THE BRITE THING TO DO

Size: px
Start display at page:

Download "THE BRITE THING TO DO"

Transcription

1 REDUCING ENERGY CONSUMPTION IMPROVING AIR QUALITY THE BRITE THING TO DO BRITE-n-EZ Enhanced Coating Application Process on Black EPDM Roof Membrane

2 BRITE-n-EZ EPDM Application Instructions CLEANING Remove all debris from roof surface. Vacuum or use a leaf blower to remove surface dust. All surfaces to receive BRITE-n-EZ Enhanced Coating or Flashing Compound shall be thoroughly cleaned using a high-pressure spray washer (with a minimum of 3,000 psi), clean water and a strong cleaning detergent metered through the washers pick up tube. Starting at the highest point on the roof, power wash toward the nearest drain or gutter removing all loose debris, dirt and other buildup. The entire surface should then be rinsed with clean water and allowed to dry. POWER WASH WITH DETERGENT EPDM ROOF TO BE COATED TWELVE YEAR OLD EPDM LOOSE CARBON BLACK REMAINS AFTER POWER WASHING If the cleaned EPDM surface does not have a jet black appearance a second cleaning step may be necessary. Fill a hand held pressure sprayer with a commercial grade cleaner that has a high PH. Mist the membrane surface with the cleaner. Allow this cleaner to stand for a minimum of twenty minutes but no longer than eight hours. Then immediately rinse down the slope toward the roof drainage points using a hose to avoid over spray of the cleaner onto other surfaces. Allow the prepared surface to completely dry. Use of Water Tight Technologies proprietary BRITEn-EZ Coating Primer in this coating system provides superior coating adhesion over other acrylic coating products on the market. Even after diligent power washing of this 12 year old EPDM roof, a surface layer of carbon black still remains. The loss of carbon black is detrimental to adhesion of a coating applied to an unprimed EPDM roof surface.

3 ROOF REPAIR AND INSPECTION Upon the completion of the initial surface preparation, inspect all seams and flashings on penetrations, curbs, transition points, vents, drains, scuppers, etc. for water proof integrity. As a general rule, for these details to maintain their water proof integrity it is recommended the details be flashed with BRITE-n-EZ Flashing Compound and Reinforced Flashing Fabric. EPDM repairs may also be done with EPDM cover strip with TRANSITION SEAM IN NEED OF REPAIR Follow EPDM manufacturers application instructions. tape or EPDM uncured cover strip with tape. The seam or flashing detail should be cleaned as indicated above and then primed with BRITE-n- EZ Coating Primer. Primer is roller applied to an area several inches beyond where the flashing is to be applied. TRANSITION SEAM REPAIR SEAM REPAIR The flashing is done in a three course method. With a roller or trowel, apply the flashing compound in a six inch wide application. Lay in the BRITE-n-EZ Flashing Fabric while the compound is wet. Apply a second layer of compound. Continue until there are three courses of BRITE-n-EZ Flashing Fabric with a top coat of BRITE-n-EZ Flashing Compound. Coverage rate for the three course method of flashing is 20 to 25 lineal feet per gallon. Apply when temperatures are above 40 degrees F for the next 48 hours. Avoid fish mouths and wrinkles in the flashing fabric. Flashing will not fully cure for 48 hours. Flashing may be coated after 24 hours. Take care not to walk on the flashing before it is fully cured (48 hours). THREE COURSE FLASHING COMPOUND AND FABRIC

4 PRIME EPDM MEMBRANE Open and stir BRITE-n-EZ Coating Primer with a wooden paddle. Do not use an electric drill or any other tool that might generate a spark. Insure adequate ventilation when priming the roof. Be certain windows and ventilation ducts to the building are closed so that vapors are not taken into the building. Read product label for additional application and precaution instructions. PRIMER BINDS LOOSE CARBON BLACK AND ENHANCES COATING ADHESION Apply BRITE-n-EZ Coating Primer to the cleaned EPDM membrane surface with a solvent resistant paint roller. Avoid primer contact with skin. It is not necessary to apply primer to the flashings done in the roof repairs discussed previously. BRITE-n-EZ Coating Primer must be applied with a solvent resistant paint roller to an area 4 to 5 feet in width and for the length of the roof that can easily be reached with a long handled paint roller. Do not walk on the primed area. If you walk on the primer after it is dry, but before the first application of coating, the tacky primer will stick to your shoes and it may be partially removed from the membrane. PRIME WALL FLASHING Spraying the primer is not allowed. By roller applying the primer, one is assured of adequate wetting of the EPDM surface and binding of any loose carbon black on the surface that was not washed away when power washed. Let the primer dry. Drying time is quite quick depending on sun light and humidity. On a sunny day, primer applied to EPDM membrane surface may dry in as little as 15 minutes. Primer appears shiny when applied and dull black when dry. AS THE PRIMER IS TACKY WHEN DRY, ONE SHOULD PRIME AND APPLY THE FIRST LAYER OF COATING IN THE SAME DAY TO AVOID DUST AND DEW COLLECTING ON THE PRIMER OVER NIGHT. NEVER APPLY PRIMER OR COATING TO A ROOF SURFACE THAT IS WET FROM RAIN OR DEW. PRIME SURFACE IN 5 FOOT STRIPS Coverage rate for primer is 200 to 250 square feet per gallon. BRITE-n-EZ Coating Primer is flammable. Avoid sparks and open flames. Be certain that nearby windows are closed and there are no intake air vents or fans open to the roof area.

