AcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details
|
|
- Aubrey Hunter
- 6 years ago
- Views:
Transcription
1 Typical Details AcroWall-ES System Class PB Exterior Insulation and Finish System providing a primary moisture barrier 1. Typical AcroWall-ES System Application 2. Typical Aesthetic Reveal 3. Typical Window Head (Flush) 4. Typical Window Head (Recessed) 5. Typical Window Jamb (Flush) 6. Typical Window Jamb (Recessed) 7. Typical Window Sill (Flush) 8. Typical Window Sill (Recessed) 9. Typical Roof Edge Flashing 10. Typical Parapet Cap Flashing 11. Typical Parapet Cap 12. Typical Expansion Joint at Floorline 13. Typical Expansion Joint at Change in Substrate 14. Typical Transition at Soffit and Fascia 15. Typical Expansion Joint 16. Typical Pipe Penetration 17. Typical Corner Mesh 18. Typical Light Fixture 19. Typical Termination at Foundation 20. Typical Termination at Foundation (Flush) 21. Typical Kick-Out Flashing
2 TYPICAL ACROWALL-ES SYSTEM APPLICATION ES TYPICAL AESTHETIC REVEAL Maintain a minimum 19 mm (3/4 ) thick EPS insulation board behind all reveals & aesthetic grooves. Reinforcing mesh shall be continuous through the reveal and care shall be taken to ensure reinforcing mesh is encapsulated into the reveal and is not cut during base coat application. Horizontal reveals shall provide an outward positive drainage. Reveals must not occur at the abutment of two pieces of EPS insulation board. Reveals must not occur at the joints in sheathing. ES
3 Provide a properly configured back wrapped joint with backer rod and sealant at system terminations to dissimilar materials, ensuring that a watertight seal is achieved. EPS insulation board joint must not line up with corner of rough openings. TYPICAL WINDOW HEAD (FLUSH) ES Provide a properly configured back wrapped joint with backer rod and sealant at system terminations to dissimilar materials, ensuring that a watertight seal is achieved. EPS insulation board joint must not line up with corner of rough openings. TYPICAL WINDOW HEAD (RECESSED) ES
4 TYPICAL WINDOW HEAD (FLUSH) Provide a properly configured back wrapped joint with backer rod and sealant at system terminations to dissimilar materials, ensuring that a watertight seal is achieved. EPS insulation board joint must not line up with corner of rough openings. ES TYPICAL WINDOW JAMB (RECESSED) Provide a properly configured back wrapped joint with backer rod and sealant at system terminations to dissimilar materials, ensuring that a watertight seal is achieved. EPS insulation board joint must not line up with corner of rough openings. ES
5 Provide a properly configured back wrapped joint with backer rod and sealant at system terminations to dissimilar materials, ensuring that a watertight seal is achieved. EPS insulation board joint must not line up with corner of rough openings. TYPICAL WINDOW SILL (FLUSH) ES Provide a properly configured back wrapped joint with backer rod and sealant at system terminations to dissimilar materials, ensuring that a watertight seal is achieved. EPS insulation board joint must not line up with corner of rough openings. TYPICAL WINDOW SILL (RECESSED) ES
6 TYPICAL ROOF EDGE FLASHING Ensure that metal coping/flashing extends onto the system a minimum of 51 mm (2 ) and that the flange is sealed. ES TYPICAL PARAPET CAP FLASHING Ensure that metal coping/flashing extends onto the system a minimum of 51 mm (2 ) and that the flange is sealed. ES
7 Provide a minimum 6:12 slope for all horizontal surfaces greater than 25 mm (1 ). Acrocrete requires the use of a roofing system or metal cap flashing for sloped surfaces over 609 mm (24 ). Terminate system a minimum of 203 mm (8 ) above roof. Maintain a minimum 25 mm (1 ) thick EPS insulation board. TYPICAL PARAPET CAP ES Install expansion joints in the system at all changes in substrate, through existing expansion joints, floor lines in multi-level wood frame construction, and where movement is anticipated. It is the sole responsibility of the design professional to determine specific expansion joint location, placement and design. TYPICAL EXPANSION JOINT AT FLOORLINE ES
8 TYPICAL EXPANSION JOINT AT CHANGE IN SUBSTRATE Install expansion joints in the system at all changes in substrate, through existing expansion joints, floor lines in multi-level wood frame construction, and where movement is anticipated. It is the sole responsibility of the design professional to determine specific expansion joint location, placement and design. ES TYPICAL TRANSITION AT SOFFIT AND FASCIA Maintain a minimum 19 mm (3/4 ) thick EPS insulation board behind drip edge ES
