SECTION INSTALLATION AND/OR REPLACEMENT OF MASONRY UNITS AND REPOINTING

Size: px
Start display at page:

Download "SECTION INSTALLATION AND/OR REPLACEMENT OF MASONRY UNITS AND REPOINTING"

Transcription

1 SECTION INSTALLATION AND/OR REPLACEMENT OF MASONRY UNITS AND REPOINTING PART I GENERAL 1.1 SUMMARY A. Provide installation of new or replacement of masonry units and/or repointing of masonry units where shown on Drawings or as instructed, as specified herein, and/or as needed for a complete and proper installation. Furnish all labor, materials, equipment and services necessary for a complete and proper installation to highest industry standards. B. Work includes but is not limited to: 1.2 RELATED WORK 1.3 SUBMITTALS 1. Installation of new or used brick masonry units. 2. Repointing to repair deteriorated or missing mortar. Masonry Repairs are to be limited to areas directly related to the proper installation of roof flashing only. 1. Section Miscellaneous Flashing and Sheet Metal 2. Section Sealants A. Submit manufacturer's product data for each type of masonry unit, accessory, and other manufactured products. Include certifications and test reports from a testing laboratory that is independent of the manufacturer, indicating that each type of unit complies with the specified requirements. Product data shall be furnished for approval by the Architect prior to use. B. Install sample area of repointing and brick masonry, which shall be allowed to cure 7 days for inspection by Owner or Architect. Submit sample of brick units to be used in color, blend texture and size. Sample area must be approved before Contractor may proceed with balance of repointing. 1.4 QUALITY ASSURANCE A. Use adequate numbers of skilled workmen who are thoroughly trained and experienced in the necessary crafts and who are completely familiar with the specified requirements and the methods needed for proper performance of the work of this Section. If repointing, use only qualified and experienced repointing craftsmen. If moisture penetration problem exists, do not proceed with repointing until source of moisture penetration has been determined and action has been taken to correct both the visible effect and moisture penetration

2 B. Do not install masonry if temperature is less than forty degrees or is expected to drop below forty degrees within a twenty-four hour time period. C. In addition to complying with all pertinent codes and regulations,comply with all recommendations and Technical Notes on Brick Construction published by Brick Institute of America, most current edition. PART 2 - PRODUCTS 2.1 BRICK A. Acceptable products: 2.2 MORTAR 1. Provide brick to match size, color, blend, face, and texture of existing structure. Brick shall be clean and in sound condition. Cull out any chipped, soft or unsound bricks. Obtain approval of Architect and Owner prior to proceeding. 2. Face brick shall comply with ASTM Designation C216 with a rating of no efflorescence when tested according to ASTM C67. A. Portland cement: Comply with ASTM C 150, type I. B. Masonry cement: Comply with ASTM C 91. C. Lime: Provide hydrated lime, Type S complying with ASTM C207. D. Aggregate: Provide clean, well graded aggregate free from injurious amounts of dust, lumps, shale, alkali, surface coatings, and organic matter, and complying with ASTM C144. Note: Select sand for color to match existing mortar. E. Admixtures: Do not use admixtures unless specifically approved in advance by the Architect. F. Water: Provide water free from deleterious amounts of acids, alkalis, and organic materials. G. Color: Match existing original mortar color of structure, exactly. H. Joint type: Match existing, exactly. I. Mixture: Comply with Proportion Specifications in accordance with ASTM C 270 BIA Designation M1-72. (See Brick Institute of America, Technical Notes on Brick Construction. ) Release 8 Revision II, Released November 1989 and 8A Revised, Released September

3 PART 3 - EXECUTION 3.1 MORTAR A. Installation Repointing: 1. If required: Clean walls, using moderate pressure, hot water and/or steam, without cleaning solutions or grit. Pressure should be approximately psi and directed at the masonry at an angle of not more than 30 degrees from the wall surface. If efflorescence exists, contact Architect for method of removal prior to proceeding. When spot repointing, pressure washing may not be required; consult Architect prior to initiating work. 2. Identify areas to be repointed as specified by Architect, Owner or Owner s Representative. 3. Install sample area: See 1.3B this Section. 4. The old mortar should be cut out, by means of hand chisels and mash hammers or by small power chisels (either pneumatic or a thin diamond blade) to a uniform depth of 2 to 2 1/2 times the width of the joint or until sound mortar is reached. Care must be taken not to damage the brick edges when cutting vertical joints. All dust and debris must be removed from the joint by brushing, blowing with air or rinsing with water. 5. Joints to be repointed should be dampened. To ensure good bond, brick must absorb all surface water. No standing water should be present. 6. Pack mortar tightly in layer ¼ maximum. 7. Layers to be thumbprint hard before applying successive layer. 8. Tool to match the original profile after the last layer of mortar is thumb print hard. B. Procedure for Mixing Mortar Note: The mixed mortar shall be of consistency to be molded into a ball by hand. A skilled brick layer should test mortar for feel releasing or increasing sand or water as needed. Mortar shall be easy working. 1. Provide mortar type N in accordance with ASTM C270 or match existing throughout structure. Consult Architect prior to proceeding with the work., 2. Proportions: As per Specifications of the Brick Institute of America, Technical Notes on Brick Construction, release 7F, 28, 8 A + B and 11E, revised January, 1987, July 1986, November 1989, September 1988, and June