5 APPLY FIRST LAYER OF COATING Test the coating primer with your finger. The primer should be tacky but not stringy to a dry finger touch. After BRITE-n-EZ Coating Primer has dried, roller apply the first coat of BRITE-n-EZ Enhanced Coating to the 4 to 5 foot width by length area of roof that was primed taking care not to walk on the primer. It is important to note that very small air bubbles may have been created in the priming process. Roller applying the first coat bursts these bubbles and insures good adhesion. IMPORTANT: DO NOT SPRAY APPLY THE FIRST LAYER OF COATING. It is important to stir each pail of BRITE-n-EZ Enhanced Coating with a blade paddle powered by an electric drill. TESTING PRIMER Start the coating application from the same side of the roof where the primer was first applied to insure primer has adequately dried. Apply coating to within six inches of the primed edge of the membrane without applying coating to the unprimed area. Apply BRITE-n-EZ Enhanced Coating at a rate of 100 square feet per gallon with a paint roller. Apply an even coat with the roller in one direction. MICRO BUBBLES IN PRIMER Continue to apply BRITE-n-EZ Enhanced Coating and Primer to subsequent 4 to 5 foot strips of the roof until the first coat has been completed. Typically a two man crew is most efficient. By the time the first person has finished a 4 to 5 foot wide strip applying BRITE-n-EZ Coating Primer, the primer will have dried and a second person can begin applying the BRITE-n-EZ Enhanced Coating, starting from the side of the roof where the primer was first applied. While the person moves across the roof applying BRITE-n-EZ Enhanced Coating to the area previously primed, the other person can already begin applying BRITEn-EZ Coating Primer to the next 4 to 5 foot strip of membrane surface. Allow the first BRITE-n-EZ Enhanced Coating application to fully cure (usually 24 to 48 hours) with no chance of rain while curing. DO NOT APPLY BRITE-n-EZ Enhanced Coating WHEN EPDM MEMBRANE SURFACE TEMPERATURE IS LOWER THAN 40 DEGREES OR HIGHER THAN 120 DEGREES FAHRENHEIT. ROLLER APPLY COATING TO WITHIN 6 INCHES OF PRIMERS EDGE PRIMING AND COATING

6 APPLY SECOND LAYER OF COATING After the first coat has fully cured (usually 24 hours), apply a second coat of BRITE-n-EZ Enhanced Coating at a rate of 100 square feet per gallon. It is recommended that the second coat be applied with an airless sprayer for superior appearance that hides the first coat roller marks. Sprayer application also provides the greatest productivity. On smaller jobs one may use a paint roller. Use a cross hatch method of roller applying the coating in cross direction from that of the first coating application. As the roof surface is not tacky once the first application of BRITE-n- EZ Enhanced Coating has been applied, one is not restricted to applying the coating in 4 foot SPRAY APPLY BRITE-n-EZ TM FOR UNIFORMITY strips across the roof. For added esthetics, protection and reflectivity, a third coat of BRITE-n- EZ Enhanced Coating may be spray applied. Minimum Recommended Spray Equipment for BRITE-n-EZ Enhanced Coating SPRAY EQUIPMENT BRITE-n-EZ TM ; EASY TO APPLY, HIGHLY REFLECTIVE GRACO AIRLESS SPRAYER Max. Pressure 4900 psi Flow Rate 3.9 Gallons per minute Tip Size to Horse Power 16 HP minimum SPEEFLO HYDRA M-4000 Max. Pressure 4000 psi Flow Rate 3.3 Gallons per minute Tip Size to Horse Power 16 HP minimum Hoses Use 3/4" high pressure hose (double wire braid) to connect to the spray pump. Use 1/2" high pressure hose and connect one end to the 3/4" hose, and connect the other end to the spray gun. The spray gun should be an industrial gun or a mastic gun. It is important to realize that hose sizes are directly related to distance. The list above assumes that the maximum distance from pump is 300' with each hose having a length of 150'. ADDITIONAL INFORMATION When applied at a rate of 1 gallon per square, the theoretical wet thickness is 15 mils and the dry film thickness is 7 mils. If the goal is to have a water

7 proofing membrane rather than a white reflective coating, additional coats may be applied. Store BRITE-n-EZ Enhanced Coating in unopened containers at 40 to 80 degrees Fahrenheit. BRITE-n-EZ Enhanced Coating clean-up is with water. BRITE-n-EZ Coating Primer clean up is with toluene or white gas. Limitations include: Not shipping or storing BRITE-n-EZ Enhanced Coating below 32 degrees Fahrenheit; BRITE-n-EZ Enhanced Coating is not recommended in ponding water situations (insure positive drainage) BRITE-n-EZ Enhanced Coating should not be applied when weather conditions do not allow for proper drying and curing. BRITE-n-EZ Enhanced Coating is ready to use. Do not thin. If necessary, stir the material slowly to ensure uniformity. Do not mix at high speed. BRITE-n-EZ TM IS EASY TO APPLY BRITE-n-EZ Flashing Compound: Based on a 6 wide three course application the coverage will be approximately lineal feet per gallon. BRITE-n-EZ Coating Primer: Coverage rate for primer is 200 to 250 square feet per gallon. BRITE-n-EZ Enhanced Coating: Coverage rate is 100 sq. ft. per gallon for each coat. A two coat application is required as a reflective coating. Three or more coats may be required as a water proofing membrane or one may use BRITE-n-EZ Plus, which is higher in solids and is most efficient to apply when one is looking for a water proofing membrane rather than a reflective coating. Product Specifications: available at COVERAGE RATES This document is intended as a general guideline. If the actual project conditions are such as to be outside the scope of the normal waterproofing and coating practices that are referenced BRITE-n-EZ TM, ANYONE CAN DO IT in these instructions, steps should be taken to insure the restoration remains in compliance with nationally recognized waterproofing practices such as those found in the National Roofing Contractors Association Manual.

8 WATER TIGHT TECHNOLOGIES MINDFUL OF THE CONTRACTOR'S EVER CHANGING NEEDS YESTERDAY BLACK ROOFS WITH MINIMAL INSULATION DOMINATED COMMERCIAL AND RESIDENTIAL LOW SLOPE ROOFING. TODAY TO REDUCE ENERGY COSTS AND SAVE OUR ENVIRONMENT, BUILDING OWNERS ARE ASKING CONTRACTORS TO APPLY... Member Water Tight Technologies was green before green became COOL. WATER TIGHT TECHNOLOGIES P.O. Box 899 Payson Arizona Copyright Water Tight Technologies and BRITE-n-EZ TM are trademarks of Water Tight Technologies. All Rights Reserved.

