1 E LECTRICAL ELECTRICAL Cables

2 July 28, 2009 CONDUMEX INCORPORATED WIRE & CABLE PRODUCT INDEX BUILDING WIRE MTW/THHN/THWN 600 VOLTS COPPER 14 AWG SOLID 750 MCM STRANDED UL 83 XHHW VOLTS COPPER 14 AWG 1000 MCM STRANDED UL 44 RHH-RHW-USE 600 VOLTS COPPER (XLP) 6 AWG 1000 MCM STRANDED UL 44 MC Cable XHHW or XHHW VOLTS ALUMINUM POWER CABLE PRIMARY URD CABLES, 15 KV 35 KV, 100% & 133% INSULATION LEVELS, COPPER OR ALUMINUM CONDUCTOR, EPR OR TR-XLP INSULATION, CONCENTRIC COPPER WIRE NEUTRAL, WITH OR WITHOUT ENCAPSULATING JACKET OVERALL : ICEA S & AEIC CS8 TYPE MV-90 & MV-105 (EPR INSULATION ONLY FOR MV-105) POWER CABLE, 5 KV - 35 KV, 100% & 133% INSULATION LEVELS, COPPER CONDUCTOR, EPR OR XLP INSULATION, COPPER DRAIN WIRE OR COPPER TAPE METALLIC SHIELD, BLACK PVC SUNLIGHT RESISTANT JACKET. SINGLE CONDUCTOR CONSTRUCTION. LISTED UL 1072; : ICEA S & AEIC CS8 TYPE MC ARMORED CABLES, 600 VOLTS, 5 KV - 15 KV, MULTI-CONDUCTOR STRANDED COPPER, EPR OR XLP INSULATION, ALUMINUM OR GALVANIZED STEEL INTERLOCKED ARMOR, PVC SUNLIGHT RESISTANT JACKET OVERALL. UL 1569 HIGH VOLTAGE POWER CABLES UP TO 138 KV, COPPER OR ALUMINUM CONDUCTOR, XLP UNSULATION, METALLIC SHIELD,PVC JACKET.SPECIFICATION: AEIC Cs7 BARE OVERHEAD CONDUCTORS, TYPES AAC AND ACSR, PER ASTM B230 & B232 VULCANEL EPR ANTILLAMA CABLE 600 VOLT NETWORK CABLE TRAY CABLE TYPE TC/THHN 600 VOLTS COPPER 14 AWG STRANDED 750 MCM STRANDED, 3 AND/OR 4 CONDUCTOR, WITH OR WITHOUT BARE GROUND WIRE (SIZES 8 AWG AND LARGER), UP TO 16 CONDUCTOR FOR SIZES 14, 12 AND 10 AWG UL 1277, ER LISTED TYPE TC/XHHW VOLTS COPPER 14 AWG STRANDED 750 MCM STRANDED, 3 AND/OR 4 CONDUCTOR, WITH OR WITHOUT BARE GROUND WIRE (SIZES 8 AWG AND LARGER), UP TO 16 CONDUCTOR FOR SIZES 14, 12 AND 10 AWG UL 1277, ER LISTED TYPE TC/XHHW VOLTS COPPER 10 TO 14 AWG STRANDED,UP TO 19 CONDUCTOR ON 12 AND 14 AWG AND 12 CONDUCTORS ON 10 AWG, UL LISTED FOR ER AND DIRECT BURIAL SPECIAL PURPOSE CABLES TYPE RHH-RHW 2000 VOLTS, (DLO), SINGLE CONDUCTOR TINNED COPPER, ROPE-LAY STRANDED, EPR INSULATION, SEPARATOR, BLACK CSPE JACKET. CONDUCTOR SIZES 4 AWG 1 AWG UL LISTED AS VW-1; SIZES 1/0 AWG MCM UL LISTED FOR CT USE, CSA LISTED AS FT4. SIZE 1111 MCM IS PER ICEA S

3 Notes: Condumex Wire and Cable th Street - Grand Prairie, TX (800)

4 TYPE MC Metal Clad Cables THHN/THWN 600V Armalat T.M. 1) Soft annealed wire or stranded class C copper conductor 2) PVC insulation/nylon jacket with color identification Types: THHN-THWN. 3) Insulated grounded conductor. 4) Plastic binder tape. 5) Interlocked aluminum armor. Branch, feeder and service power distributions in industrial, commercial and residential buildings. For power, lighting, control and signal circuits in general. Applications where maximum security is required as hazardous locations Class I Div. 2, Class II Div. 2 and Class III Div. I. 600 volts Dry Locations (THHN Type) 90 C Wet Locations (THWN Type) 75 C 1) Easy installation on exposed or concealed installations. 2) Aluminum interlock armor provides great Flexibility 3)The armor makes the cable resistant to impact and abrasion. 4) Type THHN/THWN offers: High resistance to heat and moisture. Good resistance to gasoline and oil. Flame retardance 5) Insulated ground (green) is same construction as conductors. 4) Conductor color code: 2 Conductor: black / white 3 Conductor: black / white / red 4 Conductor: black / white / red / blue Size Number of Nominal Nominal Allowable Net AWG Type Conductors Diameter Diameter Ampacity Weight AWG Under Armor Over Armor 90 C lb/mft 14 Solid Solid Solid Solid Solid Solid Solid Solid Solid Stranded Stranded Stranded Stranded Stranded Stranded Armored Cable Type MC Cable meets or excides all applicable ASTM Specifications, UL standards for safety: UL-1569 UL-1581 UL-83 Metal Clad Cable File E T.M. T.M. MC Armalat Vinilat Nylon Cable Type THHN/THWN, gauge and length

5 THHN or THWN VOLTS (MTW STRANDED) 1) Type THHN or THWN-2 Annealed bare solid (14-10 AWG), type THHN or THWN-2 Annealed bare stranded class C concentric round (14-2 AWG), compressed stranding class B (1 AWG-1000MCM)copper conductor. 2) Polyvinyl chloride (PVC insulation) 3) Nylon overall protective jacket General use in commercial and industrial construction, and installations where resistance against oils and gasoline is required. May be used for power and control circuits in recognized raceways, in wet or dry locations, and in presence of gases, gasoline and chemicals. Also suitable as machine tool and switchboard wiring. 600 volts Dry locations (THHN) Dry and wet locations (THWN-2) In oil (Oil resistant II) 90 C 90 C 75 C 1) Good resistance to moisture, heat, oil, gasoline, chemicals and grease. 2) Suitable for installation where thermal overload exists. 3) Strict quality control during manufacturing process. 4) Flame retardant, UL listed as VW-1. 5) Smooth nylon jacket aids in easier pulling. 6) Superior abrasion and mechanical properties. 7) Sizes 1/0 and larger are marked "For CT use", and are approved for installation in cable trays. Sunlight resistant in Accordance with NEC Article 318, IEEE 1202 and ULFT4 Flame Test UL-83 VINILAT Nylon, solid or stranded type THHN or THWN-2, 600 volts, size, color and length NATIONAL ELECTRICAL CODE REFERENCE Ampacities Conduit fill tables Switchboard wiring CESMEC E Article Article 384 Chapter 9 Size Number Conductor Conductor Insulation Jacket Overall AWG/ of Area Diameter Thickness Thickness Diameter kcmil Strands kcmil mils mils mils inch 14 1 Solid Solid Solid / / / / Net Weight lb/mft