9 Install expansion joints in the system at all changes in substrate, through existing expansion joints, floor lines in multi-level wood frame construction, and where movement is anticipated. It is the sole responsibility of the design professional to determine specific expansion joint location, placement and design. TYPICAL EXPANSION JOINT ES Ensure all penetrations through the system are properly sealed. TYPICAL PIPE PENETRATION ES
10 TYPICAL CORNER MESH Verify all materials are installed in accordance with installation instructions and applicable code. Ensure reinforcing mesh is continuously lapped a minimum of 203 mm (8 ) around corners. Stagger vertical joints in EPS insulation board at corners. ES TYPICAL LIGHT FIXTURE Verify all materials are installed in accordance with installation instructions and applicable code. Ensure all penetrations through the system are properly sealed. ES
11 Verify all materials are installed in accordance with installation instructions and applicable code. Terminate system a minimum of 203 mm (8 ) above grade. Extend system a minimum of 50 mm (2 ) and a maximum of 305 mm (12 ) at the foundation transition. TYPICAL TERMINATION AT FOUNDATION ES Verify all materials are installed in accordance with installation instructions and applicable code. TYPICAL TERMINATION AT FOUNDATION (FLUSH) ES
12 TYPICAL KICK-OUT FLASHING Terminate system a minimum of 51 mm (2 ) above roof. Ensure step flashing is a minimum of 51 mm (2 ) behind system. Kick-out flashing shall be a minimum of 102 mm (4 ) in height, angled at 100º minimum; seams must be soldered or sealed with appropriate ES
13 NOTES
14 NOTES
15 NOTES
16 Note BASF Wall Systems is an operating unit of BASF Corporation (herein after referred to as BASF Wall Systems ) Residential Policy Apply wall systems in accordance with local building codes in force at the time of construction. On one and two-family residential framed construction, BASF Wall Systems requires that the wall system selected be one that includes provisions for moisture drainage. Disclaimer This information and all further technical advice are based on BASF Wall Systems present knowledge and experience. However, BASF assumes no liability for providing such information and advice including the extent to which such information and advice may relate to existing third party intellectual property rights, especially patent rights. In particular, BASF Wall Systems disclaims any and all CONDITIONS AND WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY. BASF WALL SYSTEMS SHALL NOT BE RESPONSIBLE FOR CONSEQUENTIAL, INDIRECT OR INCIDENTAL DAMAGES (INCLUDING LOSS OF PROFITS) OF ANY KIND. BASF Wall Systems reserves the right to make any changes according to technological progress or further developments. It is the customer s responsibility and obligation to carefully inspect and test any incoming goods. Performance of the product(s) described herein should be verified by testing and carried out only by qualified experts. It is the sole responsibility of the customer to carry out and arrange for any such testing. Reference to trade names used by other companies is neither a recommendation, nor an endorsement of any product and does not imply that similar products could not be used. It is the responsibility of both the specifier and the purchaser to determine if a product is suitable for its intended use. The designer selected by the purchaser shall be responsible for all decisions pertaining to design, detail, structural capability, attachment details, shop drawings and the like. BASF Wall Systems has prepared guidelines in the form of specifications, typical application details, and product bulletins to facilitate the design process only. BASF Wall Systems is not liable for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or the like, whether based upon the information provided by BASF Wall Systems or otherwise, or for any changes which the purchasers, specifiers, designers or their appointed representatives may make to BASF Wall Systems published comments. For more information visit our website at BASF Wall Systems 3550 St. Johns Bluff Road South Jacksonville, FL Phone Fax BASF Corporation Printed in U.S.A. 08/10
Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details
Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier Typical Details (THIS PAGE INTENTIONALLY LEFT BLANK Pebbletex Wall System Class PB Exterior Insulation
More informationFinestone Stucco System
Typical Details Finestone Stucco System Cement Plaster Stucco 1. Typical Finestone Stucco System with Steel Framing 2. Typical Finestone Stucco System with Wood Framing 3. Typical Finestone Stucco System
More information3. Aesthetic Groove. 5. Window Head (Flush) 6. Window Head (Recessed) 7. Window Jamb Detail (Flush) 8. Window Jamb Detail (Recessed)
