1 Platform stair lift PLG7 ORIGINAL-user manual Part 2: Assembly Instruction English Version 2.00 ASCENDOR GMBH Drautendorf Niederwaldkirchen Austria Tel.: Fax:
2 Assembly Instruction Platform stair lift PLG7 Date of issue: January 2015 Version 2.00 Part 2 / 3 of the original user manual My ASCENDOR-partner is: Page 2 Version 2.00 Assembly Instruction PLG7
3 Content 1. Introduction Health and safety regulations Notes for installation Specific demands on the installation fitters Additional information for the fitters Personal safety equipment Schedule of installation Tools required for installation Preparation before commencing installation Setting up (assembly and adjustment) of the travel rails Attaching the travel rails directly to the wall Choosing the correct fixing material Measurement of the first mounting hole Securing the travel rail mounting brackets Attaching the travel rails with stanchions / posts Measurements of the first stanchion / post Fixation of further stanchions / posts Fixation of rail cover panels Mounting the platform stair lift onto the travel rails Installing the battery charger Fitting the limit switches Completing the installation Sample installation drawing Test report after finished installation The further parts of the original user manual are: Part 1: Operating Manual Part 3: Maintenance and Service Manual Assembly Instruction PLG7 Version 2.00 Page 3
4 1. Introduction This assembly instruction is designed to assist you during the installation of the platform stair lift PLG7. Although the information and photographs printed in this manual illustrate a particular stair lift, the description is still relevant for all other installations. Please note that this manual contains instructions for the installation of parts and equipment which are not supplied with all our lifts (optional extras). The instructions in this assembly manual describe equipment and tools which were available at the time of writing. Due to the continuous development of our products, we reserve the right to alter the contents and technical data without consultation or prior warning. This part of the user manual is dedicated to trained installation technicians who are used to the installation of this product. 1.1 Health and safety regulations! N O T E! In the interest of your own well being and the safety of third parties, please observe international health and safety regulations and the applicable national laws at all time.! A T T E N T I O N! This lift is manufactured in compliance with the relevant international and national health and safety directives. However that alone cannot guarantee safety and security. Incorrect operation or misuse of this product can eventually cause heavy injuries of the user or third parties and result in damage to the lift and its surroundings. 1.2 Notes for installation The installation of the platform stair lift may only be carried out by the trained personal of an Ascendor partner. This manual is designed to assist you with the installation and especially during the installation of the travel rails of the stair lift. The travel rails of the stair lift may not be altered (extended or shorted). The stability of the walls, onto which the stair lift is to be mounted, must be assessed on site by a qualified fitter. Ascendor accepts no responsibility and liability for this work. The exact installation dimensions are clearly specified in the drawing delivered with each stair lift and must be observed at all times. A 230 V power socket or supply cable L/N/PE 3x1,5mm² must be either present or fitted at one of the two lift stations (upper or lower station) during the installation. 1.3 Specific demands on the installation fitters The installation fitters must be employed and trained by an Ascendor approved partner. The fitters must be able to assess on site the load bearing capabilities of the walls and supporting elements to which the lift and its equipment will be attached. They must be capable of reading and understanding the provided installation drawings. Ascendor accepts no responsibility or liability for this work. Page 4 Version 2.00 Assembly Instruction PLG7
5 1.4 Additional information for the fitters The weight of the lift varies between 125 and 140 kg, depending on the size of the platform and the number of rechargeable cells supplied. A wheeled trolley or some form of carrying straps to assist in the transport of the lift unit should be made available whenever possible. The travel rail of the stair lift consists of one or more parts which can vary between 1 and 5 meters in length. In case of uncertainty or arising questions, please refer to your Ascendor partner or do not hesitate to call our customer service at +43 (0)7231/ Personal safety equipment During installation it is required to wear personal safety equipment to reduce the risk of injuries. This equipment must be worn at all times during installation. General: additionally required for use of angular grinders or power drill: 2. Schedule of installation Check if the contents are complete and that no transport damages incurred during delivery Check if the actual dimensions of the staircase correspond with those mentioned in the installation drawing. If you find major differences please contact Ascendor. Assembly and adjusting the travel rails Fixing the upper attachment bracket Position and align the travel rails Fasten the travel rails Mounting the platform stair lift onto the travel rails Fitting the limit switches Installing the battery charger Completing the installation Function test of the complete lift unit Assembly Instruction PLG7 Version 2.00 Page 5
6 3. Tools required for installation Ascendor recommends carrying following installation tools with you: Additional light sources for installation work Tape measure Spirit level, short, with digital display Spirit level, long approx. 1500mm One-hand bar clamp Cordless screwdriver incl. extender and drill bits Hand tools: o socket wrench set with extensions and various inserts o Multi-purpose pliers o Wire cutter o Wire stripper o Crimping tool o Screw driver o Screw wrench Power drill incl. concrete drills Drills and tapping drills for threads Angular grinder Vacuum cleaner Draw wire or tape (for fitting electrical cable) 4. Preparation before commencing installation Check the lift unit packaging (wooden crate), the packaging of the travel rails and if applicable, the packaging of support brackets for any signs of damage. If any signs of damage are visible, take some photos immediately and please register them with the haulage company responsible and with Ascendor without delay. Open the wooden crate carefully with a cordless screwdriver. Check that all the contents of the crate are present and undamaged. Remove the cardboard box containing the installation drawing and fitting materials out of the crate. Compare the actual dimensions of the staircase on site with the information in the provided drawing. (Sample drawing see chapter 12). If you find major differences please contact Ascendor. Remove the travel rails from the packaging and check if all the contents are present by comparing the delivery note/packaging slip. Page 6 Version 2.00 Assembly Instruction PLG7
