Electrical & Mechanical Services Enclosures - Designer Selector Table
|
|
- Buck Tate
- 5 years ago
- Views:
Transcription
1 Designer Selector Table 8 Electrical & Mechanical Services Enclosures Integrity & Insulation Product Fire Rating Collar Size Mineral Wool VICUCLAD or VICUTUBE 0mm thick 0/0/0 80mm x 0mm thick mm x kg/m 0mm thick 0/0/0 80mm x 0mm thick 0mm x 80 kg/m 0mm thick 0/0/0 80mm x 0mm thick 0mm x 80 kg/m PROMATECT -H mm thick 0/0/0 00mm x mm thick 0mm x 0 kg/m mm thick 0/0/0 00mm x mm thick 0mm x 80 kg/m 0mm thick 0/0/0 00mm x 0mm thick 00mm x 00 kg/m PROMATECT -L00 0mm thick 0/0/0 00mm x mm thick 0mm x 00 kg/m 0mm thick 0/0/0 00mm x mm thick Not required 0mm thick 0/0/0 00mm x mm thick 0mm x 80 kg/m mm thick 0/0/0 00mm x mm thick 00mm x 0 kg/m.mm thick 0/0/0 00mm x.mm 0mm x 0 kg/m Electrical & Mechanical Services Enclosures Integrity Only Product Fire Rating Collar Size Mineral Wool PROMATECT -H mm thick 0/0/- 00mm x mm thick Not required mm thick 0/0/- 00mm x mm thick Not required PROMATECT -L00 mm thick 0/0/0 00mm x mm thick Not required 0mm thick 0/0/0 00mm x mm thick Not required mm thick 0/0/- 00mm x mm thick Not required.mm thick 0/0/0 00mm x.mm thick Not required
2 Integrity Only & Insulation Afterwards Cladding of Existing Sheet Metal Ducts 8 to hour(s) fire rating, integrity and insulation in accordance with the criteria of BS : Part 0 and AS 0: Part ; internal or external fire. VICUCLAD or PROMATECT boards, PROMATECT -H strips, 00mm wide x mm thick where applicable VICUCLAD or PROMATECT collar, size in accordance with Installation Method 0 0 Detail Cross section through duct Steel channel collar minimum 0mm x 0mm x 0.mm at butt joints of nominal 0mm centres M self-tapping screws at nominal 00mm centres For hours fire rating: Threaded rod hanger stress not to exceed 0 N/mm For hours fire rating: Threaded rod hanger stress not to exceed N/mm, or -sided construction: ( hours fire rating) Steel angle minimum 0mm x 0mm x 0.mm ( hours fire rating) Steel angle minimum 0mm x 0mm x mm -sided construction: Steel angle minimum 0mm x 0mm x 0.mm 8 M self-tapping screws at nominal 00mm centres or steel staples mm x 0mm x mm at nominal 00mm centres General E & M services e.g. cable trunking and steel pipes, etc 0 Mineral wool, requirement in accordance with Cantilever arm at maximum 0mm centres NOTE: Solutions for the construction of systems with, and -side used in combination with walls and ceilings are approved, details on request. Detail Longitudinal section through duct 8 Alternative board Detail Fixing to steel angle to board edge fixing The above details are applicable for enclosures not exceeding 0mm wide, PROMATECT enclosures for E&M services are approved for widths up to m, please consult your local Promat technical department for details. The above specifications are applicable for providing a fire resistance level in accordance with the integrity and insulation requirements of BS : Part 0 and AS 0: Part and relate to compartmentation. The constructions as detailed above do not necessarily provide sufficient insulation performances to ensure that the services contained therein will continue to function under fire conditions. If in doubt, please contact your local Promat Technical Department.
3 Integrity Only & Insulation Enclosure Cladding Details TITLE? ACTION BY KENNY Detail -sided enclosure Detail -sided enclosure (Case ) 0 Detail -sided enclosure 0 0 Detail 8 -sided enclosure Detail -sided enclosure (Case ) NOTE: Please consult your local Promat Technical Department for construction details for enclosures widths over 0mm.
