thickness of fill material. 4. Fill, Void or Cavity Material* Sealant Min 1/4 in. (6 mm) thickness of sealant applied within the annulus, flush with the top surface of floor. Conf B, Sealant must lap onto top surface of concrete floor around entire perimeter of firestop device to attain W Rating. 3M COMPANY 3M FIRE PROTECTION PRODUCTS FB 1000 NS or FB 1003SL RECTORSEAL Metacaulk 835+, Biotherm 100 or bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 0026&ccnshorttitle=Through penetration+firestop+systems 3/4

29 PRODUCT SPECIFICATION DRAWING Hydroflame Sleeves Accessory - CD Plates CD Plate See Dim "A" CD Plate See Dim "C" See Dim "B" (Corrugated Deck) Shown with Corrugated Metal Deck Application (All Sizes, 1", 2", 3", 4" & 6") The HOLDRITE Hydroflame "Corrugated Metal Deck Plates" transition cast-in-place firestop sleeving devices from use on a flat form deck into a sleeve for use on a corrugated metal form deck. Available for all Pro Series Sleeve sizes. Steel plate snaps onto the Base of the sleeve securely. (#8 screws can be be added for increased strength) Product Information: Material: 18GA, Galvanized CRS Patents Pending See Hydroflame Pro Series Installation Instructions, Best Practices documents and the lastest UL Fire Resistive Directory file (R25101) for details. THIS INFORMATION IS PROPRIETARY TO HOLDRITE AND IS SUBJECT TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION OR / FAX: / spec_hfp Series, CD, pg6 of 12_RevA

30 PRODUCT SPECIFICATION DRAWING Hydroflame Pro Series - Hollow Sleeves See Dim *"C" (Telescoping) CD Plate (optional) Telescoping CD Plate (optional) See Dim "B" See Dim "A" * Note: Non-Telescoping Height range: 2-1/2" to 12". Height range: 2-1/2" to 7-3/4" ("-B" version). Both standard & "-B" style can be extended by adding sleeving extension. Sleeves have black Bases & black Locator Whiskers. The use of the Locator Whiskers is optional. * 7-3/4" Non-Telescoping Version ("-B") The HOLDRITE Hydroflame Pro Series "Hollow Sleeves" are UL Listed Firestop Sleeves, when installed per UL System Drawings (with backing material & fire caulking). Both telescoping (8" thru 12") and non-telescoping (7-3/4") are available. Can be cut as short as 4-1/2". For use with metallic pipes 1/2" thru 6" and for non-metallic pipes 1/2" thru 2". Optional Mid-Body Water Seal is available by ordering with a "-S" suffix on the model number. Safety Caps are OSHA compliant hole covers and include "Locator Whiskers". A wide variety of accessories can be added onto these sleeves. UL F-Rating can achieve 2 or 3 hours. UL T, L & W Ratings can also be achieved when installed per UL Systems. Product Information: Material: Main Sleeve Body, Base & Safety Cap: Polypropylene. Locator Whiskers: Nylon. Patended & Patents Pending. See Hydroflame Pro Series Installation Instructions, Best Practices documents and the lastest UL Fire Resistive Directory file (R25101) for details. THIS INFORMATION IS PROPRIETARY TO HOLDRITE AND IS SUBJECT TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION OR / FAX: / spec_hfp Series, Hollow Sleves, pg12 of 12_RevB

31 10/19/2016 XHEZ.F A 0026 Through penetration Firestop Systems System No. F A 0026 XHEZ.F A 0026 Through penetration Firestop Systems Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ Through penetration Firestop Systems XHEZ7 Through penetration Firestop Systems Certified for Canada See General Information for Through penetration Firestop Systems See General Information for Through penetration Firestop Systems Certified for Canada System No. F A 0026 September 12, 2016 ANSI/UL1479 (ASTM E814) CAN/ULC S115 F Rating 2 Hr T Rating 2 Hr L Rating At Ambient Less Than 1 CFM/sq ft L Rating At 400 F 2 CFM/sq ft F Rating 2 Hr FT Rating 2 Hr FH Rating 2 Hr FTH Rating 2 Hr W Rating Class 1 L Rating At Ambient Less Than 5.1 L/s/m 3 L Rating At 400 F 10.2 L/s/m 3 bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 0026&ccnshorttitle=Through penetration+firestop+systems 1/4

32 10/19/2016 XHEZ.F A 0026 Through penetration Firestop Systems Configuration A Configuration B System tested with a pressure differential of 2.5 Pa between the exposed and the unexposed surfaces with the higher pressure on the exposed side. 1. Floor Assembly Min 4 1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete. bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 0026&ccnshorttitle=Through penetration+firestop+systems 2/4

33 10/19/2016 XHEZ.F A 0026 Through penetration Firestop Systems 1A. Alternate Floor Assembly (Not Shown) The fire rated unprotected concrete and steel deck floor assembly shall be constructed of the material and in the manner specified in the individual D900 Series designs in the UL Fire Resistance Directory and as summarized below: A. Concrete Min 4 1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete, as measured from the top plane of the steel floor units. B. Steel Floor and Form Units* Composite or non composite max 3 in. (76 mm) deep galv steel fluted units as specified in the individual Floor Ceiling Design. 2. Firestop Device* Max 6 in. (152 mm) cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. The device shall be installed flush with top and bottom surfaces of floor. For HFP devices the optional accessory (not shown) includes a sleeve extension and / or deck adapter installed in accordance with installation instructions. The devices are sized to accommodate the following nom pipe sizes: Nom Pipe Diam in. (mm) Conf A Firestop Devices for Concrete Slab Conf A Firestop Devices for Fluted Deck (Not Shown) Conf B Firestop Devices for Concrete Slab Conf B Firestop Devices for Fluted Deck (Not Shown) 1/2 to 1 (13 to 25) HFP H Size Below 1/4 to 1 1/4 (6 to 32) HFP M1, HFP P1, HFP H2, HFP P1B, HFP M1B, HFP H2B add HFPCD1 WD sleeve CD sleeve 1 1/4 to 2 (32 to 51) HFP H Size Below 1 to 2 (25 to 51) HFP P2, HFP M2, HFP H3, HFP P2B, HFP M2B, HFP H3B add HFPCD2 WD sleeve CD sleeve 2 to 3 (51 to 76) HFP H Size Below 1 1/4 to 3 (32 to 76) HFP P3, HFP M3, HFP H4, HFP P3B, HFP M3B, HFP H4B add HFPCD3 WD sleeve CD sleeve 3 to 4 (76 to 102) HFP H Size Below 2 1/2 to 4 (64 to 102) HFP P4, HFP M4, HFP H5, HFP P4B, HFP M4B, HFP H5B add HFPCD4 WD sleeve CD sleeve 5 to 6 (127 to 152) HFP H Size Below 4 to 6 (102 to 152) HFP P6, HFP M6, HFP H7, HFP P6B, HFP M6B, HFP H7B add HFPCD6 WD sleeve CD sleeve SECURUS INC, DBA HOLDRITE (Configuration A) HFP Mx, HFP Px, HFP Hx, HFP PxB, HFP MxB, HFP HxB, (Configuration B) HydroFlame WD Sleeve, CD Sleeve When HydroFlame WD 0600 Sleeve is used, the nominal 1 by 0.3 in. (25 by 7.6 mm) void created by the stepped base within the sleeve shall be tightly packed with mineral wool batt insulation (Item 4) during firestop installation if concrete floor assembly is less than 7 in. (178 mm) thick. 3. Packing Material Min 3 3/4 in. (95 mm) thickness of min 4 pcf (64 kg/m 3 ) mineral wool batt insulation firmly packed into firestop device as a permanent form so that the width of the wool is compressed at least 50 percent. Packing material to be recessed from top surface of floor as required to accommodate the required thickness of fill material. 4. Fill, Void or Cavity Material* Sealant Min 1/4 in. (6 mm) thickness of sealant applied within the annulus, flush with the top surface of floor. Conf B, Sealant must lap onto top surface of concrete floor around entire perimeter of firestop device to attain W Rating. 3M COMPANY 3M FIRE PROTECTION PRODUCTS FB 1000 NS or FB 1003SL RECTORSEAL Metacaulk 835+, Biotherm 100 or bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 0026&ccnshorttitle=Through penetration+firestop+systems 3/4

34 PRODUCT SPECIFICATION DRAWING Hydroflame Pro Series - Cable & Line-Set Sleeves Cable & Line-Set Sleeve CD Plate (optional) The HOLDRITE Hydroflame Pro Series "Cable & Line-Set Sleeves" are UL Listed Firestop Devices that provide 3- hour fire ratings (as well as "T", "L" & "W" ratings, when installed per UL system drawings). Telescoping and nontelescoping versions are available. The Sleeves are approved to accept up to 45% cable fill, refrigeration line-sets and multiple small pipes. Six sleeve sizes/varieties available. Optional "CD Plate" can be used for metal deck forms. Models include #HFP-CSM2, #HFP-CSM3, #HFP-CSM2B, #HFP-CSM3B, #HFP-LSP3 and #HFP-LSP3B. Product Information: Material: Main Sleeve Body, Base & Safety Cap: Polypropylene. Mid-Body Seal: Thermal Plastic Rubber (TPR); Mold & Fungus resistant per ASTM G-21. Locator Whiskers: Nylon. Fire Ring: 24GA CRS. Firestop Material: UL Listed Intumescent Composite. Patended & Patents Pending. See Hydroflame Pro Series Installation Instructions, Best Practices documents and the lastest UL Fire Resistive Directory file (R25101) for details. THIS INFORMATION IS PROPRIETARY TO HOLDRITE AND IS SUBJECT TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION OR / FAX: / spec_hfp Series, Cable & Line-Set Sleeves, pg10 of 12_RevA

35 10/19/2016 XHEZ.F A 3052 Through penetration Firestop Systems System No. F A 3052 XHEZ.F A 3052 Through penetration Firestop Systems Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ Through penetration Firestop Systems XHEZ7 Through penetration Firestop Systems Certified for Canada See General Information for Through penetration Firestop Systems See General Information for Through penetration Firestop Systems Certified for Canada System No. F A 3052 September 12, 2016 ANSI/UL1479 (ASTM E814) CAN/ULC S115 F Rating 3 Hr T Rating 1/4 Hr L Rating At Ambient Less Than 1 CFM/ft 2 L Rating At 400 F Less Than 1 CFM/ft 2 F Rating 3 Hr FT Rating 1/4 Hr FH Rating 3 Hr FTH Rating 1/4 Hr W Rating Class 1 L Rating At Ambient Less Than 5.1 L/s/m 2 L Rating At 400 F Less Than 5.1 L/s/m 2 bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 3052&ccnshorttitle=Through penetration+firestop+systems 1/4

