1 Building Performance Testing Services

2 Laboratory Testing NAFS Testing: AAMA/WDMA/CSA 101/I.S. 2/A440-05: Standard/Specification for Windows, Doors and Unit Skylights AAMA/WDMA/CSA 101/I.S. 2/A440-08: North American Fenestration Standard (NAFS)/Specification for Windows, Doors and Unit Skylights AAMA/WDMA/CSA 101/I.S. 2/A440-11: North American Fenestration Standard Glass Doors (NAFS)/Specification for Windows, Doors and Skylights 2

3 Thermal: AAMA 504: Vol. Laboratory Test Method to Qualify Fenestration Installation Procedures Air: ASTM E283: Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors ASTM E1424: Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure and Temperature Differences Across the Specimen Water: ASTM E331: Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference ASTM E547: Water Penetration of Exterior Windows, Curtain Walls, and Doors by Cyclic Static Air Pressure Differential Structural: ASTM E330: Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference 3

4 Forced Entry: ASTM F 588: Forced Entry Resistance Windows ASTM F 842: Forced Entry Resistance Doors ASTM F 476: Security of Swinging Door Assemblies AAMA 1302: Specifications for Forced Entry Resistant Aluminum Prime Windows AAMA 1303: Specifications for Forced Entry Resistant Aluminum Sliding Glass Door Systems AAMA 1304: Forced Entry Resistance of Side Hinged Door Systems Mullions: AAMA 450: Performance Rating Method for Mulled Fenestration Assemblies Secondary Tests: ASTM E 987 (Method A): Deglazing Force of Fenestration Products ASTM E 2068 (Method B): Operating Force of Sliding Windows and Doors AAMA 910: Life Cycle Specifications and Test Methods for Architectural Grade Windows and sliding Glass Doors Doors: AAMA 920: Operating Cycle Performance of Side-Hinged Exterior Door Systems AAMA 925: Vertical Loading Resistance of Side-Hinged Door Leaves AAMA : Specifications for Insulating Storm Products for Windows and Sliding Glass Doors AAMA : Specifications for Aluminum Storm Doors 4

5 Impact/Cycling: TAS 201: TAS 202: TAS 203: AAMA 506: Impact Test Procedures Criteria For Testing Impact & Nonimpact Resistant Building Envelope Components Using Uniform Static Air Pressure Criteria For Testing Products Subject To Cyclic Wind Pressure Loading Voluntary Specifications for Impact and Cycle Testing of Fenestration Products ASTM E1886: Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials ASTM E1996: Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes ANSI/AMCA: ANSI/AMCA Standard 540: Test Method for Louvers Impacted by Wind Borne Debris ANSI/AMCA 550: Test Method for High Velocity Wind Driven Resistant Louvers ICC/NSSA ICC 500 Standard for the Design and Construction of Storm Shelters 5

6 Skylights: AAMA 1600: Specification for Skylights AAMA : Standard Uniform Load Procedure for Plastic Glazed Skylights by Uniform Static AAMA 1606: Uniform Load Structural Standard for Plastic Domed Skylights Additional Testing: AAMA 1102: Voluntary Specification for Side-Hinged Secondary Storm Doors AAMA/NPEA/NSA 2100: Specifications for Sunrooms AAMA 2502: Comparative Analysis Procedure for Window and Door Products Manufactured Housing - Laboratory: AAMA & : Primary Window and Sliding Glass Door Standard for Utilization in SMA 6001: Specification for Metal Protection Screens ASTM E 1704: Standard Guide for Specifying Acoustical Performance of Sound-Isolating Enclosures 6

7 Field - Curtain Wall In-situ Testing AAMA 502: Specifications for Field Testing of Windows and Sliding Glass Doors AAMA 503: Voluntary Specification for Field Testing of Newly Installed Store fronts, Curtain Walls, and Sloped Glazing Systems AAMA 511: Voluntary Guideline for Forensic Water Penetration Testing of Fenestration Products 7

8 Air ASTM E783: Field Measurement of Air Leakage Through Installed Exterior Windows and Doors ASTM E2357: Standard Test Method for Determining Air Leakage of Air Barrier Assemblies Water: ASTM E1105: Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors and Curtain Walls by Uniform or Cyclic Static Air Pressure Difference AAMA 501.2: Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls and Sloped Glazing Systems AAMA 501.1: Water Penetration of Windows, Curtain Walls and Doors Using Dynamic Pressure Thermal: AAMA 1503: Voluntary Test Method for Thermal Transmittance and Condensation Resistance of Windows, Doors and Glazed Wall Sections 8

9 Laboratory Mock-up Curtain Wall Testing AAMA 501: Methods of Tests for Exterior Walls AAMA 501.1: Water Penetration of Windows, Curtain Walls and Doors Using Dynamic Pressure AAMA 501.4: Static Testing Method for Evaluating Curtain Wall and Storefront Systems Subjected to Seismic and wind Induced Inter-story Drift AAMA 501.5: Thermal Cycling of Exterior Walls AAMA 501.6: Recommended Dynamic Test Method for Determining the Seismic Drift Causing Glass Fallout from a Wall System AAMA 501.7: Recommend Static Test Method for Evaluating Windows, Window Wall, Curtain Wall and Storefront Systems Subjected to Vertical Inter-Story Movements AAMA 508: Voluntary Test Method and Specification for Pressure Equalized Rain Screen Wall Cladding Systems AAMA 1503: Voluntary Test Method for Thermal Transmittance and Condensation Resistance of Windows, Doors and Glazed Wall Sections 9

