XHBN.FF-D Joint Systems. Design/System/Construction/Assembly Usage Disclaimer. Joint Systems. System No. FF-D-1066

Size: px
Start display at page:

Download "XHBN.FF-D Joint Systems. Design/System/Construction/Assembly Usage Disclaimer. Joint Systems. System No. FF-D-1066"

Transcription

1 XHBN.FF-D Page 1 of 2 9/18/2009 Page Bottom XHBN.FF-D-1066 Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Listed or Classified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered as Classified, Listed, or Recognized. See General Information for System No. FF-D-1066 March 20, 2006 Assembly Rating 2 Hr Nominal Joint Widths 3, 4, 5 and 6 In. (See Item 2A) Class II and III Movement Capabilities 50% Compression, Extension or Horizontal Shear 1. Floor Assembly Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) structural concrete. 2. Joint System Max width of joint (at time of installation of joint system) is 3, 4, 5 or 6 in. (76, 102, 127 or 152 mm). The joint system is designed to accommodate a max 50 percent compression, extension or horizontal shear from its installed width. The joint system consists of the following: A. Mechanical Joint Assembly Fire barrier material encased in corrugated metal and provided with

2 XHBN.FF-D Page 2 of 2 9/18/2009 metal flanges. Assembly to be installed in floor in accordance with the installation instructions provide with the product. The following assemblies are to be used with the different joint sizes: Nom Joint Width In. (mm) 3 (76) MFX-3F 4 (102) MFX-4F 5 (127) MFX-5F 6 (152) MFX-6F Mechanical Joint Designation CONSTRUCTION SPECIALTIES INC B. Retaining Angles Stair-stepped 20 gauge (or heavier) galvanized steel angles installed over metal flanges of joint assembly in accordance with the installation instructions provide with the product. Angles to extend entire length of joint and are to be attached to floor with min 3/16 in. (5 mm) diam by 1-1/2 in. (38 mm) long masonry anchors spaced a max of 18 in. (457 mm) on center. C. Joint Cover Min in. (0.9 mm) thick metallic cover plates secured to top side of floor, continuous over full length of joint. Cover plate attached to floor on one side of opening only with min 1-1/2 in. (38 mm) long masonry anchors spaced a max of 18 in. (457 mm) on center. As an alternate, where the linear joint opening is enclosed within a chase wall and is non load bearing, a cover consisting of a creased sheet of min 2 mil (0.05 mm) thick stainless steel foil secured with 1 in. (25 mm) wide continuous galv steel washer strips along each side of the joint opening may be used. *Bearing the UL Classification Mark Last Updated on Questions? Notice of Disclaimer Page Top Copyright 2009 Underwriters Laboratories Inc. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright 2009 Underwriters Laboratories Inc. "

3 XHBN.FW-D file://t:\ul Listings\MFX\XHBN_FW-D htm Page 1 of 3 6/5/2008 Page Bottom XHBN.FW-D-1062 Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Listed or Classified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered as Classified, Listed, or Recognized. See General Information for System No. FW-D-1062 March 20, 2006 Assembly Rating 2 Hr Nominal Joint Widths 3, 4, 5 and 6 In. (See Item 3A) Class II and III Movement Capabilities 50% Compression, Extension or Horizontal Shear

4 XHBN.FW-D Page 2 of 3 1. Floor Assembly Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) structural concrete. 2. Wall Assembly* Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) structural concrete. Wall may also be constructed of any UL Classified Concrete Blocks*. See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 3. Joint System Max width of joint (at time of installation of joint system) is 3, 4, 5 or 6 in. (76, 102, 127 or 152 mm). The joint system is designed to accommodate a max 50 percent compression, extension or horizontal shear from its installed width. The joint system consists of the following: A. Mechanical Joint Assembly Fire barrier material encased in corrugated metal and provided with metal flanges. Assembly to be installed in floor in accordance with the installation instructions provide with the product. The following assemblies are to be used with the different joint sizes: Nom Joint Width In. (mm) Mechanical Joint Designation 3 (76) MFX-3FW 4 (102) MFX-4FW 5 (127) MFX-5FW 6 (152) MFX-6FW CONSTRUCTION SPECIALTIES INC B. Retaining Angles Min 24 gauge (or heavier) galvanized steel angles installed over metal flanges of joint assembly in accordance with the installation instructions provided with the product. Angles to extend entire length of joint and are to be attached to floor with min 3/16 in. (5 mm) diam by 1-1/2 in. (38 mm) long masonry anchors spaced a max of 18 in. (457 mm) on center. C. Retaining Clips Min 24 gauge galvanized steel clips installed over metal flanges of joint assembly in accordance with installation instructions provided with the product. Clips to extend entire length of joint and are to be attached to wall with min 3/16 in. (5 mm) diam by 1-1/2 in. (38 mm) long masonry anchors spaced a max of 18 in. (457 mm) on center. D. Joint Cover Min in. (0.9 mm) thick metallic cover plates installed on top side of floor, continuous over full length of joint. Cover plate attached only to wall with min 1-1/2 in. (38 mm) long file://t:\ul Listings\MFX\XHBN_FW-D htm 6/5/2008

5 XHBN.FW-D file://t:\ul Listings\MFX\XHBN_FW-D htm Page 3 of 3 6/5/2008 masonry anchors spaced a max of 18 in. (457 mm) on center. As an alternate, where the linear joint opening is enclosed within a chase wall and is non load bearing, a cover consisting of a creased sheet of min 2 mil (0.05 mm) thick stainless steel foil secured with 1 in. (25 mm) wide continuous galv steel washer strips along each side of the joint opening may be used. *Bearing the UL Classification Mark Last Updated on Questions? Notice of Disclaimer Page Top Copyright 2008 Underwriters Laboratories Inc. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright 2008 Underwriters Laboratories Inc. "