DURA 500 THERMOPLASTIC FLAT ROOF COATING SYSTEM BY SUPERIOR POLYMERS INC.

DURA 500 THERMOPLASTIC FLAT ROOF COATING SYSTEM BY SUPERIOR POLYMERS INC. SPECIFICATION GUIDELINE FOR SMOOTH ROOF SUBSTRATES INCLUDING MODIFIED BITUMEN, SMOOTH ASPHALT, EPDM, TPO, AND PLYWOOD. Part 1 General Information For the purpose of clarification in this document, the

More information

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING (TO RESTORE EPDM MEMBRANES) PART 1 GENERAL 1.01 DESCRIPTION A. The scope of this design guideline is to describe the installation of the ALDOCOAT Silicone reflective

More information

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION STUC-O-FLEX RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION 09 97 23 PART 1-GENERAL 1.00 SCOPE: Manufacturer's specifications containing the requirements necessary

More information

TOPCOAT System Specifications Corrugated Transite Panels

TOPCOAT System Specifications Corrugated Transite Panels TOPCOAT System Specifications Corrugated Transite Panels Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com TOPCOAT System Specifications Corrugated Transite

More information

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification Product Data Sheet Pondseal Waterproofing Membrane for Ponds and Water Features Description Pondseal is a polyurethane / acrylic co-polymer, water based coating which when fully cured, forms an impervious,

More information

Product Information CHEMGLAZE B 9942 A/B. Coating for Casting Pits. Easy Application Chemglaze B 9942 A/B will bond to damp and wet surfaces.

Product Information CHEMGLAZE B 9942 A/B. Coating for Casting Pits. Easy Application Chemglaze B 9942 A/B will bond to damp and wet surfaces. Product Information Chemical Products Division CHEMGLAZE B 9942 A/B Coating for Casting Pits. FEATURES BENEFITS. Easy Application Chemglaze B 9942 A/B will bond to damp and wet surfaces. Will build to

More information

Instruction Guide APPLICATION OF CIM TO CONCRETE

Instruction Guide APPLICATION OF CIM TO CONCRETE 23 Elm St., Peterborough, NH 03458 Tel: (800) 543-3458 (603) 924-9481 Fax: (603) 924-9482 Web site: Instruction Guide APPLICATION OF CIM TO CONCRETE 1.0 DESCRIPTION This guide covers the installation of

More information

TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets

TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com TOPCOAT Restoration Specifications

More information

GEOGARD LO Base Coat / GEOGARD Finish Coat

GEOGARD LO Base Coat / GEOGARD Finish Coat GENERAL GUIDELINE SPECIFICATION LO Base Coat / Finish Coat WATERPROOFING SYSTEM FOR MODIFIED BITUMEN ROOFS PART 1 General 1.01 General A. This document is intended to provide only general guidelines regarding

More information

FLUID APPLIED ROOFING - HYPALON ROOF RESTORATION

FLUID APPLIED ROOFING - HYPALON ROOF RESTORATION The enclosed specifications are designed to summarize the activities and responsibilities of all the principal parties to a roofing project. Oftentimes, the guide specification will function as the primary

More information

BEP Blue Barrier Installation and Application Guide

BEP Blue Barrier Installation and Application Guide BEP Blue Barrier Installation and Application Guide BEP Blue Barrier is a system of seamless fluid applied products designed to protect the building envelope. Approved assemblies and applications listed

More information

Guideline Specification ACRYMAX ARS-1-C Reinforced Composite Elastomeric Membrane System for Concrete Roofs Fluid-Applied Roofing

Guideline Specification ACRYMAX ARS-1-C Reinforced Composite Elastomeric Membrane System for Concrete Roofs Fluid-Applied Roofing 221 Brooke Street Media, PA 19063 610-566-7470 Fax 610-891-0834 Website www.acrymax.com e-mail info@acrymax.com This document is intended to provide guidelines for the proper specification and application

More information

ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION

ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION PART 1 - GENERAL 1.01 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions,

More information

TOPCOAT Restoration Specifications Structural Concrete

TOPCOAT Restoration Specifications Structural Concrete TOPCOAT Restoration Specifications Structural Concrete Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com TOPCOAT Restoration Specifications Structural Concrete

More information

AVM System 500. Aussie Membrane 500

AVM System 500. Aussie Membrane 500 Generic Spec TECH DATA SHEET Sections - 071000 / 071400 / 071416 ICC ESR-2503 L.A. RR#: 25550 Heavy Duty Below Grade Bituminous Waterproofing Membrane Sections 071000 / 071400 / 071416 Fluid Applied Waterproofing

More information

Blue Barrier Liquid Wrap 2300

Blue Barrier Liquid Wrap 2300 Tools/Materials Needed 5 gal pail of PolyWall Blue Barrier Liquid Wrap 2300 10.1 oz Caulking Tube of Poly Wall Blue Barrier 2200 Joint Filler Caulking gun 9 to 11-inch Hot Dog Style Roller handle and Mini

More information

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION STUC-O-FLEX - ELASTOMERIC ACRYLIC FINISH APPLICATION TO PORTLAND CEMENT PLASTER / CONCRETE RENDER MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION 09220-09 24 00 PART 1-GENERAL SCOPE: Manufacturer's

More information

FireShield System Specifications Mineral Surface Cap, Mop Granule and Torch Granule APP Cap Sheets

FireShield System Specifications Mineral Surface Cap, Mop Granule and Torch Granule APP Cap Sheets FireShield System Specifications Mineral Surface Cap, Mop Granule and Torch Granule APP Cap Sheets Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com FireShield

More information

ITEM 458 WATERPROOFING FOR STRUCTURES

ITEM 458 WATERPROOFING FOR STRUCTURES ITEM 458 WATERPROOFING FOR STRUCTURES 458.1. Description. This Item shall govern for the furnishing and placing of waterproofing on concrete and steel bridge decks of railroad structures and on other structures

More information

BEP Blue Barrier Installation and Application Guide

BEP Blue Barrier Installation and Application Guide BEP Blue Barrier Installation and Application Guide BEP Blue Barrier is a system of seamless fluid applied products designed to protect the building envelope. Approved assemblies and applications listed

More information

General Applications Before applying, mix the pre-measured catalyst* into Liquid Roof by following label directions.

