1 VENT CAP (MUSHROOM TYPE) SOLID CAP EXIST GRADE MIN BUILDING REFER TO NOTE #4 MIN CONCRETE SIDEWALK CURB OR EDGE OF SIDEWALK STREET CLEANOUT (REFER TO NOTE #3) VENT PIPE 4" PVC 6" PVC CLEANOUT CONCRETE ALL AROUND VENT PIPE 4" PVC 4" PVC WYE 4" PVC YARD TRAP LOCATION TO BE FIELD LOCATED 6" PVC WYE REFER TO NOTE #2 4" LATERAL 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR ONE PIPE LENGTH MAX (REFER TO NOTE #1) 4"x6" INCREASER WYE BRANCH SEWER LINE RIGHT-OF-WAY/ PROPERTY LINE REFER TO TYPICAL EXCAVATION, BACKFILL & PIPE EMBEDMENT DETAIL 40'-0" (MAX) RECOMMENDED 1 4" SINGLE RUNNING TRAP WILL BE INSTALLED WITHIN ONE PIPE LENGTH OF THE END OF THE 6" LATERAL 2 MINIMUM DEPTH OF 4" LATERAL WILL BE 48" BELOW FINISHED GRADE UNLESS APPROVED BY TOWNSHIP ENGINEER 3 IF THERE IS NOT A CLEANOUT LOCATED INSIDE OF DWELLING AN ADDITIONAL CLEANOUT SHALL BE INSTALLED IMMEDIATELY OUTSIDE OF THE BUILDING PRIOR TO RUNNING TRAP 4 LOCATE VENT CAP AND CLEANOUT IN LAWN AREA MUSHROOM CAP SHALL BE USED ON VENT 5 IN GENERAL, SANITARY SEWERS SHOULD BE LOCATED AT LEAST 100 FEET FROM PUBLIC WATER SUPPLY SOURCES AND 50 FEET FROM PRIVATE WATER SUPPLY SOURCES, UNLESS THE SANITARY LINES ARE ENCASED IN CONCRETE OR APPROVED EQUIVALENT TYPICAL BUILDING SEWER

2 SEWER MAIN 1 1/4" FULL PORT BALL CORPORATION STOP 1 1/4" SERVICE LATERAL 1 1/4" FULL PORT BALL CURB STOP W/CURB BOX RIGHT-OF-WAY LINE CHECK VALVE MATERIAL: GLASS FILLED PVC GRINDER PUMP STATION 4" PVC TO DWELLING 4'-0" MIN COVER GRADE MOUNT CONTROL PANEL TO EXTERIOR GRINDER PUMP STATION LID ASSEMBLY WITH PENTAGON HEAD PLUG MATERIAL: CAST IRON WITH ASPHALT-BASE PAINT LABELED "SEWER" 6" MIN AFG 4'-0" TO 5'-0" 220V/1Ø/20 AMP, OR 120V/1Ø/30 AMP POWER FROM HOME TO CONTROL PANEL BY HOME OWNER 1 1/4" CONDUIT 1 1/4" FULL PORT BALL CORPORATION STOP CHECK VALVE 15'-0" MAX BASEMENT MIN 2'-0" OVER ELECTRIC CABLE 1 1/4" SERVICE LATERAL SUBGRADE SADDLE TAP SEWER MAIN 4'-0" MIN COVER SUBGRADE 1 1/4" FULL PORT BALL CURB STOP 4" MIN COMPACTED 2A AGGREGATE CONCRETE 4" PVC TESTED WATER TIGHT 4" MIN COMPACTED 2A AGGREGATE

3 FINAL BACKFILL PROPOSED PIPE EXIST SOIL MIN MIN INITIAL BACKFILL HAUNCHING AASHTO M43 GRADUATION NO 7 OR NO 8 MATERIAL SHALL MEET THE REQUIREMENTS OF PUBLICATION 408, SECTION 703 6" BEDDING TYPICAL EXCAVATION, BACKFILL & PIPE EMBEDMENT DETAIL

4 GRADE 4'-0" MINIMUM EXIST WATER MAIN UNDISTURBED EARTH IF LESS THAN 10'-0" MAINTAIN 18" MIN NEW SEWER LINE NEW SEWER LINE PARALLEL TO EXISTING WATER MAIN DETAIL

5 UNDISTURBED EARTH SEWER LINE MIN BARREL OF PIPE BELL OF PIPE "A" 8" OD 8" TRENCH WIDTH PIPE SIZE 4" - 16" 18" - 48" 54" - 84" "A" 6" 6" 10" NOTE: ALL CONCRETE SHALL HAVE MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI AT THE END OF 28 DAYS CONCRETE ENCASEMENT DETAIL

6 GRADE 10'-0" EQUAL DISTANCE EQUAL DISTANCE MIN 18" MIN 4'-0" MECHANICAL JOINTS REQUIRED NEW SEWER LINE REFER TO DETAIL S-6 EXISTING WATER MAIN WHEN VERTICAL SEPARATION IS LESS THAN 18" PROVIDE CONCRETE ENCASEMENT ON UNDISTURBED GROUND THE LENGTH OF THE ENCASEMENT SHALL BE EXTENDED A MINIMUM OF 10 FEET BEYOND THE CENTERLINE OF THE WATER MAIN IN BOTH DIRECTIONS NOTE: ALL CONCRETE SHALL HAVE MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT THE END OF 28 DAYS NEW SEWER LINE CROSSING UNDER EXISTING WATER MAIN DETAIL