TYPICAL DETAILS Pebbletex-D10 System 1. Pebbletex-D10 Application (Plan VIew) 2. Pebbletex-D10 Design (Isometric View) 3. Aesthetic Groove 4. Insulation Boards / Reinforcing Mesh Application at Openings
More informationSentry Stucco Ultra Wall System
Typical Details Sentry Stucco Ultra Wall System Premium impact and puncture resistant, rain screen design cement plaster stucco system with enhanced water management 1. Typical Sentry Stucco Ultra Wall
More informationSenturion TM III Wall System
Senturion TM III Wall System TYPICAL DETAILS 1017666 1. Senturion III Wall System Application (Plan VIew) 2. Senturion III Wall System Application (Isometric View) 3. Aesthetic Groove (Plan VIew) 4. Insulation
More informationSenturion TM I Wall System
Senturion TM I Wall System TYPICAL DETAILS 1017662 1. Senturion I Wall System Application (Plan VIew) 2. Senturion I Wall System Application (Isometric View) 3. Aesthetic Groove (Plan View) 4. Insulation
More informationSenershield -R / Senershield -VB
Senershield -R / Senershield -VB Air / Water-Resistive Barrier Typical Details 1. Termination at Grade - Sheathing Overlapping Foundation 2. Termination at Grade - Sheathing Overlapping Foundation with
More informationAcrocrete Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor rigid insulation board
Acrocrete Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor rigid insulation board Acrocrete Platinum CI Stucco Typical details for an impact resistant
More informationAcrocrete Platinum CI Stucco Ultra Typical details for a premium impact and puncture resistant rain screen design cement plaster stucco system
Acrocrete Platinum CI Stucco Ultra Typical details for a premium impact and puncture resistant rain screen design cement plaster stucco system featuring Neopor rigid insulation board and Acrostop R Acrocrete
More informationFinestone Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor rigid insulation board
Finestone Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor rigid insulation board Finestone Platinum CI Stucco Typical details for an impact resistant
More informationFinestone Stucco Ultra Wall System
Finestone Stucco Ultra Wall System Premium impact and puncture resistant, rain screen design cement plaster stucco system with enhanced water management Typical Details BLANK PAGE Finestone Stucco Ultra
More informationMagnum Board Coatings
Master Wall Mesh and Base Coat Plastic Control Joint Accessory, Plastic Components 22027-16 or equal. See notes for placement recommendations Notes: Control joints are required and should be located by
More informationSenergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board
Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board NOTES Senergy Platinum CI Stucco Typical details for an
More informationSC-01 Cross-Section. Cement Board Substrate Master Wall Mesh and Base Coat Superior Finish
Master Wall Mesh and Base Coat Plastic Control Joint Accessory, Plastic Components 22027-16 or equal. See notes for placement recommendations Notes: Control joints are required and should be located by
More informationPAREXEIFS EXTERIOR INSULATION AND FINISH SYSTEM
PAREXEIFS EXTERIOR INSULATION AND FINISH SYSTEM PB EIF System Details The drawings and any related notes, or text contained thereon are based upon typical requirements of Parex, Incorporated exterior insulation
More informationSTRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C. Stratum Guard I and II System Installation Details
STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C Stratum Guard I and II System Installation Details Stratum Guard I and II DETAIL Table of Contents NOTE SG.0.0.01 SG.0.0.02
More informationStucco Resurfacing Systems. Repair with Confidence
Stucco Resurfacing Systems Repair with Confidence Repair with Confidence The common practice of patching and painting stucco cracks is only a short term fix. Finestone offers a longer-lasting approach
More informationDetail Booklet StoTherm ci XPS
Detail Booklet Series 53sxx Steel Frame Construction February 2017 professional, general contractor or builder They should be installed in accordance with those specifications and Sto s instructions Sto
More informationStucco Resurfacing Systems. Repair with Confidence
Stucco Resurfacing Systems Repair with Confidence Repair with Confidence The common practice of patching and painting stucco cracks is only a short term fix. Senergy offers a longer-lasting approach to
More informationR E S I D E N T I A L B U I L D E R S R E F E R E N C E G U I D E
DRYVIT SYSTEMS CANADA DSC504 R E S I D E N T I A L B U I L D E R S R E F E R E N C E G U I D E BUILDING SUCCESSFULLY WITH DRYVIT OUTSULATION RESIDENTIAL SYSTEMS INTRODUCTION Building Successfully with
More informationBUILDING SUCCESSFULLY WITH DRYVIT RESIDENTIAL SYSTEMS.