36 10/19/2016 XHEZ.F A 3052 Through penetration Firestop Systems Configuration A Configuration B bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 3052&ccnshorttitle=Through penetration+firestop+systems 2/4

37 10/19/2016 XHEZ.F A 3052 Through penetration Firestop Systems System tested with a pressure differential of 2.5 Pa between the exposed and the unexposed surfaces with the higher pressure on the exposed side. 1. Floor Assembly Min 4 1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete. 1A. Alternate Floor Assembly (Not Shown) The fire rated unprotected concrete and steel deck floor assembly shall be constructed of the material and in the manner specified in the individual D900 Series designs in the UL Fire Resistance Directory and as summarized below: A. Concrete Min 4 1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete, as measured from the top plane of the steel floor units. B. Steel Floor and Form Units* Composite or non composite max 3 in. (76 mm) deep galv steel fluted units as specified in the individual Floor Ceiling Design. 2. Firestop Device* Cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. For HFP devices the optional accessories (not shown) includes sleeve extension and/ or deck adapter, installed in accordance with installation instructions. The device shall be installed flush with top and bottom surfaces of floor. The devices are sized to accommodate the following nom pipe sizes: Nom Pipe Diam in. (mm) Conf A Firestop Devices for Concrete Slab Conf A Firestop Devices for Fluted Deck (Not Shown) Conf B Firestop Devices for Concrete Slab Conf B Firestop Devices for Fluted Deck (Not Shown) 1 1/4 to 2 (32 to 51) 2 to 3 (51 to 76) HFP CSM2, HFP CSM2B, HFP P2, HFP P2B, HFP M2, HFP M2B HFP CSM3, HFP CSM3B, HFP P3, HFP P3B, HFP M3, HFP M3B add HFPCD2 PS CS 0200 CD CS 0200 add HFPCD3 PS CS 0300 CD CS 0300 SECURUS INC, DBA HOLDRITE (Configuration A) HFP CSMx, HFP CSMxB, HFP Px, HFP PxB, HFP Mx, HFP MxB; (Configuration B) HydroFlame PS CS, CD CS 3. Cables Aggregate cross sectional area of cables in opening to be max 45 percent of the cross sectional area of the nom 2 in. (51 mm) or 3 in. (76 mm) diam firestop device throat. Min separation between cables and between cables and periphery of firestop device throat is 1/8 in. (3.2 mm). Cables to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of copper conductor cables may be used: A. Max 1/C 500 kcmil cable with crosslinked polyethylene (XLPE) jacket. B. Max 8/C No. 12 AWG or max 12/C No. 14 AWG cable with XLPE insulation and jacket. C. Max 100 pair No. 24 AWG cable with PVC insulation and jacket. 4. Packing Material Min 2 in. (51 mm) depth of min 4 pcf (64 kg/m 3 ) mineral wool batt insulation firmly packed into top of firestop device as a permanent form. Packing material to be recessed from top surface of floor as required to accommodate the required thickness of fill material. 5. Fill, Void or Cavity Material* Sealant Min 1/4 in. (6 mm) thickness of sealant applied within the annulus, flush with the top surface of floor. Sealant to be forced into interstices of cable group to max extent possible. Conf B (Only) Sealant to lap min 1/2 in. (13 mm) onto top surface of concrete around perimeter of firestop device. 3M COMPANY 3M FIRE PROTECTION PRODUCTS FB 1000 NS, FB 3000 WT or FB 1003 SL RECTORSEAL Metacaulk 835+ or Biotherm 100 or 200 * Indicates such products shall bear the UL or cul Certification Mark for jurisdictions employing the UL or cul Certification (such as Canada), respectively. Last Updated on Questions? Print this page Terms of Use Page Top 2016 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow Up Service. Always look for the Mark on the product. bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 3052&ccnshorttitle=Through penetration+firestop+systems 3/4

38 PRODUCT SPECIFICATION DRAWING Hydroflame Pro Series - Closet Flange Sleeves Closet Flange Sleeve CD Plate (optional) The HOLDRITE Hydroflame Pro Series "Closet Flange Sleeves" are UL Listed Firestop Devices that accept 3" or 4" plastic or no-hub closet flanges and drain pipes. They provide 3-hour "F" & "T" ratings and also "L" & "W" ratings for concrete slabs 2-1/2" and thicker. Sleeves have a mid-body seal and built-in firestop materials. Optional "CD Plate" can be added for use on metal deck forms. Models include #HFP-CF3PL (B), #HFP-CF4PL (B), #HFP-CF3NH (B) and #HFP-CF4NH (B). Product Information: Material: Main Sleeve Body, Base & Safety Cap: Polypropylene. Mid-Body Seal: Thermal Plastic Rubber (TPR); Mold & Fungus resistant per ASTM G-21. Locator Whiskers: Nylon. Fire Ring: 24GA CRS. Firestop Material: UL Listed Intumescent Composite. Patended & Patents Pending. See Hydroflame Pro Series Installation Instructions, Best Practices documents and the lastest UL Fire Resistive Directory file (R25101) for details. THIS INFORMATION IS PROPRIETARY TO HOLDRITE AND IS SUBJECT TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION OR / FAX: / spec_hfp Series, Closet Flange Sleves, pg11 of 12_RevA

39 10/19/2016 XHEZ.F A 1109 Through penetration Firestop Systems System No. F A 1109 XHEZ.F A 1109 Through penetration Firestop Systems Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ Through penetration Firestop Systems XHEZ7 Through penetration Firestop Systems Certified for Canada See General Information for Through penetration Firestop Systems See General Information for Through penetration Firestop Systems Certified for Canada System No. F A 1109 September 12, 2016 ANSI/UL1479 (ASTM E814) CAN/ULC S115 F Rating 3 Hr T Rating 0 Hr L Rating At Ambient Less Than 1 CFM/sq ft L Rating At 400 F Less Than 1 CFM/sq ft F Rating 3 Hr FT Rating 0 Hr FH Rating 3 Hr FTH Rating 0 Hr W Rating Class 1 L Rating At Ambient Less Than 5.1 L/s/m 2 L Rating At 400 F Less Than 5.1 L/s/m 2 bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 1109&ccnshorttitle=Through penetration+firestop+systems 1/4

40 10/19/2016 XHEZ.F A 1109 Through penetration Firestop Systems Configuration A Configuration B bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 1109&ccnshorttitle=Through penetration+firestop+systems 2/4

41 10/19/2016 XHEZ.F A 1109 Through penetration Firestop Systems System tested with a pressure differential of 2.5 Pa between the exposed and the unexposed surfaces with the higher pressure on the exposed side. 1. Floor Assembly Min 4 1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete floor measured over the base of the device. 1A. Floor Assembly (Not Shown) The fire rated concrete and fluted steel deck floor assembly shall be constructed of the materials and in the manner specified in the individual D900 Series designs in the UL Fire Resistance Directory and as summarized below: A. Concrete Config A Min 2 1/2 in. (64 mm) or Config B Min 4 1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete topping, as measured over crests of fluted floor units or the top of the base of the device. B. Steel Floor and Form Units* Composite or noncomposite max 3 in. (76 mm) deep fluted galv units as specified in the individual Floor Ceiling design. Diam of opening cut through fluted floor unit to be maximum 1/4 in. (6 mm) larger than outside diameter of bottom extension portion of firestop device base. Configuration A 2. Firestop Device* Cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. The device shall be installed flush with top and bottom surfaces of floor. For HFP devices the optional accessories (not shown) includes a sleeve extension, aerator adaptor, deck adapter and/or water module installed in accordance with installation instructions. The devices are sized to accommodate installed pipe sizes. Nom Pipe Diam in. (mm) Firestop Devices for Concrete Slab Firestop Devices for Fluted Deck (Not Shown) 3 (76) HFP CF3NH, HFP CF3NHB, HFP M3, HFP M3B, HFP P3, HFP P3B HFP CF3PL, HFP CF3PLB add HFPCD3 3 to 4 (76 to 102) HFP CF4HN, HFP CF4NHB, HFP M4, HFP M4B, HFP P4, HFP P4B HFP CF4PL, HFP CF4PLB add HFPCD4 SECURUS INC, DBA HOLDRITE HydroFlame HFP CFxNH, HFP CFxNHB, HFP CFxPL, HFP CFxPLB HFP M3, HFP M3B, HFP P3, HFP P3B, HFP M4, HFP M4B, HFP P4, HFP P4B Configuration B 2. Firestop Device* Cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. The device shall be installed flush with top and bottom surfaces of floor. Optional accessories (not shown) includes aerator adapter installed in accordance with the installation instructions The devices are sized to accommodate the pipe sizes installed. SECURUS INC, DBA HOLDRITE HydroFlame PS CICF xxxx, PS CXCF xxxx, CD CICF xxxx, CD CXCF xxxx 3. Waste Pipe One nom 3 in. (76 mm) or 4 in. (102 mm) diam cast iron pipe to be installed within the firestop device. Pipe to be installed approximately flush with top surface of floor in accordance with firestop device installation instructions and to be rigidly supported on underside of floor assembly. 4. Toilet Flange Cast iron toilet flange with nominal 7 in. (178 mm) diam top ring and with nominal 4 in. (102 mm) OD throat sized to fit both 3 in. (76 mm) and 4 in. (102 mm) diam drain piping. Toilet flange secured inside metallic pipe (Item 3) and secured to top surface of floor with closet bolts. 5. Water Closet Floor mounted vitreous china water closet. * Indicates such products shall bear the UL or cul Certification Mark for jurisdictions employing the UL or cul Certification (such as Canada), respectively. Last Updated on Questions? Print this page Terms of Use Page Top 2016 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 1109&ccnshorttitle=Through penetration+firestop+systems 3/4

42 10/18/2016 XHEZ.F A 2189 Through penetration Firestop Systems System No. F A 2189 XHEZ.F A 2189 Through penetration Firestop Systems Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ Through penetration Firestop Systems XHEZ7 Through penetration Firestop Systems Certified for Canada See General Information for Through penetration Firestop Systems See General Information for Through penetration Firestop Systems Certified for Canada System No. F A 2189 September 12, 2016 ANSI/UL1479 (ASTM E814) CAN/ULC S115 F Rating 3 Hr T Rating 3 Hr L Rating At Ambient Less Than 1 CFM/sq ft L Rating At 400 F Less Than 1 CFM/sq ft F Rating 3 Hr FT Rating 3 Hr FH Rating 3 Hr FTH Rating 3 Hr W Rating Class 1 L Rating At Ambient Less Than 5.1 L/s/m 2 L Rating At 400 F Less Than 5.1 L/s/m 2 bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 2189&ccnshorttitle=Through penetration+firestop+systems 1/4