6 POWER CABLE TYPE TC XHHW VOLTS 1) Annealed bare Class C concentric strand copper conductors. 2) Flame retardant XLPE. 3) Binder tape over core. 4) Overall flame retardant PVC jacket Condumex Type TC cable may be used for power, lighting, control, signal and communcation circuits, in raceways, direct burial in earth, or in messenger. Type TC cable may be used in wet or dry locations and in the presence of oil and most chemicals in accordance with the National Electrical Code 600 volts Wet or Dry Dry 90 C 90 C 1) UL listed for direct burial. 2) Flame retardant, (passes UL 1277, 70,000 BTU flame test. 3) Sunlight resistant; can be installed outdoors. 4) UL listed as Type TC for power and control tray cable used in accordance with the National Electrical Code. O 5) PVC jacket is UL rated 90 C and listed Oil Resistant I. 6) Acceptable for Class I, Division 2, Hazardous Location Applications. 7) Circuit identification; color coded per ICEA S (table E-2 or Method S/B 4.) 7a) Other color coding methods are available, based on ICEA S ) ER Listed per UL 1277 UL 1277, UL 44 Condumex Tray Cable Type TC/XHHW-2, 600 volts, number and size of conductors. Size Number Number Jacket Overall Net AWG of of Thickness Diameter Weight Strands Conductors mils inches lb/mft *Contact factory for items not shown above

7 POWER CABLE TYPE TC THHN/THWN 600 VOLTS 1) Annealed bare Class C concentric strand copper conductors. 2) Polyvinyl Chloride (PVC) thermoplastic insulation. 3) Nylon protective covering. 4) Binder tape over core. 5) Overall flame retardant PVC jacket Condumex Type TC cable may be used for power, lighting, control, signal and communcation circuits, in raceways, direct burial in earth, or in messenger. Type TC cable may be used in wet or dry locations and in the presence of oil and most chemicals in accordance with the National Electrical Code 600 volts Wet or Dry Dry 75 C 90 C 1) UL listed for direct burial. 2) Flame retardant, (passes UL 1277, 70,000 BTU flame test. 3) Sunlight resistant; can be installed outdoors. 4) UL listed as Type TC for power and control tray cable used in accordance with the National Electrical Code. O 5) PVC jacket is UL rated 90 C and listed Oil Resistant I. 6) Acceptable for Class I, Division 2, Hazardous Location Applications. Type TX offers substantial cost savings over the previously required metallic sheathed cables. 7) Circuit identification; color coded per ICEA S (table E-2 or Method S/B 4.) 7a) Other color coding methods are available, based on ICEA S ) ER Listed per UL 1277 UL 1277, UL 83 and ER Approved Condumex Tray Cable Type TC/THHN, 600 volts, number and size of conductors. Size Number Number Jacket Overall Net AWG of of Thickness Diameter Weight Strands Conductors mils inches lb/mft

8 POWER CABLE TYPE TC THHN/THWN 600 VOLTS 1) Annealed bare Class C (8-2 AWG) compressed stranded Class B (1/0 AWG- 750 kcmil) copper conductors. 2) Polyvinyl Chloride thermoplastic insulation 3) Nylon protective covering. 4) Fillers 5) Binder tape over core 6) Overall flame retardant PVC jacket. Condumex Type TC cable may be used for power, lighting, control, signal and communication circuits, in raceways, direct cable may be used in wet or dry locations and in the presence of oil and most chemicals in accordance with the National Electrical Code. 600 volts Wet or Dry Dry 75 C 90 C 1) UL listed for direct burial. 2) Flame retardant, (passes UL 1277, 70,000 BTU flame test.) 3) Sunlight resistant; can be installed outdoors. 4) UL listed as Type TC for power and control tray cable use in accordance with the National Electrical Code. 5) PVC jacket is UL rated 90 C and listed Oil Resistant I. 6) Acceptable for Class I, Division 2, Hazardous Location Applications. Type TC offers substantial cost savings over the previously required metallic sheathed cables. 7) Circuit identification; color coded per ICEA S (table E-2 or Method S/B 4.) 7a) Other color coding methods are available, based on ICEA S ) ER Listed per UL Size Number Ground Insulation Jacket Overall Net of Conductor Thickness Thickness Diameter Weight AWG/kcmil Conductors AWG mils mils inch lb/mft / / / / / / / / / / / / / / / / / / / / / / / / / / UL 1277, UL 83 and ER Approved Condumex Tray Cable Type TC/THHN, 600 volts, number and size of conductors

9 VULCANEL MEDIUM VOLTAGE XLPE OR EPR NON-SHIELDED WET OR DRY POWER CABLE 5 KV 1) Annealed bare stranded class B compact copper conductor. 2) Extruded semiconducting strand shield. 3) Ethylene propylene (EPR) or cross-linked polyethylene (XLPE) insulation. 4) Polyvinyl chloride (PVC) protective jacket VULCANEL 5kv Non-shielded power cables are ideally suited for use in industrial and utility applications where shields cannot be adequate for proper termination of the shielding. Normal Operation 105 C Emergency Overload 130 C Short Circuit 250 C 1) Simultaneous extrusion of strand shield, insulation and insulation shield (triple extrusion) results in a virtually perfect cable core. 2) XLPE insulation offers: - Low moisture absorption. - Good resistance to chemicals. - Very low dielectric loss EPR insulation offers: - Excellent heat, moisture and corona resistance. - Electrical stability under stress - Low dielectric loss - Chemical resistance 3) Easy-stripping insulation shield 4) The external PVC jacket is resistant to abrasion, ozone and moisture. 5) UL listed as MV-105, sunlight resistant, direct burial. Optional marking "For CT use" available on single conductor in accordance with the National Electrical Code. Size Number Conductor Insulation Insulation Jacket Overall Net Weight AWG/ of Diameter Thickness Diameter Thickness Diameter Lb/Mft kcmil Strands inch inch inch mils Inch XLPE EPR 5kV 133% Insulation Level, 115 mils Insulation Thickness / / / / ICEA S , AEIC CS-6-87 (EPR) ICEA S , AEIC CS-S (XLP) UL 1072 VULCANEL EPR/XLPE Non-Shielded power cable, voltage and insulation level, conductor size and type, length and reel dimensions. National Electrical Code References: Ampacities Cable Trays Type MV Page 1 of

10 VULCANEL MEDIUM VOLTAGE XLPE OR EPR NON-SHIELDED WET OR DRY POWER CABLE 5 KV Size Number Conductor Insulation Insulation Jacket Overall Net Weight AWG/ of Diameter Thickness Diameter Thickness Diameter lb/mft kcmil Strands inch inch inch mils Inch XLPE EPR 15kV 133% Insulation Level, 220 mils Insulation Thickness / / / / kV 100% Insulation Level, 260 mils Insulation Thickness / / / / kV 100% Insulation Level, 345 mils Insulation Thickness / / / / Page 2 of

11 VULCANEL MEDIUM VOLTAGE EPR SHIELDED POWER CABLES 5, 15, 25, 35 KV 1) Annealed bare stranded class B compact copper conductor. 2) Extruded semiconducting strand shield. 3) Ethylene propylene rubber (EPR) insulation. 4) Extruded semiconducting insulation shield. 5) Annealed copper tape shield (25% overlap minimum). 6) Polyvinyl chloride (PVC) protective jacket. Three-phase electrical distribution systems. Suitable for use in overhead installations, recognized raceways, direct burial or cable trays. Normal Operation 105 C Emergency Overload 130 C Short Circuit 250 C 1) Simultaneous extrusion of strand shield, insulation and insulation shield (triple extrusion) results in a virtually perfect cable core. 2) EPR insulation offers: - Excellent heat, moisture and corona resistance. - Electrical stability under stress - Low dielectric loss - Chemical resistance 3) Easy-stripping insulation shield 4) Tape shield provides high short circuit capabilities and uniform shield impedance. 5) The external PVC jacket is resistant to abrasion, ozone and moisture. 6) UL listed as MV-105, sunlight resistant, direct burial. Optional marking "For CT use" available on single conductor in accordance with the National Electrical Code. ICEA S , AEIC CS6-87 UL 1072 VULCANEL EPR shielded power cable, voltage and insulation level, conductor size and type, length and reel dimensions. National Electrical Code References: Ampacities Cable Trays 318 Type MV Size Number Conductor Insulation Insul. Shld. Jacket Overall Net of Diameter Thickness Diameter Thickness Diameter Weight AWG/kcmil Strands Inch inch inch mils Inch lb/mft 5kV 133% Insulation Level, 115 mils Insulation Thickness / / / / kV 100% Insulation Level, 175 mils Insulation Thickness / / / / Page 1 of