7 5. Setting up (assembly and adjustment) of the travel rails Before attaching the travel rails to the wall or stanchions, measure and adjust the distance A between (upper) handrail and the (lower) rack. You can find the A dimension in the provided assembly drawing. The A-dimension is measured 90 between the inner side of the handrail and the inner side of the rack. After completing the adjustment tighten all bolts! Re-check the A dimension again to be sure that it hasn t changed during tightening of the bolts. 90 to the rail Assembly Instruction PLG7 Version 2.00 Page 7
8 6. Attaching the travel rails directly to the wall 6.1 Choosing the correct fixing material Different fasteners are provided for each installation. In the cardboard box you will find several screws and wall plugs which should be used for the installation of the travel rail and/or stanchions No. Utilisation 1 For wall installation: Fixation of the upper hole of the bracket 2 For wall installation: Fixation of the two lower holes of the bracket 3 For stanchion installation: Fixation of the stanchion on the floor 4 For stanchion installation: Fixation of the upper hole of the bracket on the stanchion 5 For stanchion installation: Fixation of the two lower hole of the bracket on the stanchion Anchor bolts for installation on concrete walls are not included. They have to be provided by the installation fitter on-site. 6.2 Measurement of the first mounting hole Unless otherwise noted on the installation drawing, locate the position of the middle mounting hole first. Use the given X and Y dimensions. (See sample drawing chapter 12) Drill a hole for the first mounting point and attach the travel rails to the wall with the appropriate fasteners. Select the correct fasteners to correspond with the properties of the supporting wall. The fitter must decide on site which materials are appropriate and the fasteners that have to be used. Ascendor accepts no responsibility or liability for this work. The following fasteners are recommended: for concrete walls: e.g. HSA Anchor (Hilti) for solid brick walls: Masonry bolts 12x180 with wall plugs for cavity brick walls: e.g. chemical adhesive HY 20 (Hilti) or equivalent Page 8 Version 2.00 Assembly Instruction PLG7
9 The next step is to adjust the angle of the travel rails in accordance with the information given in the installation drawing (e.g. 32,7 ). The easiest way to do this is to adjust the rails with the aid of a one-hand bar clamp or a stanchion to match the dimension H (edge of the step until middle of the lower rack). Please note that the dimension H is only a standard clearance and small deviations may occur, but it should not be underrun, otherwise there is a risk of collision with the steps. It s therefore essential that the angle of the travel rails corresponds with the information on the drawing! It s important to ensure that the mounting brackets between handrail and rack are mounted in a vertical position! Assembly Instruction PLG7 Version 2.00 Page 9
10 Once the angle has been correctly adjusted, the installation of the travel rails can be continued.! A T T E N T I O N! Ensure that the mounting brackets are all positioned vertically. The clearance between the middle of the (lower) rack and the edge of the steps shall under no circumstances be lass then the dimension H provided in the installation drawing. Failure to observe this will result in collision between the lift and the stairs! 6.3 Securing the travel rail mounting brackets Fix the travel rail on each bracket three times to the wall / stanchion. Use countersunk screws at the upper hole! The middle and lower screws between the handrail and rack are not allowed to protrude more than 20mm from the bracket! Page 10 Version 2.00 Assembly Instruction PLG7
11 7. Attaching the travel rails with stanchions / posts 7.1 Measurements of the first stanchion / post Unless otherwise noted on the installation drawing, locate and mark the dimension X (clearance from the edge of the uppermost step to the middle of the supporting bracket) clearly on the wall or step. Position now the stanchion with the correct length. Unless otherwise noted on the installation drawing numbering of the stanchions begins at the bottom (Stanchion A = lowest stanchion). Ensure that the stanchion is correctly positioned (clearance from wall, clearance between lowest step to middle of stanchion). Once this is completed, the fixing holes for the stanchion can be drilled. Depending on the floor consistence use following fixing material to attach the stanchion base plate: for concrete e.g. HSA Anchor (Hilti) Masonry bolts 12x120 with wall plugs chemical adhesive HY 20 (Hilti) or equivalent! A T T E N T I O N! The stanchions have to be securely fastened at all four holes! 7.2 Fixation of further stanchions / posts After securing the stanchion on the floor the first threaded hole for the mounting bracket can be tapped. Locating the position of the hole follows the same principle described in chapter 7.1. The picture shows the (standard) forms of the stanchion base plate which are used for the installation of the travel rails. To attach the mounting bracket onto the stanchions use the M10x30 screws provided with the lift. Attach the bracket to the uppermost hole using countersunk screws, and hexagonal headed bolts for the two lower holes. Once the first bracket has been secured, the travel rails must be aligned and the angle must be adjusted. This can be achieved simply by holding the bracket in place against the stanchion by the aid of a one-hand bar clamp (be careful not to damage the surface of the stanchion while doing this). Once the angle has been adjusted, check the clearance between the rack and the edge of the steps. This value is not allowed to be less than the dimension H, otherwise the lift will collide with the stair! The position of the rest of the stanchions is predetermined by the position of the mounting brackets. Please ensure that the threaded holes are drilled in the middle of the stanchion and that the stanchions are in a vertical position! Assembly Instruction PLG7 Version 2.00 Page 11
12 7.3 Fixation of rail cover panels The rail cover panels are used to prevent injuries caused by touching the rails whilst the carriage is moving on the rails. The panels are fitted in between the stanchions using the delivered holders. Also a fall protection is provided by those panels. To distinguish the single panels measure the main dimensions (length, width) and compare them with the provided drawing. Unless otherwise noted on the installation drawing numbering of the panels starts always on the bottom of the rails (panel 1 = between stanchion A and stanchion B). Following safety distances should be considered: The gap between panel and stair stringer should be less than 3cm The upper edge of the sheet should be 5-6cm higher than the (upper) handrail Hold the sheet so that the above mentioned safety distances are observed and mark the first fixing hole on the stanchion. The position of the threaded M6 hole can be chosen by the predrilled hole in the panel. After that attach the panel to the holder, align the panel and fix the 2 nd part of the holder. Once done fix the remaining panel holders. Ensure that all panels are mounted on the same height, to have a consistent good looking general view. Page 12 Version 2.00 Assembly Instruction PLG7