43 10/18/2016 XHEZ.F A 2189 Through penetration Firestop Systems Configuration A Configuration B bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 2189&ccnshorttitle=Through penetration+firestop+systems 2/4

44 10/18/2016 XHEZ.F A 2189 Through penetration Firestop Systems System tested with a pressure differential of 2.5 Pa between the exposed and the unexposed surfaces with the higher pressure on the exposed side. 1. Floor Assembly Min 4 1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete floor when measured above base of device excluding any adapters. 1A. Floor Assembly (Not Shown) The fire rated concrete and fluted steel deck floor assembly shall be constructed of the materials and in the manner specified in the individual D900 Series designs in the UL Fire Resistance Directory and as summarized below: A. Concrete Min 2 1/2 in. (64 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete topping, as measured over crests of fluted floor units and above base of device excluding any adapters. B. Steel Floor and Form Units* Composite or noncomposite max 3 in. (76 mm) deep fluted galv units as specified in the individual Floor Ceiling design. Diam of opening cut through fluted floor unit to be maximum 1/4 in. (6 mm) larger than outside diameter of bottom extension portion of firestop device base. 2. Firestop Device* Cast in place firestop device permanently embedded during concrete placement in accordance with accompanying installation instructions. For Conf A HFP devices and optional accessories (not shown) includes sleeve extension, water module, deck adapter and/or aerator adapter installed in accordance with installation instructions. For Conf B devices, optional accessory (not shown) includes aerator adapter installed in accordance with the installation instructions. The device shall be installed flush with top and bottom surfaces of floor. Nom Pipe Diam in. (mm) Conf A Firestop Devices for Concrete Slab Conf A Firestop Devices for Fluted Deck (Not Shown) Conf B Firestop Devices for Concrete Slab Conf B Firestop Devices for Fluted Deck (Not Shown) 3 (76) HFP CF3PL, HFP CF3PLB, HFP P3, HFP P3B add HFPCD3 PS NPCF 0300, PS NPCF , OPS PL 0300, OPS PL CD CPCF 0300, CD NPCF , CD OPS PL 0300, CD OPS PL to 4 (76 to 102) HFP CF4PL, HFP CF4PLB, HFP P4, HFP P4B add HFPCD4 PS NPCF 0400, OPS PL 0400 CD NPCF 0400, CD OPS PL 0400 SECURUS INC, DBA HOLDRITE (Configuration A) HydroFlame HFP CF3PL, HFP CF3PLB, HFP CF4PL, HFP CF4PLB HFP P3, HFP P3B, HFP P4, HFP P4B or (Configuration B) HydroFlame PS CF, PS NPCF 0300, PS NPCF , PS NPCF 0400, CD NPCF 0300, CD NPCF , OPS PL 0300, OPS PL , OPS PL 0400, CD OPS PL 0300, CD OPS PL , CD OPS PL Nonmetallic Pipe One nonmetallic pipe to be installed within the firestop device. Pipe to be installed approximately flush with top surface of floor in accordance with firestop device installation instructions and to be rigidly supported on underside of floor assembly. The following types of pipe may be used: A. Polyvinyl Chloride (PVC) Pipe Nom 3 in. (76 mm) or 4 in. (102 mm) diam Schedule 40 solid or cellular core PVC pipe. B. Acrylonitrile Butadiene Styrene (ABS) Pipe Nom 3 in. (76 mm) or 4 in. (102 mm) diam Schedule 40 solid or cellular core ABS pipe. 4. Toilet Flange PVC or ABS toilet flange with nominal 7 in. (178 mm) diam top ring and with nominal 4 in. (102 mm) OD throat sized to fit both 3 in. (76 mm) and 4 in. (102 mm) diam drain piping. Toilet flange cemented to top of nonmetallic pipe (Item 3) and secured to top surface of floor with closet bolts. 5. Water Closet Floor mounted vitreous china water closet. Install in accordance to installation instructions. * Indicates such products shall bear the UL or cul Certification Mark for jurisdictions employing the UL or cul Certification (such as Canada), respectively. Last Updated on Questions? Print this page Terms of Use Page Top 2016 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a nonmisleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " 2016 UL LLC". bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 2189&ccnshorttitle=Through penetration+firestop+systems 3/4

45 PRODUCT SPECIFICATION DRAWING Hydroflame Pro Series - Floor Drain Sleeve Floor Drain Sleeve The HOLDRITE Hydroflame Pro Series "Floor Drain Sleeves" are designed to accept 2", 3", 4" & 6" cast iron floor drains, with neo-lock style rubber gasket outlet. The Sleeve is cut to the desired height and the Sleeve is secured to the form deck by the installer's prefered method. The Sleeve includes a Mid-Body Seal to enhance water-tightness. (Drain NOT included). Models include #HFP-2CI-DRN thur #HFP-6CI-DRN. Product Information: Material: Main Body & Base: Polypropylene. Mid-Body Seal: Thermal Plastic Rubber (TPR); Mold & Fungus resistant per ASTM G-21. Patented & Patents Pending. See Hydroflame Pro Series Installation Instructions, Best Practices documents and the lastest UL Fire Resistive Directory file (R25101) for details. THIS INFORMATION IS PROPRIETARY TO HOLDRITE AND IS SUBJECT TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION OR / FAX: / spec_hfp Series, Floor Drain Sleeve, pg8 of 12_RevA

46 10/19/2016 XHEZ.F A 1111 Through penetration Firestop Systems System No. F A 1111 XHEZ.F A 1111 Through penetration Firestop Systems Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ Through penetration Firestop Systems XHEZ7 Through penetration Firestop Systems Certified for Canada See General Information for Through penetration Firestop Systems See General Information for Through penetration Firestop Systems Certified for Canada System No. F A 1111 September 12, 2016 ANSI/UL1479 (ASTM E814) CAN/ULC S115 F Rating 2 Hr T Rating 0 Hr F Rating 2 Hr FT Rating 0 Hr FH Rating 2 Hr FTH Rating 0 Hr bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 1111&ccnshorttitle=Through penetration+firestop+systems& 1/3

47 10/19/2016 XHEZ.F A 1111 Through penetration Firestop Systems Configuration A Configuration B bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 1111&ccnshorttitle=Through penetration+firestop+systems& 2/3

48 10/19/2016 XHEZ.F A 1111 Through penetration Firestop Systems System tested with a pressure differential of 2.5 Pa between the exposed and the unexposed surfaces with the higher pressure on the exposed side. 1. Floor Assembly Min 4 1/2 in. (114 mm) thick lightweight or normal weight ( pcf or kg/m 3 ) concrete floor assembly measured above the base of the device. 1A. Floor Assembly (Configuration A, Optional, Not Shown) The fire rated unprotected concrete and steel floor assembly shall be constructed of the materials and in the manner specified in the individual D900 Series designs in the UL Fire Resistance Directory and as summarized below: A. Concrete Min 4 1/2 in. (114 mm) thick reinforced lightweight or normal weight pcf ( kg/m 3 ) concrete measured above the base of the device. B. Steel Floor and Form Units* Composite or non composite max 3 in. (76 mm) deep galv steel fluted units as specified in the individual Floor Ceiling Design. Configuration A 2. Firestop Device* Shower/Floor Drain Cast in place firestop device with cast iron drain body (Item 3) attached to form and permanently embedded during concrete placement in accordance with accompanying installation instructions. For HFP devices the optional accessories (not shown) includes a sleeve extension, aerator adapter deck adapter, midbody seal and/or water module installed in accordance with installation instructions. Devices are sized to accommodate the following nom pipe sizes: Nom Pipe Diam in. (mm) 1 1/2 to 2 (38 to 51) Firestop Devices for Concrete Slab HFP 2CI DRN Firestop Devices for Fluted Deck (Not Shown) add HFPCD2 2 to 3 (51 to 76) HFP 23CI DRN add HFPCD3 3 to 4 (76 to 102) HFP 34CI DRN add HFPCD4 5 to 6 (127 to 152) HFP 6CI DRN add HFPCD6 SECURUS INC, DBA HOLDRITE HFP xci DRN 3. Floor Drain Cast iron drain body secured in or on top of firestop device in accordance with accompanying installation instructions. 4. Drain Piping Max nominal 6 in. (152 mm) diam cast iron drain piping threaded or push type gasket into cast iron drain body. Drain piping rigidly supported at underside of floor with suitable hangers. Configuration B 2. Firestop Device* Shower/Floor Drain Cast in place firestop device with cast iron drain body (Item 3) attached to form and permanently embedded during concrete placement in accordance with accompanying installation instructions. Devices are sized to accommodate the following nom pipe sizes: SECURUS INC, DBA HOLDRITE Type HM CIDK 3. Floor Drain Cast iron drain body secured in top socket of firestop device using stainless steel band clamp provided with firestop device in accordance with manufactures instructions. 4. Drain Piping Nom 2, 3, 4, 5 or 6 in. (51, 76, 102, 127 or 152 mm) diam cast iron drain piping threaded into cast iron drain body. Drain piping rigidly supported at underside of floor with suitable hangers. * Indicates such products shall bear the UL or cul Certification Mark for jurisdictions employing the UL or cul Certification (such as Canada), respectively. Last Updated on Questions? Print this page Terms of Use Page Top 2016 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a nonmisleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " 2016 UL LLC". bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 1111&ccnshorttitle=Through penetration+firestop+systems& 3/3