4 3. Repointing mortar should be prehydrated to reduce excessive shrinkage. Prehydrate as per Specifications of the Brick Institute of America, Technical Notes on BrickConstruction, release 7F, 28, 8 A + B, and 11E, revised January, 1987, July 1986, November 1989, September 1988, and June A sample or samples of mortar shall be mixed dry by hand mixing and compared with the existing mortar sample for color, texture and amount and size of sand, aggregate, or other materials, i.e. oyster shells or horse hair. 5. The mixed mortar shall be of a consistency to be molded into a ball by hand. 6. Mortar shall be mixed with maximum amount of water to produce workable consistency. 7. Mixed mortar shall be permitted to stand for not less than one -half hour, nor more than one and one-half hours for pre-hydration. 8. All mortar shall be used within one-half (½) hour of its initial mixing. Re-tempering of the mortar (adding of additional water to the mix) to replace evaporated water shall not be permitted. 9. Upon completion, clean surfaces of masonry as required for proper application of the specified finishes. 3.2 INSTALLATION OF BRICK MASONRY UNITS A. Examine the areas and conditions under which work of this Section will be performed. Correct conditions detrimental to timely and proper completion of the work. Do not proceed until unsatisfactory conditions are corrected. B. Comply with Section 2.1. C. Installation: 1. Wetting of bricks: a. Pre-wet only if IRA is greater than thirty grams per minute per thirty square inch area. Wetting shall be performed no more then 24 or less than 12 hours prior to laying brick. b. Provide sufficient dampness so that mortar will remain plastic enough to permit the brick to be leveled and plumbed immediately after being laid, without destroying the bond. 2. Laying: a. All work shall be in compliance with the Specifications of the Brick Institute of America, "Technical Notes on Brick Constrution," most recent edition

5 b. Unless otherwise indicated on the Drawings, make the brickwork plumb, level, and true to line, with square angles and corners. Center brick in opening and press in place. c. Use line blocks whenever possible. When it is absolutely necessary to use a line pin, fill the hole immediately after the pin is withdrawn. d. Use only bricks that are clean and free from dust and other foreign matter. e. Lay in running bond unless otherwise shown on the Drawings or specifically indicated by Architect or Owner. f. Bed Joints: (1) Bevel all bed joints, sloping toward the center of the wall in such a manner that the bed joints will be completely filled when the brick is finally brought into line. (2) Do not furrow bed joints. (3) Lay all brick units within 1 minute of placing mortar (4) Avoid fins of bed joints protruding into cavity space. (a) (b) If they occur, leave in place if not projecting more than the bed joint thickness. Do not, in any case, cut off and drop into cavity space. (5) Lay masonry units within one minute of preparing bed joints. g. Head joints: (1) Fill completely to ensure full joint. (2) Butter end of brick prior to installation to ensure full joint. h. Do not move or shift bricks. If moved or shifted, review and lay again in fresh mortar. i. Immediately remove mortar from areas where they are not scheduled to be placed

6 3.3 JOINERY A. General: 1. Cut out and repoint defective joints. 2. On all joints exposed to the weather, tool and make smooth, solid, and watertight. Match existing joint profile and size, or as specified on the Drawings. B. Joint pattern: 3.4 PROTECTION 2. Match to existing of structure. A. At the completion of each working day, or when work is not in progress, cover top of all walls or masonry work with a waterproof membrane. 1. Membrane shall extend two feet down on each side of masonry and be securely anchored. 3.5 POINTING AND CLEANING A. At the completion of this portion of the Work, visually inspect the Work of this Section and point, or cut out the repointed if necessary, all holes and defective joints. B. Thoroughly clean all brick surfaces to be left exposed in the finished Work, removing all traces of mortar, grout, and foreign matter. In the event ordinary cleaning is not adequate, provide additional cleaning as so directed by Architect, and at no additional cost to the Owner. END OF SECTION

SECTION BRICK MASONRY ASSEMBLIES

SECTION BRICK MASONRY ASSEMBLIES PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following: 1. Face brick. 2. Mortar and grout. 3. Ties and anchors. 4. Miscellaneous masonry accessories. 1.2 SUBMITTALS A. Product Data: For each type

More information

SECTION MORTAR

SECTION MORTAR PART l - SCOPE SECTION 04100 - MORTAR A. This Section includes all labor, materials, equipment, and related items required for the work of mortar as shown on the Drawings and specified herein. The work

More information

DURRELL DESIGN GROUP, PLLC ROOF REPLACEMENT BARR ELEMENTARY SCHOOL JACKSON PUBLIC SCHOOL DISTRICT JACKSON, MISSISSIPPI.

DURRELL DESIGN GROUP, PLLC ROOF REPLACEMENT BARR ELEMENTARY SCHOOL JACKSON PUBLIC SCHOOL DISTRICT JACKSON, MISSISSIPPI. DURRELL DESIGN GROUP, PLLC 500-G E. WOODROW WILSON AVENUE JACKSON, MISSISSIPPI 39216 PHONE: 601.708.4788 FAX: 601.488.4717 ROOF REPLACEMENT BARR ELEMENTARY SCHOOL JACKSON PUBLIC SCHOOL DISTRICT JACKSON,

More information

1. Repairing brick masonry, including replacing damaged units as indicated on drawings. 2. Repointing mortar joints.

1. Repairing brick masonry, including replacing damaged units as indicated on drawings. 2. Repointing mortar joints. SECTION 040120 BRICK MASONRY REPAIR AND REPOINTING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION Vitrified Clay Wall Coping 2014

SECTION Vitrified Clay Wall Coping 2014 SECTION 04220 2014 PART 1 GENERAL 1.1 DESCRIPTION A. SCOPE OF WORK 1. Provide new coping as indicated on Drawings. B. RELATED SECTIONS 1. Section 02050: Selective Demolition. 2. Section 07650: Metal Flashing.