13 8. Mounting the platform stair lift onto the travel rails Two people will be required to install the lift, do not attempt this alone! If carrying straps are used, these may be attached to the safety bars. Only carry the lift on the points indicated on the photo to the right!! A T T E N T I O N! Do on no account carry the lift using the handle bar! Firstly turn on the red switch (main fuse) in the fuse box located at the backside of the lift. Please be aware that the brass charging contacts are removed before positioning the lift onto the rails. If all preparations are done so far you can insert the lift onto the travel with support of a 2 nd person.! A T T E N T I O N! Please ensure that the plastic covers on the back side of the lift get not scratched or damaged! If the travel rail is already mounted you can install the lift from the top side of the rail. By pressing down button on the wall mounted or handheld controls you can run the lift onto the rails.! A T T E N T I O N! Make sure that the gear of the emergency break and the (lower) rack fit into one another. If the teeth don t fit together the emergency break can be damaged! 9. Installing the battery charger The battery charger unit IP 30 should not be installed in the open air but must be fitted inside the housing supplied for this purpose. The position of the charger is left to the discretion of the operator. It can be positioned near the upper or lower station. Check the LED of the charger to see whether the batteries are being recharged. An orange LED shows that the batteries are charged at the moment. Assembly Instruction PLG7 Version 2.00 Page 13
14 10. Fitting the limit switches Draw in the brown charging cable with a draw wire or tape inside of the handrail between the two stations. After that run in the brown charging cable through the white charging point holder and connect it on both stations with the brass bar. The next step is to connect the plus terminal of the battery charger with the brass bar. The minus terminal of the battery charger is connected together with the hexagon fixing screw of the charging point holder onto the handrail. Finally fix the charging point holder onto the handrail, the fixing holes are already pre drilled. The brass bar must be fixed to the charging point holder using plastic screws. The final stopping position of the lift at both the upper and the lower station can be regulated by altering the position of the brass bar on the white charging point holder. The brass bar can be moved up or down the plastic bracket depending on the required final stopping position. Page 14 Version 2.00 Assembly Instruction PLG7
15 11. Completing the installation Please ensure that the following steps are carried out and the last small details of the lift installation are completed: Fit the end caps to the (upper) handrail For stanchion installation, fit the provided plastic caps into the top of them Install the wall mounted operating units (if included in the scope of delivery) Wall mounted operating units should be fixed at a height of approx. 90cm, besides there should be enough space (more than 1m) between the wall mounted operating unit and the parked lift Attach the quick start guide (sticker) Attach anti-slip tape onto the platform (optionally) Assembly Instruction PLG7 Version 2.00 Page 15
16 12. Sample installation drawing Page 16 Version 2.00 Assembly Instruction PLG7
17 13. Test report after finished installation OK Fail Function control using the remote control (handheld or wall mounted) Travel up / down O O Platform open / close O O Function test of the key switch (only for wall mounted remote controls) O O Function control using the onboard control Travel up / down O O Function control for safety equipment Limit switch, top O O Limit switch, bottom O O Pressure sensitive contact panel (platform underside) O O Emergency stop button O O Switch function test of the access ramps open (travel up / down) O O Switch function test of the access ramps closed (travel up / down) O O Volume test for acoustic alarm O O Shutdown when safety bars are opened while the lift is in motion O O Emergency travel release button (safety bars half open) O O Emergency folding button O O Shutdown when current overload at platform motor O O Function control for mechanical parts and software Access ramps open and close completely O O Safety bars open and close completely O O Platform open and close completely O O Check battery charger function O O Date, Name Signature Assembly Instruction PLG7 Version 2.00 Page 17
On-roof system Tau Installation manual
On-roof system Tau Installation manual 810-0052 Table of Contents 1 Introduction 1 1.1 Short description 1 1.2 Intended use 1 1.3 Standards and guidelines 1 1.4 About these instructions 1 Tau The innovative
More informationConergy SolarFamulus II
Conergy SolarFamulus II Installation manual www.conergy.com Table of Contents Table of Contents SolarFamulus II for universal use on flat roofs 1 Introduction 1 1.1 Short description 1 1.2 Intended use
More informationProtective Capony RTC-16
Protective Capony RTC-16 ASSEMBLY AND OPERATION MANUAL Protective Canopy RTC-16 Assembly and Operation Manual CONTENT: 1 APPLICATION...3 2 OPERATION CONDITIONS...3 3 TECHNICAL SPECIFICATIONS...3 4 DELIVERY
More informationINSTALLATION GUIDE Sika SolarMount 1 Exposition East West
Exposition East West CONTENTS 1 Notes on the Sika SolarMount 1 system (Exposition East West) for PV solar arrays 3 2 Setting up on site 3 3 Required Tools for mounting Sika SolarMount 1 to Sika roofing
More informationMOUNTING SYSTEM FOR PITCHED ROOF WITH TILES. mounting system for pitched roof with tiles for solar panels in landscape setup. Rev
MANUAL EN MOUNTING SYSTEM FOR PITCHED ROOF WITH TILES mounting system for pitched roof with tiles for solar panels in landscape setup ESDEC BV 2016 TABLE OF CONTENT 1. Introduction 1 2. General installation
More informationInstallation Instructions
Installation Instructions Flue Gas System Basic Kit GA-K - Chimney Flue Gas System for GB125 Oil Condensing Boiler For trained and certified installers Please read carefully prior to installation. 6 720
More informationUS Pool Lift Model #114 (Independence) Installation Guide
US Pool Lift Model #114 (Independence) Installation Guide This manual has been provided to assist with lift installation. For further assistance please contact your authorized US Pool Lift dealer. Toll
More informationAxiom. SURFACE MOUNTED ARRAY Patient Headwall. Installation Guidelines. Installation Instructions.