49 Product Spec Sheet CAST-IN-PLACE HYDROMOUNT DRAIN STAND KIT HM SERIES For use in Concrete floor assemblies with flat form decks Multi-story buildings Dust and fiber free environments such as hospitals, computer centers and laboratories Product Description HydroMount Drain Stand Kits offer water protection for a variety of pipe sizes and types that pass through concrete floors in multi-story buildings HydroMount Drain Stand Kits adapt to a variety of drain types, Zurn Z-415 s, JR Smith, MIFAB, etc, with Neo-Lock gasket type inserts or glue in. Note: Not for use with No-Hub connected type drains. Cast Iron Penetrants 2,3 & 4 pipe sizes Note: Please call to verify the type of drain you will be using adapts to the HydroMount Drain Stand Kit and also refer to the online quote system for the listed part numbers that are applicable to the correct pipe type and size Product Feature & Benefits Simple and quick installation Snug fit holds pipe in place Helps prevent water, smoke, moisture & mold intrusion Helps eliminate rework due to water damage UL F Rated when used with metallic pipe and drain Not for use in Walls or Corrugated metal form decks Safety & Precautions Keep this device out of reach of children and read the Material & Safety Data Sheet Storage of Device Store in a covered or closed area protected from weather and do not stack devices on top of one another other than how they are shipped from manufacture Note: Drain Not Included Installation Instructions (1) Cut the sleeve riser to the correct pour thickness with the drain attached to the drain stand kit as shown in picture above right. (2) After the sleeve has been cut to correct size for concrete pour, attach the mid-body seal to the sleeve using one of the clamps as shown to the right. Attach the drain body by pushing it into the top of the mid-body seal and then secure the mid-body seal to the drain body with the remaining clamp as shown above right. (3) Place the drain stand and drain on form deck using the alignment marks on the base to the layout lines on the deck so the drain will be centered and installed correctly on the form deck. Secure drain stand to form deck through the slots on the base with appropriate nails or screws. (4) After concrete pour and the forms are removed, you can now install pipe up through the sleeve and into the bottom of the drain assembly. Note: In some cases where needed, you can ease the insertion of the pipe by using the appropriate lubrication on the mid-body seal and seal on the drain itself to make it easier for the pipe to be inserted through these seals. (5) To ensure that the water-tight feature of the W-rated sleeving systems perform as required, it is recommended that piping be confirmed to be within manufacturer s specified dimensional tolerances, prior to installing the penetrating pipe into the sleeve. For nohub cast iron pipe, where a water-tight seal is required and 1) the pipe outer surface is very rough or irregular, or 2) the pipe O.D. is in excess of 25/1000 inch (0.025 ) smaller than pipe manufacturer s nominal O.D. specification, it may be necessary to add a bead of compatible silicone sealant around pipe for a fully water-tight seal. Also, due to its smaller O.D. specification, a water-tight seal cannot be guaranteed without using silicone sealant on service weight cast iron pipe. Be sure to use a sealant that is compatible with both the PVC sleeve riser and the pipe. Note: HOLDRITE HYDROFLAME is not responsible for sleeve performance when installation instructions are not followed and will not be liable for damage to property or persons due to improper installation of materials or through attempts to utilize the material under conditions which exceed the designed capacities. Purchaser agrees to indemnify and hold us harmless for any and all claims, liabilities, damages, costs and expenses asserted against us or incurred by us because of injuries to persons or damages to property resulting from the improper installation or misuse of the material. For additional warranty limitations, refer to HOLDRITE s Limited Warranty dated 1/15/13. Job Name: Date: Part#: Product Submittal Architect/Owner: Contractor: Qty: Notes: spec_hfhds_revg

50 10/19/2016 XHEZ.F A 1111 Through penetration Firestop Systems System No. F A 1111 XHEZ.F A 1111 Through penetration Firestop Systems Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ Through penetration Firestop Systems XHEZ7 Through penetration Firestop Systems Certified for Canada See General Information for Through penetration Firestop Systems See General Information for Through penetration Firestop Systems Certified for Canada System No. F A 1111 September 12, 2016 ANSI/UL1479 (ASTM E814) CAN/ULC S115 F Rating 2 Hr T Rating 0 Hr F Rating 2 Hr FT Rating 0 Hr FH Rating 2 Hr FTH Rating 0 Hr bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 1111&ccnshorttitle=Through penetration+firestop+systems& 1/3

51 10/19/2016 XHEZ.F A 1111 Through penetration Firestop Systems Configuration A Configuration B bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 1111&ccnshorttitle=Through penetration+firestop+systems& 2/3

52 10/19/2016 XHEZ.F A 1111 Through penetration Firestop Systems System tested with a pressure differential of 2.5 Pa between the exposed and the unexposed surfaces with the higher pressure on the exposed side. 1. Floor Assembly Min 4 1/2 in. (114 mm) thick lightweight or normal weight ( pcf or kg/m 3 ) concrete floor assembly measured above the base of the device. 1A. Floor Assembly (Configuration A, Optional, Not Shown) The fire rated unprotected concrete and steel floor assembly shall be constructed of the materials and in the manner specified in the individual D900 Series designs in the UL Fire Resistance Directory and as summarized below: A. Concrete Min 4 1/2 in. (114 mm) thick reinforced lightweight or normal weight pcf ( kg/m 3 ) concrete measured above the base of the device. B. Steel Floor and Form Units* Composite or non composite max 3 in. (76 mm) deep galv steel fluted units as specified in the individual Floor Ceiling Design. Configuration A 2. Firestop Device* Shower/Floor Drain Cast in place firestop device with cast iron drain body (Item 3) attached to form and permanently embedded during concrete placement in accordance with accompanying installation instructions. For HFP devices the optional accessories (not shown) includes a sleeve extension, aerator adapter deck adapter, midbody seal and/or water module installed in accordance with installation instructions. Devices are sized to accommodate the following nom pipe sizes: Nom Pipe Diam in. (mm) 1 1/2 to 2 (38 to 51) Firestop Devices for Concrete Slab HFP 2CI DRN Firestop Devices for Fluted Deck (Not Shown) add HFPCD2 2 to 3 (51 to 76) HFP 23CI DRN add HFPCD3 3 to 4 (76 to 102) HFP 34CI DRN add HFPCD4 5 to 6 (127 to 152) HFP 6CI DRN add HFPCD6 SECURUS INC, DBA HOLDRITE HFP xci DRN 3. Floor Drain Cast iron drain body secured in or on top of firestop device in accordance with accompanying installation instructions. 4. Drain Piping Max nominal 6 in. (152 mm) diam cast iron drain piping threaded or push type gasket into cast iron drain body. Drain piping rigidly supported at underside of floor with suitable hangers. Configuration B 2. Firestop Device* Shower/Floor Drain Cast in place firestop device with cast iron drain body (Item 3) attached to form and permanently embedded during concrete placement in accordance with accompanying installation instructions. Devices are sized to accommodate the following nom pipe sizes: SECURUS INC, DBA HOLDRITE Type HM CIDK 3. Floor Drain Cast iron drain body secured in top socket of firestop device using stainless steel band clamp provided with firestop device in accordance with manufactures instructions. 4. Drain Piping Nom 2, 3, 4, 5 or 6 in. (51, 76, 102, 127 or 152 mm) diam cast iron drain piping threaded into cast iron drain body. Drain piping rigidly supported at underside of floor with suitable hangers. * Indicates such products shall bear the UL or cul Certification Mark for jurisdictions employing the UL or cul Certification (such as Canada), respectively. Last Updated on Questions? Print this page Terms of Use Page Top 2016 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a nonmisleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " 2016 UL LLC". bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 1111&ccnshorttitle=Through penetration+firestop+systems& 3/3

53 PRODUCT SPECIFICATION DRAWING Hydroflame Pro Series - Cable & Line-Set Sleeves Cable & Line-Set Sleeve CD Plate (optional) The HOLDRITE Hydroflame Pro Series "Cable & Line-Set Sleeves" are UL Listed Firestop Devices that provide 3- hour fire ratings (as well as "T", "L" & "W" ratings, when installed per UL system drawings). Telescoping and nontelescoping versions are available. The Sleeves are approved to accept up to 45% cable fill, refrigeration line-sets and multiple small pipes. Six sleeve sizes/varieties available. Optional "CD Plate" can be used for metal deck forms. Models include #HFP-CSM2, #HFP-CSM3, #HFP-CSM2B, #HFP-CSM3B, #HFP-LSP3 and #HFP-LSP3B. Product Information: Material: Main Sleeve Body, Base & Safety Cap: Polypropylene. Mid-Body Seal: Thermal Plastic Rubber (TPR); Mold & Fungus resistant per ASTM G-21. Locator Whiskers: Nylon. Fire Ring: 24GA CRS. Firestop Material: UL Listed Intumescent Composite. Patended & Patents Pending. See Hydroflame Pro Series Installation Instructions, Best Practices documents and the lastest UL Fire Resistive Directory file (R25101) for details. THIS INFORMATION IS PROPRIETARY TO HOLDRITE AND IS SUBJECT TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION OR / FAX: / spec_hfp Series, Cable & Line-Set Sleeves, pg10 of 12_RevA

54 10/19/2016 XHEZ.F A 8034 Through penetration Firestop Systems System No. F A 8034 XHEZ.F A 8034 Through penetration Firestop Systems Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ Through penetration Firestop Systems XHEZ7 Through penetration Firestop Systems Certified for Canada See General Information for Through penetration Firestop Systems See General Information for Through penetration Firestop Systems Certified for Canada System No. F A 8034 September 12, 2016 ANSI/UL1479 (ASTM E814) CAN/ULC S115 F Rating 3 Hr T Rating 1/4 Hr L Rating At Ambient Less Than 1 CFM/ft 2 L Rating At 400 F Less Than 1 CFM/ft 2 F Rating 3 Hr FT Rating 1/4 Hr FH Rating 3 Hr FTH Rating 1/4 Hr W Rating Class 1 L Rating At Ambient Less Than 5.1 L/s/m 2 L Rating At 400 F Less Than 5.1 L/s/m 2 bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 8034&ccnshorttitle=Through penetration+firestop+systems 1/5

55 10/19/2016 XHEZ.F A 8034 Through penetration Firestop Systems Configuration A Configuration B bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 8034&ccnshorttitle=Through penetration+firestop+systems 2/5

56 10/19/2016 XHEZ.F A 8034 Through penetration Firestop Systems Configuration C System tested with a pressure differential of 2.5 Pa between the exposed and the unexposed surfaces with the higher pressure on the exposed side. 1. Floor Assembly Min 4 1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete. 1A. Alternate Floor Assembly (Not Shown) The fire rated unprotected concrete and steel deck floor assembly shall be constructed of the material and in the manner specified in the individual D900 Series designs in the UL Fire Resistance Directory and as summarized below: A. Concrete Min 4 1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) concrete, as measured from the top plane of the steel floor units. When concrete thickness is min 4 1/2 in. (114 mm), the F and FH Ratings are 3 hr. B. Steel Floor and Form Units* Composite or non composite max 3 in. (76 mm) deep galv steel fluted units as specified in the individual Floor Ceiling Design. Configurations A and B 2. Firestop Device* Cast in place firestop device permanently embedded during concrete placement or grouted in concrete assembly in accordance with accompanying installation instructions. For HFP devices in configuration A the optional accessories (not shown) includes a sleeve extension and deck adapter, installed in accordance with manufactures instructions. Conf A Firestop Devices for Concrete Slab Conf B Firestop Devices for Concrete Slab Conf B Firestop Devices for Fluted Deck (Not Shown) Conf A Firestop Devices for Fluted Deck (Not Shown) HFP LSP3, HFP LSP3B PS LS 0300 CD LS 0300 add HFPCD3 SECURUS INC, DBA HOLDRITE HydroFlame PS LS, CD LS HFP LS3, HFP LS3B, HFP P3, HFP P3B 3. Through Penetrants Pipes, tubing or cable to be bundled within the opening. The space between penetrants and the space between the penetrants and the inside of the firestop device (Item 2) at top of floor shall be min 1/4 in. (6 mm). Penetrants to be rigidly supported on both sides of floor assembly. The following types and sizes of penetrants may be used: bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 8034&ccnshorttitle=Through penetration+firestop+systems 3/5

