1 TML Home Inspectors, Inc. Ph. (630) Inspector: Jerry Zieleziecki License # xxxx Expiration Date: 11/30/2014 Date: Time: Property Address: Client: Phone: () RE agent: Phone: PURPOSE OF INSPECTION The purpose of the inspection is to determine, and prepare a written report of, the apparent condition of the readily accessible installed systems and components of the Premises existing at the time of the inspection. SCOPE OF INSPECTION The scope of the inspection and report is strictly limited to a visual inspection of the apparent condition of the readily accessible installed systems and components of the premises. The inspection will be performed in accordance with the Illinois Standards of Practice, 68 ILL. Admin. Code 1410, Sec The scope of the inspection is strictly limited to the system and components listed in the inspection report. OUTSIDE SCOPE OF THE INSPECTION Latent and concealed defects and deficiencies are excluded from the inspection. Any area which is not exposed to view, is concealed, or is inaccessible because of soil, walls, floors, carpets, ceilings, furnishings, or any other thing is not included in this inspection. The inspection does not include any destructive testing or dismantling. Client agrees to assume all the risk for all conditions which are concealed from view at the time of the inspection. This is not a home warranty, guarantee, or insurance policy or substitute for real estate transfer disclosures which may be required by law. The Client understands that the following systems and components, whether or not they are latent or concealed, and information about them are specifically excluded from and outside the scope of this inspection: Building code or zoning ordinance violations. Geological stability or soils condition. Structural stability or engineering analysis. Termites, pests or other wood destroying organisms. Asbestos, radon, formaldehyde, lead, water, or air quality, electromagnetic radiation or any environmental hazards. Building value appraisal or cost estimates. Condition of detached buildings. Pools or spas bodies and underground piping. Specific components noted as being excluded on the individual system inspection forms. Private water or private sewage systems. Saunas, steam baths, or fixtures and equipment. Radio-controlled devices, automatic gates, elevators, lifts, dumbwaiters, and thermostatic or time clock controls. Water softener/purifier systems or solar systems. Furnace heat exchangers, freestanding appliances, security alarms or personal property. Adequacy and/or efficiency of any system or component. Prediction of life expectancy of any item. (Some of the above items can be included in this inspection for additional fees check with your inspector). Your inspector is a home inspection generalist and is not acting as a licensed engineer or expert in any craft or trade. If your inspector recommends consulting other specialized experts, the client must do so at client s expense. TML Home Inspectors, Inc. tmlhomeinspectors@gmail.com (630) Page 1 of 18

2 Property address _ TABLE OF CONTENTS Page# Client & inspector information, purpose & scope, general limitation & exclusions Table of contents, general information Ground & exterior structures Exterior walls Roof & gutters Attic Garage Cooling system Heating system & chimney Interior, windows & doors Plumbing Electrical Appliances Foundation & structure Summary GENERAL INFORMATION Type of the building Foundation type/material Methods used to inspect the roof Methods used to inspect the attic Roof covering Roof structure Exterior wall structure Exterior wall covering Wall insulation Amperage and voltage rating of the service Breakers/Fuses Location of the panel Presence aluminum branch circuit wiring Wiring methods Smoke & CO detectors Heating type & system Fuel type Cooling system Water heater Main gas valve location Fireplaces Solid fuel burning appliances Chimneys Main water valve location Water supply pipes Drain/vent/sewer pipes TML Home Inspectors, Inc. Ranch Crawlspace/Concrete (poured concrete and concrete blocks) Entered roof Entered attic Asphalt shingles Rafters Wood frame Composite siding N/a (No access) 100/200 A, 110/240 V Home 100 A, Breakers 15/20/30 Amps Garage 200 A, Breakers 20/30/60 Amps Furnace room N/a Typical Smoke/CO Forced air/central Natural gas Central Gas/40 Gal. Gas meter/outside Yes No Masonry Furnace room (private water well) Copper/Galvanized steel PVC/Cast iron tmlhomeinspectors@gmail.com (630) Page 2 of 18

3 HOME INSPECTION REPORT Repair damaged driveway and walkway. Repair damaged deck and baluster. Repair damaged front concrete stairs. Repair/replace damaged shed. GROUND & EXTERIOR STRUCTURES Ground & exterior structures pictures Damaged walkway Damaged deck Damaged front concrete stairs EXTERIOR WALLS The siding is deteriorated and loose in some areas. Further deterioration can occur if not corrected. A qualified person should inspect the extent of the deterioration and repair or replace as needed. Exterior walls pictures Damaged siding TML Home Inspectors, Inc. tmlhomeinspectors@gmail.com (630) Page 3 of 18

4 Property address _ ROOF & GUTTERS The roof coverings (shingles) are considered to be in good condition. Caulking all exposed nails is recommended to prevent water penetration. Roof structure: 1. Wavy roof was noted. Wavy roof may be caused by damaged roof decking and/or cracked rafters (observed). A qualified, licensed roofing contractor should evaluate and repair as needed. 2. Repair cracked rafters. 3. Cut rafters need to be reinforced. 4. Repair damaged roof decking at the furnace chimney (caused by improper flashing). Replace damaged fascias and soffits. Install missing gutters and downspouts. Roof & gutters pictures Exposed nails Wavy roof Cracked rafters Cracked rafters TML Home Inspectors, Inc. tmlhomeinspectors@gmail.com (630) Page 4 of 18

5 Cut rafters need support Damaged roof decking Damaged fascia Damaged soddits and fascias ATTIC Insulation amount less than current standards. Attic needs more insulation. Insulation is compressed and needs to be refilled to prevent heat loss. Install missing soffit vents. The level of ventilation throughout the attic and all roof cavities should be improved. It is generally required that 1 square foot of free vent area be provided for every 150 square feet of ceiling area (soffits and upper vents). Proper ventilation will help to keep the home cooler during warm weather and extend the life of the roofing materials. Proper ventilation will also help reduce the potential for heat build-up, condensation within the attic and mold grow. Found black mold growing on a surface of the roof sheathing. The cause of mold growth was poor ventilation due to the missing soffit vents. Correct. TML Home Inspectors, Inc. tmlhomeinspectors@gmail.com (630) Page 5 of 18

6 Attic pictures Attic needs more insulation Roof sheathing mold Roof sheathing mold GARAGE Roof covering (shingles) signs of weathering and aging noted. The roofing is near the end of its useful life. Expect to replace the roof soon. All flashings should be installed during re-roofing. Further guidance should be obtained by a licensed roofing contractor. Install missing gutters and downspouts. Replace damaged fascias and soffits. Replace damaged wood siding. Foundation walls and concrete slab not fully visible due to covering. Repair cracked foundation, masonry wall and concrete slab (common cracks). Repair cracked chimney. Repair cracked retaining wall at the garage door. (Safety hazard) Missing GFCI outlets were noted. The GFCI (Ground fault circuit interrupters) is designed to protect people from severe or fatal electric shocks. Because a GFCI detects ground faults, it can also prevent some electrical fires and reduce the severity of others by interrupting the flow of electric current. Install GFCI outlets. The exposed cables (Romex) need to be protected by rigid, metal conduit. All of the circuits in the electrical distribution panel are required to be properly labeled. TML Home Inspectors, Inc. tmlhomeinspectors@gmail.com (630) Page 6 of 18