General Applications Before applying, mix the pre-measured catalyst* into Liquid Roof by following label directions. General Applications Before applying, mix the pre-measured catalyst* into Liquid Roof by following label directions. Surface Preparation: Surface to be coated should be clean, dry and structurally sound.

More information

GE SCM3500 High Solids Silicone Roof Coating

GE SCM3500 High Solids Silicone Roof Coating GE SCM3500 High Solids Silicone Roof Coating Installation Guide Specification For GRANULATED or SMOOTH MODIFIED BITUMEN / BUR (20 Year Warranty) Warranty PART 1 GENERAL 1.01 SUMMARY A. This specification

More information

ROOF SUBSTRATE PREP MANUAL

ROOF SUBSTRATE PREP MANUAL ROOF SUBSTRATE PREP MANUAL ALDOCOAT Liquid Applied Roof Restoration Systems AFTER BEFORE JULY 2016 1604 N. Main St. Kannapolis, NC 28081 (800) 474-6019 www.aldoproducts.com ROOF SUBSTRATE PREPARATION Preparation

More information

Sample Specification

Sample Specification Sample Specification Section 02760 Paving Specialties StencilCoat Commercial Asphalt and Concrete Surfacing System 1.0 GENERAL 1.1 Summary The StencilCoat Commercial Asphalt Surfacing System is a 100%

More information

System Specifications

System Specifications 100% Silicone Roof Coating System for Existing, Aged, Smooth and Granulated Modified Bitumen Membrane Systems TABLE OF CONTENTS PART 1 GENERAL Page 1.1 Scope of Work... 1 1.2 Related Sections... 1 1.3

More information

TUFF-TAC TM BRIDGE MEMBRANE INSTALLATION GUIDE

TUFF-TAC TM BRIDGE MEMBRANE INSTALLATION GUIDE 5 pages TUFF-TAC TM BRIDGE MEMBRANE INSTALLATION GUIDE The following will describe the proper procedure to use when installing Tuff-Tac TM bridge deck membrane. The guide will cover recommended tools to

More information

PRODUCT DATA SHEET SARNACOL 2121

PRODUCT DATA SHEET SARNACOL 2121 PRODUCT DATA SHEET SARNACOL 2121 Sarnacol 2121 Membrane Adhesive is a water-based dispersion adhesive used for Sarnafil or Sikaplan Adhered roofing systems. Sarnacol 2121 is formulated for adhering membranes

More information

TEX COTE 600 TEXTURED COATING MASONRY PROTECTIVE COATING

TEX COTE 600 TEXTURED COATING MASONRY PROTECTIVE COATING SECTION 09960 - TEXTURED COATINGS Coating System Submittals Guide Specification TEX COTE 600 TEXTURED COATING MASONRY PROTECTIVE COATING (SPLIT FACE OR SAND FINISH BLOCK) 1. TEX COTE 600, Textured Coating

More information

SECTION mil thickness COLD FLUID-APPLIED WATERPROOFING

SECTION mil thickness COLD FLUID-APPLIED WATERPROOFING SECTION 07 14 16 CCW-MIRASEAL @ 120 mil thickness COLD FLUID-APPLIED WATERPROOFING PART 1 - GENERAL 1.1 SECTION INCLUDES: Installation of waterproofing membrane on surfaces indicated on drawings, consisting

More information

Acry-Tek 4200 / SPF Recoat System

Acry-Tek 4200 / SPF Recoat System WARRANTY SPECIFICATION Acry-Tek 4200 / SPF Recoat System MASTER GUIDE SPECIFICATIONS This MASTER GUIDE-SPEC is a brief outline of Coating & Foam Solutions, LLC.(CFS) roofing requirements and is intended

More information

Section COATING RESTORATION

Section COATING RESTORATION Sto Corp. 3800 Camp Creek Parkway Building 1400, Suite 120 Atlanta, GA 30331 Tel: 404-346-3666 Toll Free: 1-800-221-2397 Fax: 404-346-3119 www.stocorp.com 80658R StoColor Texture - Coarse Textured Acrylic-Based,

More information

B. Protection of concrete mosaic, metals, stone, and other adjacent materials during all other work activities in related sections, below.

B. Protection of concrete mosaic, metals, stone, and other adjacent materials during all other work activities in related sections, below. GUIDELINE FOR WRITING SPECIFICATIONS WHEN USING CSP Paint Strippers Select Relevant Section Division 09900 Paints and Coatings Part 1 GENERAL 1.1 RELATED DOCUMENTS A. Work of this section shall be governed

More information

Eclipse ECL-G-2 Clear High Solids Polyurethane Topcoat

Eclipse ECL-G-2 Clear High Solids Polyurethane Topcoat Technical Data Sheet Product Group Polyurethane topcoat Characteristics Product Information ECL-G-2 is a high solids, long life clear coat formulated for use with Eclipse base coat and special effect colors

More information

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS CHECKLIST PRIOR TO THE INSTALLATION OF BACKSTOP NT - SMOOTH AND TEXTURE Project Conditions Maximum storage

More information

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy SELECTION & SPECIFICATION DATA Generic Type Description Features Color Finish Primer Cycloaliphatic Amine Epoxy Highly chemical resistant epoxy mastic coating with exceptionally versatile uses in all industrial

