2 important notice This manual contains suggestions and guidelines on how to install the subject Quality Metals time without incurring any obligations. To insure you have the latest information available, please inquire or visit our website. Application and design details are for illustrative purposes only and may not be appropriate for all environmental conditions and/or building designs. Projects should be engineered and installed to conform to applicable building codes, regulations, and accepted industry practices.
3 Introduction ML-150 is a non-structural panel which is mechanically seamed during installation. The product is an integral interlocking system by design meaning the panels install in one direction from a given starting point. with a wide range of building designs. Two clips are center point allowing for multi-directional expansion. Factory Apply Sealant available. Applications fascia, equipment screens, mansards, and wall panels. This system may also be installed on tapered and curved roof areas. other applications. Design ML-150 Standing Seam requires low maintenance. The panel is secured with concealed clips and the panel side laps are locked together using a rooftop seaming machine. Testing UL 790 Fire Test of Roof Coverings, Class A, B, C UL 2218 For Impact Resistance, Class 4 UL 580 Uplift Resistance. Class 90 Construction No INSTALLATION Solid Substrate Required Snap Seam No Field Seaming Required Weather Tight Warranty is not Available Underlayment Required Oil Canning reduce the incidence of oil canning in the panels. Installer must have prior experience and knowledge of the tolls listed below and their uses in working with Specifications Color and Finishes 24 and 26 Gauge Galvalume 35 Year Finish Warranty on Kynar 500 Finish Widths Actual Panel Coverage (Width): Max 16 Minimum Slope = ½:12" Lengths ML-150 Panel is available in standard lengths from 4 to 40. Longer lengths require additional handling, packaging, and shipping considerations. An extra handling charge may apply to panels over 40. Continuous Rollformed Lengths: eliminates need for panel lap joints. Caulking Gun Snips Cordless Screw Gun Pop Rivet Tool Tape Measure Hemming Tool Electrical Extension Cord Heavy Gloves Safety Glasses
4 Packaging Options Standard packing A packaging charge will be added to all orders. Standard packing is crating for all orders. Storage Bare Galvalume and painted panels can be expected to give many years of rust-free service when precautions are taken during storage. If metal is not to be used immediately, store inside in a well ventilated, dry location. Any outdoor storage is at the customer s own risk! At time of delivery, inspect panels for moisture. If moisture has formed, the panels should be uncrated, wiped dry, and allowed to dry completely. Failure to remove the entrapped moisture between the sheets immedi- Extended storage of panels in a bundle is not recommended. Storage on Roof, Crates need to be placed parallel to the framing members and the slope of the roof. LTL packing For LTL, panels are packaged in a completely enclose crate to provide optimum protection. Additional charges will apply for non-standard packing and special requests. Strippable film Removal applied to the topside of the panel to prevent possible damage to the painted surface. If panel has a protective sunlight and high temperatures. remain on the panels after installation. Lead Time Please allow 2-3 days for delivery for material or colors we have in stock. Color we have to paint please allow working days. Receiving Materials It is the responsibility of the installer to unload material from the delivery truck. The installer shall be responsible for providing suitable equipment for unloading of material from the delivery truck. After receiving material, check the condition of the material, and review the shipment against the shipping list to ensure all materials are accounted for. If damages or shortages are discovered, it should be noted on the shipping copy at time of delivery. If material is delivered by common carrier, a claim must be made with the carrier as soon as possible
5 Packaging Options Standard packing A packaging charge will be added to all orders. Standard packing is crating for all orders. Storage Bare Galvalume and painted panels can be expected to give many years of rust-free service when precautions are taken during storage. If metal is not to be used immediately, store inside in a well ventilated, dry location. Any outdoor storage is at the customer s own risk! At time of delivery, inspect panels for moisture. If moisture has formed, the panels should be uncrated, wiped dry, and allowed to dry completely. Failure to remove the entrapped moisture between the sheets immedi- Extended storage of panels in a bundle is not recommended. Storage on Roof, Crates need to be placed parallel to the framing members and the slope of the roof. LTL packing For LTL, panels are packaged in a completely enclose crate to provide optimum protection. Additional charges will apply for non-standard packing and special requests. Strippable film Removal applied to the topside of the panel to prevent possible damage to the painted surface. If panel has a protective sunlight and high temperatures. remain on the panels after installation. Lead Time Please allow 2-3 days for delivery for material or colors we have in stock. Color we have to paint please allow working days. Receiving Materials It is the responsibility of the installer to unload material from the delivery truck. The installer shall be responsible for providing suitable equipment for unloading of material from the delivery truck. After receiving material, check the condition of the material, and review the shipment against the shipping list to ensure all materials are accounted for. If damages or shortages are discovered, it should be noted on the shipping copy at time of delivery. If material is delivered by common carrier, a claim must be made with the carrier as soon as possible
6 mechanical handling: Forklift A forklift may be used for panels up to 20 long. Please make sure the forks are at their maximum separation. Do nor transport open crates. When transporting crates across rough terrain, or for a long distance, some means of supporting the panel load must be used. Improper loading and unloading of crates may result in bodily harm and /or material damage. Union Corrugating is not responsible for bodily injuries and/or material damages resulting from impoper loading and unloading. general handling Each crate should be handled carefully to avoid being damaged. Care should be taken to prevent bending of for proper care while unloading and handling crates in order to prevent panel damage: 1. Crates should remain intact during any handling, and until the individual panels in each bundle are ready to be installed. Crates should never be lifted by the banding. 2. Lift each crate as close as possible to its center of gravity. crane A crane should be used when lifting panels with lengths greater than 20. please be sure to utilize a spreader bar to ensure the even distribution of the weight to the pick up points. As a rule, when lifting panels, no more than 1/3 of the length of the panel should be left unsupported. Canvas or nylon slings should be used to pick up the panels. DO NOT use cable or chains because this will damage the panels. 