12 VULCANEL MEDIUM VOLTAGE EPR SHIELDED POWER CABLES 5, 15, 25, 35 KV Size Number Conductor Insulation Insul. Shld. Jacket Overall Net AWG/kcmil of Diameter Thickness Diameter Thickness Diameter Weight Strands Inch inch inch mils Inch lb/mft 15kV 133% Insulation Level, 220 mils Insulation Thickness / / / / kV 100% Insulation Level, 260 mils Insulation Thickness 1/ / / / kV 100% Insulation Level, 345 mils Insulation Thickness 1/ / / / Page 2 of 2

13 1) Three flexible annealed tinned copper rope-lay stranded conductors. 2) Extruded semi-conducting conductor shield and ethylene propylene rubber (EPR) insulation. 3) Color coded cotton/copper braid shield applied over semi-conducting tape. 4) Two annealed tinned copper rope-lay stranded grounding conductors. 5) Annealed tinned copper rope-lay stranded ground check conductor, yellow EPR insulation and covered with a yellow cotton braid. 6) Rubberized cotton binder tape. 7) Nylon web reinforced extra-heavy-duty chlorinated polyethylene (CPE) jacket. Trailing cable on ac mining equipment where service conditions are severe and maximum safety is mandatory, such as power shovels and draglines in open-pit mines, quarries, gantry cranes and slag reclaiming. Also used for medium voltage distribution in underground mines where frequent relocation is necessary. 5,000 volts Normal continuous 90 C Overload 130 C Short circuit 250 C 1) Special tinned copper stranded conductors designed for flexibility and resistance to fatigue resulting from bending and flexing. 2) Ground check conductor facilitates fail-safe ground monitoring for maximum safety. 3) EPR insulation offers excellent heat and moisture resistance, outstanding corona resistance, high dielectric strength and chemical resistance. 4) Prevulcanized thermosetting non-wicking fillers are used if necessary to obtain a substantially round configuration. 5) CV-Cured extra-heavy-duty CPE, reinforced with a nylon webbing, provides a tough, defense mechanical resistant jacket. 6) Acceptance No. P MSHA by Mines Safety and Health Administration Approval No. P MSHA by the Pennsylvania Department of Environmental Resources. Meets MSHA flame test requirements. ICEA-S Condumex Mining Cable EPR type SHD-GC three conductor cable, voltage size and length. MINING CABLE EPR TYPE SHD-GC THREE CONDUCTOR 5000 VOLTS 6 7x30/ x47/ x74/ x37/ /0 7x47/ /0 7x60/ /0 7x75/ /0 19x35/ x49/ / x58/ / SHD-GC.01 Size Number of Conductor Insulation Ground Ground Overall AWG/ Strands Diameter Thickness Size Check Size Diameter kcmil /AWG inch mils AWG AWG inch Net Weight lb/mft

14 POWER CABLE TYPE TC XHHW 600 VOLTS 1) Annealed bare stranded compressed Class B copper conductors. 2) Cross-Linked polyethylene, thermosetting XLP insulation. 3) Fillers (if required) 4) Binder tape over core. 5) Overall flame retardant PVC jacket. Condumex Type TC cable may be used for power, lighting, control, signal and communication circuits, in cable trays, raceways, direct burial, or on messenger. Type TC cable may be used in wet or dry locations and in the presence of oil and most chemicals in accordance with the National Electrical Code. 600 volts O Normal 90 C O Overload 130 C 1) UL listed for direct burial. 2) Flame retardant, (passes UL ,000 BTU flame test.) 3) Sunlight resistant; can be installed outdoors. 4) UL listed as Type TC for power and control tray cable, use in accordance with the National Electrical Code. O 5) PVC jacket is UL rated 90 C and listed Oil Resistant I. 6) Acceptable for Class 1, Division 2, Hazardous Locations applications. 7) ER Listed per UL 1277 UL-1277 & UL-44 Condumex Tray Cable Type TC/XHHW, 600 Volts number and size of conductors, with or without grounding conductor Size Number Ground Insulation Jacket Overall Net AWG/kcmil of Conductor Thickness Thickness Diameter Weight Conductors AWG mils mils inch lb/mft / ,428 2/ ,735 3/ ,150 4/ , , , , ,230 1/ ,825 2/ ,212 3/ ,751 4/ , , , ,

15 TYPE RHH-RHW-USE-2 COPPER XLPE 600 VOLTS 1) Annealed bare stranded class B conductor 2) Flame-retardant cross-linked polyethylene (XLPE) insualtion. May be installed in free air, all raceways or use in direct burial in industrial and commercial application. May be used as underground service entrance cable. 600 volts Type RHH Type RHW or USE 90 C Dry and damp locations 75 C Dry and wet locatinons 1) Flame retardant, moisture and heat resistant insulation. 2) UL listed as types RHH or RHW or USE for use in accordance with the National Electrical Code. 3) UL approved as VW-1 (RHH or RHW) 4) Good resistance to most oils and chemicals. 5) Suitable for installation in sub-zero temperatures. 6) Stable electrical propoerties. 7) Extremely tough. Size Number Conductor Conductor Insulations Overall Net of Area Diameter Thickness Diameter Weight AWG/kcmil Strands kcmil inch mils inch lb/mft / / / / UL-44 Wires and Cables. National Electrical Code References: Product Article 310, Table Ampacities Article Standard for Rubber-Insulated ICEA S Standard for Cross-Linked Polyethylene Insualted Wire and Cable. CONDUMEX type RHH-RHW-USE-2 XLPE 600 volts, size, length, quantity, packaging

16 VULCANEL XLPE CABLE TYPE XHHW VOLTS 1) Annealed bare stranded class B concentric round (14-8 AWG) compressed (6 AWG-1000 MCM) copper conductor. 2) Cross-linked polyethylene (XLPE) insulation. 2 1 Power or control circuits in recognized raceways, in wet or dry location and in presence of oil. Also suitable as switchboard wiring. 600 volts Dry locations 90 C Wet locations 90 C Overload 130 C Short Circuit 250 C 1) Smaller overall diameter for easier pulling and greater conduit fill. 2) Good moisture resistance. 3) Good resistance to most oils and chemicals. 4) Suitable for installation in sub-zero temperatures. 5) Optical "For CT use" marking, for use in cable trays. Sunlight resistant in accordance with NEC Article ) Available in VW-1 and non VW-1 designs. UL-44 Size Number Conductor Conductor Insulations Overall Net AWG/kcmil of Area Diameter Thickness Diameter Weight Strands kcmil inch Mils inch lb/mft / / / / VULCANEL XLPE cable, type XHHW-2, 600 volts, size and length. National Electrical Code References: Ampacities Switchboard wiring Conduit fill tables * Dupont trade mark Article 310 Article 384 Chapter

17 VULCANEL S8000 XLPE CABLE XHHW or XHHW VOLTS ALUMINUM 1) Stranded compact class B AA-8000 series aluminum alloy soft conductor. 2) Separator tape 3) Cross-linked polyethylene (XLPE) insulation type XHHW or XHHW Branch-circuits and feeders conductors in low voltage for buildings, schools, auditoriums, hospitals, stadiums, museums, poultry farms, etc. Industrial and commercial buildings. For use in cable trays or raceways in wet and dry locations. 600 volts Wet and dry continuous: 90 C Overload: 130 C Short circuit: 125 C 1) Easier pulling and greater conduit fill. 2) Good moisture resistance 3) Excellent dielectrics properties 4) Continuous 90 C operating temperature in wet or dry locations. 5) Suitable for use in cable trays (1/0 AWG and greater). 6) VW-1 compliant 7) Sunlight resistant insulated compliant APPROVALS Type XHHW or XHHW-2 UL listed Type Rw90 or RWU90 upon special request Size Number Insulations Overall Net AWG/kcmil of Thickness Diameter Weight Strands Mils In Lb/Mft / / / / UL-44 Vulcanel S8000 cable type XHHW or XHHW-2, CT-SR with stranded compact class B AA series aluminum alloy soft conductor, size, length and product number. National Electrical Code References: Ampacities Switchboard wiring Conduit fill tables * Dupont trade mark Article 310 Article 384 Chapter