10 Contacts Wayne Breighner Jim Blakely Dan Daugherty Jeannette Torres Brenda Breighner

11 Thank you!

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL CERTIFIED TESTING LABORATORIES, INC. (NCTL-YORK) 5 Leigh Drive York, PA 17406 Amy Becker Phone: 717 846 1200 abecker@nctlinc.com MECHANICAL Valid To:

More information

Architectural Testing, Inc. 849 Western Avenue North Saint Paul, Minnesota Dan Johnson, Director - Regional Operations

Architectural Testing, Inc. 849 Western Avenue North Saint Paul, Minnesota Dan Johnson, Director - Regional Operations IAS Accreditation Number Company Name Address Contact Name Telephone (651) 636-3835 Effective Date of Scope August 12, 2016 Accreditation Standard ISO/IEC 17025:2005 Conformity Specifications TL-285 849

More information

ASTM E1918: standard test method for measuring solar reflectance of horizontal and lowsloped surfaces in the field

ASTM E1918: standard test method for measuring solar reflectance of horizontal and lowsloped surfaces in the field IAS Accreditation Number Company Name Address TL-264 2524 E Jensen Ave. Fresno, CA 93706 Leaton Kirk, Director - Regional Operations Contact Name Telephone (559) 233-8705 Effective Date of Scope December

More information

American Architectural Manufacturers Association VOLUME 1 - WINDOWS AND DOORS

American Architectural Manufacturers Association VOLUME 1 - WINDOWS AND DOORS VOLUME 1 - WINDOWS AND DOORS Window and Door Selection Guide PART 1 WINDOW SELECTION GUIDE WSG-11 PART 2 - PERFORMANCE SPECIFICATIONS Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows

More information

PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED

PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED Ministry of Municipal Affairs PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED CHANGE NUMBER: SOURCE: B-05-10-03 Ontario-mNBC CODE REFERENCE: Division B / 5.10.3. DESCRIPTION OF THE

More information

Performance Testing for Quality Assurance and Commissioning

Performance Testing for Quality Assurance and Commissioning BEST 4 Conference: April 13, 2015, Kansas City, MO Performance Testing for Quality Assurance and Commissioning Fiona Aldous Principal The most benefit to a project is obtained during the Design Phase -

More information

NBC 2015 SUBSECTION OTHER FENESTRATION ASSEMBLIES THE INTENT BEHIND THE NEW CODE PROVISIONS

NBC 2015 SUBSECTION OTHER FENESTRATION ASSEMBLIES THE INTENT BEHIND THE NEW CODE PROVISIONS NBC 2015 SUBSECTION 5.9.3 OTHER FENESTRATION ASSEMBLIES THE INTENT BEHIND THE NEW CODE PROVISIONS D.G. Kayll 1, G.R. Torok 2, and R. Jutras 3 ABSTRACT In Canada, the design, construction and installation

More information

AQUARIUS CONDOMINIUM 40 YEAR RESTORATION PROJECT & RELATED WORK. Wind Pressure Drawings: Openings, Specs, NOA s / Product Approvals

AQUARIUS CONDOMINIUM 40 YEAR RESTORATION PROJECT & RELATED WORK. Wind Pressure Drawings: Openings, Specs, NOA s / Product Approvals AQUARIUS CONDOMINIUM 2751 SOUTH OCEAN DRIVE HOLLYWOOD, FLORIDA 33019 40 YEAR RESTORATION PROJECT & RELATED WORK Wind Pressure Drawings: Openings, Specs, NOA s / Product Approvals ENGINEER S PROJECT # 7478-16

More information

Why test a system that has already been tested? Typical Manufacturers information for window to wall interface and basis for reported test results.

Why test a system that has already been tested? Typical Manufacturers information for window to wall interface and basis for reported test results. 1 Pre-Construction Phase, & the Laboratory or Field Mock-Up Building Enclosure Commissioning: Train the Trainer Iowa State University, Ames Iowa May 10 12, 2016 Presented by Fiona Aldous Why test a system

More information

BUILDING DESIGN STANDARDS FACILITIES MANAGEMENT AND ANCILLARY SERVICES DOORS AND OPENINGS - DIVISION 08 Windows

BUILDING DESIGN STANDARDS FACILITIES MANAGEMENT AND ANCILLARY SERVICES DOORS AND OPENINGS - DIVISION 08 Windows Part 1 General 1.1 Summary.1 Unless otherwise indicated, follow the standards below when specifying new windows. These standards are not intended to restrict or replace professional judgment..2 The current

More information

Section Aluminum Windows (2700 Model Specifications)

Section Aluminum Windows (2700 Model Specifications) Section 08520 - Aluminum Windows (2700 Model Specifications) I. GENERAL: 1.01 Scope of Work A. Furnish all necessary materials, labor, and equipment for the complete installation of aluminum windows for

More information

Section Aluminum Windows (2700 Model Specifications)

Section Aluminum Windows (2700 Model Specifications) Section 08520 - Aluminum Windows (2700 Model Specifications) I. GENERAL: 1.01 Scope of Work A. Furnish all necessary materials, labor, and equipment for the complete installation of aluminum windows for

More information

NAFS Labeling and Part 5 Compliance for Commercial Glazing Products. A Guide for Architects

NAFS Labeling and Part 5 Compliance for Commercial Glazing Products. A Guide for Architects NAFS Labeling and Part 5 Compliance for Commercial Glazing Products A Guide for Architects An informational resource from the Fenestration Association of BC Executive summary NAFS labeling requirements

