technical drawings Cutted roof tile Levelling batten Plasma roof tile Plasma eave tile (without ribs on the lower side) C Metalic batten Linkage tile

Size: px
Start display at page:

Download "technical drawings Cutted roof tile Levelling batten Plasma roof tile Plasma eave tile (without ribs on the lower side) C Metalic batten Linkage tile"

Transcription

1 technical drawings Straight bond Cross bond Cutted roof tile Levelling batten 1 Plasma eave tile (without ribs on the lower side) C Metalic batten Linkage tile Omega batten 2

2 Barge tile right Gable left tile Gable right tile Barge tile left 3 Barge right Plasma half tile Plasma half tile Barge left 4

3 487mm Plasma Technical Drawing Detail 251mm 1. Transversal and longitudinal views 2. Isometric view 211mm 385mm 3. Average gauge length 4. Coverage width of 1 Notes: The presented measures are approximate values in mm. Please consult LOHAS technical department to clarify any doubt. We strongly advise not using PVC batten due to its flexibility and way of attachment to the structure (often using nails or bolts with a significant head ) that may interfere with the proper support of the PLASMA tile. It is not advisable to fix using nails, however, opting for this method the tip of the nail should be adapted to prevent cracking or breaking during application.

4 cap and roof tile with opening 250mm 1. Isometric view of roof tile with opening 250mm 2. Isometric view of cap Ventilation duct solution 3. Cross-view 4. Longitudinal cut Ventilation duct Cap for roof tile with opening 250mm Roof tile with opening 250mm Solar tube solution 5. Cross-view 6. Longitudinal cut Roof tile with opening 250mm Solar tube 250mm Acrylic dome Wood batten

5 Chimney Flashing Flashing Flashing Levelling batten Roof tile X = Variable measure depending on the length of the sloping plane and the expected amount of water carried on the flashing. However, this measure should be, at least, 150mm. Elevation Plan view A = It should be created in the casing flange to prevent water from entering the roof. The height of the flange depends on the type of roof structure, and must be at least 20mm (measurement indicative).

6 Chimney support tile 1. Chimney support tile 125mm 2. Isometric view 385mm Chimney cap B (125mm) Chimneu 125 x 200mm Chimney support tile 125mm PLASMA roof tile 3. Longitudinal cut 211mm 4. Cross-section Notes: Chimney support tile 125mm PLASMA is designed for an average slope of 22º(40%). For other inclinations, the combination of the base with the chimney flue must be adjusted on site. The presented measures are approximate values in mm. Please consult LOHAS techinical department to clarify any doubt.

7 collector solar module Horizontal cut Left solar panel gable tile Collector module Tin 80mm 40mm Right solar panel gable tile

8 eave detail with gutter PLASMA roof tile Eave button Gutter X 385mm 385mm X = Variable measure depending on the roof pitch.

9 eave detail PLASMA roof tile Eave button Eave tile 385mm 385mm X S X = Variable measures depending on the roof pitch and measure expected to be projected beyond the wall (S). S = Measure advised to be between 50 e 150mm, for.

10 external facade corner Facade tile Air gap Thermal Insulation External facade corner Rafter Facade tile Air gap Wall Thermal insulation Rafter 1. External facade corner The intersection angle of two vertical planes may not necessarily be 90. These fittings can be adapted to different angles (please consult LOHAS Technical Department). Plasma allows the possibility of simultaneous use on the roof as well as on the facade (there are specific accessories to do this interface). It has two pre-holes so that it can be vertically fixed, with self-drilling screws and washers, our factory also developed an additional metallic clip for using one in each tile of the facade. The use of on the facade, should always implicate the previous evaluation and advising from LOHAS technical department, through the analysis of the architecture project. Facade tile It is not advisable to fix using nails, however, opting for this method the tip of the nail should be adapted to prevent cracking or breaking during application. External facade corner 2. External facade corner - isometric view

11 finishing the corner with Barge Tiles Structure Insolation Facade tile 1. Right corner Rafter Barge tile right Gable tile right Facade tile When applying the barge tile on the corner, the batten should be as much sallent as possible, to allow the fixing of the trim strip to the barge, via a screw, placed on top of the gable or on sideways. Air chamber Facade tile 2. Left corner Barge tile left Gable tile left Eave tile Linkage tile Roof tile Barge tile right Gable tile right Linkage Barge tile right Notes: In areas of high exposure of the roof, the fixing can be achieved by applying screws and washers to pre-existing holes inthe roof tiles. Our factory also developed an additional metallic clip for joint application, using one for each tile on the facade. The application of the on the facade always involves the preliminary assessment and counseling by LOHAS Technical Department, by providing the elements of architectural design. Gable tile right Barge tile right 3. Isometric view of the right corner in the facade

12 finishing the roof edge with/without wall Firewall Flashing Plasma verge tile left Wall X - Variable measure depending on the length of the sloping plane and the expected amount of water carried on the flashing. Wall (S) - and left verge tile lateral overhang, should be between 15 and 20mm creating a drip effect preventing the water flow in the wall. These pieces fixation is made by applying mortar or other similar products of low absorption (eg. FLEXIM). In areas of high exposure of the roof, the fixing can be achieved by the application of screws and washers in the pre-existing holes.

13 finishing the roof edges with Barge Tiles Roof tile Gable left tile Barge tile left Eave tile (without ribs on the lower side) 1. Aligned joint. The roof left edge. Gable right tile Barge tile left Gable left tile Barge tile right 2. Aligned joint. Cross-section. Half tile Roof tile Roof tile Gable right tile Gable left tile Eave tile (without ribs on the lower side) Barge tile right Barge tile left Eave tile (without ribs on the lower side) 3. Aligned joint. 4. Crossed joints. The roof left edge.