3. If the crates are to be lifted with a crane, use a spreader bar of appropriate length, and nylon band slings. (Do not use wire rope slings as they will damage the panels). 4. Depending on panel length, some crates may be lifted by a forklift. When using a forklift, the forks should be spread apart to their maximum spacing, and the load must be centered on the forks to prevent scratching the next panel. A panel should never be picked up by it s ends. Instead, lift the panel along its longitudinal panels over 10 feet long, two or more people should lift the panel along the same edge. 5. After creates are opened, individual panels must also be handled carefully to prevent panel buckling or damage to the panel coating. When removing a panel from a crate, it should never be allowed to slide over another panel. The individual panels should be rolled out of the crate in order to minimize the chance of panel damage
7 manual handling: 6. Soft gloves must be worn when handling panels. A panel should never be picked up by its ends. Instead, lift the panel along its longitudinal edge and carry in a All applicable safety regulations, including OSHA regulations, must be complied with during the panel installation process. FOOT TRAFFIC: 6-8 MAX necessary for maintenance over certain areas of the roof, then a permanent walkaway should be installed. field cutting The snips or a nibbler type electric tool are recom- Mechanical Lock panels. If a skill saw is used, the blade will generate silvers of metal chips. Any silvers of metal chips must be immediately removed from the Mechanical Lock panels because product. panels over when cutting. This allows the silvers of metal chips to be brushed from the back side and avoids damaging the paint on the top side of the panels. - tion, provide walking platforms to avoid any panel damage as shown below. Walking on the ribs can cause damage of the panels. Walking Platforms All product surfaces should be free of debris at all times. Installed surfaces should be wiped clean at the end of each work period. Never cut panels over metal surfaces. Metal shavings will rust on the surface thus voiding the warranty. Quality Metals Panels Foot Traffic When cutting metal panels, goggles must be worn for eye protection Quality Metals Panels
8 design considerations & calculations Proper design and installation of vapor barriers and ventilation systems are important to prevent condesation and the resulting problems of moisture damage an Vent Attic Insulation Concensation occurs when moisture-laden air comes in contact with a surface temperature equal to or below the dew point of the air. This phenomenon creates problems that are not unique with metal buildings; these problems are common to all types of construction. In addition to providing resistance to heat transfer, insulation can also protect against condensation forming on cold surfaces, either inside the building or within the wall/roof system cavity. The arrangement of the building s insulation system and vapor retarder is the responsibility of the building designer. These are some basic guidelines to help contro condensation in a metal building: 1. The insulation should have a vapor retarder face on the warm side of the insulation. For most buildings, this means that the vapor retarder is on the side surface. (toward the building s interior) 2. The thickness of the insulation must be designed to maintain the temperature of the vapor retarder above the interior dew point, using the worst-case expected outside temperature. 3. All perimeter conditions, seams, and penetrations of the vapor retarder must be adequately sealed in order to provide a continuous membrane to resist the passage of water vapor. Touch Up Paint: Vent at Eave result in some small scratches or nicks to the paint Touch-up paint is available in matching colors. It is recommended that a small brush be used to apply touch-up paint to those areas that are in need of repair. Touch-up paint does not have the superior chalk and will normally discolor at an accelerated rate. Periodic touch-up may be required to maintain color match. There is no warranty on touch-up paint in regards to color match because the paint processes are Aerosol paint should not be used because of the overspray that may occur. 4. Building ventilation, wheter by gravity ridge vent, power operated fans, or other means, contributes, signifacly to reduce condensation. The movement of air to the outside of the building reduces the interior level of vapor pressure. On buildings that have an attic space or are being retroplaced at both ends of the eave and peak of the roof in order to prevent a buildup of moisture (humidity) in the attic space. Touch-Up Paint Small Brush
9 accesories ¼ 14 x 7/8 Hex Head Lap Tek Screw metal to metal #10 x 1-½ Hex Head Woodmate Screw Metal-to-Wood #10 x 1 Pancake Head Woodscrew 2 Pancake Head Woodgrip 1-½" 1-½" 36" 1-3/4" 1 Pancake Head Tek Screw 2-½ Pancake Head Tek Screw Neoprene Universal Closure Vented Ridge Closure Closure Tube Sealant Hand Crimper Double Bead Butyl Tape (7/8 x 3/16 x 40 ) Pipe Boot (Various sized, heat treated Clips Roll Valley 20 x 50 Hemming Tool Bearing Plate
10 fastener installation recomended toll type Use depth locating nose or adjustable clutch on screw gun to prevent over-drilling and strip out. Do not use impact tools or runners. washer. DO NOT OVERDRIVE THE FASTENER. self driller correct too loose too tight Sealing material slightly visible at edge of metal washer. Sealing material is not visible; not enough compression to seal. woodscrew Metal washer deformed; sealing matereial pressed beyond washer edge. condition of substructure: Whether over solid substrate or open structural framing, panel distortion may occur if not applied over properly aligned and uniform substructure. The installer should check the roof deck for squareness before installing Mechanical Lock ML-100 panels. Several methods can be used to verify squareness for proper installation of the panels. Method 1 Measure diagonally across one slope of the roof from similar points at the ridge and eave and obtain the same dimension. Method 2 Measure a point from the corner along the edge of the roof at a module of three (3). Measure a point from the same corner along another edge at a module of four (4). Then by measuring diagonally between the two points stablished, the dimension corner. Multiple uses of this system may be required to determine building squareness. If the endwall cannot be made square, the roof system cannot be installed as shown in these instructions. To prevent wobbling make sure fastener head is completely engaged in the socket. If the head does not go all the way in the socket tap the magnet deeper into the socket to allow full head engagement. Metal chips will build up from drilling and should be removed from time to time. Protect drill point. Push only hard enough on the screw gun to engage clutch. This prevents excess friction and burn out of the drill point. Correct pressure will allow screw to drill and tap without binding. Drilling through sheet and insulation ease up on pressure when drilling through insulation to avoid striking the purlin or girt with the pont apply more pressure after drill point contacts purlin or girt. Drilling through purlin overlaps. Drilling through lapped purlins requires extra care. Excessive voids between purlins sometimes damages drill ponts and two self drillers might be necessary to complete the operation
