Building regulations now in force

Size: px
Start display at page:

Download "Building regulations now in force"

Transcription

1 BCA Section J: Guide to compliance Publication date July 2008

2 Building regulations now in force BCA SECTION J: Mandatory energy efficiency measures for non-residential construction The new BCA Section J, which came into force in 2006 will change the way we build. It sets new standards for long term insulation and environmental performance of components and construction methods. It is the responsibility of all involved in the construction industry to understand and comply with the new mandatory provisions of BCA Section J. This includes: designers specifiers engineers building contractors owners investors Section J covers all Class 2 to 9 buildings (residential and commercial buildings). It aims to reduce greenhouse gas emissions by increasing energy efficiency of structures. Affects all air conditioned and many non-air conditioned buildings. Specific areas of focus include: Loss of energy through heating/cooling leakage through building fabric roof, ceilings, walls and floors External glazing to reduce heat gain and place less pressure on air conditioning Sealing to reduce leakage around chimneys, flues, windows, doors and other projections Air movement and ventilation to reduce air conditioning needs Design of air conditioning systems to prevent excessive power consumption Section J regulations are different for each class of structure and climate zone in Australia. The building code of Australia Section J: Mandatory energy efficiency measures for non-residential construction The Building Code of Australia (BCA) Section J (mandatory energy efficiency measures for non-residential construction) regulation aims to reduce greenhouse gas emissions from buildings. This regulation has been developed in consultation with state, territory and local governments, building practitioners, industry and the community. State Australian Capital Territory Implementation dates Adoption date 1 May 2006 New South Wales 1 November 2006 Northern Territory 1 May 2006 Queensland 1 May 2006 South Australia 1 August 2006 Tasmania 1 May 2006 Victoria 1 May 2006 Western Australia 1 May 2006 Energy efficiency measures were initially introduced into the BCA housing provisions in In 2005, mandatory measures were introduced into the BCA for Class 2-4 buildings. This was followed up in 2006 with similar measures for Class 5-9 buildings. All of the BCA provisions are now mandatory for Class 2 to 9 buildings (refer to the appendix description for building classes). Buildings with HVAC are particularly affected by the new regulations. Greenhouse gas emissions The Australian government has committed to achieving specific greenhouse reductions as part of the Kyoto Protocol, which came into effect in Section J in building construction is a key project in the steps taken to achieve these emission targets. Compliance to Section J Automatic compliance to Section J mandatory regulations can be achieved by meeting the BCA prescribed building solutions, called Deemed to Satisfy provisions. There is provision for alternative engineered solutions, which will require documentary evidence, verification, comparative analysis or expert judgement. New energy efficiency measures The incorporation of energy efficiency measures in the BCA is targeted towards ongoing operational efficiencies over the life of buildings. The BCA sets standards for the performance of buildings, including services that aid the efficient use of energy. Section J incorporates the use of the building, the method of construction, its geographic location, the effects of nearby features such as landforms, structures and buildings, and solar radiation considerations. The mandatory energy efficiency requirements vary according to the Class of building and are also based on the climate zone. Australia is divided into geographical zones (see map, also available on the ABCB website). Different levels of energy efficiency are required, based on the climate severity for each building being designed.

3 Specific areas targeted by the BCA for improvement are: 1. Building fabric The building fabric the basic components of a building, including the roof, ceilings, walls and floors should have sufficient thermal resistance to ensure that energy is not lost by heat transmission. Roof, ceiling, walls and floors must achieve a specified total R value (which is the total sum of the insulating performance of all individual component layers, including any 2. building material, insulating material, airspace and associated surface resistances). External glazing There are regulations to ensure that the amount of heat gain through windows is not excessive and that air conditioning needed to counteract the heat losses through windows is not excessive. Shading of the building and glazing orientation are also factors that can affect heat loss or gain Building sealing Building sealing effectiveness can not only influence the size of air conditioning HVAC in building design, it can also influence longer term energy operating consumption. The BCA requires sealing around chimneys, flues, windows doors and other projections. The building fabric around roofs, walls and floors also needs to be constructed to minimise air leakage. Air movement Air movement within a building offers a form of cooling, so that air conditioning requirements can be reduced. Ventilation requirements vary by building class and climate zone. There are also restrictions on the fixing method and size for ceiling fans or evaporative coolers. Air conditioning and ventilation systems Air conditioning must be able to operate at different temperatures and times to meet the intended use of the building. The design of the HVAC system in terms of motor power and ventilation/exhaust must prevent excessive energy consumption. Artificial lighting and power The number of lights and power consumption are to be regulated to within acceptable maximum levels. Hot water supply Hot water systems must be designed and installed in accordance with Section 8 of AS/ANZ plumbing and drainage heated water services. Access for maintenance There are maintenance measures that must be provided to all plant, equipment and components that require maintenance, to ensure that they operate at efficient levels. Summary Section J energy efficiency measures are implemented through the local standard building approvals process, involving building inspectors and surveyors, and often independent building certifiers and assessors. Building designers and builders themselves need to be aware of these new requirements. The Section J implications for building construction are complex, and vary according to the class of building and also with the climate zone. From Kingspan s experience worldwide where similar regulations have been introduced, it has been the signal/catalyst for further regulations to be developed. Likely further developments include mandatory air leakage testing, regulations being extended across all classes of buildings, the requirement for thicker insulation, the implementation of elemental calculations and the anticipation of change of tenancy. For further information contact your state based ABCB office. Additional information can also be obtained from their website at