7 Garage pictures Old roof Missing gutters and downspouts, damaged soffits and fascias Cracked foundation Missing GFCI, cable needs protection COOLING SYSTEM No major defects were observed in the visible/accessible portions of the cooling systems. HEATING SYSTEM & CHIMNEY Repair furnace blower (vibrations were noted). Install missing air filter. Attic: 1. Repair loose/open ducts. 2. The ducts need to be insulated to prevent heat loss (crawlspace & attic). TML Home Inspectors, Inc. (630) Page 7 of 18

8 Property address _ Chimneys: 1. Repair cracked concrete crowns and flues. 2. Install missing rain caps. 3. Install proper flashing (furnace chimney). 4. Replace corroded/loose fireplace chimney cleanout (at the exterior). Install missing smoke and CO detectors. The fireplace needs to be replaced (corroded fire box, missing damper were noted). The ducts require cleaning. Heating system & chimney pictures Attic loose duct, missing insulation Cracked flue, missing rain cap Improper chimney flashing Corroded fireplace INTERIOR, WINDOWS & DOORS Some areas and items at this property were obscured by furniture, stored items. This often includes but is not limited to walls, floors, windows, inside and under cabinets, under sinks, on counter tops, in closets, behind window coverings, under rugs or carpets, and under or behind furniture. Areas around the exterior, under the structure, in the garage and in the attic may also be obscured by storing items. The inspector in general does not move personal belongings, furnishings, carpets or appliances. When furnishings, stored items or debris are present, all areas or items that are obscured, concealed or not readily accessible are excluded from the inspection. The client should be aware that when furnishings, stored items or debris are eventually moved, damage or problems that were not noted during the inspection may be found. Wall insulation and R-value is not verified, conditions inside the wall cannot be judged. Flaws and cracks were noted in various locations of the interior. The cracking does not appear to be the result of a structural failure. The repairs will be necessary in some areas. Furnace room the vinyl floor tiles may contain asbestos fibers (recommend further tests). In the past, asbestos fibers were added during the production of flooring materials to strengthen the flooring and to increase its durability. Vinyl floor tiles that contain asbestos, when intact and in good condition, is generally considered no friable and is not hazardous. Removal is often not the best option for reducing asbestos exposure. Often, it is best to seal and leave asbestos containing material in place because disturbing it may release airborne microscopic fibers that could be inhaled. Further evaluation and correction by a licensed professional recommended. TML Home Inspectors, Inc. tmlhomeinspectors@gmail.com (630) Page 8 of 18

9 The bathroom with a shower did not have an exhaust fan installed. Moisture accumulation will occur and may damage the structure. Even if the bathroom has a window that opens, it likely does not provide adequate ventilation, especially during cold weather when the window is closed. A qualified contractor should install exhaust fans as per standard building practices where missing in bathrooms with showers. Flooring is uneven and shows signs of settlement or sagging (minor) in the floor joists/beam. Recommend evaluation by a licensed contractor and repairs if necessary. Windows: 1. Repair/replace damaged screens. 2. Replace cracked storm window pane (bedroom). 3. The windows are old, single pane and have no insulated properties. These windows should be replaced with double pane gas filled type to conserve energy. 4. Repair/replace damaged exterior trims. Interior, windows and doors pictures Furnace room the vinyl floor tiles may contain asbestos fibers (recommend further tests Old, single pane windows Damaged windows trims PLUMBING Interior supply water piping future replacement of galvanized water pipe can be anticipated as galvanized piping has a tendency to either rust through or close-up internally as a result of corrosion; thereby, restricting water flow. Leaks are common in aging systems of this kind. Attic install proper plumbing vent plug. Bathroom install missing/damaged drain stoppers (sinks and bathtub). Crawlspace the supply water pipes need to be insulated to prevent freezing in the winter months. Pressure tank install insulation to prevent tank sweating. Water well pump the pump comes on and off every few seconds when faucets are open (short cycling). Short cycling is typically caused by: 1. A water logged pressure tank. 2. Controls that are either set wrong or are ineffective. 3. Drastically oversized pump. Contact a qualified licensed plumber to review and repair or replace as necessary. TML Home Inspectors, Inc. tmlhomeinspectors@gmail.com (630) Page 9 of 18

10 Plumbing pictures Improper plumbing vent plug The pump comes on and off every few seconds, missing tank insulation ELECTRICAL The overhead service conductors had inadequate clearance from tree branches at the time of the inspection. This condition should be corrected by a qualified electrical contractor to avoid abrasion, damage to the wires and fire. The live cables at the home roof needs protection. Service cables between garage and shed observed cables hanging too low over the yard. The service cables should be 10 feet above a walking surface. Correct as necessary. Shed: 1. Install missing GFCIs. 2. The service cables need protection. 3. The overhead service conductors had inadequate clearance from siding and wall. This condition should be corrected by a qualified electrical contractor to avoid abrasion, damage to the wires and fire. Crawlspaces: 1. Replace improper BX conduit (wet location). 2. Replace improper sump pump wiring (extension cord was noted) (Safety hazard) The GFCI did not test properly at the kitchen. Repair or replace. (Safety hazard) Two-prong (ungrounded) receptacles were noted. Two-prong receptacles are considered unsafe by today's standards, and limit the ability to use appliances that require a ground in these rooms. This is a safety hazard for both fire and shock. Correct. Bathroom secure loose outlet. Secure loose switch box at the furnace. Pressure tank closet: 1. Install missing pressure switch relay cover. 2. The cables need to be protected by metal conduit. Correct. Attic: 1. (Safety hazard) Cover plates on the junction boxes were missing. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. A qualified person should repair as necessary. 2. The cables need to be protected by metal conduit. Correct. Distribution panel: 1. Recommend labeling the circuit breakers in the main electrical panel as required. 2. Observe double tapping breaker at the panel. Those breakers do not appear to be the type that allows for two conductors (the risk of a poor connection is greater with double taps). Correct. 3. Old, cloth insulated wire were noted (one of the biggest problems with cloth wiring is that it becomes weak and falls off of the wires that it is supposed to protect). All cloth-insulated wiring systems should be upgraded to protect from fire danger. TML Home Inspectors, Inc. tmlhomeinspectors@gmail.com (630) Page 10 of 18

11 Property address _ Electrical pictures The overhead service conductors had inadequate clearance from tree branches Unprotected (live) wires Cables hanging too low over the yard Shed cables inadequate clearance from siding and wall Cable need protection (shed) Missing GFCI (shed) Attic cables need protection, open junction boxes TML Home Inspectors, Inc. tmlhomeinspectors@gmail.com (630) Page 11 of 18

12 Relay switch missiong cover, cable needs protection Double tapping breaker at the panel Old, cloth insulated wires Recommend labeling the circuit breakers in the main electrical panel as required Crawlspace sump pump improper wiring Install missing kitchen vent. APPLIANCES FOUNDATION, DRAINAGE & STRUCTURE Foundation walls and crawlspace floors not fully visible due to covering and limited access (crawlspace viewed from access door only). Repair cracked concrete blocks at the main support beam. Repair/replace main beam support (concrete blocks, wood) to prevent sagging. TML Home Inspectors, Inc. (630) Page 12 of 18