11 ML SERIES installation The three drawings below ilustrate the seaming process. Starting with Step 1, clips are installed over the male leg and fastened to the substrate. Step 2. involves the female leg of the adjoining panel to then be set on the male leg/clip assembly. Step 3 involves the panels to be seamed, with either a mechanical or hand seamer. The seam shown is a 90 degree seam or a 180 degree or double seam is optional. This type of seam is typically required where high wind loads are needed. Data from extensive wind step 1 Hand tool positioned over seam step 1 step 2 step 3 HAND CRIMPER step 2 Hand tool locked onto seam step 3 Hand tool crimps seam
12 2 ML SERIES installation MECHANICAL LOCK SERIES PANEL OR CURVED PANEL CONTINUOUS FACTORY APPLY VINYL WEATHER SEAL CONTINUOUS CLIP FASTENERS; 2 AT EVERY PURLIN FOR OPEN FRAMING CONDITIONS 2 FASTENERS 36 O.C. MAX. FOR SOLID SHEATING 1 3/8 11/16 1 3/ /16 2 1/4 PANEL SECTION CONTINUOUS CLIP WITH FACTORY APPLIED VINYL WEATHER SEAL MECHANICAL LOCK SERIES PANEL OR CURVED PANEL 1 3/8 PANEL SUPPORT CONTINUOUS CLIP FACTORY APPLIED EXTRUDED VINYL WEATHERSEAL PANEL SUPPORT OPTIONAL SEAM SECTION 1/
13 ML SERIES installation electric seamer: The electric seamer will run in one direction only. To determine the direction of the seamer, stand at the eave and look upslope. If the roof is being installed left to right, the seamer will run upslope. If the roof is being installed right, the seamer will run upslope, an orientation plate is on the seamer to assist you in placing the seamer onto the seam properly. Shen the roof has endlaps, the panels will always be installed right to left. When the roof slope is 6 on 12 or greater, panels must run right lo left. To begin seaming, set seamer on seam with the locking bar up and to the open side of the seam. The rear wheels should be even with the edge of the roof panel. Push the locking bar down to engage the rolls and turn the seamer on. Stop seamer about one foot from end panels. Disengage locking bar and remove the electric seamer. Finish seam with hand tool. caution Seamer operation should be closely supervised at all times. A safety line should be attached to the seamer. Do not entangle the electrical cords in the seamer tooling while it is in operation. This could couse serious injury or death to the operator and severely damage the seamer. Electrical cords should be 10-gouge to provide power to the semaer and never be over 200 feet from the electrical source
14 trim diagram 2 5 RAKE / EAVE 1 end wall ridge cap gutter valley PITCH CHANGE downspot
15 RC24-SO16 A=7 B=1 RCS24-SO16 A= 4½ B=1 C=2 D=½ PC24-SO16 A= 7 B=1 C=5 D=6 E= Z24-SO334 A=1 B= 1¾ C= VENTED ZEE AVAILABLE, PLEASE INQUIRE
16 GUS24-SO235 A=4 B=6 C=7 D=5 E=1 24 GU24-SO2114 A= 6 B= 5 C= 6 D= 4 E= 1 F= DS24-SO1618 A= 4 B= 3 14 VC24-SO24 A=4 B=1 C=5 D=1 E=1-13 -
17 CS24-SO418 A=2 B=5/8 C=1½ D=3/16 DRIP EDGE (DL) DL24-SO08 A=4 ½ B=1 C=1½ D=1½ EAVE (OFFSET CLEAT) A EC24-SO08 A=4 B=3 C=½ B C SIDEWALL SW24-SO09 A=3 B=5 C= A C B
18 J-TRIM A JC24-SO06 A=3 3/8 B=1 1/8 C=1 D=½ D B C FW24-SO1078 A=6 B=5 5/8 C=1 ¼ D=½ EW24-SO09 A=3 B=5 C=1 HIGH SIDE FASCIA FH24-SO13 A=3 B=5 C=½
19 vented z VZ24-SO414 A=1 B= 1 C=1 D= 1¾ E= B C D E endwall-q EWQ24-SO06 A=1 B= 3 C=1 D=1/ counter flashing COF24-SO45 A=¾ B=¾ C=1¼ D=1¼ E= e BOX RAKE BOR24-SO45 A=3 B= 2 ½ C=1 ½ D=5/
20 valley VA24-SO24 A=11 B= A valley single VAS24-SO25 A=11 B= b A rake B C RA24-SO1078 A=3 B=2 ½ C=5/8 D=1 E=5/8 7 ¾ 6.12 D e continuous cleat CC24 A=2 ½ B= ½ A 135 b
21 eave detail 10-12X1 WOOD SCREWS -12 O.C. ML PANEL SERIES DRIP EDGE WOOD DECK 10-12X1 WOOD SCREWS -12 O.C. CLEAT FASCIA BOARD ML PANEL SERIES 10-12X1 WOOD SCREWS -12 O.C X1 WOOD SCREWS -12 O.C. 1 SOLID DECK DRIP EDGE 2 CLEAT 1. Install cleat onto fascia with #10-12x1 wood screw 12 O.C. 2. install drip edge by sliding open hem onto cleat & fastening with #10-12x1 wood screw, 12 O.C. on to substrate. 3. Engage drip edge into open hem of panel to begin panel installation
22 gutter detail ML SERIES PANEL GUTTER STRAP POP RIVET SOLID DECK WOODGRIP 10 X 1 GUTTER FASCIA BOARD ML SERIES PANEL CLIP 1. Install all gutter flashings before panel installation. 2. Fasten back of gutter top of fascia w/ #10-12 x 1 Pancake head 24 O.C. 3. Install drip edge over back of gutter & fasten # 10-12x1 Pancake head wood 12 O.C. on top of substrate. 4. Engage field hemmed end of panel top hem of drip edge. DRIP EDGE 3 PANCAKE HEAD 10 x 1 SOLID DECK FASCIA BOARD 4 PANCAKE HEAD 10 x 1 WOODGRIP 10 X 1 POP RIVET GUTTER 1 2 GUTTER STRAP
23 hip/ridge detail RIDGE/HIP CAP FLASHING Z CLOSURE DOUBLE BEADED TYPE 1. Box ends of panels. 2. Field cut Z closures to fit between panel ribs. 3. Set Z closure in tape sealant or 2 cont. beans of sealant and attach to panel. with (3) #10-12 x1 wood screws. 4. Apply sealant on side legs of Z closure, filling any gaps around panel ribs. 5. Attach ridge/hip flashing to Z closures with a pop rivet on one side at 24 O.C. 6. If additional flashing lengths are required, apply sealant and lap the flashing over the installed flashing by a minimum of 3 securing the connection with pop rivets. ML SERIES ROOF PANEL POP RIVET ONE SIDE ONLY 5 #10-12 X 1 SCREWS 1 BOX END PANEL Z CLOSURE CUT TO FIT BETWEEN PANEL. SET IN 2 CONT. BEADS OF AND CAULKED VERTICALLY AT SEAMS. RIDGE/HIP CAP FLASHING Z CLOSURE
24 metal VENTED RIDGE DETAIL RIDGE/HIP CAP FLASHING VENTED Z PANEL DOUBLE BADED TYPE 1. Box ends of panels. 2. Set Z closure in tape sealant or 2 cont. beads of sealant and attach to panel with (3) #10-12 x 1 wood screws. 3. Attach bottom of vented Z closure to top of Z closure with stitch 24 O.C. 4. Hook other hem side of ridge cap onto the long end of the other vented Z closure and pop rivet both 24 O.C. 5. Insert long end of vented Z closure into an open hem side of ridge cap. RIDGE CAP FLASHING 3 VENTED Z PANEL POP 24 O.C. 4 5 BOX END OF PANEL 1 #10-12 X 1 SCREW (3) PER PANEL Z CLOSURE CUT TO FIT BETWEEN PANEL, SET IN 2 CONT. BEADS OF AND CAULKED VERTICALLY AT SEAMS ML SERIES ROOF PANEL Z CLOSURE 2 SOLID DECK
25 VENTED RIDGE DETAIL RIDGE CAP VENTING MATERIAL Z CLOSURE ML SERIES ROOF PANEL DOUBLE BADED TYPE 1. Box ends of panels. 2. Field cut Z closures to fit between panel ribs. Set Z closure in tape sealant or 2 cont. beads of sealant and attach to panel with (3) x 1 wood screws. 3. Apply sealant on side legs of Z closure, filling any gaps around panel ribs. 4. Attach ridge flashing to Z closures through venting material with a stich screw at 24 O.C. 5. If additional flashing over the installed flashing by a minimum of 3 securing the connection with pop rivets. 1 BOX END OF PANEL 4 RIDGE CAP VENTING MATERIAL STITCH SCREW #10-12 X 1 SCREWS PER PANEL Z CLOSURE CUT TO FIT 2 3 BETWEEN PANEL, SET IN 2 CONT. BEADS OF AND CAULKED VERTICALLY AT SEAMS ML-SERIES ROOF PANEL