7 GRADE EQUAL 10'-0" EQUAL WHEN VERTICAL SEPARATION IS LESS THAN 18" PROVIDE CONCRETE ENCASEMENT ON UNDISTURBED GROUND THE LENGTH OF THE ENCASEMENT SHALL BE EXTENDED A MINIMUM OF 10 FEET BEYOND THE CENTERLINE OF THE WATER MAIN IN BOTH DIRECTIONS DISTANCE DISTANCE 4'-0" MINIMUM REFER TO DETAIL S-6 MIN 18" MECHANICAL JOINTS REQUIRED NEW SEWER LINE EXIST WATER MAIN POLYETHYLENE ENCASEMENT NOTE: ALL CONCRETE SHALL HAVE MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT THE END OF 28 DAYS NEW SEWER LINE CROSSING OVER EXISTING WATER MAIN DETAIL

8 REFER TO FRAME AND COVER DETAIL PRECAST CONCRETE GRADE RINGS (VARIES, MIN 6", MAX ) 24"x48" ADAPTOR 8" O-RING JOINT PREFORMED PLASTIC SEALING COMPOUND: FS SS-S-210A, TYPE 1, ROPE FORM HEAT SHRINKABLE SHEET MANHOLE EXTERIOR TO BE COATED WITH BITUMASTIC SEALANT VARIES 48" RISERS 5" 48" INSIDE POLYPROPYLENE MANHOLE OC WITH CAST IN PRECAST BASE 6" CHANNEL MAX 6" MIN COMPACTED PennDOT 2A MODIFIED ON UNDISTURBED SUBGRADE 9" 1 ALL PIPE TO MANHOLE CONNECTIONS SHALL BE MADE WITH A CAST-IN-PLACE GASKET (A-LOK OR APPROVED EQUAL) 2 MANHOLES EXCEEDING A DEPTH OF 16 FEET SHALL PROVIDE PRE-CAST LANDING PLATFORM TYPICAL MANHOLE DETAIL

9 FRAME LETTERS TO BE 2" HIGH MIN 4-1"Ø CORED OR DRILLED HOLES ON 32" BOLT CIRCLE AS SHOWN LIFTING RING (TYP 2 PLACES) 3/8" 3/8" 1/2" 5/8" 3 1/8" 3/16" PICK HOLE (TYP 2 PLACES) PICK HOLE DETAIL "O-RING" GASKET PLAN 1 3/4" 1 3/8" 3 1/8" 24" 23 3/4" (TOP) 23 5/8" (BOTTOM) 3/4" 3/4" 1/8" NON-SKID LUGS 3 1/8" 7" -9" 1" 3" 5/8" 7/8" 5" 24 1/2" 3/4" SECTION LIFT RING DETAILS NOTE: APPROXIMATE WEIGHT 500# CAST IRON REGULAR MANHOLE FRAME & COVER

10 SEMI-CIRCULAR CHANNELS AND FLOOR TO BE SMOOTH DIA 48" PRECAST CONCRETE MANHOLE SECTIONS MANHOLE BASE TYPICAL CHANNEL CONFIGURATION 1 ALL FLOW CHANNELS SHALL BE PRE-CAST BY MANUFACTURER UNLESS AUTHORIZED BY AUTHORITY

11 INFLUENT 45 CUT PVC PIPE TO PROVIDE SPLASH GUARD VARIES PVC PIPE DIA EQUALS INFLUENT PIPE DIA PLUS 2" STAINLESS STEEL BANDS 48" OC CHANNEL TYPICAL INSIDE DROP MANHOLE DETAIL

PERMANENT PAVEMENT REPAIR NO SCALE

PERMANENT PAVEMENT REPAIR NO SCALE SAWCUT EXISTING PAVEMENT 2" BITUMINOUS CONCRETE SURFACE COURSE, CLASS 2 (MIN) CLEAN EDGE PRIOR TO PAVING AND PAINT WITH LIQUID BITUMEN. INSTALL SEALANT OVER JOINT UPON COMPLETION 2" BITUMINOUS CONCRETE

More information

STANDARD CONSTRUCTION DETAILS SANITARY SEWER REVISED MARCH 2018 DEPARTMENT OF ENGINEERING

STANDARD CONSTRUCTION DETAILS SANITARY SEWER REVISED MARCH 2018 DEPARTMENT OF ENGINEERING STANDARD CONSTRUCTION DETAILS REVISED MARCH 2018 GENERAL NOTES EMBEDMENT DETAILS EMBEDMENT DETAILS TWO-WAY CLEANOUT - EXISTING LATERAL TWO-WAY CLEANOUT - NEW CONSTRUCTION TYPICAL SEWER HOUSE SERVICE CONNECTION

More information

SANITARY MANHOLE S-1 ENGINEERING DEPARTMENT PLATE NUMBER NEENAH R-1733 CASTING ASSEMBLY OR AS NOTED ON PLAN OR APPROVED EQUAL.

SANITARY MANHOLE S-1 ENGINEERING DEPARTMENT PLATE NUMBER NEENAH R-1733 CASTING ASSEMBLY OR AS NOTED ON PLAN OR APPROVED EQUAL. "INFI-SHIELD" SEAL OR EQUAL. NEENAH R-1733 CASTING ASSEMBLY OR AS NOTED ON PLAN OR APPROVED EQUAL. 27" HDPE ADJUSTING RINGS (2 MIN., 1' MAX. OF RINGS). ECCENTRIC CONE 4.0' HIGH 48" 5" P2 PROFILE GASKET

More information

TOWN OF HOLLY SPRINGS ENGINEERING DEPARTMENT

TOWN OF HOLLY SPRINGS ENGINEERING DEPARTMENT COMPACTED BACK FILL COMPACTED BACK FILL UNDISTURBED TRENCH WALL INITIAL BACKFILL SPRING LINE OF PIPE HAUNCHING EMBEDMENT MATERIAL SPRING LINE OF PIPE HAUNCHING EMBEDMENT MATERIAL MIN. BEDDING BEDDING MINIMUM

More information

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections.