More information

SECTION UNIT MASONRY

SECTION UNIT MASONRY SECTION 04200 UNIT MASONRY PART 1 GENERAL 1.01 SUMMARY A. Furnish labor, materials, and equipment and perform functions required in the installation and maintenance of the work covered by this Section.

More information

PROGRAM COMMENT FOR DEPARTMENT OF DEFENSE REHABILITATION TREATMENT MEASURES

PROGRAM COMMENT FOR DEPARTMENT OF DEFENSE REHABILITATION TREATMENT MEASURES PROGRAM COMMENT FOR DEPARTMENT OF DEFENSE REHABILITATION TREATMENT MEASURES APPENDIX 1 SECTION 04100.01 REMOVAL OF MORTAR JOINTS AND REPOINTING PART 1 GENERAL 1.01 DESCRIPTION A. This specification provides

More information

Conditions of the Contract and Division 1 General Requirements are a part of this section.

Conditions of the Contract and Division 1 General Requirements are a part of this section. NOTES TO SPECIFIER General notes about the specifications and the reasons for them are listed here in general statements. Use this as a guide when choosing the correct selection of statements that apply

More information

1. Removal of existing deteriorated brick units 2. Installation of new brick units 3. Repointing to repair deteriorated or missing mortar

1. Removal of existing deteriorated brick units 2. Installation of new brick units 3. Repointing to repair deteriorated or missing mortar SECTION 04 01 20.91 REPLACEMENT AND/OR INSTALLATION OF BRICK MASONRY AND/OR REPOINTING PART I GENERAL 1.1 SUMMARY A. Furnish all labor, materials and accessories, equipment and services necessary for the

More information

SECTION UNIT PAVERS

SECTION UNIT PAVERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following: 1. Concrete pavers. 2. Detectable warning pavers. 3. Warning stripe pavers. 1.2 SUBMITTALS A. Product Data: For the following: 1. Pavers.

More information

Maintenance of Unit Masonry

Maintenance of Unit Masonry University of New Hampshire University of New Hampshire Scholars' Repository Division 04 Masonry Chapter 5 Technical Construction and Renovation Standards 1-25-2013 040120 - Maintenance of Unit Masonry

More information

A. Section includes historic treatment work consisting of rep ointing brick masonry as follows:

A. Section includes historic treatment work consisting of rep ointing brick masonry as follows: SECTION 040323 - HISTORJC BRlCK UNIT MASONRY REPOINTING PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Paragraph Description Page No General Materials Concrete Masonry Work Altitude Valve Vault Cover 25-4

Paragraph Description Page No General Materials Concrete Masonry Work Altitude Valve Vault Cover 25-4 City of Columbia Engineering Regulations PART 25: SPECIFICATIONS FOR ALTITUDE VALVE VAULT Table of Contents Paragraph Description Page No. 25.1 General 25-1 25.2 Materials 25-1 25.3 Concrete Masonry Work

More information

Construction Standards PAGE

Construction Standards PAGE Construction Standards PAGE 071619-1 SECTION 071619 PART 1 - GENERAL 1.1 M.S.U. ISSUES A. Below grade construction should be protected by self-adhering sheet waterproofing in accordance with SECTION 071326

More information

SECTION CAST-IN-PLACE CONCRETE

SECTION CAST-IN-PLACE CONCRETE SECTION 03300 CAST-IN-PLACE CONCRETE PART 1 GENERAL 1.01 SECTION INCLUDES A. The Contractor shall furnish all work and materials, including cement, sand and coarse aggregate, water, admixtures, curing

More information

B. Samples: Submit, for verification purposes, samples of the following:

B. Samples: Submit, for verification purposes, samples of the following: SECTION 04500 - MASONRY RESTORATION AND CLEANING PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings, photos and general provisions of Contract, including General and Supplementary Conditions and Division-1

More information

SPECIFICATION GUIDELINE

SPECIFICATION GUIDELINE SPECIFICATION GUIDELINE Environmental Stoneworks Corporate Office 6300 East Stapleton Drive South Denver, CO 80216 Phone (303) 309-3040 Fax (303) 309-3059 www.estoneworks.com Environmental Stoneworks specification

More information

SPECIFICATION GUIDELINE

SPECIFICATION GUIDELINE Environmental StoneWorks specification guideline should be used to assist design professionals in the preparation of projects. Edit and delete items that may not be applicable. Verify all referenced section

More information

SECTION GLASS UNIT MASONRY ASSEMBLIES

SECTION GLASS UNIT MASONRY ASSEMBLIES PART 1 GENERAL 1.01 SCOPE OF WORK A. The Contractor shall furnish and install all materials, labor, equipment and incidentals required to install glass unit masonry as shown on the contract drawings and

More information

Master Specifications for Microcotta November 2017

Master Specifications for Microcotta November 2017 SECTION 042130 - MICROCOTTA PART 1 - GENERAL 1.1 SUMMARY A. Provide Architectural Microcotta, cast architectural polymer resin units manufactured in accordance with the Contract Documents. 1.2 WORK INCLUDED

More information

SECTION PORTLAND CEMENT PLASTER (STUCCO) WITH ACRYLIC FINISH

SECTION PORTLAND CEMENT PLASTER (STUCCO) WITH ACRYLIC FINISH SECTION 09 24 23 - PORTLAND CEMENT PLASTER (STUCCO) WITH ACRYLIC FINISH PART I - GENERAL 1.01 SECTION INCLUDES A. Building paper B. Lath and accessories C. Plaster materials D. Acrylic finish E. Exterior