14 Plasma half tile 5. Crossed joints. Cross-section Half tile Roof tile Gable right tile Eave tile (without ribs on the lower side) Barge tile right 6. Crossed joints. The roof right edge. 7. Barge tile allowed covering extend. up to Note 1 : The presented measures are approximate values in mm. Note 2 : The average width of 4 is 844mm.

15 imbedded gutter finish detail Lavelling batten Flashing Monopitch roof tile Monopitch roof tile X = Variable measure depending on the length of the sloping plane and the expected amount of water carried on the flashing.

16 internal facade corner Structure / wall Thermal insulation Rafter Internal facade corner Facade tile Air gap 1. Internal facade corner The intersection angle of two vertical planes may not necessarily be 90º. These fittings can be adapted to different angles (please consult LOHAS Technical Department). Structure / wall Thermal insulation Rafter Air gap Internal facade corner Facade tile Plasma allows the possibility of simultaneous use on the roof as well as on the facade (there are specific accessories to do this interface). It has two pre-holes so that it can be vertically fixed, with self-drilling screws and washers, our factory also developed an additional metallic clip for using one in each tile of the facade. The use of on the facade, should always implicate the previous evaluation and advising from LOHAS technical department, through the analysis of the architecture project. It is not advisable to fix using nails, however, opting for this method the tip of the nail should be adapted to prevent cracking or breaking during application. 2. Internal facade corner - isometric view

17 mansard tile detail Convex mansard tile 385mm 385mm 385mm Convex mansard tile 385mm Notes: Pieces available in various angles. The presented measures should be considered approximate. More questions, please contact the LOHAS Technical dept.

18 monopitch roof detail Monopitch roof tile Levelling battens Plasma cut roof tile Plasma facade tile

19 photovoltaic solar module A - Longitudinal cut B - Cross-section Aluminium base module Photovoltaic solar module 1 Photovoltaic solar module 2 1. Plan view (4 PV modules application) Plasma half tile Thermal insulation Photovoltaic module Thermal insulation 2. Isometric view (2 PV modules application) Photovoltaic module 1 Metal clip fixing Photovoltaic module 2

20 ridge tile detail application with mortar Ridge tile Mortar fillet 385mm Plasma cut roof tile 385mm

21 ridge tile detail Dry application Ridge tile Universal ridge holder Wood batten Ridge/hip roll 385mm Plasma cut roof tile 385mm Roll to use on ridges and hips.

22 25mm 90mm Lohas PLASMA Aluminium Profiles Omega aluminium profile Z Aluminium profile Thermal insulation (expanded polystyrene - plates with 1000 x 1000 x 60mm) Omega aluminium profile Plasma facade tile Thermal insulation Wall Fixation point Z aluminium profile Omega aluminium profile Plasma facade tile Plasma facade tile Fixing clip (10mm) Z aluminium profile self-drilling screw 4.8mm x 50mm Thermal insulation Wall sealing washer (16mm) 211mm 1002mm 1002mm 90mm Fixation point

23 RIDGE DETAIL Ridge end cap Gable right tile Gable left tile Barge tile right Barge tile left Ridge end cap Gable right tile Gable left tile Ridge end cap Barge tile left Gable right tile Barge tile right

24 special finishing situations Ridge tile Fillet of mortar 1. Ridge of a mono pitch roof Wall Flashing 2. Emerging wall at the top of the sloping plane Wall Flashing Levelling batten 3. Emerging wall at the bottom of the sloping plane

25 300mm 100mm 100mm valley detail 1. Cross-view 2. Isometric view Plasma cut roof tile Flashing

26 385mm 319mm wall roof linkage Plasma eave tile (without ribs on the lower side) C 385mmX Plasma linkage tile Plasma facade tile Omega X = Variable measures depending on the roof pitch. Notes: Plasma allows the possibility of simultaneous use on the roof as well as on the facade (there are specific accessories to do this interface). It has two pre-holes so that it can be vertically fixed, with self-drilling screws and washers, LOHAS also developed an additional metallic clip for using one in each tile of the facade. The use of on the facade, should always implicate the previous evaluation and advising from LOHAS technical department, through the analysis of the architecture project. It is not advisable to fix using nails, however, opting for this method the tip of the nail should be adapted to prevent cracking or breaking during application.

27 .inf LOHAS AUSTRALIA, AU. All rights reserved. 22a Anzac Street Greenacre 2190 NSw, AUSTRALIA (02) The reproduction of the original colours may not be guaranteed due to print quality. 22A / Anzanc st, greenacre, nsw 2190 tel admin@lohasau.com

roof tiles The safest option Practical and easy to install

roof tiles The safest option Practical and easy to install S-INTERLOCKING roof tiles The safest option Practical and easy to install We offer three formats that combine curved profiles. Thanks to more advanced production processes and the quality of clay used

More information

The IMERYS DOUBLE HP20. CLAY ROOF tile. Large format interlocking clay tiles L5211. (47) Ng2. Project shown: Slate.