13 Crawlspace under the family room: 1. Repair/replace faulty sump pump (water ponding was noted). 2. Replace improper discharge pipe and pit, install backflow valve. 3. Install proper drainage system to prevent water accumulation. Crawlspaces: 1. Install proper drain tiles, sump pumps and discharge pipes. 2. Evidence of prior and present water intrusion was found in one or more sections of the crawlspace. Accumulated water is a condition conducive for wood destroying insects and organisms and should not be present in the crawlspace. Contact a qualified contractor who specializes in drainage issues to evaluate, install and repair as necessary. Typical repairs for preventing water from accumulating in the crawlspace include: - Repairing, installing or improving rain run-off systems (gutters, downspouts and extensions or drain lines). - Improving perimeter grading. - Repairing, installing or improving underground perimeter drains and sump pump(s). 3. The soil was not spread evenly on the floor. Correct as necessary. 4. Crawlspace floor the vapor barrier (plastic) is missing. An adequate vapor barrier will create a dry air space between the damp soil and the framing, which will limit the amount of moisture that is able to rise into the framing (dampness in the crawl space area creates decay and deterioration of framing members). This also reduces the possibility of future moisture damage. The preferred material for use as a vapor barrier over the soil in the crawl space is six mil., or thicker, black polyethylene. The vapor barrier should cover the dirt from footing to footing and have a 6" overlap at the seams. 5. Missing/obstructed crawl space vents were noted. This can result in high levels of moisture in the crawl space and is a condition conducive for wood-destroying organisms. One square foot of vent area should be installed for 150 square feet of crawl space. Vents should be evenly distributed and within a few feet of corners to promote air circulation. Recommend that a qualified contractor install or improve venting per standard building practices. 6. Crawlspace ceiling install insulation to prevent heat loss. Foundation, drainage & structure pictures Missing vapor barrtier and ceiling insulation Crawlspace floor water ponding, missing drains and sump pump The soil was not spread evenly on the floor, moisture TML Home Inspectors, Inc. tmlhomeinspectors@gmail.com (630) Page 13 of 18

14 Cracked foundation wall (at the beam) Faulty/improper sump pump, pit & drain Missing vapor barrier, moisture Repair/replace main beam support (concrete blocks, wood) to prevent sagging TML Home Inspectors, Inc. (630) Page 14 of 18

15 HOME INSPECTION SUMMARY REPORT (no pictures) This items or component warrants additional attention, evaluate, repair, replace or monitoring. Repair damaged driveway and walkway. Repair damaged deck and baluster. Repair damaged front concrete stairs. Repair/replace damaged shed. GROUND & EXTERIOR STRUCTURES EXTERIOR WALLS The siding is deteriorated and loose in some areas. Further deterioration can occur if not corrected. A qualified person should inspect the extent of the deterioration and repair or replace as needed. ROOF & GUTTERS Caulking all exposed nails is recommended to prevent water penetration. Roof structure: 1. Wavy roof was noted. Wavy roof may be caused by damaged roof decking and/or cracked rafters (observed). A qualified, licensed roofing contractor should evaluate and repair as needed. 2. Repair cracked rafters. 3. Cut rafters need to be reinforced. 4. Repair damaged roof decking at the furnace chimney (caused by improper flashing). Replace damaged fascias and soffits. Install missing gutters and downspouts. ATTIC Insulation amount less than current standards. Attic needs more insulation. Insulation is compressed and needs to be refilled to prevent heat loss. Install missing soffit vents. Found black mold growing on a surface of the roof sheathing. The cause of mold growth was poor ventilation due to the missing soffit vents. Correct. GARAGE Roof covering (shingles) signs of weathering and aging noted. The roofing is near the end of its useful life. Expect to replace the roof soon. All flashings should be installed during re-roofing. Further guidance should be obtained by a licensed roofing contractor. Install missing gutters and downspouts. Replace damaged fascias and soffits. Replace damaged wood siding. Foundation walls and concrete slab not fully visible due to covering. Repair cracked foundation, masonry wall and concrete slab (common cracks). Repair cracked chimney. Repair cracked retaining wall at the garage door. (Safety hazard) Install missing GFCI outlets. The exposed cables (Romex) need to be protected by rigid, metal conduit. All of the circuits in the electrical distribution panel are required to be properly labeled. TML Home Inspectors, Inc. tmlhomeinspectors@gmail.com (630) Page 15 of 18

16 HEATING SYSTEM & CHIMNEY Repair furnace blower (vibrations were noted). Install missing air filter. Attic: 1. Repair loose/open ducts. 2. The ducts need to be insulated to prevent heat loss (crawlspace & attic). Chimneys: 1. Repair cracked concrete crowns and flues. 2. Install missing rain caps. 3. Install proper flashing (furnace chimney). 4. Replace corroded/loose fireplace chimney cleanout (at the exterior). Install missing smoke and CO detectors. The fireplace needs to be replaced (corroded fire box, missing damper were noted). The ducts require cleaning. INTERIOR, WINDOWS & DOORS Flaws and cracks were noted in various locations of the interior. The cracking does not appear to be the result of a structural failure. The repairs will be necessary in some areas. Furnace room the vinyl floor tiles may contain asbestos fibers (recommend further tests). Further evaluation and correction by a licensed professional recommended. Bathroom install missing exhaust fan and vent. Flooring is uneven and shows signs of settlement or sagging (minor) in the floor joists/beam. Recommend evaluation by a licensed contractor and repairs if necessary. Windows: 1. Repair/replace damaged screens. 2. Replace cracked storm window pane (bedroom). 3. The windows are old, single pane and have no insulated properties. These windows should be replaced with double pane gas filled type to conserve energy. 4. Repair/replace damaged exterior trims. PLUMBING Interior supply water piping future replacement of galvanized water pipe can be anticipated as galvanized piping has a tendency to either rust through or close-up internally as a result of corrosion; thereby, restricting water flow. Leaks are common in aging systems of this kind. Attic install proper plumbing vent plug. Bathroom install missing/damaged drain stoppers (sinks and bathtub). Crawlspace the supply water pipes need to be insulated to prevent freezing in the winter months. Pressure tank install insulation to prevent tank sweating. Water well pump the pump comes on and off every few seconds when faucets are open (short cycling). Short cycling is typically caused by: 1. A water logged pressure tank. 2. Controls that are either set wrong or are ineffective. 3. Drastically oversized pump. Contact a qualified licensed plumber to review and repair or replace as necessary. ELECTRICAL The overhead service conductors had inadequate clearance from tree branches at the time of the inspection. This condition should be corrected by a qualified electrical contractor to avoid abrasion, damage to the wires and fire. The live cables at the home roof needs protection. Service cables between garage and shed observed cables hanging too low over the yard. The service cables should be 10 feet above a walking surface. Correct as necessary. TML Home Inspectors, Inc. tmlhomeinspectors@gmail.com (630) Page 16 of 18

