RESIDENTIAL SEISMIC RETROFITS

Size: px
Start display at page:

Download "RESIDENTIAL SEISMIC RETROFITS"

Transcription

1 RESIDENTIAL Barry H. Welliver Structural Engineer BHW Engineers SEAU 6th Annual Education Conference Davis Conference Center - Layton, Utah February 21st, 2018 TOPICS Introduction to Seismic Retrofits for Residential Buildings Building Codes and Programs (Legal & Ethical Responsibilities) Beyond the Building Codes (Sound Advice / State of the Art) Client Relations (Figuring Out the Scope of Work) Unreinforced Masonry Residential Buildings The Utah Guide for the Seismic Improvement of Unreinforced Masonry Dwellings URM Rehabilitation Example Other Residential Buildings Salt Lake City s Fix the Bricks Program Questions? (and maybe some answers)

2 FOR RESIDENTIAL BUILDINGS BUILDING CODES AND PROGRAMS International Existing Building Code (IEBC) Replaces Chapter 34 (Existing Buildings) in the 2015 IBC. The provisions of the International Existing Building Code shall apply to matters governing the repair, alteration, change of occupancy, addition to and relocation of existing buildings. Mandated, Triggered and Voluntary requirements: Mandatory generally targeting specific building types or features. (Active programs) Triggered requirements are generally invoked when altering the vertical or lateral capacity of the existing building. (Passive Programs) Voluntary rehabilitation is when owner chooses to upgrade vertical or lateral capacities of the building. FOR RESIDENTIAL BUILDINGS BEYOND BUILDING CODES Seismic Evaluation and Retrofit of Existing Buildings ASCE/SEI Stated of the art - deficiency-based procedures Techniques for the Seismic Rehabilitation of Existing Buildings FEMA 547/2006 Edition Chapter 21 - Building Type URM: Unreinforced Masonry Bearing Walls Engineering Guideline for Incremental Seismic Rehabilitation FEMA 420 / December 2008 Chapter 4 - Engineering Resources for Seismic Evaluation and Rehabilitation Section Code Rationalizations for Incremental Seismic Rehabilitation Building codes allow existing buildings to remain in use without having to fully comply with the requirements for new buildings. This is generally referred to as nonconforming rights

3 FOR RESIDENTIAL BUILDINGS CLIENT RELATIONS Most clients don t know what they need to know. Some know they probably need to do something. Others are incorporating seismic into a remodel or addition. You are (usually) their best source for the technical stuff Giving advice is a dance don t get into the weeds (too soon) Admit that you re probably not the best source for costs. But don t punt entirely. Think about the larger picture ask questions about what they are trying to achieve. But are you their only source of information and advice? Recommend consultants when appropriate Geologist, architect, soils engineers, etc. Contractors may be hard to find Look beyond the anxiety. UNREINFORCED MASONRY BUILDINGS

4 THE UTAH GUIDE FOR SEISMIC IMPROVEMENTS UNREINFORCED MASONRY DWELLINGS THE UTAH GUIDE FOR THE SEISMIC IMPROVEMENT OF UNREINFORCED MASONRY DWELLINGS THE UTAH GUIDE FOR SEISMIC IMPROVEMENTS UNREINFORCED MASONRY DWELLINGS Utah Seismic Safety Commission Existing Buildings Committee Second Edition 2016

5 TABLE OF CONTENTS ACKNOWLEDGMENTS... CHAPTER 1 Introduction... CHAPTER 2 How to Use This Guide... CHAPTER 3 Building Dynamics and Earthquake Forces... CHAPTER 4 Typical Features of Unreinforced Masonry (URM) Construction... CHAPTER 5 Typical Unreinforced Masonry Homes and Deficiencies... Model A Single Story, Double Wythe Brick with Basement... Model B Single Story, Double Wythe Brick with Basement and Attic... Model C Two Story, Stucco-Covered Double Wythe Brick with Shelf Basement... Model D Two Story, Double Wythe Brick with Shelf Basement and Attic... Model E Single Story, Single Wythe Solid Brick with Full Basement... Model F Single Story, Concrete/Cinder Block with Basement and Flat Roof... Model G Seismic Mitigation of URM Structures... Special Features... CHAPTER 6 Seismic Mitigation of URM Structures... Individual Structural Repair Details... Structural bracing: Details 20 26a... Roof anchorage and strengthening: Details Floor anchorage and strengthening: Details Wall strengthening: Details Foundation anchorage and strengthening: Detail CHAPTER 7 Non-Structural Seismic Hazards: Anchorage and Bracing CHAPTER 2 HOW TO USE THIS GUIDE Begin Seismic Improvement Review Select Model Dwelling that Best Describes Subject Structure Identify Other Model Dwellings Which Have Elements Similar To Subject Structure Estimate the Cost of Corrective Measures Review Alternative Ways to Implement Corrective Measures and Select Most Appropriate Approach Compile List of Deficiencies and Corrective Measure for Subject Dwelling Is Cost Acceptable? NO YES Phase the Project or Select Corrective Measures that are Affordable Start Construction Process Figure 14. Dwelling seismic improvement flowchart.

6 CHAPTER 4 TYPICAL FEATURES OF UNREINFORCED MASONRY The Utah Guide for the Seismic Improvement of Unreinforced Masonry Dwelli Figure 20. In-plane failure. Figure 22. Wood post support and floor/roof support. Figure 18. URM bearing wall. Figure 21. Out-of-plane failure. Figure 23. Example of roof and floor diaphragms. Figure 19. Vertical section through URM walls. CHAPTER 4 TYPICAL FEATURES OF UNREINFORCED MASONRY 14 The Utah Guide for the Seismic Improvement of Unreinforced Masonry Dwellings Figure 20. In-plane failure. Figure 22. Wood post support and floor/roof support. The Utah Guide for the Seismic Improvement of Unreinforced Masonry Dwellings 15 Special Features Most URM dwellings contain the basic structural elements described in this guide, however there are special features that may not be present in all URM dwellings or may vary from one dwelling to another. The special features covered in this guide include URM parapets, masonry gable end walls, chimneys, and corner windows (figure 25). There are other special features found on URM dwellings, however these are the most common. A description of each of these items, their deficiencies, and Figure references 21. Out-of-plane to the appropriate failure. corrective measures are included at the end of Chapter 5. 21). The floor joists usually pocket into the masonry and the roof joists normally bear on top of wall. In both cases, there may or may not be a wood plate to which these joists are nailed. Failure of these connections can cause the joists to slide off their bearing support, resulting in full or partial collapse of a floor or roof. Another common failure in multiple wythe (or vertical layer) construction where one or more of the outer wythes of brick may fall away from the rest of the wall, as they are not connected together. Masonry Piers (Columns) Figure Figure Bearing Example wall of and roof post and and floor beam diaphragms. line. Floor and Roof Diaphragms The diaphragm is the structural element that consists of sheathing fastened to the underlying joists, creating a flat floor/roof or a sloping roof, which distributes forces throughout a particular level of the dwelling (figure 23). Horizontal forces generated in the masonry walls are transferred to the diaphragms. The diaphragms in URM construction generally fail due to the large forces generated from the weight of the surrounding masonry and/or the poor connections tying the diaphragms and walls together. Masonry piers can be located within the dwelling under the Interior Bearing Walls and/or main beam line that Figure supports 25. the Examples first floor of or a parapet, at the exterior chimney gable end wall, and Post corner and window. Beam Lines to support the roof over a porch (figure 22). In both cases, the pier either continues to the floor or roof, or supports a The interior-bearing element may be an URM wall, a wood wood post that then continues to the floor or roof. These stud wall, a post and beam line, or any combination (figure piers are subject to the same type of failure as the masonry 24). This intermediate support is required because the floor foundation wall. Taller piers will have tendency to topple and roof joists generally cannot span between exterior or buckle during an earthquake. walls. These elements will normally fail from inadequate connections or lack of any connections to each other.