57 10/19/2016 XHEZ.F A 8034 Through penetration Firestop Systems A. Metallic Pipes One or two of the following types and sizes of metallic pipe or tubing may be used: 1. Copper Tubing Nom 3/4 in. (19 mm) diam (or smaller) Type L (or heavier) copper tubing. 2. Copper Pipe Nom 3/4 in. (19 mm) diam (or smaller) Regular (or heavier) copper pipe. All metallic pipes or tubing larger than nom 1/2 in. (13 mm) diam shall be provided with pipe covering (Item 4). B. Polyvinyl Chloride (PVC) Pipe A max of one nom 1 in. (25 mm) diam (or smaller) Schedule 40 solid core PVC pipe for use in closed (process or supply) piping systems. C. Cable One max 8/C No. 18 AWG (or smaller) thermostat cable; XLPE or PVC insulation with XLPE or PVC jacket. Configuration C 2. Firestop Device* Cast in place firestop device permanently embedded during concrete placement or grouted in concrete assembly in accordance with accompanying installation instructions. For HFP devices in configuration C the optional accessories (not shown) includes a sleeve extension and deck adapter, installed in accordance with manufactures instructions. Conf C Firestop Devices for Concrete Slab HFP P3, HFP P3B Conf C Firestop Devices for Fluted Deck (Not Shown) add HFPCD3 SECURUS INC, DBA HOLDRITE HydroFlame HFP P3, HFP P3B 3. Through Penetrants (For use with HFP3, and HFP3B devices only) Max of two of the same pipes, tubing to be bundled within the opening. The space between penetrants and the space between the penetrants and the inside of the firestop device (Item 2) at top of floor shall be min 1/4 in. (6 mm). Penetrants to be rigidly supported on both sides of floor assembly. The following types and sizes of penetrants may be used: A. Cross Linked Polyethylene (PEX) Tubing A max of two nom 1 in. (25 mm) diam (or smaller) SDR 9 PEX tubing for use in closed (process or supply) piping systems. B. Polyvinyl Chloride (PVC) Pipe Nom 1 in. (25 mm) diam (or smaller) Schedule 40 solid core PVC pipe, for use in closed (process or supply) piping systems. C. Rigid Nonmetallic Conduit+ Nom 1 in. (25 mm) diam (or smaller) Schedule 40 PVC conduit installed in accordance with the National Electrical Code (NFPA No. 70). D. Chlorinated Polyvinyl Chloride (CPVC) Pipe Nom 1 in. (25 mm) diam (or smaller) SDR13.5 (or heavier) or Sch 40 CPVC pipe for use in closed (process or supply) piping systems. 4. Pipe Covering The following types and sizes of pipe coverings may be used with the metallic pipes: A. Pipe Covering Nom 1/2 in. (13 mm) thick hollow cylindrical heavy density glass fiber units jacketed on the outside with an all service jacket. Longitudinal joints sealed with metal fasteners or factory applied self sealing lap tape. Transverse joints secured with metal fasteners or with butt tape supplied with product. See Pipe and Equipment Covering Materials (BRGU) category in the Building Materials Directory for names of manufacturers. Any pipe covering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a smoke Developed Index of 50 or less may be used. B. PVC Jacket++ An additional PVC jacket, supplied in sheet form, shall be tightly wrapped around the all service jacket on the pipe covering (Item 4A) with the longitudinal seam continuously sealed using the self sealing lap tape or adhesive supplied with the jacket. The jacket is to be nom 48 in. (1.22 m) wide by nom 20 or 30 mil (0.5 or 0.8 mm) thick. The jacket shall extend downward into and/or through the opening from a point 36 to 40 in. (0.91 to 1.02 m) above the top surface of the floor assembly. The PVC jacket must be used for the W Rating to apply. See Plastics (QMFZ2) category in the Plastics Recognized Component Directory for names of manufacturers. Any Recognized Component plastic material meeting the above specifications and having a UL 94 Flammability Classification of 94 5VA may be used. C. Tube Insulation Plastics+ Nom 1/2 in. (13 mm) thick acrylonitrile butadiene/polyvinyl chloride (AB/PVC) flexible foam furnished in the form of tubing. See Plastics (QMFZ2) category in the Plastics Recognized Component Directory for names of manufacturers. Any Recognized Component tube insulation material meeting the above specifications and having a UL 94 Flammability Classification of 94 5A may be used. bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 8034&ccnshorttitle=Through penetration+firestop+systems 4/5

58 10/19/2016 XHEZ.F A 8034 Through penetration Firestop Systems 5. Packing Material Min 2 in. (51 mm) depth of min 4 pcf (64 kg/m 3 ) mineral wool batt insulation firmly packed into top of firestop device as a permanent form. Packing material to be recessed from top surface of floor as required to accommodate the required thickness of fill material. 6. Fill, Void or Cavity Material* Sealant Min 1/4 in. (6 mm) thickness of sealant applied within the annulus, flush with the top surface of floor. Sealant to be forced into interstices of AC lineset to max extent possible. Config B Only Sealant to lap min 1/2 in. (13 mm) onto top surface of concrete around perimeter of firestop device. 3M COMPANY 3M FIRE PROTECTION PRODUCTS FB 1000 NS, FB 3000 WT or FB 1003 SL RECTORSEAL Metacaulk 835+ or Biotherm 100 or 200 * Indicates such products shall bear the UL or cul Certification Mark for jurisdictions employing the UL or cul Certification (such as Canada), respectively. + Bearing the UL Listing Mark ++ Bearing the UL Recognized Component Mark Last Updated on Questions? Print this page Terms of Use Page Top 2016 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a nonmisleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " 2016 UL LLC". bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 8034&ccnshorttitle=Through penetration+firestop+systems 5/5

59 PRODUCT SPECIFICATION DRAWING Hydroflame Pro Series - Shower Drain Sleeve Shower Drain Sleeve The HOLDRITE Hydroflame Pro Series "Shower Drain Sleeve" (#HFP-SH2-DRN) is ideal for 2 drain bodies that are recessed into the concrete floor, such as with a shower pan or shower stall. This is a UL Listed Firestop Device that includes a water-tight mid-body seal and built-in firestop materials. The Sleeve is adjustible in height for slabs 5" and thicker and provides a 3-hour F-rating. Optional "CD Plate" can be used when mounting to metal pan deck forms. Upper assembly includes a styrofoam insert pad, to block concrete during pour. Product Information: Material: Main Sleeve Body, Base & Drain Receiver: Polypropylene Mid-Body Seal: Thermal Plastic Rubber (TPR); Mold & Fungus resistant per ASTM G-21. Firestop Material: UL Listed Intumescent Composite Insert: Styrofoam Patended & Patents Pending See Hydroflame Pro Series Installation Instructions, Best Practices documents and the lastest UL Fire Resistive Directory file (R25101) for details. THIS INFORMATION IS PROPRIETARY TO HOLDRITE AND IS SUBJECT TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION OR / FAX: / spec_hfp Series, Shower Drain Sleeve, pg9 of 12_RevA

60 10/19/2016 XHEZ.F A 2190 Through penetration Firestop Systems System No. F A 2190 XHEZ.F A 2190 Through penetration Firestop Systems Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ Through penetration Firestop Systems XHEZ7 Through penetration Firestop Systems Certified for Canada See General Information for Through penetration Firestop Systems See General Information for Through penetration Firestop Systems Certified for Canada System No. F A 2190 September 12, 2016 ANSI/UL1479 (ASTM E814) CAN/ULC S115 F Rating 3 Hr T Rating 0 Hr F Rating 3 Hr FT Rating 0 Hr FH Rating 3 Hr FTH Rating 0 Hr bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 2190&ccnshorttitle=Through penetration+firestop+systems 1/3

61 10/19/2016 XHEZ.F A 2190 Through penetration Firestop Systems Configuration A Configuration B System tested with a pressure differential of 2.5 Pa between the exposed and the unexposed surfaces with the higher pressure on the exposed side. 1. Floor Assembly Min 5 in. (127 mm) thick lightweight or normal weight ( pcf or kg/m 3 ) concrete floor assembly. Configuration A 2. Firestop Device* Shower/Floor Drain Cast in place firestop device with polished brass or chromed steel shower drain or floor drain strainer attached to form and permanently embedded during concrete placement in accordance with accompanying installation instructions. For HFP devices optional accessory (not shown) includes sleeve extension installed in accordance with installation instructions. SECURUS INC, DBA HOLDRITE HydroFlame, HFP SH2 DRN 3. Drain Piping Nom 1 1/2 to 2 in. (38 to 51 mm) diam Schedule 40 PVC drain piping cemented, threaded or push type gasket into bottom socket of Shower/Floor Drain fitting. Different drain pipe types (cast iron, ABS, copper, etc.) may also be connected to the shower drain pipe by extending drain pipe min 2 inches (51 mm) below the floor and then using the appropriate fittings/bushings/compression fittings to adapt to these different types of drain pipe. Drain piping rigidly supported at underside of floor with suitable hangers. Configuration B 2. Firestop Device* Shower/Floor Drain Cast in place firestop device with polished brass or chromed steel shower drain or floor drain strainer attached to form and permanently embedded during concrete placement in accordance with accompanying installation instructions. SECURUS INC, DBA HOLDRITE HydroFlame PS SD Drain Piping Nom 2 in. (51 mm) diam Schedule 40 PVC drain piping cemented into bottom socket of firestop device. Different drain pipe types (cast iron, ABS, copper, etc.) can be connected to the shower drain base by cementing a short piece of PVC pipe into the bottom of the shower drain base so it extends min 2 in. (51 mm) below the floor and then using the appropriate fittings/bushings to adapt to these types of drain pipe. When the tail piece of the shower drain assembly extends below the slab, cement or compression fittings/bushings can be used to adapt to the different drain pipe types. Drain piping rigidly supported at underside of floor with suitable hangers. bin/xyv/template/lisext/1frame/showpage.html?name=xhez.f A 2190&ccnshorttitle=Through penetration+firestop+systems 2/3