18 VULCANEL EPR ANTILLAMA CABLE 600 VOLTS 26.ACSR.01 1) Annealed coated or un-coated stranded class B copper conductor. 2) Ethylene propylene rubber (EPR) insulation 3) Chlorosulfonated polyethylene (Hypalon*) or chlorinated polyethylene(cpe) jacket Ideally suited for use in : Electrical generating stations. May be installed in free air, all raceways, or direct burial. Dry Locations: 90 C Dry and Wet Locations: 75 C Overload: 130 C Short Circuit: 250 C 600 Volts 1) Flame resistant. Meets or exceeds requirements of IEEE 383 flame test. 2) Deformation resistant at high temperatures. 3) Excellent Flexibility at low temperature; suitable for installation in sub-zero temperatures. 4) Extra tough, mechanically rugged composite insulation and jacket construction. 6) Resistant to most oils and chemicals. ICEA S VULCANEL EPR ANTILLAMA cable, 600 volts, size length. National Electrical Code References: Ampacities Article 31, Cable Trays Article 318 Size Number Conductor Insulation Jacket Overall Net of Diameter Thickness Thickness Diameter Weight AWG/kcmil Strands Inch mils mils inch lb/mft / / / / *Dupont trade mark

19 BARE ACSR CABLE ALUMINUM CONDUCTOR STEEL REINFORCED 26.ACSR.01 CONDUCTORS Aluminum 1350 wire concentrically laid over a solid or stranded galvanized steel core. Overhead transmission, subtransmission and distribution systems. Static wires to protect overhead lines. Messenger cables to support overhead electrical cables. Messenger and power support conductor in catenary systems for railroad electrification. Normal Operation 75 C 1) Ideal combination of conductivity and strength to permit the longest possible spans. 2) Minimum sag between supports with fewer towers required. 3) High resistance to mechanical strength. 4) Wide variety of sizes available in long lengths to suit both electrical and Mechanical design requirements. 5) Good corrosion resistance. ASTM B232 Conductor overall ASTM B230 Aluminum wires ASTM B498 Galvanized steel class A ACSR cable, size, Aluminum Association Code Word, quantity required in weight. *Condumex can currently produce a wider range of products then what is listed. Please contact us for other items. CODE SIZE STRAND OVERALL DIAMETER NET WEIGHT RUPTURE STRENGTH WORD AWG or MCM AL/Steel Inch mm Lbs./mft kg/km lbs Turkey 6 6/ ,190.3 Swan 4 6/ ,860.8 Swallow 3 6/ ,304.0 Sparrow 2 6/ ,857.5 Robin 1 6/ ,555.0 Raven 1/0 6/ ,387.5 Quail 2/0 6/ ,310.0 Pigeon 3/0 6/ ,682.5 Penguin 4/0 6/ ,430.8 Partridge / ,317.5 Linnet / ,107.5 Oriole / ,325.0 Ibis / ,312.5 Lark / ,317.5 Hawk / ,507.5 Hen / ,850.0 Heron / ,750.0 Dove / ,725.0 Eagle / ,900.0 Duck / ,400.0 Grosbeak / ,200.0 Starling / ,350.0 Crow / ,100.0 Drake / ,500.0 Condor / ,125.0 Canary / ,337.0 Rail / ,875.0 Bluejay / ,

20 Grand Prairie, Texas

PV Solar Wiring Solutions

PV Solar Wiring Solutions Priority Solar Projects Across the US 14 DISTRIBUTION CENTERS PV Solar Wiring Solutions ON TIME ACCURATE FLEXIBLE SERVICE CUSTOM SOLUTIONS Priority Capabilities: Premier Supplier of Wire & Cable Cut to

More information

NORMAS DE REFERENCIA AEIC CS 1: ASTM B

NORMAS DE REFERENCIA AEIC CS 1: ASTM B AEIC CS 1: Especificación para Solid-Type Impregnated-Paper-Insulated Metallic Sheathed AEIC CS2: Especificación para Impregnated-Paper and Laminated Paper- Polypropylene Insulated, High- Pressure Pipe-Type

More information

WHAT MAKES ENCORE S XHHW-2 UNIQUE? Our SuperSlick Elite technology may be installed without additonal lubricant

WHAT MAKES ENCORE S XHHW-2 UNIQUE? Our SuperSlick Elite technology may be installed without additonal lubricant SSE XHHW-2/RW90 600V WHAT MAKES ENCORE S XHHW-2 UNIQUE? Our SuperSlick Elite technology may be installed without additonal lubricant and is available in all COLORS in sizes 14 AWG-1000 KCMIL for copper

More information

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072. 37-105VFD MMV-VFD Power Cable Three : kv - 15kV 133% Level Rated 90 C s (3) Soft annealed flexible stranded tinned copper per IEEE 150 Table 11. Extruded thermosetting 90 C Ethylene Propylene Rubber (EPR),

More information

SPECIFICATION FOR THHN/THWN-2/THW/THWN/TW ARROW ROUTE, FONTANA CA

SPECIFICATION FOR THHN/THWN-2/THW/THWN/TW ARROW ROUTE, FONTANA CA SPECIFICATION FOR THHN/THWN-2/THW/THWN/TW THHN/THWN-2/THW/THWN/TW Listed E-492385 / E-472248 APPLICATIONS THHN/THWN-2 building wire is primarily used for general purpose applications in conduit and cable

More information

Electrical Conductors Line

Electrical Conductors Line Electrical Conductors Line IUSA is present in Mexico, Europe, Asia, the US, Central and South America. Established in 1939. Workforce of over 12,000 employees. Manufacturing facilities established in Mexico

More information

America s Wire Company

America s Wire Company America s Wire Company Dear Customer, We re pleased to provide you with our latest product catalog featuring many cables stocked in our warehouse located in Austin, Texas plus a backup inventory of products

More information

Una e mpre sa Vi akab l e GLOSSARY.

Una e mpre sa Vi akab l e GLOSSARY. GLOSSARY www.centelsa.com.co CONDUCTORS Cu Copper conductors. CuSn Tinned copper conductor. ACDSR Rectangular soft bare copper wire. ACDSRP Paper insulated rectangular soft bare copper wire. ACDD Bare

More information

Glossary Of Terms M-1

Glossary Of Terms M-1 Glossary Of Terms ANSI - American National Standards Institute. Armor - A sheath, serving, braid or other layer of metal applied over a cable to increase its mechanical protection. ARR - Association of

More information

SECTION WIRE, CABLE AND BUSWAYS. A. This section specifies providing wire, cable and busways.

SECTION WIRE, CABLE AND BUSWAYS. A. This section specifies providing wire, cable and busways. SECTION 16120 WIRE, CABLE AND BUSWAYS PART 1 - GENERAL 1.01 DESCRIPTION: A. This section specifies providing wire, cable and busways. B. Definitions: 1. Cable: Cable having low smoke generating characteristics.

More information

600 VOLT 600V, 3 CONDUCTOR (WITH GROUND), FR-EPR OR FR-XLPE INSULATION, PVC JACKET SPECIFICATIONS (FLAME RETARDANT POWER CABLE) (UL TYPE TC-ER) TYPE C3 SPEC 70.0100 PROJECT 196116 REFERENCE: LATEST EDITIONS

More information

SECTION INSULATED WIRE AND CABLE

SECTION INSULATED WIRE AND CABLE SECTION 16120 INSULATED WIRE AND CABLE PART 1 GENERAL 1.01 DESCRIPTION A. This section covers the contract item Insulated Wire and Cable, which includes the following items with accessories, and appurtenances:

More information

1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods for Electrical Wires and Cables.