26 GABLE DETAIL ML SERIES ROOF PANEL GABLE FLASHING SOLID DECK CLEAT #10-12 X 1 WOOD 12 O.C. STITCH SCREW AT 12 O.C. 5 ML SERIES ROOF PANEL 2 CONT. BUTYL TAPE 3 SOLID DECK GABLE FLASHING 4 CLEAT 1 1. Install cleat on to fascia with #10-12x1 pancake wood screws at 12 O.C. 2. Field bend panel at 90 degrees 1-1/2 minimum. 3. Adhere a continuous length of butyl tape onto the top inside of the panel leg. 4. Slide gable flashing onto cleat and align with panel. 5. Connect gable flashing with a stitch screw at 12 O.C. #10-12 X 1 WOOD 12 O.C
27 valley DETAIL ML SERIES ROOF PANEL OFFSET CLEAT VALLEY FLASHING #10-12 x 1 PANCAKE SCREWS AT 24 O.C. CONT. 3/8 x 1 BUTYL TAPE 1. Install all valley flashings before panel installation. 2. Fasten valley flashing to substrate with #10-12 x 1 pancake head wood screws 24 O.C. 3. Align and install offset cleat with tape sealant on both sides of valley flashing. 4. Fasten offset cleat through valley flashing and tape sealant to substrate with #10-12x1 pancake head wood screws 24 O.C. 5. Field hem panel. 6. Engage field hemmed end of panel to offset cleat and attach panel as usual. ROOF PANEL FIELD CUT & PANEL ML SERIES ROOF PANEL #10-12 x 1 PANCAKE SCREWS AT 24 O.C VALLEY FLASHING 5 6 OFFSET CLEAT 3 SOLID DECK CONT. 3/8 x 1 BUTYL TAPE
28 endwall DETAIL WALL SYSTEM ENDWALL FLASHING Z CLOSURE POP RIVET AT 24 O.C. #10-12 X 1 SCREWS WALL SYSTEM ENDWALL FLASHING ML SERIES PANEL ROOF #10-12 x 1 SCREWS (3) PER PANEL 1 1. Box panel ends. 2. Field cut Z closures to fit between panel ribs. 3. Set Z closure in tape sealant of cont. beads or sealant and attach to panel with (3) #10-12x-1 wood screws. 4. Caulk Z closure vertically at panel seam. 5. Attach high side transitions flashing to Z closure with pop rivets. Z CLOSURE POP RIVET AT 24 O.C. 5 Z CLOSURE CUT TO FIT BETWEEN PANEL, SET IN 2 CONT. BEADS OF AND CAULKED VERTICALLY AT SEAMS SOLID DECK
29 endwall DETAIL WOODGRIP 10 x 1 CAULKING BUTYL TAPE COUNTER FLASHING POP RIVET AT 24 O.C. ENDWALLFLASHING Z CLOSURE #10-12 X1 SCREW (3) PER PANEL SOLID DECK CAULKING WOODGRIP 10 x 1 BUTYL TAPE COUNTER FLASHING ENDWALL FLASHING 5 FIELD BOX END OF PANEL 1 6 ML SERIES ROOF PANEL #10-12 X1 SCREW (3) PER PANEL Z CLOSURE POP RIVET AT 24 O.C. 1. Box panel ends. 2. Field cut Z closures to fit between panel ribs. 3. Set Z closure in tape sealant or cont. beads of sealant and attach to panel with (3) #10-12x-1 wood screws. 4. Caulk Z closure vertically at panel seam. 5. Attach endwall flashing to Z closure with pop rivets 24 O.C. 6. Install counter flashing and caulk top with sealant. Z CLOSURE CUT TO FIT BETWEEN PANEL, SET IN 2 CONT. BEADS OF AND CAULKED VERTICALLY AT SEAMS SOLID DECK
30 endwall DETAIL ENDWALL C FLASHING POP RIVET AT 24 O.C. Z CLOSURE BUTYL TAPE CAULKING 6 ENDWALL WITH REGLET FLASHING 5 FIELD BOX END PANEL 1 ML SERIES ROOF PANEL #10-12 x 1 SCREW PANEL 1. Box panel ends. 2. Field cut Z closures to fit between panel ribs. 3. Set Z closure in tape sealant or cont. beads of sealant and attach to panel with (3) #10-12x-1 wood screws. 4. Caulk Z closure vertically at panel seam. 5. Attach endwall flashing to Z closure with pop rivets 24 O.C. and set top of flashing in wall. 6. Caulk with sealant.- Z CLOSURE POP RIVET AT 24 O.C. Z CLOSURE CUT TO FIT BETWEEN PANEL, SET IN 2 CONT. BEADS OF AND CAULKED VERTICALLY AT SEAMS SOLID DECK
31 side wall DETAIL FINISHED WALL COUNTER FLASHING FASTENER AT 24 OC BUTYL TAPE FINISHED WALL 1. Apply sealant tape to inside of panel leg. 2. Attach sidewall flashing by installing fastener at 24 O.C. through sealant tape into panel 3. Install counter flashing. 3 FASTENER COUNTER FLASHING 2 SIDEWALL FLASHING BUTYL TAPE FASTENER AT 24 O.C. 1 ML SERIES ROOF PANEL SOLID DECK
32 side wall DETAIL FASTENER AT 24 O.C. CONT. BUTYL TAPE STITCH SCREW COUNTER FLASHING SIDEWALL FLASHING CONT. BUTYL TAPE ML SERIES ROOF PANEL 1. Apply sealant tape to inside of panel leg. 2. Attach sidewall flashing by installing fastener at 24 O.C. through sealant tape into panel 3. Install counter flashing and caulk with sealant. FASTENER AT 24 O.C. CONT. BUTYL TAPE 3 COUNTER FLASHING 2 SIDEWALL FLASHING BUTYL TAPE STITCH SCREW 1 ML SERIES ROOF PANEL SOLID DECK
33 side wall DETAIL FASTENER COUNTER FLASHING SIDEWALL FLASHING FASTENER ML SERIES ROOF PANEL 1. Apply sealant tape to inside of panel leg. 2. Attach sidewall flashing by installing fastener at 24 O.C. through sealant tape into panel 3. Install counter flashing and caulk with sealant. 3 COUNTER FLASHING 2 SIDEWALL FLASHING BUTYL TAPE 1 FASTENER ML SERIES ROOF PANEL SOLID DECK
34 ridge/hip cap RIDGE / HIP CAP POP RIVET FASTENERS, (5) PER PANEL Z CLOSURE BUTYL TAPE ML SERIES PANEL 18 GA. STEEL BACK UP PLATE OR WOOD BLOCKING METAL DECK 5 RIDGE / HIP CAP FASTENERS, (5) PER PANEL BOX PANEL END POP RIVET 2 FASTENERS, (5) PER PANEL BUTYL TAPE BUTYL TAPE 1. Box ends of panels. 2. Field cut Z closures to fit between panel ribs. 3. Set Z closure in tape sealant or 2 cont. beans of sealant and attach to panel. with (3) #10 x 1 screws 4. Apply sealant on side legs of Z closure, filling any gaps around panel ribs. 5. Attach ridge/hip flashing to Z closures with a pop rivet on one side at 24 O.C. 6. If additional flashing lengths are required, apply sealant and lap the flashing over the installed flashing by a minimum of 3 securing the connection with pop rivets. METAL DECK
35 VALLEY WITH INTEGRAL CLEAT VALLEY WITH INTEGRAL CLEAT ML SERIES PANEL FILL PANEL HEM WITH BUYTL PANCAKE FASTENER, 12.C. RIGID INSULATION PLATE OR WOOD BLOCKING CAULK BETWEEN WEBS FILL PANEL HEM W/ BUTYL ML SERIES PANEL FASTENER 12 0.C /2 INSULATION METAL DECK 1 VALLEY 12 OVERLAP
36 GUTTER ML SERIES ROOF PANEL EAVE FLASHING WOOD BLOCKING PANCAKE FASTENERS, 12 O.C. METAL DECK BUTYL TAPE FASTENER 12 O.C. CLEAT STRAP GUTTER ML SERIES ROOF PANEL 4 PANCAKE FASTENERS, 12 O.C. BUTYL TAPE CAULK BETWEEN WEBS FASTENER, 12 O.C. 1-1/2 INSULATION METAL DECK CLEAT 2 EAVE FLASHING 3 WOOD BLOCKING STRAP GUTTER 1 2. Install cleat on to wood blocking with #10 x 1 pancake wood screws 12 O.C
37 EAVE APPROVED ML SERIES ROOF PANEL BUTYL TAPE WOOD BLOCKING PANCAKE FASTENERS, 12 EAVE FLASHING FASTENER 12 O.C. CLEAT METAL DECK ML SERIES ROOF PANEL PANCAKE FASTENERS 12 O.C. CAULK BETWEEN WEBS BUTYL TAPE INSULATION METAL DECK FASTENER 12 O.C. EAVE FLASHING 2 WOOD BLOCKING CLEAT 1 1. Install cleat on to wood blocking with #10 x 1 screws 12 O.C. 3. Engage drip edge into open hem of panel to begin panel installation
38 eave 90 INSULATION PANCAKE FASTENERS, 12 O.C. ML SERIES ROOF PANEL RAKE FLASHING FASTENER 12 O.C. CLEAT METAL DECK WOOD BLOCKING ML SERIES ROOF PANEL PANCAKE FASTENERS, 12 O.C. METAL DECK INSULATION WOOD BLOCKING FASTENER 12 O.C. CLEAT 1 RAKE FLASHING 2 1. Install cleat on to wood blocking with 10 x 1 screw 12 O.C. 2. Install Rake Flashing by siding open hem on to cleat and fastening with #10-1 screws 12 O.C. 3. Engage Drip Edge into open hem of panel