More information

SECTION SANDSTONE RESTORATION

SECTION SANDSTONE RESTORATION SECTION 04 01 40.91 - SANDSTONE RESTORATION Part 1 GENERAL 1.1 SUMMARY OF WORK A. For repairing and patching of sandstone. B. Related Sections 1. Section 01351 Special Procedures for Historic Treatment

More information

CELCORE CELLULAR INSULATING CONCRETE SPECIFICATION FOR RETROFIT PLACEMENT OVER EXISTING ROOF MEMBRANES

CELCORE CELLULAR INSULATING CONCRETE SPECIFICATION FOR RETROFIT PLACEMENT OVER EXISTING ROOF MEMBRANES PART 1: SCOPE CELCORE CELLULAR INSULATING CONCRETE SPECIFICATION FOR RETROFIT PLACEMENT OVER EXISTING ROOF MEMBRANES 1.1 An Approved Celcore Applicator shall furnish all labor, materials and supervision

More information

SECTION UNIT MASONRY ASSEMBLIES

SECTION UNIT MASONRY ASSEMBLIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Concrete masonry units. 2. Decorative masonry units. 3. Mortar and grout. 4. Steel reinforcing bars. 5. Masonry joint reinforcement. 6. Ties and anchors.

More information

TILE TILE

TILE TILE 09300 - TILE 09300-1 PART ONE: GENERAL 1.1 Description TILE 1.1.1 Work of this Section, as shown or specified, shall be provided by the Interior Contractor and shall be in accordance with the requirements

More information

POLYACRYLATE MODIFIED THINSET TERRAZZO 1

POLYACRYLATE MODIFIED THINSET TERRAZZO 1 PART 1 - GENERAL GUIDE SPECIFICATION POLYACRYLATE MODIFIED THINSET TERRAZZO - REVISED AUG 02 1.1 RELATED DOCUMENTS A. Section includes thin set Polyacrylate Modified Terrazzo flooring (and integral cove

More information

SECTION BRICK FLOORING

SECTION BRICK FLOORING SECTION 09 63 13 BRICK FLOORING SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Brick flooring

More information

BUILDING STONE PRODUCTS, INC.

BUILDING STONE PRODUCTS, INC. Specifications for Renaissance Masonry Units Developed by Arriscraft International Corporation To be used as a guide for Architectural Specifications Product A calcium silicate building unit produced for

More information

REINFORCED CONCRETE MASONRY SECTION

REINFORCED CONCRETE MASONRY SECTION SECTION 04 22 02 - REINFORCED CONCRETE MASONRY PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 096623 - RESINOUS MATRIX TERRAZZO FLOORING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

BENTONITE WATERPROOFING

BENTONITE WATERPROOFING SECTION 07 17 00 BENTONITE WATERPROOFING PART 1 - GENERAL 1.1 SUMMARY A. Furnish and install bentonite waterproofing system where shown on the drawings, as specified herein, and as needed for a complete

More information

SUNY GENESEO RED JACKET DINING HALL RENOVATION THIN BRICK MASONRY

SUNY GENESEO RED JACKET DINING HALL RENOVATION THIN BRICK MASONRY SUNY GENESEO 042113.13-1 SECTION 042113.13 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

CSI SECTION MAINTENANCE OF CONCRETE Repair & Resurfacing with Rapid Hardening, High Strength, Low-Shrink, Non-Metallic Cementitious Materials

CSI SECTION MAINTENANCE OF CONCRETE Repair & Resurfacing with Rapid Hardening, High Strength, Low-Shrink, Non-Metallic Cementitious Materials CSI SECTION 03 01 00 MAINTENANCE OF CONCRETE Repair & Resurfacing with Rapid Hardening, High Strength, Low-Shrink, Non-Metallic Cementitious Materials EDITOR NOTE: The following guideline specification

More information

PROJECT NAME: PROJECT ADDRESS: Farmers Market Structural Repairs 4-6 Gordon Street Guelph, Ontario DATE: November, 2010 I N D E X Page(s) Index... 1 to 1 Introduction... 1 to 1 DIVISION 04 - MASONRY Section

More information

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Multi-Institutional Academic Health Science & Research Center Evansville, IN SECTION 07 1616 - CRYSTALLINE WATERPROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Kolorines Glass Mosaic Tiles Project Specification

Kolorines Glass Mosaic Tiles Project Specification Kolorines Glass Mosaic Tiles Project Specification SUGGESTED SPECIFICATION Glass Mosaic Tile Installation for Swimming Pools NOTES TO SPECIFIER: 1. Specify PremiumPlus Thin-Set mixed with CustomFlex Additive

More information

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION STUC-O-FLEX - ELASTOMERIC ACRYLIC FINISH APPLICATION TO PORTLAND CEMENT PLASTER / CONCRETE RENDER MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION 09220-09 24 00 PART 1-GENERAL SCOPE: Manufacturer's

More information

MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION

MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION STUC-O-FLEX - ELASTOMERIC ACRYLIC FINISH APPLICATION TO PORTLAND CEMENT PLASTER / CONCRETE RENDER MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION 09220-09 24 00 PART 1-GENERAL SCOPE: Manufacturer's

More information

SECTION 44 SHOTCRETE, CAST CONCRETE CHANNEL LINING, AND GROUTED COBBLE TABLE OF CONTENTS

SECTION 44 SHOTCRETE, CAST CONCRETE CHANNEL LINING, AND GROUTED COBBLE TABLE OF CONTENTS SECTION 44 SHOTCRETE, CAST CONCRETE CHANNEL LINING, AND GROUTED COBBLE TABLE OF CONTENTS Section Page 44-1 SHOTCRETE... 44.1 44-1.01 Description... 44.1 44-1.02 Materials... 44.1 44-1.03 Proportions...