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections. SANITARY SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Sanitary Sewer Gravity Mains B. Sanitary Sewer Force Mains C. Sanitary Sewer Services 1.02 DESCRIPTION OF WORK A. Construct sanitary sewer gravity

More information

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections.

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections. SANITARY SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Sanitary Sewer Gravity Mains B. Sanitary Sewer Force Mains C. Sanitary Sewer Services 1.02 DESCRIPTION OF WORK A. Construct sanitary sewer gravity

More information

FOX METRO WATER RECLAMATION DISTRICT MANHOLE / SEWER PIPE MATERIALS AND INSTALLATION SPECIFICATIONS MATERIALS 1. PIPE & FITTINGS

FOX METRO WATER RECLAMATION DISTRICT MANHOLE / SEWER PIPE MATERIALS AND INSTALLATION SPECIFICATIONS MATERIALS 1. PIPE & FITTINGS FOX METRO WATER RECLAMATION DISTRICT MANHOLE / SEWER PIPE MATERIALS AND INSTALLATION SPECIFICATIONS MATERIALS 1. PIPE & FITTINGS Rev: 3/26/18 Pipe and fittings used in sanitary sewer construction shall

More information

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems.

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems. SECTION 33 05 13 MANHOLES AND STRUCTURES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems. B. Related Sections: 1. Section 03 20 00 - Concrete

More information

SECTION PRECAST CONCRETE MANHOLES

SECTION PRECAST CONCRETE MANHOLES SECTION 02601 PRECAST CONCRETE MANHOLES PART 1 GENERAL 1.1 The work specified in this section shall include the furnishing, hauling, and placing of all precast manholes shown on the drawings and as specified

More information

HITT STREET UNIVERSITY PROJECT #: CP REFER TO CP PLANS FOR ELECTRICAL DUCTBANK IN HITT STREET INSTALL:

HITT STREET UNIVERSITY PROJECT #: CP REFER TO CP PLANS FOR ELECTRICAL DUCTBANK IN HITT STREET INSTALL: N 1133521.33 E 1689742.43 STA: 10+53.07 INSTALL: 2-10" 90 BENDS CONNECT TO MIDDLEBUSH HALL INTERIOR PLANT PLUMBING MIDDLEBUSH HALL HW1 HWS HWR 10+00 FREDRICK APARTMENTS FINE ARTS INSTALL 422 LF 10" HWS

More information

SECTION D2 MANHOLES AND CATCH BASINS GENERAL MATERIALS

SECTION D2 MANHOLES AND CATCH BASINS GENERAL MATERIALS SECTION D2 MANHOLES AND CATCH BASINS GENERAL This section covers the installation of new manholes, catch basins, drop inlets, drywall structures and the installation of hoods in existing catch basins.

More information

SECTION SANITARY UTILITY SEWERAGE PIPING

SECTION SANITARY UTILITY SEWERAGE PIPING SECTION 33 31 00 SANITARY UTILITY SEWERAGE PIPING PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Sanitary sewer pipe and fittings. 2. Underground pipe markers. 3. Connection to existing manholes. 4.

More information

SECTION A-A NTS. Figure 4.1 Alternative Flow Dispersal Trench NOTES:

SECTION A-A NTS. Figure 4.1 Alternative Flow Dispersal Trench NOTES: Figure 4.1 Alternative Flow Dispersal Trench NOTES: galvanized bolts 2" x 12" pressure treated grade board 2" x 2" notches 18" O.C. *20% max 12" min. 36" max 1' - 6" min *20% max 4" x 4" support post clean

More information

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

40'-0" PIPE SUPPORT (TYP.) (SEE DWG. NO. SK-2 OR DWG. NO. SK-4)

40'-0 PIPE SUPPORT (TYP.) (SEE DWG. NO. SK-2 OR DWG. NO. SK-4) SK-1 STANDARD LENGTH 4.301 40'-0" A 6" 2'-0" 9'-0" 9'-0" 9'-0" 9'-0" 2'-0" A 3" OF EXPOSED AT EACH END OF PIPE. PIPE SUPPORT (TYP.) (SEE DWG. NO. SK-2 OR DWG. NO. SK-4) EXPOSED PIPE MINIMUM GAUGE AND THICKNESS

More information

PART 1 COMMON FOR WATER & WASTEWATER CONSTRUCTION TITLE By Other Than Open Cut (Non-T.x.D.O.T. - Non Railroad) --- 101 Highway Crossing - All Wastewater Mains & Water Mains 12" and Smaller in Diameter.

More information

HAMILTON TOWNSHIP MUNICIPAL UTILITIES AUTHORITY

HAMILTON TOWNSHIP MUNICIPAL UTILITIES AUTHORITY HEIGHT TO REMOVE STRAINER ELEMENT D C G I E B H F J A Operating Characteristics Meter Normal Operating Range* AWWA Low Flow Maximum Size @100% Accuracy (±1.5%) Standard @95% Accuracy Intermittent Flow

More information

CITY OF FARGO SPECIFICATION SANITARY SEWER

CITY OF FARGO SPECIFICATION SANITARY SEWER SECTION 1200 SECTION 1200 CITY OF FARGO SPECIFICATION SANITARY SEWER PART 1 DESCRIPTION OF WORK (revised March, 2007) The work to be done under these Specifications and the accompanying drawings consist

More information

CHAPTER 6 - SANITARY SEWER

CHAPTER 6 - SANITARY SEWER CHAPTER 6 - SANITARY SEWER 6.1 GENERAL This section covers the requirements for PVC plastic sewer pipe materials and installation in sanitary sewer construction. 6.2 PIPE PVC gravity sewer pipe and fittings