39 sidewall FASTENER, 12 O.C. SIDEWALL FLASHING Z CLOSURE ML SERIES ROOF PANEL BUTYL TAPE BUTYL TAPE BASE DRIP 2 Z CLOSURE SET IN BUTYL TAPE ATTACHED W/ (5) FASTENERS PER PANEL FASTENER, 12 O.C. BUTYL TAPE ML SERIES ROOF PANEL BOX PANEL END 1 SIDEWALL FLASHING PANEL, BOX, PANEL END 1 SD FASTENERS (3) PER PANEL 4 Z CLOSURE POP RIVET 6 3 FASTENER, 12 O.C. BASE DRIP 1. Box panel end. 3. Set Z closures in the tape sealant of cont beds of sealant and attach to panel with #10-1 screws. 4. Caulk Z closure vertically at panel seam
40 RAKE RAKE FLASHING Z CLOSURE ML SERIES ROOF PANEL FASTENERS, 12 O.C. BOX END OF PANEL BUTYL TAPE WOOD BLOCKING RAKE FLASHING ML SERIES ROOF PANEL BOX END OF PANEL 1 FASTENERS, 12 O.C. Z CLOSURE WOOD BLOCKING 1. Box panel end. 1-1/2 INSULATION 3. Set Z closures in the tape sealant of cont. beds of sealant and attach to panel with (3) #10-1 screws. 4. Caulk Z closure vertically at panel seam
41 ENDWALL FASTENER, 12 O.C. COUNTER FLASHING ENDWALL FLASHING FASTENER 12 O.C. Z CLOSURE ATTACHED W/ (5) FASTENERS PER PANEL BUTYL TAPE ML SERIES PANEL 5 COUNTER FLASHING FASTENERS, 12 O.C. ENDWALL FLASHING POP RIVET 5 BUTYL TAPE ML SERIES PANEL 1 Z CLOSURE 2 4 BUTYL TAPE 3 FASTENER (5) PER PANEL WOOD BLOCKING 1. Box panel end. 1-1/2 INSULATION METAL DECK 3. Set Z closures in the tape sealant of cont. of bead of sealant and attach to panel with #10 x 1 screws. 4. Caulk Z closure vertically at panel seam
42 ENDWALL FASTENER, 12 O.C. COUNTER FLASHING ENDWALL FLASHING FASTENER 12 O.C. Z CLOSURE ATTACHED W/ (5) FASTENERS PER PANEL BUTYL TAPE ML SERIES PANEL 5 COUNTER FLASHING FASTENERS, 12 O.C. ENDWALL FLASHING POP RIVET 5 BUTYL TAPE ML SERIES PANEL 1 Z CLOSURE 2 4 BUTYL TAPE 3 FASTENER (5) PER PANEL WOOD BLOCKING 1. Box panel end. 1-1/2 INSULATION METAL DECK 3. Set Z closures in the tape sealant of cont. of bead of sealant and attach to panel with #10 x 1 screws. 4. Caulk Z closure vertically at panel seam
43 ENDWALL SIDING FASTENER, 12 O.C. ENDWALL FLASHING FASTENER 12 O.C. WOOD BLOCKING FASTENER Z CLOSURE SIDING FASTENERS, 12 O.C. ENDWALL FLASHING POP RIVET 5 BUTYL TAPE ML SERIES PANEL 1 Z- CLOSURE 2 4 BUTYL TAPE 3 FASTENERS, (5) PER PANEL WOOD BLOCKING 1-1/2 INSULATION 1. Box panel end. METAL DECK 3. Set Z closures in the tape sealant of cont. beads of sealant and attach to panel with (3) #10-1 screws. 4. Caulk Z closure vertically at panel seam
44 ENDWALL FASTENERS 12 O.C. COUNTER FLASHING Z CLOSURE FASTENERS, (5) PER PANEL ML SERIES ROOF PANEL APPROVED FASTENERS COUNTER FLASHING FASTENERS, 12 O.C. ENDWALL FLASHING POP RIVET 5 ML SERIES PANEL 1 6 Z CLOSURE 2 4 BUTYL TAPE 3 FASTENERS, (5) PER PANEL WOOD BLOCKING 1. Box panel end. 1-1/2 INSULATION METAL DECK 3. Set Z closures in the tape sealant of cont. beads of sealant and attach to panel with (3) #10-1 screws. 4. Caulk Z closure vertically at panel seam
45 vent pipe flashing detail 1. Cut pipe boot at appropiate pipe diameter. 2. Slide the pipe boot down over the pipe using water to lubricate it of necessary. 4. Seal between base and roof with tube sealant. 5. Fasten the pipe boot with 1-1/2 woodscrew at 1-1/2 centers to complete the seal. 1-½" 1-½" Centers Pipe Boot
46 step 1 Install lower panels around curb. curb detail (chimneys & skylights) Field form legs against curb sides min. 1 high 12" min. Remove half of female leg 6 Panel Installation Direction Field trimmed female leg: Remove lower hook to allow overlapping panel condition. step 2 Install Z-Closure w/ screws at 4 o.c. double bead mastic Install butyl tape each side for seal between Z-Closure and panel. Panel Installation Direction
47 Fold curb detail (chimneys & skylights) step 3 Install sidewall and high wall Field form tabs to return around high end of curb Field form tabs to return around sides of curb Highwall flashing: hook hem onto Z-Closure Side wall flashing: hook hem onto Z-Closure Panel Installation Direction step 4 Install (2) layers of mastic tape sealant under perimeter of low wall flashing Remove material each side after field tracing profile Set flashing & field trace against curb to determine trim profile prior to cutting 12 min. Remove Excess Fold Apply sealant at trim laps typically Fastener as required by condition Panel Installation Direction
48 step 5 Install cleat and prepare for upper panel installation curb detail (chimneys & skylights) Pancake head fastener at overlap location Continuous cleat set in sealant: fasten at 4 o.c. Hex head w/ washer at exposed face Install field hemmed upper panels over low wall flashing onto cleat 6 min. lap Panel Installation Direction Sealant at Z & low wall intersection at both sides of curb step 6 6 Install final upper panel over low wall flashing onto cleat Field trim male leg: remove as shown to allow flush fit against adjacent continuous panel
49 CURB DETAIL STEP 1 POLYSTICK MTS POLYGLASS NAILER BASE ISO BOARD ML SERIES ROOF PANELS
50 CURB DETAIL STEP 2 FASTENERS INSTALL CURB OVER HIDDEN FASTENERS AREA DIRECT TO METAL DECK POLYSTICK MTS-POLYGLASS APPLY 3 LINES OF FLAT SHEET GAUGE 24 FLASHING BASE 12 MIN REMOVE HALF OF FEMALE LEG 6 6 ML SERIES ROOF PANEL PANEL INSTALLATION DIRECTION TERMINATION BENDING LAP ON HIGH RIB, CUT ON SITE step 1 step 2 step 3 step
51 CURB DETAIL STEP 3 MECHANICAL LOCK PANEL HIDDEN FASTENERS DIRECT TO METAL DECK PANEL RIB COVER (OPTIONAL) APPLY 3 LINES OF MECHANICAL LOCK PANEL 3/16 X 7/8 DOUBLE BEAD TAPE 3/32 X 1 ROLL TAPE MTS POLYGLASS
52 CURB DETAIL STEP 4 ML SERIES ROOF PANEL FASTENERS 1/4-14 x 1/4 LONG LIFE SELF TAPPING SCREWS PANEL RIB COVER (OPTIONAL) 3/16 X 7/8 DOUBLE BEAD TAPE 3/32 X 1 ROLL TAPE MTS POLYGLASS NOTE: THIS DETAIL APPLIES FOR RIGID INSULATION SYSTEM
Prior to ordering and installing materials, all dimensions should be verified by field measurements.
Important Information The application and detail drawings in this manual are strictly for illustration purposes and may not be applicable to all building designs or product installations. All projects
More informationStrongSeam SSFF1 Panel
StrongSeam SSFF1 Panel Installation Manual May 2016 12 TO 24 COVERAGE CLIP OFFSET STRIATED PANEL (2 STRIATION BEADS ON PANEL) 0.875 0.9375 26 ga. & 24 ga. UL90 #529 UL2218 Class IV/Impact UL790 Class A/Fire
More informationCentral Snap. Condition Details C SNAPDETAILS
Central Snap Condition Details D C SNAPDETAILS150612.2 The men and women at Central States Manufacturing, Inc. would like to welcome you. OUR MISSION Central States Manufacturing, Inc. is a 100% employee-owned
More informationWestern States 7/8 Corrugated
Western States 7/8 Corrugated Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer / Installers..1 Fastener Placement and Selection.2-3 Key
More informationStile. Spanish Tile Installation Guide
Stile Spanish Tile Installation Guide IMPORTANT INFORMATION THE APPLICATION AND DETAIL DRAWINGS IN THIS MANUAL ARE STRICTLY FOR ILLUSTRATION PURPOSES AND MAY NOT BE APPLICABLE TO ALL BUILDING DESIGNS OR
More informationTRIAD CORRUGATED METAL, INC.
TRIAD CORRUGATED METAL, INC. C O M M E R C I A L R E S I D E N T I A L A G R I C U L T U R A L Snap Loc Panel Guide Snap Loc metal panels are a perfect fit for residential, architectural and commercial
More informationINSTALLATION GUIDE.
INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Gerard Canyon Shake counter batten
More informationSTILE. Panel Information. Design/Installation Considerations. Flashing Profiles. Detail Conditions. Notes. Accessory Profiles. Testing Information
Table of ontents Product Page No. Product Page No. Panel Information Profile...PST-2 Panel Overview...PST-2 Flashing Profiles Eave...PST- Extended Eave...PST- leat...pst- Stile Starter...PST- Box Gutter...PST-
More informationALLMET CONTINENTAL INSTALLATION GUIDE
ALLMET CONTINENTAL INSTALLATION GUIDE www.allmet.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Allmet Continental
More information1 1/2" SSR. FABRAL The pursuit of excellence since 1967
1 1/2" SSR Detail Manual and Estimate Guide 16" 1 1 2" PROPER STORAGE When moisture remains in contact with Galvanized panels in the absence of freely circulating air, white, black or dark gray corrosion
More informationPacific Tile Counter Batten and Batten
Pacific Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation
More informationProduct Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES
5V Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES ½" 24" COVERAGE Copyright 2018, Central States Manufacturing, Inc., All Rights Reserved. D C GUID_PROD_5V_180201 The men
More informationResidential Pricing Guide
Guide TABLE OF CONTENTS Panels 5V Crimp Slimline 2 4 Accessories Flat Sheets Coils V-Groove Soffit Ridge Caps Roof Jacks Touch-up Paint Insulation Slimline Rib Cover Closure Strips Tube Sealant 6 6 7
More informationRIB PANEL INSTALLATION
GOLDIN METALS, INC. www.goldinmetals.com 12440 SEAWAY ROAD Mailing Address: 14231 SEAWAY ROAD, SUITE 7000 GULFPORT, MS 39503 (228) 896-6216, Ext. 230 FAX (228) 896-4873 4400 PETERS ROAD P.O. BOX 700 HARVEY,
More informationSECTION METAL ROOF PANELS
SECTION 07 41 13 PART 1 GENERAL 1.1 SECTION INCLUDES A. Standing-seam roof panels. B. Metal roofing accessories. 1.2 RELATED SECTIONS A. Section 07 62 00 - Sheet Metal Flashing. B. Section 07 72 00 - Roof
More information238T and 138T Panel and Accessories Price List 9/29/2017 (price good for shipments through 11/31/2017) Customer Job Date Sales Rep 238T PANEL ITEM #
238T and 138T Panel and Accessories Price List 9/29/2017 (price good for shipments through 11/31/2017) Customer Job Date Sales Rep 238T PANEL ITEM # DESCRIPTION SELLING PRICE UOM 238T 238T Seam Cap 24
More informationKS SERIES - VERTICAL INSTALLATION
CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV
More informationUNA-CLAD Metal Roofing Systems Application Guide
UNA-CLAD Metal Roofing Systems Application Guide UC-3 Double-Lock Architectural Series UC-4 No-Clip Architectural Series UC-6 Double-Lock Structural Series UC-14 Snap-Lock Standing Seam Series March 22,
More informationSL150 Guide Specification
SL150 Guide Specification This is a suggested guide specification for metal roofing projects where the SL150 panel system is applicable. Questions regarding applicability should be discussed with Union
More informationLight-Metal Roof Edge, Raised
NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED
More informationINSTALLATION MANUAL Heritage Series
INSTALLATION MANUAL Heritage Series STEEL ROOF PANELS HEAD OFFICE 1418 Michael St., Ottawa, ON K1B 3R2 WATS LINE: 1 800-267-0860 TEL.: 1 613-746-3206 FAX: 1 613-746-0445 Contents Page Introduction, Storage..
More informationCS-100 Guide Specifications
MANUFACTURER CUSTOM-BILT METALS 1333 Corporate Drive, Suite 103 Irving, Texas 75038-2520 (800) 826-7813 or info@custombiltmetals.com www.custombiltmetals.com CS-100 Guide Specifications This Guide Specification
More informationDETAIL MANUAL A COMPREHENSIVE GUIDE TO METAL ROOFING GULFLOKTM HIDDEN SCREW METAL ROOF SYSTEM
DETAIL MANUAL A COMPREHENSIVE GUIDE TO METAL ROOFING GULFLOKTM HIDDEN SCREW METAL ROOF SYSTEM Gulf Coast Standing Seam Roofing Panels Since 2004, Gulf Coast Supply and Manufacturing has been happy to offer
More informationMaximum thermal performance ISOLEREN INSULATED METAL PANELS INSTALLATION GUIDE
Maximum thermal performance ISOLEREN INSULATED METAL PANELS INSTALLATION GUIDE Isoleren Installation Guide ALL INFORMATION CONTAINED IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE Table of Contents
More informationBrava Spanish Tile. Installation Manual. Brava Roof Tile Phone: Fax:
Brava Spanish Tile Installation Manual Brava Roof Tile Phone: 319-338-5706 Fax: 319-343-1038 www.bravarooftile.com This document includes the recommended and suggested installation procedures for Brava
More informationTABLE OF CONTENTS IMAGE II. Detail Conditions. Panel Information. Flashing Profiles
TABLE OF ONTENTS Product Page No. Product Page No. Panel Information Profi les...pim-2 Panel Overview...PIM-2 Flashing Profiles Eave...PIM-3 Extended Eave...PIM-3 leat...pim-3 Offset leat...pim-3 5K Gutter...PIM-3
More informationT-Rib Roofing System
T-Rib Roofing System Installation Manual 3449 Hempland Road Lancaster, PA 17601 (717) 397-2741 308 Alabama Blvd. Jackson, GA 30233 (770) 775-4484 World Wide Web: www.fabral.com E-Mail: fabinfo@fabral.com
More informationCentral Seam Plus. Central-Loc
Central Seam Plus Central-Loc Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES 3" 3" " or 18" COVERAGE " or 18" COVERAGE Central Seam Plus Field seamed Central-Loc Snaps together
More informationHANDBOOK OF CONSTRUCTION DETAILS
HANDBOOK OF CONSTRUCTION DETAILS ARCHITECTURAL PRODUCTS FOR THE BUILDING INDUSTRY 12" SSR, Decor-Flush 7, Amp Lok, Double Lock, GrandCurve, High Seam, Posi-Lock Soffit, Slim Seam 7, Snap-on-Batten, Snap-On-Seam,
More informationSECTION PRE-ENGINEERED BUILDING INSULATION
PART 1 GENERAL SECTION 07213 PRE-ENGINEERED BUILDING INSULATION Microsoft Word Instructions: Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text". 1.1 SECTION INCLUDES A. Pre-Engineered
More informationPATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge
Assembly Manual 8x9 PATENTS ARE PENDING Approximate Size 7640303 Storage Area Building Dimensions Exterior Dimensions Roof Edge to Roof Edge Interior Dimensions Wall to Wall Sq. Ft. Cu. Ft. Width Depth
More informationSpecifications for FL-100 Soffit Panel
Union Corrugating Company Specifications for FL-100 Soffit Panel SECTION 07410 METAL SOFFIT PANELS PART 1 GENERAL 1.1 DESCRIPTON A. Section Includes: 1. Preformed metal soffit panel system 2. Associated
More informationCentral Span. Product Guide 16" COVERAGE HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES
Central Span Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES 2" 16" COVERAGE Copyright 2018, Central States Manufacturing, Inc., All Rights Reserved. D C GUID_PROD_CentralSpan_180201
More informationGuardian-Lok. Standing Seam Roof System THIS MANUAL APPLIES TO GUARDIAN-LOK SYSTEMS. GUARDIAN-LOK REQUIRES PANEL SIDELAPS TO BE MECHANICALLY SEAMED.
