Roof e Flat r xhaust trap oof ventilators 4 models for FLAT ROOF
|
|
- Marybeth Kennedy
- 6 years ago
- Views:
Transcription
1 models for FLAT ROOF Model VMAX-02-2 Deflector : Base : degree cant. Height : 23 / in. NFA : 9 in. 2 Ventilation Area : 00 to 0 ft. 2 Colours : Black, brown, grey and white CSA : Approved Model VMAX-02-2-MB Deflector : Base : insulated interior Height : / in. NFA : 9 in. 2 Ventilation Area : 00 to 0 ft. 2 Colours : Black, brown, grey and white CSA : Approved Model VMAX-0-2 Deflectors : Base : degree cant. Height : /2 in. NFA : in. 2 Ventilation Area : to 00 ft. 2 NB : For net air space between insulation & underside of roof deck of in. and more Colours : Black, brown, grey and white CSA : Approved Model VMAX-20-2-MB Deflectors : Base ; insulated interior NFA : 2 in. 2 Height : /2 in. Ventilation Area : to 0 ft. 2 NB : For net air space between insulation & underside of roof deck of in. and more Colours: Black, brown, grey and white CSA : Approved Features Steel : Structural galvanized steel ZF7 Gauge : & 2 Storm proof : Unique precision engineered deflector system Rodent proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection. Warranty : Limited Lifetime Warranty on all manufacturing defects, years on paint & corrosion.
2 Flat roof ventilators MODEL VMAX-02-2 Description Unlike the turbine, the Maximum Ventilators are CSA approved and do not require to rotate to prevent water or snow infiltrations. Its unique storm proof system prevents infiltrations while at the same time capturing the wind flow from all directions and at wind velocities as low as km./hr. ( mi./hr.). With this combination of technology, wind and pressure differentials, a chimney or, vacuum effect results in drawing the stale air and moisture out, thus preventing moisture & heat build-up within the attic space. This model has been designed to be installed onto a wooden curb. The thickness of the wooden curb in conjunction with the thickness of the roofing membrane will determine the size of the ventilator required. The interior dimension of the wood curb should equal to the opening in the deck to allow for unobstructed air flow. The suggested roof area for one () ventilator model VMAX-02-2 has been calculated based on a 0 in. x 0 in. opening or (hole) of curb and roof deck. Specifications & Features A limited selection of special colours are available at a small premium. Please refer to chart on the following page for larger dimensions that are available by special order. Model : VMAX-02-2 Deflector : Net Free Evacuation : 9 in. 2 Suggested Ventilation Area : 00 to 0 ft. 2 Tested Extraction Rate: 3 CFM Base Flashing : degree cant flashing Storm Proof : Unique precision engineered deflector system Solid : Built of structural galvanized steel Standard Gauge : & 2 Rodent Proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, years on paint & corrosion Available Colours : Black, brown, grey, and white Compliances : CSA, CAN-3-A930M82, ASTM Pierre Bonne, Montreal HE 7J Tel.: Fax : Watts: (Canada)
3 DIMENSIONS AND SPECIAL CHARACTERISTICS Please refer to the section on recommendations for flat roofs for additional information. A CODE# DIMENSIONS A B C D THE NET VENTILATION EVACUATION FOR MODEL 02-2 NUMBER OF DEFLECTOR STEEL GAUGE USED IN. 2 2 METRIC (mm) M IN. 2 C M IN. 2 B M IN M. 2 D IN M IN M IN M. 2 The models #02- to #02- are available by special orders only. Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job Pierre Bonne, Montreal HE 7J Tel.: Fax : Watts: (Canada)
4 Roof exhaust trap Flat roof ventilators MODEL VMAX-0-2 Description VENTILATION CHART FOR MODEL VMAX-0-2 Net Ventilation air space between underside of roof deck & insulation in. to in. 7 in. to 2 in. 3 in. to in. Roof Area that one Ventilation 0 (2 x 2 ) can ventilate 0 is not recommended Use Model ft ft. 2 Unlike the turbine, the Maximum Ventilators are CSA approved and do not require to rotate to prevent water or snow infiltrations. Its unique storm proof system prevents infiltrations while at the same time capturing the wind flow from all directions and at wind velocities as low as km./hr. ( mi./hr.). With this combination of technology, wind and pressure differentials, a chimney or, vacuum effect results in drawing the stale air and moisture out, thus preventing moisture & heat build-up within the attic space. This model has been designed to be installed onto a wooden curb. The thickness of the wooden curb in conjunction with the thickness of the roofing membrane will determine the size of the ventilator