16.4 FLORIDA BUILDING CODE BUILDING

Size: px
Start display at page:

Download "16.4 FLORIDA BUILDING CODE BUILDING"

Transcription

1 Designs using NAAMM FP-1001 Specification for Design Loads of Metal Flagpoles. 6. Subject to the limitations of , , and , the provisions of the FC&PA Guide to Concrete Masonry Residential Construction in High Wind Areas shall be permitted for applicable concrete masonry buildings of Group R3 occupancy for a basic wind speed of 130 mph (58 m/s) or less in Exposure B and 110 mph (49 m/s) or less in Exposure C in accordance with Figure 1606 and Section ANSI/TIA/EIA 222 shall be permitted for communication tower and steel antenna support structures and shall meet the wind loads of ASCE 7 and shall be designed by a qualified engineer. 8. Subject to the limitations of , , and , the provisions of the WPPC Guide to Wood Construction in High Wind Areas shall be permitted for applicable wood-frame buildings of Group R3 occupancy for a basic wind speed of 130 mph (58 m/s) or less in Exposure B and 110 mph (49 m/s) or less in Exposure C in accordance with Figure 1606 and Section SECTION 1606 WIND LOADS Applications. Buildings, structures and parts thereof shall be designed to withstand the minimum wind loads prescribed herein. Decreases in wind loads shall not be made for the effect of shielding by other structures. Wind pressures shall be assumed to come from any horizontal direction and to act normal to the surfaces considered Determination of wind forces. Wind forces on every building or structure shall be determined by the provisions of Chapter 6 of ASCE 7. Exceptions: 1. Provisions of shall be permitted for buildings 60 ft (18.3 m) high or less. 2. Wind tunnel tests together with applicable sections of Subject to the limitations of , , and , the provisions of SBCCI SSTD 10 shall be permitted for applicable Group R2 and R3 buildings for a basic wind speed of 130 mph (58 m/s) or less in Exposure B and 110 mph (49 m/s) or less in Exposure C in accordance with Figure 1606 and Section Subject to the limitations of , , and , Provisions of AF&PA Wood Frame Construction Manual for One- and Two-Family Dwellings 1995 SBC High Wind Edition 1996 shall be permitted for applicable wood framed buildings of Group R3 occupancy for a basic wind speed of 146 mph (65 m/s) or less in Exposure B and 124 mph (55 m/s) or less in Exposure C in accordance with Figure 1606 and Section Applicability. The provisions of SSTD 10, the AF&PA Wood Frame Construction Manual for One- and Two-Family Dwellings, High Wind Edition, the Guide to Concrete Masonry Residential Construction in High Wind Areas, and the WPPC Guide to Wood Construction in High Wind Areas are applicable only to buildings located within Exposure A, B or C as defined in The provisions shall not apply to buildings sited on the upper half of an isolated hill, ridge, or escarpment meeting the following conditions: 1. The hill, ridge or escarpment is 60 feet (18.3 m) or higher if located in exposure B or 30 feet (9.1 m) or higher if located in exposure C; 2. The maximum average slope of the hill exceeds 10 percent; and 3. The hill, ridge or escarpment is unobstructed upwind by other such topographic features for a distance from the high point of 50 times the height of the hill or 1 mile (1.6 km), whichever is greater Minimum wind loads. The wind loads used in the design of the main wind-force-resisting system shall not be less than 10 pounds per square foot (0.479 kn/m 2 ) multiplied by the area of the building or structure projected on a vertical plane normal to the wind direction. In the calculation of design wind loads for components and cladding for buildings, the algebraic sum of the pressures acting on opposite faces shall be taken into account. The design pressure for components and cladding of buildings shall not be less than 10 pounds per square foot (0.479 kn/m 2 ) acting in either direction normal to the surface. The design force for open buildings and other structures shall not be less than 10 pounds per square foot (0.479 kn/m 2 ) multiplied by the area A f FLORIDA BUILDING CODE BUILDING

2 TABLE Anchorage against overturning, uplift and sliding. Structural members and systems, and components and cladding in a building or structure shall be anchored to resist wind-induced overturning, uplift and sliding and to provide continuous load paths for these forces to the foundation. Where a portion of the resistance to these forces is provided by dead load, the minimum dead load likely to be in place during a design wind event shall be used Protection of openings. In windborne debris regions, exterior glazing that receives positive pressure in the lower 60 feet (18.3 m) in buildings shall be assumed to be openings unless such glazing is impact resistant or protected with an impact resistant covering meeting the requirements of SSTD 12, ASTM E 1886 and ASTM E 1996, or Miami-Dade PA 201, 202 and 203 referenced therein as follows: 1. Glazed openings located within 30 feet (9.1 m) of grade shall meet the requirements of the Large Missile Test. 2. Glazed openings located more than 30 feet (9.1 m) above grade shall meet the provisions of the Small Missile Test. Exception: Wood structural panels with a minimum thickness of 7 /16 inch (11.1 mm) and maximum panel span of 8 feet (2438 mm) shall be permitted for opening protection in one- and two-story buildings. Panels shall be precut to cover the glazed openings with attachment hardware provided. Attachments shall be designed to resist the components and cladding loads determined in accordance with Table B. Attachment in accordance with Table is permitted for buildings with mean roof height of 33 feet (10 m) or less where wind speeds do not exceed 130 mph (58 m/s) Buildings with openings. Where exterior glazing is assumed to be an opening, in accordance with , the building shall be evaluated to determine whether the openings are of sufficient area to constitute an open or partially enclosed building as defined in Open and partially enclosed buildings shall comply with the applicable provisions of ASCE The wind-borne debris regions requirements shall not apply landward of the designated contour line in Figure A geographical boundary that coincides with the contour line shall be established Definitions. The following definitions apply only to the provisions of Building, Enclosed. A building that does not comply with the requirements for open or partially enclosed buildings. Building And Other Structure, Flexible. Slender buildings and other structures that have a fundamental natural frequency less than 1 Hz. Building, Low-rise. Enclosed or partially enclosed buildings which comply with the following conditions: 1. mean roof height, h, less than or equal to 60 ft (18 m); 2. mean roof height, h, does not exceed least horizontal dimension. Building, Open. A building having each wall at least 80% open. This condition is expressed for each wall by the formula A o 0.8 A g where: A o = total area of openings in a wall that receives positive external pressure, in sq ft (m 2 ) TABLE WIND-BORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS FASTENER FASTENER SPACING (in.) 1,2 TYPE Panel Span 2 ft 2 ft < Panel Span 4 ft < Panel Span 6 ft < Panel Span < 4 ft < 6 ft < 8 ft 2 1/2 #6 Wood Screw /2 #8 Wood Screws Double-Headed Nails SI: 1 inch=25.4 mm 1 foot=305 mm Notes: 1. This table is based on a maximum wind speed of 130 mph (58 m/s) and mean roof height of 33 feet (10 m) or less. 2. Fasteners shall be installed at opposing ends of the wood structural panel. 3. Where screws are attached to masonry or masonry/stucco, they shall be attached using vibration-resistant anchors having a minimum withdrawal capacity of 490 lb (2180 kn). 4. Nails shall be 10d common or 12d box double-headed nails. FLORIDA BUILDING CODE BUILDING 16.5