7 CHAPTER 5 TYPICAL URM HOMES AND DEFICIENCIES Model A Model B Model C Model D CHAPTER 5 TYPICAL URM HOMES AND DEFICIENCIES Model E Model F Figure 26. Representative model dwelling types. Model G

8 CHAPTER 5 TYPICAL URM HOMES AND DEFICIENCIES Table 1. Typical seismic improvement details for model dwelling types A to G for various seismic deficiencies. Seismic Deficiencies (In order of highest priority to lowest priority) Strengthening and Bracing of Special Features Roof to URM Wall Anchorage Floor to URM Wall and Foundation Wall Anchorage URM Wall Strengthening Roof Diaphragm Strengthening Floor Diaphragm Strengthening Strengthening of Major Interior Bearing Elements Foundation Wall Strengthening Non-Structural Bracing and Anchorage Model Dwelling Types A B C D E F G Details Details 30 and and 36 Details 20, 22, 24, 25, and 26 Details 32 and 37 Details 51, 53, and 54 Details 50, 51, 53, 54, and 56 Details 40 and 43 Detail 57 Detail 90 Details 33 and 38 Detail 34 Details 32 and 36 Details 52 and 55 Detail 51 Details 51 and 54 Details 70 and 74 Details 75 and 76 Details 77 and 82 For bracing and anchorage of non-structural items, including water heaters, furnishings, cabinets, equipment, etc., see details 100 and higher. MODEL BUILDING A -SINGLE STORY DOUBLE WYTHE W/ BASEMENT The seismic deficiencies observed in Model A are: although not illustrated in these exterior wall details. 1. The lack of anchorage of the roof to the URM exterior walls. There may or may not be a wood plate on top of the typical URM wall which this home did not have. 2. The lack of anchorage of the floor to the URM exterior and concrete foundation walls. 3. The chimneys are not braced. 4. The lack of continuous sheathing makes the roof diaphragm weak. There are 1 x 8 inch wood boards spaced at approximately 12 inches on center. 5. The masonry bearing walls are unreinforced. 6. The tall masonry porch piers are not braced or adequately attached to the porch roof. 7. The interior wood stud bearing walls are not anchored to the floor or roof. 8. The water heater is not braced and utility connections are rigid pipe.

9 28 The Utah Guide for the Seismic Improvement of Unreinforced Masonry Dwellings MODEL BUILDING A -SINGLE STORY DOUBLE WYTHE W/ BASEMENT Model A: Details 1 2 Single story, double wythe brick with basement The Utah Guide for the Seismic Improvement of Unreinforced Masonry Dwellings 77 The Utah Guide for the Seismic Improvement of Unreinforced Masonry Dwellings MODEL BUILDING C -TWO STORY DOUBLE WYTHE W/ SHELF BASEMENT for the Seismic Improvement of Unreinforced Masonry Dwellings 21 Model C Two Story, Stucco-Covered Double Wythe Brick with Shelf Basement Model C was built in the 1900s, and is a two-story home with a concrete shelf basement (figures 31 and 32). The construction consists of double wythe URM exterior walls covered with stucco, masonry/rock foundation walls supporting a wood floor and roof/ceiling joists around the exterior. A wood beam on masonry piers or wood posts supports the floor, while a wood stud wall supports the roof. It has two exterior chimneys and several small roof areas built into the dwelling. Model C o Story, Stucco-Covered ble Wythe Brick with Shelf Basement C was built in the 1900s, and is tory home with a concrete shelf t (figures 31 and 32). The construcsists of double wythe URM exterior overed with stucco, masonry/rock on walls supporting a wood floor f/ceiling joists around the exterior. beam on masonry piers or wood pports the floor, while a wood stud ports the roof. It has two exterior s and several small roof areas built dwelling. mic deficiencies observed in Model e lack of anchorage of the roof to URM exterior walls. There may or y not be a wood plate on top of the ical URM wall which this home did t have. The small areas at the front trances are also not anchored. e lack of anchorage of the floor to URM exterior and concrete foundan walls. e chimneys are not braced. e lack of continuous sheathing makes the f diaphragm weak. There are 1 x 8 inch od boards spaced at approximately 12 hes on center. Figure 31. Model C front view. The seismic deficiencies observed in Model C are: 1. The lack of anchorage of the roof to the URM exterior walls. There may or may not be a wood plate on top of the typical URM wall which this home did not have. The small areas at the front entrances are also not anchored. 2. The lack of anchorage of the floor to the URM exterior and concrete foundation walls. 3. The chimneys are not braced. 4. The lack of continuous sheathing makes the roof diaphragm weak. There are 1 x 8 inch wood boards spaced at approximately 12 inches on center. 5. The masonry/rock foundation walls have deteriorated. 6. The masonry bearing walls are unreinforced. 7. The interior wood stud bearing walls are not anchored to the floor or roof. 8. The water heater is not braced and utility connections are rigid pipe. Details 5 and 6 show two different existing exterior walls sections for Model C. Reference circles have been superimposed onto the details showing the area of the wall where seismic deficiencies normally occur. The details for improvements to strengthen Figure 31. Model C front vie

10 floor, while a wood stud roof. It has two exterior eral small roof areas built encies observed in Model anchorage of the roof to erior walls. There may or wood plate on top of the wall which this home did e small areas at the front also not anchored. Model C: Details 5 6 Two story, stucco-covered, double wythe brick with shelf basement and attic MODEL BUILDING C -TWO STORY DOUBLE WYTHE W/ SHELF BASEMENT Figure 31. Model C front view. anchorage of the floor to erior and concrete foundas are not braced. continuous sheathing makes the gm weak. There are 1 x 8 inch s spaced at approximately 12 ter. y/rock foundation walls have bearing walls are unreinforced. wood stud bearing walls are not he floor or roof. eater is not braced and utility re rigid pipe. w two different existing exterior Model C. Reference circles have d onto the details showing the ere seismic deficiencies normally for improvements to strengthen are found in Chapter 6. Table 1 details in Chapters 6 and 7 also improvements, although not exterior wall details. Figure 32. Model C rear view. 76 The Utah Guide for the Seismic Improvement of Unreinforced Masonry Dwellings Floor anchorage and strengthening: Details The Utah Guide for the Seismic Improvement of Unreinforced Masonry Dwellings MODEL BUILDING C -TWO STORY DOUBLE 55 WYTHE W/ SHELF BASEMENT

11 MODEL BUILDING E - SINGLE STORY SINGLE WYTHE W/ FULL BASEMENT The Utah Guide for the Seismic Improvement of Unreinforced Masonry Dwellings 23 Figure 35. Model E front view. Figure 35. Model E front view. Model E Single Story, Single Wythe Solid Brick with Full Basement Model E was built in approximately 1966, and is singlestory home with a full basement and a low slope roof (figures 35 and 36). The construction consists of single wythe URM exterior walls and concrete foundation walls supporting wood floor joists and roof trusses around the exterior with wood stud bearing walls supporting the interior. The roof structure extends over the carport and changes from trusses to sloped joists supported by wood beams at the ridge and ends. The end beams are carried by steel or wood columns. 5. The interior wood stud bearing walls are not anchored to the floor or roof. 6. The water heater is not braced and utility connections are rigid pipe. Model E: Details 9 10 Single story, single wythe, solid brick with full basement MODEL BUILDING E - SINGLE STORY SINGLE WYTHE W/ FULL BASEMENT The seismic deficiencies observed in Model E are: 1. The lack of anchorage of the roof to the URM exterior walls. 2. The lack of anchorage of the floor to the URM exterior and concrete foundation walls. 3. The masonry bearing walls are unreinforced. 4. The beams and columns for the carport are not anchored or braced to the roof or to the masonry walls of the dwelling. 6. The water heater is not braced and utility connections are rigid pipe. Details 9 and 10 show two different existing exterior wall sections for Model E. Reference circles have been superimposed into these details showing the area of the wall where seismic deficiencies normally occur. The details for improvements to strengthen these deficiencies are found in Chapter 6. Table 1 and the additional details in Chapters 6 and 7 also recommend other improvements, although not illustrated in these exterior wall details. Figure 36. Model E rear view.

