12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS

Size: px
Start display at page:

Download "12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS"

Transcription

1 CONCEALED FASTENED PANELS CFP-12 PANEL INDEX 12 - V0 BASE DETAILS HORIZONTAL JOINT DETAIL PARAPET ROOF DETAIL INSIDE CORNER DETAIL OUTSIDE CORNER DETAIL SOFFIT DETAIL WINDOW JAMB DETAIL WINDOW HEAD DETAIL WINDOW SILL DETAIL REFERENCE SHEETS VO.1 - PANEL PROFILE INFORMATION VA.1 - WINDOW OPENING ISOMETRIC VA.2 - PENETRATION ISOMETRIC VB.1 - PANEL / PANEL OVERLAP SPLICE TRANSITION OPTIONS EACH DETAIL CONSISTS OF TWO DIFFERENT WALL CAVITY ASSEMBLIES; INSULATED AND NON-INSULATED. IE: DETAIL 1 ON THE ELEVATION WILL BE REPRESENTED BY TWO SHEETS 1.1 AND 1.2 ILLUSTRATING EACH RESPECTIVE WALL ASSEMBLY. WALL TYPE 1 & 2 WALL ASSEMBLY DISSEMINATES GENERAL, BEST PRACTICE, RECOMMENDATION FOR USE OF AIR / VAPOR S WITHIN U.S. DEPT. OF ENERGY CLIMATE ZONES

2 CFP-12 - PROFILE 12 - V0.1 INSTALL ITEM NUMBER: CFP-12 NET COVERAGE: 12" (1' 0") MAXIMUM LENGTH: (40 feet) MATERIAL OPTIONS COIL - COATED STEEL COIL - COATED ALUMINUM ANODIZED ALUMINUM FABRICATION OPTIONS STEEL: 18, 20, 22, 24 GAUGE ALUMINUM:.032" -.040" FINISH OPTIONS PAINTING "COIL COATED" HYLAR 5000 / KYNAR 500, MODIFIED POLYESTERS, AND OTHER CUSTOM OR EXOTIC FINISHES. ANODIZING CLEAR, BRONZES, AND VARIOUS OTHER COLORS COIL ANODIZED FOR COLOR CONSISTENCY. NOTES: 1. HEAVIER GAUGES MINIMIZE "OIL CANNING". 2. OIL CANNING IS NOT A CAUSE FOR REJECTION. 3. AN EXTENSIVE SELECTION OF ASSOCIATED PANEL FLASHING AND TRIMS ARE AVAILABLE. 4. CONTACT FIRESTONE BUILDING PRODUCTS FOR UP TO DATE TECHNICAL INFORMATION AND MATERIAL LIMITATIONS. 5. ALL SYSTEMS WITH TESTING MUST BE INSTALLED IN ACCORDANCE WITH THE ASSEMBLY AS TESTED. V0.1

3 CFP-12 - WDW OPENING 12 - VA.1 TYPICAL WINDOW OPENING APPLICATION SEALANTS NOT SHOWN FOR CLARITY METAL STUD WATER RESISTIVE EXTERIOR SHEATHING FURRING OR GIRT "AS REQ'D" BY CODE LOCALIZED FLEXIBLE MEMBRANE METAL FLASHING JAMB TRIM LOCALIZED FLEXIBLE MEMBRANE CFP-12 METAL STUD METAL SILL FLASHING LOCALIZED FLEXIBLE MEMBRANE WATER RESISTIVE VA.1

4 CFP-12 - PENETRATION 12 - VA.2 TYPICAL BEAM PENETRATION APPLICATION SEALANTS NOT SHOWN FOR CLARITY DESIGN PROPER CLEARANCES TO ACCOMMODATE MOVEMENTS METAL STUD FURRING OR GIRT "AS REQ'D" BY CODE EXTERIOR SHEATHING LOCALIZED FLEXIBLE MEMBRANE JAMB TRIM w/foam CLOSURE STRIP METAL FLASHING ATTACHMENT FLANGE STRUCTURAL MEMBER CLOSURE PLATE WET SEAL CUT OUT PERIMETER LOCALIZED FLEXIBLE MEMBRANE METAL STUD EXTERIOR SHEATHING WATER RESISTIVE VA.2

5 CFP-12 - PANEL SPLICE TYPICAL PANEL / PANEL OVERLAP OTHER SPLICE OPTIONS AVAILABLE 12 - VB.1 NOTE: WHEN LAPPING PANEL 'D' OVER 'A' THE LEFT FASTENER FLANGE AND RIGHT HOOK FEATURE AT THE BOTTOM OF THE UPPER PANEL IS NOTCHED BACK TO CLEAR THE TOP OF THE LOWER PANEL. WALL ASSEMBLY EXTERIOR SHEATHING WATER RESISTIVE STARTER STRIP "AS REQ'D" FURRING OR GIRT "AS REQ'D" BY CODE TOP OF LOWER PANEL NON-CURRING BUTYL SEAL 4" LAP MINIMUM NOTCHED UPPER PANEL LOWER PANEL INSTALL INSTALL DIAGRAM VB.1