The IMERYS DOUBLE HP20. CLAY ROOF tile. Large format interlocking clay tiles L5211. (47) Ng2. Project shown: Slate. The IMERYS DOUBLE HP20 CLAY ROOF tile Large format interlocking clay tiles Uniclass Cl/SfB L5211 (47) Ng2 Project shown: Slate www.imerys-rooftiles.com The IMERYS DOUBLE HP20 CLAY TILE Combining small

More information

PREFA Aluminiumprodukte GmbH Page 1 of 21

PREFA Aluminiumprodukte GmbH Page 1 of 21 Tender Specifications 120901 PREFA Shingles_2012 ---------------------------------------------------------------------------------- 01. Text GENERAL PRELIMINARY REMARKS Roof ----------------------------------------------------------------------------------

More information

IMERYS Environmental Statement

IMERYS Environmental Statement Uniclass IMERYS Environmental Statement L5211 The Imerys Huguenot HP10 Clay Tile Our commitment to sustainable development Cl/SfB (47) Ng2 Large format interlocking clay roof tiles IMERYS has a corporate

More information

IMERYS Environmental Statement

IMERYS Environmental Statement Uniclass IMERYS Environmental Statement L5211 The Imerys Huguenot HP10 Clay Tile Our commitment to sustainable development Cl/SfB (47) Ng2 Large format interlocking clay roof tiles IMERYS has a corporate

More information

The IMERYS BEAUVOISE 20. Clay PLAIN tile. ECONOMICAL interlocking PLAIN tiles L5211. (47) Ng2. Project shown: Burnt Red.

The IMERYS BEAUVOISE 20. Clay PLAIN tile. ECONOMICAL interlocking PLAIN tiles L5211. (47) Ng2. Project shown: Burnt Red. The IMERYS BEAUVOISE 20 Clay PLAIN tile ECONOMICAL interlocking PLAIN tiles Uniclass Cl/SfB L5211 (47) Ng2 Project shown: Burnt Red www.imerys-rooftiles.com The IMERYS Beauvoise 20 Clay PLAIN TILE Economical

More information

Corrugated sheet for single storey, sectional buildings and stables

Corrugated sheet for single storey, sectional buildings and stables Cl/SfB l (4-) Nf9 l l September 2011 l Corrugated sheet for single storey, sectional buildings and stables B5 Corrugated sheet and accessories Cembrit companies have been manufacturing corrugated sheets

More information

Western States 7/8 Corrugated

Western States 7/8 Corrugated Western States 7/8 Corrugated Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer / Installers..1 Fastener Placement and Selection.2-3 Key

More information

Dry Verge Systems. & Roofing Accessories. All your requirements from one source.

Dry Verge Systems. & Roofing Accessories. All your requirements from one source. Dry Verge Systems & Roofing Accessories All your requirements from one source. SLATE DRY VERGE SLATE DRY VERGE TYPE 1 ALUMINIUM TYPE (1) Code: C01 C01N Type: Natural Slate 2mm (C01N) Fibre Cement 18mm

More information

INTRODUCTION. GANG-NAIL Truss System

INTRODUCTION. GANG-NAIL Truss System INTRODUCTION MiTek Australia Ltd revolutionised house construction in Australia when it introduced the use of Gang-Nail multi-tooth connectors for the manufacture of prefabricated timber trusses in the

More information

Topduo Roofing screw. Corrosion protection. Advantages blue+ coating. Advantages Topduo Roofing screw

Topduo Roofing screw. Corrosion protection. Advantages blue+ coating. Advantages Topduo Roofing screw Topduo Roofing screw The wood-construction screw for all over-rafter insulation systems Corrosion protection blue+ is an innovative coating system with greater corrosion resistance than conventional electrogalvanised

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION SECTION 07320 TWO-PIECE TAPERED MISSION CLAY ROOFING TILE PART 1 GENERAL 1.01 SECTION INCLUDES A. Formed clay roofing tiles, complete with components and other required accessories

More information

mounting systems applications overview

mounting systems applications overview mounting systems applications overview catalogue version January 2015 tritec mounting systems: overview of applications i. pitched roof: roof-top 1. Tiles, shingles and corrugated panels 1.1 TRI-STAND

More information

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION Revised September 14 The General Trade Knowledge portion of the examination is administered daily in Computer Based Testing (CBT)

More information

B5 for garages, equestrian and other single storey buildings

B5 for garages, equestrian and other single storey buildings Cl/SfB l (4-) l Nf9 l March 2017 l B5 for garages, equestrian and other single storey buildings Corrugated sheet and accessories www.cembrit.co.uk Cembrit companies have been manufacturing corrugated sheets

More information

Pacific Tile Counter Batten and Batten

Pacific Tile Counter Batten and Batten Pacific Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation

More information

RIB-ROOF System Details. Planning and Building with RIB-ROOF Metal Roofing Systems

RIB-ROOF System Details. Planning and Building with RIB-ROOF Metal Roofing Systems System Details Planning and Building with Metal Roofing Systems Metal Roofing Systems Zambelli A Tradition of Innovation The success of Zambelli had its origins in quality, competence and the spirit of

More information

NEW NEXE ROOF TILES OF LARGE DIMENSIONS, TOP QUALITY, WIDE RANGE OF COLORS AND FORTY YEAR GUARANTEE

NEW NEXE ROOF TILES OF LARGE DIMENSIONS, TOP QUALITY, WIDE RANGE OF COLORS AND FORTY YEAR GUARANTEE an d NEW NEXE ROOF TILES OF LARGE DIMENSIONS, TOP QUALITY, WIDE RANGE OF COLORS AND FORTY YEAR GUARANTEE and roof tiles come in large dimensions and by their quality, color and design they present a unique

More information

PREFA Aluminiumprodukte GmbH Page 1 of 25

PREFA Aluminiumprodukte GmbH Page 1 of 25 Tender Specifications 120901 PREFALZ Double Standing Seam_2012 ---------------------------------------------------------------------------------- 01. Text GENERAL PRELIMINARY REMARKS Roof ----------------------------------------------------------------------------------

More information

J41 Reinforced bitumen membrane roof coverings

J41 Reinforced bitumen membrane roof coverings J41 Reinforced bitumen membrane roof coverings To be read with Preliminaries/General conditions. A comprehensive waterproofing system comprising two reinforced bituminous membranes fully adhered to thermal