4 Integrity Only 8 Afterwards Cladding of Existing Services For the provision of fire resisting constructions to cable ducts and general building services in accordance with the performance criteria of BS : Part 0 and AS 0: Part. As no specific British Standard exists to such applications, Promat constructions have been tested in accordance with the criteria of German DIN or British Standard BS : Part, and appraised to BS : Part 0. The appraisals include allowance for both internal and external fire. The integrity and where pertinent the insulation performance of the enclosure, and any penetrations through compartment walls and floors, is measured. Circuit integrity of electrical cables, or ability of the services to function are not measured and do not constitute part of the failure criteria. Where circuit integrity of electrical cables are required, please refer to the PDF (Study of Electrical Cables for External/Internal Fire). For the provision of a protection system which will ensure the ability of any other services to function in case of fire remains unimpaired, e.g. fuel pipes, water mains, please consult the Promat Technical Department. Installation Method hours fire rating, integrity in accordance with the criteria of BS : Part 0 and AS 0: Part ; internal or external fire. Fire protection boards, Steel channel collar minimum 0mm x mm x 0.mm at butt joints of nominal 0mm centres E & M services like cable trunking and steel pipes, etc Hanger diameter sized to limit stress not to exceed 0 N/mm M self-tapping screws at nominal 00mm centres Steel angle minimum 0mm x 0mm x 0.mm at corners hours fire rating, integrity in accordance with the criteria of BS : Part 0 and AS 0: Part ; internal or external fire. Fire protection boards, Steel channel collar minimum 0mm x mm x 0.mm at butt joints of nominal 0mm centres E & M services like cable trunking and steel pipes, etc Installation Method Hanger diameter sized to limit stress not to exceed N/mm M self-tapping screws at nominal 00mm centres Steel angle minimum 0mm x 0mm x 0.mm at corners NOTE: Solutions for the construction of systems with, and -side used in combination with walls and ceilings are approved, details on request. Detail Fixing to steel angle Detail Butt joint detail For enclosure with a width exceeding 0mm, the steel channel collar shall be spaced at centres such to ensure a maximum unsupported area not exceeding.m. The maximum approved width of the construction details herein is 000mm. If the E & M service being encased is a plastic pipe, external hangers and angles with stress 0 N/mm will be required to independently support the enclosure.
5 PS 8 PROMATECT fi -S ENCLOSURES enclosures provide protection against fire to cable ducts and general building services in accordance with the relevant criteria of BS : Parts 0 and, and AS 0: Part. systems are eminently suitable for providing protection to services even under extremely aggressive environments. The systems described below ensure the integrity of fire compartments. If the services are required to continue functioning in the event of fire, please consult the Promat Technical Department. The maximum permissible dimensions for enclosures are up to 000mm x 000mm for up to 0 minutes fire resistance. 8 Installation Method Single-skin system required to ensure the integrity of fire compartmentation and to contain smoke and flame from ignited cables. boards, thickness in accordance with Steel flanges, fabricated by cutting and welding 0mm x 0mm x mm thick angles, the flanges are bolted together with M0 nuts and bolts at nominal 00mm centres to form continuous sections Cable tray or services enclosure Corner steel angle reinforcement, 0mm x 0mm x mm thick, these corner angles do not require any mechanical fixing to the flanges 8 Installation Method Maintaining the circuit integrity of the cables. Support channels, sized according to duct weight, size and required fire-resistance Steel hanger rods, sized according to duct weight, size and required fire-resistance Mineral wool, requirement in accordance with 8 Cables or services 8 Installation Method Maintaining the circuit integrity of the cables.
The Passive Fire Protection Handbook
The Passive Fire Protection Handbook The UK s comprehensive guide to passive fire protection Chapter Ceilings, Floors and Roofs AUGUST 0 The Passive Fire Protection Handbook Contents Chapter : Introduction
More informationPROMAtect 50 Structural steel. progressivematerials.com.au
PROMAtect 50 Structural steel 08 9445 8300 info@progressivematerials.com.au progressivematerials.com.au STRUCTURAL STEEL FIRE PROTECTION PROMATECT 50 Cement Bound Matrix Board General Information 3 Definition
More informationFIREPRO FIRE DUCT SYSTEMS Single layer fire protection for rectangular, circular and oval ducts.