More information

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: METACRYLICS

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: METACRYLICS 0 Most Widely Accepted and Trusted ICC ES Legacy Report ICC ES 000 (800) 6587 (56) 699 05 www.icc es.org ER 785 Reissued 09/017 This report is subject to renewal 09/0. DIVISION: 07 00 00THERMAL AND MOISTURE

More information

ARCHITECTURAL SPECIFICATIONS LOOSE LAID & BALLAST SYSTEM

ARCHITECTURAL SPECIFICATIONS LOOSE LAID & BALLAST SYSTEM 57460 Dewitt Street Elkhart, Indiana 46517-1078 Phone (574) 293-9096 Fax (574) 294-3450 800-628-2957 Web site: www.roofingproductsint.com ARCHITECTURAL SPECIFICATIONS LOOSE LAID & BALLAST SYSTEM B1.00

More information

FIVE STAR PRODUCTS, INC. (800)

FIVE STAR PRODUCTS, INC.  (800) FIVE STAR PRODUCTS, INC. www.fivestarproducts.com (800) 243-2206 Page 1 of 11 DESIGN-A-SPEC GUIDELINES FIVE STAR RS ANCHOR GEL CONTENTS PART A - GENERAL CONDITIONS PART B - MATERIAL SPECIFICATIONS PART

More information

Technical Service. INSTALLATION INSTRUCTIONS FOR TARAFLEX SPORT PRODUCTS over Gypsum base Products. This document refers to the following products:

Technical Service. INSTALLATION INSTRUCTIONS FOR TARAFLEX SPORT PRODUCTS over Gypsum base Products. This document refers to the following products: INSTALLATION INSTRUCTIONS FOR TARAFLEX SPORT PRODUCTS over Gypsum base Products This document refers to the following products: Product Width Width Ft. Installation direction Seams treatment Taraflex Surface

More information

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 STUC-O-FLEX PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 PART 1 - GENERAL 1.01 DESCRIPTION Provide all labor, materials and equipment necessary

More information

8245 Remmet Ave Canoga Park, CA (888) Installation Instructions - AVM System 700 Under Tile Waterproofing and Anti-Fracture Membrane

8245 Remmet Ave Canoga Park, CA (888) Installation Instructions - AVM System 700 Under Tile Waterproofing and Anti-Fracture Membrane 8245 Remmet Ave Canoga Park, CA. 91304 (888) 414-1041 Division 7-Moisture Protection Page 1 Table of Contents General... 2 Approvals... 2 Applicator... 2 Product Delivery, Storage and Handling... 2 Limitations...

More information

Refer to Substrates & Surface Preparation.

Refer to Substrates & Surface Preparation. SELECTION & SPECIFICATION DATA Generic Type Description Features Color Finish Primer Dry Film Thickness Aliphatic Acrylic Polyurethane Thin film, high gloss finish with exceptional weathering performance

More information

SAMPLE SPECIFICATION

SAMPLE SPECIFICATION SAMPLE SPECIFICATION Section 02760 Paving Specialties STREETCOAT Epoxy Modified Traffic Coating System IDEAL FOR VEHICULAR TRAFFIC, BIKE LANES AND COATING STAMPED ASPHALT SURFACES 1.0 GENERAL 1.1 Summary

More information

Corlar 2.1 PR-P High Solids Productive Epoxy Primer

Corlar 2.1 PR-P High Solids Productive Epoxy Primer Corlar 2.1 PR-P High Solids Productive Epoxy Primer GENERAL DESCRIPTION A high solids, two component, VOC conforming (2.1 lbs./gal.) Low HAPS productive primer based on Axalta modified polyamide epoxy

More information

Application Specification:

Application Specification: Application Specification: GW-15-UBU-HD April 2014 Supersedes 5/13 PART 1 - GENERAL 1.1 SUMMARY Division 07 18 16: GACOFLEX POLYURETHANE ELASTOMERIC COATING SYSTEM FOR VEHICULAR TRAFFIC DECKS AND RAMPS

More information

SECTION SELF-ADHERING SHEET WATERPROOFING

SECTION SELF-ADHERING SHEET WATERPROOFING SECTION 07 13 26 SELF-ADHERING SHEET WATERPROOFING This guide specification has been prepared by Polyguard Products Inc., in printed and electronic media, as an aid to specifiers in preparing written construction

More information

SECTION CO-POLYMER ELASTOMERIC COOL-ROOF COATING

SECTION CO-POLYMER ELASTOMERIC COOL-ROOF COATING SECTION 076000 - CO-POLYMER ELASTOMERIC COOL- PART 1 - GENERAL 1.1 SUMMARY OF WORK A. Contractor is to supply the necessary labor, materials, and equipment to coat existing roof system (approximately 390

More information

Corlar 2.1 PR-P High Solids Productive Epoxy Primer For Use With FG-040, FG-041 or FG-042 Activators

Corlar 2.1 PR-P High Solids Productive Epoxy Primer For Use With FG-040, FG-041 or FG-042 Activators Corlar 2.1 PR-P High Solids Productive Epoxy Primer For Use With FG-040, FG-041 or FG-042 Activators GENERAL DESCRIPTION A high solids, two component, high build, VOC conforming (2.1 lbs./gal.) Low HAPS

More information

***********************************************************************************

*********************************************************************************** AQUAFIN-2K/M Two-Component Cement-based Acrylic-based Waterproofing GUIDE AQUAFIN, Inc. SPECIFICATION PART 1 - GENERAL 1.1 SECTION INCLUDES SECTION 07 16 14 ACRYLIC MODIFIED (FLEXIBLE) CEMENTITIOUS WATERPROOFING

More information

ARDEX GUIDE SPECIFICATION ARDEX CD Concrete Dressing and ARDEX CD FINE Concrete Dressing Polymer-Modified, Portland Cement-Based, Resurfacing Compound