required. The interior dimension of the wood curb should equal to the opening in the deck to allow for unobstructed air flow. The suggested roof area for one () ventilator model VMAX-0-2 has been calculated based on a 0 in. x 0 in. opening or (hole) of curb and roof deck. 2 in. and more ft. 2 Specifications & Features A limited selection of special colours are available at a small premium. Please refer to chart above for net ventilation area capacity and the chart on the following page for larger dimensions that are available by special order. Model : VMAX-0-2 Deflectors : Net Free Evacuation : in 2. Tested Extraction Rate : 8 CFM Suggested Ventilation Area : to 00 ft 2. (Refer to chart) Base Flashing : degree cant flashing Storm Proof : Unique precision engineered deflector system Solid : Built of structural galvanized steel Standard Gauge : & 2 Rodent Proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, years on paint & corrosion Available Colours : Black, brown, grey, and white Compliances : CSA, CAN-3-A930M82, ASTM Pierre Bonne, Montreal HE 7J Tel.: Fax : Watts: (Canada)
5 DIMENSIONS AND SPECIAL CHARACTERISTICS Please refer to the section on recommendations for flat roofs for additional information. CODE# DIMENSIONS A B C D EVACUATION NUMBER OF DEFLECTORS STEEL GAUGE USED B IN. 2 &2 METRIC (mm) M IN. 2 & M. 2 C IN M IN M. 2 A D IN M. 2 8 IN M IN M. 2 The models #0- to #0- are available by special orders only. Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job Pierre Bonne, Montreal HE 7J Tel.: Fax : Watts: (Canada)
6 Roof exhaust trap Flat roof ventilators MODEL VMAX-02-2-MB Description Unlike the turbine, the Maximum Ventilators are CSA approved and do not require to rotate to prevent water or snow infiltrations. Its unique storm proof system prevents infiltrations while at the same time capturing the wind flow from all directions and at wind velocities as low as km./hr. ( mi./hr.). With this combination of technology, wind and pressure differentials, a chimney or, vacuum effect results in drawing the stale air and moisture out, thus preventing moisture & heat build-up within the attic space. All in one, no need of a wood curb, this model has been designed to allow you to install the roofing membrane onto the base flashing the same way you would a wood curb. We have made an allowance for the membrane so that the neck of the ventilator will go over both the flashing and the membrane. Specifications & Features A limited selection of special colours are available at a small premium. Please refer to chart on the following page for larger dimensions that are available by special order. The opening of the base flashing should equal to the opening in the deck to allow for unobstructed air flow. Model : VMAX-02-2-MB Deflector : Net Free Evacuation : 9 in 2. Tested Extraction Rate : 3 CFM Suggested Ventilation Area : 00 to 0 ft 2. Base Flashing : Flat base, insulated interior flashing Storm Proof : Unique precision engineered deflector system Solid : Built of structural galvanized steel Standard Gauge : & 2 Rodent Proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, years on paint & corrosion Available Colours : Black, brown, grey and white Compliances : CSA, CAN-3-A930M82, ASTM Pierre Bonne, Montreal HE 7J Tel.: Fax : Watts: (Canada)
7 DIMENSIONS AND SPECIAL CHARACTERISTICS Please refer to the section on recommendations for flat roofs for additional information. A CODE# DIMENSIONS A B C D EVACUATION NUMBER OF DEFLECTOR STEEL GAUGE USED 02-2-MB IN. 2 2 METRIC (mm) M MB.0 7. IN. 2 C M MB IN. 2 B M MB IN M. 2 D MB IN M MB IN M MB IN M. 2 The models #02--MB to #02--MB are available by special orders only. Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job Pierre Bonne, Montreal HE 7J Tel.: Fax : Watts: (Canada)
8 Roof exhaust trap Flat roof ventilators MODEL VMAX-20-2-MB Description VENTILATION CHART FOR MODEL VMAX-20-2-MB Net Ventilation Area between roof deck & insulation Roof Area that one Ventilation 20-2-MB (2 x 2 ) can ventilate Unlike the turbine, the Maximum Ventilators are CSA approved and do not require to rotate to prevent water or snow infiltrations. Its unique storm proof system prevents infiltrations while at the same time capturing the wind flow from all directions and at wind velocities as low as km./hr. ( mi./hr.). With this combination of technology, wind and pressure differentials, a chimney or, vacuum effect results in drawing the stale air and moisture out, thus preventing moisture & heat build-up within the attic space. All in one, no