3 A g = the gross area of that wall in which A o is identified, in sq ft (m 2 ) Building, Partially Enclosed. A building which complies with both of the following conditions: 1. the total area of openings in a wall that receives positive external pressure exceeds the sum of the areas of openings in the balance of the building envelope (walls and roof) by more than 10%, and 2. the total area of openings in a wall that receives positive external pressure exceeds 4 sq ft (0.37 m 2 ) or 1% of the area of that wall, whichever is smaller, and the percentage of openings in the balance of the building envelope does not exceed 20%. These conditions are expressed by the following formulas: 1. A o > 1.10A oi 2. A o > 4 sq ft (0.37 m 2 ) or > 0.01A g, whichever is smaller, and A oi /A gi 0.20 where: A o, A g are as defined for Open Building A oi = A gi = the sum of the areas of openings in the building envelope (walls and roof) not including A o, in sq ft (m 2 ) the sum of the gross surface areas of the building envelope (walls and roof) not including A g, in sq ft (m 2 ) Building, simple diaphragm: A building which complies with all of the following conditions: 1. enclosed building, 2. mean roof height, h, less than or equal to 60 ft (18 m), 3. mean roof height, h, does not exceed least horizontal dimension, 4. building has an approximately symmetrical cross section, 5. building has no expansion joints or structural separations within the building, 6. wind loads are transmitted through floor and roof diaphragms to the vertical lateral-force-resisting systems, and 7. if the building has moment-resisting frames, roof slopes do not exceed 30%. Components and Cladding. Elements of the building envelope that do not qualify as part of the main wind-force resisting system. Effective Wind Area. For component and cladding elements, the effective wind area in Tables B and C is the span length multiplied by an effective width that need not be less than one-third the span length. For cladding fasteners, the effective wind area shall not be greater than the area that is tributary to an individual fastener. Hurricane Prone Regions. Areas vulnerable to hurricanes defined as: 1. the U.S. Atlantic Ocean and Gulf of Mexico coasts where the basic wind speed is greater than 90 mph (40 m/s), and 2. Hawaii, Puerto Rico, Guam, Virgin Islands and American Samoa. Importance Factor, I. A factor that accounts for the degree of hazard to human life and damage to property. Mean Roof Height. The dimension from grade to the average of the roof eave height and the highest point on the roof surface, except that eave height shall be used for roof angle of less than or equal to 10%. Main Wind-force Resisting System. An assemblage of structural elements assigned to provide support and stability for the overall structure. The system generally receives wind loading from more than one surface. Wind-Borne Debris Region. 1. Areas within one mile (1.6 km) of the coastal mean high water line where the basic wind speed is 110 mph (49 m/s) or greater. 2. Areas where the basic wind speed is 120 mph (53 m/s) or greater except from the eastern border of Franklin County to the Florida-Alabama line where the region includes areas only within 1 mile of the coast Basic wind speed. The basic wind speed in miles per hour, for the development of wind loads, shall be determined from Figure Basic wind speed for the special wind regions indicated, near mountainous terrain and near gorges shall be in accordance with local jurisdiction requirements. The exact location of wind speed lines shall be established by local ordinance using recognized physical landmarks such as major roads, canals, rivers and lake shores, wherever possible Wind speed conversion. When referenced documents are based on fastest mile wind speeds, the three second gust wind velocities of Figure 1606 shall be converted to fastest mile wind velocities using Table TABLE EQUIVALENT BASIC WIND SPEEDS 3 sec. gust fastest mile mph = m/s Information on drawings. The following information related to wind loads shall be shown on the construction drawings: 1. Basic wind speed, mph, (m/s) FLORIDA BUILDING CODE BUILDING

4 Wind importance factor (l) and building category. 3. Wind exposure - if more than one wind exposure is used, the wind exposure and applicable wind direction shall be indicated. 4. The applicable internal pressure coefficient. 5. Components and Cladding. The design wind pressures in terms of psf (kn/m 2 ), to be used for the design of exterior component and cladding materials not specifically designed by the registered design professional Exposure Category. For each wind direction considered, an exposure category that adequately reflects the characteristics of ground surface irregularities shall be determined for the site at which the building or structure is to be constructed. For a site located in the transition zone between categories, the category resulting in the largest wind forces shall apply. Account shall be taken of variations in ground surface roughness that arise from natural topography and vegetation as well as from constructed features. For any given wind direction, the exposure in which a specific building or other structure is sited shall be assessed as being one of the following categories: 1. Exposure A. Large city centers with at least 50% of the buildings having a height in excess of 70 feet (21.3 m). Use of this exposure category shall be limited to those areas for which terrain representative of Exposure A prevails in the upwind direction for a distance of at least one-half mile (0.8 km) or 10 times the height of the building or other structure, whichever is greater. Possible channeling effects or increased velocity pressures caused by the building or structure being located in the wake of adjacent buildings shall be taken into account. 2. Exposure B. Urban and suburban areas, wooded areas, or other terrain with numerous closely spaced obstructions having the size of single-family dwellings or larger. Exposure B shall be assumed unless the site meets the definition of another type exposure. 3. Exposure C. Means, except in the high velocity hurricane zone, that area which lies within 1500 feet of the coastal construction control line, or within 1500 feet of the mean high tide line, whichever is less. On barrier islands, exposure category C shall be applicable in the coastal building zone set forth in s (5), Florida Statutes. 4. Exposure D. Flat, unobstructed areas exposed to wind flowing over open water (excluding shorelines in hurricane prone regions) for a distance of at least 1 mile (1.61 km). Shorelines in Exposure D include inland waterways, the Great Lakes and coastal areas of California, Oregon, Washington and Alaska. This exposure shall apply only to those buildings and other structures exposed to the wind coming from over the water. Exposure D extends inland from the shoreline a distance of 1500 feet (460 m) or 10 times the height of the building or structure, whichever is greater Simplified provisions for Low Rise Buildings Scope. Procedures in shall be used for determining and applying wind pressures in the design of simple diaphragm buildings with flat, hipped and gableshaped roofs having a mean roof height not exceeding the least horizontal dimension of the building or 60 ft (18.3 m), whichever is less. The provisions of shall not be used if any of the following conditions exist: 1. Buildings on which exterior glazing is considered to be openings in accordance with Buildings sited on the upper half of an isolated hill or escarpment meeting all the following conditions: 2.1 The hill or escarpment is 60 feet (18.3 m) or higher if located in exposure B or 30 feet (9.1 m) or higher if located in Exposure C. 2.2 The maximum average slope of the hill exceeds 10 percent. 2.3 The hill or escarpment is unobstructed upwind by other such topographic features for a distance from the high point of 50 times the height of the hill or 1 mile (1.6 km), whichever is less Wind pressures Structural members, cladding, fasteners and systems providing for the structural integrity of the building shall be designed for the loads from Tables A, B and C using Figure 1606, multiplied by the appropriate height and exposure coefficient from Table D and the importance factor from Table FLORIDA BUILDING CODE BUILDING 16.7