17 Shed: 1. Install missing GFCIs. 2. The service cables need protection. 3. The overhead service conductors had inadequate clearance from siding and wall. This condition should be corrected by a qualified electrical contractor to avoid abrasion, damage to the wires and fire. Crawlspaces: 1. Replace improper BX conduit (wet location). 2. Replace improper sump pump wiring (extension cord was noted) (Safety hazard) The GFCI did not test properly at the kitchen. Repair or replace. (Safety hazard) Replace ungrounded receptacles. Bathroom secure loose outlet. Secure loose switch box at the furnace. Pressure tank closet: 1. Install missing pressure switch relay cover. 2. The cables need to be protected by metal conduit. Correct. Attic: 1. (Safety hazard) Install missing cover plates on the junction boxes. 2. The cables need to be protected by metal conduit. Correct. Distribution panel: 1. Recommend labeling the circuit breakers in the main electrical panel as required. 2. Observe double tapping breaker at the panel. Those breakers do not appear to be the type that allows for two conductors (the risk of a poor connection is greater with double taps). Correct. 3. Old, cloth insulated wire were noted (one of the biggest problems with cloth wiring is that it becomes weak and falls off of the wires that it is supposed to protect). All cloth-insulated wiring systems should be upgraded to protect from fire danger. Install missing kitchen vent. APPLIANCES FOUNDATION, DRAINAGE & STRUCTURE Foundation walls and crawlspace floors not fully visible due to covering and limited access (crawlspace viewed from access door only). Repair cracked concrete blocks at the main support beam. Repair/replace main beam support (concrete blocks, wood) to prevent sagging. Crawlspace under the family room: 1. Repair/replace faulty sump pump (water ponding was noted). 2. Replace improper discharge pipe and pit, install backflow valve. 3. Install proper drainage system to prevent water accumulation. Crawlspaces: 1. Install proper drain tiles, sump pumps and discharge pipes. 2. Evidence of prior and present water intrusion was found in one or more sections of the crawlspace. Accumulated water is a condition conducive for wood destroying insects and organisms and should not be present in the crawlspace. Contact a qualified contractor who specializes in drainage issues to evaluate, install and repair as necessary. Typical repairs for preventing water from accumulating in the crawlspace include: - Repairing, installing or improving rain run-off systems (gutters, downspouts and extensions or drain lines). - Improving perimeter grading. - Repairing, installing or improving underground perimeter drains and sump pump(s). TML Home Inspectors, Inc. tmlhomeinspectors@gmail.com (630) Page 17 of 18

18 3. The soil was not spread evenly on the floor. Correct as necessary. 4. Crawlspace floor install missing vapor barrier. 5. Missing/obstructed crawl space vents were noted. This can result in high levels of moisture in the crawl space and is a condition conducive for wood-destroying organisms. One square foot of vent area should be installed for 150 square feet of crawl space. Vents should be evenly distributed and within a few feet of corners to promote air circulation. Recommend that a qualified contractor install or improve venting per standard building practices. 6. Crawlspace ceiling install insulation to prevent heat loss. TML Home Inspectors, Inc. Jerry Zieleziecki TML Home Inspectors, Inc. tmlhomeinspectors@gmail.com (630) Page 18 of 18

Inspection Report. 1 of 8

Inspection Report. 1 of 8 Inspection Report Dayvolt's Home Inspections L.L.C. Date&Time of Inspection: 5/9/17, 12:10 PM Inspector's Name: Dustin Dayvolt Building Address: Sample City: State: Zip Code: Type of property inspected:

More information

Page 3 of 12. Inspected Describe. Explained. Health & Safety. Maj. Def. Examiner Notes STRUCTURE N/A. Financial Impact. Impact.

Page 3 of 12. Inspected Describe. Explained. Health & Safety. Maj. Def. Examiner Notes STRUCTURE N/A. Financial Impact. Impact. STRUCTURE Foundations * Floor structure * Wall structure * Ceiling structure * Roof structure * Deficiencies in structure * Access Method d Under floor crawlspace/attic * Page 3 of 12 EXTERIOR Exterior

More information

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ 08014 856-467-3626--- FAX 856-467-9260 Application for Certificate of Occupancy for Change of Occupancy Pursuant to Chapter 119 of the Township

More information

InterNACHI Home Inspection Report Checklist

InterNACHI Home Inspection Report Checklist Client name: Inspected property address: Date and time of the inspection: Weather conditions: Approximate outdoor air temperature: People present at the time of the inspection: Estimated year built: Type

More information

Inspections Unlimited 12:38 August 20, 2013 Page 1 of 23 Sampleweb2013.pt6

Inspections Unlimited 12:38 August 20, 2013 Page 1 of 23 Sampleweb2013.pt6 12:38 August 20, 2013 Page 1 of 23 Table of Contents General Information 2 Component Ratings 3 Roof Surface 4 Lots and Grounds 5 Exterior Surface and Components 7 Garage/Carport 8 Kitchen 8 Living Space

More information

3D Home Improvement and Inspection Services, Inc

3D Home Improvement and Inspection Services, Inc Property Inspection Report Cover Page ABC Disney Lane, Winter Garden FL, 34787 Inspection prepared for: John Doe Inspection Date: 7/15/2010 Time: 11:00 am Age: 6 Years Size: 3,378 LSF / 4,427 TSF Weather:

More information

My Home Was Built In What Can I Expect To See On My Report?

My Home Was Built In What Can I Expect To See On My Report? My Home Was Built In 1956. What Can I Expect To See On My Report? Common Issues in 40 70 Year Old Homes Evidence of foundation settlement Older roof, limited service life remaining Older electrical system

More information

This report is general in nature and not technically exhaustive.

This report is general in nature and not technically exhaustive. BHI, LLC 38 Dana Place / Closter, NJ 07624 NJ Home Inspector Lic. # 24G100020400 NJDEP Radon Lic # Met 109-74 Phone # 201-767-2070 Fax # 201-767-3020 Craig Sharf File Number: 315-062009-xxxx Address of

More information

Continuing Certificate of Occupancy Pre-Inspection Checklist

Continuing Certificate of Occupancy Pre-Inspection Checklist Pre-Inspection Checklist INTRODUCTION: This pre-inspection checklist has been produced to assist you in preparing for a Continuing Certificate of Occupancy (CCO) inspection. The inspection criteria and

More information

Home Inspection Report Report Number: For The Property Located On:

Home Inspection Report Report Number: For The Property Located On: Home Inspection Report Report Number: 416-129 For The Property Located On: Some Place Dr Prepared For Exclusive Use By: John and Jane Doe Report Prepared By: Adam Duncan; License No.: 3533 Inspector Signature:

More information

Sample Home Inspection

Sample Home Inspection Page 1 of 23 Sample Home Inspection Printed Thursday, July 18, 2013 Inspected By: Sample Inspector Referral Information Realtor Client Information: Record Number 3301 Smith, Joe 1 Main St Your town, NJ

More information

The Inspection Process. Waxhaw N.C.