BUILDING SUCCESSFULLY WITH RESIDENTIAL S. DS504 THE FOLLOWING IS A LIST OF MAJOR CONSIDERATIONS THAT WILL HELP ENSURE A QUALITY INSTALLATION. SUBSTRATES (INSPECTION/WALK-AROUND) Prior to starting a job,
More informationParex USA Stucco Details CSI SECTION
Parex USA Stucco Details CSI SECTION 09 22 00 Note: The design specifications and construction shall comply with all local building codes and standards. Parex USA installation guidelines are for general
More informationWeatherSmart Air Barrier Installation Guide
WeatherSmart Air Barrier Installation Guide 1 The intent of this document is to provide a guide for the installation of WeatherSmart as both a Weather Resistive Barrier (W.R.B.) and an Air Barrier Material
More informationBUILDING SUCCESSFULLY WITH DRYVIT RESIDENTIAL SYSTEMS.
BUILDING SUCCESSFULLY WITH DRYVIT RESIDENTIAL SYSTEMS. DS504 THE FOLLOWING IS A LIST OF MAJOR CONSIDERATIONS THAT WILL HELP ENSURE A QUALITY DRYVIT INSTALLATION. SUBSTRATES (INSPECTION/WALK-AROUND) Prior
More informationPrimary Concerns and Defects
Primary Concerns and Defects Primary Concerns and Defects: Home Inspector Observations: Where to Look. What to Look For. What Observed condition may mean. Primary Concerns The points to be inspected per
More informationBULLETIN FROM THE FIRST COAST CHAPTER ICC~BOAF
FIRST COAST CHAPTER INTERNATIONAL CODE COUNCIL (ICC) AND BUILDING OFFICIALS ASSOCIATION OF FLORIDA, INC. (BOAF) SERVING BAKER, BRADFORD, CLAY, DUVAL, NASSAU, PUTNAM, ST. JOHNS & UNION COUNTIES BULLETIN
More informationReCote Finish System over Concrete
Part 1 General 1.01 GENERAL A. The Master Wall ReCote Finish System for smooth precast and cast in place concrete consists of an acrylic primer and ReCote acrylic finish. When needed an acrylic modified
More informationEIFS Rain Control EIFS. Face Sealed Perfect Barrier. Beware of EIFS: They must be done correctly They leak at joints Avoid moist sensitive substrate
EIFS Rain Control Both Drained and Perfect Barrier can be used Joints and Element can be designed differently Face Sealed Perfect Barrier The problem wall of the past Relies on sealant = dangerous Often
More informationWARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS
WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS Per: 2006 B.C.B.C. Part 9 DISCLAIMER: THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME
More informationA M E R I C A N A R C H I T E C T U R A L M A N U F A C T U R E R S A S S O C I A T I O N
A M E R I C A N A R C H I T E C T U R A L AAMA 2410-13 Standard Practice for Installation of Windows with an Exterior Flush Fin Over an Existing Window Frame M A N U F A C T U R E R S A S S O C I A T I
More informationINSTALLING WATER-RESISTIVE BARRIERS & FLASHING
INSTALLING WATER-RESISTIVE BARRIERS & FLASHING IN A TWO-LAYER STUCCO APPLICATION Fortifiber Building Systems Group provides this guide to assist installers by demonstrating a two-layer installation of
More informationLOWER MACUNGIE TOWNSHIP COMMUNITY CENTER ADDITIONS AND RENOVATIONS
SECTION 07.2419 - WATER-DRAINAGE EXTERIOR INSULATION AND FINISH SYSTEM (EIFS) PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. EIFS-clad drainage-wall assemblies that are field applied over substrate.