5 FIGURE 1606 FIGURE 1606 STATE OF FLORIDA WIND-BORNE DEBRIS REGION & BASIC WIND SPEED 16.8 FLORIDA BUILDING CODE BUILDING

6 TABLE TABLE 1606 IMPORTANCE FACTORS FOR BUILDINGS AND OTHER STRUCTURES Nature of Occupancy Importance Factor I w All buildings and structures except those listed below 1.0 Buildings and structures where the occupant load is 300 or more in any one room Buildings and structures designated as essential facilities, including, but not limited to: 1.15 (1) Hospital and other medical facilities having surgery or emergency treatment areas (2) Fire or rescue and police stations (3) Primary communication facilities and disaster operation centers (4) Power stations and other utilities required in an emergency Buildings and structures that represent a low hazard to human life in the event of failure, such as agricultural buildings, screen enclosures, certain temporary facilities, and minor storage facilities 0.87 a a In hurricane-prone regions with V > 100 mph (45 m/s), I w shall be Members that act as both part of the main wind-force-resisting system and as components and cladding shall be designed for each separate load case Edge strips and end zones. The width of the edge strips (a), as shown in Figure (c), shall be 10% of the least horizontal dimension or 40% of the eave height, whichever is less but not less than either 4% of the least horizontal dimension or 3 feet (914 mm). End zones as shown in Figure b shall be twice the width of the edge strip (a) Main wind force resisting system (MWFRS). All elements and connections of the MWFRS shall be designed for vertical and horizontal loads based on the combined leeward and windward wall pressures and roof pressures determined from Table A. Pressures shall be applied in accordance with the loading diagrams shown in Figure a to the end zone and interior zone as shown in Figure b. The building shall be designed for all wind directions. For buildings having flat roofs, a ridge line normal to the wind direction shall be assumed at the mid-length dimension of the roof for all directions considered. Each corner shall be considered in turn as the windward corner Overhang loads. The pressures to be used for the effects of roof overhangs on MWFRS shall be taken from Table A and include the effect of the wind on both the bottom and top surfaces Components and cladding. Pressure for wind loading actions on components and cladding shall be determined from Table1606.2B for enclosed portions of the building and Table C for overhangs, based on the effective area for the element under consideration. The pressures in Table C include internal pressure. The pressure shall be applied in accordance with the loading diagrams in Figure c Roof systems Roof deck. The roof deck shall be designed to withstand the wind pressures determined from the provisions of for buildings with a mean roof height not exceeding 60 ft (18.3 m) in height or for buildings of any height Roof coverings. Roof coverings shall comply with Rigid tile roof coverings that are air-permeable and installed over a roof deck shall be permitted to be designed in accordance with Exception: Rigid tile roof coverings that are air permeable and installed over a roof deck complying with may be designed in accordance with Rigid tile. Wind loads on rigid tile roof coverings shall be determined in accordance with the following formula: M a = q h C L bll a [1.0 - GC p ] where: M a = aerodynamic uplift moment acting to raise the tail of the tile, foot-pounds (N-mm). q h = wind velocity pressure determined from Equation 6-1 of ASCE 7 (psf). C L = The lift coefficient shall be 0.2 or shall be determined by testing in accordance with b = exposed width of the roof tile, feet (mm). L = length of the roof tile, feet (mm). L a = moment arm [feet (mm)] from the axis of rotation to the point of uplift on the roof tile. The point of uplift shall be taken at 0.76 L from the head of the tile and the middle of the exposed width. For roof tiles with nails or screws (with or without a tail clip), the axis of rotation shall be taken as the head of the tile for direct deck applications and as the top edge of the batten for battened applications. For roof tiles fastened only by a nail or screw along the side of the tile, the axis of rotation shall be determined by testing. For roof tiles installed with battens and fastened only by a clip near the tail of the tile, the moment arm shall be determined about the top edge of the batten with consideration given for the point of rotation of the tiles FLORIDA BUILDING CODE BUILDING 16.9

7 TABLE A TABLE A MAIN WIND FORCE RESISTING SYSTEM WIND LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN Exposure B Horizontal loads 2 Vertical Loads (psf) Max. Horizontal Wall Loads 4 (psf) Windward End Zone Interior Zone End Zone Interior Zone Overhang Zone Wind Roof Velocity Load angle Windward Leeward Windward Leeward End Interior (mph) Direction (degrees) Wall Roof 3 Wall Roof 3 Roof Roof Roof Roof Zone Zone 1E 4E Transverse < angle Longitudinal All angles Transverse < angle Longitudinal All Angles Transverse < angle Longitudinal All Angles Transverse < angle Longitudinal All Angles Transverse < angle Longitudinal All Angles Transverse < angle Longitudinal All Angles Transverse < angle Longitudinal All Angles For SI: 1 ft 2 = m 2, 1 mph = m/s, 1 degree of angle = rad, 1 psf = N/m 2. Notes: 1 Pressures for roof angles from 5 to 20 degrees shall be interpolated from the table. 2 Pressures are the sum of the windward and leeward pressures and shall be applied to the windward elevation of the building in accordance with Figure (c). 3 If pressure is less than 0, use 0. 4 Pressures shall be applied in accordance with Figure (b) FLORIDA BUILDING CODE BUILDING