FIREPRO FIRE DUCT SYSTEMS Single layer fire protection for rectangular, circular and oval ducts. FIRE DUCT SYSTEMS Rectangular and circular, single layer fire protection for steel ductwork. As part of
More informationPromat PROMASEAL Fire Barrier
Promat PROMASEAL Fire Barrier PRODUCT DESCRIPTION Promat PROMASEAL Fire Barriers are slabs of high density rock wool with a white endothermic, ablative coating. APPLICATION Promat PROMASEAL Fire Barriers
More informationPARTITIONS & EXTERNAL WALLS 5
PARTITIONS & EXTERNAL WALLS INTERNAL PARTITIONS CONVERSION OF EXTERNAL WALL TO INTERNAL WALL TECHNICAL DATA 30 minutes fire rating, integrity and insulation in accordance with the criteria of BS 7: Part
More informationPyroscat Duct Wrap XL
Datasheet Code US: - 0 Thermal Ceramics is a business of Morgan Advanced Materials * Commonly referred to test method CA Section 00 is CDPH Standard Method for the Testing and Evaluation of Volatile Organic
More informationFireMaster FastWrap XL
Datasheet Code US: 7--6 MSDS Code US: 06 009 Morgan Thermal Ceramics, a business within the Morgan Ceramics Division of The Morgan Crucible Company plc Grease Duct Enclosure System Air Ventilation Duct
More informationSECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS
SECTION 26 05 29 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide all labor, materials, equipment, and incidentals as shown, specified, and
More informationFireMaster FastWrap XL
Datasheet Code US: 7-14-36 MSDS Code US: 406 009 Morgan Thermal Ceramics, a business within the Morgan Ceramics Division of The Morgan Crucible Company plc * Commonly referred to test method CA Section
More informationFire Barrier Duct Wrap 615+
Fire Barrier Duct Wrap 615+ Duct Wrap Fire Protection System for Commercial Kitchen Grease and Ventilation Air Ducts Product Data Batts and blankets for use in fire resistive duct assemblies see UL fire
More informationPROMATECT -S Smoke & Fire Barrier
PROMATECT -S Smoke & Fire Barrier Introduction The purpose of a cavity barrier is to prevent the spread of smoke and flame from penetrating and/or moving within a concealed space in a fire compartment.
More informationThe Passive Fire Protection Handbook. Chapter 3: Structural Steel
Chapter 3: Structural Steel 43 Chapter 3: Structural Steel - Introduction The amount of fire protection required to achieve this depends on the following: Duration of fire resistance specified Type of
More informationFIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250
FIRE PROTECTION GTEC Shaftwall range uses a specially designed system to protect voids and shafts in buildings. It resists pressure changes and enables installation from one side of the shaft only. GTEC
More informationUL Design System HW-D-1012 continued
UL System No. HW-D-1012 Assembly Ratings 1, 2 and 3 Hr (See Item 2) Nominal Joint Width 3 in. Class II and III Movement Capabilities 100% Compression or Extension Page 1 of 5 1. Floor Assembly The fire-rated
More informationPart E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,
Part E Pack Dear Colleague, This is the first 2017 update to the Part E Robust Details Handbook. In this update pack, we have focussed on clarifying the situation on incorporating underfloor heating (UFH)
More informationB. Qualification Data: For installers specified in Quality Assurance article.
SECTION 233113 METAL DUCTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationPROMATECT 50 Protection For Structural Steelwork
Protection For Structural Steelwork Contents PROMATECT 50 Cement Bound Matrix Board General Information / Definition & Calculations For 2 Calculation of Hp/A Values 4 PROMATECT 50 Column Cladding 5 PROMATECT
More informationCERTIFICATE OF APPROVAL No CF 663 HILTI AG
CERTIFICATE OF APPROVAL No CF 663 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of BU Chemicals, Feldkircherstrasse
More informationSECTION HVAC DUCTS AND CASINGS
SECTION 23 31 00 HVAC DUCTS AND CASINGS PART 1 -GENERAL 1.1 SUMMARY A. Section includes metal ductwork, nonmetallic ductwork, casing and plenums, buried ductwork, kitchen hood ductwork, duct cleaning.