6 WALL ASSEMBLY TYPE 1 CFP-12 - BASE DETAIL 12 - V1.1 VERTICAL PANELS HAT CHANNEL FASTENERS TYP. 1/8" x 1" PRE FINISHED BASE FLASHING WEEP HOLE LOCALIZED MEMBRANE METAL FLASHING AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS EXTERIOR SHEATHING VAPOR "OPTIONAL" SEALANT PRECAST WEEP TUBE & BAFFLE CONCRETE IMPROVE ENERGY EFFICIENCY WITH PROPER COMPONENT WALL ASSEMBLIES IN MOST REGIONS, EXTERIOR WALLS HAVING INSIDE THE CAVITY SHOULD USE A VAPOR-PERMEABLE MEMBRANE APPLIED ON THE EXTERIOR SIDE OF THE WALL. A VAPOR-PERMEABLE MEMBRANE ALLOWS THE WALL CAVITY TO BREATH AND DRY POTENTIAL MOISTURE CAUSED FROM VAPOR PRESSURE. IN COLDER CLIMATES A NON-PERMEABLE VAPOR MUST BE INSTALLED ON THE INTERIOR SIDE OF THE WALL ASSEMBLY TO MINIMIZE OUTWARD VAPOR PRESSURE CAUSED BY HEATED AND HUMIDIFIED INTERIOR ENVIRONMENTS DURING THE COLD SEASON INTERNATIONAL BUILDING CODE WEATHER PROTECTION: EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A WEATHER-RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND CONSTRUCTED TO PREVENT THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A ON THE SIDE OF THE WALL BEHIND THE EXTERIOR VANEER. PROVIDE MEANS OF DRAINING WATER THAT ENTERS BETWEEN THE EXTERIOR VANEER AND THE WATER-RESISTANT. V1.1

7 WALL ASSEMBLY TYPE 1 VERTICAL PANELS HAT CHANNEL FASTENERS TYP. 1/8" x 1" PRE FINISHED BASE FLASHING CFP-12 - BASE DETAIL LOCALIZED MEMBRANE METAL FLASHING AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS EXTERIOR SHEATHING 12 - V1.1A VAPOR "OPTIONAL" SEALANT PRECAST WEEP TUBE & BAFFLE CONCRETE IMPROVE ENERGY EFFICIENCY WITH PROPER COMPONENT WALL ASSEMBLIES IN MOST REGIONS, EXTERIOR WALLS HAVING INSIDE THE CAVITY SHOULD USE A VAPOR-PERMEABLE MEMBRANE APPLIED ON THE EXTERIOR SIDE OF THE WALL. A VAPOR-PERMEABLE MEMBRANE ALLOWS THE WALL CAVITY TO BREATH AND DRY POTENTIAL MOISTURE CAUSED FROM VAPOR PRESSURE. IN COLDER CLIMATES A NON-PERMEABLE VAPOR MUST BE INSTALLED ON THE INTERIOR SIDE OF THE WALL ASSEMBLY TO MINIMIZE OUTWARD VAPOR PRESSURE CAUSED BY HEATED AND HUMIDIFIED INTERIOR ENVIRONMENTS DURING THE COLD SEASON INTERNATIONAL BUILDING CODE WEATHER PROTECTION: EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A WEATHER-RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND CONSTRUCTED TO PREVENT THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A ON THE SIDE OF THE WALL BEHIND THE EXTERIOR VANEER. PROVIDE MEANS OF DRAINING WATER THAT ENTERS BETWEEN THE EXTERIOR VANEER AND THE WATER-RESISTANT. V1.1 OPTION A

8 WALL ASSEMBLY TYPE 2 CFP-12 - BASE DETAIL 12 - V1.2 VERTICAL PANELS.500 MIN AIR SPACE 12.7 mm AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS 'Z' GIRT LOCALIZED MEMBRANE FASTENERS TYP. 1/8" x 1" EXTERIOR SHEATHING METAL FLASHING VAPOR "OPTIONAL" PRE FINISHED BASE FLASHING WEEP HOLE SEALANT PRECAST WEEP TUBE & BAFFLE CONCRETE V1.2

9 CFP-12 - BASE DETAIL 12 - V1.2A WALL ASSEMBLY TYPE 2 VERTICAL PANELS.500 MIN AIR SPACE 12.7 mm AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS 'Z' GIRT LOCALIZED MEMBRANE FASTENERS TYP. EXTERIOR SHEATHING 1/8" x 1" METAL FLASHING VAPOR "OPTIONAL" PRE FINISHED BASE FLASHING SEALANT PRECAST WEEP TUBE & BAFFLE CONCRETE V1.2 OPTION A

10 WALL ASSEMBLY TYPE 1 CFP-12 - HORIZONTAL JOINT DETAIL 12 - V2.1 FASTENERS TYP. CONT BUTYL SEALANT HAT CHANNEL 4.00" MIN LAP LOCALIZED MEMBRANE AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS VAPOR "OPTIONAL" EXTERIOR SHEATHING V2.1

11 WALL ASSEMBLY TYPE 1 CFP-12 - TRANSITION OPTIONS 12 - V2.1A 2.000" 50.8mm.125" 3.2mm FORMED TRANSITION MOVEMENT JOINT CFP - HORIZONTAL PANELS - STANDARD DETAIL V2.1A

12 CFP-12 - HORIZONTAL JOINT DETAIL 12 - V2.2 WALL ASSEMBLY TYPE 2 VERTICAL UPPER PANEL FASTENERS TYP. BUTYL SEALANT 4.00" MIN LAP LOCALIZED MEMBRANE 'Z' GIRT AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS VAPOR "OPTIONAL" EXTERIOR SHEATHING VERTICAL LOWER PANEL.500 MIN AIR SPACE 12.7 mm V2.2

13 WALL ASSEMBLY TYPE 2 CFP-12 - TRANSITION OPTIONS 12 - V2.2A mm FLR SLAB mm FORMED TRANSITION MOVEMENT JOINT CFP - HORIZONTAL PANELS - STANDARD DETAIL V2.2A

14 WALL ASSEMBLY TYPE 2 CFP-12 - PARAPET ROOF DETAIL 12 - V3.1 PRE FINISHED COPING LOCALIZED MEMBRANE ROOFING MEMBRANE 'Z' FLASHING WOOD BLOCKING SLOT PANEL AT THIS FASTENER TO ALLOW FOR THERMAL EXPANSION SEAL W/ SEAL or TAPE EDGES AND ALL PENETRATIONS AND PERALL PENETRATIONS MANUF. RECOMMENDATIONS PER MANUF. RECOMMENDATIONS LOCALIZED MEMBRANE EXTERIOR SHEATHING HAT CHANNEL FIRE RATED PLYWOOD VAPOR "OPTIONAL" V3.1