More information

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 602 MARCH 1993 CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER 602.01 SCOPE 602.02 REFERENCES 602.05 MATERIALS TABLE OF CONTENTS

More information

CATCH BASIN ST-1 ENGINEERING DEPARTMENT PLATE NUMBER 3.33' 3.0' 2.0' 4.33' 3.0' 4.0' 1.00' TO BACK OF CURB LINE

CATCH BASIN ST-1 ENGINEERING DEPARTMENT PLATE NUMBER 3.33' 3.0' 2.0' 4.33' 3.0' 4.0' 1.00' TO BACK OF CURB LINE 3.33' 3.0' 2.0' 4.33' 4.0' 3.0' 1.00' TO BACK OF CURB LINE TOP OF GRATE ELEV. - SEE PLAN NEENAH CASTING R-3067-V OR AS NOTED ON PLANS. "INFA-SHIELD" SEAL OR EQUAL. RINGS (2 MIN., 1' MAX. OF RINGS AND MORTAR).

More information

CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER

CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER WATER MAIN 1. All open cut water main shall be polyvinyl chloride plastic (PVC) pressure pipe per AWWA specification

More information

SECTION 39 - MANHOLES TABLE OF CONTENTS 39-1 GENERAL PRECAST CONCRETE MANHOLES

SECTION 39 - MANHOLES TABLE OF CONTENTS 39-1 GENERAL PRECAST CONCRETE MANHOLES Section SECTION 39 - MANHOLES TABLE OF CONTENTS 39-1 GENERAL... 39-1 39-2 PRECAST CONCRETE MANHOLES... 39-1 39-2.01 Precast Concrete Storm Drain Manholes... 39-1 39-3 SADDLE MANHOLES... 39-2 39-3.01 Saddle

More information

NOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INST

NOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INST NOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INSTALL MANHOLE LIDS FLUSH WITH EXISTING GROUND SURFACE.

More information

SECTION PRECAST CONCRETE MANHOLES

SECTION PRECAST CONCRETE MANHOLES SECTION 03 48 10 PRECAST CONCRETE MANHOLES PART 1: GENERAL 1.01 SECTION INCLUDES A. Precast concrete manholes for sanitary sewers and water lines or as indicated on the Drawings. B. Precast concrete sanitary

More information

SECTION SANITARY SEWER SYSTEM

SECTION SANITARY SEWER SYSTEM SECTION 02530 SANITARY SEWER SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Section includes sanitary sewer system piping for collection of wastewater. B. Related Sections include but are not limited to: 1. Division

More information

Contact the Jurisdictional Engineer for materials allowed by each jurisdiction.

Contact the Jurisdictional Engineer for materials allowed by each jurisdiction. Design Manual Chapter 3 - Sanitary Sewers 3C - Facility Design 3C-1 Facility Design A. Capacity of Pipe Pipe sizes 15 inches and smaller should carry the peak flow at a depth of no more than 0.67 of the

More information

UNIVERSITY OF MISSOURI Hydronic Energy Distribution 2016 Q1

UNIVERSITY OF MISSOURI Hydronic Energy Distribution 2016 Q1 GENERAL: The scope of this document is to provide instruction for the installation and testing of chilled water piping installed for the University of Missouri. DESIGN GUIDELINES: 1. Materials 1.1. Pipe

More information

MAXIMUM TRENCH WIDTH AS REQUIRED SEE MEASUREMENT AND PAYMENT SECTION OF SPECIFICATIONS

MAXIMUM TRENCH WIDTH AS REQUIRED SEE MEASUREMENT AND PAYMENT SECTION OF SPECIFICATIONS REFER TO PAVEMENT PATCHING DETAIL FOR REQUIREMENTS ABOVE FINISHED SUBGRADE EL. MAXIMUM ALLOWABLE WIDTH OF PAVEMENT PATCH, SEE MEASUREMENT AND PAYMENT SECTION OF SPECIFICATIONS MAXIMUM TRENCH WIDTH AS REQUIRED

More information

TYPE "A" CATCH BASIN

TYPE A CATCH BASIN 27" 1.67' TO BACK OF CURB LINE TOP OF GRATE ELEV. - SEE PLAN NEENAH CASTING R-3250-BV OR APPROVED EQUAL. "INFI SHIELD" SEAL OR APPROVED EQUAL RINGS (2 MIN., 1' MAX. OF RINGS AND MORTAR). PLASTER OUTSIDE,

More information

PART 5 WATER SYSTEMS

PART 5 WATER SYSTEMS PART 5 WATER SYSTEMS Abbreviations and Symbols Plan 501 Abbreviations and symbols for water... 205 Concrete Boxes and Hardware 502 27" Frame and cover... 207 503 38" Frame and cover... 209 505 Concrete

More information

Public Water Supply District #2 of St. Charles County, Missouri

Public Water Supply District #2 of St. Charles County, Missouri Public Water Supply District #2 of St. Charles County, Missouri POLICIES, PROCEDURES, AND REQUIREMENTS FOR CONNECTION AND INSPECTIONS OF: RESIDENTIAL WATER AND/OR SEWER SERVICE CONNECTIONS COMMERCIAL WATER

More information

ADDENDUM NO. 1. Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities

ADDENDUM NO. 1. Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities ADDENDUM NO. TO Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities Date of Addendum: December, 00 Hethcoat & Davis, Inc. 78 Franklin Road,