need of a wood curb, this model has been designed to allow you to install the roofing membrane onto our base flashing the same way you would a wood curb. An allowance has been made for the membrane so that the neck of the ventilator will overlap both the flashing and the membrane. in. to in MB is not recommended Use Model 02-MB 7 in. to 2 in. to 20 ft. 2 3 in. to in. 2 in. and more 2 to 30 ft. 2 3 to 0 ft. 2 Specifications & Features A limited selection of special colours are available at a small premium. Please refer to chart above for net ventilation area capacity and the chart on the following page for larger dimensions that are available by special order. The opening of the base flashing should equal to the opening in the deck to allow for unobstructed air flow. Model : VMAX-20-2-MB Deflectors : Net Free Evacuation : 2 in 2. Tested Extraction Rate : 3 CFM Suggested Ventilation Area : to 0 ft 2. (Refer to chart above) Base Flashing : Flat base with insulated interior Storm Proof : Unique precision engineered deflector system Solid : Built of structural galvanized steel Standard Gauge : & 2 Rodent Proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, years on paint & corrosion Available Colours : Black, brown, grey, and white Compliances : CSA, CAN-3-A930M82, ASTM Pierre Bonne, Montreal HE 7J Tel.: Fax : Watts: (Canada)
9 DIMENSIONS AND SPECIAL CHARACTERISTICS Please refer to the section on recommendations for flat roofs for additional information. B CODE# DIMENSIONS A B C D EVACUATION NUMBER OF DEFLECTORS STEEL GAUGE USED 20-2-MB IN 2 &2 METRIC (mm) M. 2 &2 20--MB IN. 2 C 20--MB M IN M MB IN M. 2 A MB IN. 2 D M MB IN M MB IN M. 2 7 The models #20--MB to #20--MB are available by special orders only. Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job Pierre Bonne, Montreal HE 7J Tel.: Fax : Watts: (Canada)
AIR INTAKE VENTS. Special air intake Models for
Special air intake Models for AIR INTAKE VENTS Model VMAX-AT1-1213-DF Slopes : 4/12 to 15/12 Model VMAX-AT1-895-DF Slopes : 4/12 to 15/12 : air intake vent with storm proof baffle & shield that can be
More information1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500
07721 ROOF ASSEMBLY SUPPORTS FOR ROOFTOP EQUIPMENT ****************************************** SPECIFIER: All roof-related items above or outside the structural roof deck, including such work as blocking,
More informationSECTION TURBINE VENTILATORS
SECTION 07 72 00 TURBINE VENTILATORS **This is a CSI Three-Part Specification using CSI MasterFormat 2004-2010 Section Numbers and Titles. This specification must be edited to suit your particular project.
More informationCS-100 Guide Specifications
MANUFACTURER CUSTOM-BILT METALS 1333 Corporate Drive, Suite 103 Irving, Texas 75038-2520 (800) 826-7813 or info@custombiltmetals.com www.custombiltmetals.com CS-100 Guide Specifications This Guide Specification
More informationSteel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner
The Kelly Klosure pre-framed modular panel has 4 components that are factory finished to create an easy and versatile bolt-together system in the field. Steel Panel Frame Exterior Steel Sheeting Optional
More informationSTAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
More informationCANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE
CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE This specification is intended to describe the general requirements applicable to a proper structural cantilever rack design. In addition, it is
More informationSPECIFICATIONS SECTION UL LISTED HEAT AND SMOKE VENTS
SPECIFICATIONS SECTION 07 72 00 PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Prefabricated UL Listed heat and smoke vents, with Skypro UL 972 Impact resistant Skywave Arc domed lids, curbs, hardware
More informationSECTION ROOF ACCESSORIES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 72 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable
More informationLOUVER PRODUCTS. Architectural Blade Louvers Drainable Blade Louvers Wind-Driven Rain Louvers Sightproof Louvers Acoustical Louvers Thinline Louvers
LOUVER PRODUCTS Archives of Ontario Building, York University, Toronto, Ontario Architectural Blade Louvers Drainable Blade Louvers Wind-Driven Rain Louvers Sightproof Louvers Acoustical Louvers Thinline
More informationDICTATOR Lift Shaft System
DICTATOR Lift Shaft System The Modular Lift Shaft System, also for Retrofitting Certified According to EN 1090 A lift is becoming more and more important for daily life, not only in newly constructed buildings
More informationSTEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN
STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN STEEL STUD AND TRACK FOR DRYWALL PARTITIONS TAKE ADVANTAGE OF THE SAVINGS IN TIME
More informationSECTION ROOF SPECIALTIES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable
More informationB U I L T F O R L I F E
B U I L T F O R L I F E Maple Leaf Homes Built for life Every Maple Leaf Home is manufactured with high quality materials by experienced craftsmen. You can take comfort in knowing that your investment
More informationSeries - 1
SECTION 08360 SECTIONAL OVERHEAD DOORS 591 SERIES THERMACORE INSULATED STEEL DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click
More informationResidential Garage Doors Miami-Dade Hurricane Ready. Miami-Dade Hurricane Ready Residential Garage Doors
Residential Garage Doors Miami-Dade Hurricane Ready Miami-Dade Hurricane Ready Residential Garage Doors 800-472-9667 www.raynor.com Miami-Dade Hurricane Ready Hurricane Ready Residential Garage Doors Determine
More informationESU-130S. Thin-line Louver Frameless. Application and Design. Standard Construction. Options (at additional cost)
Application and Design Frameless is a frameless ultra thin-line stationary louver commonly used for interior or exterior applications where high free area and low airflow resistance is required. The narrow
More informationMarch 26, 2017 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES
March 26, 2017 Page 1 DESCRIPTION PRODUCT FEATURES Factory fabricated metal wall siding/cladding with related flashings and accessory components. Online brochure available at: http://www.lenmak.com BASIC
More informationLittlies. Willplay s Littlies range offers floor. Cool activities for little kids!
Littlies Cool activities for little kids! Willplay s Littlies range offers floor based activities that promote safe play while challenging the little ones imaginations. From cubby houses to interactive
More informationLouvers Selection, Design Considerations and Details Written by Matt Trentham, R.L. Craig Company, Inc.
Louvers Selection, Design Considerations and Details Written by Matt Trentham, R.L. Craig Company, Inc. Louvers are a basic and simple part of many HVAC systems and buildings, but they are often overlooked
More informationMILLENNIUM METALS, INC TEST REPORT
MILLENNIUM METALS, INC TEST REPORT SCOPE OF WORK WIND DRIVEN RAIN RESISTANCE TESTING OF MMI 26 GA OFF RIDGE VENT WITH DETACHABLE BAFFLE REPORT NUMBER H7685.03-450-18 R1 TEST DATE 11/29/17 ISSUE DATE 12/18/17
More informationSECTION MANUFACTURED ROOF EXPANSION JOINTS
SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationDecks/Liners. structural steel decks and liner trays.
Decks/Liners structural steel decks and liner trays Decks/Liners Structural steel decks and liner trays Features and Benefits Structural decking offers a simplified method of roof construction by dispensing
More informationROOF DRAINS TABLE OF CONTENTS
Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF
More informationMarch 26, 2017 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES
March 26, 2017 Page 1 DESCRIPTION PRODUCT FEATURES Factory fabricated metal wall or soffit cladding with related flashings and accessory components. Online brochure available at: http://www.lenmak.com.
More informationESF-145. Thin-line Louver Flat Blade. Application and Design. Standard Construction. Options (at additional cost)
Application and Design Flat Blade is a thin-line stationary louver commonly used for interior or exterior applications where high free area and low airflow resistance is required. The narrow depth makes
More informationSignature Series 5 Lap SECTION ALUMINUM WINDOWS
Signature Series 5 Lap SECTION 08 51 13 ALUMINUM WINDOWS PART 1 GENERAL 1.01 SUMMARY A. Related Documents: Conditions of the Contract, Division 1 - General Requirements, and Drawings apply to Work of this
More informationENERGY EFFICIENT RETROFIT MEASURES GUIDE
ENERGY EFFICIENT RETROFIT MEASURES GUIDE ENERGY EFFICIENCY RETROFIT PROGRAM FOR LOW-INCOME HOUSEHOLDS CO-OP COMPONENT For nonprofit continuing housing cooperatives listed in the Québec Enterprise Register
More informationEffective Date: Jan. 1, 2016 DURAFLO SECTION ROOF VENTS WE KNOW VENTILATION
Effective Date: Jan. 1, 2016 DURAFLO SECTION 077200 ROOF VENTS WE KNOW VENTILATION Extreme weather conditions across the country has increased the demand for a weather resistant vent. Duraflo has developed
More informationCentral Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS
Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Part 1 General 1. RELATED SECTIONS 1. Section 07 92 10 Joint Sealing 2. Section 08 71 00 Door Hardware 2. REFERENCES 1. American Society
More informationSECTION GUTTERS AND DOWNSPOUTS
SECTION 07712 GUTTERS AND DOWNSPOUTS PART 1 GENERAL 1.1 SECTION INCLUDES A. Gutters and Downspouts. B. Related Accessories. 1.2 RELATED SECTIONS A. Section 07611 - Sheet Metal Roofing. B. Section 07220
More informationThermacore COLLECTION
Thermacore COLLECTION Premium insulated garage doors deliver maximum thermal efficiency and design flexibility. Image above: Model 194 8 high, Standard panel, White finish, Stockton 1 windows Cover image:
More informationExternal Coating Chart
Insulated Panel Envelope Systems Roof Wall Façades Fabrications External Coating Chart External Finishes & Colours 02 External Coating Colour Chart Introducing Kingspan's Colours Kingspan provides a large
More informationGUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM
1 GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials, and services to furnish and install VERSA SHIELD Window
More informationALUMINIUM SAND TRAP LOUVER : CONSTRUCTION
ALUMINIUM SAND TRAP LOUVER : CONSTRUCTION RUSKIN sand trap louvers are specially designed to separated the sand and dust from the air. It is effective and necessary to apply for ventilations and inlet
More informationPREFA Aluminiumprodukte GmbH Page 1 of 21
Tender Specifications 120901 PREFA Shingles_2012 ---------------------------------------------------------------------------------- 01. Text GENERAL PRELIMINARY REMARKS Roof ----------------------------------------------------------------------------------
More informationDyno Test Rooms Professional Chassis, Engine & Specialty Test Rooms for the PowerSports & Product Testing Market
INC s Professional Chassis, Engine & Specialty Test Rooms for the PowerSports & Product Testing Market Proven performance Contains noise and removes exhaust Rugged modular steel panel construction Safe
More informationESU-150. Thin-line Louver Thin-line Blade. Application and Design. Standard Construction. Options (at additional cost)
Application and Design Thin-line Blade is a thin-line stationary louver commonly used for interior or exterior applications where high free area and low airflow resistance is required. The narrow depth
More informationLouis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1
Louis Armstrong New Orleans International Airport NOAB Project # 8910-01233 PART 1 - GENERAL SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS 1.1 RELATED DOCUMENTS A. Drawings and general provisions
More informationSECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM
SECTION 13 34 21 - STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM PART 1 - GENERAL 1.1 DESCRIPTION A. The structural retrofit roof sub-framing system will provide support for a new metal roofing system constructed
More informationCan be installed. sloped roofs. on all. toutes les toitures. S adapte à 18 / 12 56º. 2/12 to 18/12. from
2 / 12 9º S adapte à toutes les toitures en pentes allant de 2/12 à 18/12 4 / 12 18º Les ventilateurs Optimum sont conformes aux normes CSA. Optimum s Hattic Ventilator are conform to CSA norms. 8 / 12
More informationSECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM
PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.
More informationSLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017]
[Change these specifications as needed. Use this sample proposal at your own risk. This is a simple, general proposal and is not meant to be a comprehensive proposal for all situations or projects. If
More informationPLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION
DRAINAGE SOLUTIONS SINCE 1908 PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION PROVEN PERFORMANCE ARMTEC.COM
More informationSECTION COMPOSITE EXTERIOR SHUTTERS AND ACCESSORIES
SECTION 10712 COMPOSITE EXTERIOR SHUTTERS AND ACCESSORIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Functional exterior shutters. B. Exterior shutter hardware. 1.2 RELATED SECTIONS A. Section 09900 - Paints
More informationSHEET METAL ROOF TEST REPORT
SHEET METAL ROOF TEST REPORT Introduction The time tested performance of the double lock standing seam and batten seam metal roofing is demonstrated by thousands of squares successfully installed by SMACNA
More informationSPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 5 REINFORCING STEEL. 5.1 General Certification Fabrication...
SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 5 REINFORCING STEEL TABLE OF CONTENTS 5.1 General...5-1 5.2 Certification...5-1 5.3 Fabrication...5-1 5.4 Handling and Storage...5-1 5.5 Field Repair of Epoxy
More informationSapphire Metal Tile Roofing System
Sapphire Metal Tile Roofing System Sapphire Metal Tile Roofing Benefits of Sapphire Metal Tile - Beauty and function - Tile Beauty, Steel Strength, Lasts a lifetime - Excellent long term investment - Pays
More informationThree Great Steel Panels
Three Great Steel Panels Residential Applications Agricultural Applications Commercial Applications Through Fastened Panel Hidden Fastener Panel Color Matched Soffit Color Matched Gutter Color Matched
More informationWorldwide Competence in Plastics. Development by professionals. The long-lasting roof system
en austroplan TPO roof liners l Made of environmentally friendly TPO l High flexibility l Resistant to root penetration l Tearproof and weather resistant l Maintenance free l Long lifetime l Easy and safe
More informationThe under-tile thermo insulating system INSTRUCTIONS FOR CORRECT INSTALLATION
The under-tile thermo insulating system INSTRUCTIONS FOR CORRECT INSTALLATION The under-tile thermo insulating system PHASE 1 STARTING INSTALLATION Pag. 3 NOTE CUTTING THE PANEL Pag. 4 PHASE 2 JOINTS AND
More informationMASTERFORMAT SPECIFICATION
Contact: PFB Manufacturing, LLC Insulspan SIP Plant 9012 East US 223 Blissfield, MI, USA 49228-0026 Phone: 800.726.3510 Plasti-Fab Ltd. Head Office 100, 2886 Sunridge Way N.E. Calgary, AB Canada, T1Y 7H9
More informationSTERLING. Construction & Development Corporation MODULAR BUILD. Cost Competitive System
- Introduction a. What is Modular Build? b. Basic Components c Standard Dimensions d. Uses Cost Competitive System Easy Transportable Modular Build is a Pre-Fabricated highly Insulated Building System
More informationPREFA Aluminiumprodukte GmbH Page 1 of 25
Tender Specifications 120901 PREFALZ Double Standing Seam_2012 ---------------------------------------------------------------------------------- 01. Text GENERAL PRELIMINARY REMARKS Roof ----------------------------------------------------------------------------------
More informationSIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017
SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE Amended 28 August 2017 BRANZ Appraisals Technical Assessments of products for building and construction. Sika (NZ) Ltd PO Box 19 192 Avondale Auckland 1746
More informationSECTION SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Doors B. Track and Framing 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.
More informationVinyl Window Designs Ltd. 550 Oakdale Road Toronto, ON M3N 1W6 SPECIFICATIONS
Vinyl Window Designs Ltd. 550 Oakdale Road Toronto, ON M3N 1W6 DIVISION 08 / SECTION 08560, VINYL WINDOWS SPECIFICATIONS 1.0. Section includes: 1. All windows of the types and sizes as called for in this
More informationWESTECK WINDOWS and DOORS
WESTECK WINDOWS and DOORS SECTION 08565 VINYL (PVC) PATIO DOOR GENERAL Supply PVC patio sliding doors as per approved Shop Drawings. PART 1 1.1 SECTION INCLUDES A. Patio sliding doors 1.2 RELATED SECTIONS
More informationCITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO
SECTION 07220 - ROOF INSULATION PART 1 - GENERAL 1.01 DESCRIPTION A. Work included: The Roofing Contractor will provide all polyisocyanurate insulation and high density wood fiber roof insulation (tapered
More informationSECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.
SECTION 06 12 00 STRUCTURAL INSULATED PANELS ------------------------------------------------------------------------------------------------------------ PART 1- GENERAL ----------------------------- 1.1
More informationSub-construction for Wall-mounted Longlight
modular skylights Sub-construction for Wall-mounted Longlight Subconstruction for Wall-mounted Longlight at 5-40 pitch modular skylights in a wall-mounted longlight solution, can be installed on a sub-construction
More informationCANAL COMPACT & CANAL PLUS. powerful warmth, perfectly integrated
CANAL COMPACT & CANAL PLUS powerful warmth, perfectly integrated Fan assisted technology can be added to these products to provide controllable, very high outputs without cost to the environment High output
More information1 Exam Prep Prov Module: Thermal and Moisture Protection Questions and Answers
1 Exam Prep Prov Module: 27203-13 Thermal and Moisture Protection Questions and Answers 1. The R-value is a measure of the ability of a material to. A. Resist the passage of moisture B. Resist heat conduction
More informationInstallation Instructions
Installation Instructions SAVE THESE INSTRUCTIONS Please read this entire manual before you install and use your room heater. Failure to follow instructions may result in property damage, bodily injury,
More informationSiding and Soffit Installation Guidelines
Siding and Soffit Installation Guidelines email web phone 07 46 16 Longboard Siding & Soffit INTRODUCTION INSTALLATION GUIDELINES NOTE: These instructions are prepared for persons experienced in the field
More informationThermalShell Modular Insulated Pre-Cast Panels
412 N. California St. Building #2 Sycamore IL, 60178 Phone: 815.899.0224 Fax: 815.899.0226 E-mail: info@thermalshell.com Web: www.thermalshell.com ThermalShell Modular Insulated Pre-Cast Panels Construction
More informationUtility Cabinet System (UCS)
(UCS) The Ultimate in Stainless Steel Modular Walls UCS: Eliminates the need and the costs of constructing a traditional wall Provides easier access and faster installation of the utilities compared to
More informationCorrosion Considerations PP C
Corrosion Considerations Objectives Rust Protection Methods Paint Standards Chemical Corrosion Stainless Steel Protective Coatings Interior Protection Metal Corrosion, Rust Corrosion presents a major threat
More informationInsulating Attics & Crawlspaces. Roger Morrison, PE, RRC NCFI Polyurethanes
Insulating Attics & Crawlspaces Roger Morrison, PE, RRC NCFI Polyurethanes Unvented vs. Vented Vented Space is vented to the outside Space is unconditioned Unvented Space does not communicate with outside
More informationPRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
More informationMASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.