15 WALL ASSEMBLY TYPE 2 CFP-12 - PARAPET ROOF DETAIL 12 - V3.2 ROOFING MEMBRANE WOOD BLOCKING PRE FINISHED COPING LOCALIZED MEMBRANE 'Z' FLASHING LOCALIZED MEMBRANE AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS SLOT PANEL AT THIS FASTENER TO ALLOW FOR THERMAL EXPANSION SEAL W/ VERTICAL PANELS HAT CHANNEL EXTERIOR SHEATHING RATED PLYWOOD VAPOR "OPTIONAL".500 MIN AIR SPACE 12.7 mm V3.2

16 WALL ASSEMBLY TYPE 1 CFP-12 - INSIDE CORNER DETAIL 12 - V4.1 VAPOR "OPTIONAL" " 88.9mm PRE FINISHED INSIDE CORNER HAT CHANNEL BUTYL / HOTMELT SEALANT (FACTORY OR FIELD APPLIED) INTERIOR DRYWALL EXTERIOR SHEATHING VERTICAL PANELS V4.1

17 WALL ASSEMBLY TYPE 2 CFP-12 - INSIDE CORNER DETAIL 12 - V " 88.9mm PRE FINISHED INSIDE CORNER BUTYL / HOTMELT SEALANT (FACTORY OR FIELD APPLIED) EXTERIOR SHEATHING VERTICAL PANELS 'Z' GIRT.500 MIN AIR SPACE 12.7 mm V4.2

18 WALL ASSEMBLY TYPE 1 CFP-12 - OUTSIDE CORNER DETAIL 12 - V5.1 EXTERIOR SHEATHING VERTICAL PANELS VAPOR "OPTIONAL" HAT CHANNEL BUTYL / HOTMELT SEALANT (FACTORY OR FIELD APPLIED) PRE FINISHED OUTSIDE CORNER 4.750" 120.7mm VERTICAL PANELS V5.1

19 WALL ASSEMBLY TYPE 2 CFP-12 - OUTSIDE CORNER DETAIL 12 - V5.2 EXTERIOR SHEATHING VAPOR "OPTIONAL" VERTICAL PANELS FASTENERS TYP. 'Z' GIRT BUTYL / HOTMELT SEALANT (FACTORY OR FIELD APPLIED).500 MIN AIR SPACE 12.7 mm PRE FINISHED INSIDE CORNER 6.500" 165.1mm V5.2

20 WALL ASSEMBLY TYPE 1 AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS CFP-12 - SOFFIT DETAIL 12 - V6.1 VAPOR "OPTIONAL" FASTENERS TYP. LOCALIZED MEMBRANE HAT CHANNEL PRE FINISHED BASE FLASHING WEEP HOLE PRE FINISHED SOFFIT FLASHING EXTERIOR SHEATHING V6.1

21 WALL ASSEMBLY TYPE 2 CFP-12 - SOFFIT DETAIL 12 - V MIN AIR SPACE 12.7 mm AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS LOCALIZED MEMBRANE FASTENERS TYP. VAPOR "OPTIONAL" 1/8" x 1" 'Z' GIRT PRE FINISHED BASE FLASHING WEEP HOLE PRE FINISHED BASE FLASHING EXTERIOR SHEATHING V6.2

22 WALL ASSEMBLY TYPE 1 CFP-12 - WINDOW JAMB DETAIL 12 - V7.1 EXTERIOR SHEATHING VAPOR "OPTIONAL" LOCALIZED MEMBRANE WINDOW/DOOR SYSTEM 1/8" x 1" PREFINISHED JAMB TRIM BUTYL / HOTMELT SEALANT (FACTORY OR FIELD APPLIED) 3.000" 76.2mm BUTYL HAT CHANNEL V7.1

23 WALL ASSEMBLY TYPE 2 CFP-12 - WINDOW JAMB DETAIL 12 - V7.2 EXTERIOR SHEATHING VAPOR "OPTIONAL" LOCALIZED MEMBRANE WINDOW/DOOR SYSTEM PREFINISHED JAMB TRIM 1/8" x 1" 'Z' GIRT.500 MIN AIR SPACE 12.7 mm BUTYL / HOTMELT SEALANT (FACTORY OR FIELD APPLIED) 3.000" 76.2mm V7.2

24 WALL ASSEMBLY TYPE 1 CFP-12 - WINDOW HEAD DETAIL 12 - V8.1 EXTERIOR SHEATHING LOCALIZED MEMBRANE HAT CHANNEL AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS FASTENERS TYP. PREFINISHED 'J' TRIM WEEP HOLE SEALANT PREFINISHED FLASHING WEEP TUBE & BAFFLE WINDOW/DOOR SYSTEM VAPOR "OPTIONAL" LOCALIZED MEMBRANE V8.1

25 WALL ASSEMBLY TYPE 1 CFP-12 - WINDOW HEAD DETAIL 12 - V8.1A EXTERIOR SHEATHING LOCALIZED MEMBRANE HAT CHANNEL AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS VAPOR "OPTIONAL".125" PREFINISHED FLASHING WINDOW/DOOR SYSTEM LOCALIZED MEMBRANE V8.1 OPTION A

26 WALL ASSEMBLY TYPE 2 CFP-12 - WINDOW HEAD DETAIL 12 - V MIN AIR SPACE 12.7 mm 'Z' GIRT LOCALIZED MEMBRANE AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS FASTENERS TYP. 1/8" x 1" VAPOR "OPTIONAL" PRE FINISHED BASE FLASHING WEEP TUBE & BAFFLE EXTERIOR SHEATHING WEEP HOLE SEALANT PREFINISHED FLASHING WINDOW/DOOR SYSTEM LOCALIZED MEMBRANE V8.2