More information

Interaction Between the Building Envelope and Fenestration Products

Interaction Between the Building Envelope and Fenestration Products Interaction Between the Building Envelope and Fenestration Products Dave Stammen Robert Jutras Underwriters Laboratories (UL) Air Barrier Association of America (ABAA) is a Registered Provider with The

More information

VELUX America Inc. SPECIFICATION FOR MODEL QPF SELF-FLASHED FIXED SKYLIGHT SECTION UNIT SKYLIGHTS

VELUX America Inc. SPECIFICATION FOR MODEL QPF SELF-FLASHED FIXED SKYLIGHT SECTION UNIT SKYLIGHTS SECTION 08620 UNIT SKYLIGHTS PART 1 GENERAL 1.01 SECTION INCLUDES A. Performance and product component information for VELUX QPF selfflashed fixed skylight. B. Unit skylight mounted directly to roof decking.

More information

Field Determination of Water Penetration of Windows using Blowerdoor and Infrared Camera

Field Determination of Water Penetration of Windows using Blowerdoor and Infrared Camera Field Determination of Water Penetration of Windows using Blowerdoor and Infrared Camera Walter Sebastian BMT Building Enviroment Consultants Ltd., Doktor Neergaards Vej 15, DK-2970 Hoersholm, Denmark

More information

NAFS and the Building Code New ratings, new concepts, new terminology

NAFS and the Building Code New ratings, new concepts, new terminology NAFS and the Building Code New ratings, new concepts, new terminology Al Jaugelis B.Sc. Arch. ajaugelis@rdhbe.com Version: 2013 12 03 What is NAFS? A NEW STANDARD for testing and rating fenestration product

More information

Field Testing and Forensic Analysis for Manufacturers

Field Testing and Forensic Analysis for Manufacturers AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION Field Testing and Forensic Analysis for Manufacturers AAMA Special Event Webinar April 28, 2015 Welcome AAMA Members Licensees Other manufacturers Industry

More information

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

Signature Series 5 Lap SECTION ALUMINUM WINDOWS Signature Series 5 Lap SECTION 08 51 13 ALUMINUM WINDOWS PART 1 GENERAL 1.01 SUMMARY A. Related Documents: Conditions of the Contract, Division 1 - General Requirements, and Drawings apply to Work of this

More information

Section Sliding Aluminum Framed Glass Doors (2500 Model Specifications)

Section Sliding Aluminum Framed Glass Doors (2500 Model Specifications) Section 083213 - Sliding Aluminum Framed Glass Doors (2500 Model Specifications) I. GENERAL: SECTION 083213 SLIDING ALUMINUM- FRAMED GLASS DOORS 1.01 Scope of Work A. Furnish all necessary materials, labor,

More information

SECTION ALUMINUM WINDOWS

SECTION ALUMINUM WINDOWS SECTION 08520 ALUMINUM WINDOWS PART 1 GENERAL 1.1 SECTION INCLUDES A. Projected windows. B. Fixed windows. 1.2 RELATED SECTIONS A. Section 07900: Joint Sealers. B. Section 08400: Entrances and Storefronts.

More information

Technical Update: Airtightness and Water Penetration Testing for Residential Buildings

Technical Update: Airtightness and Water Penetration Testing for Residential Buildings GREEN BUILDING PROGRAM Technical Update: 2017-07-11 Airtightness and Water Penetration for Technical Update 2017-07-11 Airtightness and Water Penetration for Guideline 1 GREEN BUILDING PROGRAM GUIDELINES

More information

ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Version 3.0 October 1, 2010

ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Version 3.0 October 1, 2010 ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Below is the product criteria for ENERGY STAR qualified residential windows, doors, and skylights sold in Canada

More information

SECTION METAL WALL PANEL SYSTEM

SECTION METAL WALL PANEL SYSTEM CSI Format for Metal Wall Panel System Specification SECTION 07410 METAL WALL PANEL SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. Exterior Metal Plate Wall Panels B. Substructure and Framing C. Structural

More information

Section Aluminum Windows (M-85 Series Specifications)

Section Aluminum Windows (M-85 Series Specifications) Section 08520 - Aluminum Windows (M-85 Series Specifications) I. GENERAL: 1.01 Scope of Work A. Furnish all necessary materials, labor, and equipment for the complete installation of aluminum windows for

More information

Storefront Selection Guide

Storefront Selection Guide Selection Guide YES 20 Sash Framing A 1 x 2 fl ush glazed or center glazed sash window system. YES 40 FS A 1-3/4 x 4 center set, fl ush glazed, monolithic glazed storefront system with available hinged

More information

SSG. Fundamentals of Structural Sealant Glazing. Introduction

SSG. Fundamentals of Structural Sealant Glazing. Introduction SSG Fundamentals of Structural Sealant Glazing Photos Courtesy of SmithGroup Introduction This presentation is about the use of silicone sealants for structural sealant glazing (SSG) Information on sealants

More information

Intertek NAFS-11 Testing

Intertek NAFS-11 Testing www.thedsgroup.com Tomorrow s Innovative Solutions for Today s Doors & Windows The DS Group Of Companies: Draftseal, Kristrack, Eclipse Architectural & DSD Hardware Intertek NAFS-11 Testing Intertek has

More information

STRUCTURAL DESIGN CRITERIA

STRUCTURAL DESIGN CRITERIA CHAPTER 3 STRUCTURAL DESIGN CRITERIA SECTION 301 GENERAL 301.1 Scope. Loads and load combinations shall be determined in accordance with ASCE 7 unless otherwise noted. Structural elements of the storm