62 Product Spec Sheet CAST-IN-PLACE SHOWER DRAIN SLEEVE PS-SD-0200 For use in Concrete floor assemblies with flat form decks Dust and fiber free environments such as hospitals, computer centers and laboratories Product Description HydroFlame shower drain sleeves offer fire protection built into the sleeve for 2 size pipe that passes through concrete floors in multi-story buildings These shower drain sleeves are delivered to the job site ready to accept the pipe and shower drain by solvent cementing them to the inside top of the shower drain sleeve HydroFlame shower drain sleeves appreciably reduce job time and material expenses by not requiring additional steps, such as mineral wool and caulking Nonmetallic and Metallic Pipe 2 drain pipe size: ABS, ccabs, PVC, ccpvc, Cast Iron, Copper Product Feature & Benefits Simple and quick installation Built in fire protection No need for mineral wool or caulkings Not for use in Walls Safety & Precautions Keep this device out of reach of children Read the Material & Safety Data Sheet Storage of Device Store in a covered or closed area protected from weather Do not stack devices on top of one another other than how they are shipped from manufacture Note: The shower drain sleeve does not come with pipe or the shower drain, you get the shower drain sleeve that will accommodate the pipe and drain supplied by others. Note: Shower Drain and Riser Pipe Not Included Technical Data for HYDROFLAME Firestop Material Physical Properties Color: Gray/Black Heat Expansion (Intumescence) Expansion begins: 410 F (210 C) Significant expansion: 555 F (290 C) Free expansion: 25 times (5 662 [350 C]) Weatherability (Tested to ASTM G23 and G53) Test Condition Temperature/Humidity 90 F (32 C)/90% Time 120 Days After Exposure No change in expansion Surface Burning Characteristics (ASTM E84, UL 723) Flame spread index: 0 Smoke development index: 5 Testing Data UL Fire Tested & Listed to UL 1479 (ASTM E814) Standards F Rating UL 3 Hours Installation Instructions (1) The minimum concrete pour thickness for the shower drain application is 5 inch, to achieve this height the shower drain will be cemented (glued) into the top of the shower drain base. For concrete slab thicknesses greater than 5 inch a 2 inch PVC coupling will be cemented (glued) into the top of the shower drain base from our factory. To achieve the appropriate height for slab thickness cement (glue) 2 inch schedule 40 PVC pipe into the 2 inch PVC coupling at the top of the shower drain base that has been cut for slab thickness. (2) Align the hatch marks on lower shower drain base to layout lines on form deck to center the sleeve for the pipe that will be attached to the drain. Attach the sleeve to deck using the nail holes provided in the lower shower drain base. Note: It is recommended to use 6 penny nails through the nail slots to secure device to the deck. You may use appropriate staples to secure the device to form deck by straddling the nail slots on the edge of the base. DO NOT USE SCREWS TO SECURE THE DEVICE TO FORM DECK BECAUSE THE FORM DECK OR DEVICE COULD BE DAMAGED. A Minimum of 4 holes should be used for nailing the sleeve to the wood form deck. The drain face will need to be taped off to prevent concrete from entering the drain piping and shower drain. (3) Pour the concrete slab around the device to the appropriate slab thickness. (4) As the form deck is removed after the appropriate concrete curing time has been accomplished, the nails can be pulled through the nail slots on the base, as designed. (5) Remove protective tape from drain and install drain cover. (6) Drain pipe connects to shower drain base, 2 inch schedule 40 PVC drain pipe can be cemented (glued) into coupling or shower drain itself. Different drain pipe types (cast iron, ABS, copper etc...) can be connected to the shower drain base by gluing a short piece of PVC pipe into the bottom of the shower drain base so it extends 2 inches below the slab, then use the appropriate fittings/bushings to adapt to these type of drain pipes (cast iron, ABS, copper etc..) When the tail piece of the shower drain assembly (by others) extends below the slab you can use glue or compression fittings/bushings to adapt to these drain types (cast iron, ABS, copper etc..) Please refer to UL listing XHEA.F-A-2190 for full details. Note: HOLDRITE HYDROFLAME is not responsible for sleeve performance when installation instructions are not followed and will not be liable for damage to property or persons due to improper installation of materials or through attempts to utilize the material under conditions which exceed the designed capacities. Purchaser agrees to indemnify and hold us harmless for any and all claims, liabilities, damages, costs and expenses asserted against us or incurred by us because of injuries to persons or damages to property resulting from the improper installation or misuse of the material. For additional warranty limitations, refer to HOLDRITE s Limited Warranty dated 1/15/13. Job Name: Date: Part#: Product Submittal Architect/Owner: Contractor: Qty: Notes: Note #1 & 2 Note #3 Note #4 Notes #5 & 6 spec_hfsds_revh

Joint Systems. System No. FF-D-0044

Joint Systems. System No. FF-D-0044 XHBN.FF-D-0044 System No. FF-D-0044 November 05, 2003 Assembly Rating 2 Hr Nom Joint Width 1 in. Class II and III Movement Capabilities 50% Compression or Extension 1. Floor or Wall Assembly Reinforced

More information

DECEMBER Phone: Fax:

DECEMBER Phone: Fax: DECEMBER 007 TM system components www.nsiindustries.com Phone: 800.1.587 Fax: 800.81.5566 Table of Contents FireStop System Components Intumescent Caulk...1 Silicone...1 Silicone SL... FireStop81.... FireBlock16...

More information

Design No. L565. Design No. L565

Design No. L565. Design No. L565 1 of 5 3/17/2015 6:18 PM Design No. L565 BXUV.L565 Fire Resistance Ratings - ANSI/UL 263 Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted

More information

FIRESTOP SUBMITTAL PACKAGE

FIRESTOP SUBMITTAL PACKAGE FIRESTOP SUBMITTAL PACKAGE PLUMBING Materials FS-ONE Intumesent Caulk Includes: Technical and Installation Data UL Certificate of Compliance LEED information MSDS UL Details Gypsum Wall Assemblies W-L-1054

More information

Firestopping Submittal Package

Firestopping Submittal Package Firestopping Submittal Package Project: Architect: General Contractor: Installation Contractor: Distributor (and Contact): Manufacturer's Representative: Rectorseal - Technical Services Ph (713) 263-8001

More information

SLOTTED STUD WIND-LOAD & NON-LOAD BEARING DEFLECTION WALL SYSTEM. U.L. FIRE RATED Head-of-Wall Joint Systems

SLOTTED STUD WIND-LOAD & NON-LOAD BEARING DEFLECTION WALL SYSTEM. U.L. FIRE RATED Head-of-Wall Joint Systems SLOTTED STUD WIND-LOAD & NON-LOAD BEARING DEFLECTION WALL SYSTEM U.L. FIRE RATED Head-of-Wall Joint Systems 1-800-275-2279 STEELER INC. SLOTTED STUD 1-800-275-2279 The STEELER SLOTTED STUD is an innovative

More information

Fire Barrier Duct Wrap 615+

Fire Barrier Duct Wrap 615+ Fire Barrier Duct Wrap 615+ Duct Wrap Fire Protection System for Commercial Kitchen Grease and Ventilation Air Ducts Product Data Batts and blankets for use in fire resistive duct assemblies see UL fire

More information

3M Fire Barrier Duct Wrap 615+ Product Data Sheet and Installation Guide (Condensed Version)

3M Fire Barrier Duct Wrap 615+ Product Data Sheet and Installation Guide (Condensed Version) M Fire Barrier Duct Wrap + Product Data Sheet and Installation Guide (Condensed Version) FIRE BARRIER UP TO Fire Protection HOUR FLEXIBLE WRAP GREASE & AIR DUCT Fire Protection. Product Description M Fire

More information

Pyroscat Duct Wrap XL

Pyroscat Duct Wrap XL Datasheet Code US: - 0 Thermal Ceramics is a business of Morgan Advanced Materials * Commonly referred to test method CA Section 00 is CDPH Standard Method for the Testing and Evaluation of Volatile Organic

More information

SECTION HVAC INSULATION

SECTION HVAC INSULATION PART 1 GENERAL 1.1 SUMMARY SECTION 23 07 00 HVAC INSULATION A. Section Includes: 1. Ductwork insulation. 2. Duct liner. 3. Insulation jackets. 4. Equipment insulation 5. Piping system insulation. 6. Insulation

More information

Design No. P922 September 26, Restrained Assembly Rating 1, 1-1/2 or 2 Hr (See Items 6, 7) Unrestrained Assembly Rating 0 Hr (See Item 6)

Design No. P922 September 26, Restrained Assembly Rating 1, 1-1/2 or 2 Hr (See Items 6, 7) Unrestrained Assembly Rating 0 Hr (See Item 6) Design No. P922 September 26, 2003 Restrained Assembly Rating 1, 1-1/2 or 2 Hr (See Items 6, 7) Unrestrained Assembly Rating 0 Hr (See Item 6) Unrestrained Beam Rating 1, 1-1/2 or 2 Hr (See Item 7) 1.

More information

ICC-ES Evaluation Report Reissued May 1, 2010 This report is subject to re-examination in two years.

ICC-ES Evaluation Report Reissued May 1, 2010 This report is subject to re-examination in two years. ICC-ES Evaluation Report ESR-1255 Reissued May 1, 2010 This report is subject to re-examination in two years. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

FIRESTOP SUBMITTAL PACKAGE

FIRESTOP SUBMITTAL PACKAGE FIRESTOP SUBMITTAL PACKAGE HVAC Materials FS-ONE Intumesent Caulk CP 606 Acrylic Includes: Technical and Installation Data UL Certificate of Compliance LEED information MSDS UL Details Concrete Assemblies

More information

Fig. 1 - Standard Clevis Hanger

Fig. 1 - Standard Clevis Hanger Revision 10/24/2007 Fig. 1 - Standard Clevis Hanger Component of State of California OSHPD Approved Seismic Restraints System Size Range Size 1/2" thru 36" pipe. Function Recommended for the suspension

More information

3M CS-195+ Composite Sheet Product Description

3M CS-195+ Composite Sheet Product Description Product Data Sheet 3M Product Description 3M Fire Barrier is a one-part composite system comprised of four components. The heart of the system is an organic/ inorganic, fire-resistive elastomeric sheet.