27 WALL ASSEMBLY TYPE 2 'Z' GIRT CFP-12 - WINDOW HEAD DETAIL.500 MIN AIR SPACE 12.7 mm 12 - V8.2A AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS LOCALIZED MEMBRANE FASTENERS TYP. 1/8" x 1".125" VAPOR "OPTIONAL" EXTERIOR SHEATHING PREFINISHED FLASHING WINDOW/DOOR SYSTEM LOCALIZED MEMBRANE V8.2 OPTION A

28 WALL ASSEMBLY TYPE 1 CFP-12 - WINDOW SILL DETAIL 12 - V9.1 WINDOW/DOOR SYSTEM SILL TRIM SILL TRIM CLIP (BY SILL TRIM INSTALLER) FASTENERS TYP. HAT CHANNEL LOCALIZED MEMBRANE AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS VAPOR "OPTIONAL" EXTERIOR SHEATHING V9.1

29 WALL ASSEMBLY TYPE 2 CFP-12 - WINDOW SILL DETAIL 12 - V9.2 WINDOW/DOOR SYSTEM SILL TRIM SILL TRIM CLIP (BY SILL TRIM INSTALLER) LOCALIZED MEMBRANE 'Z ' GIRT VAPOR "OPTIONAL" AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS EXTERIOR SHEATHING.500 MIN AIR SPACE 12.7 mm V9.2

30 WALL ASSEMBLY TYPE 1 CFP-12 - VERTICAL TRANSITIONS 12 - V10.1 VHB TAPE 2.000" 50.8mm 1.000" 25.4mm 5.000" 127.0mm 2.000" 50.8mm 5" FORMED TRANSITION STRIP w/ REVEAL - STD. DETAIL.563" 14.3mm 3.000" 76.2mm 3" FORMED TRANSITION STRIP w/ SEAL JOINT CFP - - OPTION 'A' V10.1

31 WALL ASSEMBLY TYPE 1 CFP-12 - VERTICAL TRANSITIONS 12 - V10.2 VHB TAPE 5.000" 127.0mm 5" FORMED TRANSITION STRIP w/ FLAT FACE CFP - - OPTION 'B' V10.2

FACE CFP - HORIZONTAL PANELS - OPTION 'B'

FACE CFP - HORIZONTAL PANELS - OPTION 'B' - Vertical Transitions 12F - H10.3 VHB TAPE 5.000" 127.0mm 5" FORMED TRANSITION STRIP w/ FLAT FACE CFP - - OPTION 'B' H10.3 CONCEALED FASTENED Panel Index 12F - H0 BASE DETAILS JOINT DETAIL PARAPET ROOF

More information

MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA

MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA Existing Yard Security Light Proposed Rooftop Mechanical Screening (Slate Gray) Proposed 3 x4 x 4 x4 Windows Metal Awning Existing Doors Metal Siding(Slate Gray) Trim (Matte Black) 14 14 Proposed Addition

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 6 7 8 10 26 19 20 14 15 22 SOFFIT OUTSIDE CORNER INSIDE CORNER 23 25 24 25 5 27 28 29 16 11 OPENING 17 18 END WALL 21 12 13 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CSH-01 CSH-02 CSH-03 CSH-04 CSH-05

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 6 7 8 10 OUTSIDE CORNER 19 20 4 5 11 21 22 15 16 13 12 OPENING 14 SOFFIT 18 END WALL 17 INSIDE CORNER 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CCV-01 CCV-02 CCV-03 CCV-04 CCV-05 CCV-06 CCV-07 CCV-08

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 8 4 5 6 9 16 10 15 11 SOFFIT 19 OUTSIDE CORNER 20 21 INSIDE CORNER 3 22 23 12 13 OPENING 14 END WALL 17 18 7 4 5 6 ELEVATION FOR DETAIL REFERENCE ONLY CSV-01 CSV-02 CSV-03 CSV-04 CSV-05 CSV-06 CSV-07 CSV-08

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 5 6 8 9 1 10 15 SOFFIT OUTSIDE CORNER 16 18 19 12 OPENING 11 END WALL INSIDE CORNER 17 1 7 5 6 ELEVATION FOR DETAIL REFERENCE ONLY IWV-01 IWV-02 IWV-0 IWV-0 IWV-05 IWV-06 IWV-07 IWV-08 IWV-09 IWV-10 INDEX

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 4 5 6 8 18 13 10 15 SOFFIT OUTSIDE CORNER INSIDE CORNER 16 17 3 19 20 11 9 OPENING 12 END WALL 14 7 4 5 6 ELEVATION FOR DETAIL REFERENCE ONLY EH-01 INDEX EH-02 STANDARD PANEL OFFERING EH-03 SIDE LAP DETAILS

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY #smr_elev 5b SEC 2 8i SEC 2 33 SEC 4 1a SEC 2 37 SEC 4 36 SEC 4 35 SEC 4 SOFFIT FRONT 6d SEC 2 7a SEC 2 SOFFIT REAR INSIDE CORNER (REAR) OUTSIDE CORNER (FRONT) 10a SEC 2 9b SEC 2 4e SEC 2 ELEVATION FOR

More information

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET KPH-DS-01-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV KPH-BS-04-MTLV KPH-OC-01-MTLV KPH-IC-01-MTLV KPH-SF-01-MTLV KPH-SF-02-MTLV

More information

Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing

Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing EXTERIOR BASE DETAIL (FLUSH) EXTERIOR BASE DETAIL (OVERHANG) Base Trim with Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint Sealant Marriage Bead to Vertical Panel Joint Above and Below Z Flashing

More information

COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INDEX INSTALLATION SEQUENCE INSTALLATION SEQUENCE INSTALLATION SEQUENCE

COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INDEX INSTALLATION SEQUENCE INSTALLATION SEQUENCE INSTALLATION SEQUENCE COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INSTALLATION SEQUENCE TT 5-8 TT- 13 INSTALLATION SEQUENCE INSTALLATION SEQUENCE TT- 4 TT-10 TT-14 TT-12 TT- 3 TT-11 TT-10 TT- 9 TT-11 TT- 2 INDEX (TT- 0): SYSTEM

More information

WeatherSmart Air Barrier Installation Guide

WeatherSmart Air Barrier Installation Guide WeatherSmart Air Barrier Installation Guide 1 The intent of this document is to provide a guide for the installation of WeatherSmart as both a Weather Resistive Barrier (W.R.B.) and an Air Barrier Material

More information

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights 1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights These 1 Exam Prep tabs are based on the 2012 Sheet Metal and Air Conditioning Contractors' National Association, Inc., seventh edition.