More informationDOWSIL Silicone Transition System: Application Guide Build a Better Barrier
High Performance Building Consumer Solutions DOWSIL Silicone Transition System: Application Guide Build a Better Barrier DOWSIL Silicone Transition System Application Guide The DOWSIL Silicone Transition
More informationCommercial Flashing Details
This technical note illustrates many of the most common flashing details for commercial buildings. The purpose for flashing is to direct moisture to the exterior and in so doing, prevent moisture from
More information2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:
SECTION 07651 FLEXIBLE COPPER SHEET FLASHINGS Advanced Building Products, Inc. manufacturer many types of flexible copper sheet flashings. Due to their ductility, high tensile strength, and resistance
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1504 Reissued 03/2017 This report is subject to renewal 03/2018. DIVISION: 07 00
More informationWEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS
WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS Window Fastening Although all possible measures have been taken to insure the accuracy of the material presented, WIXSYS, and the author are not
More informationThe better way to build TM. Installation Manual NAILBASE PANELS
The better way to build TM Installation Manual PANELS November 2018 SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................
More informationTHIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150
THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150 SECTION ONE A. Objective The objective of this guide is to provide Owners and General Contractors/Construction
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3172 Reissued 02/2018 This report is subject to renewal 02/2019. DIVISION: 07 00
More informationThird Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration
Third Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration DS497 SECTION ONE A. Objective The objective of this guide is to provide owners and general contractors/construction
More informationArchitectural Wall Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is
More informationInstallation Guide Sto RapidGuard
ATTENTION Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional, general
More informationAquaFlash System Installation Guide DS196
AquaFlash System Installation Guide I. General: A. This document provides guidelines for the application and use of the Dryvit AquaFlash System at rough openings for windows, doors and other penetrations,
More informationNational Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 Section [ ].
National Master Specification (NMS) Section 07 21 16 BLANKET INSULATION Publisher: Spex.ca Page 1 Approved: 2014-12-31 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section [ ]. 1.2 REFERENCES.1 CSA Group.1
More informationENVELOPE The Ultimate In Performance In A Wet-Sealed System ROUT & RETURN (RR) SYSTEM TECHNICAL MANUAL
ENVELOPE 2000 ROUT & RETURN (RR) SYSTEM The Ultimate In Performance In A Wet-Sealed System TECHNICAL MANUAL System Assembly Substrate Layouts CAD Sections/Details Physical Properties Performance Properties
More informationKARRIER PANEL - BRICK
KPH-DS-01-BRICK KPH-PJ-01-BRICK KPH-PJ-02-BRICK KPH-PJ-03-BRICK KPH-BS-01-BRICK KPH-BS-02-BRICK KPH-BS-03-BRICK KPH-OC-01-BRICK KPH-FO-01-BRICK KPH-FO-02-BRICK KPH-FO-03-BRICK KPH-FO-04-BRICK KPH-FO-05-BRICK
More informationSto Guide Specification No. F601S StoQuik Gold Finish System for Soffits and Ceilings
Sto Corp. 3800 Camp Creek Parkway Building 1400, Suite 120 Atlanta, GA 30331 Tel: 404-346-3666 Toll Free: 1-800-221-2397 Fax: 404-346-3119 www.stocorp.com Sto Guide Specification No. F601S StoQuik Gold
More informationSingle Component 100% Silicone Sealant INSTALLATION INSTRUCTIONS
OVERVIEW VaproBond is a single component 100% silicone sealant designed to function as an adhesive sealant and an allweather silicone liquid flashing material. APPLICATION VaproBond is appropriate for
More informationInsulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS
Insulation First Revison October 2016 DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS 1. General Information This Guide describes the use of Kingspan GreenGuard DC14 Drainage
More informationGLOBAL PROPERTY INSPECTIONS TECHNICAL BULLETIN
GLOBAL PROPERTY INSPECTIONS TECHNICAL BULLETIN TM June 1, 2002 TOPIC: Exterior Coverings This is the sixth in a series of technical bulletins in which an over-all examination of the home will be discussed
More informationSenergy Reinforcing Mesh
Description Balanced, open-weave glass, fiber reinforcing mesh, twisted multi-end strands treated for compatibility with Senergy Base Coats. A variety of types are available to meet the different requirements
More informationer Build it right, start to finish TM
WORLD-CLASS STARTER BOARDS TM er Build it right, start to finish TM FASTER, STRONGER AND BETTER THAN BACK WRAPPING IBC Code Approved ESR-2931, Full Dryvit Warranty AC9052 WHY DRYVIT SHAPES BY ACROCORE
More informationSRP-AirOutshield UV Issued:
SECTION 07276: SRP-AirOutshield UV Ultra Violet (UV) resistant, Vapour Permeable Air Barrier Underlayment and Sheathing Membrane Guide Specification This specification is a guide only and may need editing
More information.1 Provide textured finish system for gypsum or cement board soffit and ceiling surfaces.