Standing Seam Roof System Erection Manual THIS MANUAL APPLIES TO GUARDIAN-LOK SYSTEMS. GUARDIAN-LOK REQUIRES PANEL SIDELAPS TO BE MECHANICALLY SEAMED. THIS MANUAL REPLACES ALL PREVIOUS MANUALS / JC & JEN
More informationCentral Texas Metal Roofing Supply Co., Inc NET COVERAGE SHEET WIDTH
1 2 " 1 24" GAUGE PANEL FINISH NET COVERAGE SHEET WIDTH WEIGHT PER SQ. 26 5 Vee GALVALUME 24 26 3/8 95.00 PRICE PER SQ. PRICE PER LINEAR FOOT PANEL PRICING: 1. Price per Square is based on 26 3/8 sheet
More informationCentral Texas Metal Roofing Supply Co., Inc 36" NET COVERAGE SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 40 ¼ 40 ¼
36" 1 2 " 6" GAUGE PANEL FINISH NET COVERAGE SHEET WIDTH WEIGHT PER SQ. 26 26 26 26 24 24 24 24 TEXAS RIB CHANNEL GUARD TEXAS RIB CHANNEL GUARD TEXAS RIB CHANNEL GUARD CHANNEL GUARD CHANNEL GUARD GALVALUME
More informationINSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK
INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK A. 1. Using curb ribs as a guide, layout and mark roof openings on completed roof deck as outside curb
More informationJackson Plant: 308 Alabama Blvd. Jackson, GA (800) /Fax: (800)
Jackson Plant: 308 Alabama Blvd. Jackson, GA 30233 (800)884-4484/Fax: (800)765-4484 Idabel Plant: Rt. 3 Idabel, OK 74745 (800)926-8509/Fax: (800)289-6007 Headquarters: Lancaster Plant: 3449 Hempland Road
More informationNUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS
NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS Nucor VR16 II Vertical Rib Standing Seam Roof System...2 Nucor VR16 II Property and Span Tables...3 Standard Details...5 ED3010PE - Gutter...5
More information1 1/2 SSR INSTALLATION GUIDE AGRICULTURAL LIGHT COMMERCIAL RESIDENTIAL
1 1/2 SSR INSTALLATION GUIDE AGRICULTURAL LIGHT COMMERCIAL RESIDENTIAL Due to Product improvements, changes and other factors, Fabral reserves the right to change or delete information herein without prior
More informationRS32 Multi-Section Skylight System under/over seam clip double diverter
INSTALLATION INSTRUCTIONS RS32-x RS32 Multi-Section Skylight System under/over seam clip double diverter www.rnssales.com sales@rnssales.com 805.375.3980 Fax 805.375.3981 SKYLIGHT ACRYLIC skyline series
More informationPIPE. Central Texas Largest Distributor. Structural Steel, Pipe and Metal Building Components
Central Texas Largest Distributor Structural Steel, Pipe and Metal Building Components PIPE Waco Location P.O. Box 154485 913 South Loop Dr. Waco Texas 76705 Local - 254-754-2611 Bryan Location 9401 E.
More information200 / 300 SERIES PANELS COLD STORAGE
CS-DS-01-200/300 DISCLAIMER CS-CD-01-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CS-CD-02-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CONTINUED CI-PP-01-200 PANEL PROFILES 200 SERIES
More informationSECTION METAL ROOFING MASTER SPECIFICATION
SECTION 07 41 13 METAL ROOFING MASTER SPECIFICATION PART I - GENERAL REQUIREMENTS 1.01 DESCRIPTION OF WORK: A. Section Includes: The extent of each type of preformed metal roofing panel as indicated on
More informationPBR & PBU Panels. Technical/Installation Information
PBR & PBU Panels Technical/Installation Information TABLE OF CONTENTS A. PBR Panel 1. General Description..................................................................... 2 2. Architect/Engineer Information............................................................
More informationPBR & PBU PANELS. Technical/Installation Information
PBR & PBU PANELS Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE Retro-R PANELS. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS
More informationGuardian. Standing Seam Roof System. Manual THIS MANUAL REPLACES ALL PREVIOUS MANUALS EFFECTIVE JANUARY 1, 2006 / JC & JEN
Guardian Standing Seam Roof System Erection Manual THIS MANUAL REPLACES ALL PREVIOUS MANUALS / JC & JEN IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE GUARDIAN
More informationFOR FIELD USE PLEASE DISTRIBUTE TO THE ERECTION CREW
COVER INSTRUCTIONS FOR INSTALLING NBS CLASSIC ROOF FOR FIELD USE PLEASE DISTRIBUTE TO THE ERECTION CREW WATERLOO, IN 305 Industrial Parkway Waterloo, IN 46793 Phone: 260-837-7891 Fax: 260-837-7384 SWANSEA,
More informationCLIP-LOC. Panel Information. Detail Conditions. Flashing Profiles. Notes. Accessory Profiles. Testing Information. Design/Installation Considerations
LIP-LO Table of ontents Product Page No. Product Page No. Panel Information lip-loc Panel Profile... PL-2 Panel Overview... PL-2 Flashing Profiles Eave... PL- leat... PL- Box Gutter... PL- Box Gutter End...
More informationCentral-Span Installation Guide
Central-Span Installation Guide 2 1 7/8.08 16.00 COVERAGE.100 D C CSPANINSTALL140903 The men and women at Central States Manufacturing, Inc. would like to welcome you. OUR MISSION Central States Manufacturing,
More informationSECTION EXTERIOR GRILLS AND SCREENS
SECTION 10 82 13 PART 1 GENERAL PART 1 1 SUMMARY A. Section Includes: 1. Exterior perforated aluminum screen wall system with Ombrae TM Optical Tile imaging technology. 2. Accessories including attachments,
More informationS BI COM P ON E NT CA T ALOG
SBI METAL BUILDINGS & COMPONENTS S BI COM P ON E NT CA T ALOG Date: 03 / 16 / 2017 COMMERCIAL PRODUCTS Commercial Panels and Trim Cee, Zee, Eave Struts, Angle, Channel, and Clips Accessories FT 0 1 2 3
More informationMIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 NOTICE OF ACCEPTANCE
More informationGuide Specification SDP 200
PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Sheet metal roofing panels, metal trim, accessories, fasteners, closures, and sealants. [Specifier Note: Edit paragraph below to suit project requirements.]
More informationSECTION ROOF SPECIALTIES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable
More informationAgenda. Safety Decking Basics Decking Issues Felt Kick Out Flashing Fascia
Decking & Fascia Agenda Safety Decking Basics Decking Issues Felt Kick Out Flashing Fascia 2 Chapter 7 Tools & Materials Tools for Decking Hammer Measuring Tape Chalk Line Speed Square Utility Knife Circular
More informationSECTION 07530CP EPDM MEMBRANE ROOFING
PART 1 GENERAL 1.1 SUMMARY SECTION 07530CP EPDM MEMBRANE ROOFING A. Section includes: 1. Adhered membrane roofing and flashing 2. Mechanically fastened roof insulation 3. Walkway pads 1.2 ARCHITECTURAL
More informationSECTION MANUFACTURED ROOF AND WALL PANELS SECTION SHEET METAL ROOFING
SPECIFICATIONS www.englertinc.com MANUFACTURER ENGLERT, INC. 1200 Amboy Avenue Perth Amboy, New Jersey 08861 Tel: (732) 826-8614 Fax: (732) 826-8865 PART I - GENERAL 1.01 WORK INCLUDED SECTION 07410 -
More informationCentral Snap. Product Guide. 16" or 18" COVERAGE 1¾" HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES
Central Snap Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES 1¾" 16" or 18" COVERAGE Copyright 2018, Central States Manufacturing, Inc., All Rights Reserved. D C GUID_PROD_CENTRALSNAP_180201.1
More informationINSTALLATION MANUAL. METAL INSULATED PANELS -ROXUL -Expanded Polystyrene
INSTALLATION MANUAL METAL INSULATED PANELS -ROXUL -Expanded Polystyrene Insulated Metal Panels London Eco-Metal Manufacturing Inc. **Also see Eco-Metal s Handling Manual** These instructions are provided
More informationStudent Services & Classroom Addition
SECTION 095133 - ACOUSTICAL METAL PAN CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
More informationapplication instructions
application instructions FOUNDATIONS 76 & 120 SERIES PRIMED PANEL SIDING ARCHITECTURAL COLLECTION REVERSE BOARD & BATTEN AND STUCCO PANEL SIDING General At the time of manufacture, siding meets or exceeds
More informationGeneral. 2. Design. 3. Anchor Bolts And Foundations. 4. Drawings. 5. Structural Framing. 6. Roof Covering Nucor Classic Roof Panel
The following Nucor Building Systems Specification Guide provides the owner or design professional a detailed description of all standard Nucor Building Systems (NBS) products. This guide is designed to
More informationSECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof
SECTION 07550 MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof This section is based on the products of MFM Building Products Corp., which is located at: 525 Orange St. P. O. Box 340 Coshocton, OH 43812
More informationMetafor Panel System Installation Guide
Installation Guide innovative cladding design solutions Product Description Universal Flashing Kit Supplemental Guide for VM Pro-Zinc Training To enroll in a VM PRO-ZINC Training Course contact: UMICORE
More informationRS24-10 Single-Section Skylight System