More information

Code Compliance Research Report CCRR-0131

Code Compliance Research Report CCRR-0131 Code Compliance Research Report CCRR-0131 Issued: 10-27-2008 Renewal Due: 07-13-2018 Revised: 09-29-2017 DIVISION: 08 00 00 OPENINGS Section: 08 62 00 Unit Skylights REPORT HOLDER: Solatube International,

More information

Section Aluminum Windows (M950/M950B Series Specifications)

Section Aluminum Windows (M950/M950B Series Specifications) Section 08520 - Aluminum Windows (M950/M950B Series Specifications) I. GENERAL: 1.01 Scope of Work A. Furnish all necessary materials, labor, and equipment for the complete installation of aluminum windows

More information

LOCAL LAWS OF THE CITY OF NEW YORK FOR THE YEAR No. 101

LOCAL LAWS OF THE CITY OF NEW YORK FOR THE YEAR No. 101 LOCAL LAWS OF THE CITY OF NEW YORK FOR THE YEAR 2013 No. 101 Proposed by Council Members Richards, Chin, James, Koo, Lander, Mendez, Recchia, Rose, Barron, and Van Bramer. A LOCAL LAW To amend the New

More information

FLORIDA BUILDING CODE

FLORIDA BUILDING CODE ASCE 7 10 WIND ZONE MAP RISK CATEGORY II 6 DESIGNATED AREAS WHERE THE BASIC WIND SPEED IS 140 MPH OR GREATER 130 MPH AND WITHIN 1 MILE OF COAST NOTE: THIS MAP IS ACCURATE TO THE COUNTY, IT IS NOT TO BE

More information

Section Aluminum Windows (4500 Series Specifications)

Section Aluminum Windows (4500 Series Specifications) Section 08520 - Aluminum Windows (4500 Series Specifications) I. GENERAL: 1.01 Scope of Work A. Furnish all necessary materials, labor, and equipment for the complete installation of aluminum windows for

More information

2003 PUBLICATIONS CATALOG

2003 PUBLICATIONS CATALOG American Architectural Manufacturers Association 2003 PUBLICATIONS CATALOG The Source of Performance Standards, Product Certification and Educational Programs for the Fenestration Industry. APRIL 2003

More information

ENERGY STAR Technical Specification for Residential Windows, Doors, and Skylights Sold in Canada Version 4.0 February 1, 2015

ENERGY STAR Technical Specification for Residential Windows, Doors, and Skylights Sold in Canada Version 4.0 February 1, 2015 ENERGY STAR Technical Specification for Residential Windows, Doors, and Skylights Sold in Canada This technical specification determines how residential windows, doors, and skylights sold in Canada qualify

More information

SERIES 8510 AW-PG85-FW FIXED WINDOW

SERIES 8510 AW-PG85-FW FIXED WINDOW PART 1 - GENERAL 1.1 SCOPE OF WORK SERIES 8510 AW-PG85-FW FIXED WINDOW SECTION 08 51 13 ALUMINUM WINDOWS A. Furnish and install aluminum windows as shown in bid drawings and as per specifications stipulated

More information

SERIES 2100 CW-PG60-FW FIXED WINDOW

SERIES 2100 CW-PG60-FW FIXED WINDOW PART 1 - GENERAL 1.1 SCOPE OF WORK SERIES 2100 CW-PG60-FW FIXED WINDOW SECTION 08 51 13 ALUMINUM WINDOWS A. Furnish and install aluminum windows as shown in bid drawings and as per specifications stipulated

More information

STRUCTURAL PERFORMANCE TEST REPORT. Series Casement (Rep/Impact/AAMA) C-C70 940mm x 1930mm (37 x 76 )

STRUCTURAL PERFORMANCE TEST REPORT. Series Casement (Rep/Impact/AAMA) C-C70 940mm x 1930mm (37 x 76 ) Element Materials Technology 115 South 84th Ave Wausau, WI 54401, USA 407-505-8102 Report No.: ESP101311P-6_012404P-6 Report Date: July 18, 2012 STRUCTURAL PERFORMANCE TEST REPORT Test Requested By: Earthwise

More information

SECTION STAINLESS STEEL WALL PANELS

SECTION STAINLESS STEEL WALL PANELS SECTION 07400 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Dry joint, Rainscreen stainless steel wall panel system. 2. Accessories including attachments, clips, sub girts, shims, and fasteners 3.

More information

Chapter 8 - Testing. Ernst W. Kiesling, P.E., Ph.D. Professor of Civil Engineering. and. Executive Director

Chapter 8 - Testing. Ernst W. Kiesling, P.E., Ph.D. Professor of Civil Engineering. and. Executive Director ICC/NSSA Standards Preview Chapter 8 - Testing by Ernst W. Kiesling, P.E., Ph.D. Professor of Civil Engineering Texas Tech University and Executive Director National Storm Shelter Association (NSSA) presented

More information

SERIES 8520 AW-PG80-AP PROJECT-OUT AWNING WINDOW

SERIES 8520 AW-PG80-AP PROJECT-OUT AWNING WINDOW PART 1 - GENERAL 1.1 SCOPE OF WORK SERIES 8520 AW-PG80-AP PROJECT-OUT AWNING WINDOW SECTION 08 51 13 ALUMINUM WINDOWS A. Furnish and install aluminum windows as shown in bid drawings and as per specifications