8 TABLE B TABLE B COMPONENT AND CLADDING WIND LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (psf) Effective wind Basic Wind Speed V (mph - 3 second gust) area Zone 3 (ft 2 ) Roof Angle > 0-10 degrees Roof Angle > degrees Roof Angle > degrees Wall For SI: 1 ft 2 = m 2, 1 mph = m/s, 1 psf = N/m 2. 1 For effective areas or wind speeds between those given above the load may be interpolated, otherwise use the load associated with the lower effective area. 2 Table values shall be adjusted for height and exposure by multiplying by adjustment coefficients in Table D. 3 See Figure (c) for location of zones. 4 Plus and minus signs signify pressures acting toward and away from the building surfaces. FLORIDA BUILDING CODE BUILDING 16.11

9 TABLE C - TABLE D TABLE C ROOF OVERHANG COMPONENT AND CLADDING DESIGN WIND PRESSURES FOR A BUILDING WITH MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (psf) Basic Wind Speed v (mph - 3 second gust) Effective Wind Area Zone (ft 2 ) Roof Angle > 0-10 degrees Roof Angle > degrees Roof Angle > degrees For SI: 1 psf = N/m 2, 1 ft 2 = m 2, 1 mph = m/s. Note: For effective areas between those given above the load may be interpolated, otherwise use the load may be interpolated, otherwise use the load associated with the lower effective area. TABLE D HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS Mean Exposure Roof Height B C D Note: All table values shall be adjusted for other exposures and heights by multiplying by the above coefficients FLORIDA BUILDING CODE BUILDING

10 FIGURE a - FIGURE c FIGURE a APPLICATION OF MAIN WIND FORCE RESISTING SYSTEM LOADS FOR SIMPLE DIAPHRAGM BUILDINGS FIGURE b MAIN WIND FORCE LOADING DIAGRAM FLORIDA BUILDING CODE BUILDING 16.13

11 FIGURE (2) For SI: 1 degree = rad. FIGURE (c) COMPONENT AND CLADDING LOADING DIAGRAMS FLORIDA BUILDING CODE BUILDING

12 based on straight bond or broken bond and the tile profile. GC p = roof coefficient for each applicable zone determined from ASCE 7. Roof coefficient shall not be adjusted for internal pressure. Concrete and clay roof tiles complying with the following limitations shall be designed to withstand the wind loads prescribed in this section. 1. The roof tiles shall be either loose laid on battens or mechanically fastened or mortar set or adhesive set. 2. The roof tiles shall be installed on solid sheathing which has been designed as components and cladding in accordance with An underlayment shall be installed in accordance with The tile shall be single lapped interlocking with a minimum head lap of not less than 2 inches (51 mm). 5. The length of the tile shall be between 1.0 and 1.75 ft (305 and 533 mm). 6. The exposed width of the tile shall be between 0.67 and 1.25 ft (203 and 381 mm). 7. Maximum thickness of the tail of the roof tile shall not exceed 1.3 inches (33 mm). 8. Roof tiles using mortar set or adhesive set systems shall have at least 2/3 of the tile s area free of mortar or adhesive contact. FLORIDA BUILDING CODE BUILDING 16.15

FLORIDA BUILDING CODE BUILDING

FLORIDA BUILDING CODE BUILDING PREFACE History The State of Florida first mandated statewide building codes during the 1970s at the beginning of the modern construction boom. The first law required all municipalities and counties to

More information

Calculation of Wind Loads on Structures according to ASCE 7-10

Calculation of Wind Loads on Structures according to ASCE 7-10 Calculation of Wind Loads on Structures according to ASCE 7-10 Permitted Procedures The design wind loads for buildings and other structures, including the Main Wind-Force Resisting System (MWFRS) and

More information

STRUCTURAL DESIGN CRITERIA

STRUCTURAL DESIGN CRITERIA CHAPTER 3 STRUCTURAL DESIGN CRITERIA SECTION 301 GENERAL 301.1 Scope. Loads and load combinations shall be determined in accordance with ASCE 7 unless otherwise noted. Structural elements of the storm

More information

STRUCTURAL DESIGN CRITERIA

STRUCTURAL DESIGN CRITERIA CHAPTER 3 STRUCTURAL DESIGN CRITERIA SECTION 301 GENERAL 301.1 Scope. Loads and load combinations shall be determined in accordance with ASCE 7 unless otherwise noted. Structural elements of the storm

More information

ESR-2015P* Reissued April 2014 This report is subject to renewal April 1, 2015.

ESR-2015P* Reissued April 2014 This report is subject to renewal April 1, 2015. ICC-ES Evaluation Report ESR-2015P* Reissued April 2014 This report is subject to renewal April 1, 2015. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

APPENDIX A - Seismic Terms, Tables and Figures:

APPENDIX A - Seismic Terms, Tables and Figures: APPENDIX A - Seismic Terms, Tables and Figures: Seismic Design Force, (F p ) G-force that the unit must be able to withstand. This number is calculated using the factors described below. a S 0.4 P DS z

More information

Hurricane wind shelter retrofit room standards for existing houses

Hurricane wind shelter retrofit room standards for existing houses Safety and Security Engineering 653 Hurricane wind shelter retrofit room standards for existing houses N. Yazdani 1, T. Townsend 1 & D. KilCollins 2 1 Florida A & M University- Florida State College of

More information

2012 Wood Frame Construction Manual: Wind Speed and Design Pressure Determination According to ASCE 7 10

2012 Wood Frame Construction Manual: Wind Speed and Design Pressure Determination According to ASCE 7 10 2012 Wood Frame Construction Manual: Wind Speed and Design Pressure Determination According to ASCE 7 10 Presented by: William L. Coulbourne, PE Copyright Materials This presentation is protected by US

More information

ASCE 7-10 Significant Changes to the Wind Load Provisions

ASCE 7-10 Significant Changes to the Wind Load Provisions ASCE 7-10 Significant Changes to the Wind Load Provisions William L. Coulbourne, P.E. SECB Applied Technology Council (ATC) bcoulbourne@atcouncil.org Acknowledgements Ron Cook, Univ. of Florida, Wind Load

More information

VP University WEBINAR Loads and Codes

VP University WEBINAR Loads and Codes VP University WEBINAR Loads and Codes Building Codes 2 Builder Responsibilities VPC Loading Screens Load & Code Data Supplied by the Builder Verify with Engineer of Record Pursue most accurate data Assures

More information

Impact of C&C loads due to ASCE/SEI Overview Revised 3/23/2017

Impact of C&C loads due to ASCE/SEI Overview Revised 3/23/2017 Impact of C&C loads due to ASCE/SEI 7-16 Overview Revised 3/23/2017 SBCA has been the voice of the structural building components industry since 1983, providing educational programs and technical information,

More information

ANSI/SPRI Wind Design Standard Practice for Roofing Assemblies

ANSI/SPRI Wind Design Standard Practice for Roofing Assemblies Approved September 3, 2008 ANSI/SPRI WD-1 ANSI/SPRI Wind Design Standard Practice for Roofing Assemblies TABLE OF CONTENTS Section Page 1.0 INTRODUCTION...........................................................