More information

MANUFACTURER S SPECIFICATIONS Section ST. ASTIER LIME PLASTER (NHL) MASONRY [BLOCKS] [BRICKS] [STONE]

MANUFACTURER S SPECIFICATIONS Section ST. ASTIER LIME PLASTER (NHL) MASONRY [BLOCKS] [BRICKS] [STONE] MANUFACTURER S SPECIFICATIONS Section 09225 ST. ASTIER LIME PLASTER (NHL) MASONRY [BLOCKS] [BRICKS] [STONE] ST. ASTIER NATURAL HYDRAULIC LIME PLASTER PART 1 GENERAL 1.1 Summary A. This Section includes

More information

SECTION SITE CONCRETE

SECTION SITE CONCRETE SECTION 321313 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting

More information

Spec Master 5/7/ For each product requiring color and texture selection, provide full size samples.

Spec Master 5/7/ For each product requiring color and texture selection, provide full size samples. SECTION 04812 (042012) MECHANICALLY ATTACHED BRICK PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION 44 SHOTCRETE, CAST CONCRETE CHANNEL LINING, AND GROUTED COBBLE TABLE OF CONTENTS

SECTION 44 SHOTCRETE, CAST CONCRETE CHANNEL LINING, AND GROUTED COBBLE TABLE OF CONTENTS SECTION 44 SHOTCRETE, CAST CONCRETE CHANNEL LINING, AND GROUTED COBBLE TABLE OF CONTENTS Section Page 44-1 SHOTCRETE 44-1 44-1.01 Description 44-1 44-1.02 Materials 44-1 44-1.03 Proportions 44-1 44-1.04

More information

Stanford University Facilities Design Guidelines SECTION ASPHALT UNIT PAVING. A. ASTM C-33 Standard Specification for Concrete Aggregates.

Stanford University Facilities Design Guidelines SECTION ASPHALT UNIT PAVING. A. ASTM C-33 Standard Specification for Concrete Aggregates. SECTION 32 14 23 ASPHALT UNIT PAVING PART 1 GENERAL 1.1 DESCRIPTION Work Included: All labor, materials, appliances, tools, equipment, facilities, transportation, and services for and incidental to performing

More information

By CTS Cement Manufacturing Corp.

By CTS Cement Manufacturing Corp. CSI SECTION 03 60 00 GROUTING 03 62 00 NON-SHRINK GROUTING 03 62 13 NON-METALLIC NON-SHRINK GROUTING High Flow, Non-Metallic, Multi-Purpose, Cementitious, Non-Shrink Grout EDITOR NOTE: The following guideline

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MORTAR AND MASONRY GROUT

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MORTAR AND MASONRY GROUT SECTION 04110 MORTAR AND MASONRY GROUT PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. In the absence of other information, the methods and recommendations of the National Concrete Masonry Association

More information

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT SPECIFICATION EO-1007 REVISION 13 DECEMBER 2013 EFFECTIVE DATE DECEMBER 16,

More information

SECTION QUARRY TILE

SECTION QUARRY TILE SECTION 09 30 16 QUARRY TILE PART 1 GENERAL 1.1 SECTION REQUIREMENTS A. Provide all labor, materials and equipment required for the installation of quarry tile flooring as shown on drawings and schedules

More information

SECTION EPOXY TERRAZZO

SECTION EPOXY TERRAZZO SECTION 09402 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to

More information

MANUFACTURER'S SPECIFICATIONS Section ST. ASTIER LIME PLASTER (NHL) PLASTER ON CONCRETE

MANUFACTURER'S SPECIFICATIONS Section ST. ASTIER LIME PLASTER (NHL) PLASTER ON CONCRETE MANUFACTURER'S SPECIFICATIONS Section 09225 ST. ASTIER LIME PLASTER (NHL) PLASTER ON CONCRETE ST. ASTIER NATURAL HYDRAULIC LIME PLASTER PART 1 GENERAL 1.1 Summary A. This Section includes St. Astier Natural

More information

SECTION DRY-PLACED GRANITE

SECTION DRY-PLACED GRANITE SECTION 04 41 11 DRY-PLACED GRANITE This guide specification utilizes recommendations and formats contained in references of the Construction Specifications Institute (CSI), including the CSI Practice

More information

SECTION BRICKWORK PART I GENERAL

SECTION BRICKWORK PART I GENERAL SECTION 04210 BRICKWORK PART I GENERAL 101 Scope General: supply and build the brickwork shown on the drawings or needed to complete the brickwork, including but not limited to the following: Provide all

More information

MANUFACTURER S SPECIFICATION

MANUFACTURER S SPECIFICATION MANUFACTURER S SPECIFICATION Eldorado Stone Corporation PO Box 489 Carnation, WA 98014 Tel: (800) 925-1491 Fax: (425) 333-4755 e-mail: general@eldoradostone.com website: www.eldoradostone.com SECTION 04730

More information

TEX COTE 600 TEXTURED COATING MASONRY PROTECTIVE COATING

TEX COTE 600 TEXTURED COATING MASONRY PROTECTIVE COATING SECTION 09960 - TEXTURED COATINGS Coating System Submittals Guide Specification TEX COTE 600 TEXTURED COATING MASONRY PROTECTIVE COATING (SPLIT FACE OR SAND FINISH BLOCK) 1. TEX COTE 600, Textured Coating

More information

BRICKWORK 3.5 BRICKWORK 1 GENERAL

BRICKWORK 3.5 BRICKWORK 1 GENERAL BRICKWORK 1 GENERAL 1.1 INSPECTION Notice Give sufficient notice so that inspection may be made of the following: - Set out of brickwork to lintels, arches and other architectural features. - Damp-proof