4 Typical insulation requirements for the building envelope under Section J Roofs and ceilings Climate zone 1 2a 2b Class 2 or 3 building, Class 4 part of building or Class 9c aged care building Total R Direction of heat flow Down Down and Up Up Class 5, 6, 7, 8, 9a or 9b building Total R Direction of heat flow Down Up Walls Climate zone 1 2a 2b Class 2 or 3 building, Class 4 part of building or Class 9c aged care building Total R Class 5, 6, 7, 8, 9a or 9b building Total R Where do conventional non-compliant systems sit under Section J? Typical R values achieved with conventional non-compliant roof construction Typical R values achieved with conventional non-compliant wall construction Construction method and materials Typical R value** Construction method and materials Typical R value** Metal deck, cavity, reflective foil, cavity, bulk insulation*, plasterboard 1.14 Concrete tilt-up panel (100mm), bulk insulation*, with furring channel and plasterboard finish 0.28 Metal deck, bulk insulation* with 0.77 reflective foil laminate, cavity, plasterboard These figures assume best practice installation and the absence of insulation voids * The value of the bulk insulation to be added to the typical R value. A typical R value for bulk insulation of 50mm would be R and may vary depending on the product selected ** Different levels of thermal performance can be achieved, based on summer or winter climatic conditions and the use of reflective foils. The minimum value (or winter condition) is the one that in general needs to meet the minimum BCA level of performance and is the value given here 110mm brick wall with internal stud frame and plaster lining Cement clad wall, reflective foil laminate, reflective cavity, bulk insulation*, plasterboard Double brick cavity wall, with furring channels and plasterboard

5 New concept insulated panels a compliance solution Thermal insulation thickness Kingspan insulated panels were developed for construction efficiency. They provide energy efficient solutions that are already compliant with BCA Section J and are widely used in markets where such regulations have long been in force. The external envelope must be procured under one package with a single point of responsibility for design detailing, supervision and installation, rather than as individual building elements. This is at the heart of the Kingspan concept. Minimum compliance requirements from May 2006 (November 2006 for NSW). Please note where light colours with high reflective values are used in certain climate zones there is a provision under Section J where the minimum thickness can be reduced from Kingspan 60mm to 40mm. Contact the Kingspan technical services for further information on KS1000 RW Core thickness (mm) R value (m 2 K/W) Weight kg/m 2 0.5/0.4 steel An airtight envelope Building with Kingspan insulated panels guarantees you an airtight envelope. The inherent thickness and structural rigidity of Kingspan insulated panels together with factory-engineered joints and robust details ensures minimal air leakage. Long term thermal performance Kingspan insulated roof and wall panels are guaranteed to retain their thermal performance for the life of the product thereby helping to ensure that the building energy performance rating is maintained throughout the life of the building. The easy way to become compliant The easy way to become compliant in all cases is to choose Kingspan as your guide to selecting building systems. Kingspan s range of roofing and wall panel systems already complies with Section J. You can spend precious time trying to understand it or you can call Kingspan for expert advice on References [1] Australian Building Codes Board, BCA 2006, Class 2 to 9 Buildings, Volume One, 2006 [2] Australian Greenhouse Office, Tracking to the Kyoto Target Australia s Greenhouse Emissions Trends 1990 to and 2020, 2006 Appendix: BCA building classifications used in nonresidential construction Class 4: Class 5: Class 6: Class 7a: A dwelling part of a building in Class 5, 6, 7, 8 or 9 Office buildings Shop or other buildings for the sale of goods, eg restaurant, barber s shop, laundry, market, showroom and service station Car parks Class 2: Two or more sole-occupancy Class 7b: Storage or display of goods Class 3: Boarding houses, guest houses, hostels, Class 8: Laboratories, production areas lodging-houses or backpackers accommodation. A residential part of a hotel, motel, school, a health care building or a detention centre. Buildings for the aged, children or disabilities Class 9a: Class 9b: A health-care building Assembly buildings, trade workshops, laboratories in schools accommodation Class 9c: Aged care buildings

6 Kingspan Insulated Panels Pty Limited Dunheved Circuit St Marys NSW 2760 Tel Fax Care has been taken to ensure that the contents of this publication are accurate, but Kingspan Insulated Panels Pty Limited and its subsidiary companies do not accept responsibility for errors or for information that is found to be misleading. Suggestions for, or descriptions of, the end use or application of products or methods of working are for information only and Kingspan Insulated Panels Pty Limited and its subsidiaries accept no liability in respect thereof. KING1545

Great Ocean Rd Ice Creamery

Great Ocean Rd Ice Creamery Great Ocean Rd Ice Creamery BCA Section J - JV3 Compliance Report Revision: 01 Job No: 2171 Date: 7 July 2015 ADP Consulting Pty Ltd Level 10, 10 Queens Rd, Melbourne Vic 3004 www.adpconsulting.com.au

More information

BCA Section J Compliance Report. Alterations & Additions to Cottage at St Johns College 10 Missenden Road Camperdown

BCA Section J Compliance Report. Alterations & Additions to Cottage at St Johns College 10 Missenden Road Camperdown BCA Section J Compliance Report Alterations & Additions to Cottage at St Johns College 10 Missenden Road Camperdown Prepared by: Gradwell Consulting ABN 68 872 791 784 Sustainability Consultants PO Box

More information

RENOVATIONS & REFURBISHMENTS

RENOVATIONS & REFURBISHMENTS RENOVATIONS & REFURBISHMENTS This Activity received funding from the Department of Industry as part of the Energy Efficiency Information Grants Program The nature of the tourism and hospitality industries

More information

Insulated Roof & Wall Panels. Foilback KS1000 FB Insulated Roof Panels. Product Data Sheet