ARDEX GUIDE SPECIFICATION ARDEX CD Concrete Dressing and ARDEX CD FINE Concrete Dressing Polymer-Modified, Portland Cement-Based, Resurfacing Compound ARDEX GUIDE SPECIFICATION ARDEX CD Concrete Dressing and ARDEX CD FINE Concrete Dressing Polymer-Modified, Portland Cement-Based, Resurfacing Compound SECTION 03 01 30 MAINTENANCE OF CAST-IN-PLACE CONCRETE

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2045 Reissued 01/2017 This report is subject to renewal 01/2019. DIVISION: 07 00

More information

White, a range of ready-mixed colours, and colours from the Dulux Colour System

White, a range of ready-mixed colours, and colours from the Dulux Colour System TECHNICAL DATA SHEET Version 2 2016 SEPTEMBER THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS PRODUCT DESCRIPTION High quality interior or exterior matt finish PRODUCT USES Recommended for exterior and

More information

Application Specification:

Application Specification: Application Specification: GacoFireStop2 F5001 (Half-Pound) March 2014 Supersedes 7/11 Division: 07 21 19 GUIDE SPECIFICATION GacoFireStop2 F5001 INSULATION PART 1 GENERAL This guide specification discusses

More information

DULUX INTERIOR LUXURIOUS SILK TECHNICAL DATA SHEET Version SEPTEMBER THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS

DULUX INTERIOR LUXURIOUS SILK TECHNICAL DATA SHEET Version SEPTEMBER THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS TECHNICAL DATA SHEET Version 1 2016 SEPTEMBER THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS PRODUCT DESCRIPTION A low odour premium quality interior mid sheen finish with supreme stain resistance. PRODUCT

More information

Rust Bullet Home and Farm FAQ s

Rust Bullet Home and Farm FAQ s Rust Bullet Home and Farm FAQ s 1. Will Rust Bullet Protect My Galvanized Metal Roof? Yes. Rust Bullet is the ideal coating for protecting sheet metal buildings and roofs; it not only provides protection

More information

REV:6-30/09/30. Liquid Rubber Timber Specification

REV:6-30/09/30. Liquid Rubber Timber Specification REV:6-30/09/30 Liquid Rubber Contents: 1. Preparation 2. Application 3. Additional Information 4. Things To Be Aware Of When Applying To Timber 1. Preparation: Prior to commencing ensure the decking is

More information

Installation Instructions

Installation Instructions Installation Instructions I. GENERAL INFORMATION KEY CHIP-100 FLOORING is a decorative resin flooring system consisting of clear, 100% solids epoxy resin and colored vinyl chips. KEY CHIP-100 FLOORING

More information

Elastomeric Protected Membrane Roofing Fluid-Applied Protected Membrane Roofing. Restoration Coating System (RCS) over Cap Sheet

Elastomeric Protected Membrane Roofing Fluid-Applied Protected Membrane Roofing. Restoration Coating System (RCS) over Cap Sheet 07 55 53 Elastomeric Protected Membrane Roofing 07 55 56 Fluid-Applied Protected Membrane Roofing Restoration Coating System (RCS) over Cap Sheet PART 1 - GENERAL 1.1 SUMMARY A. This specification covers

More information

Aliphatic Acrylic-Polyester Polyurethane

Aliphatic Acrylic-Polyester Polyurethane SELECTION & SPECIFICATION DATA Generic Type Description Features Color Finish Primer Dry Film Thickness Aliphatic Acrylic-Polyester Polyurethane High build, low sheen finish that has excellent resistance

More information

REFLECTIT. Reflectit Application Instructions Spray and Roller DS % Acrylic Coating Providing a Pearlescent Appearance

REFLECTIT. Reflectit Application Instructions Spray and Roller DS % Acrylic Coating Providing a Pearlescent Appearance REFLECTIT 100% Acrylic Coating Providing a Pearlescent Appearance Reflectit Application Instructions Spray and Roller Tools Required for Application of Reflectit Spray Application 1. Stainless Steel Trowel

More information

HYDRAULIC GATE SEALS. Industrial Rubber Supply (1995) Ltd.

HYDRAULIC GATE SEALS. Industrial Rubber Supply (1995) Ltd. Industrial Rubber Supply (1995) Ltd. Manufacturers of Quality Industrial Products 55 Dunlop Avenue, Winnipeg, Manitoba, Canada R2X 2V2 Phone (204) 694-4444 - Fax (204) 632-6767 - www.indrub.com ISO 9001:2000

More information

NXT SUBSTRATE PREPARATION AND PRIMER GUIDE TDS 230N

NXT SUBSTRATE PREPARATION AND PRIMER GUIDE TDS 230N NXT SUBSTRATE PREPARATION AND PRIMER GUIDE TDS 230N Substrate preparation is the most important factor to successful NXT self-leveling underlayment (SLU) and NXT Vapor Reduction Coating installations.

More information

FEATURES AND BENEFITS

FEATURES AND BENEFITS Product Information Technical Data Sheet - August 2017 DiamondCoat Slate & Stone Sealer - Satin Clear, tough, low sheen treatment for slate and natural stone. DESCRIPTION Crommelin DiamondCoat Slate &

More information

AQUATITE. Also designed as: Crack/gap filler for masonry and unglazed ceramics Sealants against leaks Repairer for roof cracks and gutters

AQUATITE. Also designed as: Crack/gap filler for masonry and unglazed ceramics Sealants against leaks Repairer for roof cracks and gutters AQUATITE Revision Date: september 2007 Description Bondall AquaTite is a grey, brushable, waterproofing coating that forms a flexible yet tough, seamless membrane. This single pack product exceeds the

More information

Paint to Protect TM International Fireproof Technology, Inc Von Karman Ave. Irvine, CA 92614

Paint to Protect TM International Fireproof Technology, Inc Von Karman Ave. Irvine, CA 92614 Paint to Protect TM International Fireproof Technology, Inc. 17528 Von Karman Ave. Irvine, CA 92614 Product Name: DC 315 Fireproof Paint for Foam Name of Company: International Fireproof Technology, Inc.