More informationLuka Quality Assurance Manual (Eng)
Luka Quality Assurance Manual (Eng) Contents: 1 General... 3 1.01 Foreword... 3 2. Quality assurance standards for air ducts... 4 A.1.00 Rectangular galvanised steel ducts... 4 A.2.00 Embedded galvanised
More informationFire Prevention K90 and K30 dampers in accordance with DIN Part I 09/2006
Fire Prevention K90 and K30 dampers in accordance with DIN 4102-6 Part I 09/2006 40 30 20 50 L W db(a) 45 L W db(a) Total pressure loss pt [Pa] 10 6 4 35 L W db(a) 2 400 600 800 1000 1400 2000 2600. Volume
More informationBRE Global Ltd Watford, Herts WD25 9XX. d+b facades (UK) Ltd. The Packway, Larkhill, Salisbury, SP4 8PY. Customer Services
BRE Global Test Report BS 8414-1:2015 + A1:2017 test on d+b facades rain screen cladding system with 100mm-thick Rockwool insulation and aluminium cassette panels. Prepared for: d+b facades (UK) Ltd. Date:
More information3M Fire Barrier Duct Wrap 615+ Product Data Sheet and Installation Guide (Condensed Version)
M Fire Barrier Duct Wrap + Product Data Sheet and Installation Guide (Condensed Version) FIRE BARRIER UP TO Fire Protection HOUR FLEXIBLE WRAP GREASE & AIR DUCT Fire Protection. Product Description M Fire
More informationModel 4010 Individual Panels / Curve & Diverter
Model 4010 Individual Panels / Curve & Diverter Introduction: The following three (3) part specification offers the Standard and Optional features for the Model 4010 Curve & Diverter Operable Wall System.
More informationREGULATORY INFORMATION REPORT. An assessment of the fire resistance of CSR Hebel external wall panels if tested in accordance with AS
REGULATORY INFORMATION REPORT An assessment of the fire resistance of CSR Hebel external wall panels if tested in accordance with AS1530.4-2005. EWFA Report No: RIR 24648-07 Report Sponsor: CSR Panel Systems
More informationSeismic Restraints. Cent-R-Rail Supplement* SYSTEMS THAT MAKE SENSE
SRSCR-0 Seismic Restraints Cent-R-Rail Supplement* Multi-Directional Bracing For Data-Track, Half-Rack and Multi-Tier Half-Rack Systems Structural Engineer S 9 *To be used in conjunction with Cooper B-Line
More informationStandard Installation Fire Damper Models: 119, 119(F), 119(SS), D19
Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19 Page 1 or 8 APPLICATION This fi re damper is intended to restrict the passage of fl ame. The standard installation requires that the
More information11/2 HOUR UL CLASSIFIED CURTAIN TYPE (D)IBD2, (D)IBD2SS AND IBDT FIRE DAMPERS
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 INSTALLATION INSTRUCTIONS 11/2 HOUR UL CLASSIFIED CURTAIN TYPE (D)IBD2, (D)IBD2SS AND IBDT FIRE DAMPERS APPLICATION The fire
More informationCERTIFICATE OF APPROVAL No CF 816 BIP GMBH
CERTIFICATE OF APPROVAL No CF 816 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of St Peter Straβe 25 (Chemiepark
More informationDuct Wrap 2x2 Duct Wrap 2x2+ Commercial Kitchen Grease Duct
Fire Protection Systems Commercial Kitchen Grease Duct Product Data & Installation Guide NFPA 96 IMC 1. Product Description Thermal Ceramics and are foilencapsulated, non-combustible, inorganic, flexible
More informationDesign & Construction Standards, Revised January
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationTrench Duct Class Catalog 5230CT9601R10/08
5230CT9601R10/08 2009 Class 5230 CONTENTS Application.................................................5 Unassembled Trench Duct Components.........................6 Factory Assembled Trench Duct..............................11
More informationNORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS
PART 1 GENERAL 1.01 SUMMARY Section 15140 PIPE HANGERS, This Section includes the furnishing and subsequent installation of: A. Pipe and equipment hangers, supports, and associated anchors B. Equipment
More informationLISTING INFORMATION OF Weyerhaeuser - TJI Joists SPEC ID: 26948
LISTING INFORMATION OF Weyerhaeuser - TJI Joists SPEC ID: 26948 Weyerhaeuser NR Company 33663 Weyerhaeuser Way S PO Box 9777, WTC 1K5 Federal Way, WA 98063 This report is for the exclusive use of Intertek
More informationSECTION STEEL DECKING
SECTION 05 31 00 STEEL DECKING SPEC WRITER NOTE: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. Refer to Section 05 36 00, COMPOSITE METAL DECKING for floor
More informationCavity fire barriers. Cavity fire barriers. Fire separation within concealed spaces. C06 Floors and ceilings
Fire separation within concealed spaces Regulatory requirements demand that cavities and concealed spaces, in the structure or fabric of a building, are sub-divided or sealed by means of cavity barriers
More informationICC-ES Evaluation Report Reissued May 1, 2010 This report is subject to re-examination in two years.