12 The Utah Guide for the Seismic Improvement of Unreinforced Masonry Dwellings 59 MODEL BUILDING E - SINGLE STORY SINGLE WYTHE W/ FULL BASEMENT 48 The Utah Guide for the Seismic Improvement of Unreinforced Masonry Dwellings 46 The Utah Guide for the Seismic Improvement of Unreinforced Masonry Dwellings CHIMNEYS, GABLES & FOUNDATIONS

13 CHIMNEYS, GABLES & FOUNDATIONS The Utah Guide for the Seismic Improvement of Unreinforced Masonry Dwellings 47 The Utah Guide for the Seismic Improvement of Unreinforced Masonry Dwellings The Utah Guide for the Seismic Improvement of Unreinforced Masonry Dwellings Foundation anchorage and strengthening: Detail 90 CHIMNEYS, GABLES & FOUNDATIONS

14 URM RETROFIT Designer Buona Vita Design Group 9460 South Union Square #231 Sandy, Utah PROJECT # 08UT16.0 DATE : 10/24/2008 SUBMITTAL : PLANCHECK FRONT ELEVATION SCALE: 1/4" = 1'-0" FRONT ELEVATION SCALE: 1/4" = 1'-0" A RESIDENTIAL REMODEL FOR KELLY HARWARD SCHEMATIC ELEVATIONS FORT STREET DRAPER, UTAH LEFT ELEVATION SCALE: 1/8" = 1'-0" BACK ELEVATION SCALE: 1/8" = 1'-0" RIGHT ELEVATION SCALE: 1/8" = 1'-0" A3 URM RETROFIT PROJECT # 08UT16.0 DATE : 10/24/2008 SUBMITTAL : PLANCHECK A RESIDENTIAL REMODEL FOR KELLY HARWARD FORT STREET DRAPER, UTAH Structural Engineer BHW Engineers, L.L.C. 132 East South Suite 210 Draper, Utah T F Designer Buona Vita Design Group 9460 South Union Square #231 Sandy, Utah FOOTING AND FOUNDATION PLAN SCALE: 1/4" = 1'-0" NOTES: LOWER FLOOR FRAMING PLAN STRUCTURAL FOUNDATION PLAN & NOTES SCALE: 1/4" = 1'-0" NOTES: 1. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE 2006 INTERNATIONAL BUILDING CODE AS ADOPTED BY SALT LAKE CITY 2. VERIFY ALL DIMENSIONS AND CONSTRUCTION WITH ARCHITECTURAL DRAWINGS AND IN THE FIELD - REPORT ANY DISCREPANCIES TO ARCHITECT AND ENGINEER IN THE FIELD PRIOR TO PLACING ANY REINFORCING STEEL 3. ALL NEW FOOTINGS TO REST IN FIRM, UNDISTURBED NATURAL SOILS. 4. REFER TO SHEET S5 FOR TYPICAL STRUCTURAL NOTES AND DETAILS 1. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE 2006 INTERNATIONAL BUILDING CODE AS ADOPTED BY CITY OF DRAPER 2. VERIFY ALL DIMENSIONS AND CONSTRUCTION WITH ARCHITECTURAL DRAWINGS AND IN THE FIELD - REPORT ANY DISCREPANCIES TO ARCHITECT AND ENGINEER IN THE FIELD PRIOR TO PLACING ANY REINFORCING STEEL 3. ALL EXTERIOR WALLS TO BE SHEATHED WITH 1 2" PLYWOOD SHEATHING SCHEDULE A NAILING, UNLESS NOTED OTHERWISE. 4. REFER TO SHEET S5 FOR TYPICAL STRUCTURAL NOTES AND DETAILS S1

15 URM RETROFIT URM RETROFIT A RESIDENTIAL REMODEL FOR KELLY HARWARD FORT STREET DRAPER, UTAH Structural Engineer BHW Engineers, L.L.C. 132 East South Suite 210 Draper, Utah T F PROJECT # Designer 08UT16.0 Buona Vita Design Group DATE : 9460 South Union Square #231 Sandy, Utah /24/ SUBMITTAL : PLANCHECK PLAN LOWER FLOOR FRAMING PLAN STRUCTURAL FOUNDATION LAN & NOTES

16 URM RETROFIT UPPER FLOOR FRAMING SCALE: 1/4" = 1'-0" NOTES: 1. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE 2006 INTERNATIONAL BUILDING CODE AS ADOPTED BY CITY OF DRAPER 2. VERIFY ALL DIMENSIONS AND CONSTRUCTION WITH ARCHITECTURAL DRAWINGS AND IN THE FIELD - REPORT ANY DISCREPANCIES TO ARCHITECT AND ENGINEER IN THE FIELD PRIOR TO PLACING ANY REINFORCING STEEL 3. ALL EXTERIOR WALLS TO BE SHEATHED WITH 1 2" PLYWOOD SHEATHING SCHEDULE A NAILING, UNLESS NOTED OTHERWISE. 4. REFER TO SHEET S5 FOR TYPICAL STRUCTURAL NOTES AND DETAILS 5. FLOOR SHEATHING TO BE 3 4" T&G PLYWOOD WITH SCHEDULE A NAILING U.N.O. ROOF FRAMING PLAN SCALE: 1/4" = 1'-0" NOTES: 1. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE 2006 INTERNATIONAL BUILDING CODE AS ADOPTED BY CITY OF DRAPER 2. VERIFY ALL DIMENSIONS AND CONSTRUCTION WITH ARCHITECTURAL DRAWINGS AND IN THE FIELD - REPORT ANY DISCREPANCIES TO ARCHITECT AND ENGINEER IN THE FIELD PRIOR TO PLACING ANY REINFORCING STEEL 3. ALL EXTERIOR WALLS TO BE SHEATHED WITH 1 2" PLYWOOD SHEATHING SCHEDULE A NAILING, UNLESS NOTED OTHERWISE. 4. REFER TO SHEET S5 FOR TYPICAL STRUCTURAL NOTES AND DETAILS 5. ROOF SHEATHING TO BE 5 8" PLYWOOD WITH SCHEDULE A NAILING U.N.O. URM RETROFIT UPPER FLOOR FRAMING SCALE: 1/4" = 1'-0" ROOF FRAMING PLA SCALE: 1/4" = 1'-0"

17 SCALE: 1" = 1'-0" SCALE: 1" = 1'-0" S3 SCALE: 1" = 1'-0" DRAPER, UTAH FORT STREET SUBMITTAL : PLANCHECK DATE : 10/24/2008 PROJECT # 08UT16.0 URM RETROFIT Buona Vita Design Group 9460 South Union Square #231 Sandy, Utah Designer DRAPER, UTAH FORT STREET A RESIDENTIAL REMODEL FOR KELLY HARWARD BHW Engineers L.L.C South 132 East Suite 210 Draper, Utah STRUCTURAL ENGINEER Buona Vita Design Group 9460 South Union Square #231 Sandy, Utah Designer SUBMITTAL : PLANCHECK DATE : 10/24/2008 PROJECT # 08UT16.0 BHW Engineers L.L.C South 132 East Suite 210 Draper, Utah STRUCTURAL ENGINEER A RESIDENTIAL REMODEL FOR KELLY HARWARD STRUCTURAL DETAILS STRUCTURAL DETAILS URM RETROFIT SCALE: 1" = 1'-0" S3