1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods for Electrical Wires and Cables. Issued 2005/06/01 Section 16122 Wire and Cables (0 1000V) Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 16151 Wire and Box Connectors 0 1000 1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-26 05 19.10 10 (May 2016) ----------------------------------- Preparing Activity: USACE Superseding UFGS-26 05 19.00 10 (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

SOUTH CAROLINA ELECTRIC COOPERATIVES' PRIMARY UNDERGROUND POWER CABLE SPECIFICATION

SOUTH CAROLINA ELECTRIC COOPERATIVES' PRIMARY UNDERGROUND POWER CABLE SPECIFICATION SOUTH CAROLINA ELECTRIC COOPERATIVES' PRIMARY UNDERGROUND POWER CABLE SPECIFICATION 1.0 SCOPE 1.1 This specification covers the construction, mechanical, and electrical requirements of single conductor,

More information

SECTION MEDIUM-VOLTAGE CABLES PART 1 GENERAL

SECTION MEDIUM-VOLTAGE CABLES PART 1 GENERAL SECTION 260513 - MEDIUM-VOLTAGE CABLES PART 1 GENERAL 1.1 SECTION INCLUDES A. Medium voltage cable. B. Cable terminations. C. This specification describes single conductor EPR (Ethylene-propylene-rubber)

More information

PRODUCT SELECTION LOCATOR

PRODUCT SELECTION LOCATOR PRODUCT SELECTION LOCATOR SECTION SPECIFICATION 1 300V Instrumentation Cables 1000 2 600V Instrumentation Cables 2000 3 600V Flexible Control and Power Cables 3000 4 600V Multi Conductor Control and Power

More information

Standard of Practice - Campus Electrical Distribution System

Standard of Practice - Campus Electrical Distribution System A26.3 Standard of Practice - Campus Electrical Distribution System NOTE: Significant revisions or additions to the previous standards are highlighted in italics. GENERAL Designers shall verify that all

More information

*** Supercedes: BECO E and COM , , & ***

*** Supercedes: BECO E and COM , , & *** 7/27/09 Page 1 of 9 R5 *** Supercedes: BECO E2.9-27.4 and COM 1-0696, 2-0196, & 5-0385 *** 1.0 Scope #2 AWG to 1000 KCMIL CONCENTRIC NEUTRAL JACKETED CABLES RATED 5-35 kv These Specifications cover single

More information

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR PART 1 - GENERAL Section 26 05 15 SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR 1.1 Cable shall be 15 kv, shielded, three conductor with ground, stranded copper, with continuously welded and corrugated

More information

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor TABLE OF CONTENTS SECTION SUBJECT PAGE I. SCOPE...1 II. APPLICABLE DOCUMENTS...1 III. CONDUCTOR...2 IV. SEPARATOR...2 V. INSULATION...2 A. Physical Properties...2 B. Electrical Properties...3 C. Qualification

More information

SECTION A. ASTM B3 - Standard Specification for Soft or Annealed Copper Wire; 2013.

SECTION A. ASTM B3 - Standard Specification for Soft or Annealed Copper Wire; 2013. PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 26 0519 A. Single conductor building wire. B. Metal-clad cable. C. Wiring connectors. D. Electrical tape. E. Wire pulling lubricant. F. Cable ties. 1.2 RELATED

More information

CATALOG. WIRE and CABLE. borderstates.com

CATALOG. WIRE and CABLE. borderstates.com 2015 CATALOG WIRE and borderstates.com Table of CONTENTS Building wire... 3 THHN... 5 THW-2...8 TFFN... 9 THHN CoilPAK... 11 THHN PullPro...13 XHHW... 15 NM...18 USE-2/RHW/RHW-2...22 SER...23 SEU...24

More information

ABOUT US. 830 South West Street / Sikeston, MO / F: alanwire.com

ABOUT US. 830 South West Street / Sikeston, MO / F: alanwire.com ABOUT US Alan Wire Company began in 1974 as a small bare copper manufacturer serving the utility and electrical wholesale markets with copper grounding products. Over the last 40 years, the company has

More information

U.V resistance UL Sunlight Resistance. Flame retardant IEC

U.V resistance UL Sunlight Resistance. Flame retardant IEC Cable for underground power distribution and subtransmission. Description Application Underground power distribution and subtransmission. As transformer feeders in substations. In power plants, industrial

More information

Building Wire CARRYING YOUR ELECTRICITY

Building Wire CARRYING YOUR ELECTRICITY Building Wire CARRYING YOUR ELECTRICITY Our Commitment Our commitment to our customers is simple - we deliver even when others can t. As one of Canada s largest wire, cable and data communication distributors

More information

BASIC CONCEPTS IN ELECTRICAL DESIGN. Prepared by Engr. John Paul Timola

BASIC CONCEPTS IN ELECTRICAL DESIGN. Prepared by Engr. John Paul Timola BASIC CONCEPTS IN ELECTRICAL DESIGN Prepared by Engr. John Paul Timola ELECTRICAL CONDUCTORS AND INSULATORS Electrical Conductors substances that offer a very low resistance to current flow. Insulators

More information

3 MODIFICATIONS TO EXISTING STANDARDS

3 MODIFICATIONS TO EXISTING STANDARDS 1 SCOPE This specification covers the requirements for 25 kv rated single-phase primary cable with shielded concentric neutral and an insulating jacket. The cable may be used in single or multi-phase application

More information

15 kv EPR Insulated, Jacketed, URD Cable

15 kv EPR Insulated, Jacketed, URD Cable 15 kv EPR Insulated, Jacketed, URD Cable 1000 kcm Copper Conductor with Tape Shield Page 1 of 11 Table Of Contents 1 GENERAL... 3 2 STANDARDS... 3 3 APPROVED CABLE MANUFACTURERS... 3 4 REEL SPECIFICATIONS...

More information

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

The Contractor shall furnish and install all shielded power cable suitable for use on this project. Section 16122 PRIMARY POWER CABLES PART 1 GENERAL: WORK INCLUDED The Contractor shall furnish and install all shielded power cable suitable for use on this project. RELATED WORK Section 16020: Tests SUBMITTALS

More information

Evaluation of Aluminum Cable Presentation for IEEE OCS September 14, 2011 Breck Booker, Southwire

Evaluation of Aluminum Cable Presentation for IEEE OCS September 14, 2011 Breck Booker, Southwire Evaluation of Aluminum Cable Presentation for IEEE OCS September 14, 2011 Breck Booker, Southwire Today s Topics Brief Overview of Southwire In-depth Discussion on Aluminum Characteristics Discussion of

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Change History Date Description of Change Pages / Sections Modified Change Approver Initials 6/15/16 Updated division section from 16124 to 2605 - mgl44 13, removed references to other section 10/17/14

More information

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed] [6.35/11kV Copper XLPE Three-Core HDPE Sheathed] APPLICATION Mostly used as feeder electric cable for power distribution network such as power supply station, substation, switching system etc. They are

More information

STANDARD FOR EXTRUDED INSULATION POWER CABLES RATED ABOVE 46 THROUGH 345 KV. Approved by AMERICAN NATIONAL STANDARDS INSTITUTE.