Axiom www.hsiheadwalls.com SURFACE MOUNTED ARRAY Patient Headwall Installation Instructions Installation Guidelines Tel: 925.427.7800 Fax: 925.427.0800 support@hsiheadwalls.com Hospital Systems Inc. 750
More informationMounting systems for solar technology
Mounting systems for solar technology ASSEMBLY INSTRUCTIONS S-DOME SYSTEM GB TABLE OF CONTENTS TABLE OF CONTENTS THE COMPANY SAFETY REGULATIONS MATERIALS REQUIRED TOOLS REQUIRED ASSEMBLY 3 4 5 8 9 Table
More informationInstallation Manual. Orion. TL-3 Steel Barrier. VHD (v2)
Installation Manual Orion TL-3 Steel Barrier VHD (v2) 300914 Table of Contents Orion Introduction.......... 3 Limitations & Warnings. 4 Before Installation..... 3 System Design & Design Considerations
More informationPATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge
Assembly Manual 8x9 PATENTS ARE PENDING Approximate Size 7640303 Storage Area Building Dimensions Exterior Dimensions Roof Edge to Roof Edge Interior Dimensions Wall to Wall Sq. Ft. Cu. Ft. Width Depth
More informationSECTION I -- IRONWORK
SECTION I -- IRONWORK CONTENTS PAGE 1. GENERAL... I-2 1.1. Introduction... I-2 2. REQUIREMENTS... I-2 2.1. General... I-2 2.2. Auxiliary Framing... I-2 2.3. High Seismic Risk Zone Requirements... I-3 2.4.
More informationVPL-3200B Residential Vertical Platform Lift Technical Specifications
Page 1 of 5 VPL-3200B Residential Vertical Platform Lift Technical Specifications MODEL NUMBER: VPL-3200B Series: Models VPL-3210B, VPL-3212B and VPL-3214B (DC-powered units) U.S. F.D.A. CLASSIFICATION:
More informationUniversal Tilting TV Mount 32" to 60" Installation Instructions
Universal Tilting TV Mount 32" to 60" Installation Instructions Tiltable LCD / TFT TV Wall Mount Material: 2.0mm Cold Rolled Steel Plate TV size: 32" - 60" Tilt angle: 0-15 degrees Max load capacity: 165
More informationSmarter. Safer. Leaner.
Smarter. Safer. Leaner. Fast Installation and Removal Decrease Leading Edge Exposure by 87% OSHA Compliant Versatile and Reusable Use Perimeter Protection Posts During Construction: At Building Perimeter
More informationMODULAR ACOUSTIC FENCING INSTALLATION GUIDE
MODULAR ACOUSTIC FENCING WWW.QUICKBUILTSYSTEMS.COM.AU INSTALLATION GUIDE INTRODUCTION THE QUICKBUILT FENCE SYSTEM IS A SMARTLY DESIGNED MODULAR SYSTEM EASY AND FAST TO INSTALL AND COST EFFECTIVE. // THE
More informationYOUR STEP-BY-STEP GUIDE TO THE PERFECT INSTALLATION. Non-Lit Magnifying Mirrors
YOUR STEPBYSTEP GUIDE TO THE PERFECT INSTALLATION NonLit Magnifying Mirrors you can view our complete range online, WWW.THERMOGROUP.COM.AU Thank you for choosing a Thermogroup product. Our commitment to
More informationGroundTrac. Installation Manual
APPLICATION: The GroundTrac system is designed with a minimum amount of installed footings at greatly reduced labor. The system integrates with ordinary 1-1/2 schedule #40 galvanized water pipe. This ground
More informationFITNESS PLAYGROUND ITEM NO: 8010
FITNESS PLAYGROUND ITEM NO: 8010 OWNER S MANUAL CAUTION: This unit is designed to be used safely by up to 4 children between the ages of 3 years to 8 years old with a maximum weight of 100 pounds (45.4
More informationInstallation Instructions
Installation Instructions Dynarail Safety Ladder System Corrosion Resistant Nonconductive Fire Retardant High Strength-To-Weight Ratio Long, Low Maintenance Life Meets OSHA, BOCA & Other Building Code
More informationMounting instructions
Mounting instructions novotegra for tile roofs top-fix I TABLE OF CONTENTS 1 Notes... 1 2 Maintenance of the mounting system... 3 3 novotegra for tile roofs... 3 4 System components, tools and equipment...
More informationBINAR Quick-Lift System
BINAR Quick-Lift System Install and Training Original Document - July 1, 2015 1 What to expect The installation, set-up, and training process takes an average of 1.5 days (12 hours) per unit. On the first
More informationAqua Swing Tub Door & EX/RT Panel
Aqua Swing Tub Door & EX/RT Panel TUB DOOR AND PANEL INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest
More informationInstallation Instructions/Operation and Maintenance Manual. Models PLG-60 PLG-72. PS DOORS Contact Information. Website psdoors.