More information

ALLMET CONTINENTAL INSTALLATION GUIDE

ALLMET CONTINENTAL INSTALLATION GUIDE ALLMET CONTINENTAL INSTALLATION GUIDE www.allmet.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Allmet Continental

More information

The under-tile thermo insulating system INSTRUCTIONS FOR CORRECT INSTALLATION

The under-tile thermo insulating system INSTRUCTIONS FOR CORRECT INSTALLATION The under-tile thermo insulating system INSTRUCTIONS FOR CORRECT INSTALLATION The under-tile thermo insulating system PHASE 1 STARTING INSTALLATION Pag. 3 NOTE CUTTING THE PANEL Pag. 4 PHASE 2 JOINTS AND

More information

INSTALLATION GUIDE.

INSTALLATION GUIDE. INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Gerard Canyon Shake counter batten

More information

Contents DESIGNER S STRUCTURAL PRODUCTS GUIDE. Tegral Purlins & Rails

Contents DESIGNER S STRUCTURAL PRODUCTS GUIDE. Tegral Purlins & Rails DESIGNER S STRUCTURAL PRODUCTS GUIDE Introduction Contents Tegral Purlins & Rails Zeta Purlins & Rails Zeta Purlins page 8 Zeta Rails page 15 Zeta Purlin & Rail Cleats page 22 Zeta 2 Purlins & Rails Zeta

More information

PIPE. Central Texas Largest Distributor. Structural Steel, Pipe and Metal Building Components

PIPE. Central Texas Largest Distributor.  Structural Steel, Pipe and Metal Building Components Central Texas Largest Distributor Structural Steel, Pipe and Metal Building Components PIPE Waco Location P.O. Box 154485 913 South Loop Dr. Waco Texas 76705 Local - 254-754-2611 Bryan Location 9401 E.

More information

Central Snap. Condition Details C SNAPDETAILS

Central Snap. Condition Details C SNAPDETAILS Central Snap Condition Details D C SNAPDETAILS150612.2 The men and women at Central States Manufacturing, Inc. would like to welcome you. OUR MISSION Central States Manufacturing, Inc. is a 100% employee-owned

More information

Hip Detail. Construction Details. KS1000 LP/CR Roof. Hip Detail STANDARD ENHANCED ENHANCED STANDARD. Mineral fibre insulation

Hip Detail. Construction Details. KS1000 LP/CR Roof. Hip Detail STANDARD ENHANCED ENHANCED STANDARD. Mineral fibre insulation Hip Detail Hip Detail STANDARD Mineral fibre insulation ENHANCED Hip flashing with 150mm sealed butt straps Panels site cut to suit rake angle Apex dam (Ref: LP1/A) Rake cut profiled filler sealed top

More information

Chapter 7. Roof Framing

Chapter 7. Roof Framing Chapter 7. Roof Framing 7.1 ROOFING PREP WORK 7.2 INSTALLING ROOF TRUSSES 7.3 INSTALLING PORCH TRUSSES 7.4 SHEATHING ROOF 7.5 INSTALLING SUB-FASCIA 7.6 BUILDING AND INSTALLING SCUTTLE BOX 7.7 INSTALLING

More information

GRP Flat Roofing Edge Trims

GRP Flat Roofing Edge Trims GRP Flat Roofing Edge Trims Compatible with GRP, rigid and flexible polyester, polyurethane, acrylic and alkyd systems. Trim Brochure and Technical Specification Guide General Information The Easy To Use

More information

DAN S CUSTOM SHEETMETAL Manufacturer and Distributor

DAN S CUSTOM SHEETMETAL Manufacturer and Distributor About the Company DAN S CUSTOM SHEETMETAL Manufacturer and Distributor In 1993, DCSM was the first manufacture in the state of Florida to fabricate metal eave closure for tile. We have established a reputation

More information

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION MANUFACTURED ROOF EXPANSION JOINTS SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

DRAWING INDEX Description

DRAWING INDEX Description DRAWING INDEX Qty. Description TOOL LIST PAGE #1 PANEL & PANEL RACK HANDLING TIPS 2 BASIC BUILDING COMPONENTS 3 ELEVATIONS 4 MATERIALS LIST 5 BUILDING LAYFLAT 6 FOUNDATION PREPARATION PLAN VIEW 7 BASE

More information

Industry Standard Terms & Definitions Of The Steel Deck Institute

Industry Standard Terms & Definitions Of The Steel Deck Institute Industry Standard Terms & Definitions Of The Steel Deck Institute A specialized set of jargon to describe common terms used by manufacturers and other professionals associated with the usage of Steel Deck

More information

NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS

NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS Nucor VR16 II Vertical Rib Standing Seam Roof System...2 Nucor VR16 II Property and Span Tables...3 Standard Details...5 ED3010PE - Gutter...5

More information

The IMERYS. CLAY PLAIN tile. Huguenot 20x30. Combining economy with fine clays L5211. (47) Ng2. Project shown: Alezanne.

The IMERYS. CLAY PLAIN tile. Huguenot 20x30. Combining economy with fine clays L5211. (47) Ng2. Project shown: Alezanne. The IMERYS Huguenot 20x30 CLAY PLAIN tile Combining economy with fine clays Uniclass Cl/SfB L5211 (47) Ng2 Project shown: Alezanne www.imerys-rooftiles.com The IMERYS Huguenot 20x30 CLAY PLAIN TILE The

More information

Planning and installation instructions

Planning and installation instructions Planning and installation instructions Stofix Oy Ahlmaninkatu 2 E 40100 Jyväskylä Finland stofixgroup@stofix.com www.stofix.com 2 PLANNING AND INSTALLATION INSTRUCTIONS... 1 1 General... 3 2 Project Design...