18 URM RETROFIT STRUCTURAL DETAILS SCALE: 1" = 1'-0" URM RETROFIT

19 URM RETROFIT OTHER RESIDENTIAL BUILDINGS

20 SALT LAKE CITY S FIX THE BRICKS PROGRAM

21 SALT LAKE CITY S FIX THE BRICKS PROGRAM Thank You! Questions?

FEMA P-593 STEP-BY STEP PRESCRIPTIVE RETROFIT FOR CRIPPLE WALL BRACING & ANCHORAGE TO FOUNDATION

FEMA P-593 STEP-BY STEP PRESCRIPTIVE RETROFIT FOR CRIPPLE WALL BRACING & ANCHORAGE TO FOUNDATION INTRODUCTION Objective of provisions: The provisions of IEBC Appendix Chapter A3 are intended to reduce hazard of earthquake-induced damage (IEBC A301.1). These provisions are not intended to eliminate

More information

SEATTLE CENTRAL COLLEGE BROADWAY PERFORMANCE HALL SEATTLE, WASHINGTON STRUCTURAL EVALUATION FOR PREPARED BY PCS STRUCTURAL SOLUTIONS

SEATTLE CENTRAL COLLEGE BROADWAY PERFORMANCE HALL SEATTLE, WASHINGTON STRUCTURAL EVALUATION FOR PREPARED BY PCS STRUCTURAL SOLUTIONS STRUCTURAL EVALUATION FOR SEATTLE CENTRAL COLLEGE BROADWAY PERFORMANCE HALL SEATTLE, WASHINGTON PREPARED BY PCS STRUCTURAL SOLUTIONS NOVEMBER 1, 2017 17-733 TABLE OF CONTENTS Page I. PREFACE ii II. EXECUTIVE

More information

Mandatory Wood Frame Soft-story Retrofit Program STRUCTURAL DESIGN GUIDELINES

Mandatory Wood Frame Soft-story Retrofit Program STRUCTURAL DESIGN GUIDELINES INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LAMC Division 93 Effective: 11/22/15 DOCUMENT NO.: P/BC 2014-137 Revised: 06/07/16 Previously Issued As: N/A Mandatory Wood Frame Soft-story

More information

Project Seismic Vulnerability Assessment For SFCC District Building 33 Gough Street San Francisco, California 94103

Project Seismic Vulnerability Assessment For SFCC District Building 33 Gough Street San Francisco, California 94103 Project For SFCC District Building 33 Gough Street San Francisco, California 94103 Prepared For San Francisco Community College District 33 Gough Street San Francisco, California 94103 Prepared By Thornton

More information

Home Not Anchored to Foundation

Home Not Anchored to Foundation IDENTIFY WEAKNESSES Home Not Anchored to Foundation Houses that are not bolted to the foundation can move off their foundations during earthquakes. Go down into the crawl space the area between the first

More information

Sponsored by The Boston Association of Structural Engineers and the Structural Engineers Association of Massachusetts

Sponsored by The Boston Association of Structural Engineers and the Structural Engineers Association of Massachusetts Commonwealth of Massachusetts State Building Code 780-CMR 9 th Edition Renovation of Existing Buildings Using The International Existing Building Code IEBC 2015 with Massachusetts Amendments Sponsored

More information

EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire

EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire Additional Instructions and Clarifications 1. Please review ARC 4496 before beginning the project identification

More information

FEMA P 50 & FEMA P 50 1

FEMA P 50 & FEMA P 50 1 & Seismic Retrofit Guidelines for Detached, Single Family, Wood Frame Dwellings FEMA P 50 & FEMA P 50 1 & Seismic Retrofit Guidelines for Detached, Single Family, Wood Frame Dwellings FEMA P 50 1 & Seismic

More information

STRUCTURAL EVALUATION OF DOVER ELEMENTARY SCHOOL WEST CONTRA COSTA UNIFIED SCHOOL DISTRICT (WCCUSD)

STRUCTURAL EVALUATION OF DOVER ELEMENTARY SCHOOL WEST CONTRA COSTA UNIFIED SCHOOL DISTRICT (WCCUSD) STRUCTURAL EVALUATION OF DOVER ELEMENTARY SCHOOL WEST CONTRA COSTA UNIFIED SCHOOL DISTRICT (WCCUSD) For WLC Architects Kaiser Building 1300 Potrero Avenue Richmond, CA 94804 By DASSE Design, Inc. 33 New

More information

Plan Check No. Checked by: An Appointment Is Required for Verification

Plan Check No. Checked by: An Appointment Is Required for Verification SUPPLEMENTAL CORRECTION SHEET UNREINFORCED MASONRY (URM) RETROFIT ( 2002 LABC ) Plan Check No. Checked by: Permit Appl. # An Appointment Is Required for Verification Job Address: For appt. call: APPLICATION

More information

INSTRUCTORS GUIDE. FEMA P-593 CD, Seismic Rehabilitation Training for One- and Two-Family Wood-Frame Dwellings

INSTRUCTORS GUIDE. FEMA P-593 CD, Seismic Rehabilitation Training for One- and Two-Family Wood-Frame Dwellings INSTRUCTORS GUIDE FEMA P-593 CD, Seismic Rehabilitation Training for One- and Two-Family Wood-Frame Dwellings ****************************************************************************** This Instructors

More information

ROOME & GUARRACINO, LLC Consulting Structural Engineers 48 Grove Street Somerville, MA Tel: Fax:

ROOME & GUARRACINO, LLC Consulting Structural Engineers 48 Grove Street Somerville, MA Tel: Fax: ROOME & GUARRACINO, LLC Consulting Structural Engineers 48 Grove Street Somerville, MA 02144 Tel: 617.628.1700 Fax: 617.628.1711 March 3, 2016 Mr. Jeff Hoover, Principal Tappe Architects, 6 Edgerly Place

More information

City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax

City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA 94596 (925) 943-5834 phone (925) 256-3500 fax Issued July 22, 2010 Information Bulletin No. IB-016 DOCUMENT SUBMITTAL

More information

Simplified Seismic Assessment & Seismic Retrofit Guidelines for Detached, Single-Family, Wood-Frame Dwellings FEMA P-50 & FEMA P-50-1

Simplified Seismic Assessment & Seismic Retrofit Guidelines for Detached, Single-Family, Wood-Frame Dwellings FEMA P-50 & FEMA P-50-1 & Seismic Retrofit Guidelines for Detached, Single-Family, Wood-Frame Dwellings FEMA P-50 & FEMA P-50-1 & Seismic Retrofit Guidelines for Detached, Single-Family, Wood-Frame Dwellings FEMA P-50 & Seismic

More information

ALTERNATE DESIGN METHODOLOGY FOR UNREINFORCED MASONRY BUILDINGS

ALTERNATE DESIGN METHODOLOGY FOR UNREINFORCED MASONRY BUILDINGS INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LABC 8808 Effective: 01-01-2011 DOCUMENT NO. P/BC 2011-053 Revised: Previously Issued As: P/BC 2008-053 I. GENERAL ALTERNATE DESIGN METHODOLOGY

More information

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E. STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION Presented by: Susan L. Lasecki P.E., S.E. Presentation Outline Gravity Design Load Paths from Roof to Foundation Roof Framing Floor Framing Wall Framing Lateral