ICC-ES Evaluation Report ESR-1255 Reissued May 1, 2010 This report is subject to re-examination in two years. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MINERAL FIBER FIREPROOFING REPORT HOLDER: UNIFRAX I LLC
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2224 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00
More informationThe Passive Fire Protection Handbook
Chapter 2: User Guide Promat DURASTEEL 18 Promat DURAWALL 19 Promat MASTERBOARD 20 Promat TD Board 22 Promat PROMASEAL Products 23 Promat PROMATECT -250 24 Promat PROMATECT -L500 26 Promat SUPALUX 28 Promat
More informationCavity ShAftwall System
09 9 00/NGC Cavity shaftwall systems are non-load-bearing, -hour to -hour, fire-rated partitions constructed from one side used to enclose elevator shafts, stairs and mechanical shafts where the design
More informationFC /2 Hour Curtain Fire Dampers
FC-2000 1-1/2 Hour Curtain Fire Dampers Installation Instructions 44-3521- 0, Rev. B Part No. 44-3521-0, Rev. B Issued March 2016 Applications Johnson Controls provides a 1-1/2 hour curtain fire damper
More informationC05. S03. P02 P08 FireWall
! This section includes updated information, added since it was first published in December 2015. Last updated 16/12/2016 C05. S03. P02 P08 Including C05. S01. P02 Specialist partitions introduction C05
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB #
SECTION 26 0529 - HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
More informationMaterials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.
Concrete inserts offered in this section are designed to provide a pre-set support point in concrete ceilings, walls, and floors. A range of inserts with varying design loads are available. Materials Carbon
More informationB. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.
SECTION 230529 - HANGERS AND SUPPORTS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe hangers and supports. 2. Hanger rods. 3. Inserts. 4. Flashing. 5. Sleeves. 6. Mechanical sleeve seals. 7. Firestopping
More informationIntumescent Pipewrap Roll
FIRESTOPPING December 2016 Intumescent Pipewrap Roll ROCKWOOL FirePro Intumescent Pipewrap Roll offers a simple and more economical alternative to Firestop Collars and avoids the need to carry a wide range
More informationSECTION HANGERS AND SUPPORTS FOR PLUMBING
SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationFastWrap+ 1 1 /2 Commercial Kitchen Grease Duct Air Ventilation Duct
FastWrap+ 1 1 /2 Commercial Kitchen Grease Duct Air Ventilation Duct Fire Protection Systems Product Data and Installation Guide NFPA 96 IMC 1. Product Description - New and Improved FastWrap+ Thermal
More informationPIPEWORK INSULATION. 14/ Page 1 of 10 Pipework Insulation Rev D
PIPEWORK INSULATION 14/10-2014 Page 1 of 10 Pipework Insulation Rev D Contents INTRODUCTION General Scope Surfaces to be Insulated Pumps, Turbines etc Performance Minimum Pipe Insulation Thickness Physical
More informationFIRESTOP AND FIRE PROTECTION
FIRESTOP AND FIRE PROTECTION 170 Firestop Sealants, Sprays High-performance intumescent firestop sealant FS-ONE MAX Page 172 Flexible firestop sealant CP 606 Page 172 Elastomeric silicone sealant CP 601S
More informationCERTIFICATE OF APPROVAL No CF 563 SIDERISE INSULATION LIMITED
CERTIFICATE OF APPROVAL No CF 563 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Forge Industrial Estate,
More informationStructural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)
Inspection of Fabricators (1704.2) Furnish inspection reports (1704.2.1) - Fabricators that have not been approved Provide a Certificate of Compliance (1704.2.2) - Approved Fabricators Steel Construction
More informationFire Protection Valves
4/4/EN/6 Fire Protection Valves Type FV-K90 FVZ-K30 with German Test Certificate (General Building Approval) Z-41.3-317 Z-41.3-319 TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/202-265 Heinrich-Trox-Platz
More informationInterior Hangers. Application
Application Interior bridge deck hangers are typically fabricated using two heavy duty sheet metal end clips that have been electrically resistance welded to an appropriate sized wire or formed metal connecting
More informationA. This Section includes acoustical panel ceilings installed with exposed suspension systems.