6 XHBN.WW-D Page 1 of 2 5/15/2007 XHBN.WW-D-1057 Page Bottom See General Information for System No. WW-D-1057 March 20, 2006 Assembly Rating 2 Hr Nominal Joint Width 3, 4, 5 and 6 In. (See Item 2A) Class II and III Movement Capabilities 50% Compression, Extension Or Vertical Shear 1. Wall Assembly Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) structural concrete. Wall may also be constructed of any UL Classified Concrete Blocks*. See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 2. Joint System Max width of joint (at time of installation of joint system) is 3, 4, 5 or 6 in. (76, 102, 127 or 152 mm). The joint system is designed to accommodate a max 50 percent compression, extension or vertical shear from its installed width. The joint system consists of the

7 XHBN.WW-D Page 2 of 2 5/15/2007 following: A. Mechanical Joint Assembly Fire barrier material encased in corrugated metal and provided with metal flanges. Assembly to be installed on either side of wall in accordance with the installation instructions provide with the product. The following assemblies are to be used with the different joint sizes: Nom Joint Width In. (mm) 3 (76) MFX-3W 4 (102) MFX-4W 5 (127) MFX-5W 6 (152) MFX-6W Mechanical Joint Designation CONSTRUCTION SPECIALTIES INC B. Retaining Angles Min 2-1/2 by 2-1/2 in. (64 by 64 mm) No. 20 gauge (or heavier) galvanized steel angles installed over steel flanges of joint. Angles to extend entire length of joint and are to be attached to wall assembly with min 1/4 in. (6 mm) diam by 1-1/2 in. (38 mm) long masonry anchors spaced a max of 18 in. (457 mm) on center. C. Joint Cover Min in. (0.9 mm) thick metallic cover plates secured to each side of wall, continuous over full height of joint. Cover plates attached to wall on one side of opening only with min 1/4 in. (6 mm) diam by 1-1/2 in. (38 mm) long masonry anchors spaced a max of 18 in. (457 mm) on center. As an alternate, in the area from the finished ceiling to the floor above, a cover consisting of a creased sheet of min 2 mil (0.05 mm) thick stainless steel foil secured with 1 in. (25 mm) wide continuous galv steel washer strips along each side of the joint opening may be used. *Bearing the UL Classification Mark Last Updated on Questions? Notice of Disclaimer Page Top Copyright 2007 Underwriters Laboratories Inc. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright 2007 Underwriters Laboratories Inc. "

8

9

10

XHBN.FF-D Joint Systems. Joint Systems. System No. FF-D-3008

XHBN.FF-D Joint Systems. Joint Systems. System No. FF-D-3008 XHBN.FF-D-3008 - Page 1 of 2 XHBN.FF-D-3008 Page Bottom See General Information for System No. FF-D-3008 March 20, 2006 Assembly Rating 2 Hr Nominal Joint Widths 14, 16, 18 and 20 In. (See Item 2A) Class

More information

Joint Systems. System No. FF-D-0044

Joint Systems. System No. FF-D-0044 XHBN.FF-D-0044 System No. FF-D-0044 November 05, 2003 Assembly Rating 2 Hr Nom Joint Width 1 in. Class II and III Movement Capabilities 50% Compression or Extension 1. Floor or Wall Assembly Reinforced

More information

XHBN.HW-D Joint Systems. Design/System/Construction/Assembly Usage Disclaimer. Joint Systems. System No. HW-D-0631

XHBN.HW-D Joint Systems. Design/System/Construction/Assembly Usage Disclaimer. Joint Systems. System No. HW-D-0631 Page Bottom XHBN.HW-D-0631 Joint Systems Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering

More information

BXUV.V481. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

BXUV.V481. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263 Page Bottom BXUV.V481 Fire Resistance Ratings - ANSI/UL 263 Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements

More information

BXUV.U435. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

BXUV.U435. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263 Page Bottom BXUV.U435 Fire Resistance Ratings - ANSI/UL 263 Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements

More information

JB ENGINEERING AND CODE CONSULTING, P.C Cardinal Drive Munster, IN Phone: Fax:

JB ENGINEERING AND CODE CONSULTING, P.C Cardinal Drive Munster, IN Phone: Fax: JB ENGINEERING AND CODE CONSULTING, P.C. 1661 Cardinal Drive Munster, IN 46321 Phone: 219-922-6171 Fax: 219-922-6172 E-Mail: JBEngineer@aol.com JULIUS A. BALLANCO, P.E. President January 15, 2008 Mr. Rick

More information

UL Online Certifications Directory

UL Online Certifications Directory Design No. N782 August 03, 2006 Restrained Beam Ratings 1, 1-1/2, 2, 3 and 4 Hr Unrestrained Beam Ratings 1, 1-1/2, 2, 3 and 4 Hr Load Restricted for Canadian Applications See Guide BXUV7 1. Steel Beam

More information

Design No. U415 BXUV.U415 Fire-resistance Ratings - ANSI/UL 263. Design No. U415

Design No. U415 BXUV.U415 Fire-resistance Ratings - ANSI/UL 263. Design No. U415 Design No. U415 BXUV.U415 Fire-resistance Ratings - ANSI/UL 263 Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the

More information

UL Design System HW-D-1012 continued

UL Design System HW-D-1012 continued UL System No. HW-D-1012 Assembly Ratings 1, 2 and 3 Hr (See Item 2) Nominal Joint Width 3 in. Class II and III Movement Capabilities 100% Compression or Extension Page 1 of 5 1. Floor Assembly The fire-rated