More information

Maximum Rust Protection!

Maximum Rust Protection! ZERO-RUST Zero Rust is a direct-to-metal, phenolic modified alkyd rust and corrosion control coating, which controls rust and corrosion by putting down an impermeable barrier at the steel level. Its dielectric

More information

MAKE ROOFS LAST LONGER

MAKE ROOFS LAST LONGER MAKE ROOFS LAST LONGER Roof Coatings & Roof Repair Single-Ply Metal Asphalt HIGHEST PERFORMING SYSTEMS. LOWEST APPLIED COST. METAL ROOF RESTORATION Metal Restoration Quick Guide Acrylic Polyurethane High

More information

TOPCOAT Product Catalog

TOPCOAT Product Catalog TOPCOAT Product Catalog (TOPGN235) Updated: 7/14 gaf.com TOPCOAT L I Q U I D-APPL IED R O O F I N G gaf.com Energy-Saving Liquid-Applied Roofing Solutions! FEWER COATS FEWER GALLONS FEWER LABOR HOURS BIGGER

More information

BTM BT2K 600. Areas of Use

BTM BT2K 600. Areas of Use BTM BT2K 600 Bitumento BT2K 600 is a solvent-free, two-component, elastic, water-based, fiber reinforced, rubber and cement based bitumen waterproofing material. Areas of Use As water and moisture tight

More information

NFCA 400 Field Quality Assurance Procedure for Application of Mastic and Thin-Film Intumescent Fire Resistive Coatings

NFCA 400 Field Quality Assurance Procedure for Application of Mastic and Thin-Film Intumescent Fire Resistive Coatings NFCA 400 Field Quality Assurance Procedure for Application of Mastic and Thin-Film Intumescent Fire Resistive Coatings 1 Scope The application of mastic and thin-film intumescent fire resistive coatings

More information

DULUX WEATHERGUARD FINE TEXTURED

DULUX WEATHERGUARD FINE TEXTURED TECHNICAL DATA SHEET Version 1 2016 JULY THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS PRODUCT DESCRIPTION A tough, durable exterior coating with Maxiflex that provides lasting elasticity to cover hairline

More information

Good roofing practice has

Good roofing practice has Good roofing practice has always been to tear off an existing roof to the deck and replace it with new material, but that is beginning to change. The time has come in which tearing off an older roof may

More information

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong) Approved 402;2522 1,2 2522 zinc epoxy ^(ValidationDate) 1 Product description This is a two component polyamide cured zinc rich epoxy coating. It is a high zinc dust containing product. It conforms to

More information

SP-100 Equipment Wash SP-110 Tool Cleaner SP-120 Internal Storage Lubricant

SP-100 Equipment Wash SP-110 Tool Cleaner SP-120 Internal Storage Lubricant DESCRIPTION: SP-9888 Pipe Lining is based on the latest Zero VOC Novolac Technology. The product cures to a highly cross-linked coating with excellent chemical, solvent and water immersion resistance.

More information

Corlar LV PR 178 Series Epoxy Primer

Corlar LV PR 178 Series Epoxy Primer Corlar LV PR 178 Series Epoxy Primer GENERAL DESCRIPTION A two-component very low VOC corrosion-resistant epoxy primer designed to be extremely tough and durable. When properly activated, the combined

More information

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate Colphene BSW Training and Application Guide Colphene BSW Waterproofing Membrane. 1. Prepare substrate Substrate must be structurally sound. Surface must be free of voids, spalled areas, loose aggregate,

More information

Part 1 - General. Spec Component Sikadur 32 Hi-Mod. DIVISION 3 -CONCRETE Section Cast-in-Place Concrete Bonding Agents for Concrete

Part 1 - General. Spec Component Sikadur 32 Hi-Mod. DIVISION 3 -CONCRETE Section Cast-in-Place Concrete Bonding Agents for Concrete Spec Component 042-0101 Sikadur 32 Hi-Mod DIVISION 3 -CONCRETE Section 03300 Cast-in-Place Concrete Bonding Agents for Concrete Part 1 - General 1.01 Summary A. This specification describes the bonding

More information

To ensure warranty eligibility, each job must be approved by American WeatherStar before it begins.

To ensure warranty eligibility, each job must be approved by American WeatherStar before it begins. SPRAY POLURETHANE FOAM & COATINGover metal roof deck SPF To ensure warranty eligibility, each job must be approved by American WeatherStar before it begins. PART 1 GENERAL 1.01 DESCRIPTION A. The intention

More information

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong Approved 20920;16620 1 20920 epoxy ^(ValidationDate) 1 Product description This is a two component amine cured epoxy coating. It is a fast drying, zinc phosphate pigmented, high solids, high build product.

More information

A Design Review of Waterproofing Codes

A Design Review of Waterproofing Codes A Design Review of Waterproofing Codes Section 1807 of Chapter 18 of the International Building Code addresses waterproofing under the section title of Dampproofing and Waterproofing. The section defines

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3392 Reissued 06/2017 This report is subject to renewal 06/2018. DIVISION: 07 00

More information

3MTM FireDamTM Intumescent Coating WB Installation Manual. Thinner is. Better

3MTM FireDamTM Intumescent Coating WB Installation Manual. Thinner is. Better 0808-3086E 3M FD Intumescent Coating WB 1000 - INSTALLATION MANUAL:Layout 1 9/30/08 2:32 PM Page 1 3MTM FireDamTM Intumescent Coating WB 1000 Installation Manual Thinner is Better 3 1 Index 1. Product

More information

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 2080;2081 1 2080 epoxy VValidationDate). 1 Product description This is a two component polyamide cured epoxy coating. It is a high solids, high build product. Designed as a mid coat in systems for new