Rev. 091416 Pallet Gate Installation Instructions/Operation and Maintenance Manual Models PLG-60 PLG-72 Table of Contents Product Information...2 Installation Instructions...3 Operation...6 Inspection
More informationINSTALLATION GUIDE Tranquil Mount Model: TMO400A
ISTALLATIO GUIDE Tranquil Mount Model: TMO00A Support 32" to 50" Screens Load Capacity: 13.2~65 lbs (6~30 kg) VESA And on-vesa compatible 100mm x 100mm 200mm x 100mm 300mm x 100mm 00mm x 100mm 200mm x
More informationLadders and scaffold systems
Ladders and scaffold systems Customised-solutions for railway vehicles For each application the right solution! www.krause-systems.com Introduction Business Portrait KRAUSE-Werk GmbH & Co. KG For more
More informationSECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT
SECTION 230548 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Elastomeric Isolation pads. 2. Elastomeric Isolation mounts. 3. [Freestanding] [Restrained] [Freestanding and restrained]
More informationModel # 338S-OP. 9/30/2011 Page 1 of 13
Model # 338S-OP 9/30/2011 Page 1 of 13 9/30/2011 Page 2 of 13 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationASSEMBLY INSTRUCTIONS for DATASAFE TM HX and HX FRONT TERMINAL UBC BATTERY RACKS
US-HXRACK-IM-002 ASSEMBLY INSTRUCTIONS for DATASAFE TM HX and HX FRONT TERMINAL UBC BATTERY RACKS Read all instructions carefully and observe all warnings before installation. See Installation, Operation
More informationINSTALLATION INSTRUCTIONS ENGLISH
INSTALLATION INSTRUCTIONS ENGLISH Safety instructions 04 General notes 07 Material & tool requirements 08 System overview 10 installation of CREODUR 11 Maintenance 22 04 INTENDED USE Creotecc mounting
More informationBESTMOVE STANDING TRANSFER AID
BESTMOVE STANDING TRANSFER AID L.L.C. MODELS BestMove 400 BestMove 450 PRODUCT FEATURES *BestMove 450 shown Ensure the product has been assembled according to the instructions in this manual. OPERATING
More informationFixed LCD TV/Monitor Mount 10" to 24" Installation Instructions
Fixed LCD TV/Monitor Mount 10" to 24" Installation Instructions IMPORTANT: If you don't understand the installation instructions, please consult an installation specialist. 04-0525C 1 Caution This mount
More informationROOF MOUNT KIT OWNERS MANUAL
ROOF MOUNT KIT OWNERS MANUAL Made in the USA by: Primus Wind Power, Inc. 938 Quail St. Lakewood, CO 80215 Phone: (303) 242-5820 www.primuswindpower.com AIR is a trademark of Primus Wind Power, Inc. ROOF
More information6032 SH 3P Residential Shower Installation Instructions Gelcoat & Solid Surface Bathware
Tools/materials you might need for proper installation 6D galvanized screws 100% silicone caulking caulking gun acrylic latex caulk shims tape measure 1/8 drill bit Phillips screw driver cardboard china
More informationModel: LoLander Series Truck Scale Model: LL FT Model: LL FT Installation, Set-Up and Operation Manual
SCALE WORKS, INC. Model: LoLander Series Truck Scale Model: LL8035-10FT Model: LL8035-11FT Installation, Set-Up and Operation Manual Cambridge Scale Works, Inc. P.O. Box 670 Honey Brook, PA. 19344 (800)
More informationModel # 158-P4. 12/12/2013 Page 1 of 11
Model # 158-P4 12/12/2013 Page 1 of 11 2/12/2013 Page 2 of 11 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationPE/PH. Product Data Parking Pallet. longitudinally shifting. Parking Pallet PE/PH
of 5 Car Parking Pallet PE/PH Warning light or support Product Data Parking Pallet PE/PH longitudinally shifting CONFORMITY DH 9.5 B Direction of movement 32 : All space requirements are minimum finished
More informationLAHAINA. Lahaina Showerspa Model #1030 Installation Instructions
LAHAINA Lahaina Showerspa Model #1030 Installation Instructions Lahaina ShowerSpa Model #1030 Please Read The Following Instructions COMPLETELY Before Beginning! Our goal is to ensure your installation
More informationInstallation. Smart-UPS VT in Parallel kva 380/400/415 V 208/220 V 200/208 V
Installation Smart-UPS VT in Parallel 10-40 kva 380/400/415 V 208/220 V 200/208 V Contents Safety... 1 IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS.............................. 1 Prepare for
More informationModel # 800SM-PS3. 8/3/2016 Page 1 of 8
Model # 800SM-PS3 8/3/2016 Page 1 of 8 /3/2016 Page 2 of 8 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationFall Protection Guardrails
Fall Protection Guardrails XTP Installation Manual English - Fall Protection XTP Installation Manual - Version 3.0 Contents Fall Protection Guardrails 1.0 Introduction 2 1.1 Fall Protection by XSPlatforms
More informationPlanning and installation instructions
Planning and installation instructions Stofix Oy Ahlmaninkatu 2 E 40100 Jyväskylä Finland stofixgroup@stofix.com www.stofix.com 2 PLANNING AND INSTALLATION INSTRUCTIONS... 1 1 General... 3 2 Project Design...
More informationModel # 238HS-P8. 4/27/2011 Page 1 of 11
Model # 238HS-P8 4/27/2011 Page 1 of 11 4/27/2011 Page 2 of 11 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationGeneral Guidelines. Tools Required. Instructions for Part # SC500-AF. Safety
Instructions for Part # SC500-AF General Guidelines It is the user s responsibility to read and follow all instructions. Keep these instructions with the product at all times and review before each use.