STANDARD FOR EXTRUDED INSULATION POWER CABLES RATED ABOVE 46 THROUGH 345 KV. Approved by AMERICAN NATIONAL STANDARDS INSTITUTE. ANSI/ICEA S-108-720-2012 STANDARD FOR EXTRUDED INSULATION POWER CABLES RATED ABOVE 46 THROUGH 345 KV Approved by AMERICAN NATIONAL STANDARDS INSTITUTE November 27, 2012 Publication # ANSI/ICEA S-108-720-2012

More information

This section applies to the design and installation relating to wire and cable systems and terminations. 16G Figure 1 16G Figure 2

This section applies to the design and installation relating to wire and cable systems and terminations. 16G Figure 1 16G Figure 2 Wire, Cable and Terminations Basis of Design This section applies to the design and installation relating to wire and cable systems and terminations. Design Criteria Medium Voltage Review and modify the

More information

26/35kV Copper XLPE Insulation Electric Cable

26/35kV Copper XLPE Insulation Electric Cable 26/35kV Copper XLPE Insulation Electric Cable Specifications 1.1~35kv XLPE insulated power cable 2.Standard: IEC,VDE,BS,UL,AS/NZS Black PVC sheath XLPE insulated armored copper power cable YJV22 YJV32

More information

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification

More information

Tele-Fonika Cable Americas

Tele-Fonika Cable Americas PUMP Cables Tele-Fonika Kable 2 TELE-FONIKA Kable S A, a privately held wire and cable manufacturer headquartered in Krakow, Poland, is one of the largest wire and cable companies in the world. TF operates

More information

Mining Products. Jacketing and Insulating Tapes Trailing Cable Splice Kits High Voltage Splice and Termination Kits Cable Repair Tape Special Items

Mining Products. Jacketing and Insulating Tapes Trailing Cable Splice Kits High Voltage Splice and Termination Kits Cable Repair Tape Special Items Jacketing and Insulating Tapes Trailing Cable Splice Kits High Voltage Splice and Termination Kits Cable Repair Tape Special Items Jacketing and Insulating Tapes Mining Products NEW PLYTUFF - F/R PVC Jacketing

More information

SECTION WIRES AND CABLES

SECTION WIRES AND CABLES SECTION 16120 - WIRES AND CABLES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Mining Products Jacketing and Insulating Tapes Trailing Cable Splice Kits High Voltage Splice and Termination Kits Cable Repair Tape Special Items Fon

Mining Products Jacketing and Insulating Tapes Trailing Cable Splice Kits High Voltage Splice and Termination Kits Cable Repair Tape Special Items Fon Jacketing and Insulating Tapes Trailing Cable Splice Kits High Voltage Splice and Termination Kits Cable Repair Tape Special Items Jacketing and Insulating Tapes NEW PLYTUFF - F/R PVC Jacketing Tape PVC

More information

TECHNICAL DATA. A REFERENCE FOR The Electrical Power Industry. www. ElectricalPartManuals. com ANDERSON POWER SYSTEMS, INC.

TECHNICAL DATA. A REFERENCE FOR The Electrical Power Industry. www. ElectricalPartManuals. com ANDERSON POWER SYSTEMS, INC. POWER SYSTEMS, INC. TECHNICAL DATA A REFERENCE FOR The Electrical Power Industry ANDERSON www. ElectricalPartManuals. com TABLE NUMBER INDEX PAGE NUMBER ANGLES 65 Aluminum Angle Conductors, Physical Properties

More information

NEMA Standards Publication No. WC ICEA Publication No. S

NEMA Standards Publication No. WC ICEA Publication No. S NEMA Standards Publication No. WC 71-1999 ICEA Publication No. S-96-659-1999 Standard for Nonshielded Cables Rated 2001-5000 Volts for use in the Distribution of Electric Energy Published by National Electrical

More information

Engineering Data for Copper and Aluminum Conductor Electrical Cables

Engineering Data for Copper and Aluminum Conductor Electrical Cables 2018 Edition Engineering Data for Copper and Aluminum Conductor Electrical Cables THE OKONITE COMPANY Okonite Cables...A higher Standard! The Okonite Company, 2018 Okonite Cables Table of Contents SECTION

More information

SECTION WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

SECTION WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring. SECTION 16120 WIRE AND CABLE PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 16112 - Raceways and Conduit. 2. 16155 - Motor Power and Control Wiring. 1.02 SYSTEM DESCRIPTION A. Performance Requirements:

More information

WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring. SECTION 16120 WIRE AND CABLE PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 16112 - Raceways and Conduit. 2. 16155 - Motor Power and Control Wiring. 1.02 SYSTEM DESCRIPTION A. Performance Requirements:

More information

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable. Spec. No. GO 5821-4361Rev.2 Issued date : July 13, 2005 Revised 1 date : April 29, 2015 Revised 2 date : February 19, 2016 Specification FOR 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated

More information

Clark Public Utilities

Clark Public Utilities Clark Public Utilities TECHNICAL SPECIFICATIONS 15KV MEDIUM VOLTAGE 1000 MCM AL URD CABLE 175 MIL EPR FEBRUARY 1994 REVISED MAY 1996 REVISED JUNE 2001 REVISED MARCH 2002 REVISED MARCH 2005 REVISED MAY

More information

SERV-RITE Wire and Cable

SERV-RITE Wire and Cable SERV-RITE SERVTEX Insulated Extension Wire Series 155 STOCKED FOR SAME DAY SHIPMENT K16/5/155 K16/7/155 E N J S K T 2-3. 20 16 14 20 stranded (7/28) 16 stranded (7/24) 14 stranded (7/22) 4. Type/Tolerance

More information

WESTERN UNDERGROUND COMMITTEE GUIDE 2.14 (2.14/01/0990)

WESTERN UNDERGROUND COMMITTEE GUIDE 2.14 (2.14/01/0990) WESTERN UNDERGROUND COMMITTEE GUIDE 2.14 (2.14/01/0990) ABRASION RESISTANT 600V CABLE NOTE: This "Guide" summarizes the opinions, recommendations, and practices of the Western Underground Committee members

More information

Flexible Conduit Systems

Flexible Conduit Systems Flexible Conduit Systems WHEN SAFETY MATTERS THERE S ONLY ONE CHOICE Complies to Australian & New Zealand Standards The Hi-Flex range of flexible conduit & fittings includes products tested to comply with

More information

Serv. Low-Voltage Cable Insulated Conductors for Overhead and Underground Distribution

Serv. Low-Voltage Cable Insulated Conductors for Overhead and Underground Distribution Serv Low-Voltage Cable Insulated Conductors for Overhead and Underground Distribution General Cable offers a complete line of insulated cable designs and sizes to meet utility requirements for exceptional

More information

NEC Ampacity Data Table (B)(2)(b) Ambient Temperature Correction Factors Based on 40 C (104 F)

NEC Ampacity Data Table (B)(2)(b) Ambient Temperature Correction Factors Based on 40 C (104 F) 05-01-2018 NEC Ampacity Data Table 310.15(B)(2)(b) Ambient Temperature Crection Facts Based on 40 C (104 F) F ambient temperatures other than 40 C (104 F), multiply the allowable ampacities specified in

More information

SECTION GROUNDING AND BONDING

SECTION GROUNDING AND BONDING SECTION 16060 PART 1 GENERAL 1.01 DESCRIPTION A. Section includes requirements for an electrical grounding system, including electrodes, grounding rods, connectors, insulators, equipment grounding and

More information

Technical Bulletin #27 Wiring for Architectural Applications

Technical Bulletin #27 Wiring for Architectural Applications 400, du Parc, Saint-Eustache, Québec Canada, J7R 0A1 Tel: +1.450.491.5671 +1.800.665.1166 Fax: +1.450.491.3788 www.heicolighting.com Technical Bulletin #27 Wiring for Architectural Applications WIRE SIZE

More information

CONSTRUCTION SPECIFICATION FOR CABLE INSTALLATION

CONSTRUCTION SPECIFICATION FOR CABLE INSTALLATION ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 604 NOVEMBER 2004 CONSTRUCTION SPECIFICATION FOR CABLE INSTALLATION TABLE OF CONTENTS 604.01 SCOPE 604.02 REFERENCES 604.03 DEFINITIONS - Not Used

More information

ANSI/NEMA WC ICEA S Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy

ANSI/NEMA WC ICEA S Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy Approved as an American National Standard ANSI Approval Date: February 23, 2009 ANSI/NEMA WC 70-2009 ICEA S-95-658-2009 Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy Published

More information

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.PROV 604 NOVEMBER 2017 CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE TABLE OF CONTENTS 604.01 SCOPE 604.02 REFERENCES 604.03 DEFINITIONS - Not Used

More information

History of Cable Systems HISTORICAL OVERVIEW OF MEDIUM & HIGH VOLTAGE CABLES. Nigel Hampton

History of Cable Systems HISTORICAL OVERVIEW OF MEDIUM & HIGH VOLTAGE CABLES. Nigel Hampton HISTORICAL OVERVIEW OF MEDIUM & HIGH VOLTAGE CABLES Nigel Hampton Copyright GTRC 2012 Objective To present the evolution of cables in time to understand the lessons from the past: the legacy problems and

More information

Welding Accessories

Welding Accessories Welding Accessories www.airliquide.ca 1-800-817-7697 Welding Accessories BLUESHIELD Welding Cables Blueshield Welding Cables: Excellent flexibility (stays flexible at -50 C) Abrasion resistant Oil, solvent

More information

Article 324: Flat Conductor Cable (FCC) 1.! Type FCC (flat conductor cable) cable wiring system is designed for installations under.