SECTION 09511 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification
More informationSYSTEMS+ SPECIALTY SYSTEMS INNOVATIVE SYSTEMS SOLUTIONS USGBORAL.COM
USGBORAL.COM S+ I 2 INTRODUCTION I 8 LIFT & SERVICES SHAFTS I 8 Shaftwall I 9 Ventshaft I 10 COLUMN PROTECTION I 13 BEAM PROTECTION I 14 FIRE TUNNEL I SPECIALTY S INNOVATIVE S SOLUTIONS I SPECIALTY S INTRODUCTION
More informationSECTION SEISMIC CONTROL OSHPD
SECTION 01451 PART 1 - GENERAL 1.01 DESCRIPTION A. Provide all required seismic restraints and calculations in order to insure that the installation of all architectural, mechanical, and electrical equipment/components
More informationLISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848
LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848 International Fireproof Technology Inc. 17528 Von Karman Avenue Irvine, CA 92614 This report is for the exclusive
More informationProduct Catalogue 2017
T M Product Catalogue 2017 Second Edition Distributed by PASSIVE FIRE-STOPPING FLOWCHART (Basic Service Penetrations) Plan Identify what is required. Is the wall fire rated? If so, what is the fire rating?
More informationSPECIFICATION FOR TUBULAR STEEL LIGHTING COLUMN. Reference is made in this Specification to the following:
SPECIFICATION FOR TUBULAR STEEL LIGHTING COLUMN 1. SCOPE This specification covers the design, fabrication and testing of tubular section, galvanised steel friction fit jointed street light columns of
More informationFig. 1 - Standard Clevis Hanger
Revision 10/24/2007 Fig. 1 - Standard Clevis Hanger Component of State of California OSHPD Approved Seismic Restraints System Size Range Size 1/2" thru 36" pipe. Function Recommended for the suspension
More informationProspective Construction Systems for Mass Housing
Prospective Construction Systems for Mass Housing TECHNOLOGY PROFILE Light Gauge Steel Framed Structures (LGSF) Building Materials & Technology Promotion Council Ministry of Housing & Urban Poverty Alleviation
More informationCHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION
CHAPTER 26 PLASTIC SECTION BC 2601 GENERAL 2601.1 Scope. These provisions shall govern the materials, design, application, construction and installation of foam plastic, foam plastic insulation, plastic
More informationStanding Seam Systems. NBS Specification. KingZip SF Standing Seam Roofing System
NBS Specification KingZip SF Standing Seam Roofing System H31 METAL PROFILED/FLAT SHEET CLADDING/COVERING To be read with Preliminaries/General conditions. TYPE OF CLADDING SYSTEM 140 METAL PROFILED CLADDING
More informationFIRE AND SMOKE PROTECTION FEATURES
CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES SECTION 70 GENERAL 70. Scope. The provisions of this chapter shall govern the materials, systems and assemblies used for structural fire resistance and fire-resistance-rated
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.