Insulated Roof & Wall Panels. Foilback KS1000 FB Insulated Roof Panels. Product Data Sheet Insulated Roof & Wall Panels Foilback KS1000 FB Insulated Roof Panels Overview Kingspan Foilback is supplied with a pre-painted Steel external (Aluzinc also available on request) with a choice of silver

More information

THERMAL MASS CHAPTER 6. Understanding thermal mass. Seasonal effects of thermal mass

THERMAL MASS CHAPTER 6. Understanding thermal mass. Seasonal effects of thermal mass CHAPTER 6 THERMAL MASS mud brick concrete block brick The contents of this chapter explain the effect of thermal mass and provide guidelines for its location and extent. Summer and winter effects of thermal

More information

Controlled Environments. Product Data Sheet. Controlled Environment Panel System KS1100 CS

Controlled Environments. Product Data Sheet. Controlled Environment Panel System KS1100 CS Controlled Environments Controlled Environment Panel System KS1100 CS Overview Kingspan controlled environment panel systems are designed for use within temperature controlled and hygiene safe environments

More information

What you need to know about 6 Star. 6 Star. for new homes, home renovations, alterations, additions and relocations

What you need to know about 6 Star. 6 Star. for new homes, home renovations, alterations, additions and relocations What you need to know about 6 Star 6 Star for new homes, home renovations, alterations, additions and relocations Introduction From 1 May 2011, all new homes, home renovations, additions, alterations and

More information

APR TECHNICAL note. Six-Star Concrete Housing. Six-Star Concrete

APR TECHNICAL note. Six-Star Concrete Housing. Six-Star Concrete 70 APR 2013 TECHNICAL note Six-Star Housing Six-Star Housing PREFACE This Technical Note provides architects, designers and other building professionals with information on how houses* incorporating concrete

More information

Insulwhite. Insulation WHITE-FACED THERMO REFLECTIVE INSULATION

Insulwhite. Insulation WHITE-FACED THERMO REFLECTIVE INSULATION Insulation A4/6 TB055W AW2244 Issue 6 Oct 2017 WHITE-FACED THERMO REFLECTIVE INSULATION Innovative cross-linked closed cell insulation core 3-in-1 Insulation, vapour barrier and radiant barrier Helps achieve

More information

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS INTRODUCTION BENCHMARK Wall Liner is an engineered insulated panel system that is ideal for fully supporting single skin metal sheeting such as zinc,

More information

Learnings from residential PH design and procurement in Australia. Luc Plowman

Learnings from residential PH design and procurement in Australia. Luc Plowman Learnings from residential PH design and procurement in Australia Luc Plowman Summary Stakeholder education Expectations Materials & documentation Heating & cooling Costs Documentation requirements The

More information

Fire Safety and Performance of Wood in Multi-Residential and Commercial Buildings. Boris Iskra Forest & Wood Products Australia

Fire Safety and Performance of Wood in Multi-Residential and Commercial Buildings. Boris Iskra Forest & Wood Products Australia Fire Safety and Performance of Wood in Multi-Residential and Commercial Buildings Boris Iskra Forest & Wood Products Australia This Presentation 1. Fire Hazard Properties Building Code of Australia Volume

More information

Day Night Day Night Day Night Residential site and amphitheatre Green Non residential site boundary Red

Day Night Day Night Day Night Residential site and amphitheatre Green Non residential site boundary Red Plant Areas External plant must meet the following noise suppression requirement as adopted by the Landlord: 1. Air handling units 45db measured at 3metres from source. 2. Heat rejection plant 45db measured

More information

Insuliner. Insulation REFLECTIVE INSULATION FOR USE WHERE

Insuliner. Insulation REFLECTIVE INSULATION FOR USE WHERE Insulation A4/8 TB055G2 AW2235 Issue 8 Sep 2017 Insuliner REFLECTIVE INSULATION FOR USE WHERE it acts as the WALL OR CEILING LINING Group 2 NCC fire classification Designed for warehouses and commercial

More information

Certificate number: CM40087 Rev3

Certificate number: CM40087 Rev3 Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Certificate Holder: ABN: 22 750 783 065 19 Lowermill Rd,

More information

Insulbreak. Insulation. thermal break solution

Insulbreak. Insulation. thermal break solution Insulation A4/8 TB AW2199 Issue 8 May 2017 Insulbreak thermal break solution 3-in-1 Insulation, thermal break and vapour barrier Delivers a R0.20 thermal break solution for steel-framed construction Helps

More information

The great Aussie shed deserves great Australian insulation

The great Aussie shed deserves great Australian insulation polyair unicell The great Aussie shed deserves great Australian insulation FULLY COMPLIANT TO THE BCA Extra heavy duty Commercial grade Australian made 15 year warranty Why choose Bradford Polyair Unicell?

More information

A working acoustician s guide to compliance and the NCC(BCA)

A working acoustician s guide to compliance and the NCC(BCA) Proceedings of ACOUSTICS 2016 A working acoustician s guide to compliance and the NCC(BCA) Roger Hawkins Palmer Acoustics. (Australia) Pty Ltd, Park Ridge, Queensland, Australia ABSTRACT The Building Code

More information

Retroshield XL TM. Insulation THERMO REFLECTIVE INSULATION

Retroshield XL TM. Insulation THERMO REFLECTIVE INSULATION Insulation A4/6 TB055F AW2002 Issue 4 Sept 2015 THERMO REFLECTIVE INSULATION Innovative cross-linked closed-cell insulation core Improved Class 0 fire performance to stringent international standards 3-in-1

More information

UMWELT 75 YORK ST TERALBA. Australian Institute of Energy - Peter Jamieson. April 2014

UMWELT 75 YORK ST TERALBA. Australian Institute of Energy - Peter Jamieson. April 2014 UMWELT 75 YORK ST TERALBA Australian Institute of Energy - Peter Jamieson April 2014 Umwelt (Australia) Pty Limited AIE Presentation Locally owned 2 Directors, 3 Shareholders. Environmental consultancy

More information

Thermal comfort in a 21st century climate

Thermal comfort in a 21st century climate CIBSE Briefing Thermal comfort in a 21st century climate Addressing the impact of climate change on the built environment Summary This briefing summarises the key findings of research* commissioned by

More information

Building Code requirements for house insulation

Building Code requirements for house insulation Building Code requirements for house insulation Homes in New Zealand must have adequate insulation, so you need to make sure they have the right level of thermal resistance (R-value) for their location.