More information

SECTION MEASUREMENT AND PAYMENT

SECTION MEASUREMENT AND PAYMENT SECTION 01026 PART 1 GENERAL 1.1 SECTION INCLUDES A. Explanation and Definitions B. Measurement C. Payment D. Schedule of Values E. Application for Payment 1.2 EXPLANATION AND DEFINITIONS A. The following

More information

SECTION SANITARY SEWER SYSTEM

SECTION SANITARY SEWER SYSTEM SECTION 02731 SANITARY SEWER SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Sanitary sewer system including necessary accessories indicated on drawings and specified in this section. Contractor

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES

San Antonio Water System Standard Specifications for Construction ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES 853.1 DESCRIPTION: This item shall govern the construction of FRP sanitary sewer complete in place and the material therein,

More information

ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES

ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES 853.1 DESCRIPTION: This item shall govern the construction of FRP sanitary sewer complete in place and the material therein,

More information

SECTION STORM DRAINAGE

SECTION STORM DRAINAGE SECTION 02720 STORM DRAINAGE PART 1 - GENERAL 1.01 WORK INCLUDED A. Trenching and other excavation. B. Ground water control. C. Pipe bedding. D. Installation of storm drains and appurtenances. E. Installation

More information

Table of Contents. Section Sanitary Sewers Section Includes Description of Work Submittals 1. 1.

Table of Contents. Section Sanitary Sewers Section Includes Description of Work Submittals 1. 1. Table of Contents Section 00 - Sanitary Sewers Page No. Part - General.0 Section Includes.0 Description of Work.03 Submittals.0 Substitutions.05 Delivery, Storage, and Handling.06 Scheduling and Conflicts.07

More information

Table of Contents. Section Structures for Sanitary and Storm Sewers Section Includes Description of Work 1. 1.

Table of Contents. Section Structures for Sanitary and Storm Sewers Section Includes Description of Work 1. 1. SUDAS Standard Specifications Division 6 - Structures for Sanitary and Storm Sewers Table of Contents Section 6010 - Structures for Sanitary and Storm Sewers Page No. Part 1 - General 1.01 Section Includes

More information

1 Revised: 2019 Edition

1 Revised: 2019 Edition STORM SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Storm Sewers B. Abandonment of Storm Sewers 1.02 DESCRIPTION OF WORK A. Construct storm sewers. B. Abandon storm sewers. 1.03 SUBMITTALS Comply with

More information

San Antonio Water System Specifications for Construction ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES

San Antonio Water System Specifications for Construction ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES 853.1 DESCRIPTION: This item shall govern the construction of FRP sanitary sewer manholes, complete in place and the materials

More information

PVC Fittings & Laterals for Solid-Wall PVC Sewer Pipe

PVC Fittings & Laterals for Solid-Wall PVC Sewer Pipe Design and Installation Guide PVC Fittings & Laterals for Solid-Wall PVC Sewer Pipe TABLE OF CONTENTS Introduction 2 Products 3 Main-Line Fittings & Service-Line Fittings 3-4 Connections to Dissimilar

More information

Table of Contents. Section Sanitary Sewers Section Includes Description of Work Submittals 1. 1.

Table of Contents. Section Sanitary Sewers Section Includes Description of Work Submittals 1. 1. Table of Contents Section 00 - Sanitary Sewers Page No. Part - General.0 Section Includes.0 Description of Work.03 Submittals.0 Substitutions.05 Delivery, Storage, and Handling.06 Scheduling and Conflicts.07

More information

SECTION FACILITY SANITARY SEWERS

SECTION FACILITY SANITARY SEWERS SECTION 22 13 13 FACILITY SANITARY SEWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

B. Fiberglass for construction in back lot easements placed on cast-in-place base.

B. Fiberglass for construction in back lot easements placed on cast-in-place base. Section 02083 PART 1 G E N E R A L 1.01 SECTION INCLUDES A. Fiberglass manholes for unpaved areas placed on top of a precast base to form a manhole. B. Fiberglass for construction in back lot easements

More information

A. Provide floor drains in all restrooms placed a minimum of 7 from back of wet wall, janitor closets, and mechanical rooms.

A. Provide floor drains in all restrooms placed a minimum of 7 from back of wet wall, janitor closets, and mechanical rooms. SECTION 22 13 00 FACILITY SANITARY SEWERAGE PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

SPECIAL SPECIFICATION 5925 Polyvinyl Cloride (PVC) Sewer Pipe and Fittings

SPECIAL SPECIFICATION 5925 Polyvinyl Cloride (PVC) Sewer Pipe and Fittings 1993 Specifications CSJ 0144-01-060 SPECIAL SPECIFICATION 5925 Polyvinyl Cloride (PVC) Sewer Pipe and Fittings 1. General. (1) Scope. This Section includes the furnishing, installation, and subsequent

More information

SECTION SANITARY SEWERAGE PART 1 GENERAL 1.01 RELATED DOCUMENTS

SECTION SANITARY SEWERAGE PART 1 GENERAL 1.01 RELATED DOCUMENTS SECTION 02530 - SANITARY SEWERAGE PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Table of Contents. Section Structures for Sanitary and Storm Sewers Section Includes Description of Work 1. 1.

Table of Contents. Section Structures for Sanitary and Storm Sewers Section Includes Description of Work 1. 1. SUDAS Standard Specifications Division 6 - Structures for Sanitary and Storm Sewers Table of Contents Section 6010 - Structures for Sanitary and Storm Sewers Page No. Part 1 - General 1.01 Section Includes

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION ITEM 02514 MANHOLES 1.0 GENERAL 1.1 SCOPE This section provides for construction of sewer manholes complete in place, including the furnishing and adjusting to grade of an existing

More information

Table of Contents. Section Structures for Sanitary and Storm Sewers Section Includes Description of Work 1. 1.