More information

Insulating systems used in agricultural and industrial buildings

Insulating systems used in agricultural and industrial buildings Insulating systems used in agricultural and industrial buildings INTRODUCTION Since years, RECTICEL is a leading manufacturer of systems for internal insulation. The EUROTHANE product range has been especially

More information

Sub-construction for Wall-mounted Longlight

Sub-construction for Wall-mounted Longlight modular skylights Sub-construction for Wall-mounted Longlight Subconstruction for Wall-mounted Longlight at 5-40 pitch modular skylights in a wall-mounted longlight solution, can be installed on a sub-construction

More information

The Imerys Phalempin Clay Plain Tile

The Imerys Phalempin Clay Plain Tile The Imerys Phalempin Clay Plain Tile Continuing a tradition of excellence in clay plain tiles Phalempin Weathered Project by Hallmark Developments Innovation for Sustainable Homes The Phalempin 17x27 Clay

More information

Clenergy ezrack SolarRoof Code-Compliant Planning and Installation With Australia AS/NZS1170

Clenergy ezrack SolarRoof Code-Compliant Planning and Installation With Australia AS/NZS1170 Clenergy ezrack SolarRoof Code-Compliant Planning and Installation With Australia AS/NZS1170 The ezrack has been developed as a universal system for roof-mounting on pitched roofs. The use of patented

More information

OREGON ROOF CONSULTING - ROOF INSPECTION FORM

OREGON ROOF CONSULTING - ROOF INSPECTION FORM Oregon CCB: 199121 PO Box 220190, Milwaukie, OR 97222 Washington License: OREGORC871MR OREGON ROOF CONSULTING - ROOF INSPECTION FORM General Roof Conditions: NA = Not Applicable Debris on Roof Physical

More information

Standing Seam Systems. NBS Specification. KingZip SF Standing Seam Roofing System

Standing Seam Systems. NBS Specification. KingZip SF Standing Seam Roofing System NBS Specification KingZip SF Standing Seam Roofing System H31 METAL PROFILED/FLAT SHEET CLADDING/COVERING To be read with Preliminaries/General conditions. TYPE OF CLADDING SYSTEM 140 METAL PROFILED CLADDING

More information

RIB-ROOF System Details. Planning and Building with RIB-ROOF Metal Roofing Systems

RIB-ROOF System Details. Planning and Building with RIB-ROOF Metal Roofing Systems System Details Planning and Building with Metal Roofing Systems Metal Roofing Systems Zambelli A Tradition of Innovation The success of Zambelli had its origins in quality, competence and the spirit of

More information

MOUNTING SYSTEM FOR PITCHED ROOF WITH TILES. mounting system for pitched roof with tiles for solar panels in landscape setup. Rev

MOUNTING SYSTEM FOR PITCHED ROOF WITH TILES. mounting system for pitched roof with tiles for solar panels in landscape setup. Rev MANUAL EN MOUNTING SYSTEM FOR PITCHED ROOF WITH TILES mounting system for pitched roof with tiles for solar panels in landscape setup ESDEC BV 2016 TABLE OF CONTENT 1. Introduction 1 2. General installation

More information

SLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017]

SLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017] [Change these specifications as needed. Use this sample proposal at your own risk. This is a simple, general proposal and is not meant to be a comprehensive proposal for all situations or projects. If

More information

Terracotta Roofing Book

Terracotta Roofing Book 5 EDITION Terracotta Roofing Book PLAIN TILES INTERLOCKING TILES BARREL TILES MEDITERRANEAN TILES OUTSTANDING TILES LAMBERT TBF GUIRAUD Please Note: The minimum-pitch and ventilation recommendations of

More information

J41 Reinforced bitumen membrane roof coverings

J41 Reinforced bitumen membrane roof coverings J41 Reinforced bitumen membrane roof coverings To be read with Preliminaries/General conditions. TYPES OF COVERING 110 BUILT-UP REINFORCED BITUMEN MEMBRANE WARM DECK ROOF COVERING Substrate: Plywood to

More information

SECTION ROOF SPECIALTIES

SECTION ROOF SPECIALTIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

Installer Guide. Item

Installer Guide. Item Installer Guide Item 17392-01 Required tools and fixings Electric drill (non-impact setting) T-30 Torq bit (wedge type) 8mm hex socket Pozi head drill bit Tape measure Pencil/pen Hammer Tin snips Angle

More information

PROTEKTOR PROFILES FOR EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS

PROTEKTOR PROFILES FOR EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS PROTEKTOR PROFILES FOR EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS 2 1 2 1 210 212 21 211 212 211 212 21 21 2 22 0 0 0 0 0 21 2 00 01 02 00 01 02 0 0 12 1 1 1 1 1 1 12 11 11 12 12 12 1 1 1 1 11 2 0 1

More information

June GANG-NAIL ROOF TRUSS SYSTEM (incorporating Attic Trusses) Residential Manual

June GANG-NAIL ROOF TRUSS SYSTEM (incorporating Attic Trusses) Residential Manual une 2008 GANG-NAIL ROOF TRUSS SYSTEM (incorporating Attic Trusses) Residential Manual GANG-NAIL Roof Truss Systems are available only through GANG-NAIL Fabricators throughout New Zealand Refer to the MiTek

More information

Onduline Oversheeting Benefits. Onduline Sheet Specification. Insulation. The Onduline colour range