More information

VANTAGE ENERGY HIGH PERFORMANCE WINDOWS AND DOORS FOR EFFICIENCY & COMFORT

VANTAGE ENERGY HIGH PERFORMANCE WINDOWS AND DOORS FOR EFFICIENCY & COMFORT VANTAGE ENERGY HIGH PERFORMANCE WINDOWS AND DOORS FOR EFFICIENCY & COMFORT maximise efficiency & comfort WITH HIGH PERFORMANCE WINDOWS AND DOORS Australia s largest range of high performance and thermally

More information

BUILDING ENERGY EFFICIENCY CERTIFICATE

BUILDING ENERGY EFFICIENCY CERTIFICATE BUILDING ENERGY EFFICIENCY CERTIFICATE BUILDING DETAILS Building name 390 St Kilda Road Certificate no. Owner's name Building address The Trust Company (Australia) Limited 390 St Kilda Road, Melbourne,

More information

Acoustic Design Criteria

Acoustic Design Criteria Apartment Acoustics Apartment Buildings Acoustic Design Criteria Building Code of Australia: - Intertenancy walls and floors - Corridor walls and doors - Floor impact isolation - Lift, stair and core walls

More information

A GUIDE TO WINDOW AND DOOR SELECTION

A GUIDE TO WINDOW AND DOOR SELECTION Australian window association guide series A GUIDE TO WINDOW AND DOOR SELECTION An industry guide to the selection and certification of windows and doors Background Foreword As part of its commitment to

More information

Michigan Energy Code Training and Implementation Program

Michigan Energy Code Training and Implementation Program Michigan Energy Code Training and Implementation Program 1.0 Hour Advanced Program Course Number 16202 Residential Energy Plan Review School of Planning, Design & Construction Michigan State University

More information

Permicav XV TM NEXT GENERATION OF VAPOUR-PERMEABLE INSULATION FOR WALLS WITH CAVITIES

Permicav XV TM NEXT GENERATION OF VAPOUR-PERMEABLE INSULATION FOR WALLS WITH CAVITIES Insulation A4/8 PS055XV AW2244 Issue 5 Oct 2017 Permicav XV TM NEXT GENERATION OF VAPOUR-PERMEABLE INSULATION FOR WALLS WITH CAVITIES 5x higher vapour transmission than previous generation Reduces the

More information

Australian Standard. Thermal insulation of dwellings Bulk insulation Installation requirements AS

Australian Standard. Thermal insulation of dwellings Bulk insulation Installation requirements AS AS 3999 1992 Australian Standard Thermal insulation of dwellings Bulk insulation Installation requirements This Australian Standard was prepared by Committee BD/58, Thermal performance and Insulation of

More information

Brick Veneer Walls. Insulation

Brick Veneer Walls. Insulation Insulation A4/8 BV AW2157 Issue 7 Nov 2016 Brick Veneer Walls Insulation guide Helps achieve a 6-star house energy rating Rigid Kingspan Kooltherm and flexible Kingspan AIR-CELL solutions available Fibre-free,

More information

Garage Conversions. Technical Issues

Garage Conversions. Technical Issues Garage Conversions Introduction: if you need more space and you do not want to move house you may wish to consider converting your garage. Your home is probably your most valuable asset so it is important

More information

ADMINISTRATION CHAPTER 1

ADMINISTRATION CHAPTER 1 CHAPTER 1 ADMINISTRATION PART 1 SCOPE AND APPLICATION SECTION 101 SCOPE AND GENERAL REQUIREMENTS 101.1 Title. This code shall be known as the Florida Building Code, Energy Conservation, and shall be cited

More information

AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW.

AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW. AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW www.stromatech.com AIR BARRIER DESIGN PRINCIPLES Building Regulations Approved Document Parts L1A & L2A currently requires that new buildings have to achieve a

More information

BUILDING ENERGY EFFICIENCY CERTIFICATE

BUILDING ENERGY EFFICIENCY CERTIFICATE BUILDING ENERGY EFFICIENCY CERTIFICATE BUILDING DETAILS Building name BEEC Example Building Certificate no. Owner's name Example Company Name Issue date 6/10/2011 Building address 123 ANYWHERE STREET BRISBANE

More information

Warmer Roof. Transforming conservatory roofs. WarmerRoof

Warmer Roof. Transforming conservatory roofs. WarmerRoof Warmer Roof Transforming conservatory roofs WarmerRoof the easy way to transform your conservatory into a room you can use and enjoy all year round WarmerRoof what is the Warmer Roof? a highly insulated,

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 4859.1:2002 (Incorporating Amendment No. 1) AS/NZS 4859.1:2002 Australian/New Zealand Standard Materials for the thermal insulation of buildings Part 1: General criteria and technical provisions

More information

IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST

IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST ENVELOPE REQUIREMENTS Project: Date: Instructions RECOMMENDED: List performance values, note exceptions that were applied, or provide other