More information

Ameriplate. Rain Screen Wall System

Ameriplate. Rain Screen Wall System Ameriplate Rain Screen Wall System Efficiency and fascinating free-floating effects are hallmarks of Metalwërks Ameriplate wall systems. With Ameriplate, the cut edges of the face plate material are the

More information

7.0 - EXAMPLE DETAILS

7.0 - EXAMPLE DETAILS 7.0 - EXAMPLE DETAILS The drawings represented herein are believed to be accurate and conforming to current design and construction practices. However, the drawings should be used as a reference guide

More information

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 07 4243 - PART 1 GENERAL 1.01 SECTION INCLUDES A. Composite wall panel system consisting of aluminum-faced composite panels in a rainscreen application as part of the assembly described below.

More information

ENVELOPE The Ultimate In Performance In A Dry-Joint System RAINSCREEN (RS) SYSTEM TECHNICAL MANUAL

ENVELOPE The Ultimate In Performance In A Dry-Joint System RAINSCREEN (RS) SYSTEM TECHNICAL MANUAL ENVELOPE 2000 RAINSCREEN (RS) SYSTEM The Ultimate In Performance In A Dry-Joint System TECHNICAL MANUAL System Assembly Substrate Layouts CAD Sections/Details Physical Properties Performance Properties

More information

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING INSTALLING WATER-RESISTIVE BARRIERS & FLASHING IN A TWO-LAYER STUCCO APPLICATION Fortifiber Building Systems Group provides this guide to assist installers by demonstrating a two-layer installation of

More information

Wall Assembly - ACM Metal Panel at Steel Stud Framing SCALE: 3" = 1'-0"

Wall Assembly - ACM Metal Panel at Steel Stud Framing SCALE: 3 = 1'-0 Thermafiber "RainBarrier 45" Nvelope "NH2" Bracket Adapter Nvelope Wall Bracket (90mm or as Req'd) ACM Metal Panel System Metal Panel Extrusion per ACM Manufactuer 1 2 " Self-Drilling Stainless Steel Fastener

More information

Prestige Series. (Horizontal Install.) Installation Guide

Prestige Series. (Horizontal Install.) Installation Guide Prestige Series (Horizontal Install.) Installation Guide Prestige Series (Horizontal Install.) Installation Guide - Table of Contents - Section Page General Notes..............................................................

More information

KS SERIES - VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV

More information

Omniplate Barrier Wall System

Omniplate Barrier Wall System is an economical barrier wall system with visible caulk joints at all horizontal and vertical panel joints. As a barrier wall, serves as the primary weather barrier for the building envelope. It can be

More information

Architectural Wall Products Guide Specifications

Architectural Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is

More information

Ice Rink Renovation & New Clubhouse

Ice Rink Renovation & New Clubhouse SECTION 074243- METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

TYPICAL ROOF CONDITION LAYOUT

TYPICAL ROOF CONDITION LAYOUT FIXED POINTS TYPICAL ROOF CONDITION LAYOUT 15 17 9 16 29 12 14 11 3 7 35 20 6 23 30 31 24 13 18 Typical Roof Condition Layout... 1 Low Eave Isometric View - Fixed/ Floating... 2 Low Eave Section - Fixed/

More information

GAF EnergyGuard Polyiso Wall Sheathing

GAF EnergyGuard Polyiso Wall Sheathing From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include:

More information

CONTOUR CORRUGATED PANEL

CONTOUR CORRUGATED PANEL CONTOUR CORRUGATED PANEL Table of Contents SECTION PAGE Designer Notes............................................... 1 Panel Net Coverage / Fasteners.................................... 2 ROOF Details

More information

Ameriplate. Rain Screen Wall System

Ameriplate. Rain Screen Wall System Ameriplate Rain Screen Wall System Efficiency and fascinating free-floating effects are hallmarks of Metalwërks Ameriplate wall systems. With Ameriplate, the cut edges of the face plate material are the

More information

SECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION. SECTION 074213 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting

More information

KARRIER PANEL - BRICK

KARRIER PANEL - BRICK KPH-DS-01-BRICK KPH-PJ-01-BRICK KPH-PJ-02-BRICK KPH-PJ-03-BRICK KPH-BS-01-BRICK KPH-BS-02-BRICK KPH-BS-03-BRICK KPH-OC-01-BRICK KPH-FO-01-BRICK KPH-FO-02-BRICK KPH-FO-03-BRICK KPH-FO-04-BRICK KPH-FO-05-BRICK

More information

Student Services & Classroom Addition

Student Services & Classroom Addition SECTION 074243 - METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

National Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 Section [ ].

National Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 Section [ ]. National Master Specification (NMS) Section 07 21 16 BLANKET INSULATION Publisher: Spex.ca Page 1 Approved: 2014-12-31 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section [ ]. 1.2 REFERENCES.1 CSA Group.1

More information

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying perforated

More information

TW-12. (Horizontal Installation) Installation Guide

TW-12. (Horizontal Installation) Installation Guide TW-12 (Horizontal Installation) Installation Guide TW-12 (Horizontal Install.) Installation Guide - Table of Contents - Section Page General Notes..............................................................