More information

Through-Fastener Panel UL Listing documentation

Through-Fastener Panel UL Listing documentation Through-Fastener Panel UL Listing documentation Class-4 Impact Rating Class-90 Fire Rating Tensile Strength: Grade 80/E Coil Thickness Range for 29 ga.: 0.0142 0.015 Coil Thickness Range for 26 ga.: 0.0182

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MINERAL FIBER FIREPROOFING REPORT HOLDER: UNIFRAX I LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MINERAL FIBER FIREPROOFING REPORT HOLDER: UNIFRAX I LLC 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2224 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00

More information

FireMaster FastWrap XL

FireMaster FastWrap XL Datasheet Code US: 7-14-36 MSDS Code US: 406 009 Morgan Thermal Ceramics, a business within the Morgan Ceramics Division of The Morgan Crucible Company plc * Commonly referred to test method CA Section

More information

UL Online Certifications Directory

UL Online Certifications Directory Design No. N782 August 03, 2006 Restrained Beam Ratings 1, 1-1/2, 2, 3 and 4 Hr Unrestrained Beam Ratings 1, 1-1/2, 2, 3 and 4 Hr Load Restricted for Canadian Applications See Guide BXUV7 1. Steel Beam

More information

Tehnical Data Sheet Astro Intu Mastic. UIC of product-type: INTUM CPR-JA5015

Tehnical Data Sheet Astro Intu Mastic. UIC of product-type: INTUM CPR-JA5015 1121 Astroflame Fireseals Ltd Unit 8 The I O Centre 14 1121-CPR-JA5015 ETA-14/0049 ETA-14/0050 ETAG 026-Part 1 ETAG 026-Part 2 ETAG 026-Part 3 MASTIC see ETA-14/0049 & ETA- 14/0050 for relevant characteristics

More information

FireMaster FastWrap XL

FireMaster FastWrap XL Datasheet Code US: 7--6 MSDS Code US: 06 009 Morgan Thermal Ceramics, a business within the Morgan Ceramics Division of The Morgan Crucible Company plc Grease Duct Enclosure System Air Ventilation Duct

More information

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT SECTION 230548 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Elastomeric Isolation pads. 2. Elastomeric Isolation mounts. 3. [Freestanding] [Restrained] [Freestanding and restrained]

More information

1. Division 23 Section "Hangers and Supports for HVAC Piping and Equipment" for pipe insulation shields and protection saddles.

1. Division 23 Section Hangers and Supports for HVAC Piping and Equipment for pipe insulation shields and protection saddles. SECTION 23 07 19 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

PASSIVE FIRE PROTECTION PRODUCTS

PASSIVE FIRE PROTECTION PRODUCTS OCTOBER 2016 PASSIVE FIRE PROTECTION PRODUCTS www.allproof.com CONTENTS FIRE TESTING 1 ADVANCED INTUMESCENT 2 ALLPROOF INTUMESCENT TECHNOLOGY: 2 LOW PROFILE S 3 CONCRETE SLAB TEST RESULTS: 4 FLOOR WASTE

More information

FIRE-HALT SEALANT/SETTING COMPOUND

FIRE-HALT SEALANT/SETTING COMPOUND FIRE-HALT SEALANT/SETTING COMPOUND Noncombustible fast-setting compound for use as a firestop sealant for penetrations. Product Overview Fire-Halt Sealant is a noncombustible 1, gypsum-based fast-setting

More information

E. Manufacturers Standardization Society of the Valve and Fittings Industry:

E. Manufacturers Standardization Society of the Valve and Fittings Industry: SECTION 230529 - HANGERS AND SUPPORTS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe hangers and supports. 2. Hanger rods. 3. Inserts. 4. Flashing. 5. Equipment curbs. 6. Sleeves. 7. Mechanical

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC. 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1143 Reissued 04/2017 This report is subject to renewal 04/2018. DIVISION: 07 00 00 THERMAL

More information

SECTION THROUGH-PENETRATION FIRE STOP SYSTEMS

SECTION THROUGH-PENETRATION FIRE STOP SYSTEMS SECTION 07841 THROUGH-PENETRATION FIRE STOP SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Section includes firestopping and through-penetration system materials and accessories; firestopping tops of

More information

A. Source Limitations: Obtain each type of building insulation through one source.

A. Source Limitations: Obtain each type of building insulation through one source. SECTION 07210 - BUILDING INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

GOWANDA, NEW YORK SEPTEMBER 18, 2008 ARCH PROJECT NO

GOWANDA, NEW YORK SEPTEMBER 18, 2008 ARCH PROJECT NO SECTION 07210 BUILDING INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SPECIFICATION DIVISION 7 NUMBER SECTION DESCRIPTION DIVISION 07 THERMAL AND MOISTURE PROTECTION SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

SPECIFICATION DIVISION 7 NUMBER SECTION DESCRIPTION DIVISION 07 THERMAL AND MOISTURE PROTECTION SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS BuildingName The Description of the Project P00000000 0000 DOCUMENTS Title Page Table of Contents Instruction to Bidders Form of Proposal Equal Opportunity Statement Form of Guarantee Supplemental General

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 1319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS SECTION 270528 PATHWAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Communications equipment coordination and installation. 2. Sleeves for pathways and cables. 3. Raceway

More information

FastWrap+ 1 1 /2 Commercial Kitchen Grease Duct Air Ventilation Duct

FastWrap+ 1 1 /2 Commercial Kitchen Grease Duct Air Ventilation Duct FastWrap+ 1 1 /2 Commercial Kitchen Grease Duct Air Ventilation Duct Fire Protection Systems Product Data and Installation Guide NFPA 96 IMC 1. Product Description - New and Improved FastWrap+ Thermal

More information

A. Pipe Supports: ANSI B 31.1, Power Piping. B. Automatic Sprinkler Pipe Supports: Refer to Section

A. Pipe Supports: ANSI B 31.1, Power Piping. B. Automatic Sprinkler Pipe Supports: Refer to Section SECTION 15140 SUPPORTS, ANCHORS, AND SEALS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract including General and Supplementary Conditions, Division 1 Specification

More information

Firestopping Submittal Package

Firestopping Submittal Package Firestopping Submittal Package Project: Architect: General Contractor: Installation Contractor: Distributor (and Contact): WP Contractors - Concrete Control Joints - BF 750 Manufacturer's Representative:

More information

EcoTouch Insulation with PureFiber Technology

EcoTouch Insulation with PureFiber Technology PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.

More information

Smarter. Safer. Leaner.

Smarter. Safer. Leaner. Smarter. Safer. Leaner. Fast Installation and Removal Decrease Leading Edge Exposure by 87% OSHA Compliant Versatile and Reusable Use Perimeter Protection Posts During Construction: At Building Perimeter

More information

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available. Concrete inserts offered in this section are designed to provide a pre-set support point in concrete ceilings, walls, and floors. A range of inserts with varying design loads are available. Materials Carbon

More information

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification

More information

Design No. P921 April 16, Restrained Assembly Rating 1, 1-1/2 or 2 Hr (See Items 4, 6, 7 and 9) Unrestrained Assembly Rating 0 Hr (See Item 7)

Design No. P921 April 16, Restrained Assembly Rating 1, 1-1/2 or 2 Hr (See Items 4, 6, 7 and 9) Unrestrained Assembly Rating 0 Hr (See Item 7) Design No. P921 April 16, 2003 Restrained Assembly Rating 1, 1-1/2 or 2 Hr (See Items 4, 6, 7 and 9) Unrestrained Assembly Rating 0 Hr (See Item 7) Unrestrained Beam Rating 1, 1-1/2 or 2 Hr (See Items

More information

SECTION FACILITY SANITARY SEWERS

SECTION FACILITY SANITARY SEWERS SECTION 22 13 13 FACILITY SANITARY SEWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board. 1.2 RELATED WORK A. Installation of steel framing members for walls, partitions,

More information

ROOF DRAINS TABLE OF CONTENTS

ROOF DRAINS TABLE OF CONTENTS Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF

More information

SECTION HVAC DUCTS AND CASINGS

SECTION HVAC DUCTS AND CASINGS SECTION 23 31 00 HVAC DUCTS AND CASINGS PART 1 -GENERAL 1.1 SUMMARY A. Section includes metal ductwork, nonmetallic ductwork, casing and plenums, buried ductwork, kitchen hood ductwork, duct cleaning.

More information

Technical Data Sheet. Astro HPE Sealant. UIC of product-type: AFHPE

Technical Data Sheet. Astro HPE Sealant. UIC of product-type: AFHPE Technical Data Sheet Astro HPE Sealant UIC of product-type: AFHPE Revision 2 - July 2016 Astroflame (Fireseals) LTD : Unit 8, I.O Centre Stephenson Road : Segensworth : Fareham : PO15 5RU Tel - 01329 844500

More information

40'-0" PIPE SUPPORT (TYP.) (SEE DWG. NO. SK-2 OR DWG. NO. SK-4)

40'-0 PIPE SUPPORT (TYP.) (SEE DWG. NO. SK-2 OR DWG. NO. SK-4) SK-1 STANDARD LENGTH 4.301 40'-0" A 6" 2'-0" 9'-0" 9'-0" 9'-0" 9'-0" 2'-0" A 3" OF EXPOSED AT EACH END OF PIPE. PIPE SUPPORT (TYP.) (SEE DWG. NO. SK-2 OR DWG. NO. SK-4) EXPOSED PIPE MINIMUM GAUGE AND THICKNESS

More information

SECTION Domestic Water Piping. A. American National Standards Institute (ANSI)/American Water Works Association (AWWA)

SECTION Domestic Water Piping. A. American National Standards Institute (ANSI)/American Water Works Association (AWWA) SECTION 22 11 16 Domestic Water Piping PART 1 GENERAL 1.1 SECTION INCLUDES A. PEX a tubing and fittings for domestic water piping. 1.2 REFERENCES A. American National Standards Institute (ANSI)/American

More information

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. SECTION 260529 - HANGERS AND SUPPORTS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. 1.2

More information

Floor Insulation Underlayment Section Sound Control Matting

Floor Insulation Underlayment Section Sound Control Matting Floor Insulation Underlayment Section 09618 Sound Control Matting Part I General 1.1 Summary A. Section includes a sound control material for achieving an STC and IIC rating in excess of 50 to meet building

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 1316 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

Evolution Series. 8" Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning.

Evolution Series. 8 Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning. Wiremold electrical systems conform to and should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities. All electrical

More information

Protecting Penetrations in Fire Rated Construction

Protecting Penetrations in Fire Rated Construction Protecting Penetrations in Fire Rated Construction NY State Fire Marshals and Inspectors Conference September 7 th Bruce E. Johnson UL Codes and Advisory Services UL and the UL logo are Trademarks of UL

More information

Patent No. 9,045,900 Technical Glass Products Architectural Specification Manual

Patent No. 9,045,900 Technical Glass Products Architectural Specification Manual Technical Glass Products Architectural Specification Manual 800.426.0279 fireglass.com FIREFRAMES ALUMINUM SERIES INTERIOR APPLICATION ONLY Fireframes Aluminum Series combined with Pilkington Pyrostop

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 4 6587 (562) 699 0543 www.icc es.org ESR 3152 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00

More information

SPECIFICATION GUIDELINES FOR THE USE OF CRYOGEL Z ON COLD PIPING AND EQUIPMENT

SPECIFICATION GUIDELINES FOR THE USE OF CRYOGEL Z ON COLD PIPING AND EQUIPMENT SPECIFICATION GUIDELINES FOR THE USE OF CRYOGEL Z ON COLD PIPING AND EQUIPMENT Page 1 of 15 Ver. 3-0 March 2010 TABLE OF CONTENTS 1. Scope... 3 2. General System Requirements... 3 3. Installation Details...