SECTION 085113 - ALUMINUM WINDOWS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes fixed and operable aluminum-framed windows. 1.2 PERFORMANCE REQUIREMENTS A. General: Provide aluminum windows capable
More informationThe better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs November 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements....................................
More information1 BASE HOME CONSTRUCTION SPECIFICATIONS: TOWNHOMES 5-13-2015 Note: Specifications noted below may change based on selected options. Verify upgrades from the base specifications with the option sheets and
More informationSECTION HVAC GRAVITY VENTILATORS
SECTION 23 37 23 HVAC GRAVITY VENTILATORS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More information6 Drainable Louver. Update to Louvers Catalog C-1.0. Catalogue Page 2 Page 7. Page LP-13. Submittals Drawing
6 Drainable Louver Section Page Number Catalogue Page 2 Page 7 Performance Data Page LP-12 Page LP-13 Submittals Drawing 237947 Update to Louvers Catalog C-1.0 April 2010 Louvers General Product Overview
More informationCorium Brick Rainscreen System Specifications
CORIUM BRICK RAINSCREEN SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Work Included: The Work of this Section shall include but not be limited to the following: 1. Corium brick plates 2. Galvanized and coated
More informationTrims for flat roofing. GRP Trims for flat roofing
Trims for flat roofing GRP Trims for flat roofing SUITABLE FOR BOTH NEW BUILD AND REFURBISHMENT PROJECTS ROOFLOCK GRP Trims for flat roofing Maintenance free and easy to install Lightweight, with superior
More informationARCHITECTURAL SPECIFICATION: PLAYGROUNDS EPDM Rubber (Poured-in-Place)
ARCHITECTURAL SPECIFICATION: PLAYGROUNDS EPDM Rubber (Poured-in-Place) GENERAL REQUIREMENTS Fortco Limited Playsafe (Poured-in-Place) is a seamless play area surface consisting of recycled rubber tire
More informationSECTION mil thickness COLD FLUID-APPLIED WATERPROOFING
SECTION 07 14 16 CCW-MIRASEAL @ 120 mil thickness COLD FLUID-APPLIED WATERPROOFING PART 1 - GENERAL 1.1 SECTION INCLUDES: Installation of waterproofing membrane on surfaces indicated on drawings, consisting
More informationESJ-401RM. Stationary Louver J Blade. Application and Design. Standard Construction. Options (at additional cost)
Stationary Louver J Blade Application and Design is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates J style blades, sloped sill and
More informationPioneer Forced Draft Cooling Tower Specifications
Delta Cooling Towers, Inc. 41 Pine Street P.O. Box 315 Rockaway, New Jersey 07866-0315 Telephone 973.586.2201 Fax 973.586.2243 www.deltacooling.com sales@deltacooling.com Pioneer Forced Draft Cooling Tower
More informationInstallation Guide Wall Panels
Installation Guide Wall Panels Jointless or Dry-Stacked Installation (Read Prior to installation) The MStone system is a jointless / dry-stacked installation where panels and corners fit tightly together
More informationWeatherproofing & Sealing Systems
Weatherproofing & Sealing Systems Weather Barrier & Waterproofing Residential & Commercial Structures New Construction, Remodeling & Repair Low Slope Roofing Membranes Roofing Underlayments Window & Door
More informationTPO and PVC Roof Flashings and Accessories
TPO and PVC Roof Flashings and Accessories FlashCap - Plumbers Flashings Standard sizes only: 1 1 /2, 2 3 and 4 of 25 minutes Cylindrical Plumbing Boots Available in all standard pipe sizes. Hose clamp
More informationLIT-058 ROOFGUARD-2017 The Uncloggable Roof Drain Dome Go to for the most current product specification sheets.
www.mifab.com The Uncloggable Roof Drain Dome ROOFGUARD-2017 Go to www.mifab.com for the most current product specification sheets. DESIGNED, ASSEMBLED AND PACKAGED IN THE USA LIT-058 MIFAB, Inc. 1321
More informationSECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?