Onduline Oversheeting Benefits. Onduline Sheet Specification. Insulation. The Onduline colour range Onduline Oversheeting Benefits Low cost. The Onduline colour range Reduced health risk in handling and disposing of existing hazardous roof coverings. Virtually maintenance-free. Improved thermal and sound

More information

COMP ONENT CATA LO GUE FOR INDUSTRIAL BUILDINGS

COMP ONENT CATA LO GUE FOR INDUSTRIAL BUILDINGS M a d e f o r b u i l d i n g b u i l t f o r l i v i n g COMP ONENT CATA LO GUE FOR INDUSTRIAL BUILDINGS I M P R i n t KLH Massivholz GmbH Publisher and responsible for the content: KLH Massivholz GmbH

More information

D Side lap. Side lap screw spacing < 500mm factory-installed seals on side lap. Decoupling tape > 60mm

D Side lap. Side lap screw spacing < 500mm factory-installed seals on side lap. Decoupling tape > 60mm 25 Side lap screw spacing < 500mm 333.3 15 42 Decoupling tape > 60mm 3 factory-installed seals on side lap Side lap D 201.1 SECTION VIEWS Type L Ridge profile Type R Ridge flashing FLOOR PLAN > 200 overlap

More information

PROFILE S6 CORRUGATED SHEETS

PROFILE S6 CORRUGATED SHEETS PROFILE S6 CORRUGATED SHEETS CONTENT 02 04 06 The ideal corrugated sheet exists Why choose PROFILE S6 corrugated sheets Colours 07 Range 08 Accessories 10 Pre-grooved/ mitred corners The ideal corrugated

More information

Sub-construction for longlight

Sub-construction for longlight modular skylights Sub-construction for longlight Sub-construction for longlight at 5-25 pitch modular skylights installed in a longlight solution are build on a sub-construction made of wood, steel or

More information

NU-WALL EXTRUDED ALUMINIUM CLADDING. Installation Specifications Vertical orientation (over cavity)

NU-WALL EXTRUDED ALUMINIUM CLADDING. Installation Specifications Vertical orientation (over cavity) September 2014 NU-WALL EXTRUDED ALUMINIUM CLADDING Installation Specifications Vertical orientation (over cavity) 1. NW-V001C; Cavity batten layout 2. NW-V002C; Battening options 3. NW-V002C; Battening

More information

ICC-ES Report OR-4, AND MOISTURE DIVISION: SECTION: SECTION: Reissued 11/2017 This. Report Holder:

ICC-ES Report OR-4, AND MOISTURE DIVISION: SECTION: SECTION: Reissued 11/2017 This. Report Holder: ICC-ES Report ESR-3482 Reissued 11/2017 This report is subject to renewal 11/2018. EVALUATION SUBJECT: LO-OMNIROLL LOR-30, LO-OMNIRIDGE LOR9-4, OMNIRIDGE OR-4, TILERIDGE TRV-4, TILEINTAKE IV-9 AND DECK-AIR

More information

INSTALLATION MANUAL Heritage Series

INSTALLATION MANUAL Heritage Series INSTALLATION MANUAL Heritage Series STEEL ROOF PANELS HEAD OFFICE 1418 Michael St., Ottawa, ON K1B 3R2 WATS LINE: 1 800-267-0860 TEL.: 1 613-746-3206 FAX: 1 613-746-0445 Contents Page Introduction, Storage..

More information

SolarStyl BIPV New Building Integrated Photovoltaic System August V13 Page 0

SolarStyl BIPV New Building Integrated Photovoltaic System August V13 Page 0 SolarStyl BIPV New Building Integrated Photovoltaic System 2010 August V13 Page 0 By ArcelorMittal Stainless & Nickel Alloys SolarStyl Frame for BIPV Systems To simplify photovoltaic roof and facade design.

More information

CURVED Mission Barrel

CURVED Mission Barrel CURVED Mission Barrel PAJA T4 / T5 FLAMED PAJA T4 / T5 CURVED MISSION BARREL Renewal of a beautiful tradition Traditionally, this 2 piece tile, also referred to as Mission barrel, has been the most frequently

More information

Central Texas Metal Roofing Supply Co., Inc 36" NET COVERAGE SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 40 ¼ 40 ¼

Central Texas Metal Roofing Supply Co., Inc 36 NET COVERAGE SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 40 ¼ 40 ¼ 36" 1 2 " 6" GAUGE PANEL FINISH NET COVERAGE SHEET WIDTH WEIGHT PER SQ. 26 26 26 26 24 24 24 24 TEXAS RIB CHANNEL GUARD TEXAS RIB CHANNEL GUARD TEXAS RIB CHANNEL GUARD CHANNEL GUARD CHANNEL GUARD GALVALUME

More information

City of Republic Community Development Department. Residential Roofs REVISION DATE: JANUARY 2017

City of Republic Community Development Department. Residential Roofs REVISION DATE: JANUARY 2017 City of Republic Community Development Department Residential Roofs REVISION DATE: JANUARY 2017 A residential roof permit is required for new roofs and for replacement roofs when the replacement area is

More information

CI/SfB (47) Ng2 July Neo Pantile New generation clay pantile

CI/SfB (47) Ng2 July Neo Pantile New generation clay pantile CI/SfB (47) Ng2 July 2006 Neo Pantile New generation clay pantile Neo Pantile The Neo Pantile is the first of a new generation of open gauge interlocking clay tiles that have been designed by Sandtoft

More information

TRIAD CORRUGATED METAL, INC.