The Inspection Process. Waxhaw N.C. The Inspection Process In Waxhaw N.C. This information is provided by the Waxhaw Enforcement Division to assist you in the progression of your project. Nothing in this document should be considered "Code"

More information

A1-Inspections. Building Inspection Report. (Div of Canada Inc.) Inspection Date: Prepared For: Report Sample

A1-Inspections. Building Inspection Report. (Div of Canada Inc.) Inspection Date: Prepared For: Report Sample A1-Inspections (Div of 6338381 Canada Inc.) Building Inspection Report Inspection Date: 2009-00-00 Prepared For: Report Sample Prepared By: Jim Mollohan 2981 County Rd. #38 Warsaw, ON K0L 3A0 Tel: 705-652-6145

More information

Report. Inspection Date: 01/01/2000. Prepared For: John Q. Public. Prepared By: A1 Certified Home Inspections. Lake City, FL 32024

Report. Inspection Date: 01/01/2000. Prepared For: John Q. Public. Prepared By: A1 Certified Home Inspections. Lake City, FL 32024 A1 Certified Home Inspections Report Inspection Date: 01/01/2000 Prepared For: John Q. Public Prepared By: A1 Certified Home Inspections Lake City, FL 32024 (386) 758-4540 - Office (386) 984-8580 - Cellular

More information

Property Condition Assessment

Property Condition Assessment Property Condition Assessment Pewaukee, WI 53072 Inspection Date: 1/6/15 Prepared For: Report Number: Prepared By: Shamrock Building Inspection Consultants LLC N29 W29951 Shel-Mar Dr. Pewaukee, WI 53072

More information

Home Inspection Report

Home Inspection Report Home Inspection Report 1234 School House Road Yourtown, Yourstate 12345 Prepared for: Mr. and Mrs. Home Buyer Prepared by: 1217 Cape Coral Parkway East #177 Cape Coral, Florida 33904 Phone: (239) 322-0836

More information

1 BASE HOME CONSTRUCTION SPECIFICATIONS: TOWNHOMES 5-13-2015 Note: Specifications noted below may change based on selected options. Verify upgrades from the base specifications with the option sheets and

More information

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS St. Louis County Department of Public Works Division of Code Enforcement HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS This guide is intended to provide the homeowner or contractor with the

More information

TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up

TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM Form 15 Work Write-Up Owner-Builder Applicant Owner-Builder Co-Applicant Physical Address: City,

More information

G. Warren, Inc. Metuchen, NJ Definitions

G. Warren, Inc. Metuchen, NJ Definitions Definitions NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection Appears Serviceable We did not observe conditions that would lead

More information

Property Inspection Report

Property Inspection Report Property Inspection Report 17763 ABC Court San Diego, CA 92131 Page 1 of 26 Table of Contents Definitions 2 General Information 2 Lots and Grounds 2 Exterior Surface and Components 4 Roof 6 Garage/Carport

More information

Canadian Association Of Home & Property Inspectors

Canadian Association Of Home & Property Inspectors Canadian Association Of Home & Property Inspectors National Standards of Practice JuLY 2011 (ver E July 20/11) The National Standards of Practice are a set of guidelines for home and property inspectors

More information

Home Inspection Report. LH Home Services Edgewater McCall, Idaho

Home Inspection Report. LH Home Services Edgewater McCall, Idaho LH Home Services Home Inspection Report 0000 Edgewater McCall, Idaho Prepared for: John Dow Prepared by: P.O. Box 9588 Boise, ID 83707-3588 LH Home Services 17:04PM September 25, 2013 Photo Attachments

More information

RISK Assessment Report. Office Building. Burbank, CA 91506

RISK Assessment Report. Office Building. Burbank, CA 91506 RISK Assessment Report Office Building Burbank, CA 91506 Office Building - Burbank, CA 91506 RISK ASSESSMENT Commercial Real Estate Inspectors 3266 Kirkham Drive Glendale CA 91202 818.957.4654 This is

More information

Pacific Inspection Group Keaau-Pahaoa Rd Keaau, Hawaii Somewhere In Paradise Keaau, Hawaii 96749

Pacific Inspection Group Keaau-Pahaoa Rd Keaau, Hawaii Somewhere In Paradise Keaau, Hawaii 96749 16-566 Keaau-Pahaoa Rd Keaau, Hawaii 96749 Somewhere In Paradise Keaau, Hawaii 96749 08:35 April 17, 2015 Page 1 of 12 Table of Contents Definitions 2 General Information 2 Lots and Grounds 3 Exterior

More information

BASEMENT FINISH CONSTRUCTION PLANS REFERENCE: 2015 INTERNATIONAL RESIDENTIAL CODE. PERMITS

BASEMENT FINISH CONSTRUCTION PLANS REFERENCE: 2015 INTERNATIONAL RESIDENTIAL CODE. PERMITS BASEMENT FINISH REFERENCE: 2015 INTERNATIONAL RESIDENTIAL CODE. PERMITS A construction permit is required. A homeowner may perform the construction work on his own property where he resides, without a

More information

Canadian Association Of Home & Property Inspectors

Canadian Association Of Home & Property Inspectors Canadian Association Of Home & Property Inspectors National Standards of Practice September 2010 (ver d Sept 15/10) The National Standards of Practice are a set of guidelines for home and property inspectors

More information

Standards of Practice for Building Inspections, recognized by the OACIQ

Standards of Practice for Building Inspections, recognized by the OACIQ NATIONAL BUILDING INSPECTORS AND EXPERTS ASSOCIATION Standards of Practice for Building Inspections, recognized by the OACIQ (l Organisme d autoréglementation du courtage immobilier du Québec) November

More information

The following is the Standards of Practice (SOP) for Home Inspectors required by the state of Florida.

The following is the Standards of Practice (SOP) for Home Inspectors required by the state of Florida. Prepared by FL NACHI 3/21/2012 www.flnachi.org The following is the Standards of Practice (SOP) for Home Inspectors required by the state of Florida. 61-30.801 Standards of Practice, General (1) The purpose

More information

Choice Home Inspection Services, Inc.

Choice Home Inspection Services, Inc. Cover Page Property Inspection Report Inspection prepared for: Mr. and Mrs. Client Date of Inspection: 4/11/2017 Time: 2:00 PM Age of Home: 2001 Size: 1952 Order ID: 1470 Inspector: ASHI #212073 InterNachi

More information

Maine Coalition of Home Inspection Professionals (MeCHIPs) STANDARDS OF PRACTICE Adopted on: 12/05/00, Revised 4/7/09, 1/5/10, 1/3/12, 1/7/13

Maine Coalition of Home Inspection Professionals (MeCHIPs) STANDARDS OF PRACTICE Adopted on: 12/05/00, Revised 4/7/09, 1/5/10, 1/3/12, 1/7/13 Maine Coalition of Home Inspection Professionals (MeCHIPs) STANDARDS OF PRACTICE Adopted on: 12/05/00, Revised 4/7/09, 1/5/10, 1/3/12, 1/7/13 These Standards may not be reproduced without written permission

More information

123 Main Street Anytown, IL 12345

123 Main Street Anytown, IL 12345 123 Main Street Anytown, IL 12345 JANE HOMEOWNER Tuesday, October 1, 2013 Alan Carson Scan to download report XYZ Home Inspection Services 120 Carlton St, Suite 407 Toronto, ON M5A 4K2 800-268-7070 Horizon@carsondunlop.com

More information

RESIDENTIAL BUILDING PLAN REQUIREMENTS

RESIDENTIAL BUILDING PLAN REQUIREMENTS CITY OF MANSFIELD BUREAU OF BUILDING AND CODES 30 NORTH DIAMOND STREET 3RD FLOOR MANSFIELD, OHIO 44902 Phone (419) 755-9688 Fax (419) 755-9453 www.ci.mansfield.oh.us RESIDENTIAL BUILDING PLAN REQUIREMENTS

More information

Home Inspection Report

Home Inspection Report Home Inspection Report Mr. Mrs. Property Address: 123 Main Street Any Town GA 30000 Champ Home Inspections Inc. Jim Champ 770-516-8882 Office 770-367-4123 Cell 678-494-0171 Fax www.champhomeinspections.com

More information

Canadian Association Of Home & Property Inspectors

Canadian Association Of Home & Property Inspectors Canadian Association Of Home & Property Inspectors 2012 National Standards of Practice The National Standards of Practice are a set of guidelines for home and property inspectors to follow in the performance

More information

Watson Home Inspection Services, LLC.