More information

Available at: Last Modified: December 2012

Available at:  Last Modified: December 2012 6.3 Architectural Components 6.3.7 Chimneys and Stacks 6.3.7.1 Unreinforced Masonry Chimney Unreinforced masonry (URM) chimneys are extremely vulnerable to earthquake damage; their behavior has long been

More information

Stone and Masonry Veneer

Stone and Masonry Veneer Stone and Masonry Veneer R703.7 Stone and masonry veneer, general. Stone and masonry veneer shall be installed in accordance with this chapter, Table R703.4 and Figure R703.7. These veneers installed over

More information

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.) DIVISION 94 VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.) SEC. 91.9401. PURPOSE. (Amended by Ord. No. 172,592, Eff. 6/28/99,

More information

#G445 Plans, 48'x28' x 10' detached garage with bonus room By SDS-CAD Specialized Design Systems

#G445 Plans, 48'x28' x 10' detached garage with bonus room By SDS-CAD Specialized Design Systems Architectural asphalt shingles and horizontal True Wood 7" Reveal siding over structural panel. Nailing schedule is 6" on ends 12" on centers 6d nails. Trusses are engineered on Bonus attic trusses 24"

More information

Supplemental Plan Check List for Unreinforced Masonry (URM) Retrofit

Supplemental Plan Check List for Unreinforced Masonry (URM) Retrofit Supplemental Plan Check List for Unreinforced Masonry (URM) Retrofit Plan Check/PCIS App #: Job Address: P.C. Engineer: Phone: (E -mail: first name.last name@ lacity.org) For instructions and other information,

More information

STRUCTURAL EVALUATION OF TARA HILLS ELEMENTARY SCHOOL WEST CONTRA COSTA UNIFIED SCHOOL DISTRICT (WCCUSD)

STRUCTURAL EVALUATION OF TARA HILLS ELEMENTARY SCHOOL WEST CONTRA COSTA UNIFIED SCHOOL DISTRICT (WCCUSD) STRUCTURAL EVALUATION OF TARA HILLS ELEMENTARY SCHOOL WEST CONTRA COSTA UNIFIED SCHOOL DISTRICT (WCCUSD) For WLC Architects Kaiser Building 1300 Potrero Avenue Richmond, CA 94804 By DASSE Design, Inc.

More information

STRUCTURAL EVALUATION OF WASHINGTON ELEMENTARY SCHOOL WEST CONTRA COSTA UNIFIED SCHOOL DISTRICT (WCCUSD)

STRUCTURAL EVALUATION OF WASHINGTON ELEMENTARY SCHOOL WEST CONTRA COSTA UNIFIED SCHOOL DISTRICT (WCCUSD) STRUCTURAL EVALUATION OF WASHINGTON ELEMENTARY SCHOOL WEST CONTRA COSTA UNIFIED SCHOOL DISTRICT (WCCUSD) For WLC Architects Kaiser Building 1300 Potrero Avenue Richmond, CA 94804 By DASSE Design, Inc.

More information

Seismic Design Requirements

Seismic Design Requirements City of Medford Municipal Code Chapter 9 Presented by the Building Safety Department THESE PROVISIONS PRESCRIBE THE DESIGN REQUIREMENTS OF EXISTING BUILDINGS UNDERGOING: CHANGE OF OCCUPANCY ADDITIONS ALTERATIONS

More information

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal Roof Size: Width: Length: Roof Type: Gable: Hip: Shed: Roof Pitch: (check one) Trusses: Rafters: Spacing of Trusses or Rafters:

More information

Pulaski County, Virginia Practical Wall Bracing

Pulaski County, Virginia Practical Wall Bracing Pulaski County, Virginia Practical Wall Bracing Based on the 2012 Virginia Residential Code The information herein provides guidelines for complying with the most common Practical Wall Bracing provisions

More information

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION Permit No. 175 Beaver Drive, P.O. Box 486 DuBois, PA 15801 Phone: 814-375-1111 Fax: 814-375-1117 Toll Free: 855-PENNSAF LOCATION OF PROPOSED

More information

CONSTRUCTION IMPORTANT TERMS AND FACTS CHAPTER 15

CONSTRUCTION IMPORTANT TERMS AND FACTS CHAPTER 15 CONSTRUCTION IMPORTANT TERMS AND FACTS CHAPTER 15 Copyright 2004 CONSTRUCTION The following are twenty key construction components and basic facts that are to be considered high priority. Please refer

More information

THE FLORIDA BUILDING CODE

THE FLORIDA BUILDING CODE THE FLORIDA BUILDING CODE 1. According to the Florida Building Code, spiral stairway treads must all be identical and rise must be sufficient enough to provide a headroom of minimum. A. 6'- 4" B. 6'- 6"

More information

Building Division Informational Handout

Building Division Informational Handout CITY OF SAN JOSÉ, CALIFORNIA Building Division Informational Handout Conventional Light Frame Construction Design Provisions 2007 CBC Handout No. 2-21 Published: 1/1/08 Page 1 of 3 This document summarizes

More information

APPENDIX A1 WIND AND SEISMIC BRACING GUIDELINE FOR ONE AND TWO FAMILY DWELLINGS AND TOWNHOUSES

APPENDIX A1 WIND AND SEISMIC BRACING GUIDELINE FOR ONE AND TWO FAMILY DWELLINGS AND TOWNHOUSES ST. LOUIS COUNTY DEPARTMENT OF PUBLIC WORKS DIVISION OF CODE ENFORCEMENT APPENDIX A1 WIND AND SEISMIC BRACING GUIDELINE FOR ONE AND TWO FAMILY DWELLINGS AND TOWNHOUSES Lateral Loads All buildings are subject

More information

SEISMIC DESIGN GUIDELINES

SEISMIC DESIGN GUIDELINES INTRODUCTION The purpose of these Seismic Design Guidelines is to provide additional information and clarification to Civil or Structural engineers in order to comply with Ordinance No. 18-O- 2767 for

More information

REPORT ON CAPITOL HILL HOUSING S UNREINFORCED MASONRY BUILDINGS

REPORT ON CAPITOL HILL HOUSING S UNREINFORCED MASONRY BUILDINGS REPORT ON CAPITOL HILL HOUSING S UNREINFORCED MASONRY BUILDINGS DATE: July 31, 2018 TO: FROM: REGARDING: Leadership Team Dylan Locati CHH s Unreinforced Masonry ( URM ) Buildings SUMMARY: The Seattle City

More information

ENG.ACA.0001F Madras. New Zealand significant. (a) spandrel 2010) were solid

ENG.ACA.0001F Madras. New Zealand significant. (a) spandrel 2010) were solid ENG.ACA.0001F.111 Figure 5.15 137 Manchester Street, pull out of the canopy supports 5.4 Clay brick URM building that have been partially or fully demolished 5.4.1 192 Madras Street This building was designed

More information

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE - 268-5161 Residential Accessory Structures This information has been compiled for the benefit of any person

More information

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses Released May 20, 2009 Updated March 9, 2011 Introduction: Wood frame structures with attached brick masonry veneer

More information

R Code and Commentary for 2012 NC Residential Code final 03/06/13

R Code and Commentary for 2012 NC Residential Code final 03/06/13 R602.10 Code and Commentary for 2012 NC Residential Code final 03/06/13 Commentary italicized and printed in red 1. Section R602.10 -- provides charging language for two simplified bracing approaches (isolated

More information

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued) 2000 IRC 1997 NEHRP Section Provision Section Provision Comments CHAPTER 3 BUILDING PLANNING R301 DESIGN CRITERIA R301.2.2 Seismic Provisions R301.2.2.1 Determination of Seismic Design Category R301.2.2.1.1