More information

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM RAINSCREEN (H&J) SYSTEM INSTALLATION DATA & DETAILS Omnis Panels, Inc. Architectural Building Panels 22 East Chicago Avenue Suite 210 Naperville, Illinois 60540 (800) 450-6099 (630) 355-4040 Fax: (630)

More information

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM RAINSCREEN (H&J) SYSTEM INSTALLATION DATA & DETAILS Omnis Panels, Inc. Architectural Building Panels 22 East Chicago Avenue Suite 210 Naperville, Illinois 60540 (800) 450-6099 (630) 355-4040 Fax: (630)

More information

EMBRY RIDDLE PRESCOTT SECTION METAL COMPOSITE MATERIAL WALL PANELS

EMBRY RIDDLE PRESCOTT SECTION METAL COMPOSITE MATERIAL WALL PANELS SECTION 074213.23 - WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

CENTRIA Concept Series Metal Wall Panels ZINC

CENTRIA Concept Series Metal Wall Panels ZINC CENTRIA Concept Series Metal Wall Panels ZINC CENTRIA Concept Series Metal Wall Panels are a versatile design choice for wall cladding panels. They are manufactured with a variety of profiles and five

More information

typical section 1:50 Important:

typical section 1:50 Important: 00 Typical ventilated facade installation mounted with top hat channels onto external walls, awning soffit and fascia. 00 Wall panels are shown in varying heights, having open joints for ventilation of

More information

Ultra Wall System. CAD Detail Sets

Ultra Wall System. CAD Detail Sets Ultra Wall System CAD Detail Sets Contents Page UWS-CM CAVITYMATE Ultra Contents 1-0 FOR: Details continuing on 1-1 thru 1-17 Cavity cut XPS board to fit between ladder tie masonry ties in CMU walls UWS-SL

More information

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology FLASHING DETAILS FOR CONCRETE MASONRY WALLS TEK 19-5A Water Penetration Resistance

More information

Proper Installation of Insulated Metal Wall Panels

Proper Installation of Insulated Metal Wall Panels Proper Installation of Insulated Metal Wall Panels Insulated metal panels (IMPs) are an ideal cladding solution for pre-engineered metal buildings. They are available in lengths up to 50, and may also

More information

ENVELOPE The Ultimate In Performance In A Wet-Sealed System ROUT & RETURN (RR) SYSTEM TECHNICAL MANUAL

ENVELOPE The Ultimate In Performance In A Wet-Sealed System ROUT & RETURN (RR) SYSTEM TECHNICAL MANUAL ENVELOPE 2000 ROUT & RETURN (RR) SYSTEM The Ultimate In Performance In A Wet-Sealed System TECHNICAL MANUAL System Assembly Substrate Layouts CAD Sections/Details Physical Properties Performance Properties

More information

Arcwall. Rain Screen Wall System

Arcwall. Rain Screen Wall System Rain Screen Wall System is an economical drained and back-ventilated rain screen system for both walls and soffits manufactured from formed aluminum or stainless plate. The system combines excellent performance

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 074213 - INSULATED METAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

PRODUCT DATA ECMS EC-200 SYSTEM COMPOSITE WALL PANEL 8/25/2016

PRODUCT DATA ECMS EC-200 SYSTEM COMPOSITE WALL PANEL 8/25/2016 8/25/2016 PRODUCT DATA ECMS EC-200 SYSTEM COMPOSITE WALL PANEL East Coast Metal Systems, Inc 407 53 rd Street P.O. Box 217 Bellaire, OH 43906 P: F: (740) 671-8760 SYSTEM The Pressure Equalized Rain Screen

More information

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS Per: 2006 B.C.B.C. Part 9 DISCLAIMER: THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME

More information

Metafor Panel System Installation Guide

Metafor Panel System Installation Guide Installation Guide innovative cladding design solutions Product Description Universal Flashing Kit Supplemental Guide for VM Pro-Zinc Training To enroll in a VM PRO-ZINC Training Course contact: UMICORE

More information

SECTION ROOF SPECIALTIES

SECTION ROOF SPECIALTIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

BUILDING ENVELOPE DESIGN GUIDELINES APPENDIX 3

BUILDING ENVELOPE DESIGN GUIDELINES APPENDIX 3 PART 1 GENERAL BUILDING ENVELOPE DESIGN GUIDELINES 1.01 INTRODUCTION A. This is a guideline on the Owner s minimum standards for: 1. Masonry Division 04 2. Copings Division 04 or 07 3. Cavity wall flashings

More information

Prestige Series 12. Installation guide

Prestige Series 12. Installation guide Prestige Series 12 Installation guide PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS Section Page Notes to Designer/User.................... 2 Panel Options............................. 3 Panel Details..............................

More information

Stone and Masonry Veneer

Stone and Masonry Veneer Stone and Masonry Veneer R703.7 Stone and masonry veneer, general. Stone and masonry veneer shall be installed in accordance with this chapter, Table R703.4 and Figure R703.7. These veneers installed over

More information

900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900

900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900 CS-PJ-01-900 CS-DS-01-900 CS-PJ-02-900 CS-EL-01-900 CS-EL-02-900 CS-EL-03-900 CS-EL-04-900 CS-RD-01-900 CS-RD-02-900 CS-RD-03-900 CS-EV-01A-900 CS-EV-01B-900 CS-EV-02A-900 CS-EV-02B-900 CS-EV-03A-900 CS-EV-03B-900

More information

The better way to build TM. Installation Manual NAILBASE PANELS

The better way to build TM. Installation Manual NAILBASE PANELS The better way to build TM Installation Manual PANELS November 2018 SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................