More information

REFLECTIVE TECHNOLOGY CONSTRUCTION MEMBRANES

REFLECTIVE TECHNOLOGY CONSTRUCTION MEMBRANES CI/SfB (47) Ln6 Uniclass Pr_25_57_10_68 January 2018 REFLECTIVE TECHNOLOGY CONSTRUCTION MEMBRANES................................ ........................................................ REFLECTIVE TECHNOLOGY

More information

BC BUILDING CODE ERRATA

BC BUILDING CODE ERRATA BC BUILDING CODE ERRATA The following changes should be made to print and offline copies of the 2012 BC Codes. The 2012 BC Codes subscription products include these changes. Highlighted text is used in

More information

NEW FOUR STORY MIXED USE RESTAURANT, RETAIL, LODGING, AND OFFICE BUILDING OWNER S PROJECT REQUIREMENTS

NEW FOUR STORY MIXED USE RESTAURANT, RETAIL, LODGING, AND OFFICE BUILDING OWNER S PROJECT REQUIREMENTS NEW FOUR STORY MIXED USE RESTAURANT, RETAIL, LODGING, AND OFFICE BUILDING OWNER S PROJECT REQUIREMENTS TABLE OF CONTENTS Introduction Page 2 Project Description Page 2 Owner s Directives Page 4 Design

More information

Double Brick Cavity Walls

Double Brick Cavity Walls Insulation A4/6 DB AW1638 Issue 3 Feb 2014 Double Brick Cavity Walls Insulation guide Helps achieve a 6-star house energy rating Rigid Kingspan Kooltherm and flexible Kingspan AIR-CELL solutions available

More information

Boulder City NV Prepared by (Print Name) Signature Date

Boulder City NV Prepared by (Print Name) Signature Date City of Boulder City Community Development Department Building & Safety Division 401 California Avenue Boulder City, NV 89005-2600 702-293-9282 (Main Line) 702-293-9392 (Fax) 2009 International Energy

More information

Timber in Bushfire Prone Areas

Timber in Bushfire Prone Areas In many parts of Australia, the construction of new buildings and additions to existing buildings will be assessed as being in a Bushfire-prone Area. The relevant Australian Standard AS 959 provides six

More information

CB04. Outback House. Case Study. Creative Spaces Australia. by Casey Brown Architecture

CB04. Outback House. Case Study. Creative Spaces Australia. by Casey Brown Architecture CB04 Case Study Outback House by Casey Brown Architecture Creative Spaces Australia E : info@creativespacesaustralia.com.au www.creativespacesaustralia.com.au Introduction Inspired by the big sheds of

More information

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition Spray Polyurethane Foam Design Guidance Insulation and Air Barrier Requirements of the 2012 I-Codes Spray Foam Coalition about the collaboration the center for the polyurathanes industry (CPI) of the

More information

Fire protecting windows close to boundaries

Fire protecting windows close to boundaries Fire protecting windows close to boundaries product solutions Q1 Queensland Hyundai Head Office Sydney Digital Life Labs Melbourne ANZ Head Office Melbourne Stockhome, Stocklands HQ Sydney T: 1300 655

More information

Training Certification Categories

Training Certification Categories Training Certification Categories Residential Residential Building Inspector structures are free from hazardous structural conditions and comply with the UCC. Duties include inspection of footings and

More information

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis Senior Design Project for UNO Design of the International Studies Building: An Environmental Analysis Design Intent Implement Passive & Active design strategies in order to make the building: More Energy

More information

SOL UTIONS LIVING SOLUTIONS LIVING SOLUTIONS

SOL UTIONS LIVING SOLUTIONS LIVING SOLUTIONS Buyer s Guide HOMES 1300 985 110 LIVING SUPPORT SOLUTIONS 2 BCDS0868 Contents Just imagine the space you can create 4 More reasons to choose SmartSpace 8 SmartSpace Project Planner 9 Design your SmartSpace

More information

Project Description. Projected build start date 01 Mar 2010 Projected date of occupation 31 May Aberdare, Rhondda Cynon Taff, Wales

Project Description. Projected build start date 01 Mar 2010 Projected date of occupation 31 May Aberdare, Rhondda Cynon Taff, Wales http://lowenergybuildings.org.uk Project name Self Heating Social Housing- the zero carbon retrofit Project summary The target for this project is to create the first UK PassivHaus retrofit using low/zero

More information

PALM TREE RESIDENTIAL AREA / Hanoi, Vietnam

PALM TREE RESIDENTIAL AREA / Hanoi, Vietnam PALM TREE RESIDENTIAL AREA / Hanoi, Vietnam Vietnam Please insert a general picture of the project Geocoordinates Latitude Longitude Nouth East 21 1'42''N 105 51'12''E BUILDING FEATURES Construction type

More information

Passive House Object Documentation

Passive House Object Documentation Passive House Object Documentation Detached house with 4no. Bedrooms in Crawsfordsburn, Northern Ireland. Project Designer Mr Paul McAlister Paul McAlister Architects Ltd Year of construction 2012/2013

More information

Design. Boral CinemaZone Fact Sheet. Windows. Acoustic sealants. Sound absorptive panels. Ventilation. Floor coverings. The vision.