More information

SECTION G RELIEF VENTS A-0

SECTION G RELIEF VENTS A-0 SECTION G A-0 TABLE OF CONTENTS Thaler Or Equal RV-1A/-RV-1C Relief Vent RV-2A/-RV-2C Relief Vent RV-3A/-RV-3C One Way Relief Vent Relief Vent Specification G-0 G-1 G-2 G-3 G-4, G-5, G-6 WHAT IT TAKES

More information

ENKASONIC FLOOR UNDERLAYMENT 9110

ENKASONIC FLOOR UNDERLAYMENT 9110 ENKASONIC FLOOR UNDERLAYMENT 9110 GS1197 Section 13080 SECTION 09618 SOUND CONTROL MATTING Part I General 1.1 Summary A. Section includes a sound control material for achieving an STC and IIC rating in

More information

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague, Part E Pack Dear Colleague, This is the first 2017 update to the Part E Robust Details Handbook. In this update pack, we have focussed on clarifying the situation on incorporating underfloor heating (UFH)

More information

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION SECTION 230713 DUCT INSULATION PART 1 GENERAL 1.1 SUMMARY A. Related Sections: 1. 233113 Ductwork and Accessories 1.2 REFERENCES A. American Society for Testing and Materials (ASTM): 1. E84-96a Test Method

More information

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer... SECTION DIRECTORY General Information Introduction... V250-ID-886 Installation Accessories and Applications... V250-ID-886 Typical Sealant Placement Details... V250-ID-887 Fin Installation Details Wood

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3435 Reissued 07/2017 This report is subject to renewal 07/2018. DIVISION: 07 00

More information

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008 SECTION 092900 - GYPSUM BOARD 1.1 SUMMARY A. This Section includes the following: 1. Interior gypsum board. 2. Tile backing panels. B. Related Sections include the following: 1. Division 06 Section "Rough

More information

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation Recommended Design Considerations and Guide Specifications For Commercial Building Insulation Date of Issue: October 1, 2004 Recommended Design Considerations and Guide Specifications For Commercial Building

More information

Electrical Metallic Tubing (EMT) Fittings

Electrical Metallic Tubing (EMT) Fittings Suggested Specifications for Electrical Metallic Tubing (EMT) Fittings Series 2 Insulated EMT Connector (Raintight) (Compression Type) Series 20 EMT Coupling (Raintight) (Compression Type) Series 0 Pipe

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT SECTION 220529 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Steel pipe hangers and supports. 2. Metal framing systems. 3. Thermal-hanger shield inserts. 4. Fastener systems.

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 4073 Issued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2218 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 07 00

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING SECTION 221316 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following soil and waste, sanitary drainage and vent piping inside the building: 1. Pipe, tube,

More information

CONSULTANT PROCEDURES & DESIGN GUIDELINES Electrical Manholes and Handholes UNIVERSITY OF MISSOURI

CONSULTANT PROCEDURES & DESIGN GUIDELINES Electrical Manholes and Handholes UNIVERSITY OF MISSOURI GENERAL: The scope of this document is to provide instruction for the installation of concrete electric manholes. DESIGN GUIDELINES: 1. Materials for Manhole 1.1. Cast-in-Place or Pre-Cast concrete may

More information

SECTION PIPING INSULATION

SECTION PIPING INSULATION SECTION 23 07 19 PIPING INSULATION PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Piping insulation for refrigerant piping within building envelope. 2. Furnishing and installation of insulation.

More information

ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS

ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS 701-1 DESCRIPTION 701-1.1 This item shall consist of the construction of pipe culverts, and storm drains, removal of existing storm pipes, connections to existing

More information

SECTION UNIT MASONRY SYSTEM

SECTION UNIT MASONRY SYSTEM SECTION 04320 UNIT MASONRY SYSTEM PART 1 GENERAL 1.01 SECTION INCLUDES A. Concrete masonry and face brick units. B. Reinforcement, anchorage, and accessories. 1.03 SUBMITTALS A. Submit product data under

More information

Trench Duct Class Catalog 5230CT9601R10/08

Trench Duct Class Catalog 5230CT9601R10/08 5230CT9601R10/08 2009 Class 5230 CONTENTS Application.................................................5 Unassembled Trench Duct Components.........................6 Factory Assembled Trench Duct..............................11

More information

Stainless Steel Aeration Equipment Specification

Stainless Steel Aeration Equipment Specification Section 15 Stainless Steel Aeration Equipment Specification Part 1 - General 1.01 Description A. Scope of Work 1. Furnish, install and test aeration system including air mains, drop pipes, valves, expansion

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIRESTOPPING REPORT HOLDER: PASSIVE FIRE PROTECTION PARTNERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIRESTOPPING REPORT HOLDER: PASSIVE FIRE PROTECTION PARTNERS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2996 Reissued 12/2017 This report is subject to renewal 12/2019. DIVISION: 07 00

More information

BXUV.U465. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

BXUV.U465. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263 Page Bottom BXUV.U465 Fire Resistance Ratings - ANSI/UL 263 Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements

More information

PRECAST RECTANGULAR CHAMBERS

PRECAST RECTANGULAR CHAMBERS STANDARD MODELS GENERAL ROUGH SKETCH Available for: Sewer manhole, valve chamber, trouser manhole, and pumping station. Ø60-Ø762 ADJUSTMENT RING 7-00-2-0 20-2 30-60 RING 200-30 60-60 000-220 9ø 6 FLAT

More information

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows: SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.

More information

Code Compliance Research Report CCRR-0194

Code Compliance Research Report CCRR-0194 Code Compliance Research Report CCRR-0194 Issued: 09-16-2013 Renewal Due: 09-16-2018 Revised: 10-12-2017 DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES Section: 06 05 23 Wood, Plastic, and Composite

More information

TOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations

TOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations TOLCO Fire Protection Support Systems Pipe Hangers Supports Seismic Bracing UL Listed FM Approved for Fire Sprinkler Installations Revision 12/06/2007 Catalog Forward This catalog has been created with

More information

Design & Construction Standards, Revised January

Design & Construction Standards, Revised January PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

SECTION BASIC ELECTRICAL MATERIALS AND METHODS SECTION 26 05 05 BASIC ELECTRICAL MATERIALS PART 1 - GENERAL 1.1 SUMMARY A. Section includes the limited scope construction materials and methods for application with electrical installations as follows:

More information

Installation Instructions

Installation Instructions InnoFlue Single Wall, Flex, Concentric Vent System The installation instructions should be kept with the appliance for maintenance. Examine all components for possible shipping damage prior to installation.

More information

CANADA SPECIFIC FIRESTOPPING REQUIREMENTS

CANADA SPECIFIC FIRESTOPPING REQUIREMENTS APPENDIX I FCIA MOP CANADA AMENDMENT CANADA SPECIFIC FIRESTOPPING REQUIREMENTS FCIA s Manual of Practice is written to reflect worldwide practices of firestopping and compartmentation Each country will

More information

University of Delaware

University of Delaware University Contact: Energy & Engineering Group (302) 831-1744 SECTION 23 07 00_ HVAC INSULATION PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Piping system insulation. 2. Equipment insulation. 3.

More information

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No. SECTION 092900 GYPSUM BOARD PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Jean Vaillancourt Fire Protection Specialist Hilti (Canada) Corp.

Jean Vaillancourt Fire Protection Specialist Hilti (Canada) Corp. Cable Management Firestop Jean Vaillancourt Fire Protection Specialist Hilti (Canada) Corp. FIRESTOPPING KNOWLEDGE FOR BETTER SPECIFICATION AND DESIGN OF FIRE-RATED CONSTRUCTION Presentation Topics and

More information

BioPrism Solid Surface

BioPrism Solid Surface Please read all instructions before installing products. STORAGE & HANDLING: Check for damage that may have occurred during transit. Keep receptor flat on pallet, as it was shipped, until ready to install.

More information

Fig Beam Clamp Retaining Strap (B-Line B3367)

Fig Beam Clamp Retaining Strap (B-Line B3367) Fig. 69 - Beam Clamp Retaining Strap (B-Line B3367) Size Range: 3 /8"-16 thru 3 /4"-10 rod 4 (101.6mm) thru 16 (406.4mm) lengths Note: longer lengths are available consult factory Material: Pre-Galvanized

More information

CERTIFICATE OF APPROVAL No CF 563 SIDERISE INSULATION LIMITED

CERTIFICATE OF APPROVAL No CF 563 SIDERISE INSULATION LIMITED CERTIFICATE OF APPROVAL No CF 563 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Forge Industrial Estate,

More information

SECTION BUILDING INSULATION. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION BUILDING INSULATION. Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 07210 BUILDING INSULATION Display hidden notes to specifier. (Don't know how? Click Here) A. Perimeter Fire Containment Systems. B. Building Insulation for Thermal

More information

SECTION FACILITY STORM DRAINAGE

SECTION FACILITY STORM DRAINAGE PART 1 - GENERAL 1.1 DESCRIPTION SECTION 22 14 00 Storm drainage systems, including piping and all necessary accessories as designated in this section. 1.2 RELATED WORK A. Penetrations in rated enclosures:

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION CHAPTER 26 PLASTIC SECTION BC 2601 GENERAL 2601.1 Scope. These provisions shall govern the materials, design, application, construction and installation of foam plastic, foam plastic insulation, plastic

More information

Section BUILDINGS, SHELTERS, ENCLOSURES

Section BUILDINGS, SHELTERS, ENCLOSURES Section 13121 BUILDINGS, SHELTERS, ENCLOSURES Part 1 GENERAL 1.1 SECTION INCLUDES 1.2 A. Pre-engineered buildings. B. Pre-engineered shelters. C. Pre-engineered enclosures. D. Electrical wiring and devices

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1504 Reissued 03/2017 This report is subject to renewal 03/2018. DIVISION: 07 00

More information

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION MANUFACTURED ROOF EXPANSION JOINTS SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3089 Reissued 07/2016 This report is subject to renewal 07/2018. DIVISION: 07 00

More information