More information

SERIES 5100 AW-PG100-FW FIXED WINDOW

SERIES 5100 AW-PG100-FW FIXED WINDOW PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 08 51 13 ALUMINUM WINDOWS A. Furnish and install aluminum windows as shown in bid drawings and as per specifications stipulated in this section. B. Factory-installed

More information

Code Requirements For Residential Windows & Doors

Code Requirements For Residential Windows & Doors International NEW 2016 EDITION! Code Requirements For Residential Windows & Doors Courtesy of the American Architectural Manufacturers Association The family of International Codes published by the International

More information

COMMERCIAL FENESTRATION FUNDAMENTALS & DESIGN CONSIDERATIONS

COMMERCIAL FENESTRATION FUNDAMENTALS & DESIGN CONSIDERATIONS COMMERCIAL FENESTRATION FUNDAMENTALS & DESIGN CONSIDERATIONS INTRODUCTION Pace Representatives is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned

More information

AAMA Voluntary Specification for the Water Penetration Resistance & Structural Load Performance of Locking/ Latching Hardware Used In

AAMA Voluntary Specification for the Water Penetration Resistance & Structural Load Performance of Locking/ Latching Hardware Used In A M E R I C A N A R C H I T E C T U R A L AAMA 930-03 Voluntary Specification for the Water Penetration Resistance & Structural Load Performance of Locking/ Latching Hardware Used In Side-Hinged Door Systems

More information

NanaWall Matching Windows and Doors Table of Contents

NanaWall Matching Windows and Doors Table of Contents NanaWall Matching Windows and Doors Table of Contents Matching Windows and Doors Cross Sections and Maximum Frame Charts Introduction.............................................................. 1 NanaWall

More information

Julie Glover and Kevin Brown KTA-Tator, Inc. Wind-Driven Rain Assessment

Julie Glover and Kevin Brown KTA-Tator, Inc. Wind-Driven Rain Assessment Julie Glover and Kevin Brown KTA-Tator, Inc. Wind-Driven Rain Assessment Explain the differences between waterproof, weatherproof, and water repellent. Identify a laboratory test method used for determining

More information

3 Season Porch Windows

3 Season Porch Windows 3 Season Porch Windows Technical Information Quad pulley balance system for smooth and reliable operation Stainless steel aircraft cable supports the counterbalanced sashes for easy ventilation Dual sashes

More information

4 1 2" Sliding Door WINDOW ELEVATIONS FEATURES OPTIONAL O-X SLIDING DOOR X-O SLIDING DOOR VER:

4 1 2 Sliding Door WINDOW ELEVATIONS FEATURES OPTIONAL O-X SLIDING DOOR X-O SLIDING DOOR VER: WINDOW ELEVATIONS 4 1 2" Sliding Door 1 1 3 4 5 5 4 3 2 1280 1280 2 1280-2 O-X SLIDING DOOR 1280-2 X-O SLIDING DOOR FEATURES 4-1/2" FRAME DEPTH 1" INSULATED GLASS HEAVY-DUTY LATCH HANDLE FIBERMESH LOCKING

More information

SECTION (08520) - ALUMINUM WINDOWS

SECTION (08520) - ALUMINUM WINDOWS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: SECTION 08 51 13 (08520) - ALUMINUM WINDOWS 1. Operating and Fixed Aluminum Window Units a. Horizontal Sliding Units b. Horizontal Sliding Units Above Louver

More information

ENERGY STAR Technical Specification for Residential Windows, Doors, and Skylights Sold in Canada Version 5.0 January 1, 2020 FINAL (Without Skylights)

ENERGY STAR Technical Specification for Residential Windows, Doors, and Skylights Sold in Canada Version 5.0 January 1, 2020 FINAL (Without Skylights) ENERGY STAR Technical Specification for Residential Windows, Doors, and Skylights Sold in Canada Version 5.0 January 1, 2020 FINAL (Without Skylights) This technical specification determines how residential

More information

ENERGY STAR Technical Specification for Residential Windows, Doors, and Skylights Sold in Canada Version 5.0 January 1, 2020 FINAL

ENERGY STAR Technical Specification for Residential Windows, Doors, and Skylights Sold in Canada Version 5.0 January 1, 2020 FINAL ENERGY STAR Technical Specification for Residential Windows, Doors, and Skylights Sold in Canada Version 5.0 January 1, 2020 FINAL This technical specification determines how residential windows, doors,

More information

Corium Brick Rainscreen System Specifications

Corium Brick Rainscreen System Specifications CORIUM BRICK RAINSCREEN SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Work Included: The Work of this Section shall include but not be limited to the following: 1. Corium brick plates 2. Galvanized and coated

More information

TEST REPORT. Rendered to: ALL WEATHER ARCHITECTURAL ALUMINUM Vacaville, California. SERIES/MODEL: 6000 PRODUCT TYPE: Aluminum Awning Window

TEST REPORT. Rendered to: ALL WEATHER ARCHITECTURAL ALUMINUM Vacaville, California. SERIES/MODEL: 6000 PRODUCT TYPE: Aluminum Awning Window TEST REPORT Report No.: D8932.01-301-44 Rendered to: ALL WEATHER ARCHITECTURAL ALUMINUM Vacaville, California SERIES/MODEL: 6000 PRODUCT TYPE: Aluminum Awning Window SPECIFICATION: AAMA/WDMA/CSA 101/I.S.2/A440-08,