More information

Siding and Soffit Installation Guidelines

Siding and Soffit Installation Guidelines Siding and Soffit Installation Guidelines email web phone 07 46 16 Longboard Siding & Soffit INTRODUCTION INSTALLATION GUIDELINES NOTE: These instructions are prepared for persons experienced in the field

More information

DIVISION 7: MOISTURE PROTECTION SECTION 07417: INSULATED METAL PANELS

DIVISION 7: MOISTURE PROTECTION SECTION 07417: INSULATED METAL PANELS DIVISION 7: MOISTURE PROTECTION SECTION 07417: INSULATED METAL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE: SECTION 07651 FLEXIBLE COPPER SHEET FLASHINGS Advanced Building Products, Inc. manufacturer many types of flexible copper sheet flashings. Due to their ductility, high tensile strength, and resistance

More information

CR# August 20, 2015

CR# August 20, 2015 SECTION 07 40 00 - METAL ROOF AND WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Factory-formed and field-assembled, standing-seam metal roof panels. 2. Factory-formed and field-assembled,

More information

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions Specifiers: Click on the icon in the WD toolbar to reveal detailed instructions (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying metal wall panels

More information

Siding and Soffit Installation Guidelines

Siding and Soffit Installation Guidelines Siding and Soffit Installation Guidelines email web phone 07 46 16 Longboard Siding & Soffit INTRODUCTION INSTALLATION GUIDELINES NOTE: These instructions are prepared for persons experienced in the field

More information

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1 FIRESTOP JOINT SPRAY CFS-SP WB SILICONE JOINT SPRAY CFS-SP SIL F-RATING 2-HR. 2-HR. T-RATING -HR. -HR. APPLICATION THICKNESS PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table /8" WET FILM (/6"

More information

SECTION METAL COMPOSITE MATERIAL WALL PANELS

SECTION METAL COMPOSITE MATERIAL WALL PANELS SECTION 074213.23 - METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 092216 - NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Product Brochure. Masonry Drainage and Ventilation Products

Product Brochure. Masonry Drainage and Ventilation Products Product Brochure Masonry Drainage and Ventilation Products Every building professional who works with masonry knows the #1 reason masonry buildings fail is moisture trapped behind the veneer. Professionals

More information

DIVISION 7 THERMAL AND MOISTURE PROTECTION

DIVISION 7 THERMAL AND MOISTURE PROTECTION DIVISION 7 THERMAL AND MOISTURE PROTECTION UCSC Campus Standards Handbook Waterproofing Standards 07100 1 SECTION 07100: WATERPROOFING STANDARDS A. Guarantee 1. Provide a guarantee on Contractor's letterhead

More information

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866) TECHNICAL NOTE On Cold-Formed Steel Construction $5.00 Light Gauge Steel Engineers Association Washington, D.C. 20005 Toll Free (866) 465-4732 www.lgsea.com DESIGN OF BY-PASS SLIP CONNECTORS IN COLD-FORMED

More information

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer... SECTION DIRECTORY General Information Introduction... V250-ID-886 Installation Accessories and Applications... V250-ID-886 Typical Sealant Placement Details... V250-ID-887 Fin Installation Details Wood

More information

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System CENTRIA Intercept Entyre is a unique modular metal wall system designed, available from a reliable national manufacturer and supported

More information

Detail Booklet StoTherm ci XPS

Detail Booklet StoTherm ci XPS Detail Booklet Series 53sxx Steel Frame Construction February 2017 professional, general contractor or builder They should be installed in accordance with those specifications and Sto s instructions Sto

More information

200 / 300 SERIES PANELS COLD STORAGE

200 / 300 SERIES PANELS COLD STORAGE CS-DS-01-200/300 DISCLAIMER CS-CD-01-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CS-CD-02-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CONTINUED CI-PP-01-200 PANEL PROFILES 200 SERIES

More information

University of Colorado Colorado Springs. National Cybersecurity Center Roof Replacement Package CSNA Project Number

University of Colorado Colorado Springs. National Cybersecurity Center Roof Replacement Package CSNA Project Number ADDENDUM NUMBER 0 TO PROJECT MANUAL AND DRAWINGS August 9, 6 OWNER: ARCHITECT: University of Colorado Colorado Springs CSNA Architects PROJECT: National Cybersecurity Center Roof Replacement Package CSNA

More information

WrapShield SA Brick Tie Penetration

WrapShield SA Brick Tie Penetration Brick Tie Penetration Outboard Vapor - Pemeable Insulation WrapShield SA Self-adhered WRB/AB field membrane Brick Tie must be Flush and compressed against Membrane with no prong penetrations Gasketed Fastener

More information

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6 DECEMBER, 2016 Page 1 of 6 1 GENERAL 1.01 RELATED SECTIONS.1 Section 01 33 00 - Submittal Procedures..2 Section 07 21 16 - Batt and Blanket Insulation..3 Section 07 92 10 - Sealants..4 Section 09 91 00

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used

More information

C. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope.

C. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope. SECTION 08 4519 - POLYCARBONATE WALL SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. Exterior System: The design, manufacture and installation of an aluminum and polycarbonate insulating translucent system.

More information

How do you install yours?

How do you install yours? How do you install yours? Darrell Paul Qualistat Building Performance Consultants CSA 440 Just about adding Peel & Stick? 1 Window and door problems Photos / videos Video available for viewing at INSTAGRAM

More information

Commercial Flashing Details

Commercial Flashing Details This technical note illustrates many of the most common flashing details for commercial buildings. The purpose for flashing is to direct moisture to the exterior and in so doing, prevent moisture from

More information

RESIDENTIAL INSULATED SHEATHING COMFORTBOARD. Installation Guide

RESIDENTIAL INSULATED SHEATHING COMFORTBOARD. Installation Guide RESIDENTIAL INSULATED SHEATHING TM COMFORTBOARD 80 Installation Guide Table of Contents Introduction How to Use this Guide...1 Split-Insulation Wall Assembly...2 Insulation... 3 Nominal and Effective R-Values

More information

Exterior Stucco and Siding Installation

Exterior Stucco and Siding Installation Exterior Stucco and Siding Installation CITY OF NEWARK, CALIFORNIA BUILDING INSPECTION DIVISION 37101 Newark Boulevard, Newark, CA 94560-3796 510-578-4261 Fax 510-578-4307 e-mail: building.inspection@newark.org

More information

LUX Specifications. Section S - Preformed Steel Siding

LUX Specifications. Section S - Preformed Steel Siding Part 1 General.1 System-1: Installation over building paper or air barrier membrane, on exterior grade gypsum board or exterior grade wood sheathing. 1.2 RELATED SECTIONS.1 Section 01 11 00 Summary of

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL WALL PANELS This Guide Specification

More information

DIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING

DIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING DIVISION 5 METALS SECTION 05 40 00 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION METAL ROOF AND SOFFIT PANELS

SECTION METAL ROOF AND SOFFIT PANELS Metal Panel Systems, Inc. 11506 Reading Road Cincinnati, Ohio 45241-2512 Telephone: 800-554-6126 or 513-554-6120 Fax: 513-554-6121 www.metalpanelsystems.com info@metalpanelsystems.com Specifications for

More information

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels.