More information

EVALUATION REPORT OF CENTRAL STATES MANUFACTURING, INC. 'CENTRAL-LOC PANEL' FLORIDA BUILDING CODE 5TH EDITION (2014) FLORIDA PRODUCT APPROVAL

EVALUATION REPORT OF CENTRAL STATES MANUFACTURING, INC. 'CENTRAL-LOC PANEL' FLORIDA BUILDING CODE 5TH EDITION (2014) FLORIDA PRODUCT APPROVAL - EVALUATION REPORT OF CENTRAL STATES MANUFACTURING, INC. 'CENTRAL-LOC PANEL' FLORIDA BUILDING CODE 5TH EDITION (2014) FLORIDA PRODUCT APPROVAL FL 14016.2-R2 STRUCTURAL COMPONENTS ROOF DECK Prepared For:

More information

BXUV.U415 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263

BXUV.U415 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263 Page 1 of 7 Page Bottom BXUV.U415 Fire Resistance Ratings - ANSI/UL 263 Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - ANSI/UL 263 Design No. U415 July 30,

More information

Design No. M507. Design No. M507

Design No. M507. Design No. M507 1 of 5 3/17/2015 6:22 PM Design No. M507 BXUV.M507 Fire Resistance Ratings - ANSI/UL 263 Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted

More information

Page 2 of 5 1. Flooring Systems The flooring system shall consist of one of the following: System No. 1 Subflooring Nom 23/32 in. thick wood structura

Page 2 of 5 1. Flooring Systems The flooring system shall consist of one of the following: System No. 1 Subflooring Nom 23/32 in. thick wood structura Page 1 of 5 Page Bottom Design No. L577 BXUV.L577 Fire-resistance Ratings - ANSI/UL 263 Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases

More information

Design No. L565. Design No. L565

Design No. L565. Design No. L565 1 of 5 3/17/2015 6:18 PM Design No. L565 BXUV.L565 Fire Resistance Ratings - ANSI/UL 263 Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted

More information

FIRESTOP TECHNICAL PACK TEL: (888) 721-SEAL (7325) FAX: (888) 921-SEAL (7325)

FIRESTOP TECHNICAL PACK TEL: (888) 721-SEAL (7325) FAX: (888) 921-SEAL (7325) FIRESTOP TECHNICAL PACK FIRESEAL 814 Acrylic Intumescent Caulk Polymer Adhesives Sealant Systems, Inc. 501 Garrett Morris Parkway Mineral Wells, TX 76067 TEL: (888) 721-SEAL (7325) FAX: (888) 921-SEAL

More information

SUBMITTAL INDEX. Product Datasheets: Product Approvals:

SUBMITTAL INDEX. Product Datasheets: Product Approvals: Product Datasheets: HFP Pro Series Sleeve RevA HFP CD Plates RevA HFP Sleeve Extenions RevA HFP Water Dam RevA HFP Water Module RevA HFP Hollow Sleeve RevB HFP Cable Line Set RevA HFP Closet Flange RevA

More information

Design No. D929 February 07, Restrained Assembly Rating 1, 1-1/2, 2, or 3 Hr. (See Items 1, 5, 9, 10, 14)

Design No. D929 February 07, Restrained Assembly Rating 1, 1-1/2, 2, or 3 Hr. (See Items 1, 5, 9, 10, 14) Design No. D929 February 07, 2003 Restrained Assembly Rating 1, 1-1/2, 2, or 3 Hr (See Items 1, 5, 9, 10, 14) Unrestrained Assembly Ratings 0 Hr (See Item 4 & 5) Unrestrained Beam Ratings 1, 1-1/2 or 2

More information

System No. HW-D-0548

System No. HW-D-0548 System No. Ì73hwdÇ%P+11bÎ ANSI/UL2079 Assembly atings - 1 and 2 Hr (See Item 2) Maximum Joint Width - 3/4, 1 or 1-1/2 In. (See Item 3) Class II Movement Capabilities - 50 or 100 %Compression or Extension

More information

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079) WET FILM ± 7.5 ± 5 Design No. CEJ 27 P (HI/JS 20-05) Table. CONCRETE FLOOR ASSEMBLY: Max. two-hour rated concrete floor assembly made from either lightweight or normal weight concrete with a density of 00-50 pcf, with a

More information

Duct Wrap Flexible Wraps

Duct Wrap Flexible Wraps Design No. 3MU/ 60-01 December 23, 2010 VENTILATION DUCT PROTECTION 3M Company 3M Fire Barrier Duct Wraps: 615 and 615+ 3M Fire Barrier Sealants: Water-Tight 1000-NS Silicone, Water-Tight 1003-SL Silicone

More information

BXUV.U411. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

BXUV.U411. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263 Page Bottom BXUV.U411 Fire Resistance Ratings - ANSI/UL 263 Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements

More information

The System U.S. Patent No. 5,913,788

The System U.S. Patent No. 5,913,788 The System U.S. Patent No. 5,913,788 UL System No. HW-D-0027 2 Hour Rated Assembly (Metal Decking) UL System No. HW-D-0028 1 Hour Rated Assembly (Metal Decking) UL System No. HW-D-0208 1 Hour Rated Assembly

More information

CAJ. Combos. C-AJ of 5. Through Penetrations Series. Concrete. 3Fire Protection Products