Watson Home Inspection Services, LLC. Cover Page Watson Home Inspection Services, LLC. Property Inspection Report 1234 Anywhere Lane, Yourtown Ca, 92555 Inspection prepared for: Steven Smith & Susan Smith Agent: Alan Smith - Inspection Date:

More information

INSPECTION REPORT October 13, 2017

INSPECTION REPORT October 13, 2017 P.O. BOX 311 GLENWOOD SPRINGS, CO 81602 970-309-4709 INSPECTION REPORT October 13, 2017 Inspection For: Lakota HOA c/o Sonny Black 151 Clubhouse Drive New Castle, CO 81647 970-355-9552 sonninc@aol.com

More information

How's My House Home Inspections LLC

How's My House Home Inspections LLC Cover Page How's My House Home Inspections LLC Property Inspection Report 319 YZ street, Anytown New York, 11121 Inspection prepared for: John Sample Agent: Real Estate - ABC Realty Inspection Date: 1/12/2011

More information

Sample Pre-drywall Inspection Report

Sample Pre-drywall Inspection Report Inspector's email: inspectmorellc@gmail.com Inspector's phone: (404) 661-9763 PO Box 3755 Suwanee GA 30024-0995 Inspector: Joe Moore Client(s): Property address: Inspection date: This report published

More information

HOME INSPECTION REPORT

HOME INSPECTION REPORT HOME INSPECTION REPORT 123 Main St. Anytown, NJ Inspection Date: 07/07/2010 Prepared For: Jane & John Doe Prepared By: A Pro Home Inspection Services 12 Ervin Dr. Yardville, NJ 08620 609/585-0012 609/585-6838

More information

Healthy Homes Provisions of Lansing, Michigan Ordinances Extracted from by National Center for Healthy Housing

Healthy Homes Provisions of Lansing, Michigan Ordinances Extracted from  by National Center for Healthy Housing TITLE 6. HOUSING CHAPTER 1460. HOUSING AND PREMISES CODE Selected Provisions Related to Healthy Homes 1460.02. Applicability. (h) Historic Buildings. The provisions of this Code shall not be mandatory

More information

HOME INSPECTION REPORT

HOME INSPECTION REPORT HOME INSPECTION REPORT Bayminette, AL Prepared exclusively for John & Kristen Prepared by Ellis Inspection Services, Inc. AL 251.943.4696 FL 850.492.7258 www.ellishomeinspections.com FL(850) 492.7258 /

More information

SUMMARY. Appliance: Corrective Action(s)

SUMMARY. Appliance: Corrective Action(s) Appliances: Range/Oven/Cooktop Appliance: Corrective Action(s) Finding # 1 **Range anti-tip bracket is not installed. Anti-tip brackets are safety devices installed to prevent the range from tipping forward.

More information

Radon Vent Pipe System. Labeling Performance Indicators

Radon Vent Pipe System. Labeling Performance Indicators Section 6 Radon Vent Pipe Labeling Performance Indicators Radon Vent Pipe System Connected after sub-grade system installed Pipe cannot be trapped Provide space in chases Support at each floor level Discharge

More information

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210)

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210) Quality Inspection 8618 London Heights San Antonio, TX 78254 Phone: (210) 240-0476 PRE DRYWALL INSPECTION REPORT Prepared For: DELETED (Name of Client) Concerning: DELETED, San Antonio, TX 78258 (Address

More information

Inspection Report. July 10, Sample Report. Property Address: 123 Main St. Any town Va Hallmark Residential Services, Inc.

Inspection Report. July 10, Sample Report. Property Address: 123 Main St. Any town Va Hallmark Residential Services, Inc. Inspection Report July 10, 2015 Property Address: 123 Main St. Any town Va 22551 Hallmark Residential Services, Inc. Karl Colbrunn 9811 Deer Park Dr. Spotsylvania, Va. 22551 540-273-7453 123 Main St. Page

More information

2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property 2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical

More information

The conditions, recommendations, suggestions contained herein are the result of a visual inspection as of this date.

The conditions, recommendations, suggestions contained herein are the result of a visual inspection as of this date. HOME INSPECTION ENGINEERS LICENSED PROFESSIONAL ENGINEERS 926 Haddonfield Road, Suite E PMB 162 Cherry Hill, NJ 08002 800-676-7879 Phone 856-482-6615 Fax 856-667-8401 In accordance with your request, the

More information

InterNACHI. Advanced Inspection of Crawlspaces for home inspectors

InterNACHI. Advanced Inspection of Crawlspaces for home inspectors CRAWLSPACE INACCESSIBLE Crawlspace conditions which in the Inspector s opinion posed a personal safety hazard limited examination of the crawlspace to only those home systems and their components visible

More information

Property Inspection Report

Property Inspection Report Page 1 of 14 Property Inspection Report Inspector Information Client Information Mike Williams Christella Padilla (Buyer's Realtor) Blue Sky Home Inspections, LLC Coldwell Banker Legacy PO Box 67845 6767

More information

Checklist #1 Questions to Ask Real Estate Agents

Checklist #1 Questions to Ask Real Estate Agents Checklist #1 Questions to Ask Real Estate Agents Whether you re selling or buying, hiring the right agent can be an important part of the home inspection process. Don t be afraid to ask lots of questions

More information

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection Slab on Grade & Basements: A capillary break is installed on top of all footings Slab / Pre-Drywall / Thermal Inspection A minimum of 4" of clean or washed gravel (0.5" diameter or greater) is placed over

More information

Close-Up Home Inspection Home Inspection Report

Close-Up Home Inspection Home Inspection Report Home Inspection Report 1 Sample rd Anytown, Ma 00000 Page 1 of 19 Sample Report - Copy.inspx Table of Contents Definitions 2 Company Information 2 General Information 2 Home History Questionnaire 3 Lots

More information

Post Office Box 867, Dunedin Florida Tel: (727) Fax: (727)

Post Office Box 867, Dunedin Florida Tel: (727) Fax: (727) www.britanniabci.com Post Office Box 867, Dunedin Florida 34697-0867 Tel: (77) 446-00 Fax: (77) 46-375 Property Inspected for: 0 Property Address: 0 Tampa, Florida Date of inspection: Thursday, October

More information

This is an actual inspection report

This is an actual inspection report This is an actual inspection report Report Prepared For: Client information has been removed Report Prepared By: Aaron Pfaff, Dedicated Home Services LLC TABLE of CONTENTS TABLE of CONTENTS... 2 GENERAL

More information

Storm Damage Assessment Report For: 1234 Example Street., Houston, TX 77002

Storm Damage Assessment Report For: 1234 Example Street., Houston, TX 77002 Storm Damage Assessment Report For: 1234 Example Street., Houston, TX 77002 Prepared For: Miriam Saliba nspection Date: 9/6/2017 Prepared By: Adam Wells TREC License # 21140 105 E Spreading Oaks Ave, Friendswood,

More information

PREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and

PREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and PREP + INSULATION HOME ENERGY UPGRADES What every contractor needs to know. Copyright 2012 Advanced Energy. All Rights Reserved 103 HOME ENERGY UPGRADES Prep + Insulation Contents Air sealing is a challenging