Table of Contents. Section Structures for Sanitary and Storm Sewers Section Includes Description of Work 1. 1. SUDAS Standard Specifications Division 6 - Structures for Sanitary and Storm Sewers Table of Contents Section 600 - Structures for Sanitary and Storm Sewers Page No. Part - General.0 Section Includes.0

More information

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms.

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms. PART 1: GENERAL 1.01 Purpose A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

BUILDING SEWER AND GRINDER PUMP CONNECTION & CONSTRUCTION STANDARDS

BUILDING SEWER AND GRINDER PUMP CONNECTION & CONSTRUCTION STANDARDS TOWN OF MILO, NEW YORK Department of Sewer and Water Attention: Doug Marchionda, Jr. Operator Jeffrey Finger Operator 137 Main Street Penn Yan, New York 14527 Telephone No.: (315) 536-8501 Facsimile No.:

More information

D. Encase exterior cleanouts in concrete with access cover installed flush with grade.

D. Encase exterior cleanouts in concrete with access cover installed flush with grade. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

SECTION 920 SANITARY AND STORM SEWER MANHOLES

SECTION 920 SANITARY AND STORM SEWER MANHOLES SECTION 920 SANITARY AND STORM SEWER MANHOLES 920.1 GENERAL This section contains items which are relative to the installation of sanitary and storm sewer manholes. 920.2 REFERENCES 920.2.1 ASTM C 43 C

More information

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection EFFECTIVE FEBRUARY 2014 note: drainage permit required to call for a dampproof inspection PERMITS & INSPECTIONS 750 17th Street West Vancouver BC V7V 3T3 westvancouver.ca/permits t: 604-925-7040 f: 604-925-7234

More information

2.1.2 Minimum wall thickness shall be 90 mm Frames and covers shall be bitumen coated by dipping.

2.1.2 Minimum wall thickness shall be 90 mm Frames and covers shall be bitumen coated by dipping. 1.0 GENERAL 1.1 Scope 2.0 PRODUCTS 1.1.1 The work shall consist of the construction, renovation or the adjustment of manholes and/or catchbasins as detailed on the plans or where designated by the Engineer

More information

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II SECTION 221313 - FACILITY SANITARY SEWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

D-1 THE CITY OF HARRISBURG 1 1/2" MIN. ID-2 WEARING COARSE EXISTING STREET SURFACE AC-20 SEALER (ALL AROUND) 1 1/2" MIN. ID-2 BINDER COARSE

D-1 THE CITY OF HARRISBURG 1 1/2 MIN. ID-2 WEARING COARSE EXISTING STREET SURFACE AC-20 SEALER (ALL AROUND) 1 1/2 MIN. ID-2 BINDER COARSE EXISTING STREET SURFACE 1 1/2" MIN. ID-2 BINDER COARSE 1 1/2" MIN. ID-2 WEARING COARSE AC-20 SEALER (ALL AROUND) 8" CLASS A P.C. CONCRETE SAW CUT TOP OF CONCRETE SHALL MEET SURFACE OF EXISTING CONCRETE.

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 33 3400 STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY CAST-IN-PLACE. Section CAST-IN-PLACE CONCRETE MANHOLES

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY CAST-IN-PLACE. Section CAST-IN-PLACE CONCRETE MANHOLES PART 1 GENERAL 1.01 SUMMARY This Section includes: Section 02081 CAST-IN-PLACE A. Cast-in-place concrete manholes for sanitary sewers and storm sewers, including box sewers. B. Pile-supported concrete

More information

Section Storm Sewers STORM SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Storm Sewers. B. Abandonment of Storm Sewers

Section Storm Sewers STORM SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Storm Sewers. B. Abandonment of Storm Sewers STORM SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Storm Sewers B. Abandonment of Storm Sewers 1.02 DESCRIPTION OF WORK A. Construct storm sewers. B. Abandon storm sewers. 1.03 SUBMITTALS Comply with

More information

SPECIAL SPECIFICATION 6664 Level (3) Communications System

SPECIAL SPECIFICATION 6664 Level (3) Communications System 2004 Specifications CSJ 1200-05-014 SPECIAL SPECIFICATION 6664 Level (3) Communications System 1. Description. A. This Item will govern the installation of all facilities belonging to Level (3) Communications,

More information

SPECIAL SPECIFICATION 6658 Time Warner Communications System

SPECIAL SPECIFICATION 6658 Time Warner Communications System 2004 Specifications CSJ 1200-05-014 1. Description. SPECIAL SPECIFICATION 6658 Time Warner Communications System A. This Item will govern the installation of all facilities belonging to Time Warner Cable

More information

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems SECTION 02607-1 1.0 GENERAL 1.1 SCOPE: A. This section covers the work necessary for the construction of sanitary and storm system manholes, catch basins, and miscellaneous concrete structures complete.

More information

SCALE BAR 1:2500 RM OF WOODLANDS OVERALL PLAN - LOW PRESSURE SEWER MAIN. Certificate of Authorization JESSICA MANNESS ENGINEERING, INC. No.