More information

SERIES 1400 ATD-HC50 ARCHITECTURAL TERRACE DOOR

SERIES 1400 ATD-HC50 ARCHITECTURAL TERRACE DOOR SECTION 08 11 16 ALUMINUM DOORS AND FRAMES PART 1 - GENERAL 1.1 SCOPE OF WORK A. Furnish and install aluminum windows as shown in bid drawings and as per specifications stipulated in this section. B. Factory-installed

More information

SERIES 8000 AW-PG90-C CASEMENT OUTSWING WINDOW

SERIES 8000 AW-PG90-C CASEMENT OUTSWING WINDOW PART 1 - GENERAL 1.1 SCOPE OF WORK SERIES 8000 AW-PG90-C CASEMENT OUTSWING WINDOW SECTION 08 51 13 ALUMINUM WINDOWS A. Furnish and install aluminum windows as shown in bid drawings and as per specifications

More information

PROJECTED & CASEMENT WINDOWS ALUMINUM WINDOWS

PROJECTED & CASEMENT WINDOWS ALUMINUM WINDOWS ENVIRONMENTAL PRODUCT DECLARATION PROJECTED & CASEMENT WINDOWS ALUMINUM WINDOWS Kawneer Company, Inc., part of Arconic's global Building and Construction Systems (BCS) business, has provided the commercial

More information

CENTRA WINDOWS. Manufacturer for Centra Construction Group of Companies

CENTRA WINDOWS. Manufacturer for Centra Construction Group of Companies CENTRA WINDOWS Manufacturer for Centra Construction Group of Companies Windows and Doors What to look for By Anton Van Dyk What does the Building Code Cover: Thermal Performance December, 2014 Air, Water

More information

Manitoba Energy Code for Buildings. Part 3 Building Envelope

Manitoba Energy Code for Buildings. Part 3 Building Envelope Manitoba Energy Code for Buildings Part 3 Building Envelope Rick Marshall, P. Eng, LEED AP September 17, 2014 Manitoba Energy Code for Buildings (MECB) Training Day Part 3 - Scope Part 3 is concerned with

More information

SoCal Dynamic Dome Skylight SECTION UNIT SKYLIGHTS

SoCal Dynamic Dome Skylight SECTION UNIT SKYLIGHTS VELUX SECTION 08 62 00 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Dynamic dome unit skylight with formed curb counterflashing for mounting on site-built or prefabricated roof curbs, for flat, low-slope and

More information

A. Section Cast-In-Place Concrete: Openings in cast-in-place concrete.

A. Section Cast-In-Place Concrete: Openings in cast-in-place concrete. Euro Vista Multi Slide Impact Rated Multi Slide Door PART 1 GENERAL 1.1 SECTION INCLUDES A. Sliding/Folding Doors. 1.2 RELATED SECTIONS A. Section 03300 - Cast-In-Place Concrete: Openings in cast-in-place

More information

HUNG & SLIDING WINDOWS ALUMINUM WINDOWS

HUNG & SLIDING WINDOWS ALUMINUM WINDOWS ENVIRONMENTAL PRODUCT DECLARATION HUNG & SLIDING WINDOWS ALUMINUM WINDOWS Kawneer Company, Inc., part of Arconic's global Building and Construction Systems (BCS) business, has provided the commercial construction

More information

SECTION ALL ULTREX DOUBLE HUNG WINDOW

SECTION ALL ULTREX DOUBLE HUNG WINDOW SECTION 08 54 13 ALL ULTREX DOUBLE HUNG WINDOW PART 1 GENERAL 1.1 SECTION INCLUDES A. All Ultrex double hung window complete with hardware, glazing, weather strip, insect screen and half screen, grillesbetween-the

More information

BUILDING ENCLOSURE COMMISSIONING PLAN PROJECT NAME

BUILDING ENCLOSURE COMMISSIONING PLAN PROJECT NAME BUILDING ENCLOSURE COMMISSIONING PLAN For The PROJECT NAME Building Enclosure Commissioning Plan Overview The purpose of the Building Enclosure Commissioning Plan is to provide a clear and concise roadmap

More information

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A AAMA TEST REPORT SUMMARY

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A AAMA TEST REPORT SUMMARY AAMA/WDMA/CSA 101/I.S.2/A440-08 AAMA/WDMA/CSA 101/I.S.2/A440-05 AAMA 910-93 TEST REPORT SUMMARY Rendered to: GIESSE NORTH AMERICA 2014 Holston Industrial Drive Blountville, TN 37617 PRODUCT TYPE: XO Sliding

More information

SECTION ALUMINUM WINDOWS

SECTION ALUMINUM WINDOWS SECTION 08520 ALUMINUM WINDOWS 1. PART 1 GENERAL 1.1 WORK INCLUDED: 1. Provide labor, material, equipment and services to furnish and install aluminum windows shown on drawings and specified herein. Window

More information

Standard test method for wood preservatives by laboratory soil-block cultures

Standard test method for wood preservatives by laboratory soil-block cultures IAS Accreditation Number Company Name Address Contact Name TL-259 257 East Randolph Street Nappanee, Indiana 46550 Dale Arter Director of Testing & Certification Telephone (574) 773-7975 Effective Date

More information

2007 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (TAS)

2007 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (TAS) TESTING APPLICATION STANDARD (TAS) 202-94 CRITERIA FOR TESTING IMPACT & NONIMPACT RESISTANT BUILDING ENVELOPE COMPONENTS USING UNIFORM STATIC AIR PRESSURE 1. 2. 3. Scope: 1.1 This protocol covers procedures