0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1143 Reissued 04/2017 This report is subject to renewal 04/2018. DIVISION: 07 00 00 THERMAL
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 26 0526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationTER No Attachment of Exterior Wall Coverings Through Kingspan GreenGuard Extruded Polystyrene (XPS) Sheathing to Wood or Steel Wall Framing
Attachment of Exterior Wall Coverings Through Kingspan Insulation LLC 2100 RiverEdge Parkway Suite 175 Atlanta, GA 30328 kingspaninsulation.us TER No. 1410-09 Issue Date: January 30, 2015 Updated: March
More informationProduct Information High Performance Building Dow Corning Firestop 700 Silicone Sealant
Product Information High Performance Building Dow Corning Firestop 700 Silicone Sealant FEATURES & BENEFITS Meets BS 476 Part 22 Excellent unprimed adhesion to most porous and non-porous construction substrates
More information1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.
SECTION 260529 - HANGERS AND SUPPORTS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. 1.2
More informationDesign guide to separating distances during construction, Part 4
TRUCTURAL TIMBER ASSOCIATION Building solutions in timber Design guide to separating distances during construction, Part 4 For CLT type frame buildings Version. - November 204 Thanks to KLH and Binderholz
More informationSmoke Control Damper ESAM Instructions for installation, operation and maintenance 10/2014
Instructions for installation, operation and maintenance 0/204 General The rectangular smoke control damper ESAM is specially designed for use in multi fire-compartment applications as a closing or opening
More informationINDEX. S. No. Description Page No.
ECOPROO BOARDS & (NON-ASBESTOS) PANELS USER S MANUAL 1 2 INDEX S. No. Description Page No. 1. Introduction... 5 2. Ecopro Boards & Panels... 6 3. Special Features... 7 4. Partitions... 9 5. Partition System
More informationFIRESTOP 101: An Introduction to Firestopping
FIRESTOP 101: An Introduction to Firestopping Role of Firestop What is Firestopping? A process whereby certain materials, some of them specially manufactured, are used to resist (or stop) the spread of
More informationACOUSTICAL INSULATION (LAGGING) FOR PIPING AND EQUIPMENT
ACOUSTICAL INSULATION (LAGGING) FOR PIPING AND EQUIPMENT Specification for Acoustical Insulation (Lagging) for Piping and Equipment 1 of 5 TABLE OF CONTENTS 1.0SCOPE..... 3 2.0REFERENCED PUBLICATIONS...
More informationfischer Test Report Fixing Tests for Bison Hollow Core Slabs
fischer Test Report Fixing Tests for Bison Hollow Core Slabs Testing on Bison Hollow Core Slabs 1. Introduction Contents Test Parameters Bison Hollow Core Slab Information 2. Fixings Products Tested FISV
More informationPatent No. 9,045,900 Technical Glass Products Architectural Specification Manual
Technical Glass Products Architectural Specification Manual 800.426.0279 fireglass.com FIREFRAMES ALUMINUM SERIES INTERIOR APPLICATION ONLY Fireframes Aluminum Series combined with Pilkington Pyrostop
More informationLoadbearing timber joist floors
C06 Floors and ceilings Internal and separating floor systems Timber joists are widely used within internal floor and separating floor construction, both in residential and coercial applications. Our range
More informationPipe Joints. Requirements and Test Methods. VdS-Guidelines for water extinguishing systems. VdS en. VdS en : (01)
VdS-Guidelines for water extinguishing systems VdS 2100-6en Requirements and Test Methods Reproduction prohibited even for internal use VdS 2100-6en : 2004-01 (01) Publisher and Publishing house: VdS Schadenverhütung
More informationPRESTON HEALTH SERVICES ARCHITECT'S NO. 2700
SECTION 09 5113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT
Page 220529-1 SECTION 220529 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationCERTIFICATE OF APPROVAL No CF 517 FSI LIMITED
CERTIFICATE OF APPROVAL No CF 517 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Westminster Industrial
More informationCOOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.