More information

DynoRaxx EVOLUTION PR Guide to Code Compliant Installation

DynoRaxx EVOLUTION PR Guide to Code Compliant Installation DynoRaxx EVOLUTION PR Guide to Code Compliant Installation Publication Number 100611 866.620.2410 dynoraxx.com Table of Contents I. Installer Responsibilities... 3 II. Simplified Procedure for Calculating

More information

ROOF FRAMING ANCHORAGE FORCES: MWFRS

ROOF FRAMING ANCHORAGE FORCES: MWFRS TECHNICAL NOTE On Cold-Formed Steel Construction 1201 15th Street, NW, Suite 320 W ashington, DC 20005 (202) 785-2022 $5.00 ROOF FRAMING ANCHORAGE FORCES: MWFRS or C&C Summary: This Technical Note defines

More information

Part III Building Planning and Construction

Part III Building Planning and Construction Part III Building Planning and Construction CHAPTER 3 BUILDING PLANNING SECTION R301 DESIGN CRITERIA R301.1 Application. Buildings and structures, and all parts thereof, shall be constructed to safely

More information

Scope. resistance expressed as a moment

Scope. resistance expressed as a moment ROOFING APPLICATION STANDARD (TAS) No. 102-95 TEST PROCEDURE FOR STATIC UPLIFT RESISTANCE OF MECHANICALLY ATTACHED, RIGID ROOF SYSTEMS [For Mechanically Attached, Rigid Roof Systems Accompanied by a Clip,

More information

PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED

PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED Ministry of Municipal Affairs PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED CHANGE NUMBER: SOURCE: B-04-01-11 Ontario-NBC CODE REFERENCE: Division B / 4.1.7. DESCRIPTION OF THE PROPOSED

More information

ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95

ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95 ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95 TEST PROCEDURE FOR STATIC UPLIFT RESISTANCE OF MECHANICALLY ATTACHED, CLIPPED, RIGID, ROOF SYSTEMS (For Methods of Mechanical Attachment Excluding Clips,

More information

ANSI/SPRI RP Wind Design Standard For Vegetative Roofing Systems

ANSI/SPRI RP Wind Design Standard For Vegetative Roofing Systems For Vegetative Table of Contents 1.0 Introduction...2 2.0 Definitions...2 3.0 General Design Considerations and System Requirements...6 4.0 Design Options...8 5.0 Design Provisions...10 6.0 Determination

More information

SUMMARY OF RESIDENTIAL CODE GENERAL PROVISIONS 2004 Florida Building Code

SUMMARY OF RESIDENTIAL CODE GENERAL PROVISIONS 2004 Florida Building Code SUMMARY OF RESIDENTIAL CODE GENERAL PROVISIONS 2004 Florida Building Code The base document for the Florida Building Code, Residential, is the 2003 International Residential Code. Many Florida-specific

More information

ASCE 7 10 Wind Code Understanding

ASCE 7 10 Wind Code Understanding RE: ASCE-7-10 / 60 + Building Coastal Medical Center 123 Carolina Dr Coastal, NC To Whom It May Concern: ASCE 7 10 Wind Code Understanding There is no test in the roofing industry that blows 110 mph winds

More information

CALCULATING WIND LOADS ON LOW-RISE STRUCTURES PER 2015 WFCM ENGINEERING PROVISIONS (STD342-1)

CALCULATING WIND LOADS ON LOW-RISE STRUCTURES PER 2015 WFCM ENGINEERING PROVISIONS (STD342-1) CALCULATING WIND LOADS ON LOW-RISE STRUCTURES PER 015 WFCM ENGINEERING PROVISIONS (STD34-1) John Buddy Showalter, P.E. Vice President, Technology Transfer American Wood Council Description The Wood Frame

More information

LATERAL LOADS ON BRICK VENEER RESIDENTIAL STRUCTURES

LATERAL LOADS ON BRICK VENEER RESIDENTIAL STRUCTURES LATERAL LOADS ON BRICK VENEER RESIDENTIAL STRUCTURES W. Mark McGinley 1, PhD, PE and Eric N. Johnson 2, PE ABSTRACT In North American residential construction, brick veneer is typically used as a cladding

More information

Web: Joe Belcher, CBO, President (352) (813) Fax

Web:   Joe Belcher, CBO, President (352) (813) Fax Web: WWW.BRBCODEEDUCATORS.COM Joe Belcher, CBO, President Joe@JDBCodeServices.com (352) 450-2631 (813) 925-4152 Fax 1 2010 Florida Building Code, Building With Supplements/Structural Summary Contact Hours:

More information

There have been many instances of aircraft hangars roof systems

There have been many instances of aircraft hangars roof systems Photo 1: A substantial amount of roof deck material blew off these hangars. At one hangar, many trusses also were blown away. Two nearby fighter aircraft appeared to be damaged, as well. There have been

More information

PRODUCT EVALUATION Effective July 1, 2014 RC-28

PRODUCT EVALUATION Effective July 1, 2014 RC-28 TEXAS DEPARTMENT OF INSURANCE Engineering Services Program / M03-3A 333 Guadalupe Street P.O. Box 149104 Austin, Texas 78714-9104 Phone No. (512) 322-2212 Fax No. (512) 463-6693 PRODUCT EVALUATION Effective

More information

WIND LOADS ON BUILDINGS MWFRS (ENVELOPE PROCEDURE)

WIND LOADS ON BUILDINGS MWFRS (ENVELOPE PROCEDURE) Chapter C28 WIND LOADS ON BUILDINGS MWFRS (ENVELOPE PROCEDURE) The Envelope Procedure is the former low-rise buildings provision in Method 2 of ASCE 7-05 for MWFRS. The simplified method in this chapter

More information

Wind Load Report - Check for uplift

Wind Load Report - Check for uplift Wind Load Report - Check for uplift 1. Site & Building Data Roof Type: Gable Wind Speed (ult): 115 mph Exposure Category: C Enclosure Class: Enclosed Building Width (W): 43 ft. Building Length (L): 60