INSTALLATION INSTRUCTIONS RS24-10 VERSION 1.100316 DATED: 10/03/16 RS24-10 Single-Section Skylight System under/over seam clip double diverter US Patent D750,282 www.rnssales.com sales@rnssales.com 805.375.3980
More information5V CRIMP. Technical/Installation Information
5V CRIMP Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL OCMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE SYSTEM. ALWAYS INSPECT EACH AND EVERY PANEL AND ALL ACCESSORIES BEFORE
More informationFACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET
KPH-DS-01-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV KPH-BS-04-MTLV KPH-OC-01-MTLV KPH-IC-01-MTLV KPH-SF-01-MTLV KPH-SF-02-MTLV
More informationRetro-R DESIGN/INSTALLATION INFORMATION
Retro-R DESIGN/INSTALLATION INFORMATION IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE Retro-R PANELS. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS A MINIMUM TO
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION SECTION 07320 TWO-PIECE TAPERED MISSION CLAY ROOFING TILE PART 1 GENERAL 1.01 SECTION INCLUDES A. Formed clay roofing tiles, complete with components and other required accessories
More informationDAN S CUSTOM SHEETMETAL Manufacturer and Distributor
About the Company DAN S CUSTOM SHEETMETAL Manufacturer and Distributor In 1993, DCSM was the first manufacture in the state of Florida to fabricate metal eave closure for tile. We have established a reputation
More informationBattenLok HS. Technical/Installation Information
BattenLok HS Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE ROOFING SYSTEM. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS A MINIMUM
More informationHip Detail. Construction Details. KS1000 LP/CR Roof. Hip Detail STANDARD ENHANCED ENHANCED STANDARD. Mineral fibre insulation
Hip Detail Hip Detail STANDARD Mineral fibre insulation ENHANCED Hip flashing with 150mm sealed butt straps Panels site cut to suit rake angle Apex dam (Ref: LP1/A) Rake cut profiled filler sealed top
More informationGeneral. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings
application instructions STRAND SUBSTRATE 38, 76 AND 190 SERIES PRIMED PANEL SIDING INCLUDING SILVERTECH & SMARTFINISH General At the time of manufacture, siding meets or exceeds the performance standards
More informationROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION
ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION Revised September 14 The General Trade Knowledge portion of the examination is administered daily in Computer Based Testing (CBT)
More informationGeneral Overview SECTION PBR & R PANEL - PREFORMED ROOF AND WALL PANELS
SECTION 07410 - PREFORMED ROOF AND WALL PANELS # Specifier: Notation (#) means that text following is a specifier s note or sample. PART 1 - GENERAL 1.01 Description # Specifier: Do not alter paragraph
More informationLP SmartSide Perfection Shingle
Application Instructions Fiber Substrate Lap Siding A A - Lap Siding ON SITE STORAGE Store off the ground well supported, on a flat well-drained surface. (Diagram 1a) Additional support may be required
More informationIndustry Standard Terms & Definitions Of The Steel Deck Institute
Industry Standard Terms & Definitions Of The Steel Deck Institute A specialized set of jargon to describe common terms used by manufacturers and other professionals associated with the usage of Steel Deck
More informationLINEAR METAL CEILINGS Section
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
More informationFORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual
FORM HEADWALL (floor mount) Installation Manual FORM HEADWALL (floor mount) OVERVIEW The Form is a UL-listed configurable headwall system. This system includes multiple horizontal equipment channels integrated
More informationCity of Republic Community Development Department. Residential Roofs REVISION DATE: JANUARY 2017
City of Republic Community Development Department Residential Roofs REVISION DATE: JANUARY 2017 A residential roof permit is required for new roofs and for replacement roofs when the replacement area is
More informationA. Source Limitations: Obtain each type of building insulation through one source.
SECTION 07210 - BUILDING INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationSiding and Soffit Installation Guidelines
Siding and Soffit Installation Guidelines email web phone 07 46 16 Longboard Siding & Soffit INTRODUCTION INSTALLATION GUIDELINES NOTE: These instructions are prepared for persons experienced in the field
More informationChapter 7. Roof Framing
Chapter 7. Roof Framing 7.1 ROOFING PREP WORK 7.2 INSTALLING ROOF TRUSSES 7.3 INSTALLING PORCH TRUSSES 7.4 SHEATHING ROOF 7.5 INSTALLING SUB-FASCIA 7.6 BUILDING AND INSTALLING SCUTTLE BOX 7.7 INSTALLING
More informationSECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications
SECTION 07 42 13 INSULATED METAL WALL PANELS ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications PART 1 GENERAL 1.1. Summary The contract drawings indicate
More informationKingspan Day-Lite Klick
Insulated Panel Envelope Systems Roof Wall Façades Lighting Rooftop PV Coldstore Structural Products Cleanrooms UK & Ireland Kingspan Day-Lite Klick Installation Guide Page 2 Accessories Overview Designation
More informationPrestige Roofing System
Prestige Roofing System Installation Manual 3449 Hempland Road Lancaster, PA 17601 (800) 477-2741 308 Alabama Blvd. Jackson, GA 30233 (800) 884-4484 World Wide Web: www.fabral.com E-Mail: architecturalsystems@fabral.com
More informationSECTION MANUFACTURED ROOF AND PANELS SECTION SHEET METAL ROOFING
SPECIFICATIONS www.englertinc.com MANUFACTURER ENGLERT, INC. 1200 Amboy Avenue Perth Amboy, New Jersey 08861 Tel: (732) 826-8614 Fax: (732) 826-8865 PART I - GENERAL 1.01 WORK INCLUDED SECTION 07410 -
More informationSECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM
PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.
More informationKBS-100 SNAP-LOCK PANEL & 5V PANEL I N S T A L L A T I O N M A N U A L
KBS-100 SNAP-LOCK PANEL & 5V PANEL I N S T A L L A T I O N M A N U A L KBS Metal Roofing KBS Metal Roofing General Information General Information Before beginning installation of panels, the installer
More informationInstruction Manual for Installing OutBack Steel-Framed Buildings. Gambrel Buildings
Instruction Manual for Installing OutBack Steel-Framed Buildings Gambrel Buildings Copyright OutBack Steel Buildings 2014 Last updated 5/10/2014 2 Instruction Manual for Installing OutBack Steel-Framed
More informationRoof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208
Notes: Drawing Index T-1 Title R-1 Roof Plan - Existing Conditions R-2 Roof Plan - New D-1 Roof Details D-2 Roof Details D-3 Roof Details M-1 Mechanical - Roof Plan M-2 Mechanical - Details Roof Key Plan
More informationPRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
More informationSLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017]
[Change these specifications as needed. Use this sample proposal at your own risk. This is a simple, general proposal and is not meant to be a comprehensive proposal for all situations or projects. If
More informationENGINEERED SOLUTIONS SAFETY INSTRUCTIONS FOR STRUCTURAL PLATE PRODUCTS
ENGINEERED SOLUTIONS SAFETY INSTRUCTIONS FOR STRUCTURAL PLATE PRODUCTS UNLOADING HANDLING ASSEMBLING Preface This instruction book is for your crews. Distribute it to help them safely unload and handle
More information29 Gauge. Technical/Installation Information
Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE 29 GAUGE LOW PROFILE PANELS PANELS. THE MANUFACTURER DETAILS MUST BE FOLLOWED
More informationKingZip. Insulated Standing Seam Roof System. Insulated Metal Wall Systems Installation Guide
KingZip Insulated Standing Seam Roof System Insulated Metal Wall Systems Installation Guide Contents Introduction 3 Material Handling 4 Inspection Upon Delivery 4 Panel Handling 5 Panel Storage on Site
More informationCITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO
SECTION 07220 - ROOF INSULATION PART 1 - GENERAL 1.01 DESCRIPTION A. Work included: The Roofing Contractor will provide all polyisocyanurate insulation and high density wood fiber roof insulation (tapered
More informationTop Ten List: What Gets Metal Roof Designers in Trouble?
Top Ten List: What Gets Metal Roof Designers in Trouble? Brian Gardiner, FRCI, RRC, CCS BMG Enterprises, LLC 180 elvira, Canyon lake, TX 78133 Phone: 512-784-3791 e-mail: brian.bmgent@gmail.com Charlie
More informationOREGON ROOF CONSULTING - ROOF INSPECTION FORM
Oregon CCB: 199121 PO Box 220190, Milwaukie, OR 97222 Washington License: OREGORC871MR OREGON ROOF CONSULTING - ROOF INSPECTION FORM General Roof Conditions: NA = Not Applicable Debris on Roof Physical
More information