CAJ. Combos. C-AJ of 5. Through Penetrations Series. Concrete. 3Fire Protection Products System No. C-AJ-8073 September 07, 2004 F Rating 2 Hr T Ratings 0, 3/4 and 2 Hr C-AJ-8073 1 of 5 1. Floor or Wall Assembly Min 4-1/2 in. thick reinforced normal weight (140-150 pcf) concrete. Wall may

More information

System No. C-AJ-8133

System No. C-AJ-8133 System No. C-AJ-8133 March 09, 2011 F Ratings - 1, 1-1/2, 2 and 3 Hr (See Item 2) T Ratings - 0, 1/2, 3/4, 1, 1-1/2, 2 and 3 Hr (See Item 2) 1. Floor or Wall Assembly Min 4-1/2 in. (114 mm) thick reinforced

More information

Design No. D923 December 10, Restrained Assembly Ratings 3/4, 1, 1-1/2, 2 or 3 Hr. (See Items 2, 7, 8, 9 and 12)

Design No. D923 December 10, Restrained Assembly Ratings 3/4, 1, 1-1/2, 2 or 3 Hr. (See Items 2, 7, 8, 9 and 12) Design No. D923 December 10, 2001 Restrained Assembly Ratings 3/4, 1, 1-1/2, 2 or 3 Hr (See Items 2, 7, 8, 9 and 12) Unrestrained Assembly Rating 0 Hr (See Item 4) Unrestrained Beam Ratings 1, 1-1/2, 2

More information

SLOTTED STUD WIND-LOAD & NON-LOAD BEARING DEFLECTION WALL SYSTEM. U.L. FIRE RATED Head-of-Wall Joint Systems

SLOTTED STUD WIND-LOAD & NON-LOAD BEARING DEFLECTION WALL SYSTEM. U.L. FIRE RATED Head-of-Wall Joint Systems SLOTTED STUD WIND-LOAD & NON-LOAD BEARING DEFLECTION WALL SYSTEM U.L. FIRE RATED Head-of-Wall Joint Systems 1-800-275-2279 STEELER INC. SLOTTED STUD 1-800-275-2279 The STEELER SLOTTED STUD is an innovative

More information

System No. HW-D-0119

System No. HW-D-0119 System No. HW-D-0119 August 03, 2007 Assembly Rating 1, 2 and 3 Hr (See Item 2) Nominal Joint Width 1 In. Class II and III Movement Capabilities 100% Compression or Extension 1. Floor Assembly The fire-rated

More information

Subject: NRCA MRCA Joint Technical Bulletin. Date: January 2008 NOT COMPROMISE.

Subject: NRCA MRCA Joint Technical Bulletin. Date: January 2008 NOT COMPROMISE. Roofing No. 3001 NRCA MRCA Joint Technical Bulletin Attached is a copy of the NRCA/MRCA Joint Technical Bulletin which was presented at the 1987 MRCA Convention. This document is entitled, In-Service R-Values

More information

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1 FIRESTOP JOINT SPRAY CFS-SP WB SILICONE JOINT SPRAY CFS-SP SIL F-RATING 2-HR. 2-HR. T-RATING -HR. -HR. APPLICATION THICKNESS PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table /8" WET FILM (/6"

More information

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848 LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848 International Fireproof Technology Inc. 17528 Von Karman Avenue Irvine, CA 92614 This report is for the exclusive

More information

Firestopping Submittal Package

Firestopping Submittal Package Firestopping Submittal Package Project: Architect: General Contractor: Installation Contractor: Distributor (and Contact): Manufacturer's Representative: Rectorseal - Technical Services Ph (713) 263-8001

More information

Through-Fastener Panel UL Listing documentation

Through-Fastener Panel UL Listing documentation Through-Fastener Panel UL Listing documentation Class-4 Impact Rating Class-90 Fire Rating Tensile Strength: Grade 80/E Coil Thickness Range for 29 ga.: 0.0142 0.015 Coil Thickness Range for 26 ga.: 0.0182

More information

PARKING PLAZA MEXICO COVERED GAS PUMP ISLAND PARKING BUS PARKING AREA. The Evans Group COVERD AREA TACO STAND COVERD AREA AREA FREEZER EXIT EXIT

PARKING PLAZA MEXICO COVERED GAS PUMP ISLAND PARKING BUS PARKING AREA. The Evans Group COVERD AREA TACO STAND COVERD AREA AREA FREEZER EXIT EXIT OFFICE FUEL ISLAND ATTENDANTS OFFICE GAS PUMP ISLAND BUS SIGNAGE AND 6'-0" WALL TACO STAND COVERED RESTROOMS RESTROOMS MARKET TACO STAND PLAZA MEXICO COVERED FREEZER GAS PUMP ISLAND BUS FUEL ISLAND ATTENDANTS

More information

System No. C-AJ-8048

System No. C-AJ-8048 System No. C-AJ-8048 F Rating - 2 Hr T Ratings - 0, 1/2, 3/4, 1 and 1-1/2 Hr (See Item 2) L Rating At Ambient Less Than 1 CFM / Sq. Ft. L Rating At 400 F 5 CFM / Sq. Ft. System No. C-AJ-8048 System No.

More information

BXUV.L576 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263

BXUV.L576 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263 Page 1 of 7 Page Bottom BXUV.L576 Fire Resistance Ratings - ANSI/UL 263 Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - ANSI/UL 263 Design No. L576 August 15,

More information

Design No. P922 September 26, Restrained Assembly Rating 1, 1-1/2 or 2 Hr (See Items 6, 7) Unrestrained Assembly Rating 0 Hr (See Item 6)

Design No. P922 September 26, Restrained Assembly Rating 1, 1-1/2 or 2 Hr (See Items 6, 7) Unrestrained Assembly Rating 0 Hr (See Item 6) Design No. P922 September 26, 2003 Restrained Assembly Rating 1, 1-1/2 or 2 Hr (See Items 6, 7) Unrestrained Assembly Rating 0 Hr (See Item 6) Unrestrained Beam Rating 1, 1-1/2 or 2 Hr (See Item 7) 1.