SECTION 092900 GYPSUM BOARD PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationTER No Attachment of Exterior Wall Coverings Through Kingspan GreenGuard Extruded Polystyrene (XPS) Sheathing to Wood or Steel Wall Framing
Attachment of Exterior Wall Coverings Through Kingspan Insulation LLC 2100 RiverEdge Parkway Suite 175 Atlanta, GA 30328 kingspaninsulation.us TER No. 1410-09 Issue Date: January 30, 2015 Updated: August
More informationRISER DETAIL NTS SHANNON FIRE PROTECTION, LLC SCALE: 3/32" = 1'-0"
MAXIMUM DISTANCE BETWEEN HANGERS NOMINAL PIPE SIZE (in.) 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 3-1/2" 4" 5" 6" 8" STEEL PIPE EXCEPT THREADED LIGHTWALL THREADED LIGHTWALL STEEL PIPE COPPER TUBE 10-0 10-0 CPVC
More informationSECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT
SECTION 220529 - HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The General Conditions, Special Conditions and Division 1 through Division 22 as set forth in
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards
Date Description of Change Pages / Sections Modified ID 6/15/16 Updated format, division title, and removed references to other sections. - mgl44 A. Summary This section contains design criteria for the
More informationSECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT
SECTION 23 05 29 HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes pipe and equipment supports, hangers, anchors, bases sleeves and the sealing of work
More informationDURA-BLOK Rooftop Supports
Cooper B-Line s new line of DURA-BLOK products gives you a versatile and long-term solution for all your roof top support needs. Designed with flexibility in mind, Dura-Blok is ideal for roof top support
More informationDivision 11 - Equipment Section 11401
PART 1 - GENERAL 1.1 GENERAL A. Division 1 General Requirements applies and becomes a part of this Section of the Specification as fully as if repeated herein. B. Items of equipment which are included
More informationSEISMIC RESTRAINTS Multi-Directional Bracing For Electrical Conduit, Cable Tray And Mechanical Piping Systems
SEISMIC RESTRAINTS Multi-Directional Bracing For Electrical Conduit, Cable Tray And Mechanical Piping Systems SYSTEMS THAT MAKE SENSE INTRODUCTION INTRODUCTION What is Seismic Bracing? Seismic forces are
More informationA. Pipe Supports: ANSI B 31.1, Power Piping. B. Automatic Sprinkler Pipe Supports: Refer to Section
SECTION 15140 SUPPORTS, ANCHORS, AND SEALS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract including General and Supplementary Conditions, Division 1 Specification
More informationifix INSTALLATION MANUAL PV flat roof installation system Version
ifix PV flat roof installation system INSTALLATION MANUAL Version 2012-09-06 ifix Installation Manual Version 2012-09-06 Seite 1 Table of contents Table of contents... 1 Special characteristics of ifix...
More informationFIRE STATION 55 June 14, 2010
SECTION 15250 MECHANICAL INSULATION PART 1 - GENERAL 1.01 DESCRIPTION A. Work Includes 1. Insulation of Domestic Water Piping. 2. Pipe Insulation of refrigerant piping. 3. Insulation of ductwork. 4. Aluminum
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3435 Reissued 07/2017 This report is subject to renewal 07/2018. DIVISION: 07 00
More informationSeries 3000 Pocket Doors
Series 3000 Pocket Doors Introduction: The following three (3) part specification offers the Standard and Optional features for the Series 3000 Pocket Doors. The yellow highlighted areas in the specification
More informationSECTION METAL DUCTS
SECTION 15815 METAL DUCTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
More information2000 POCKET DOOR TECHNICAL DATA
2000 POCKET DOOR TECHNICAL DATA KWIK-WALL... One Source for Wall Systems. KWIK-WALL s s for the 2000 Series - Steel Panel operable wall systems answer the challenge for space division needs posed by multi-purpose
More informationEuropean Technical Assessment. ETA-11/0372 of Member of. General part
INSTITU Schenkenstrasse 4 T +43 1 533 65 50 1010 Vienna Ι Austria F +43 1 533 64 23 www.oib.or.at Ι mail@oib.or.at Designated according to Article 29 of Regulation (EU) No 305/2011 Member of www.eota.eu
More informationSECTION NON-PENETRATING PORTABLE ROOFTOP SUPPORTS AND WALKWAYS. For best results, display hidden notes to specifier.
SECTION 15062 NON-PENETRATING PORTABLE ROOFTOP SUPPORTS AND WALKWAYS PART 1 GENERAL 1.1 SECTION INCLUDES For best results, display hidden notes to specifier. A. Portable, non-penetrating, rooftop support
More information