More information

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 STUC-O-FLEX PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 PART 1 - GENERAL 1.01 DESCRIPTION Provide all labor, materials and equipment necessary

More information

TECHNICAL ADVISORY NOTE Basic Guide for Installing Molded Brick

TECHNICAL ADVISORY NOTE Basic Guide for Installing Molded Brick 700 Tuscarawas Street West Canton, OH 44701 (330) 456-0031 15718 Clear Spring Road Williamsport, MD 21795 (301) 223-7700 TECHNICAL ADVISORY NOTE Basic Guide for Installing Molded Brick Molded brick have

More information

This Section includes surface preparation and field application of anti-graffiti coating systems for the following vertical and horizontal surfaces:

This Section includes surface preparation and field application of anti-graffiti coating systems for the following vertical and horizontal surfaces: 0 0 0 0 0 0 SECTION 0 ANTI- GRAFFITI COATINGS PART - GENERAL RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division Specification

More information

SECTION CONCRETE TILE ROOFING. A. American Society for Testing and Materials (ASTM):

SECTION CONCRETE TILE ROOFING. A. American Society for Testing and Materials (ASTM): SECTION 07324 CONCRETE TILE ROOFING PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 06100 - Carpentry. 2. 07600 - Flashing and Sheet Metal. 1.02 REFERENCES A. American Society for Testing and Materials

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION SECTION 07320 TWO-PIECE TAPERED MISSION CLAY ROOFING TILE PART 1 GENERAL 1.01 SECTION INCLUDES A. Formed clay roofing tiles, complete with components and other required accessories

More information

Thin Architectural Splitface Block Veneer Specification Guide

Thin Architectural Splitface Block Veneer Specification Guide Thin Architectural Splitface Veneer System with AccuTab Technology R Thin Architectural Splitface Block Veneer Specification Guide Section 04711: Manufactured Concrete Veneer Use this specification guide

More information

1. Selective Demolition Section Adhered PVC Roofing System Section Sealants and Caulking Section 07920

1. Selective Demolition Section Adhered PVC Roofing System Section Sealants and Caulking Section 07920 SECTION 07620 - FLASHING AND SHEET METAL PART 1 - GENERAL 1.01 DESCRIPTION A. Work included: Provide all flashing and sheet metal not specifically described in other Sections of these Specifications but

More information

MANUFACTURER S SPECIFICATIONS Section LIMESTONE PLASTER

MANUFACTURER S SPECIFICATIONS Section LIMESTONE PLASTER MANUFACTURER S SPECIFICATIONS Section 09220 LIMESTONE PLASTER LE DÉCOR LIMESTONE PART 1 GENERAL 1.1 General A. This section describes the requirements for furnishing and installing Limestone Plaster. 1.2

More information

SECTION GLADDING, McBEAN ARCHITECTURAL TERRA COTTA May 31, Provide new terra cotta as indicated on Drawings.

SECTION GLADDING, McBEAN ARCHITECTURAL TERRA COTTA May 31, Provide new terra cotta as indicated on Drawings. SECTION 04210 GLADDING, McBEAN ARCHITECTURAL TERRA COTTA May 31, 2016 PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Provide new terra cotta as indicated on Drawings. 2. Detail, furnish, and install

More information

MASONRY MORTARING

MASONRY MORTARING 2025 Centre Pointe Blvd. Suite 260 Mendota Heights, MN 55120 Phone: (888) 773-2649 (651) 994-7120 Fax: (888) 329-7732 E-mail: info@specmix.com www.specmix.com This MANU-SPEC utilizes the Construction Specifications

More information

EPOXY TERRAZZO 1 REV. 8/02

EPOXY TERRAZZO 1 REV. 8/02 PART 1 - GENERAL GUIDE SPECIFICATIONS section 9400 EPOXY THINSET TERRAZZO (Without A Crack Suppression Membrane) REVISED MAY 2003 1.1 RELATED DOCUMENTS A. Section includes thin-set epoxy terrazzo flooring

More information

SECTION SPLIT FACE CONCRETE MASONRY UNITS

SECTION SPLIT FACE CONCRETE MASONRY UNITS SECTION 04223 SPLIT FACE CONCRETE MASONRY UNITS ***** E. Dillon & Company manufactures the following high quality, custom produced, architectural concrete masonry units (CMU) using superior colored aggregates

More information

CONCRETE TILE PAVERS

CONCRETE TILE PAVERS Section 32 14 13 CONCRETE TILE PAVERS (1995 MasterFormat Section 02780) Note: This guide specification for the U.S. is for the installation of concrete tile paving units whose thickness are less than the

More information

ITEM 431 PNEUMATICALLY PLACED CONCRETE. All material shall conform to the pertinent requirements of the following items:

ITEM 431 PNEUMATICALLY PLACED CONCRETE. All material shall conform to the pertinent requirements of the following items: ITEM 431 PNEUMATICALLY PLACED CONCRETE 431.1. Description. This Item shall govern for furnishing and placing of "Pneumatically Placed Concrete" for encasement of designated structural steel members, the

More information

GUIDE SPEC SECTION Injection Grout (IG10)

GUIDE SPEC SECTION Injection Grout (IG10) Part 1 GENERAL MASONRY UNIT RESTORATION 1.1 SUMMARY OF WORK A. For repairing, patching, injecting cracks and re-attaching stone fragments to original substrate. B. Related Sections 1. Section 01351 Special

More information

Maintenance of Brick Masonry

Maintenance of Brick Masonry TECHNICAL NOTES on Brick Construction 46 1850 Centennial Park Drive, Reston, Virginia 20191 www.gobrick.com 703-620-0010 Maintenance of Brick Masonry Abstract: Even though one of the major advantages of