SECTION 08360 SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Glazed Aluminum
More informationSECTION G RELIEF VENTS A-0
SECTION G A-0 TABLE OF CONTENTS Thaler Or Equal RV-1A/-RV-1C Relief Vent RV-2A/-RV-2C Relief Vent RV-3A/-RV-3C One Way Relief Vent Relief Vent Specification G-0 G-1 G-2 G-3 G-4, G-5, G-6 WHAT IT TAKES
More informationCASSETTE BS Specification book
CASSETTE BS Specification book Edition: April 2011 ArcelorMittal Construction International Industriestrasse 19 8112 Otelfingen / Zürich Switzerland www.arcelormittal.com/arval PRESENTATION OF THE SYSTEM
More informationALUMINUM SIDING SOFFITS, MOULDINGS AND ACCESSORIES
ALUMINUM SIDING, MOULDINGS AND WWW.DUCHESNE.CA DUCHESNE ALUMINUM SIDING AND COMBINE QUALITY, PRACTICALITY AND GOOD LOOKS. THE PERFECT COMPLEMENT TO VINYL SIDING AND STEEL ROOFING AND SIDING Wide selection
More informationINTERIOR ENVIRONMENT
CHAPTER 12 INTERIOR ENVIRONMENT > SECTION 1201 GENERAL 1201.1 Scope. The provisions of this chapter shall govern ventilation, temperature control, lighting, yards and courts, sound transmission, room dimensions,
More informationSL150 Guide Specification
SL150 Guide Specification This is a suggested guide specification for metal roofing projects where the SL150 panel system is applicable. Questions regarding applicability should be discussed with Union
More informationSECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications
SECTION 07 42 13 INSULATED METAL WALL PANELS ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications PART 1 GENERAL 1.1. Summary The contract drawings indicate
More informationDBI-SALA Uni 8 Overhead Horizontal Lifeline Cable System SECTION HORIZONTAL FALL PROTECTION - OVERHEAD CABLE
SECTION 112429.18 - HORIZONTAL FALL PROTECTION - OVERHEAD CABLE PART 1 - GENERAL 1.1 SECTION INCLUDES A. Provide overhead horizontal cable fall protection system, including end anchors, energy absorbers,
More informationESD-435X. Florida Product Approved Drainable Blade Louver. Application and Design. Standard Construction. Qualified Shapes
Application and Design Florida Product Approved Drainable Blade Louver is a Florida Product Approved stationary drainable blade extruded aluminum louver designed to protect air intake and exhaust openings
More informationSED-501. Sightproof Louver Drainable Blade. Application and Design
Application and Design is a sightproof weather louver designed to protect air intake and exhaust openings in building exterior walls when visual see through prevention is needed. Design incorporates a
More informationESD-635. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)
Application and Design Stationary Louver Drainable Blade is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates drain gutters in the head
More informationPage 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES
2016-03-24 Page 1 SECTION 08360 SECTIONAL OVERHEAD DOORS DESCRIPTION MODEL 900 PRODUCT FEATURES Sectional steel overhead doors, industrial grade heavy duty construction. BASIC USES / RELATED USES Sectional
More informationGENERAL SHALE NATURAL THIN ROCK VENEER Installation Guide. GeneralShale.com
GENERAL SHALE NATURAL THIN ROCK VENEER Installation Guide GeneralShale.com GENERAL SHALE NATURAL THIN ROCK VENEER Page 2 INTRODUCTION - TABLE OF CONTENTS Check local building codes for proper installation
More informationEDK-402. Stationary Louver K Blade. Application and Design. Standard Construction. Options (at additional cost)
Application and Design Stationary Louver K Blade is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates drainable head, K style blades,
More informationThe Uncloggable Roof Drain Dome LIT-058
www.mifab.com ROOFGUARD -018 CERTIFIED MANAGEMENT SYSTEM ISO 9001:015 Go to www.mifab.com for the most current product specification sheets. DESIGNED, ASSEMBLED AND PACKAGED IN THE USA The Uncloggable
More information