Article 324: Flat Conductor Cable (FCC) 1.! Type FCC (flat conductor cable) cable wiring system is designed for installations under. Part F: Code Book Questions Article 324: Flat Conductor Cable (FCC) 1.! Type FCC (flat conductor cable) cable wiring system is designed for installations under.! (a) tile! (c) carpet squares! (b) carpet!

More information

PILC Replacement: Getting the Lead Out

PILC Replacement: Getting the Lead Out PILC Replacement: Getting the Lead Out Spring Cincinnati, OH April 30, 2003 Page 1 PILC IS GREAT! Low Profile High Fault Current Capability on Shield High Degree of Water Blocking So why shouldn t you

More information

Liquatite. Flexible Conduit JIC. Steel Core. Type LT

Liquatite. Flexible Conduit JIC. Steel Core. Type LT Type LT JIC in. (mm) 1/4 LT025-75 75 - - - - 1.0 (25.4) 8 5/16 LT032-75 75 - - - - 1.0 (25.4) 8 3/8 LT038-30 30 LT038-150 150 LT038-300 300 1.5 (38.1) 9 1/2 LT050-30 30 LT050-150 150 LT050-300 300 2.0

More information

BLACK EPR INSULATED MEDIUM VOLTAGE CABLES. Ronald F. Frank, Eng. Consultant

BLACK EPR INSULATED MEDIUM VOLTAGE CABLES. Ronald F. Frank, Eng. Consultant 1 INTRODUCTION BLACK EPR INSULATED MEDIUM VOLTAGE CABLES Ronald F. Frank, Eng. Consultant The predecessors of black EPR were natural rubber, oil-base rubber, synthetic styrenebutadiene rubber (SBR) and

More information

STANDARD SPECIFICATION FOR SIGNAL CABLE. A. This Specification provides for single and multi-conductor insulated and jacketed cable for

STANDARD SPECIFICATION FOR SIGNAL CABLE. A. This Specification provides for single and multi-conductor insulated and jacketed cable for STANDARD SPECIFICATION FOR SIGNAL CABLE 1.01 SCOPE A. This Specification provides for single and multi-conductor insulated and jacketed cable for installation in direct contact with the earth, in ducts,

More information

Article-No. Type. All dimensions in mm. Subject to technical changes. Other dimensions, reel lengths or colours available on request.

Article-No. Type. All dimensions in mm. Subject to technical changes. Other dimensions, reel lengths or colours available on request. 4.4 Installation Devices HelaTape HellermannTyton offers a wide range of PVC and rubber tapes for sealing, insulation and bundling of cable and conduits. PVC based tapes are designed for low voltage applications

More information

ANNEX B: APPLICATION INFORMATION FOR AMPACITY CALCULATION ITEMS B (B)(1) THROUGH B (B)(7)

ANNEX B: APPLICATION INFORMATION FOR AMPACITY CALCULATION ITEMS B (B)(1) THROUGH B (B)(7) ITEMS B.0.5(B)() THROUGH B.0.5(B)(7) B.0.5(B)() EQUATION APPLICATION INFORMATION This informative annex provides application information for ampacities calculated under engineering supervision. B.0.5(B)()

More information

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 604 NOVEMBER 2008 CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE TABLE OF CONTENTS 604.01 SCOPE 604.02 REFERENCES 604.03 DEFINITIONS - Not Used

More information

Power Systems 2 ELE3015. Lecture 1: Transmission Lines

Power Systems 2 ELE3015. Lecture 1: Transmission Lines Power Systems 2 ELE3015 Lecture 1: Transmission Lines Transmission Lines: Introduction Use to carry electrical power from point of generation to the point of use. Usually over large distances. Made with

More information

TECHNICAL ANALYSIS #2

TECHNICAL ANALYSIS #2 TECHNICAL ANALYSIS #2 Problem Civista is wired using copper conductors only. Copper is an expensive material that is some opinions, offers the same performance from a much cheaper aluminum alloy alternative.

More information

Heavy Wall Heat Shrinkable Tubing 5-7. Flame Retardant Heavy Wall Heat Shrinkable Tubing 8. Heat Shrinkable Ends Caps 9

Heavy Wall Heat Shrinkable Tubing 5-7. Flame Retardant Heavy Wall Heat Shrinkable Tubing 8. Heat Shrinkable Ends Caps 9 Heavy Wall Heat Shrinkable Tubing 5-7 Flame Retardant Heavy Wall Heat Shrinkable Tubing 8 Heat Shrinkable Ends Caps 9 Heat Shrinkable Breakout Boots 10 Shrink Ratio 3:1 Shrink-Kon Heavy Wall Heat Shrinkable

More information

JAMES MONROE. WIRE & CABLE CORPORATION ETT Traveling Cable Hoistway Cable Compensating Cable Stationary Communications Cable ELEVATOR CABLES

JAMES MONROE. WIRE & CABLE CORPORATION ETT Traveling Cable Hoistway Cable Compensating Cable Stationary Communications Cable ELEVATOR CABLES WIRE & CABLE CORPORATION ETT Traveling Cable Hoistway Cable Compensating Cable Stationary Communications Cable ELEVATOR CABLES Elevator Hoistway & Traveling Cables... Designed for high performance and

More information

SECTION GROUNDING

SECTION GROUNDING SECTION 16450 GROUNDING PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies general grounding and bonding requirements of electrical and telecommunication installations for personnel safety, equipment

More information

Anaconda SEALTITE. When you say SEALTITE, there is only one: ANACONDA. Index FLEXIBLE CONDUIT TYPES 4-5. ANAMET Electrical, Inc.

Anaconda SEALTITE. When you say SEALTITE, there is only one: ANACONDA. Index FLEXIBLE CONDUIT TYPES 4-5. ANAMET Electrical, Inc. When you say SEALTITE, there is only one: ANACONDA. Index FLEXIBLE CONDUIT TYPES 4-5 Type UA Type CNP UA 6 EFST 7 EF 8 HTUA 9 HC 10 HCX 11 ZHUA 13 CW 14 OR 15 EFL 16 MTC 17 STAINLESS STEEL CONNECTORS 18

More information

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE TI 20 PVC TI 20 INSULATED TELEPHONE WIRE Standard: Nominal voltage: Temperature range - fixed laying: Cable Structure: Application: Packing: 2x0,5 0,4 2,6 3,6 7,2 2x0,6 0,4 2,8 5,2 9,1 2x0,8 0,4 3,2 9,2

More information

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV) EDC3 (5239) P3 Mini-Grid Systems DRAFT TANZANIA STANDARD Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV) TANZANIA BUREAU OF STANDARDS TBS 2017 First Edition 2017 Table of Contents