SCALE BAR 1:2500 RM OF WOODLANDS OVERALL PLAN - LOW PRESSURE SEWER MAIN. Certificate of Authorization JESSICA MANNESS ENGINEERING, INC. No. OF SURVEY OVERALL PLAN - LOW PRESSURE SEWER MAIN 0 50 100 SCALE BAR 1:2500 200 500 THIS IS NOT A LEGAL PLAN - CONCEPT ONLY OF SURVEY PLAN - LOW PRESSURE SEWER MAIN 0 50 100 SCALE BAR 1:2500 200 500 THIS

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 812 WATER MAIN INSTALLATION

San Antonio Water System Standard Specifications for Construction ITEM NO. 812 WATER MAIN INSTALLATION ITEM NO. 812 WATER MAIN INSTALLATION 812.1 DESCRIPTION: This item shall consist of water main installation in accordance with these specifications and as directed by the Engineer. 812.2 MATERIALS: The

More information

A. Gravity-Flow, Nonpressure, Drainage-Piping Pressure Rating: 10-foot head of water (30 kpa).

A. Gravity-Flow, Nonpressure, Drainage-Piping Pressure Rating: 10-foot head of water (30 kpa). SECTION 221313 - FACILITY SANITARY SEWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION 39 - MANHOLES TABLE OF CONTENTS

SECTION 39 - MANHOLES TABLE OF CONTENTS Section SECTION 39 - MANHOLES TABLE OF CONTENTS Page 39-1 GENERAL... 39.1 39-2 CONCRETE MANHOLES... 39.1 39-2.01 NOT USED... 39.1 39-2.02 Concrete Storm Drain Manholes... 39.1 39-3 SADDLE SEWER MANHOLES...

More information

SPECIAL SPECIFICATION 6666 Charter Communications System

SPECIAL SPECIFICATION 6666 Charter Communications System 2004 Specifications CSJ 1200-05-014 SPECIAL SPECIFICATION 6666 Charter Communications System 1. Description. A. This Item will govern the installation of all facilities belonging to Charter Communications,

More information

ITEM NO SLIPLINING SANITARY SEWERS

ITEM NO SLIPLINING SANITARY SEWERS ITEM NO. 1100 SLIPLINING SANITARY SEWERS 1100.1 DESCRIPTION: Sliplining is accomplished by pulling or pushing liner pipe into existing sewers by use of mechanical or hydraulic equipment. Once in place,

More information

PUBLIC WORKS DEPARTMENT GENERAL NOTES

PUBLIC WORKS DEPARTMENT GENERAL NOTES PUBLIC WORKS DEPARTMENT GENERAL NOTES 1. All construction shall be in strict accordance with the standards of the City of Southlake and governed by the North Central Texas Council of Government's Standard

More information

Effective Date: Revision #: 1. Section I: Castings and Aluminum Covers. Valve Boxes. Service Clean-out Box and Lid

Effective Date: Revision #: 1. Section I: Castings and Aluminum Covers. Valve Boxes. Service Clean-out Box and Lid Section I: Castings and Aluminum Covers I 1 I 2 I 3 I 4 Valve Boxes Service Clean-out Box and Lid Manhole Casting/ Standard Ring and Cover Access Covers/ Aluminum 1 I 1 VALVE BOXES: Valve boxes shall meet

More information

Changes for the. TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details

Changes for the. TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details Changes for the 2017 TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details The following changes are made to the existing standards and details to clarify or improve existing information.

More information

CUYAHOGA COUNTY DEPARTMENT OF PUBLIC WORKS - SANITARY DEPARTMENT DETAIL

CUYAHOGA COUNTY DEPARTMENT OF PUBLIC WORKS - SANITARY DEPARTMENT DETAIL STANDARD SPECIFICATIONS - SEWER MAINS AND APPURTENANCES DEVELOPER/ENGINEER PROCEDURES All Developer/Engineering Procedures as established by Cuyahoga County Department of Public Works (CCDPW) shall be

More information

Section 4 Service Lines

Section 4 Service Lines Section 4 Service Lines A. General 1. A service line is that portion of a sanitary sewer line that extends from the outer building wall or foundation wall to its connection with the sewer lateral at the

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 848 SANITARY SEWERS

San Antonio Water System Standard Specifications for Construction ITEM NO. 848 SANITARY SEWERS ITEM NO. 848 SANITARY SEWERS 848.1 DESCRIPTION: This item shall govern the furnishing, installation and jointing of sanitary sewer pipe of the size and type specified by the project's plans and specifications.

More information

TABLE OF CONTENTS

TABLE OF CONTENTS DIVISION 33: SEWER AND SEPTIC SYSTEMS 33 3633 UTILITY SEPTIC TANK DRAINAGE FIELD TABLE OF CONTENTS 33 0000-1 SECTION 33 3633-- UTILITY SEPTIC TANK DRAINAGE FIELD PART 1 - GENERAL 1.1 SUMMARY A. Includes

More information

SUPPLEMENTARY SECTION: STANDARD SPECIFICATIONS PAGE 1 STORMWATER MAINS & CULVERTS MAY 2018

SUPPLEMENTARY SECTION: STANDARD SPECIFICATIONS PAGE 1 STORMWATER MAINS & CULVERTS MAY 2018 STANDARD SPECIFICATIONS PAGE 1 STORMWATER MAINS & CULVERTS MAY 2018 PART 1 - GENERAL... 2 1.1 Work Included... 2 1.2 Related Sections... 2 1.3 Reference Standards... 2 1.4 Shop Drawings... 3 1.5 Certificates...

More information

CITY OF SCHERTZ TEXAS ENGINEERING AND PUBLIC WORKS

CITY OF SCHERTZ TEXAS ENGINEERING AND PUBLIC WORKS TEXAS STANDARD CONSTRUCTION NOTES DRWN. BY: DSGN. BY: KJW 1 of 2 *Place geotextile fabric as a permeable seperator to prevent mixing of coarse aggregate and underlying soil. (as needed). 1. GEOTEXTILE

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 813 WATER SERVICE FOR FIRELINES

San Antonio Water System Standard Specifications for Construction ITEM NO. 813 WATER SERVICE FOR FIRELINES ITEM NO. 813 WATER SERVICE FOR FIRELINES 813.1 DESCRIPTION: This item shall consist of water service for fire line installations in accordance with these specifications and as directed by the Engineer.