More information

Training Certification Categories

Training Certification Categories Training Certification Categories Residential Residential Building Inspector structures are free from hazardous structural conditions and comply with the UCC. Duties include inspection of footings and

More information

Building Inspection Report

Building Inspection Report Building Inspection Report Sample Commercial Inspection Report Inspection Date: Prepared For: Prepared By: Professional Property Inspection Consultants 4857 Winterset Drive Columbus, OH 43220 (614) 459-5941

More information

SAMPLE ROOFING INSPECTION REPORT

SAMPLE ROOFING INSPECTION REPORT SAMPLE ROOFING INSPECTION REPORT PROPERTY ADDRESS: 110 Santa Clara Avenue, San Francisco, California DATE OF INSPECTION: 9/23/16 10/4/16 10/5/16 TIME: 10:00 AM 12 PM ORIGINAL REPORT SENT TO: Eden Gallanter

More information

Greater Dayton Home Inspections

Greater Dayton Home Inspections Cover Page Greater Dayton Home Inspections Property Inspection Report 12345 Inspection prepared for: John Sample Date of Inspection: 6/1/2012 Time: 3PM to 7:15PM Age of Home: 12 Years Size: 2,600 Square

More information

Edouard AVANT GROVE U I C U I C. Modern Living Made Easy uichomes.com

Edouard AVANT GROVE U I C U I C. Modern Living Made Easy uichomes.com Edouard Modern Living Made Easy uichomes.com - new construction - 3 stories + full basement - 4 bedrooms - 2.5 baths - 2,380 s.f. call 314.881.2333 or e-mail sales@uicstl.com PLAN NTS DECK 13' 0" X 12'-0"

More information

PROPERTY INSPECTION REPORT - Example

PROPERTY INSPECTION REPORT - Example PROPERTY INSPECTION REPORT - Example Prepared For: Smart Buyer or Seller (Name of Client) Concerning: Anystreet, Anytown Texas (Address or Other Identification of Inspected Property) By: Jeff Wampler TREC#

More information

Feasibility Report. Property Inspection Engineers, Inc. (248) Property Address. 405 Fairgrove Royal Oak, MI.

Feasibility Report. Property Inspection Engineers, Inc. (248) Property Address. 405 Fairgrove Royal Oak, MI. Feasibility Report Property Inspection Engineers, Inc. (248) 644-8798 Inspection ate: 10/27/2010 Consultant's Job No: Consultant: Christopher J. aggy Applicant ark Beard Property Address 405 Fairgrove

More information

Presented by The National Association of Certified Home Inspectors Chicago Chapter

Presented by The National Association of Certified Home Inspectors Chicago Chapter Top 10 Defects Found in New Homes Presented by The National Association of Certified Home Inspectors Chicago Chapter - The National Association of Certified Home Inspectors 1 Top 10 New Home Defects New

More information

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) PERMIT SUBMITTAL CHECKLIST: Signed and completed Building Permit application form. A separate Electrical permit is required from

More information

REQUIREMENTS FOR SUBSTANTIALLY DAMAGED AND SUBSTANTIALLY IMPROVED STRUCTURES

REQUIREMENTS FOR SUBSTANTIALLY DAMAGED AND SUBSTANTIALLY IMPROVED STRUCTURES REQUIREMENTS FOR SUBSTANTIALLY DAMAGED AND SUBSTANTIALLY IMPROVED STRUCTURES If your home or business incurred damage, the engineering department, in conjunction with the Flood Mitigation Officer, will

More information

PROPERTY INSPECTION REPORT

PROPERTY INSPECTION REPORT PROPERTY INSPECTION REPORT Prepared For Exclusive Use By Thomas and Mary Smith For The Property Located At 1035 Presidio Drive, San Diego, California 92131 This inspection report is the narrative counterpart

More information

Your Company Name Goes Here. Your Company Name Goes Here

Your Company Name Goes Here. Your Company Name Goes Here *** Residential Inspection Report *** Client s Name John Doe TheLogo's below are there only as a On February 3, 2011 Inspection Address 105 Via Santo Tomas Rancho Mirage, Ca. 92270 By Mr Inspector Your

More information

Crawl Space Moisture Control

Crawl Space Moisture Control Crawl Space Moisture Control Crawl space foundations are found in many homes. Typically, these foundation types are equipped with operable vents designed to provide ventilation for moisture control. Unfortunately,

More information

Inspection Source. Property Inspection Report

Inspection Source. Property Inspection Report Cover Page Inspection Source Property Inspection Report 95669 Inspection prepared for: Frank Axe & Kathy Allen-Axe Real Estate Agent: Jennifer Nelson - All Power Brokers Date of Inspection: 11/8/2012 Time:

More information

CITY OF GRANDE PRAIRIE

CITY OF GRANDE PRAIRIE Inspection Services CITY OF GRANDE PRAIRIE HOMEOWNER S PERMIITS AND WIRING GUIDE FOR ELECTRICAL INSTALLATIONS 2016 INDEX Page Applying for an Electrical Permit 3 Permit Application Requirements 3 Permit

More information

Clients Name 123 Pleasant Valley Drive Any Town, OH 00000

Clients Name 123 Pleasant Valley Drive Any Town, OH 00000 Ed Nye, Business Owner Phone: 740-815-5312 Email: ednye@fortehomeinspections.com Website: www.fortehomeinspections.com 3059 Braumiller Rd, Delaware, Oh 43015 Clients Name 123 Pleasant Valley Drive Any

More information

Premium Home Inspections. Inspection Report. Please read your report thoroughly!

Premium Home Inspections. Inspection Report. Please read your report thoroughly! Premium Home Inspections Inspection Report Please read your report thoroughly! (860) 889-7246 www.hoffnerinspections.com Report Table of Contents INSPECTION CONDITIONS GROUNDS 5 EXTERIOR 7 ROOF SYSTEM

More information

Typical Finished Basement Details

Typical Finished Basement Details Albemarle County, Virginia Typical Finished Basement Details Based on the 2012 Virginia Residential Code Finished basements must be constructed in conformance with these details. For requirements, details

More information

Integrity Home Inspection & Testing, LLC

Integrity Home Inspection & Testing, LLC 1 of 46 Integrity Home Inspection & Testing, LLC Larry G. Karschner 8 Redwood Drive Kearney, NE 68845 Email: lkarschner@frontiernet.net Phone: 308-627-5471 Fax: 308-234-4804 Web: www.kearneyhomeinspections.com

More information

First Choice Inspections

First Choice Inspections *** Residential Inspection Report *** Double Click Here to Insert Photo Client s Name Bill Johnson On July 17th 2010 Inspection Address 712 Smith Drive Hudson, WI 54016 By Matt Rappel First Choice Inspections

More information

Chapter 3. Standards of Practice

Chapter 3. Standards of Practice Chapter 3. Standards of Practice 301. Minimum Standards A. This Chapter sets forth the minimum Standards of Practice required of licensed home inspectors. Economic Development, Board of Home Inspectors,

More information

Davis Frame Co., Inc. Construction Budget Considerations

Davis Frame Co., Inc. Construction Budget Considerations Davis Frame Co., Inc. Construction Budget Considerations ITEM BID 1 BID 2 BID 3 MISCELLANEOUS COSTS Surveying Building Permit Engineering Fees Interest on Construction Loan Property Taxes Hazard & Liability