More informationImportant: Before You Start
Advantage ICF System Advantage ICF System TM Field Guide Important: Before You Start Does Your Building Inspector Know You Are Building with the Advantage ICF System? You are required to check with your
More informationModular Coldroom Installation Manual
Modular Coldroom Installation Manual May 2005 Disclaimer: The information contained in this installation guide is provided "as is". Bromic Pty Ltd does not warrant the accuracy, adequacy or completeness
More informationMounting instructions. novotegra for trapezoidal metal - roof parallel
Mounting instructions novotegra for trapezoidal metal - roof parallel I TABLE OF CONTENTS 1 Notes... 1 2 Maintenance of the mounting system... 3 3 novotegra for trapezoidal metal - roof parallel... 3 4
More information1. GENERAL INFORMATION CAUTIONS AND GENERAL NORMS DESCRIPTION AND INTENDED USE MARKING OF DTW WEIGHBRIDGES...
INDEX 1. GENERAL INFORMATION... 3 2. CAUTIONS AND GENERAL NORMS... 4 3. DESCRIPTION AND INTENDED USE... 5 4. MARKING OF DTW WEIGHBRIDGES... 5 4.1 TECHNICAL AND METROLOGICAL MARKING OF WEIGHING BARS...
More informationSchüco Mounting System MSE 210 Mounting on trapezoidal roofing
Solar products Schüco Mounting System MSE 210 Mounting on trapezoidal roofing English Schüco Installation instructions: Installation instructions: MSE 210 trapezoidal roof Art. No. 259 713 08.2009-02 Printed
More information1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS
Model # 349S-P6 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic coated elements. Ultra Play guarantees all
More informationAmerican Metal Specialties, Inc.
American Metal Specialties, Inc. www.cablerailings.com (253) 272-9344 (253) 627-3843 Fax PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 05 73 00 STAINLESS STEEL ORNAMENTAL HANDRAILS AND RAILINGS For best
More informationSYSTEM S7-RHOMBOS INSTALLATION MANUAL
SYSTEM S7-RHOMBOS INSTALLATION MANUAL GENERAL INFORMATION GENERAL INFORMATION This assembly manual addresses all metal ceilings manufactured by durlum. The different sections describe the related/relevant
More informationRaised Basement. Mechanical Installation Guide
R Raised Basement Mechanical Installation Guide Ensure masonry work is correct. If recessed, the depth must be 14 inches deep unless otherwise specified for a custom application. Width and length may vary
More informationLiner Replacement Instructions:
Liner Replacement Instructions: Before beginning the replacement procedure... Be sure to disconnect electrical service to all of your electrical components of the pool. Use extreme caution when working
More informationModel # 358H-PR. 4/8/2011 Page 1 of 12
Model # 358H-PR 4/8/2011 Page 1 of 12 4/8/2011 Page 2 of 12 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationHoesch isorock vario Installation recommendations
A company of ThyssenKrupp Steel 1/12 D tk Info 2.4.2 5.2005 1 Table of contents Page 1. Regulations / Directives 2 2. Delivery / Unloading 3 3. Storage on the site 4 4. Preparation for installation 4 5.
More informationHELIOSTAR 252, 218 HORIZONTAL, FREE INSTALLATION
HELIOSTAR 252, 218 HORIZONTAL, FREE INSTALLATION INSTALLATION INSTRUCTIONS ENERGY AND SANITARY SYSTEMS Installation requirements General requirements The free-standing installation set is to be used for
More informationAQUATIC ACCESS EQUIPMENT
GALLATIN LIFT 27450 20400 27400 Spectrum Lifts come standard clockwise rotation. Specify when ordering. Gallatin Swim-Lift WP400 by Spectrum The Gallatin is a Stainless Steel, water powered lift with a
More informationSEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets
SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets Seismic Frame Two-Post Rack Page 11-3 Seismic Protection Products - Racks Page 11-6 Seismic Protection Products - Runway Page 11-8 Seismic
More informationThank you for purchasing our product. *Please read these instructions and follow them step by step.
PAGE 1 OF 5 PORTA-DOCK, INC. AD01- DS 4'x 16'SW-AA - AP01- DS 4'x 16'SW-APD AW01- DS 4'X 16'SW-CPD ALUMINUM PORTA-DOCK *For Beige Decking Add the Letter B to the Model* Thank you for purchasing our product.
More informationASSEMBLY INSTRUCTIONS
ASSEMBLY INSTRUCTIONS for the vehicle barrier system KREMSBARRIER 2 RH2B for pile-drivable subgrades Performance class in accordance with EN 1317-2: Containment level: Impact severity level: Working width:
More informationMounting System MCG 3.0 Membrane-Connected Glass. System description
Mounting System MCG 3.0 Membrane-Connected Glass System description SUNOVA MCG 3.0 System Fields of application: Not suitable for: (please inquire for other SUNOVA systems) The SUNOVA MCG 3.0 system is
More informationModel # 358-R48. 7/7/2011 Page 1 of 11
Model # 358-R48 7/7/2011 Page 1 of 11 7/7/2011 Page 2 of 11 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationINSTALLATION MANUAL Accordion Gangplank Model No. FBL-1000
INSTALLATION MANUAL Accordion Gangplank Model No. FBL-1000 PLEASE READ THE ENTIRE CONTENTS OF THIS MANUAL PRIOR TO INSTALLATION AND USE OF THE ACCORDION GANGPLANK. BY PROCEEDING, YOU AGREE THAT YOU FULLY
More informationBESTMOVE STANDING TRANSFER AID
BESTMOVE STANDING TRANSFER AID MODELS BestMove 400 BestMove 450 PRODUCT FEATURES *BestMove 450 shown Ensure the product has been assembled according to the instructions in this manual. OPERATING ASSEMBLY
More informationECONO 200 INPLANT OFFICE
Warehouse Storage & Material Handling Equipment+ ECONO 200 INPLANT OFFICE INSTALLATION & ASSEMBLY INSTRUCTIONS American Surplus Inc. 1 Noyes Ave. East Providence, RI Phone: (800) 989-7176 Fax: (401) 434-7414
More informationSECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the
More informationBioPrism Solid Surface
Please read all instructions before installing products. STORAGE & HANDLING: Check for damage that may have occurred during transit. Keep receptor flat on pallet, as it was shipped, until ready to install.