More information

BXUV.L548 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263

BXUV.L548 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263 Page 1 of 8 Page Bottom BXUV.L548 Fire Resistance Ratings - ANSI/UL 263 Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - ANSI/UL 263 Design No. L548 December

More information

FIRESTOP SUBMITTAL PACKAGE

FIRESTOP SUBMITTAL PACKAGE FIESTOP SUBMITTAL PACKAGE Head of Wall Firestop Submittal POJECT: DATE: September 28, 2011 SUBMITTED BY: Brent Johnson STI Firestop 415-515-3767 bjohnson@stifirestop.com 200 Evans Way Somerville, NJ 08876

More information

System No. C-AJ-8096

System No. C-AJ-8096 F Rating -- Hr T Rating -- 0, / and Hr (See Item ) B B E E G G F F A A C C D D 4B 4A SECTION A-A SECTION B-B July 0, 005 Page: of 5 F Rating -- Hr T Rating -- 0, / and Hr (See Item ) B A SECTION C-C SECTION

More information

CONNECTOR B L O C K S H E A R. Design for Composite Structural Action BLOCK SHEAR CONNECTOR APPLICATION. Airspace

CONNECTOR B L O C K S H E A R. Design for Composite Structural Action BLOCK SHEAR CONNECTOR APPLICATION. Airspace B L O C K S H E A R CONNECTOR BLOCK SHEAR CONNECTOR APPLICATION Airspace Design for Composite Structural Action Exterior ashlar-type masonry veneer, typically of clay brick or concrete block masonry, are

More information

CEYDC.R25563 Nonmetallic Plumbing System Components Listed for Fire Resistance

CEYDC.R25563 Nonmetallic Plumbing System Components Listed for Fire Resistance INFO 33, page 1 CEYDC.R25563 Nonmetallic Plumbing System Components Listed for Fire Resistance HEATLINK GROUP INC R25563 4603E 13TH ST NE CALGARY, AB T2E 6M3 CANADA Types Purelink PEXa, Heatlink PEXa and

More information

Hebel Fire Walls Masonry solutions to increase speed of construction and performance.

Hebel Fire Walls Masonry solutions to increase speed of construction and performance. Hebel Fire Walls Masonry solutions to increase speed of construction and performance. Hebel block walls have a 4 hour fire rating. Visit www.buildwithhebel.com to view the ASTM E119 test. 4-Hour Fire Rating

More information

BXUV.L521 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263

BXUV.L521 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263 Page 1 of 8 Page Bottom BXUV.L521 Fire Resistance Ratings - ANSI/UL 263 Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - ANSI/UL 263 Design No. L521 November

More information

Fire Protection Products. Firestop Submittal Package FIP 1-Step Firestop Foam. Electrical Trade

Fire Protection Products. Firestop Submittal Package FIP 1-Step Firestop Foam. Electrical Trade Fire Protection Products Firestop Submittal Package FIP 1-Step Firestop Foam Electrical Trade Manufacturer: Fire Protection Products Ryan Fenstermaker 732.921.1503 rfenstermaker@mmm.com Electrical Products

More information

SUBMITTAL INDEX. Product Datasheets: Product Approvals:

SUBMITTAL INDEX. Product Datasheets: Product Approvals: Product Datasheets: SUBMITTAL INDEX HF Corrugated Deck Cast In Place Sleeve Non Met HF Corrugated Deck Optional Pipe Sleeve Non Met HF Corrugated Deck Seal Sleeve Non Met HF Optional Pipe Size Sleeve Non

More information

VITALink 2-Hour Fire Resistive Circuit Integrity Cable with Hose Stream

VITALink 2-Hour Fire Resistive Circuit Integrity Cable with Hose Stream VITALink 2-Hour Fire Resistive Circuit Integrity Cable with Hose Stream INSTALLATION GUIDE For 18,16,14 & 12 AWG 2-Hour Rated Fire Resistive Applications UL 105 C Listed Type FPLR-CI-LS, CMR-CI-LS, CL3R-CI-LS

More information

Design No. P921 April 16, Restrained Assembly Rating 1, 1-1/2 or 2 Hr (See Items 4, 6, 7 and 9) Unrestrained Assembly Rating 0 Hr (See Item 7)

Design No. P921 April 16, Restrained Assembly Rating 1, 1-1/2 or 2 Hr (See Items 4, 6, 7 and 9) Unrestrained Assembly Rating 0 Hr (See Item 7) Design No. P921 April 16, 2003 Restrained Assembly Rating 1, 1-1/2 or 2 Hr (See Items 4, 6, 7 and 9) Unrestrained Assembly Rating 0 Hr (See Item 7) Unrestrained Beam Rating 1, 1-1/2 or 2 Hr (See Items

More information

Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19

Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19 Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19 Page 1 or 8 APPLICATION This fi re damper is intended to restrict the passage of fl ame. The standard installation requires that the

More information

BXUV.U465. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

BXUV.U465. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263 Page Bottom BXUV.U465 Fire Resistance Ratings - ANSI/UL 263 Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements

More information

SECTION NON--STRUCTURAL METAL FRAMING

SECTION NON--STRUCTURAL METAL FRAMING The Collective Voice of America s Steel Framing Industry The Steel Framing Industry Association (SFIA) is dedicated to expanding the market for cold-formed steel in construction through programs and initiatives