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels. 1/11 SECTION 074213.23 - ALUMINUM COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section includes aluminum composite material wall panels. 1.2 PRE-INSTALLATION MEETINGS A. Pre-installation

More information

Architectural Roof Products Guide Specifications

Architectural Roof Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification

More information

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

A Closer Look Inspection Service 2015 IECC Residential DFW area handout 103.2 Information required on construction documents 1. Designation of the Thermal Building Envelope on the plans 2. Insulation Material and their R Value 3. Fenestration U and SHGC values 4. Area weighted

More information

Fascia Systems. oofing 7.1

Fascia Systems. oofing 7.1 Systems oofing 7.1 TremLock TM A Pre-engineered, Non-Penetrating Metal Edge System oofing TremLock TM Pre-engineered, Non-penetrating Metal Edge System The TremLock is a pre-engineered, non-penetrating

More information

SECTION GYPSUM BOARD & SHEATHING SYSTEMS

SECTION GYPSUM BOARD & SHEATHING SYSTEMS PART 1!GENERAL! 1.01! SECTION INCLUDES SECTION 09260 GYPSUM BOARD & SHEATHING SYSTEMS! Metal stud wall framing. Metal channel ceiling framing.! Gypsum board.! Sheathing.! Taped and sanded joint treatment.!

More information

Arcwall. Rain Screen Wall System

Arcwall. Rain Screen Wall System Arcwall Rain Screen Wall System Arcwall is an economical drained and back-ventilated rain screen system for both walls and soffits manufactured from formed aluminum or stainless plate. The system combines

More information

HouseWrap Applications System R-Value: R-4.17 Horizontal Heat Flow Only

HouseWrap Applications System R-Value: R-4.17 Horizontal Heat Flow Only Installation Method (Existing Walls) 1. ESP Low-E Housewrap is installed over exterior wall sheathing, make sure reflective side faces out: foil flange faces down. 2. Determine width of ESP Low-E HouseWrap

More information

PRE-ENGINEERED METAL BUILDING SYSTEM

PRE-ENGINEERED METAL BUILDING SYSTEM PRE-ENGINEERED METAL BUILDING SYSTEM PART 1 GENERAL 1.1 SUMMARY A. The building shall include all primary and secondary structural framing members, connection bolts, roof and wall covering, flashing, gutter,

More information

CENTRIA FORMABOND II Metal Composite Wall System

CENTRIA FORMABOND II Metal Composite Wall System CENTRIA FORMABOND II Metal Composite Wall System CENTRIA FormaBond II is the only true metal composite panel wall system designed, manufactured and fabricated by a single, reliable national manufacturer

More information

SUSPENSION REQUIREMENTS SEE DETAIL B1.2 TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET 2" MODULE. SPECIFICATIONS (unless noted otherwise)

SUSPENSION REQUIREMENTS SEE DETAIL B1.2 TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET 2 MODULE. SPECIFICATIONS (unless noted otherwise) 1 5 32 " 2" 27 32 " REQUIRED FOR 1 1 4 " 113 32 " 2 21 32 " SEE DETAIL B1.2 CARRIER SPAN VARIES DEPENDING ON DESIGN WIND PRESSURE 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL B1.2 12

More information

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS SECTION 07 4213.25 PART 1- GENERAL 1.01 SECTION INCLUDES A. Copper metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.

More information

Building Construction and Water Intrusion

Building Construction and Water Intrusion Building Construction and Water Intrusion RAY CHOY-MARSHALL GOVAN ASSOCIATES an architectural corporation ray_choy-marshall@sbcglobal.net 2930 camino diablo, suite 210, walnut creek, ca 94597 2004 Design

More information

ATTACHMENT 2 DRC Page 1 of 13

ATTACHMENT 2 DRC Page 1 of 13 Page 1 of 13 CLEAR GLASS 7' - 6" SPANDREL GLASS CLEAR GLASS SOLID PHENOLIC PANEL MEAT PREP 206 EMPLOYEE LOCKERS 181 VARIES 8' - 1" 2' - 9" 3' - 1" 2' - 8" 2' - 5" 0'-0" 19' - 6" SECTION @ SOUTH WALL Scale:

More information

FirstEnergy Program Overview

FirstEnergy Program Overview FirstEnergy Program Overview Builder incentives $400 per unit + $0.10/kWh in projected savings Eligibility Located in service area of a FirstEnergy Utility Certificate of Occupancy Dates: FirstEnergy Ohio

More information

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions...3 Fastener Placement...4 Fastener Selection...5

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions...3 Fastener Placement...4 Fastener Selection...5 Table of Contents Section Page Notes to Designer/User...................1-2 Map of Typical Roof Conditions..............3 Fastener Placement........................4 Fastener Selection.........................5

More information

DuPont Tyvek Wall Underlay Install Guide

DuPont Tyvek Wall Underlay Install Guide DuPont Tyvek Wall Underlay Install Guide (For Residential & Light Commercial Buildings) Acceptable Solution to NZBC E2/AS1 New Zealand As at 1/4/15 Version 2 Subject to change without notice DuPont Tyvek

More information

Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier Typical Details (THIS PAGE INTENTIONALLY LEFT BLANK Pebbletex Wall System Class PB Exterior Insulation

More information