Page 1 of 5 SPEC NOTE: IMPORTANT: This guide specification covers installation of a textured finish system over building code compliant soffit or ceiling construction. It does not address air sealing,
More informationDow Corning Silicone Air Barrier System. A more. energy-efficient. shade. green
Silicone Air Barrier System of shade energy-efficient A more green Air and Moisture Protection for More Energy-Efficient Buildings Meeting regulatory requirements for energy efficiency is a significant
More informationProduct and System Specifications DuPont Flashing Systems
DuPont Building Innovations March 2007 4417 Lancaster Pike Chestnut Run Plaza 721 Wilmington, DE 19805 1-800-448-9835 www.construction.tyvek.com Product and System Specifications DuPont Flashing Systems
More informationELEVATION FOR DETAIL REFERENCE ONLY
6 7 8 10 26 19 20 14 15 22 SOFFIT OUTSIDE CORNER INSIDE CORNER 23 25 24 25 5 27 28 29 16 11 OPENING 17 18 END WALL 21 12 13 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CSH-01 CSH-02 CSH-03 CSH-04 CSH-05
More informationBuilding Envelope Enclosures That Work, What Owners Want!
WEBINAR February 23, 2017 Building Envelope Enclosures That Work, What Owners Want! Will Ikerd, P.E. (TX), LEED AP Webinar Speakers Karl Strand President of Vertical Solutions Consulting Will Ikerd, PE
More information19 East Ave. Mullica Hill, N.J Phone: Fax: ARCHITECTURAL FOAM FABRICATORS, LLC.
Table of Contents Trims...1-17 Sills...18-21 Frieze Boards...22-23 Cornices...24-28 Bands...29-32 Keystones...33-35 Pilasters...36 Columns...37-39 Quoins...40 Arches & Circles...41-42 4 1/2 Trims 7 6 14
More informationSenergy Reinforcing Mesh
Description Balanced, open-weave glass, fiber reinforcing mesh, twisted multi-end strands treated for compatibility with Senergy Base Coats. A variety of types are available to meet the different requirements
More informationREPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3914 Reissued 10/2017 This report is subject to renewal 10/2018. DIVISION: 07 00
More informationELEVATION FOR DETAIL REFERENCE ONLY
6 7 8 10 OUTSIDE CORNER 19 20 4 5 11 21 22 15 16 13 12 OPENING 14 SOFFIT 18 END WALL 17 INSIDE CORNER 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CCV-01 CCV-02 CCV-03 CCV-04 CCV-05 CCV-06 CCV-07 CCV-08
More informationAquaFlash System Installation Guide
AquaFlash System Installation Guide I. General: A. This document provides guidelines for the application and use of the Dryvit AquaFlash System at rough openings for windows, doors and other penetrations,
More informationGensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION
SECTION 072700 VAPOR PERMEABLE AIR BARRIER LIQUID MEMBRANE PART 1 GENERAL 1.1 GENERAL REQUIREMENTS A. The Work of this Section, as shown or specified, shall be in accordance with the requirements of the
More informationNCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology FLASHING DETAILS FOR CONCRETE MASONRY WALLS TEK 19-5A Water Penetration Resistance
More informationArchitectural Roof Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification
More informationAS Interpretation of External Waterproofing as it applies to Melbourne, Class 1 buildings
AS4654.2 Interpretation of External Waterproofing as it applies to Melbourne, Class 1 buildings Climate Zone: 6 Wind Class: N1 Membrane Types: Liquid Applied Class II and Class III as defined and tested
More informationContainer Installation Guide
Continuous Insulation Container Installation Guide Panels and InSerts The InSoFast CX Container panel and the InSerts are designed to fit most shipping containers. Containers have three types of corrugations:
More informationapplication instructions
application instructions FOUNDATIONS 76 & 120 SERIES PRIMED PANEL SIDING ARCHITECTURAL COLLECTION REVERSE BOARD & BATTEN AND STUCCO PANEL SIDING General At the time of manufacture, siding meets or exceeds
More informationDIVISION 7 THERMAL AND MOISTURE PROTECTION
DIVISION 7 THERMAL AND MOISTURE PROTECTION UCSC Campus Standards Handbook Waterproofing Standards 07100 1 SECTION 07100: WATERPROOFING STANDARDS A. Guarantee 1. Provide a guarantee on Contractor's letterhead
More informationEXTERIOR INSULATION & FINISH SYSTEMS PRELIMINARY INFORMATION
EXTERIOR INSULATION & FINISH SYSTEMS PRELIMINARY INFORMATION Style of Structure: Two Story. Estimate age of Structure: The house is 5-10 years old. Foundation: Utility Basement. Finished into living space
More informationEclipse Energy Guard. Product Information & Installation Manual General Installation Requirements
Product Information & Installation Manual 01 Important Notice to Buyers and Users of RoyOMartin wall system These instructions are not intended to cover every installation requirement, application, detail
More informationStucco Moisture Inspection Report
Website:www.ibgoodinspector.com E-Mail:support@ibgoodinspector.com January 11, 2006 Stucco Moisture Inspection Report Property Address 123 Our Street OurTown, USA 12345 Report Ordered By: Mr. & Mrs. Client
More information7.0 - EXAMPLE DETAILS
7.0 - EXAMPLE DETAILS The drawings represented herein are believed to be accurate and conforming to current design and construction practices. However, the drawings should be used as a reference guide
More informationENVELOPE The Ultimate In Performance In A Dry-Joint System RAINSCREEN (RS) SYSTEM TECHNICAL MANUAL
ENVELOPE 2000 RAINSCREEN (RS) SYSTEM The Ultimate In Performance In A Dry-Joint System TECHNICAL MANUAL System Assembly Substrate Layouts CAD Sections/Details Physical Properties Performance Properties
More informationCase Study: 1906 Clapboard House
Case Study: 1906 Clapboard House This 1906 house was cold even though the walls had blown-in insulation. The old drafty single pane windows were painted shut. The interior of the house was in pristine
More informationHow do you install yours?
How do you install yours? Darrell Paul Qualistat Building Performance Consultants CSA 440 Just about adding Peel & Stick? 1 Window and door problems Photos / videos Video available for viewing at INSTAGRAM
More informationContainer Installation Guide
Container Insulation Container Installation Guide Panels and Inserts The InSoFast CX Container panel and the Inserts are designed to fit most shipping containers. Containers have three types of corrugations:
More informationFINESCREEN 500. Part 1 - General. Section Impact Resistant Cement Board Stucco Wall System 1.1 GENERAL REQUIREMENTS
SPECIFICATION 1022566 Section 09200 FINESCREEN 500 Impact Resistant Cement Board Stucco Wall System Part 1 - General 1.1 GENERAL REQUIREMENTS 1.1.1 Refer to all drawings and other sections of this specification
More informationArchitectural Roof Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification
More informationDetail Booklet StoTherm ci Mineral Series 56s.xx CAE Steel Frame Construction February 2019
Detail Booklet Series 56s.xx CAE Steel Frame Construction February 2019 Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly
More informationESR-1061 Reissued May 1, 2011 This report is subject to renewal in two years.
ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 21 00 Thermal Insulation Section: 07 25 00 Water-Resistive Barriers/Weather
More informationFACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET
KPH-DS-01-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV KPH-BS-04-MTLV KPH-OC-01-MTLV KPH-IC-01-MTLV KPH-SF-01-MTLV KPH-SF-02-MTLV
More informationGCP APPLIED TECHNOLOGIES PERM-A-BARRIER VPL 50
MASONRY ANCHOR DETAILING:. GASKETED STANDOFF ANCHOR 0 MIN.. SURFACE MOUNTED ANCHOR " MIN. 7 9. LADDER STYLE ANCHOR.. MASONRY ANCHOR DETAILING. S00, -INCH TROWELED BEAD. MORTAR COLLECTION MESH. PERM-A-BARRIER
More informationMagnum Board Section Digicon Information Inc. Page 1
Digicon Information Inc. Page 1 This section includes sheathing for exterior walls for use in a potentially damp or wet exterior cladding environment. This sheathing section forms an exterior flat plane
More informationSECTION Exterior Insulation and Finish System WM Specification
SECTION 072419 Exterior Insulation and Finish System WM Specification Part 1 GENERAL 1.01 SECTION INCLUDES A. Exterior Insulation and Finish System (EIFS) Class WM as defined by EIFS Industry Members Association.
More informationAqua Coast Engineering
Aqua Coast Engineering Ltd. P.O. Box 1367 Station A Delta, B.C. V4M 3Y8 Tel: (604)948-0958 Fax: 604)948-0959 September 1, 2011 Matthew Cheng File#:11145 Matthew Cheng Architect Inc. Fax: 604-731-3908 Unit
More informationInsulating Concrete Form (ICF) Texture Finish
100% ACRYLIC TEXTURED COATINGS Insulating Concrete Form (ICF) Texture Finish MANUFACTURER SPECIFICATION SECTION 09960 CARRARA ICF TEXTURE FINISH PART I GENERAL 1.01 SUMMARY A. This document contains all
More informationSSL-175. Specifications
SSL-175 Specifications Everlast Metals 10 Enterprise Court Lebanon, PA 17042 Phone: (717) 270-6554 Fax: (717) 270-6569 www.everlastmetals.com 7410 Preformed Metal Roofing PART 1: GENERAL 1.01 SECTION INCLUDES
More informationSenergy Base Coats / Adhesives Fast setting dry-mix polymer adhesive. Product Bulletin
Senergy Base Coats / Adhesives Fast setting dry-mix polymer adhesive Product Bulletin Senergy Base Coats / Adhesives DESCRIPTION STANDARD is a 100% acrylic based product that is field mixed with Type I
More informationDL-200. Specifications
DL-200 Specifications Everlast Metals 10 Enterprise Court Lebanon, PA 17042 Phone: (717) 270-6554 Fax: (717) 270-6569 www.everlastmetals.com 7410 Structural Preformed Metal Roofing PART 1: GENERAL 1.01
More informationSecurock ExoAir 430 System Installation
Securock ExoAir 430 System Installation Table of Contents APPROVED DETAILING COMPONENTS 3 ADDITIONAL TREMCO MATERIALS 4 GENERAL 4-5 DELIVERY AND JOB SITE STORAGE 6 FRAMING 6 PANEL CUTTING AND APPLICATIONS
More informationDesign No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1
FIRESTOP JOINT SPRAY CFS-SP WB SILICONE JOINT SPRAY CFS-SP SIL F-RATING 2-HR. 2-HR. T-RATING -HR. -HR. APPLICATION THICKNESS PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table /8" WET FILM (/6"
More informationWrapShield SA Brick Tie Penetration
Brick Tie Penetration Outboard Vapor - Pemeable Insulation WrapShield SA Self-adhered WRB/AB field membrane Brick Tie must be Flush and compressed against Membrane with no prong penetrations Gasketed Fastener
More informationMoisture Survey Inspection Report
Moisture Survey Inspection Report Date of Inspection: January 1, 2017 For the property located at: 123 Pleasant Lane Pleasantville, Washington, 98999 Report prepared for: John and Jane Doe Professional
More informationSto Guide Specification No. F477 Sto Interior Finish System for Pool Rooms
Sto Corp. 3800 Camp Creek Parkway Building 1400, Suite 120 Atlanta, GA 30331 Tel: 404-346-3666 Toll Free: 1-800-221-2397 Fax: 404-346-3119 www.stocorp.com Sto Guide Specification No. F477 Sto Interior
More informationPella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...
SECTION DIRECTORY General Information Introduction... V250-ID-886 Installation Accessories and Applications... V250-ID-886 Typical Sealant Placement Details... V250-ID-887 Fin Installation Details Wood
More information