More information

PART 1 GENERAL MANUFACTURED STONE MASONRY

PART 1 GENERAL MANUFACTURED STONE MASONRY SECTION 04 73 00 (04730) PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Simulated Stone B. Products installed, but not furnished, under this Section include the following: 1. Steel Lintel and Shelf

More information

DIVISION 4 MASONRY DIVISION 4 - MASONRY

DIVISION 4 MASONRY DIVISION 4 - MASONRY DIVISION 4 MASONRY DIVISION 4 - MASONRY 85 SECTION 04000 - MASONRY 04000 - MASONRY PART 1 - GENERAL 1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

1/16 Single Broadcast Polymer Flooring System

1/16 Single Broadcast Polymer Flooring System specification 1/16 Single Broadcast Polymer Flooring System Part 1 - GENERAL General Provisions A. Work to be covered by this section, under written specification or by drawing, shall comply with all provisions

More information

A. Provide brick masonry where shown on the Drawings, as specified herein, and as needed for complete and proper installation.

A. Provide brick masonry where shown on the Drawings, as specified herein, and as needed for complete and proper installation. SECTION 04210 PART ONE GENERAL 1.1 SECTION INCLUDES A. Brick Masonry. 1.2 DESCRIPTION A. Provide brick masonry where shown on the Drawings, as specified herein, and as needed for complete and proper installation.

More information

INSULATED CONCRETE MASONRY UNITS Section 04220

INSULATED CONCRETE MASONRY UNITS Section 04220 INSULATED CONCRETE MASONRY UNITS Section 04220 PART 1 GENERAL 1.01 Summary A. Section Includes 1. Insulated masonry wall units (CMU's) 2. Decorative insulated masonry wall units 1.02 SUBMITTALS A. Samples:

More information

A. Drawings and general provisions of the contract, including General and Supplementary Conditions, apply to this section.

A. Drawings and general provisions of the contract, including General and Supplementary Conditions, apply to this section. Product Specification for: Rapid Set DOT Repair Mix SECTION 03 01 30 MAINTENANCE OF CAST-IN-PLACE CONCRETE SECTION 03 01 40 MAINTENANCE OF PRECAST CONCRETE SECTION 03 01 50 MAINTENANCE OF CAST DECKS AND

More information

SECTION BRICKWORK

SECTION BRICKWORK SECTION 04210 BRICKWORK THERE ARE NOTES AND CLAUSES IN THE SUSTAINABILITY GUIDE ON THIS TRADE. THIS TRADE SECTION DEPENDS ON COORDINATION BETWEEN THIS SPECIFICATION AND THE FINISHES SCHEDULE AS WELL AS

More information

(Specification writer shall choose the most appropriate section that applies to a given scope of work) SECTION Painting and Coating

(Specification writer shall choose the most appropriate section that applies to a given scope of work) SECTION Painting and Coating Guide Specification Miracote Mirastain Architectural Staining System (Specification writer shall choose the most appropriate section that applies to a given scope of work) PART 1 - GENERAL 1.1 SUMMARY

More information

DIVISION 04 MASONRY. Section Title Number MASONRY Maintenance of Masonry Masonry Mortaring Masonry Accessories

DIVISION 04 MASONRY. Section Title Number MASONRY Maintenance of Masonry Masonry Mortaring Masonry Accessories 04 00 00 MASONRY 04 01 00 Maintenance of Masonry 04 01 20 Maintenance of Masonry 04 05 13 Masonry Mortaring 04 05 23 Masonry Accessories 04 20 00 UNIT MASONRY 04 21 00 Clay Unit and Brick Veneer 04 22

More information

MARQUIS Tualatin FIBER-CEMENT SIDING June 15, rev

MARQUIS Tualatin FIBER-CEMENT SIDING June 15, rev PART 1 - GENERAL 1.1 SUMMARY A. This Section includes: 1. Reinforced fiber-cement shingle panel siding, 2. Reinforced fiber-cement lap siding. B. Related Sections: 1. Division 1 Section "Quality Requirements"

More information

SECTION CONCRETE TILE ROOFING Carpentry Flashing and Sheet Metal. A. American Society for Testing and Materials (ASTM):

SECTION CONCRETE TILE ROOFING Carpentry Flashing and Sheet Metal. A. American Society for Testing and Materials (ASTM): SECTION 07324 CONCRETE TILE ROOFING PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 06100 - Carpentry. 2. 07600 - Flashing and Sheet Metal. 1.02 REFERENCES A. American Society for Testing and Materials

More information

SECTION ARCHITECTURAL CONCRETE UNIT MASONRY

SECTION ARCHITECTURAL CONCRETE UNIT MASONRY SECTION 04 2223 PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Split-face concrete unit masonry, burnished concrete unit masonry, and polished concrete unit masonry. 2. Split-face concrete unit masonry.

More information

REFLECTIVE FACE CONCRETE MASONRY UNITS

REFLECTIVE FACE CONCRETE MASONRY UNITS SECTION 04221 REFLECTIVE FACE CONCRETE MASONRY UNITS ***** E. Dillon & Company manufactures the following high quality, custom produced, architectural concrete masonry units (CMU) using superior colored

More information

University of New Hampshire Scholars' Repository

University of New Hampshire Scholars' Repository University of New Hampshire University of New Hampshire Scholars' Repository Division 07 Thermal and Moisture Protection Chapter 5 Technical Construction and Renovation Standards 1-25-2013 075423 - TPO

More information

SECTION CONCRETE TILE ROOFING Carpentry Flashing and Sheet Metal. A. American Society for Testing and Materials (ASTM):

SECTION CONCRETE TILE ROOFING Carpentry Flashing and Sheet Metal. A. American Society for Testing and Materials (ASTM): SECTION 07324 CONCRETE TILE ROOFING PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 06100 - Carpentry. 2. 07600 - Flashing and Sheet Metal. 1.02 REFERENCES A. American Society for Testing and Materials

More information

B. All work of the section shall comply with the conditions of the contract, the drawings and any special conditions forming a part of the contract.