TRIAD CORRUGATED METAL, INC. TRIAD CORRUGATED METAL, INC. C O M M E R C I A L R E S I D E N T I A L A G R I C U L T U R A L Snap Loc Panel Guide Snap Loc metal panels are a perfect fit for residential, architectural and commercial

More information

Hoesch isodach integral Technical information

Hoesch isodach integral Technical information Technical information A company of ThyssenKrupp Steel tk Contents Page General 3 Main dimensions and properties 4 Corrosion protection 5 Thermal protection / Insulating core 5 Fire protection 5 Information

More information

RS32 Multi-Section Skylight System under/over seam clip double diverter

RS32 Multi-Section Skylight System under/over seam clip double diverter INSTALLATION INSTRUCTIONS RS32-x RS32 Multi-Section Skylight System under/over seam clip double diverter www.rnssales.com sales@rnssales.com 805.375.3980 Fax 805.375.3981 SKYLIGHT ACRYLIC skyline series

More information

Design Manual Facade, riveted Panel fixed to T-Sections

Design Manual Facade, riveted Panel fixed to T-Sections Design Manual Facade, riveted Part Product changes in the sense of a technical progress are reserved. All advice recommendation and information is given to the best of our knowledge but without any obligation

More information

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590

More information

CI/SfB (47) Uniclass Pr_25_93_72 January ROOFING ACCESSORIES ...

CI/SfB (47) Uniclass Pr_25_93_72 January ROOFING ACCESSORIES ... ........................................... CI/SfB (47) Uniclass Pr_25_93_72 January 2018 ................................. PROTECT SOLUTIONS Protect accessories for tile and slate roofs provide a range

More information

PRE-ENGINEERED METAL BUILDING SYSTEM

PRE-ENGINEERED METAL BUILDING SYSTEM PRE-ENGINEERED METAL BUILDING SYSTEM PART 1 GENERAL 1.1 SUMMARY A. The building shall include all primary and secondary structural framing members, connection bolts, roof and wall covering, flashing, gutter,

More information

BENCHMARK Evolution Axis

BENCHMARK Evolution Axis Sheet List EVO VT 00 B DIRECTION OF PREVAILING WIND VERTICAL PANEL JOINT & FASTENER LOCATIONS DIRECTION OF LAY FACTORY APPLIED WEATHER SEAL CONCEALED PANEL FIXING NOTE: FASTENER NUMBERS DEPEND ON THE ACTUAL

More information

INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK

INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK A. 1. Using curb ribs as a guide, layout and mark roof openings on completed roof deck as outside curb

More information

Ability Building Services Bill of Quantities

Ability Building Services Bill of Quantities Page 1 of 6 0001 General Notes 0001-0100 EUROPEAN HOUSE BORER 0 1 1 ************************************************************************* The Department of Housing & Works recommends that in areas

More information

Brava Spanish Tile. Installation Manual. Brava Roof Tile Phone: Fax:

Brava Spanish Tile. Installation Manual. Brava Roof Tile Phone: Fax: Brava Spanish Tile Installation Manual Brava Roof Tile Phone: 319-338-5706 Fax: 319-343-1038 www.bravarooftile.com This document includes the recommended and suggested installation procedures for Brava

More information

CASSETTE SP Implementation guide

CASSETTE SP Implementation guide CASSETTE SP Implementation guide Published on 21 August 2007 PMA by Arval ZA du Pays de Podensac 33720 CERONS - France Tel. +33 (0)5.57.98.14.50 Fax. +33 (0)5.57.98.14.60 commercial@pma.fr www.pma.fr PRESENTATION

More information

PITCHED ROOF. Photovoltaic Mounting Systems. Assembly Instructions. for roofing tiles, plain tiles and slate

PITCHED ROOF. Photovoltaic Mounting Systems. Assembly Instructions. for roofing tiles, plain tiles and slate Photovoltaic Mounting Systems Assembly Instructions PITCHED ROOF for roofing tiles, plain tiles and slate S:FLEX GmbH 09/2017 / design and engineering is subject to change 1 Index 1 Introduction 1.1 Intended

More information

PRODUCT CONTROL SECTION

PRODUCT CONTROL SECTION MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590

More information

1 Exam Prep Roofing Practice Exam 12

1 Exam Prep Roofing Practice Exam 12 1 Exam Prep Roofing Practice Exam 12 1. ccording to the NR, when applying double-layer underlayment to the substrate, the drip-edge metal should be Sandwiched between the layers Placed below the felt along

More information

Renovation of Buildings using Steel Technologies (ROBUST)

Renovation of Buildings using Steel Technologies (ROBUST) Renovation of Buildings using Steel Technologies (ROBUST) RFCS Project RFSR-CT-2007-0043 WP 4.2 Renovation of roofs using open trusses in light steel C sections Date: 2009 Author: Mark Lawson SCI, Silwood

More information

Siding and Soffit Installation Guidelines

Siding and Soffit Installation Guidelines Siding and Soffit Installation Guidelines email web phone 07 46 16 Longboard Siding & Soffit INTRODUCTION INSTALLATION GUIDELINES NOTE: These instructions are prepared for persons experienced in the field

More information

Scope. Definitions. For definitions of terms used in this application standard, refer to ASTM 1079 and the Florida Building Code, Building.

Scope. Definitions. For definitions of terms used in this application standard, refer to ASTM 1079 and the Florida Building Code, Building. ROOFING APPLICATION STANDARD (RAS) No. 119 INSTALLATION OF MECHANICALLY FASTENED ROOF TILE SYSTEMS Direct Deck & Horizontal Battens Only (Preformed Metals With Edge Returns) 1. Scope This application standard

More information

CI/SfB (47) Uniclass L529 July ROOFING ACCESSORIES ...