More information

Administrative Changes

Administrative Changes Revised 11/29/06 Knox County Residential Building Codes Significant Changes From The 1995 CABO One And Two Family Dwelling Code To The 2006 International Residential Code All one and two family dwellings

More information

Framing Methods Structural Components

Framing Methods Structural Components Framing Methods Structural Components Balloon Framing *Balloon framing or Eastern framing the exterior studs run from the top of the foundation to the top of the highest level. Benefits of this type of

More information

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC) Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC) Plan Check Submittal Date: Plan Check #: Permit App.# Job Address: Applicant: Phone: ( ) P.C. Engineer: Phone:

More information

R CODE CHANGE PROPOSAL FORM (See instructions on page 2)

R CODE CHANGE PROPOSAL FORM (See instructions on page 2) CODE CHANGE PROPOSAL FORM (See instructions on page 2) Code: IRC 12/13 Sections 301.2.2.2.1 Proponent: Charles S. Bajnai, Chesterfield County, VA, ICC Building Code Action Committee 1. Delete as shown

More information

* RESIDENTIAL PLAN REVIEW *

* RESIDENTIAL PLAN REVIEW * CITY OF DES MOINES, IOWA COMMUNITY DEVELOPMENT DEPARTMENT PERMIT AND DEVELOPMENT CENTER 602 Robert D. Ray Drive DES MOINES, IOWA 50309 Phone: 515.283.4200 Facsimile: 515.283.4270 Based on the scope of

More information

CITY OF COOPER CITY BUILDING DEPARTMENT

CITY OF COOPER CITY BUILDING DEPARTMENT SITE WORK PERMITS CONTACT COOPER CITY UTILITIES DEPARTMENT 11791 SW 49 Street Cooper City, FL 33330 (954) 434-5519 BROWARD COUNTY IMPACT FEES (Provide a copy of Receipt) CONTRIBUTION IN AID OF CONSTRUCTION

More information

7 NON-STRUCTURAL ELEMENTS

7 NON-STRUCTURAL ELEMENTS Non-Structural Elements 85 7 NON-STRUCTURAL ELEMENTS Edited by Timothy P. McCormick, P.E. 86 Non-Structural Elements Non-Structural Elements 87 NON-STRUCTURAL ELEMENTS CHIMNEYS The first nonstructural

More information

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings Building Safety Department 400-2 nd Street South St. Cloud, MN 56301 (320) 255-7239 A building permit is required for any accessory

More information

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS Please note: This construction plan component list is to be used as a guide to assist you with your project. There may be elements unique to your project not

More information

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC) Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC) Plan Check Submittal Date: Plan Check #: Permit App.# Job Address: Applicant: Phone: ( ) Plan Check Engineer:

More information

Structural Training - Part 1:

Structural Training - Part 1: Structural Training - Part 1: Structural Training Residential Wood-Framed Construction Presented by: City of Santa Clarita Building & Safety Division February, 2014 The information provided in this presentation

More information

SFR SUBMITTAL REQUIREMENTS

SFR SUBMITTAL REQUIREMENTS A. FEES DUE AT TIME OF PERMIT APPLICATION The following non-refundable fees will be collected at the time of application for all residential projects. 1. Building Plan Check Fee B. CODES The City of Oak

More information

DETAIL DRAWINGS. RASTRA is a stay-in-place insulated concrete. form that is structurally strong, energy-efficient,

DETAIL DRAWINGS. RASTRA is a stay-in-place insulated concrete. form that is structurally strong, energy-efficient, DETAIL DRAWINGS RASTRA is a stay-in-place insulated concrete form that is structurally strong, energy-efficient, soundproof, resistant to fire, high wind, mold and rodents and is made from 85% recycled

More information

BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321)

BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321) BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL 32907 Phone: (321) 953-8924 Fax: (321) 953-8925 CUSTOMER SERVICE INFORMATION ON RESIDENTIAL PLAN REVIEW REQUIRED DOCUMENTS MUST BE SUBMITTED AT TIME

More information

BUILDING PERMIT REQUIREMENTS FOR: RESIDENTIAL DECKS CITY OF ESCONDIDO BUILDING DIVISION 201 N. BROADWAY, ESCONDIDO, CA (760)

BUILDING PERMIT REQUIREMENTS FOR: RESIDENTIAL DECKS CITY OF ESCONDIDO BUILDING DIVISION 201 N. BROADWAY, ESCONDIDO, CA (760) BUILDING PERMIT REQUIREMENTS FOR: RESIDENTIAL DECKS INFORMATION GUIDELINE 9 January 2017 CITY OF ESCONDIDO BUILDING DIVISION 201 N. BROADWAY, ESCONDIDO, CA 92025 (760) 839-4647 This information bulletin

More information

UCC Permit Application Procedures

UCC Permit Application Procedures How do I apply for a permit? UCC Permit Application Procedures 1. Please complete the CodeMaster Pan Review Application 2. Please provide the scope of work description and/or construction documents/plans.

More information

05/16/2016 1:36:13 PM

05/16/2016 1:36:13 PM 1223 Mineral Spring Avenue North Providence, RI 02904 STRUCTURAL EXISTING CONDITIONS REPORT Prepared for: Jonathan Levi Architects 266 Beacon Street Boston, Massachusetts, 02116 May 16, 2016Draft WESTPORT,

More information

*FOR RESIDENTIAL PROJECTS, CALL JACK CARNS AT *FOR COMMERCIAL PROJECTS, CALL BRIAN WRUBLE AT

*FOR RESIDENTIAL PROJECTS, CALL JACK CARNS AT *FOR COMMERCIAL PROJECTS, CALL BRIAN WRUBLE AT MOSHANNON VALLEY COUNCIL OF GOVERNMENTS 501 E. MARKET STREET SUITE 7 CLEARFIELD, PA 16830 814-765- 3080 1. ITEMS TO SUBMIT: A. COMPLETED AND SIGNED APPLICATION B. SIGNED PRIOR MUNICIPAL APPROVAL PAGE C.

More information

2003 International Residential Building Code

2003 International Residential Building Code 2003 International Residential Building Code Section R305 Ceiling Height Habitable rooms, hallways, corridors, bathrooms, toilet rooms, laundry rooms and basements shall have a ceiling height of not less

More information

WOOD FRAME SOFT-STORY RETROFIT PROGRAM

WOOD FRAME SOFT-STORY RETROFIT PROGRAM WOOD FRAME SOFT-STORY RETROFIT PROGRAM CACP Presentation March 21, 2018 Soft-Story Retrofit Unit City of Los Angeles Department of Building and Safety 1 How Did This Program Start? 2 California, Health

More information

Florida Building Code 6th Edition (2017) High-Velocity Hurricane Zone Uniform Permit Application Form

Florida Building Code 6th Edition (2017) High-Velocity Hurricane Zone Uniform Permit Application Form Are there Gas Vent Stacks? Yes No Type: Natural LPGX FBC SECTION 1524 HIGH-VELOCITY HURRICANE ZONES REQUIRED OWNER S NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section,

More information

STRUCTURAL DESIGN REQUIREMENTS (SEISMIC PROVISIONS) FOR EXISTING BUILDING CONVERTED TO JOINT LIVING AND WORK QUARTERS

STRUCTURAL DESIGN REQUIREMENTS (SEISMIC PROVISIONS) FOR EXISTING BUILDING CONVERTED TO JOINT LIVING AND WORK QUARTERS INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LABC Chapter 85 Effective: 01-01-2011 DOCUMENT NO.: P/BC 2011-110 Revised: Previously Issued As: P/BC 2002-110 STRUCTURAL DESIGN REQUIREMENTS