B. All work of the section shall comply with the conditions of the contract, the drawings and any special conditions forming a part of the contract. SPECIFICATIONS PART ONE - GENERAL ------------------------------------------------------------------------ 1.01 General Description A. The Cementitious capillary waterproofing materials specified herein

More information

SECTION MAINTENANCE OF STONE ASSEMBLIES

SECTION MAINTENANCE OF STONE ASSEMBLIES SECTION 04 01 40 - MAINTENANCE OF STONE ASSEMBLIES PART 1 GENERAL 1.1 SUMMARY OF WORK A. Submit the following items in time to prevent delay of the work and to allow adequate time for review, do not order

More information

CONSULT COLDSPRING FOR ASSISTANCE IN EDITING THIS SPECIFICATION GUIDE FOR SPECIFIC APPLICATIONS.

CONSULT COLDSPRING FOR ASSISTANCE IN EDITING THIS SPECIFICATION GUIDE FOR SPECIFIC APPLICATIONS. SECTION NUMBERS AND TITLES IN THIS SPECIFICATION UTILIZE MASTERFORMAT 2004. THIS SPECIFICATION GUIDE IS WRITTEN ACCORDING TO THE CONSTRUCTION SPECIFICATIONS INSTITUTE (CSI) THREE-PART SECTION FORMAT (1998)

More information

GUIDE SPECIFICATION SECTION CRYSTALLINE WATERPROOFING

GUIDE SPECIFICATION SECTION CRYSTALLINE WATERPROOFING GUIDE SPECIFICATION SECTION 071616 PART 1 - GENERAL CRYSTALLINE WATERPROOFING 1.1 SECTION INCLUDES A. Cementitious Crystalline Waterproofing on concrete structures and surfaces as shown on drawings and

More information

SECTION CONCRETE PAVING SLABS SET IN MORTAR

SECTION CONCRETE PAVING SLABS SET IN MORTAR SECTION 32 14 13.16 CONCRETE PAVING SLABS SET IN MORTAR (1995 MasterFormat Section 02784) Note: This guide specification for the U.S. is for paving slabs mortared to a concrete base and grouted joints

More information

A. Section includes cast-in-place concrete, including reinforcement, concrete materials, mixture design, placement procedures, and finishes.

A. Section includes cast-in-place concrete, including reinforcement, concrete materials, mixture design, placement procedures, and finishes. SECTION 033053 - CONCRETE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SPECIAL SPECIFICATION 2043 Brick Veneer on MSE Wall

SPECIAL SPECIFICATION 2043 Brick Veneer on MSE Wall 2004 Specifications CSJ 0196-02-120 SPECIAL SPECIFICATION 2043 Brick Veneer on MSE Wall 1. Description. This Item shall govern for the furnishing of the materials and construction of brick veneers on abutment

More information

SECTION MANUFACTURED MASONRY VENEER

SECTION MANUFACTURED MASONRY VENEER TM Dutch Quality Stone 18012 Dover Road Mt. Eaton, OH 44659 Tel: (330) 359-7866 Fax: (330) 359-5990 e-mail: info@dutchqualitystone.com website: www.dutchqualitystone.com SECTION 04 73 00 MANUFACTURED MASONRY

More information

SECTION Specification for Building Limes Specification For Building Sands from Natural Sources Methods of Tests for Paints.

SECTION Specification for Building Limes Specification For Building Sands from Natural Sources Methods of Tests for Paints. SECTION 09200 PART 1 - GENERAL 1.01 DESCRIPTION A. Extent of Work: The extent of lath and plaster work is shown on the drawings and in schedules and includes interior and exterior plaster work, and fibreglass

More information

Florock Seamless Flooring Systems

Florock Seamless Flooring Systems Architectural Specification FloroCrete RT Rake/Trowel Urethane Mortar 3/16-1/4 (4.5-6.0 mm) Floor Resurfacing System Part 1: General 1.01 System Description A. System I Skid-Resistant Finish Resurfacing

More information

SIDER-BASE CONCENTRATE AAC/ MONOSIDERAL AAC THE ULTIMATE OLD-WORLD AERATED CONCRETE-AAC DECORATIVE STUCCO SYSTEM

SIDER-BASE CONCENTRATE AAC/ MONOSIDERAL AAC THE ULTIMATE OLD-WORLD AERATED CONCRETE-AAC DECORATIVE STUCCO SYSTEM SIDER-CRETE, INC. 153 Regur Road Hawkinsville, GA 31036 USA Ph: 478.892.9800 www.sider-crete.com SIDER-BASE CONCENTRATE AAC/ MONOSIDERAL AAC THE ULTIMATE OLD-WORLD AERATED CONCRETE-AAC DECORATIVE STUCCO

More information

SECTION NATURAL STONE VENEER

SECTION NATURAL STONE VENEER CSI 3-PART SPEC Eldorado Stone 1370 Grand Ave., Bldg. B San Marcos, CA 92069 tel: (800) 925-1491 fax: (760) 736-8890 e-mail: contactus@eldoradonatural.com website: www.eldoradonatural.com SECTION 04 43

More information