Design. Boral CinemaZone Fact Sheet. Windows. Acoustic sealants. Sound absorptive panels. Ventilation. Floor coverings. The vision. Windows Like doorways, windows can be a significant source of sound leakage. For maximum isolation, windows should either be removed or built over internally - leaving the house facade unaffected. If natural

More information

CI/Sfb (2 ) Rn7 M2 Fourth Issue June Product Selector INSULATION FOR ROOFS, WALLS & FLOORS. Low Energy Low Carbon Buildings

CI/Sfb (2 ) Rn7 M2 Fourth Issue June Product Selector INSULATION FOR ROOFS, WALLS & FLOORS. Low Energy Low Carbon Buildings Insulation CI/Sfb (2 ) Rn7 M2 Fourth Issue June 2011 Product Selector INSULATION FOR ROOFS, WALLS & FLOORS Visit our brand new website: www.kingspaninsulation.co.uk Low Energy Low Carbon Buildings Kingspan

More information

Airspace R-Values. Educational Overview. Revised 12/6/2016

Airspace R-Values. Educational Overview. Revised 12/6/2016 Airspace R-Values Educational Overview Revised 12/6/2016 Introduction Airspaces contained within building envelope assemblies are known to contribute to thermal performance. But, the actual R-value for

More information

Multi-layer Insulation Blanket for Walls

Multi-layer Insulation Blanket for Walls Multilayer Insulation Blanket for Walls Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 High performance wall insulation Full Agrément certification

More information

Interpretation Variables and Common Areas of Confusion. Of the 2009 IECC

Interpretation Variables and Common Areas of Confusion. Of the 2009 IECC Interpretation Variables and Common Areas of Confusion Of the 2009 IECC 1. (Mandatory) provisions vs. (Prescriptive) provisions: The IECC contains flexibility by allowing different approaches to achieve

More information

DTS & ENERGY MODELLING PROTOCOL GUIDE Version 1.0

DTS & ENERGY MODELLING PROTOCOL GUIDE Version 1.0 DTS & ENERGY MODELLING PROTOCOL GUIDE Version 1.0 Green Star SA Multi Unit Residential v1 DTS & Energy Modelling Protocol Guide First Released: 27 th October 2011 Last Update: 27 th October 2011 Change

More information

Using On-site Renewable and Reclaimed Energy Sources. Handbook. NoN-MaNdatory document

Using On-site Renewable and Reclaimed Energy Sources. Handbook. NoN-MaNdatory document Using On-site Renewable and Reclaimed Energy Sources 2011 Handbook NoN-MaNdatory document USING ON-SITE RENEWABLE AND RECLAIMED ENERGY SOURCES INFORMATION HANDBOOK 2011 Important Notice and Disclaimer

More information

Thermal Characteristics of Single-Family Detached, Single-Family Attached, Low-Rise Multifamily, and Mobile Homes

Thermal Characteristics of Single-Family Detached, Single-Family Attached, Low-Rise Multifamily, and Mobile Homes Appendix B Thermal Characteristics of Single-Family Detached, Single-Family Attached, Low-Rise Multifamily, and Mobile Homes 1975-76 by the National Association of Home Builders Research Foundation, Inc.,

More information

Fire Engineering, the BCA (NCC) & Bushfire Calculator. Keith Nicholls - Manager Product Testing and Assessments (Australia) Exova Group Limited

Fire Engineering, the BCA (NCC) & Bushfire Calculator. Keith Nicholls - Manager Product Testing and Assessments (Australia) Exova Group Limited Fire Engineering, the BCA (NCC) & Bushfire Calculator Keith Nicholls - Manager Product Testing and Assessments (Australia) Exova Group Limited Presentation Topics Current Building Code (fire safety) design

More information

Building Regulations Part L1A (2006)

Building Regulations Part L1A (2006) PART L1A GUIDE ENGLAND & WALES MAY 2006 High performance insulation for new mixed development housing Building Regulations Part L1A (2006) COST EFFECTIVE THERMAL SOLUTIONS House Type A House Type B House

More information

Evaluation of Energy Savings of the New Chinese Commercial Building Energy Standard

Evaluation of Energy Savings of the New Chinese Commercial Building Energy Standard Evaluation of Energy Savings of the New Chinese Commercial Building Energy Standard Wei Feng, Ke Huang, Mark Levine and Nan Zhou, Lawrence Berkeley National Laboratory Shicong Zhang, Lawrence Berkeley

More information

Construction Studies Theory - Higher Level

Construction Studies Theory - Higher Level 2015. M76 Coimisiún na Scrúduithe Stáit State Examinations Commission Leaving Certificate Examination, 2015 Construction Studies Theory - Higher Level (300 marks) Friday, 12 June Afternoon, 2:00 to 5:00

More information

November 10, 2015 Baltimore, MD. presented by

November 10, 2015 Baltimore, MD. presented by Baltimore, MD 2015 I code R values and best practices presented by Mark S. Graham Associate Executive Director, Technical Services National Roofing Contractors Association (NRCA) 1 IBC 2015: Ch. 15: Roofing

More information

William Stanwix and Alex Sparrow. The. Hempcrete. Book Designing and building with hemp-lime. sample pages to show book layout and design only

William Stanwix and Alex Sparrow. The. Hempcrete. Book Designing and building with hemp-lime. sample pages to show book layout and design only William Stanwix and Alex Sparrow The Hempcrete Book Designing and building with hemp-lime sample pages to show book layout and design only 2 The Hempcrete Book Contents Foreword by Professor Tom Woolley...

More information

Energy Simulation Tool Approval Technical Assistance Manual 2017 Florida Building Code, Energy Conservation

Energy Simulation Tool Approval Technical Assistance Manual 2017 Florida Building Code, Energy Conservation Energy Simulation Tool Approval Technical Assistance Manual 2017 Florida Building Code, Energy Conservation Prepared by: Florida Solar Energy Center 1679 Clearlake Road, Cocoa FL 32922. www.fsec.ucf.edu

More information

Report for CSR Hebel. Impact of various wall and floor construction options on 5 star compliance for two houses. by Tony Isaacs Consulting Pty Ltd

Report for CSR Hebel. Impact of various wall and floor construction options on 5 star compliance for two houses. by Tony Isaacs Consulting Pty Ltd Tony Isaacs Consulting Pty Ltd Sustainable Buildings Specialist Report for CSR Hebel Impact of various wall and floor construction options on 5 star compliance for two houses by Tony Isaacs Consulting

More information

SECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation.

SECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation. SECTION B Steel Frame Wall Systems. Contents. SUBJECT Steel Stud Selection Tables Introduction Design Considerations Installation Components PAGE B2 B4 B4 B6 B7 System Specifications Single Stud Staggered

More information

Passivhaus Project Documentation Wrexham Passivhaus

Passivhaus Project Documentation Wrexham Passivhaus Passivhaus Project Documentation Wrexham Passivhaus Design/Architecture: Simmonds Mills Architects Structural ngineer: Bob Johnson Structural ngineers, Shrewsbury Building Services: Alan Clarke Passivhaus

More information

Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments

Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments Use of these instructions with a residential data collection

More information

SAFEBRIDGE HIGH PERFORMANCE ROOF INSULATION SYSTEM

SAFEBRIDGE HIGH PERFORMANCE ROOF INSULATION SYSTEM SAFEBRIDGE HIGH PERFORMANCE ROOF INSULATION SYSTEM Safebridge Key Benefits Creates a safer roof environment for workers during construction Code compliant with BCA/NCC Section J Uses the purlin space without

More information

June Residential Refurbishment Separating walls

June Residential Refurbishment Separating walls June 2010 Residential Refurbishment 3.6.1 Separating walls Residential refurbishment 3.0 Residential Refurbishment Separating Walls Contents Introduction find online page Solution optimiser and pathfinder

More information

Passivhaus Projects and Benefits

Passivhaus Projects and Benefits Passivhaus Projects and Benefits Andrew T. Arthur MPH CMCIEH Arthur Associates Passivhaus not Passive House Need to make distinction between: this and this Passivhaus Standard which was developed in Germany

More information

CI/SfB. November Design Guide Concrete block masonry

CI/SfB. November Design Guide Concrete block masonry CI/SfB November 1997 Ff Design Guide Concrete block masonry Design Guide concrete block masonry This Topblock Design Guide contains detailed information on the design and performance of constructions using

More information

Carpenter Level 2 Rev. September 2017

Carpenter Level 2 Rev. September 2017 Level 2 A5 Site Layout II Duration: 14 hours 7 hours 7 hours Upon completion of this unit the apprentice will demonstrate knowledge of site layout tools and equipment and their applications and procedures

More information

3.1 Noise Overlay District

3.1 Noise Overlay District 3.1 A. Purpose The purpose of this District is to establish a Noise Overlay Zoning District within the. B. Special Definitions As used in this Article only, the following terms shall be defined as set

More information

CALGREEN NON-RESIDENTIAL BUILDING Checklist

CALGREEN NON-RESIDENTIAL BUILDING Checklist CALGREEN NON-RESIDENTIAL BUILDING Checklist REVISED 11/18/14 New non-residential buildings shall be designed to include the green building mandatory measures specified in this checklist. This checklist

More information

GypLyner UNIVERSAL Metal framed wall lining system

GypLyner UNIVERSAL Metal framed wall lining system Metal framed wall lining system Pizza Express, York 30 Metal framed wall lining system wall lining system is a cost-effective, virtually independent metal frame drylining. It is a general purpose system

More information

Chapter 1: Compliance

Chapter 1: Compliance Chapter 1: Compliance [101] Who Must Comply? All new residential construction must comply with the Washington State Energy Code (WSEC). Exceptions. Exempt from envelope requirements but needing to comply

More information

2012 CLEAResult All rights reserved. Residential Energy Efficiency

2012 CLEAResult All rights reserved. Residential Energy Efficiency Residential Energy Efficiency Presenter Bio Jaymar Davis, PE, CEM, CLEP, CMVP, CEA Sr. Field Engineering Manager 10 Years experience in energy efficiency Johnson Controls, Kohler Co. Certifications: Licensed

More information

White Paper ENVELOPE-FIRST APPROACH TO NET-ZERO ENERGY BUILDINGS

White Paper ENVELOPE-FIRST APPROACH TO NET-ZERO ENERGY BUILDINGS BOULDER CHICAGO NASHVILLE SALT LAKE CITY SAN FRANCISCO SPRINGFIELD, MO WASHINGTON, DC 2540 Frontier Avenue, Suite 100 Boulder, Colorado 80301 303.444.4149 White Paper ENVELOPE-FIRST APPROACH TO NET-ZERO

More information

reflective technology

reflective technology 05 / 4210 reflective technology 06/05 to create thermal efficiency Why did regulation change? With the Government s commitment to the Kyoto Agreement, there have been more stringent requirements to reduce

More information

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other This information must be on the drawing documents not attached to plans. The following Compliance statements must be on the drawings: 2009 International Energy Conservation Code Statement of acknowledgement

More information

Stadtwerke Konstanz Customer Centre, Constance

Stadtwerke Konstanz Customer Centre, Constance Concepts Products Service Stadtwerke Konstanz Customer Centre, Constance 1 Project Report Stadtwerke Konstanz Customer Centre, Constance In summer 2010, we were commissioned to build a new innovative customer

More information

ENERGY EFFICIENT RETROFIT MEASURES GUIDE

ENERGY EFFICIENT RETROFIT MEASURES GUIDE ENERGY EFFICIENT RETROFIT MEASURES GUIDE ENERGY EFFICIENCY RETROFIT PROGRAM FOR LOW-INCOME HOUSEHOLDS CO-OP COMPONENT For nonprofit continuing housing cooperatives listed in the Québec Enterprise Register

More information

Green Building Guideline of Jordan

Green Building Guideline of Jordan Green Building Guideline of Jordan T. Awadallah 1*, S. Habet 1, A. Mahasneh 1, H. Adas 2 1 Royal Scintific Society, Amman, Jordan 2 National Energy Research Center, Amman, Jordan * Corresponding author.