More information

Series B450 Guide Specification

Series B450 Guide Specification Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com STOREFRONT SERIES B450 Shear Block Air Infiltration:

More information

SERIES 9000 AW-PG70-DAW DUAL ACTING WINDOW (TILT/TURN)

SERIES 9000 AW-PG70-DAW DUAL ACTING WINDOW (TILT/TURN) PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 08 51 13 ALUMINUM WINDOWS A. Furnish and install aluminum windows as shown in bid drawings and as per specifications stipulated in this section. B. Factory-installed

More information

Specifying Windows and Doors Using Performance Standards

Specifying Windows and Doors Using Performance Standards 1 Specifying Windows and Doors Using Performance Standards 2 This program is registered with the AIA/CES for continuing professional education. As such, it does not include content that may be deemed or

More information

Commissioning Under the Influence

Commissioning Under the Influence Commissioning Under the Influence Redefining the Traditional Role of the Commissioning Agent in the Design and Construction of the Building Envelope National Conference on Building Commissioning: May 2-4,

More information

STRUCTURAL DESIGN CRITERIA

STRUCTURAL DESIGN CRITERIA CHAPTER 3 STRUCTURAL DESIGN CRITERIA SECTION 301 GENERAL 301.1 Scope. Loads and load combinations shall be determined in accordance with ASCE 7 unless otherwise noted. Structural elements of the storm

More information

ENERGY STAR Technical Specification for Residential Windows, Doors, and Skylights Sold in Canada Version 5.0 January 1, 2020 FINAL

ENERGY STAR Technical Specification for Residential Windows, Doors, and Skylights Sold in Canada Version 5.0 January 1, 2020 FINAL ENERGY STAR Technical Specification for Residential Windows, Doors, and Skylights Sold in Canada Version 5.0 January 1, 2020 FINAL This technical specification determines how residential windows, doors,

More information

Water Penetration and Air Leakage Testing of Flanged Window Details

Water Penetration and Air Leakage Testing of Flanged Window Details Water Penetration and Air Leakage Testing of Flanged Window Details T. Brown, J. Posenecker, K. Simon BES/Terracon and JE Dunn Construction Air Barrier Association of America (ABAA) is a Registered Provider

More information

Guideline for Building Envelope Commissioning: New Buildings

Guideline for Building Envelope Commissioning: New Buildings Guideline for Building Envelope Commissioning: New Buildings Introduction Building envelope failures may arise from inadequacies in the design, construction and operation of buildings and appear to be

More information

SECTION ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS

SECTION ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS PART 1 GENERAL SECTION 08 1116 ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS 1.01 SECTION INCLUDES A. Aluminum-framed storefront, with vision glass. B. Infill panels of glass. C. Aluminum doors

More information

SERIES 6200 HS-HC60 HORIZONTAL SLIDING WINDOW

SERIES 6200 HS-HC60 HORIZONTAL SLIDING WINDOW SECTION 08 51 13 ALUMINUM WINDOWS PART 1 - GENERAL 1.1 SCOPE OF WORK A. Furnish and install aluminum windows as shown in bid drawings and as per specifications stipulated in this section. B. Factory-installed

More information

TESTING APPLICATION STANDARD (TAS) CRITERIA FOR TESTING PRODUCTS SUBJECT TO CYCLIC WIND PRESSURE LOADING

TESTING APPLICATION STANDARD (TAS) CRITERIA FOR TESTING PRODUCTS SUBJECT TO CYCLIC WIND PRESSURE LOADING TESTING APPLICATION STANDARD (TAS) 203-94 CRITERIA FOR TESTING PRODUCTS SUBJECT TO CYCLIC WIND PRESSURE LOADING 1. 2. 3. Scope: 1.1 This protocol covers procedures for conducting the cyclic wind pressure

More information

TESTING APPLICATION STANDARD (TAS) CRITERIA FOR TESTING PRODUCTS SUBJECT TO CYCLIC WIND PRESSURE LOADING

TESTING APPLICATION STANDARD (TAS) CRITERIA FOR TESTING PRODUCTS SUBJECT TO CYCLIC WIND PRESSURE LOADING TESTING APPLICATION STANDARD (TAS) 203-94 CRITERIA FOR TESTING PRODUCTS SUBJECT TO CYCLIC WIND PRESSURE LOADING 1. 2. 3. Scope: 1.1 This protocol covers procedures for conducting the cyclic wind pressure

More information

SIDE HINGED SECURITY ALUMINUM WINDOWS

SIDE HINGED SECURITY ALUMINUM WINDOWS 08 51 13.11 PART 1 - GENERAL 1.1 SECTION INCLUDES: A. Material: aluminum windows as on the drawings and specified in this section. B. Installation: labor, tools, and material needed to install aluminum

More information

SERIES 5500 H-HC60 DOUBLE-HUNG TILT WINDOW

SERIES 5500 H-HC60 DOUBLE-HUNG TILT WINDOW SECTION 08 51 13 ALUMINUM WINDOWS PART 1 - GENERAL 1.1 SCOPE OF WORK A. Furnish and install aluminum windows as shown in bid drawings and as per specifications stipulated in this section. B. Factory-installed

More information

ICC/NSSA STANDARD FOR THE DESIGN AND CONSTRUCTION OF STORM SHELTERS ICC

ICC/NSSA STANDARD FOR THE DESIGN AND CONSTRUCTION OF STORM SHELTERS ICC Standards Action - May 2, 2014 - Page 43 of 50 Pages International Code Council ICC/NSSA STANDARD FOR THE DESIGN AND CONSTRUCTION OF STORM SHELTERS ICC 500-2013 edition Public Comment Draft #3 The ICC