More information

5 Load Determination and Structural Design Criteria

5 Load Determination and Structural Design Criteria 5 Load Determination and Structural Design Criteria This chapter presents a summary of previous research and testing and outlines the recommended methods and criteria for use in the structural design of

More information

Wind Load Report - Naples Residence

Wind Load Report - Naples Residence Wind Load Report - Naples Residence 1. Site & Building Data Roof Type: Gable Wind Speed (ult): 115 mph Exposure Category: C Enclosure Class: Enclosed Building Width (W): 20 ft. Building Length (L): 23

More information

TESTING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR STATIC UPLIFT RESISTANCE OF MORTAR OR ADHESIVE SET TILE SYSTEMS

TESTING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR STATIC UPLIFT RESISTANCE OF MORTAR OR ADHESIVE SET TILE SYSTEMS TESTING APPLICATION STANDARD (TAS) No. 101-95 TEST PROCEDURE FOR STATIC UPLIFT RESISTANCE OF MORTAR OR ADHESIVE SET TILE SYSTEMS 1. Scope 2. Referenced Documents 1.1 This Protocol covers the determination

More information

SBCCI PUBLIC SAFETY TESTING AND EVALUATION SERVICES INC.

SBCCI PUBLIC SAFETY TESTING AND EVALUATION SERVICES INC. SBCCI PUBLIC SAFETY TESTING AND EVALUATION SERVICES INC. 900 Montclair Road, Suite A; Birmingham, Alabama 35213-1206 www.sbccies.org a Participating Member of the NES, Inc. Evaluation Reports are the opinion

More information

REVISION RECORD FOR THE STATE OF CALIFORNIA ERRATA

REVISION RECORD FOR THE STATE OF CALIFORNIA ERRATA REVISION RECORD FOR THE STATE OF CALIFORNIA ERRATA September 1, 2017 2016 Title 24, Part 2, Vol. 2, California Building Code General Information: 1. The date of these errata is for identification purposes

More information

FLORIDA BUILDING CODE

FLORIDA BUILDING CODE ASCE 7 10 WIND ZONE MAP RISK CATEGORY II 6 DESIGNATED AREAS WHERE THE BASIC WIND SPEED IS 140 MPH OR GREATER 130 MPH AND WITHIN 1 MILE OF COAST NOTE: THIS MAP IS ACCURATE TO THE COUNTY, IT IS NOT TO BE

More information

HURRICANE AND SEVERE WEATHER LOUVERS. Florida Product Approved and Miami-Dade Qualified Louvers

HURRICANE AND SEVERE WEATHER LOUVERS. Florida Product Approved and Miami-Dade Qualified Louvers HURRICANE AND SEVERE WEATHER LOUVERS Florida Product Approved and Miami-Dade Qualified Louvers MODELS FLORIDA PRODUCT APPROVED 4DHPF 4DHPF Florida Product Approved High Performance Drainable Blade Louvers

More information

INTERNATIONAL CODE COUNCIL (ICC) Code Technology Committee (CTC) INTERIM REPORT NO. 1 OF THE CTC AREA OF STUDY REVIEW OF NIST WTC RECOMMENDATIONS

INTERNATIONAL CODE COUNCIL (ICC) Code Technology Committee (CTC) INTERIM REPORT NO. 1 OF THE CTC AREA OF STUDY REVIEW OF NIST WTC RECOMMENDATIONS INTERNATIONAL CODE COUNCIL (ICC) Code Technology Committee (CTC) INTERIM REPORT NO. 1 OF THE CTC AREA OF STUDY REVIEW OF NIST WTC RECOMMENDATIONS Wyndham O Hare Rosemont, IL The CTC held a public hearing

More information

Wind Design Standard For Ballasted Single-ply Roofing Systems

Wind Design Standard For Ballasted Single-ply Roofing Systems Wind Design Standard For Ballasted Single-ply Roofing Systems 1.0 INTRODUCTION This standard provides a method of designing wind uplift resistance of ballasted singleply roofing systems. It is intended

More information

Christopher North Builders INC

Christopher North Builders INC Christopher North Builders INC Naples, Florida 239-825-9155 chrisnorthnaples@gmail.com Inspection Date: Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation

More information

JC Code & Construction Consultants, Inc. Advanced 2010 FBC Update Ch. 1 to 16

JC Code & Construction Consultants, Inc. Advanced 2010 FBC Update Ch. 1 to 16 JC Code & Construction Consultants, Inc. Advanced 2010 FBC Update Ch. 1 to 16 Welcome! This course is designed to provide an overview of the most significant changes to the 2010 edition of the Florida

More information

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Inspection Date: Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Owner Information Owner Name: Contact Person: Address:

More information

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Inspection Date: Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Owner Information Owner Name: Contact Person: Address:

More information

Addition. Wind Loads on Rooftop Solar Panels , At a Glance Standard. Wind Loads on Rooftop Solar Panels

Addition. Wind Loads on Rooftop Solar Panels , At a Glance Standard. Wind Loads on Rooftop Solar Panels Wind Loads on Rooftop Solar Panels 29.4.3, 29.4.4 At a Glance New provisions for determining wind loads on solar panels on buildings have been added to ASCE 7-16. One method applies specifically to low-sloped

More information

Part III Building Planning and Construction

Part III Building Planning and Construction Part III Building Planning and Construction CHAPTER 3 BUILDING PLANNING SECTION R301 DESIGN CRITERIA R301.1 Application. Buildings and structures, and all parts thereof, shall be constructed to safely

More information

Christopher North Builders, INC.

Christopher North Builders, INC. Christopher North Builders, INC. 239-825-9155 Naples, Florida 34108 chrisnorthnaples@gmail.com Inspection Date: Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation

More information

Executive Summary Building Description: Introduction... 13

Executive Summary Building Description: Introduction... 13 Table of Contents Executive Summary... 2 Building Description:... 2 Report Summary:... 2 Introduction... 3 Building Description:... 3 Current Framing Layout... 4 Report Topics:... 4 Loads and Load Cases...