More information

SPECIFICATION FOR 600 VOLT CONTROL AND POWER CABLE SPECIFICATION NO. 557

SPECIFICATION FOR 600 VOLT CONTROL AND POWER CABLE SPECIFICATION NO. 557 EXHIBIT A - TECHNICAL SPECIFICATION SPECIFICATION FOR 600 VOLT CONTROL AND POWER CABLE SPECIFICATION NO. 557 DATE: March 31, 2000 (REVISED: October 13, 2006) (REVISED: February 14, 2012) (REVISED: January

More information

MATERIAL STANDARD FOR CABLES AND WIRES

MATERIAL STANDARD FOR CABLES AND WIRES MATERIAL STANDARD FOR CABLES AND WIRES CONTENTS : PAGE No. 1. SCOPE... 2 2. SERVICE CONDITIONS... 2 3. REFERENCES AND STANDARDS... 2 4. UNITS... 3 5. CABLE DESIGN AND CONSTRUCTION... 3 5.1 Applicable Cable

More information

ANSI/NEMA WC ICEA S Standard for Control, Thermocouple Extension, and Instrumentation Cables

ANSI/NEMA WC ICEA S Standard for Control, Thermocouple Extension, and Instrumentation Cables Approved as an American National Standard ANSI Approval Date: October 31, 2014 ANSI/NEMA WC 57-2014 ICEA S-73-532-2014 Standard for Control, Thermocouple Extension, and Instrumentation Cables Prepared

More information

Your Partner for Custom Interconnectivity Solutions. ISO 9001 AS9100C ISO ISO Qualified

Your Partner for Custom Interconnectivity Solutions. ISO 9001 AS9100C ISO ISO Qualified Your Partner for Custom Interconnectivity Solutions ISO 9001 AS9100C ISO 13485 ISO 17025 Qualified LEMO Precision Custom Connection Solutions The Original Push-Pull Connector Seven Decades of Expertise

More information

STANDARD FOR CONCENTRIC NEUTRAL CABLES RATED 5 THROUGH 46 KV

STANDARD FOR CONCENTRIC NEUTRAL CABLES RATED 5 THROUGH 46 KV ANSI/ICEA S-94-649-2013 STANDARD FOR CONCENTRIC NEUTRAL CABLES RATED 5 THROUGH 46 KV Approved by AMERICAN NATIONAL STANDARDS INSTITUTE March 19,2013 Publication # ANSI/ICEA S-94-649-2013 2013 by INSULATED

More information

QUALIFICATION UPDATE. Eric Rasmussen. Quality Cables Since 1854

QUALIFICATION UPDATE. Eric Rasmussen. Quality Cables Since 1854 QUALIFICATION UPDATE Eric Rasmussen Quality Cables Since 1854 90 C 60 year Four successful qualifications to date: QR-1305: Kerite Shielded MV Power Cables for 60 Year Life at 90 C (LOCA) QR-1403: Kerite

More information

POLYMERIC ARMOR DESIGN OF AN IMPROVED PROTECTION TO MECHANICAL STRESSES AND FLUIDS FOR OIL GAS AND PETROCHEM (OGP) APPLICATIONS

POLYMERIC ARMOR DESIGN OF AN IMPROVED PROTECTION TO MECHANICAL STRESSES AND FLUIDS FOR OIL GAS AND PETROCHEM (OGP) APPLICATIONS POLYMERIC ARMOR DESIGN OF AN IMPROVED PROTECTION TO MECHANICAL STRESSES AND FLUIDS FOR OIL GAS AND PETROCHEM (OGP) APPLICATIONS Paul CINQUEMANI, Prysmian Cables & Systems USA, LLC, paul.cinquemani@prysmian.com

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 260526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract apply to this Section. 1.2 SUMMARY A. This Section

More information

PVC Insulating Tape. Electrical Tapes

PVC Insulating Tape. Electrical Tapes Electrical Tapes 7 Electrical Tapes Electrical Tapes 3M offer a range of over 30 electrical tapes and mastics for insulation, jointing, corrosion protection, all weather protection and environmental sealing.

More information

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath 0.6/1 kv LOW VOLTAGE CONTROL CABLES PVC OR XLPE INSULATED, PVC SHEATHED AS PER IEC 60502-1 Conductors Conductors shall be Circular Stranded, Class 2 as per IEC 60228, BS EN 60228. Upon request, Solid Circular

More information

EHV XLPE CABLES CDCC LINE

EHV XLPE CABLES CDCC LINE PROFILE THE HINDUSTHAN VIDYUT PRODUCTS LIMITED, established in the year 1959 is a leading manufacturer of Overhead Conductors and Underground Cables. The Company at its Faridabad Works has sophisticated

More information

Your Partner for Custom Interconnectivity Solutions. ISO 9001 AS9100C ISO ISO Qualified

Your Partner for Custom Interconnectivity Solutions. ISO 9001 AS9100C ISO ISO Qualified Your Partner for Custom Interconnectivity Solutions ISO 9001 AS9100C ISO 13485 ISO 17025 Qualified LEMO Precision Custom Connection Solutions The Original Push-Pull Connector Seven Decades of Expertise

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. AFC Cable Systems, Inc. Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519.13 METAL CLAD CABLE-MC

More information

SPECIFICATION FOR FRLS POWER CABLES

SPECIFICATION FOR FRLS POWER CABLES SPECIFICATION FOR FRLS POWER CABLES 1.0 SCOPE This specification cover the technical requirements of design, manufacture, testing and delivery to site of Power Cables of 1100V grade with FRLS PVC Sheathed,

More information

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 DESCRIPTION SECTION 28 05 26 GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY SPEC WRITER NOTE: Delete // // if not applicable to project. Also delete any other item or paragraph

More information

New Conduit Specification

New Conduit Specification New Conduit Specification Combines Portions of Sections 715, 783 & 992 into New Section 630. Coordinated Effort Between Traffic Operations, ITS, Lighting, Construction, and Industry New Conduit Specification

More information

SECTION 7.3 TECHNICAL SPECIFICATION OF POWER CABLES & CONDUCTOR

SECTION 7.3 TECHNICAL SPECIFICATION OF POWER CABLES & CONDUCTOR SECTION 7.3 TECHNICAL SPECIFICATION OF POWER CABLES & CONDUCTOR 458 7.3.1 11 KV Cables 7.3.1.1 General Where a Manufacturer s Standard or a national Standard equal to or better than the appropriate specified

More information

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 23, 2018

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 23, 2018 STANDARDS UPDATE NOTICE (SUN) ISSUED: February 23, 2018 STANDARD INFORMATION Standard Number: UL 83 / CSA C22.2 No 75 / NMX-J-010-ANCE Standard Name: Thermoplastic-Insulated Wires and Cables Standard Edition

More information

OFFSHORE CABLES NEK 606 : with FIREBAR the TOTAL SAFETY fire and water resistant cable

OFFSHORE CABLES NEK 606 : with FIREBAR the TOTAL SAFETY fire and water resistant cable OFFSHORE CABLES NEK 606 : 2016 with FIREBAR the TOTAL SAFETY fire and water resistant cable System certifications CCI Quality CCI Evironmental CCI Evironmental CCI Health & Safety CABLE SERVICE Quality

More information

DIVISION 26 ELECTRICAL Electrical Power Conductors and Cables

DIVISION 26 ELECTRICAL Electrical Power Conductors and Cables PART 1 - GENERAL 1.01 DESIGN REQUIREMENTS A. Scope: Power Conductors and Cables in this section are defined as system voltages above 120V and less than 600V. B. System Voltages Three Phase and Single Phase:

More information

Electrical Conductors

Electrical Conductors Electrical Conductors Course No: E02-005 Credit: 2 PDH A. Bhatia Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800 F: (877) 322-4774 info@cedengineering.com

More information

OKLAHOMA DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR BRIDGE NAVIGATION LIGHTING

OKLAHOMA DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR BRIDGE NAVIGATION LIGHTING 809-1(a-e) 09 OKLAHOMA DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR BRIDGE NAVIGATION LIGHTING These special provisions amend and where in conflict, supersede applicable sections of the 2009 Standard

More information