More informationBESTMOVE STANDING TRANSFER AID
BESTMOVE STANDING TRANSFER AID L.L.C. MODELS BestMove 400 BestMove 450 PRODUCT FEATURES *BestMove 450 shown Ensure the product has been assembled according to the instructions in this manual. OPERATING
More informationTroubleshooting Guide 9702 Series
Troubleshooting Guide 9702 Series Satellite Solutions for Mobile Markets 11200 Hampshire Avenue South, Bloomington, MN 55438-2453 Phone: (800) 982-9920 Fax: (952) 922-8424 www.kingcontrols.com 1305-AUTO
More informationST 19 Aluminium Manually Controlled Electric Model
ST 19 Aluminium Manually Controlled Electric Model Operators Manual Issue 5 For correct operation of this autoclave it is essential that the chamber be filled with water up to the height of the studs before
More informationINSTALLATION INSTRUCTIONS
CHIMNEY CONNECTOR WALL THIMBLE MODEL IWT INSTALLATION INSTRUCTIONS Warnock Hersey C US LISTED ULC-S641/UL103 IT IS OF THE UTMOST IMPORTANCE THAT THIS WALL THIMBLE BE INSTALLED ONLY Y IN ACCORD CCORDANCE
More informationModel # 922-S4. 12/18/2013 Page 1 of 8
Model # 922-S4 12/18/2013 Page 1 of 8 2/18/2013 Page 2 of 8 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationSpaVault TM Installation Guide for Bullfrog Spas (7-10 x 7-10 x 38 )
SpaVault TM Installation Guide for Bullfrog Spas (7-10 x 7-10 x 38 ) WARNING - When unpacking SpaVault, DO NOT discard styrofoam pieces, these are not packaging materials. Step 1 Excavation Important:
More informationPanel Jack Pro System BRACING, ALIGNMENT AND SCAFFOLDING EQUIPMENT
IMPORTANT SAFETY INFORMATION FOR USERS OF THE REECHCRAFT, BRACING SYSTEM PLEASE READ BEFORE USE Panel Jack Pro System BRACING, ALIGNMENT AND SCAFFOLDING EQUIPMENT UK Edition 1.3 26/11/2012 1 TABLE OF CONTENTS
More informationSpecialists in Acoustic Flooring and House to Flat Conversions
Sound Solution Consultants Ltd Po Box 755 Capel St Mary Ipswich Suffolk IP9 2WF Tel No: 0845 5212096 Fax No: 0845 5212097 Email: mpconsultservice@aol.com Specialists in Acoustic Flooring and House to Flat
More informationThis guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.
GORBEL PRODUCT SPECIFICATIONS 2010 Gorbel, Inc., P.O., Box 593, Fisher, New York 14453-0593 PHONE: 800-821-0086, FAX: 585-924-6273; WEBSITE: www.gorbel.com November SECTION 41 22 31PRIVATE FREE STANDING
More informationRevision 1 RAM ELEVATORS. Elevator Electrical Planning Guide. RAM Manufacturing Ltd
RAM ELEVATORS Elevator Electrical Planning Guide This guide is intended for people with an understanding of electricity. If you are not, please consult a licensed electrician as errors in application of
More informationSAFETECH 3.2K ST v1.0. User s manual. Opale-Parachutes.com. Please read this manual before first use.
2016 v1.0 User s manual SAFETECH 3.2K ST60 Please read this manual before first use. Thank you for choosing Opale-Parachutes. This user s guide includes all the information you need to assemble and use
More informationThis guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.
SECTION 14651 FREE STANDING JIB CRANE ***** Gorbel, Inc. manufacturers a broad range of material handling cranes including monorail, bridge, gantry, and jib cranes. Numerous work station and industrial
More informationROLLING RACK. Simple Security
Simple Security The graceful design and high security of the Rolling Rack has made this type of bike rack a standard for many schools and communities. The Rolling Rack can be used as a single-sided or
More informationINSTALLATION INSTRUCTIONS ENGLISH
INSTALLATION INSTRUCTIONS ENGLISH Safety instructions 04 General notes 07 Material & tool requirements 08 System overview 10 installation of ALUTEC 12 Maintenance 27 04 INTENDED USE Creotecc mounting
More informationGeneral Construction Supervisory Authority Approval
General Construction Supervisory Authority Approval (Translation of the German original text which has not been checked by the DIBt.) Approval no.: Z-21.8-2018 Period of validity: April 1, 2014 until:
More informationHELIOSTAR 252, 218 VERTICAL, FREE INSTALLATION
HELIOSTAR 252, 218 VERTICAL, FREE INSTALLATION INSTRUCTION MANUAL ENERGY AND SANITARY SYSTEMS Installation requirements General requirements The free-standing installation set is to be used or installing
More informationThree-sided barrier compliant to DIN EN ISO Depending on location, design also as wind protection. Clear height (DH) Three-sided barrier
of 5 Page Car SingleVario 06 Stack Parker 06 50 for vehicle up to 5.00 m = 6 long (50 for vehicle up to 5.0 m 7 long) Depending on location, design also as wind protection. Product Data CONFORMITY 06/06/G63
More informationCORNER ELEMENTS CENTRE SUPPORT ACCESSORY BAG PROJECTION SCREEN BAG. 4 pieces- basic frame 52x52 cm (fig.: including SET UP SUPPORT,optional)
FULLWHITE MANUAL CORNER ELEMENTS 4 pieces- basic frame 52x52 cm (fig.: including SET UP SUPPORT,optional) CENTRE SUPPORT Consists of plug in elements with integrated screw connection ACCESSORY BAG Yellow
More informationBHARAT HEAVY ELECTRICAL LIMITED, JHANSI Specification No.