More information

I-STUD Shaftwall System

I-STUD Shaftwall System I-STUD Shaftwall System Summit Tower I-Stud and CertainTeed Shaftliner TM MILL CERTIFIED Steel-Con 00% GALVANIZED Steel Construction Systems UL Evaluation Report No. ER3660-02 Intertek The I-Stud is approved

More information

LLOYD INDUSTRIES INC. DAMPER INSTALLATION INSTRUCTIONS

LLOYD INDUSTRIES INC.   DAMPER INSTALLATION INSTRUCTIONS Installation and Maintenance Instructions 1-1/2 Hour Rated, UL Classified model 75 fire dampers For use in fire barriers with ratings of less than 3 hours INSPECTION 1. Inspect for shipping damage. 2.

More information

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 11

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 11 07 21 16 Blanket Insulation Page 1 of 11 Unifrax I LLC Design No. UNI/BI 120-14 FIRE RESISTANT GREASE DUCT FyreWrap Elite 1.5 Duct Insulation ASTM E 2336-16 and ICC-ES Acceptance Criteria for Grease Duct

More information

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 17

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 17 07 21 16 Blanket Insulation Page 1 of 17 Design Number UNI/BI 120-03 FIRE RESISTANT GREASE DUCT Unifrax I LLC FyreWrap Elite 1.5 Duct Insulation CAN/ULC S144 Fire Resistance Rating 2 hours Fire Inside

More information

RATING: Consult factory for availability Consult factory for availability

RATING: Consult factory for availability Consult factory for availability DYNAMIC FIRE DAMPER MODELS: 75A-DY (1-1/2 HR rating) APPLICATION The model 75A-DY is constructed with standard constructiongalvanized steel. 75A-DY is 1-1/2 hour UL rated dynamic damper for use in HVAC

More information

I-STUD Shaftwall System

I-STUD Shaftwall System I-STUD Shaftwall System Summit Tower Spokane, WA I-Stud and CertainTeed Shaftliner MILL CERTIFIED 00% GALVANIZED UL Evaluation Report No. ER3660-02 Intertek SCAFCO I-Stud is approved with the following

More information

Design No. D927 December 10, Restrained Assembly Ratings 3/4, 1, 1-1/2, 2 & 3 Hr. (See Items 1, 6, 7, 8 & 11) Unrestrained Assembly Ratings 0 Hr

Design No. D927 December 10, Restrained Assembly Ratings 3/4, 1, 1-1/2, 2 & 3 Hr. (See Items 1, 6, 7, 8 & 11) Unrestrained Assembly Ratings 0 Hr Design No. D927 December 10, 2001 Ratings 3/4, 1, 1-1/2, 2 & 3 Hr (See Items 1, 6, 7, 8 & 11) Ratings 0 Hr (See Item 3) Beam Ratings 1, 1-1/2, 2 & 3 Hr (See Items 4, 4A, 7 & 11) Supports W8x28 min size

More information

ENGINEERING EVALUATION

ENGINEERING EVALUATION ENGINEERING EVALUATION REPORT NUMBER: 318773MID-003 ORIGINAL ISSUE DATE: August 28, 2009 REVISION AND DATE: Original EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562 RENDERED TO Hanchett

More information

A. Product Data: Identify thermal conductivity, thickness, and jackets (both factory and field applied, if any), for each type of product indicated.

A. Product Data: Identify thermal conductivity, thickness, and jackets (both factory and field applied, if any), for each type of product indicated. SECTION 23 07 13 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Design No. P214 December 09, Restrained Assembly Rating 1 Hr. Unrestrained Assembly Rating 1 Hr. Unrestrained Beam Rating 1 Hr.

Design No. P214 December 09, Restrained Assembly Rating 1 Hr. Unrestrained Assembly Rating 1 Hr. Unrestrained Beam Rating 1 Hr. Design No. P214 December 09, 2002 Restrained Assembly Rating 1 Hr. Unrestrained Assembly Rating 1 Hr. Unrestrained Beam Rating 1 Hr. Beam W8 x 17, min size. Joist girders-(not shown)-20 in. min depth and

More information

Expansion Joint Covers

Expansion Joint Covers Expansion Joint Covers 07 95 00 (079513) PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions, Supplementary Conditions and Division-1

More information

NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System

NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System -Hour Wall System The -hour Wall System is a -hour fire wall consisting of two layers of in. (. mm) shaftliner panels friction-fit between in. (0. mm) light-gauge steel H-Studs and a layer of /" Fire-Shield

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 260548 - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Isolation pads. 2. Spring isolators. 3. Restrained spring isolators. 4. Channel

More information

A. Types of lightgauge metal framing units include the following: 1. C-shaped structural steel studs Uniform Building Code.

A. Types of lightgauge metal framing units include the following: 1. C-shaped structural steel studs Uniform Building Code. SECTION 05400 COLD-FORMED METAL FRAMING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Cavity ShAftwall System

Cavity ShAftwall System 09 9 00/NGC Cavity shaftwall systems are non-load-bearing, -hour to -hour, fire-rated partitions constructed from one side used to enclose elevator shafts, stairs and mechanical shafts where the design

More information

St. Monica Food Pantry

St. Monica Food Pantry St. Monica Food Pantry 07 8400-1 SECTION 07 8400 - FIRESTOPPING PART 1 - GENERAL 1.1 SUMMARY: A. Related work: 1. Concrete. 2. Mortar and grout. 3. Brick masonry. 4. Concrete unit masonry. 5. Structural

More information

2.5" Min. Stud or Runner. 1.5" Mineral Fiber Blanket in Cavity, If Required. Wallboard. Retaining Angle. 1" Min. Damper Sleeve on 10" centers.