CI/SfB (47) Uniclass L529 July ROOFING ACCESSORIES ... ........................................ CI/SfB (47) Uniclass L529 July 2014............... ................................ ROOFING............. ACCESSORIES. GLIDEVALE SOLUTIONS Glidevale accessories

More information

Central Texas Metal Roofing Supply Co., Inc NET COVERAGE SHEET WIDTH

Central Texas Metal Roofing Supply Co., Inc NET COVERAGE SHEET WIDTH 1 2 " 1 24" GAUGE PANEL FINISH NET COVERAGE SHEET WIDTH WEIGHT PER SQ. 26 5 Vee GALVALUME 24 26 3/8 95.00 PRICE PER SQ. PRICE PER LINEAR FOOT PANEL PRICING: 1. Price per Square is based on 26 3/8 sheet

More information

THE GUIDE TO GOOD LEADWORK. Nobody knows more about lead than Calder!

THE GUIDE TO GOOD LEADWORK. Nobody knows more about lead than Calder! THE GUIDE TO GOOD LEADWORK This booklet has been produced to promote and encourage the correct use of lead sheet flashings, weatherings and gutter linings in building. Nobody knows more about lead than

More information

INSTALLATION INSTRUCTIONS ENGLISH

INSTALLATION INSTRUCTIONS ENGLISH INSTALLATION INSTRUCTIONS ENGLISH Safety instructions 04 General notes 07 Material & tool requirements 08 System overview 10 installation of ALUTEC 12 Maintenance 27 04 INTENDED USE Creotecc mounting

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FACED PANELS REPORT HOLDER: MEXALIT INDUSTRIAL, S.A. DE C.V.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FACED PANELS REPORT HOLDER: MEXALIT INDUSTRIAL, S.A. DE C.V. 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2058 Reissued 06/2017 This report is subject to renewal 06/2018. DIVISION: 07 00 00 THERMAL

More information

City of Santa Monica Building and Safety Division Submittal Requirements Expedited Solar Photovoltaic (10 kw or Less)

City of Santa Monica Building and Safety Division Submittal Requirements Expedited Solar Photovoltaic (10 kw or Less) City of Santa Monica Building and Safety Division Submittal Requirements Expedited Solar Photovoltaic (10 kw or Less) Permits for One- and Two-Family Dwellings This following information is to guide applicants

More information

KS SERIES - VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV

More information

SOLAR-LINE. Roofing accessories for solar systems. Providing expertise in the installation of photovoltaic and solar thermal systems

SOLAR-LINE. Roofing accessories for solar systems. Providing expertise in the installation of photovoltaic and solar thermal systems SOLAR-LINE Roofing accessories for solar systems Providing expertise in the installation of photovoltaic and solar thermal systems Expertise in solar energy systems Klober s expertise can play an important

More information

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge Assembly Manual 8x9 PATENTS ARE PENDING Approximate Size 7640303 Storage Area Building Dimensions Exterior Dimensions Roof Edge to Roof Edge Interior Dimensions Wall to Wall Sq. Ft. Cu. Ft. Width Depth

More information

CASSETTE BS Specification book

CASSETTE BS Specification book CASSETTE BS Specification book Edition: April 2011 ArcelorMittal Construction International Industriestrasse 19 8112 Otelfingen / Zürich Switzerland www.arcelormittal.com/arval PRESENTATION OF THE SYSTEM

More information

SECTION PRE-ENGINEERED BUILDING INSULATION

SECTION PRE-ENGINEERED BUILDING INSULATION PART 1 GENERAL SECTION 07213 PRE-ENGINEERED BUILDING INSULATION Microsoft Word Instructions: Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text". 1.1 SECTION INCLUDES A. Pre-Engineered

More information

Mounting instructions. novotegra for trapezoidal metal - roof parallel

Mounting instructions. novotegra for trapezoidal metal - roof parallel Mounting instructions novotegra for trapezoidal metal - roof parallel I TABLE OF CONTENTS 1 Notes... 1 2 Maintenance of the mounting system... 3 3 novotegra for trapezoidal metal - roof parallel... 3 4

More information

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 NOTICE OF ACCEPTANCE

More information

HOW TO FIGURE METAL ROOFING MATERIALS

HOW TO FIGURE METAL ROOFING MATERIALS HOW TO FIGURE METAL ROOFING MATERIALS 1. The first step in figuring your metal roofing is to make a sketch of it, complete with the roof measurements. Take the house below as an example: 52 R 12-8 P 19

More information

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The Ashland Project Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The garage and bedroom extend from the front of this three bedroom home, drawing you visually into the entryway. Brick and stucco

More information

S BI COM P ON E NT CA T ALOG

S BI COM P ON E NT CA T ALOG SBI METAL BUILDINGS & COMPONENTS S BI COM P ON E NT CA T ALOG Date: 03 / 16 / 2017 COMMERCIAL PRODUCTS Commercial Panels and Trim Cee, Zee, Eave Struts, Angle, Channel, and Clips Accessories FT 0 1 2 3

More information

Cl/SfB (47) Nf9 February Roof Slate. Jutland. fibre cement slate with straight edge and smooth surface. Year guarantee

Cl/SfB (47) Nf9 February Roof Slate. Jutland. fibre cement slate with straight edge and smooth surface. Year guarantee Cl/SfB (47) Nf9 February 2018 Roof Slate Jutland fibre cement slate with straight edge and smooth surface Year guarantee Jutland slate Cembrit manufacturing plants have been developing and supplying roofing

More information

Complete Cupola Units

Complete Cupola Units Table of Contents Steeples...3-10 Steeple & Cupola Accessories...11 Cupola...12-14 Lighthouse...15 Domes...16 Finials...17 Steeple & Cupola Installation Guidelines...18-19 Baptistries...20-24 Baptistry

More information