NOTE : SCOPE : BHARAT HEAVY ELECTRICAL LIMITED, JHANSI Specification No. CRJ/9577 Item No. SP/CRJ/9577/1 & SP/CRJ/9577/2 Location NEW M.G.HOUSE Quantity 2 NOS. DESIGN, MANUFACTURING, SUPPLY, ERECTION &
More informationmediatek mediatek Library and archive shelving systems Taking shelving to the next level BC004.03
mediatek Library and archive shelving systems Taking shelving to the next level BC004.03 mediatek Library and archive shelving systems The Mediatek range of shelving is designed to offer space efficient
More informationSECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM
Page 1 of 6 SECTION 08 32 20 LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS SLIDING DOORS. SECTION INCLUDES OVERHEAD SLIDING TUBE ASSEMBLY, MOUNTING
More informationST XX28 Stainless Steel Thermostatically Controlled Electric Model
DIXONS SURGICAL INSTRUMENTS LTD, 1 ROMAN COURT HURRICANE WAY, WICKFORD BUSINESS PARK WICKFORD, ESSEX, SS11 8YB, UK TEL: +44 (0)1268 764614 - FAX: +44 (0)1268 764615 EMAIL: info@dixons-uk.com - WEB: http://www.dixons-uk.com
More information801-MORD Mordred FIXING: Ground. ORDER No: CUSTOMER: Complied by Date AB 30/06/15 ISSUE ECN DATE SIGN /07/15 AB
CUSTOMER: 0-MORD Mordred ORDER No: FIXING: Ground Complied by Date 0/0/5 ISSUE ECN DATE SIGN 0 7 0/07/5 CUSTOMER: 0-MORD Mordred ORDER No: FIXING: Ground Low tower.m single slide Low scramble net High
More informationRamps Vip Aldime WHAT DO VIP ALDIME RAMPS HAVE THAT OTHERS DO NOT?
Ramps Vip Aldime Vip Vip Aldime, established in 2005, is presently a business project within the field of aluminum. Its professional team proudly bears more than 20 years of experience in this sector.
More informationDiploma in Electrical Installations. (Buildings and Structures) Unit 204 Workbook PRE-ATTENDANCE REVISION V1
2365-02 Diploma in Electrical Installations (Buildings and Structures) Unit 204 Workbook PRE-ATTENDANCE REVISION V1 Welcome This booklet is designed to outline the areas that you will study when you complete
More informationThank you for purchasing the SC-CONVERSION System 500/600 Conversion Kit. This Kit is available in two different versions:
Rev. 1 (Jun 30, 2016) Thank you for purchasing the SC-CONVERSION System 500/600 Conversion Kit. This Kit is available in two different versions: Part # 4K01328-FI SC-CONVERSION Conversion Kit with MEI
More informationAP5K-C Precision AC Double-Pulse Spot Welding Machine User s Manual Shenzhen Will-Best Electronics Co., Ltd
AP5K-C Precision AC Double-Pulse Spot Welding Machine User s Manual Shenzhen Will-Best Electronics Co., Ltd 1 Content 1. Introduction...3 1.1 Functions...3 1.2 Units of AP5K-C...4 2. The Initial Installation
More informationProShell Support Profile for AS/RS and Transfer Cars. An Option for Conductix-Wampfler Conductor Rail Systems
for AS/RS and Transfer Cars An Option for Conductix-Wampfler Conductor Rail Systems Table of Contents System Description 4 System Advantages 5 Technical Data 6 Modular Concept 6 Basic Modules 7 ProShell
More informationROOFING APPLICATION STANDARD (TAS) No. 102(A)-95
ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95 TEST PROCEDURE FOR STATIC UPLIFT RESISTANCE OF MECHANICALLY ATTACHED, CLIPPED, RIGID, ROOF SYSTEMS (For Methods of Mechanical Attachment Excluding Clips,
More informationPATHWAYS FOR COMMUNICATIONS SYSTEMS
270528 PATHWAYS FOR PART 1 GENERAL 1.1 WORK INCLUDED A. Provide all labor, materials, and equipment for the complete installation of work called for in the Contract Documents. 1.2 SCOPE OF WORK A. This
More informationTeraFrame HD Cabinet System Supplemental Installation Guide
TeraFrame HD Cabinet System Supplemental Installation Guide 800-834-4969 techsupport@chatsworth.com www.chatsworth.com 2010 Chatsworth Products, Inc. All rights reserved. CPI, TeraFrame and MegaFrame are
More informationZ5033 E3 Ball joint adapter Mounting instructions
Z5033 E3 Ball joint adapter Mounting instructions Z5033 E3 Ball joint adapter References in the manual This refers to a potentially dangerous situation which may lead to personal injury. This refers to
More information