2.5 Min. Stud or Runner. 1.5 Mineral Fiber Blanket in Cavity, If Required. Wallboard. Retaining Angle. 1 Min. Damper Sleeve on 10 centers. General Notes: When UL is referred to in this document, it represents UL/ULC. This installation instruction applies to Fire s (static, dynamic, curtain, single and multi-blade types) mounted in the plane

More information

Design No. D925 December 10, Restrained Assembly Ratings 3/4, 1, 1-1/2, 2 or 3 Hr. (See Items 1, 6 and 10)

Design No. D925 December 10, Restrained Assembly Ratings 3/4, 1, 1-1/2, 2 or 3 Hr. (See Items 1, 6 and 10) Design No. D925 December 10, 2003 s 3/4, 1, 1-1/2, 2 or 3 (See Items 1, 6 and 10) 0 (See Items 3, 4, 4A and 10) s 1, 1-1/2, 2, 3 and 4 (See Items 4, 4A and 10) Supports W8x28 or W12x16 min size steel beam

More information

SECTION CEMENTITIOUS WOOD FIBER DECKS

SECTION CEMENTITIOUS WOOD FIBER DECKS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 03 51 13 CEMENTITIOUS WOOD FIBER DECKS SPEC WRITE NOTES: 1. Delete between // // if not applicable to project. 2. Also delete any other item or paragraph not applicable

More information

A. Access doors and frames are part of an access door and frame allowance.

A. Access doors and frames are part of an access door and frame allowance. SECTION 08 31 13 ACCESS DOORS AND FRAMES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Expansion Joint Covers (079513)

Expansion Joint Covers (079513) Expansion Joint Covers 07 95 00 (079513) PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions, Supplementary Conditions and Division-1

More information

ICC-ES Evaluation Report Reissued May 1, 2010 This report is subject to re-examination in two years.

ICC-ES Evaluation Report Reissued May 1, 2010 This report is subject to re-examination in two years. ICC-ES Evaluation Report ESR-1255 Reissued May 1, 2010 This report is subject to re-examination in two years. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

Installation. Resilmount A237R. Installation Instructions. Furring channel sound isolation clip

Installation. Resilmount A237R. Installation Instructions. Furring channel sound isolation clip Resilmount A237R Furring channel sound isolation clip Installation Instructions Another Quality Building Product Installation A237R SPECIFICATIONS Width: 1-3/8 eight (including rubber): 1-1/16 Length:

More information

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System 0 00/NGC NATIONAL GYPSUM COMPANY -Hour Wall System The -Hour is a -hour fire wall consisting of in. (0. mm) light-gauge steel H-Studs that secure two layers of in. (. mm) shaftliner panels friction-fit

More information

Concrete Inserts. B Adjustable Metal Deck Ceiling Bolt

Concrete Inserts. B Adjustable Metal Deck Ceiling Bolt B3019 - Adjustable Metal Deck Ceiling Bolt Size Range: 3 /8"-16 thru 3 /4"-10 rod Function: For use in metal deck formed concrete to attach hanger rods. Allows for pre-positioning of hanger rods in poured

More information

Design No. P907 October 31, Restrained Assembly Rating 1, 1-1/2 or 2 Hr. (See Items 5 and 6) Unrestrained Assembly Rating 0 Hr.

Design No. P907 October 31, Restrained Assembly Rating 1, 1-1/2 or 2 Hr. (See Items 5 and 6) Unrestrained Assembly Rating 0 Hr. Design No. P907 October 31, 2003 Rating 1, 1-1/2 or 2 Hr. (See Items 5 and 6) Rating 0 Hr. (See Item 5) Rating 1, 1-1/2 or 2 Hr. (See Item 6) 1. Steel Supports W6x16, W8x10, W8x18 or W8x28 min size s or

More information

System No. W-J-4050 ANSI/UL1479 (ASTM E814) CAN/ULC S115 4F2 4E. Reproduced by HILTI, Inc. Courtesy of. Underwriters Laboratories, Inc.

System No. W-J-4050 ANSI/UL1479 (ASTM E814) CAN/ULC S115 4F2 4E. Reproduced by HILTI, Inc. Courtesy of. Underwriters Laboratories, Inc. CLSS to UL 1479 and CN/ULC-S115 NSI/UL1479 (STM E814) CN/ULC S115 4 4F 4F1 4F 4F1 4 CONFIGURTION SECTION - Page: 1 of 5 CLSS to UL 1479 and CN/ULC-S115 NSI/UL1479 (STM E814) CN/ULC S115 4F 1 4G 4 4H CONFIGURTION

More information

ADVANCE METAL INDUSTRIES L.L.C.