More information

CERTIFICATE of OCCUPANCY APPLICATION RESIDENTIAL

CERTIFICATE of OCCUPANCY APPLICATION RESIDENTIAL 24 hour inspection line 737.793.1656 Date CERTIFICATE of OCCUPANCY APPLICATION RESIDENTIAL 1. Building Information Property address Property ID Type of Housing (please circle): OWNER OCCUPIED RENTAL HOME

More information

One and Two Family Additions

One and Two Family Additions One and Two Family Additions An addition to a house, duplex, garage, or an accessory structure requires a building permit prior to performing any construction. Building Department & Permit Office Mon-Fri

More information

Encapsulated, Sealed & Closed Crawlspace Installation Manual

Encapsulated, Sealed & Closed Crawlspace Installation Manual YourCrawlSpace, Inc. 1007 Johnni4 Dodds Blvd. Mt. Pleasant, SC 29464 Toll Free: 877-44-CRAWL (27295) Local: (843) 593-1115 Encapsulated, Sealed & Closed Crawlspace Installation Manual Copyright 2017 Your

More information

CHARTRES COURT Washington Avenue Houston, Texas ChartresCourtHouston.com CHARTRES COURT LLC

CHARTRES COURT Washington Avenue Houston, Texas ChartresCourtHouston.com CHARTRES COURT LLC CHARTRES COURT 713-868 - 7226 5023 Washington Avenue Houston, Texas 77007 ChartresCourtHouston.com CHARTRES COURT LLC Features Open floor concept living/dining with spacious island kitchen Great master

More information

RESIDENTIAL BUILDING REQUIREMENTS

RESIDENTIAL BUILDING REQUIREMENTS RESIDENTIAL BUILDING REQUIREMENTS Residential Building Requirements This is an informational booklet with some of the general residential construction requirements taken from the codes adopted by Campbell

More information

Truth in Sale of Housing Disclosure Report NOTICE - Read Entire Report Carefully. This is not a Buyer's Inspection!

Truth in Sale of Housing Disclosure Report NOTICE - Read Entire Report Carefully. This is not a Buyer's Inspection! NOTICE - Read Entire Report Carefully. This is not a Buyer's Inspection! Current Owner Name: FREDDIE MAC Contact: FREDDIE MAC Business/Relationship: Owner Address: C/O 8937 AZTEC DRIVE I declare to the

More information

Collier Home Inspections, LLC

Collier Home Inspections, LLC Cover Page Collier Home Inspections, LLC Property Inspection Report, 33912 Inspection prepared for: Report Sampe Agent: Ronald Monald - Collier Home Inspections, LLC Inspection Date: 8/19/2010 Time: 12:30

More information

Standard Home Inspection Report

Standard Home Inspection Report Standard Home Inspection Report Subject Property Subject Property File Number: 05-15-011 Status of Property: Type of Property: Square Footage: occupied Single Family Home 3300± Total SF (not verified)

More information

Beneficial. Home Inspections. Your Home Inspection Report. John Doe. Customer Name - 02/30/2002. Inspection Date Sample Drive Inspection TX

Beneficial. Home Inspections. Your Home Inspection Report. John Doe. Customer Name - 02/30/2002. Inspection Date Sample Drive Inspection TX Beneficial Home Inspections Your Home Inspection Report Customer Name - Inspection Date - Address - John Doe 02/30/2002 1111 Sample Drive Inspection TX Beneficial Home Inspections Business Phone 512-719-5090

More information

FAIRA TRANSPARENCY REPORTS S Ponderosa Ln, Spokane Valley, WA October 24 th, 2017

FAIRA TRANSPARENCY REPORTS S Ponderosa Ln, Spokane Valley, WA October 24 th, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 4419 S Ponderosa Ln, Spokane Valley, WA 99206 Thank you for your interest in this Faira Certified

More information

Legacy Home Inspections

Legacy Home Inspections Cover Page Legacy Home Inspections Home Inspection Report 66215 Inspection prepared for: Robert & Patricia Smith Date of Inspection: 4/1/2016 Inspector: Robert Ladd 7922 Darnell Lane, Lenexa, KS 66215

More information

MOLD INSPECTION REPORT Block Home Inspections LLC

MOLD INSPECTION REPORT Block Home Inspections LLC Block Home Inspections LLC David Block - 913-220-7762 MOLD INSPECTION REPORT Block Home Inspections LLC David M. Block Certified Mold Inspector #CMI-06-2024 INSPECTION AGREEMENT Mold screening is intended

More information

Boise Home Inspection Report

Boise Home Inspection Report Boise Home Inspection Report 514 Wilbur Rd, Farmville, ID 12345 Inspection Date: 3/21/2014 Prepared For: Charlotte Prepared By: Boise Home Inspections 8390 W Harmonica Way Boise, ID 83709 (208) 794-3483

More information

Advanced Ventilation for Residential applications FBC Res 2010.

Advanced Ventilation for Residential applications FBC Res 2010. Advanced Ventilation for Residential applications FBC Res 2010. Course Description Review of the Residential Ventilation requirements in the Florida Building Code, Residential 2010. I. Introduction Dean

More information

Seal Harbor Development 1 Nagog Park Acton, MA 01720

Seal Harbor Development 1 Nagog Park Acton, MA 01720 Seal Harbor Development 1 Nagog Park Acton, MA 01720 Specifications for Ocean Mist Villages Foundation and Concrete Floors Footings All footings are constructed and poured with 3000 lb mix, continuous

More information

A/E Design Deliverable Checklist

A/E Design Deliverable Checklist A/E Design Deliverable Checklist Design deliverables for the Design Development phase shall include all items listed in the Design Development column as well as those all items listed in the Schematic

More information

Applying for Permits to build a new house in Linn County

Applying for Permits to build a new house in Linn County Planning & Development Linn County, Iowa Building Division Linn County Building Code Residential Guidelines Single Family Dwellings Page 1 of 4 Applying for Permits to build a new house in Linn County

More information

In Depth Home Inspection LLC Report # Doe STRUCTURAL PESTS & DRY ROT INSPECTION REPORT

In Depth Home Inspection LLC Report # Doe STRUCTURAL PESTS & DRY ROT INSPECTION REPORT ADDRESS OF 123 Main Ave NE DATE OF INSPECTION PROPERTY Salem OR 97301 Feb 1, 2010 INSPECTED Inspection ordered by John and Jane Doe Report sent to John and Jane Doe Owner's Name & Address John and Jane

More information

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1% CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE EXAM ID: I1 80 multiple-choice questions 3-1/2-hour time limit Open book 01. GENERAL ADMINISTRATION 6% 0101. Project Administration 1% Verify that

More information

Basic Requirements for Residential Electrical Installations

Basic Requirements for Residential Electrical Installations Basic Requirements for Residential Electrical Installations Wayne County Building Department 428 West Liberty Street Wooster, Ohio 44691 Phone: 330-287-5525 Fax: 330-287-5649 This brochure is intended

More information

BUILDING PERMIT INFORMATION GUIDE FOR THE HOMEOWNER

BUILDING PERMIT INFORMATION GUIDE FOR THE HOMEOWNER THE CORPORATION OF THE MUNICIPALITY OF SOUTH HURON 322 Main Street South, P.O. Box 759, Exeter, Ontario N0M 1S6 PHONE: (519) 235-0310 FAX: (519) 235-3304 TOLL FREE: 1-877-204-0747 WEBSITE: www.southhuron.ca

More information