More information

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017 SECTION 02630 - STORM DRAINAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SANITARY SEWER GENERAL NOTES. Sanitary Sewer Construction Notes

SANITARY SEWER GENERAL NOTES. Sanitary Sewer Construction Notes Sanitary Sewer Construction Notes 1. All public sanitary sewer systems shall be constructed in accordance with the latest edition of the Washington State Department of Transportation Standard Specifications

More information

CITY OF OCEANSIDE. Electrical Lines, Plumbing and Mechanical Burial & Support Requirements. Informational Bulletin

CITY OF OCEANSIDE. Electrical Lines, Plumbing and Mechanical Burial & Support Requirements. Informational Bulletin Electrical Lines, Plumbing and Mechanical Burial & Support Requirements Informational Bulletin MINIMUM BURIAL DEPTH REQUIREMENTS 2016 CALIFORNIA ELECTRICAL CODE (CEC) Burial depth shall be per Table 300.5,

More information

SECTION PUBLIC WATER SERVICE CONNECTIONS

SECTION PUBLIC WATER SERVICE CONNECTIONS SECTION 33 14 14 PUBLIC WATER SERVICE CONNECTIONS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe and fittings for water service connections to small commercial, light industrial, and residential

More information

Project Location: Various, Anywhere, PA Bid Date: 7/16/ Rock Construction Entrance

Project Location: Various, Anywhere, PA Bid Date: 7/16/ Rock Construction Entrance To: Project Name: Bidding Company Site Work Project Contact: Address: Various Phone: Fax: Bid Number: Project Location: Various, Anywhere, PA Bid Date: 7/16/2014 Clarifications: This takeoff does not include

More information

ITEM 432 TUNNEL CONSTRUCTION

ITEM 432 TUNNEL CONSTRUCTION AFTER MARCH 1, 2012 ITEM 432 TUNNEL CONSTRUCTION 432.1 Description. This Item shall govern for tunnel lines under railroads, state highways, and concrete paved streets or other obstructions indicated.

More information

Summary of the 2011 Changes

Summary of the 2011 Changes The following is a list of amendments to the Residential Site Improvement s, N.J.A.C. 5:21, adopted in 2011. The Notice of Adoption of these changes appeared in the New Jersey Register on May 16, 2011.

More information

BEDDING AND TRENCHING TYPE A

BEDDING AND TRENCHING TYPE A SKGANDHI TRENCH WIDTH VARIES W/ SIZE OF PIPE FINISHED GRADE COMMON FILL SEE NOTE 4 PIPE O.D. (SEE NOTE 1) TRENCH BACKFILL (SEE NOTE 2) 12" (TYP) INITIAL BACKFILL (SEE NOTE 1) SELECT COMMON FILL BEDDING

More information

Beacon Hill Water & Sewer District Standard Specifications

Beacon Hill Water & Sewer District Standard Specifications Beacon Hill Water & Sewer District Standard Specifications STEP Sewer Systems Including: Design Criteria Standard Construction Drawings REVISED JANUARY 2012 Alternative sewer systems must meet the requirements

More information

CITY of DALLAS. Standard Drawings. & Oregon Standard Drawing Amendments. Water Drawings

CITY of DALLAS. Standard Drawings. & Oregon Standard Drawing Amendments. Water Drawings CITY of DALLAS Standard Drawings & Oregon Standard Drawing Amendments Water Drawings RD250 - Thrust Blocking RD254 - Hydrant Installation RD258 - Valve Box and Operator Extension Assembly RD262 - Standard

More information

Copper-Type K soft Drawn 40, 50 HDPE 100 and larger

Copper-Type K soft Drawn 40, 50 HDPE 100 and larger 1.0 GENERAL 1.1 Scope 1.1.1 The work covered by this section involves the installation of water and sewer service connections and all other associated work. 1.2 Authorization 1.2.1 Do not install service

More information

SECTION FACILITY SANITARY SEWERS

SECTION FACILITY SANITARY SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Gravity-flow, non-pressure sanitary sewerage outside the building, with the following components: 1.02 DEFINITIONS 1. Cleanouts. 2. Precast concrete manholes.

More information

DUKE UNIVERSITY CONSTRUCTION STANDARDS

DUKE UNIVERSITY CONSTRUCTION STANDARDS 1 33 11 00 Water Utility Distribution Piping 1. Introduction A. Duke University owns and operates the water distribution system throughout the campus boundaries; however, water is supplied by the City

More information

Section 403. DRAINAGE STRUCTURES

Section 403. DRAINAGE STRUCTURES 403.01 Section 403. DRAINAGE STRUCTURES 403.01. Description. This work consists of adjusting, constructing, or temporarily lowering drainage structures and cleaning existing drainage structures and leads

More information

CHAPTER 200 STORM SEWER CONSTRUCTION STANDARDS

CHAPTER 200 STORM SEWER CONSTRUCTION STANDARDS CHAPTER 200 STORM SEWER CONSTRUCTION STANDARDS Storm Sewer System: 1. Detention/retention of stormwater runoff shall be provided in accordance with the requirements of the DuPage County Countywide Stormwater

More information

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ELECTRICAL CHAMBERS

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ELECTRICAL CHAMBERS ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.PROV 602 NOVEMBER 2017 CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ELECTRICAL CHAMBERS TABLE OF CONTENTS 602.01 SCOPE 602.02 REFERENCES 602.03 DEFINITIONS

More information

Procedures for Connecting to Central Sewer System

Procedures for Connecting to Central Sewer System Procedures for Connecting to Central Sewer System These procedures and requirements are taken from the Taney County Regional Sewer District s appoved Sewer Use Regulation, Article 4 Building Sewers and

More information