More information

SCOPE OF WORK PROJECT IDENTIFICATION

SCOPE OF WORK PROJECT IDENTIFICATION PROJECT IDENTIFICATION SCOPE OF WORK PROJECT NAME: Wickenburg High School PROJECT: Gym Roof 1 SITE ADDRESS: 1090 S. Vulture Mine Rd. Wickenburg AZ 85390 City State ZIP Code SCOPE OF WORK SUMMARY: 1. Extend

More information

Low cost because floor renovation can be completed the same day

Low cost because floor renovation can be completed the same day ARDEX SD-L ARDEX SD-L Technical Information & Installation Instructions Product Info Formatted Specifications MSDS Find in this page: Technical Information Installation Instructions Technical Information

More information

3910 E. McKinney Denton, TX P.O. Box Dallas, TX EZ WALL CONCENTRATE, INC

3910 E. McKinney Denton, TX P.O. Box Dallas, TX EZ WALL CONCENTRATE, INC EZ Spread Coarse Sand Description EZ Spread is the perfect material for small projects and repairs. This factory prepared blend of portland cement proprietary additives, and sand. EZ Spread is designed

More information

Freedom One-Piece Barrier Free Showers Installation Instructions

Freedom One-Piece Barrier Free Showers Installation Instructions Tools & Materials you might need for proper installation Materials: 2-1 gallon buckets of solid wood flooring adhesive or 100% silicone adhesive (non-shrink) 20-1.25 wood screws 1-5 gallon bucket (to mix

More information

DIVISION 9 FINISHES Section Floor Finishes

DIVISION 9 FINISHES Section Floor Finishes Spec Component: SC-032-0807 Supersedes: SS-032-0601 DIVISION 9 FINISHES Section 09600 Floor Finishes Part 1 - General 1.01 Summary A. This specification describes the application of a waterproofing, slip

More information

SECTION CONCRETE AND MASONRY COATINGS

SECTION CONCRETE AND MASONRY COATINGS 80658 StoColor Texture - Coarse Textured Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction SECTION 099723 CONCRETE AND MASONRY COATINGS Sto Corp.

More information

Ash Brook Golf Course Scotch Plains, New Jersey

Ash Brook Golf Course Scotch Plains, New Jersey SECTION 033543 - POLISHED CONCRETE FINISHING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Rust-Oleum Industrial Brands Specification

Rust-Oleum Industrial Brands Specification Rust-Oleum Industrial Brands Specification Coating Specification for Rust-Oleum Virtual Solutions Coating Solution 2 A solvent based coating system High Performance 9100/9800 System DTM Epoxy Mastic/DTM

More information

GenFlex EZ TPO Peel & Stick SA (HW) APPLICATION GUIDE

GenFlex EZ TPO Peel & Stick SA (HW) APPLICATION GUIDE GenFlex EZ TPO Peel & Stick SA (HW) APPLICATION GUIDE I. MEMBRANE APPLICATION... 2 A. MEMBRANE... 2 II. MEMBRANE ATTACHMENT... 2 III. SEAMING... 3 A. SEAMING FOR GENFLEX EZ TPO PEEL & STICK SA (HW)...

More information

FLUID APPLIED WATERPROOFING

FLUID APPLIED WATERPROOFING SECTION 07120 FLUID APPLIED WATERPROOFING PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 03300 - Cast-In-Place Concrete. 2. 09200 - Metal Studs, Metal Lath, Suspension Ceilings, Plaster, and Stucco.

More information

Dow Corning AllGuard Silicone Elastomeric Coating. Application and Maintenance Guide

Dow Corning AllGuard Silicone Elastomeric Coating. Application and Maintenance Guide Dow Corning AllGuard Silicone Elastomeric Coating Application and Maintenance Guide Contents This document is intended to provide installation and field testing instructions for Dow Corning AllGuard Silicone

More information

POLYMER CONCRETE 100 EPOXY POLYMER CONCRETE DILUTE ACIDS RESISTANCE

POLYMER CONCRETE 100 EPOXY POLYMER CONCRETE DILUTE ACIDS RESISTANCE RECOMMENDED APPLICATIONS Polymer Concrete 100 is a three-component, epoxy polymer concrete used for the construction of chemical resistant floors, pads, curbing, trenches and sumps. Polymer Concrete 100

More information

SECTION COMMON WORK RESULTS FOR CONCRETE SSPECIALTY COATINGS

SECTION COMMON WORK RESULTS FOR CONCRETE SSPECIALTY COATINGS SECTION 03 05 00 COMMON WORK RESULTS FOR CONCRETE 09 97 00 SSPECIALTY COATINGS Weld Crete ************************************************************************************************************************

More information

SPECIFICATIONS FOR RUBAROC SAFETYDECK (FOR PLAYGROUND SURFACES)

SPECIFICATIONS FOR RUBAROC SAFETYDECK (FOR PLAYGROUND SURFACES) SPECIFICATIONS FOR RUBAROC SAFETYDECK (FOR PLAYGROUND SURFACES) PART I GENERAL 1.1 WORK INCLUDED: Work in this section includes furnishing all labour, materials, equipment, and services required to install

More information

Rubber Roofing Pocket Application Guide

Rubber Roofing Pocket Application Guide Rubber Roofing Pocket Application Guide Table of Contents Page 2.......................... General Information Page 2........................ Cautions and Warnings Page 3.......................... Recommended

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PEDESTRIAN TRAFFIC COATINGS REPORT HOLDER: WESTCOAT

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PEDESTRIAN TRAFFIC COATINGS REPORT HOLDER: WESTCOAT 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2201 Reissued 07/2016 This report is subject to renewal 07/2018. DIVISION: 07 00

More information

Vulkem EWS with PUMA Technology (Heavy Duty) APPLICATION INSTRUCTIONS

Vulkem EWS with PUMA Technology (Heavy Duty) APPLICATION INSTRUCTIONS Vulkem EWS with PUMA Technology (Heavy Duty) APPLICATION INSTRUCTIONS 1. Purpose 1.1 The purpose of this document is to establish uniform procedures for applying the Vulkem Extreme Wearing System (EWS).

More information