More information

Supplemental Concrete Tilt Up Retrofit Plan Check Correction Sheet (2014 LABC)

Supplemental Concrete Tilt Up Retrofit Plan Check Correction Sheet (2014 LABC) Supplemental Concrete Tilt Up Retrofit Plan Check Correction Sheet (2014 LABC) Plan Check Submittal Date: Plan Check / PCIS App #: Job Address: Applicant: P.C. Engineer: (Print first / last name) Phone:

More information

SEISMIC REHABILITATION OF TRADITIONAL UN-REINFORCED MASONRY BUILDINGS IN IRAN

SEISMIC REHABILITATION OF TRADITIONAL UN-REINFORCED MASONRY BUILDINGS IN IRAN COMPDYN 2011 III ECCOMAS Thematic Conference on Computational Methods in Structural Dynamics and Earthquake Engineering M. Papadrakakis, M. Fragiadakis, V. Plevris (eds.) Corfu, Greece, 26 28 May 2011

More information

PLANNING DEPARTMENT. Introduction

PLANNING DEPARTMENT. Introduction COUNTY OF SANTA CRUZ PLANNING DEPARTMENT 701 OCEAN STREET - 4 TH FLOOR, SANTA CRUZ, CA 95060 (831) 454-2580 FAX: (831) 454-2131 TDD: (831) 454-2123 KATHLEEN MOLLOY PREVISICH, PLANNING DIRECTOR EVALUATING

More information

One & Two Family Residential ADDITIONS

One & Two Family Residential ADDITIONS City of St. Petersburg Development Services One & Two Family Residential ADDITIONS (Effective Date: 5/1/03) This checklist is subject to change and improvement at any time. Please determine that you have

More information

SEISMIC STRENGTHENING PROVISIONS FOR UNREINFORCED MASONRY BEARING WALL BUILDINGS

SEISMIC STRENGTHENING PROVISIONS FOR UNREINFORCED MASONRY BEARING WALL BUILDINGS Appendix A: Guidelines for the Seismic Retrofit of Existing Buildings CHAPTER A1 SEISMIC STRENGTHENING PROVISIONS FOR UNREINFORCED MASONRY BEARING WALL BUILDINGS SECTION A101 PURPOSE The purpose of this

More information

McMULLAN & ASSOCIATES, INC.

McMULLAN & ASSOCIATES, INC. McMULLAN & ASSOCIATES, INC. SEISMIC EVALUATION REPORT for the The Castle Building Prepared For Smithsonian Institution Washington, D.C. February 28, 2002 86 Seismic Evaluation G.2 THE CASTLE BUILDING WASHINGTON,

More information

East Lyme Middle School EAST LYME MIDDLE SCHOOL

East Lyme Middle School EAST LYME MIDDLE SCHOOL Description: N EAST LYME MIDDLE SCHOOL The school consists of a multi story building with lower, main and upper level floors. The typical floor framing for the main and upper levels is wide flange steel

More information

INDIANA COUNTY Office of Planning and Development 801 Water Street Indiana, PA (724) Fax (724)

INDIANA COUNTY Office of Planning and Development 801 Water Street Indiana, PA (724) Fax (724) INDIANA COUNTY Office of Planning and Development 801 Water Street Indiana, PA 15701 (724) 465-3870 Fax (724) 465-3151 Permit # Date: FOR OFFICE USE ONLY Building Permit Application ~Residential Stick

More information

Virginia Existing Building Code

Virginia Existing Building Code 2015 Virginia Existing Building Code 2015 Virginia Existing Building Code First Printing: September 2018 ISBN: 978-1-60983-852-2 COPYRIGHT 2018 by INTERNATIONAL CODE COUNCIL, INC. ALL RIGHTS RESERVED.

More information

Attachment A. USG Minimum Design and Construction Requirements for Wood Framed Structures

Attachment A. USG Minimum Design and Construction Requirements for Wood Framed Structures Attachment A USG Minimum Design and Construction Requirements for Wood Framed Structures 1. General Design Criteria 1.1. Per Adopted Georgia State Minimum Standard Building Code 1.2. Minimum Live Loads

More information

One and Two Family Additions

One and Two Family Additions One and Two Family Additions An addition to a house, duplex, garage, or an accessory structure requires a building permit prior to performing any construction. Building Department & Permit Office Mon-Fri

More information

UNREINFORCED MASONRY STRUCTURES -PART I - DEFINITIONS AND PROBLEMS UNDER LATERAL LOADS

UNREINFORCED MASONRY STRUCTURES -PART I - DEFINITIONS AND PROBLEMS UNDER LATERAL LOADS UNREINFORCED MASONRY STRUCTURES -PART I - DEFINITIONS AND PROBLEMS UNDER LATERAL LOADS Some Definitions UnReinforced Masonry (URM): Defined as masonry that contains no reinforcing in it. Masonry Unit:

More information

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS St. Louis County Department of Public Works Division of Code Enforcement HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS This guide is intended to provide the homeowner or contractor with the

More information

2007 SHELTER RETROFIT PROJECT SUBMITTAL Ref: Section (3), Florida Statutes

2007 SHELTER RETROFIT PROJECT SUBMITTAL Ref: Section (3), Florida Statutes Instructions and Clarifications 2007 SHELTER RETROFIT PROJECT SUBMITTAL Ref: Section 252.385(3), Florida Statutes 1. Please review ARC 4496 (found in Appendix C, 2006 Shelter Retrofit Report) before beginning

More information

MAIN FLOOR PLAN. #G x 14 x 8 Shed - Chicken Coop By SDS-CAD Specialized Design Systems 10'-0" 3'-0" 1'-0" 14'-0" 14'-0" 1'-0" 6'-0" 3'-0"

MAIN FLOOR PLAN. #G x 14 x 8 Shed - Chicken Coop By SDS-CAD Specialized Design Systems 10'-0 3'-0 1'-0 14'-0 14'-0 1'-0 6'-0 3'-0 10'-0" BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. BARN TO BE BUILT AS PER LOCAL CODE REQUIREMENTS 14'-0" BWP BWP BWP ABWP 101

More information

APPENDIX 3C DOMINION HOTEL SPECIFICATIONS

APPENDIX 3C DOMINION HOTEL SPECIFICATIONS APPENDIX 3C DOMINION HOTEL SPECIFICATIONS 1. GENERAL 1.1 Refer to Section 2.1 of Schedule 3 [Design and Construction Specifications] regarding compliance with Schedule 3 and this Building Specification.

More information

*FOR RESIDENTIAL PROJECTS, CALL JACK CARNS AT *FOR COMMERCIAL PROJECTS, CALL BRIAN WRUBLE AT

*FOR RESIDENTIAL PROJECTS, CALL JACK CARNS AT *FOR COMMERCIAL PROJECTS, CALL BRIAN WRUBLE AT MOSHANNON VALLEY COUNCIL OF GOVERNMENTS 501 E. MARKET STREET SUITE 7 CLEARFIELD, PA 16830 814-765- 3080 1. ITEMS TO SUBMIT: A. COMPLETED AND SIGNED APPLICATION B. SIGNED PRIOR MUNICIPAL APPROVAL PAGE C.