ADVANCE METAL INDUSTRIES L.L.C. ADVANCE METAL INDUSTRIES L.L.C. Copyright reserved for ADVANCE METAL ''Due to continuos progress and product improvement, ADVANCE METAL reserves the right to make changes without notice'' DISCLAIMER OF

More information

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers. SECTION 05 31 13 STEEL FLOOR DECKING PART 1 - GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the contract, including General and Supplementary Conditions and Division 01 - Specification

More information

Fig Beam Clamp Retaining Strap (B-Line B3367)

Fig Beam Clamp Retaining Strap (B-Line B3367) Fig. 69 - Beam Clamp Retaining Strap (B-Line B3367) Size Range: 3 /8"-16 thru 3 /4"-10 rod 4 (101.6mm) thru 16 (406.4mm) lengths Note: longer lengths are available consult factory Material: Pre-Galvanized

More information

Shaft Wall Solutions for Wood-Frame Structures. Ricky McLain, PE, SE WoodWorks Wood Products Council Boston & Waltham Workshops, December 6 & 7, 2017

Shaft Wall Solutions for Wood-Frame Structures. Ricky McLain, PE, SE WoodWorks Wood Products Council Boston & Waltham Workshops, December 6 & 7, 2017 Shaft Wall Solutions for Wood-Frame Structures Ricky McLain, PE, SE WoodWorks Wood Products Council Boston & Waltham Workshops, December 6 & 7, 2017 Shaft Walls Shaft Walls Form Shaft Enclosures The purpose

More information

Introducing NEW. Taking on joint pain, one joint cover at a time.

Introducing NEW. Taking on joint pain, one joint cover at a time. Introducing NEW Taking on joint pain, one joint cover at a time. C/S Restofit Joint Systems are ready to tackle your worst expansion joint areas. If these pictures look familiar, give us a call. (or send

More information

installation instructions Combination Fire & Smoke Damper

installation instructions Combination Fire & Smoke Damper Combination Fire & Smoke Damper Sleeve Fire Rated Partition Retaining Angle Combination Fire & Smoke Damper Actuator General Notes: Combination Fire & Smoke Dampers are approved for use in static or dynamic

More information

SECTION COMPOSITE METAL DECKING

SECTION COMPOSITE METAL DECKING PART 1 GENERAL 1.1 DESCRIPTION SECTION 05 36 00 1. Use this section only for NCA projects. 2. Delete between // ---- // if not applicable to project. Also delete any other item or paragraph not applicable

More information

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance Pei Evaluation Service is an accredited ISO Standard 17065 Product Certifier, accredited by the IAS. This Assembly Evaluation Report represents a product that Pei ES has Evaluated. This Assembly Evaluation

More information

SECTION TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS. A. Solid composite phenolic toilet compartments and urinal screens.

SECTION TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS. A. Solid composite phenolic toilet compartments and urinal screens. SECTION 102113 TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Solid composite phenolic toilet compartments and urinal screens. 1.02 RELATED SECTIONS

More information

Special Applications. Dorn Equipment, Corporation 27 Upham Street Melrose, MA Phone: Fax:

Special Applications. Dorn Equipment, Corporation 27 Upham Street Melrose, MA Phone: Fax: Special Applications Outdoor Protection When using the FIRSTO units outdoors, or wherever vapor or moisture barrier is needed, an application of FIWA sealant is used. The sealant should be applied to any

More information

Construction Details 5-37

Construction Details 5-37 5-37 5-38 Construction Details 5-39 5-40 Construction Details 5-41 5-42 Construction Details 5-43 5-44 Construction Details 5-45 5-46 Construction Details 5-47 5-48 Construction Details 5-49 RING ANCHOR

More information

SPECIFICATIONS Aluminum Stair Nosing - Bull Nosing

SPECIFICATIONS Aluminum Stair Nosing - Bull Nosing 2009 IBC/IFC Aluminum Stair Tread Aluminum Stair Nosing - Bull Nosing ITEM NO: BPL307BNA Width 2.169, Specify Custom Length up to 12 Anti-skid stair tread marking, intended for indoor and outdoor. Apply

More information

Design No. P725 December 10, Restrained Assembly Rating-1, 1-1/2 or 2 H (See Item 8) Unrestrained Assembly Rating-1, 1-1/2 or 2 H (See Item 8)

Design No. P725 December 10, Restrained Assembly Rating-1, 1-1/2 or 2 H (See Item 8) Unrestrained Assembly Rating-1, 1-1/2 or 2 H (See Item 8) Design No. P725 December 10, 2003 Restrained Rating-1, 1-1/2 or 2 H (See Item 8) Rating-1, 1-1/2 or 2 H (See Item 8) Rating-1, 1-1/2 or 2 H (See Item 8) 1. Steel Supports W8X28 steel beam min size, 10K1

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 26 05 48 - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Isolation pads. 2. Spring isolators. 3. Restrained spring isolators. 4. Channel

More information

MASONRY ANCHORS AND CONNECTORS May 6, 2014

MASONRY ANCHORS AND CONNECTORS May 6, 2014 Page - 1 This section includes specification text to assist in describing a variety of masonry anchors, connectors, and accessories intended for masonry construction. This document contains prepared master

More information

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT SECTION 230548 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Elastomeric Isolation pads. 2. Elastomeric Isolation mounts. 3. [Freestanding] [Restrained] [Freestanding and restrained]

More information

SECTION HANGERS AND SUPPORTS PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

SECTION HANGERS AND SUPPORTS PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section. 1.01 RELATED DOCUMENTS SECTION 15060 HANGERS AND SUPPORTS PART 1 - GENERAL A. Drawings and Division 1 Specification Sections, apply to this Section. 1.02 SUMMARY A. This Section includes hangers and supports

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT SECTION 230548 - VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 092216 - NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

CONNECTOR S T U D S H E A R. Design for Composite Structural Action STUD SHEAR CONNECTOR APPLICATION

CONNECTOR S T U D S H E A R. Design for Composite Structural Action STUD SHEAR CONNECTOR APPLICATION S T U D S H E A R CONNECTOR STUD SHEAR CONNECTOR APPLICATION Design for Composite Structural Action Exterior ashlar-type masonry veneer, typically of clay brick or concrete block masonry, are commonly

More information