More information

Construction Consulting Laboratory, International

Construction Consulting Laboratory, International Construction Consulting Laboratory, International Test Report CCLI-14-060 Client MI Windows and Doors, LLC. 1001 West Crosby Road Carrollton, TX 75006 Product Type: Aluminum Fixed Window Series / Model:

More information

14 Product Selection Guide

14 Product Selection Guide 14 Selection Guide 1600 Wall System TM 1 1600 Wall System TM 2 1600 Wall System TM 3 1600 Wall System TM 4 Catalog Section s s s s Sightline 2-1/2" 2-1/2" 2-1/2" 2-1/4" Depths 6", 7-1/2" 6", 7-1/2" 6",

More information

Designation: TTU NWI DIF Air Bladder Standard Scope

Designation: TTU NWI DIF Air Bladder Standard Scope Designation: TTU NWI DIF Air Bladder Standard 1.1.2016 Standard Test Method for Structural Performance of Exterior Doors, Windows, Curtain Walls, and Skylights by Uniform Static Air Pressure Difference

More information

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS SECTION 08 4113 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Aluminum entrance doors and frames. 2. Glass infill panels. 3. Door hardware. B. Related Sections:

More information

State Product Approval, The Florida Building Code and the Florida Energy Conservation Code (6 th Edition)

State Product Approval, The Florida Building Code and the Florida Energy Conservation Code (6 th Edition) State Product Approval, The Florida Building Code and the Florida Energy Conservation Code (6 th Edition) Codes and Standards Mo Madani, CBO, Technical Unit Director Joe Bigelow, Training Design 1 Contents

More information

TEST REPORT. Report No.: A Rendered to: DEALERS SUPPLY AND LUMBER CO., LLC Greenville, South Carolina

TEST REPORT. Report No.: A Rendered to: DEALERS SUPPLY AND LUMBER CO., LLC Greenville, South Carolina Architectural Testing TEST REPORT Report No.: A6303.08-250-44 Rendered to: DEALERS SUPPLY AND LUMBER CO., LLC Greenville, South Carolina PRODUCT TYPE: Double Hung Window SERIES/MODEL: VictorBilt Palmetto

More information

TEST REPORT. Report No.: G Rendered to: C.R. LAURENCE CO., INC. Vernon, California

TEST REPORT. Report No.: G Rendered to: C.R. LAURENCE CO., INC. Vernon, California TEST REPORT Report No.: G8680.01-303-47 Rendered to: C.R. LAURENCE CO., INC. Vernon, California PRODUCT TYPE: Double Side Hinged Door - Outswing SERIES/MODEL: 925 Title Summary of Results Design Pressure

More information

Windows & Deal Trays Maximum security for high-threat locations

Windows & Deal Trays Maximum security for high-threat locations Windows & Deal Trays Maximum security for high-threat locations Ross high security aluminum and steel windows and deal trays are certified to withstand 5 or 15 minutes of simulated mob attack and rifle-level

More information

SWING DOOR SPECIFICATION

SWING DOOR SPECIFICATION SWING DOOR A1 Work included: Furnish all necessary materials, labour and equipment for the complete installation of aluminum entrance doors, door frames and hardware as detailed on the drawings and specified

More information

SECTION GLAZED ALUMINUM CURTAIN WALLS PART 1 GENERAL 1.01 RELATED DOCUMENTS

SECTION GLAZED ALUMINUM CURTAIN WALLS PART 1 GENERAL 1.01 RELATED DOCUMENTS SECTION 08 4413 - PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Building Envelope Commissioning and Building Diagnostic Test: Case Studies Course Number: CXENERGY1506

Building Envelope Commissioning and Building Diagnostic Test: Case Studies Course Number: CXENERGY1506 AABC Commissioning Group AIA Provider Number: 50111116 Building Envelope Commissioning and Building Diagnostic Test: Case Studies Course Number: CXENERGY1506 Dan Adam, RA, CxA, Facility Commissioning Group

More information

Comparison of UK Window Standards to Canadian Standards

Comparison of UK Window Standards to Canadian Standards WESTLab Canada NFRC Accredited Simulation Laboratory CWDMA Approved Simulation Laboratory Final Report Comparison of UK Window Standards to Canadian Standards Prepared for: Robin Sinha NRCan 580 Booth

More information

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana Architectural Testing TEST REPORT Report No.: D0162.01-201-44 Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana PRODUCT TYPE: Pressure Equalized Rainscreen SERIES/MODEL: 4 mm Composite

More information

FL550T 21/2 x5. GUIDE SPECIFICATION Series FL550T Thermal (21/2 x 5 ) Impact-Resistant Storefront. Thermal Impact-Resistant Storefront

FL550T 21/2 x5. GUIDE SPECIFICATION Series FL550T Thermal (21/2 x 5 ) Impact-Resistant Storefront. Thermal Impact-Resistant Storefront Series FL550T Thermal (21/2 x 5 ) Impact-Resistant Storefront Manufacturer: Coral Architectural Products 3010 Rice Mine Road Tuscaloosa, AL. 35406 Voice: (800) 772-7737 Fax: (800) 443-6261 SECTION 08410

More information

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Hurricane System

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Hurricane System Welcome to the SAFTIFIRST TM Guide Specification System prepared as an aid to specifiers in preparing written construction documents. For specification assistance with specific product applications, please

More information