More information

SECTION PLATE CONNECTED WOOD TRUSSES

SECTION PLATE CONNECTED WOOD TRUSSES SECTION 06173 PLATE CONNECTED WOOD TRUSSES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Shop fabricated wood trusses for roof and floor framing. 2. Bridging, bracing, and anchorage. B. Related Sections:

More information

Building Guide. Colorado Chapter of the International Code Council

Building Guide. Colorado Chapter of the International Code Council 12/29/16 Building uide Colorado Chapter of the International Code Council How to Use this uide Check with your jurisdiction regarding type of submittal (paper or electronic) and for additional requirements.draw

More information

assembly an open space between the roof and ceiling of a building attic balloon frame a joist constructed of steel with bars in the verticle web space

assembly an open space between the roof and ceiling of a building attic balloon frame a joist constructed of steel with bars in the verticle web space assembly two or more interconnected structural components combined to meet a specific function or design requirement attic an open space between the roof and ceiling of a building balloon frame a type

More information

Detailed Assessment of St. Patrick Church, Paraparaumu, NZ. 09 January 2013 MIL Phase 05

Detailed Assessment of St. Patrick Church, Paraparaumu, NZ. 09 January 2013 MIL Phase 05 Detailed Assessment of St. Patrick Church, Paraparaumu, NZ 09 January 2013 MIL120266.00 Phase 05 Report Tracking Miyamoto Impact Ltd. External Review Revision Status Date Prepared by Checked by Review

More information

10. Simplified Rehabilitation

10. Simplified Rehabilitation 10. Simplified Rehabilitation 10.1 Scope This chapter sets forth requirements for the rehabilitation of buildings using the Simplified Rehabilitation Method. Section 10.2 outlines the procedure of the

More information

Minimum Residential Plan Submittal Requirements

Minimum Residential Plan Submittal Requirements Minimum Residential Plan Submittal Requirements BI-24 CRC 2016 In order to make your permit application and the plan review process go as smooth as possible it is important to have a general understanding

More information

CHIMNEYS AND FIREPLACES

CHIMNEYS AND FIREPLACES SECTION R1001 MASONRY FIREPLACES R1001.1 General. Masonry fireplaces shall be constructed in accordance with this section and the applicable provisions of Chapters 3 and 4. R1001.2 Footings and foundations.

More information

Learning from Earthquakes to Improve Rehabilitation of Reinforced Concrete Buildings. James O. Jirsa The University of Texas at Austin

Learning from Earthquakes to Improve Rehabilitation of Reinforced Concrete Buildings. James O. Jirsa The University of Texas at Austin Learning from Earthquakes to Improve Rehabilitation of Reinforced Concrete Buildings James O. Jirsa The University of Texas at Austin Objectives of NATO SfP977231 Seismic evaluation and retrofitting of

More information

SUBMITTAL REQUIREMENTS FOR SINGLE FAMILY DWELLINGS

SUBMITTAL REQUIREMENTS FOR SINGLE FAMILY DWELLINGS SUBMITTAL REQUIREMENTS FOR SINGLE FAMILY DWELLINGS When submitting your application for a Residential project please include the following: 1. Completed Building Permit Application 2. If this is a new

More information

STATE OF NEW HAMPSHIRE DEPARTMENT OF NATURAL AND CULTURAL RESOURCES DIVISION OF PARKS AND RECREATION SKI PATROL HUT PROJECT #: CAP 1804

STATE OF NEW HAMPSHIRE DEPARTMENT OF NATURAL AND CULTURAL RESOURCES DIVISION OF PARKS AND RECREATION SKI PATROL HUT PROJECT #: CAP 1804 STATE OF NEW HAMPSHIRE DEPARTMENT OF NATURAL AND CULTURAL RESOURCES DIVISION OF PARKS AND RECREATION PROJECT #: CAP 1804 FRANCONIA NOTCH STATE PARK FRANCONIA, NEW HAMPSHIRE BID SET 8/4/2017 DRAWING LIST:

More information

CHIMNEYS AND FIREPLACES

CHIMNEYS AND FIREPLACES CHAPTER 10 CHIMNEYS AND FIREPLACES SECTION R1001 MASONRY FIREPLACES R1001.1 General. Masonry fireplaces shall be constructed in accordance with this section and the applicable provisions of Chapters 3

More information

Residential Plan Review for New One and Two Family Dwellings

Residential Plan Review for New One and Two Family Dwellings The following is a list of items that are normally included in a set of construction drawings for one and two family dwellings. The items in bold depict those items that will be reviewed for during the

More information

CITY OF WINTER PARK SETBACK/COVERAGE WORKSHEET GUIDE FOR SINGLE FAMILY ZONING

CITY OF WINTER PARK SETBACK/COVERAGE WORKSHEET GUIDE FOR SINGLE FAMILY ZONING CITY OF WINTER PARK SETBACK/COVERAGE WORKSHEET GUIDE FOR SINGLE FAMILY ZONING See Setback/Coverage Worksheet & Criteria: Pages 1-4 & Accessory Structure Guide Step 1 Step 2 Step 3 Step 4 Step 5 Step 6

More information

Mandatory Wood Frame Soft-story Retrofit Program PERMITTING AND INSPECTION PROCESS GUIDELINES

Mandatory Wood Frame Soft-story Retrofit Program PERMITTING AND INSPECTION PROCESS GUIDELINES INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LAMC Division 93 Effective: 11/22/2015 DOCUMENT NO.: P/BC 2017-136 Revised: 1/11/2017 Previously Issued As: N/A Mandatory Wood Frame Soft-story

More information

4.6 Procedures for Connections

4.6 Procedures for Connections 4.6 Procedures for Connections This section provides Tier 2 evaluation procedures that apply to structural connections: anchorage for normal forces, shear transfer, vertical components, interconnection

More information

SEISMIC RETROFITTING OF EXISTING BUILDINGS

SEISMIC RETROFITTING OF EXISTING BUILDINGS SEISMIC RESILIENT SCHOOL BUILDING CONSTRUCTION OF SCHOOL BUILDINGS FOR SUB-ENGINEER SEISMIC RETROFITTING OF EXISTING BUILDINGS R.K. MALLIK Structural Engineer RND CENTRE PVT. LTD. OBJECTIVE KNOW RETROFITTING

More information

Structural Engineering

Structural Engineering Structural Engineering 4 4.0 TABLE OF CONTENTS 4.1 General Approach 115 Submission Requirements 4.2 Codes and Standards 116 Structural Design of New Buildings 116 Use of Recycled Materials 4.3 Structural

More information

Chapter 2 EARTHQUAKE-RESISTANCE REQUIREMENTS

Chapter 2 EARTHQUAKE-RESISTANCE REQUIREMENTS Chapter 2 EARTHQUAKE-RESISTANCE REQUIREMENTS This chapter explains the International Residential Code s (IRC s) general earthquake-resistance requirements as well as specific IRC requirements concerning

More information

City of Berkeley Framework Guidelines for Soft, Weak or Open Front Building Retrofit Design

City of Berkeley Framework Guidelines for Soft, Weak or Open Front Building Retrofit Design Planning and Development Building & Safety Division City of Berkeley Framework Guidelines for Soft, Weak or Open Front Building Retrofit Design This document presents Guidelines for complying with Chapter

More information

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi STRUCTURAL NOTES MATERIAL STRENGTHS Structural Steel Reinforcing Steel Concrete Masonry Structural Lumber Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel

More information

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC. 320-226.5189 www.101developmentresources.com While every attempt has been made to insure the correctness of this handout, no guarantees are made to its accuracy

More information

CSE Engineering, Inc.

CSE Engineering, Inc. CSE Engineering, Inc. Consulting Structural Engineers December 3, 2012 Mr. Joel Heenan Plans Examiner City of Albany Building Department 333 Broadalbin Street Albany, OR 97321 Re: : Old Church Building

More information

North Shore at Canton Baltimore, MD Beau Menard Technical Report 1

North Shore at Canton Baltimore, MD Beau Menard Technical Report 1 North Shore at Canton Baltimore, MD Beau Menard Technical Report 1 Structural Schneider 10/05/05 Structural Concepts Executive Summary North Shore at Canton is a 4 story town home and parking garage structure

More information