More information

CONSTRUCTION & BUILDING SERVICES ADVANCED AND HIGHER APPRENTICESHIPS

CONSTRUCTION & BUILDING SERVICES ADVANCED AND HIGHER APPRENTICESHIPS CONSTRUCTION & BUILDING SERVICES ADVANCED HIGHER APPRENTICESHIPS WHY CHOOSE US? ESTABLISHED & NEW We are an established Further Education College, located in the heart of Coventry. We recently merged City

More information

GREENHOUSE, MIXED USE DEVELOPMENT LEEDS WEST AND MACHELL ARCHITECTS

GREENHOUSE, MIXED USE DEVELOPMENT LEEDS WEST AND MACHELL ARCHITECTS Project data Name of Project Greenhouse, Leeds Name of client Citu Main contractor Clegg Construction Quantity surveyor Sum Structural engineer Thomasons Services engineer Woods Environmental Procurement

More information

Fabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Upstand KS1000 DLU

Fabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Upstand KS1000 DLU Fabrications, Safety & Lighting Solutions Kingspan Day-Lite KS1000 DLU Applications Kingspan Day-Lite is a factory-assembled polycarbonate upstand rooflight integrated into an insulated roof panel, which

More information

Sapporo Net-Zero Energy Home Hokkaido, Japan. Description. Setting. Super E Canadian Member. Super E Japanese Member. Super E Case Study

Sapporo Net-Zero Energy Home Hokkaido, Japan. Description. Setting. Super E Canadian Member. Super E Japanese Member. Super E Case Study Sapporo Net-Zero Energy Home Hokkaido, Japan Description The first Super E net-zero energy house was built by the oldest Super E partnership. Tsuchiya Two-by and K. Ito and Associates constructed the very

More information

Building Air Tightness: Consultation Paper. Building Air Tightness Consultation Paper

Building Air Tightness: Consultation Paper. Building Air Tightness Consultation Paper Building Air Tightness Consultation Paper 1 Instructions We are seeking your written feedback on the proposed updates to Green Star Design & As Built and Green Star - Interiors. Your feedback is important

More information

RELIANCE HOUSE 20 WATER STREET LIVERPOOL L2 8UQ

RELIANCE HOUSE 20 WATER STREET LIVERPOOL L2 8UQ RELIANCE HOUSE 20 WATER STREET LIVERPOOL L2 8UQ EXTENSION & CONVERSION PROJECT TO CREATE 139 APARTMENTS INVESTORS REPORT 01 22 nd NOVEMBER 2017 Prepared By: G.Moody BSc Hons MRICS C.Build E MCABE Ref:

More information

DESIGNING FOR PODS MANUAL

DESIGNING FOR PODS MANUAL DESIGNING FOR PODS MANUAL www.interpod.com 1300 00 PODS 1 TABLE OF CONTENTS 6 6 7 8 9 10 11 12 13 13 13 13 13 13 14 16 18 18 18 19 19 19 CUSTOM BATHROOM DESIGN Design Types & Pod Quantities Size & Shape

More information

Multi-layer Insulation Blanket for Walls

Multi-layer Insulation Blanket for Walls Multilayer Insulation Blanket for Walls Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 High performance wall insulation Full Agrément certification

More information

Project Description. Projected build start date 24 Dec 2004 Projected date of occupation. Energy target. Existing external wall construction

Project Description. Projected build start date 24 Dec 2004 Projected date of occupation. Energy target. Existing external wall construction http://lowenergybuildings.org.uk Project name Withy Cottage Project summary Timber Frame & Straw Bale self build with thermal bridge free construction (other than door and window frames). Simple flat raft

More information

Kingspan Day-Lite Kapture Data Sheet

Kingspan Day-Lite Kapture Data Sheet Light + Air UK & Republic of Ireland Kingspan Day-Lite Data Sheet KS700DLK, KS1400DLK, KS0DLK 2 Kingspan Day-Lite KS700DLK, KS1400DLK, KS0DLK Application KS700DLK, KS1400DLK, KS0DLK & KS2750DLK rooflights

More information

RESEARCH HIGHLIGHT. Design Development of Low-Energy and Affordable Multi-Unit Residential Buildings

RESEARCH HIGHLIGHT. Design Development of Low-Energy and Affordable Multi-Unit Residential Buildings RESEARCH HIGHLIGHT Design Development of Low-Energy and Affordable Multi-Unit Residential Buildings Case study: Bois Ellen Co-operative Residence, Laval, Quebec April 2016 Technical Series INTRODUCTION

More information

ADVISORY NOTE Fire Performance of External Walls and Cladding Application

ADVISORY NOTE Fire Performance of External Walls and Cladding Application ADVISORY NOTE 2016-3 Fire Performance of External Walls and Cladding Application NCC Volume: Section/Part: One Various Date first issued: August 2016 Date revised: September 2016 Copyright and licence

More information

IECC Commercial Significant Changes Summary Tier I

IECC Commercial Significant Changes Summary Tier I 2009-2015 IECC Commercial Significant Changes Summary Tier I The first change is in the layout of the book. Instead of having Chapters 1-3 that applied to all projects and then having Chapter 4 Residential

More information