More information

Stone and Masonry Veneer

Stone and Masonry Veneer Stone and Masonry Veneer R703.7 Stone and masonry veneer, general. Stone and masonry veneer shall be installed in accordance with this chapter, Table R703.4 and Figure R703.7. These veneers installed over

More information

Go Green Thermal Imaging, LLC P.O. Box 1523 Hobe Sound, FL Phone: GGTI (4484)

Go Green Thermal Imaging, LLC P.O. Box 1523 Hobe Sound, FL Phone: GGTI (4484) Go Green Thermal Imaging, LLC P.O. Box 1523 Hobe Sound, FL 33475 Phone: 888-984-GGTI (4484) E-mail:CPlaia@GGTISolutions.com Wind Mitigation Walt Leary 637 NE 12th Ter, Unit 7 Boynton Beach, FL 33435 September

More information

DATE:6/18/2013 INSPECTOR: ELEVATION

DATE:6/18/2013 INSPECTOR: ELEVATION DATE:6/18/2013 INSPECTOR: C ELEVATION DATE:6/18/2013 ROOF DECK ATTACHMENT ROOF TO WALL OPENING PROTECTION NA DOCUMENTS/ PERMITS, TITUSVILLE 32780 Permit #12-768 Applied: 5.14.12 Issued: 5.14.12 Final:

More information

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Inspection Date: Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Jul 16, 2012 Owner Information Owner Name: John Miller

More information

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Inspection Date: 05/24/2017 Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Owner Information Owner Name: Banana Bay

More information

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy Inspection Date: Owner Information Owner Name: Address: Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy Contact Person: Home Phone: City: Zip: Work

More information

Association of Caribbean States 2003

Association of Caribbean States 2003 MODEL BUILDING CODE FOR WIND LOADS Final Version, May 2003 Association of Caribbean States 2003 5-7 Sweet Briar Road, St. Clair, P.O. Box 660 Port of Spain, Trinidad and Tobago, West Indies Tel: (868)

More information

Page 1 of 21

Page 1 of 21 www.garyklinka.com Page 1 of 21 UDC Wall Bracing Provisions quiz Instructions 1. Print these pages. Fee $30 2. Answer the Simple questions that follow mini sections of the code language. 3. Circle the

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BARTILE ROOFS, INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BARTILE ROOFS, INC. EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2778 Reissued 07/2018 This report is subject to renewal 07/2019. DIVISION: 07 00

More information

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Inspection Date: 12/07/2018 Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Owner Information Owner Name: The Oaks

More information

2.0 SELECTING APPROPRIATE SECUREMENT MATERIALS

2.0 SELECTING APPROPRIATE SECUREMENT MATERIALS HYDROGUARD Installation Guide 1.0 GENERAL DESIGN CONSIDERATIONS The design professional should consider the following factors when designing a Protected Membrane Roof utilizing Hydroguard. Roof Structure

More information

NCMA TEK RESIDENTIAL DETAILS FOR HIGH WIND AREAS. TEK 5-11 Details (2003)

NCMA TEK RESIDENTIAL DETAILS FOR HIGH WIND AREAS. TEK 5-11 Details (2003) NCM TEK National Concrete Masonry ssociation an information series from the national authority on concrete masonry technology RESIDENTIL DETILS FOR HIGH WIND RES TEK 5-11 Details (2003) Keywords: architectural

More information

POST AND FRAME STRUCTURES (Pole Barns)

POST AND FRAME STRUCTURES (Pole Barns) POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:

More information

Part III Building Planning and Construction

Part III Building Planning and Construction Part III Building Planning and Construction CHAPTER 3 BUILDING PLANNING SECTION R301 DESIGN CRITERIA R301.1 Application. Buildings and structures, and all parts thereof, shall be constructed to safely

More information

Go Green Thermal Imaging, LLC P.O. Box 1523 Hobe Sound, FL Phone: GGTI (4484)

Go Green Thermal Imaging, LLC P.O. Box 1523 Hobe Sound, FL Phone: GGTI (4484) Go Green Thermal Imaging, LLC P.O. Box 1523 Hobe Sound, FL 33475 Phone: 888-984-GGTI (4484) E-mail:CPlaia@GGTISolutions.com Wind Mitigation Richard & Andrea Freedman 182 Eagle Dr. Jupiter, FL 33477 March

More information

Pulaski County, Virginia Practical Wall Bracing

Pulaski County, Virginia Practical Wall Bracing Pulaski County, Virginia Practical Wall Bracing Based on the 2012 Virginia Residential Code The information herein provides guidelines for complying with the most common Practical Wall Bracing provisions

More information

REINFORCING TABLES INSTALLATION MANUAL

REINFORCING TABLES INSTALLATION MANUAL REINFORCING TABLES 201 REINFORCING TABLES Design Limitations Introduction The structural wall reinforcing and lintel design tables contained within the Appendix of NUDURA s Installation Manual have been

More information

research report Cold-Formed Steel Gable End Wall Design Using the Prescriptive Method for One and Two Family Dwellings RESEARCH REPORT RP05-2

research report Cold-Formed Steel Gable End Wall Design Using the Prescriptive Method for One and Two Family Dwellings RESEARCH REPORT RP05-2 research report Cold-Formed Steel Gable End Wall Design Using the Prescriptive Method for One and Two Family Dwellings RESEARCH REPORT RP05-005 REVISION 006 American Iron and Steel Institute Cold-Formed

More information

ICC/NSSA STANDARD FOR THE DESIGN AND CONSTRUCTION OF STORM SHELTERS

ICC/NSSA STANDARD FOR THE DESIGN AND CONSTRUCTION OF STORM SHELTERS ICC/NSSA STANDARD FOR THE DESIGN AND CONSTRUCTION OF STORM SHELTERS ICC 500-2013 edition Public Comment Draft #2 The ICC Consensus Committee on Storm Shelters has held 1 public meetings to develop the

More information

STRUCTURAL NOTES MISCELLANEOUS COLD-FORM STEEL FRAMING MASONRY SITE WORK CAST IN PLACE CONCRETE

STRUCTURAL NOTES MISCELLANEOUS COLD-FORM STEEL FRAMING MASONRY SITE WORK CAST IN PLACE CONCRETE STRUCTURAL NOTES MISCELLANEOUS COLD-FORM STEEL FRAMING MASONRY AA 0009 707 US Hwy. 9 Palm Harbor, FL 68 Phone 77. 78. 7 Fax 77. 78. 66 SITE WORK CAST IN PLACE CONCRETE OPEN WEB STEEL JOISTS AND JOIST GIRDERS

More information

Technical Assignment 1 10/8/03

Technical Assignment 1 10/8/03 Executive Summary Technical Assignment 1 10/8/03 The is 55 story high-rise condominium being built off the northern Miami coast. The structural design presented in this building is a direct result of its

More information

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with insurance policy Uniform Mitigation Verification Inspection Form Maintain a copy of this form with insurance policy Inspection Date: 08/12/2011 Owner Information Owner Name: Steve Owner Contact Person: Joe Contact Address:

More information

INSTALLATION INSTRUCTIONS FOR THE BOULDERS LISTED BELOW:

INSTALLATION INSTRUCTIONS FOR THE BOULDERS LISTED BELOW: INSTALLATION INSTRUCTIONS FOR THE BOULDERS LISTED BELOW: SND - SM SND - MD SND - LG GRN - SM GRN - MD GRN - LG WARNING: The surfacing under and around playground equipment is one of the most important

More information

UDC Wall Bracing Provisions Emergency Rule effective date 4/1/2014. A How To guide for use of the new provisions

UDC Wall Bracing Provisions Emergency Rule effective date 4/1/2014. A How To guide for use of the new provisions UDC Wall Bracing Provisions Emergency Rule effective date 4/1/2014 A How To guide for use of the new provisions Summary: Forget what you knew about the previous wall bracing provisions this method is a

More information

2015 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

2015 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata) SECOND PRINTING (Updated October 22, 2015) SECTION 202 [RB] GRADE FLOOR OPENING. A window or other opening located such that the sill height of the opening is not more than 44 inches (1118 mm) above or

More information

RESIDENTIAL RE-ROOFING PERMIT APPLICATION

RESIDENTIAL RE-ROOFING PERMIT APPLICATION RESIDENTIAL RE-ROOFING PERMIT APPLICATION Effective date: October 1, 2007. Note: These requirements apply to residential structures built prior to implementation of the FBC on March 1, 2002. I. LEGAL DESCRIPTION:

More information

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS WOOD CHAPTER 3 301 SCOPE This chapter prescribes construction requirements for buildings where all exterior walls above the foundation are wood framed

More information

A REPORT ON THE EFFECTS OF WIND SPEED ON TIMBER CONSTRUCTION JOSHUA HUENEFELD. B.S., Kansas State University, 2012 A REPORT

A REPORT ON THE EFFECTS OF WIND SPEED ON TIMBER CONSTRUCTION JOSHUA HUENEFELD. B.S., Kansas State University, 2012 A REPORT A REPORT ON THE EFFECTS OF WIND SPEED ON TIMBER CONSTRUCTION by JOSHUA HUENEFELD B.S., Kansas State University, 2012 A REPORT submitted in partial fulfillment of the requirements for the degree MASTER

More information

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy Inspection Date: Owner Information Owner Name: Address: Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy Contact Person: Home Phone: City: Zip: Work

More information

COMMERCIAL WINDSTORM MITIGATION INSPECTION REPORT Prepared for: Boca Vista Condominium Association, Inc th Avenue Madeira Beach, FL 33708

COMMERCIAL WINDSTORM MITIGATION INSPECTION REPORT Prepared for: Boca Vista Condominium Association, Inc th Avenue Madeira Beach, FL 33708 Insurance Appraisals Reserve Studies Wind Mitigation COMMERCIAL WINDSTORM MITIGATION INSPECTION REPORT Prepared for: Boca Vista Condominium Association, Inc. 401 150th Avenue Madeira Beach, FL 33708 As

More information

Structural Criteria for Residential Rooftop Solar Energy Installations

Structural Criteria for Residential Rooftop Solar Energy Installations Structural Criteria for Residential Rooftop Solar Energy Installations This document applies to flush mounted solar arrays installed on the roofs of wood framed one and two family dwellings. Flush mounted

More information

1. Asphalt / Fiberglass Shingle / / 2. Concrete / Clay Tile 05_/_01 /_ Metal / / 4. Built Up / / 5. Membrane / / 6.

1. Asphalt / Fiberglass Shingle / / 2. Concrete / Clay Tile 05_/_01 /_ Metal / / 4. Built Up / / 5. Membrane / / 6. Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation with the insurance policy Inspection Date: 14-Aug-14 Owner Information Owner Name: Contact Person: Brett

More information

Wood Shear Wall Design Examples For Wind

Wood Shear Wall Design Examples For Wind Wood Design Examples For Wind EARN 0.1 ICC Continuing Education Unit (CEU) and/or AIA/CES HSW 1 Learning Unit (LU) DES413-A Wood Design Examples for Wind Description: In this article, a wood frame shear

More information

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Inspection Date: 04/01/2015 Owner Information Owner Name: JACK AND

More information

INGHOUSE Page 1 of 48

INGHOUSE Page 1 of 48 INGHOUSE Page 1 of 48 Lars Jensen P.E., S.E. Web: www.inghouse.net EMAIL: jensen@inghouse.net INGHOUSE Page 2 of 48 OBJECTIVES: DESIGN OPTIONS; WHY ENGINEERED DESIGN DEVELOP AN UNDERSTANDING OF MAGNITUDE

More information

Florida Structural Engineers

Florida Structural Engineers Florida Structural Engineers South Florida Chapter January 8, 2008 Miami Lakes, Florida Aluminum Association of Florida, Inc. Joe Belcher ~ David Miller AAF Code Involvement: Historical Perspective 1998:

More information

APPENDIX. WOOD JOIST/RAFTER MAXIMUM SPANS ( for 16 o.c. spacing) WITH SINGLE ROW OF PV PANELS AT MIDSPAN (ft.) AND PANEL SUPPORT AT 32 o.c.

APPENDIX. WOOD JOIST/RAFTER MAXIMUM SPANS ( for 16 o.c. spacing) WITH SINGLE ROW OF PV PANELS AT MIDSPAN (ft.) AND PANEL SUPPORT AT 32 o.c. 1 Span Tables The following Wood Joist/Rafter Maximum Span Tables can be used to determine the adequacy of an existing wood framed roof structure to support the additional dead load created by PV panel

More information

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.) DIVISION 94 VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.) SEC. 91.9401. PURPOSE. (Amended by Ord. No. 172,592, Eff. 6/28/99,

More information

2.0 SELECTING APPROPRIATE SECUREMENT MATERIALS

2.0 SELECTING APPROPRIATE SECUREMENT MATERIALS HYDROGUARD Installation Guide 1.0 GENERAL DESIGN CONSIDERATIONS The design professional should consider the following factors when designing a Protected Membrane Roof utilizing Hydroguard. Roof Structure

More information

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued) 2000 IRC 1997 NEHRP Section Provision Section Provision Comments CHAPTER 3 BUILDING PLANNING R301 DESIGN CRITERIA R301.2.2 Seismic Provisions R301.2.2.1 Determination of Seismic Design Category R301.2.2.1.1

More information

Showing Only Sections Changed 6 th Edition FBC (2017) from 5 th Edition FBC (2015) [changes shown with underline and strike-through]

Showing Only Sections Changed 6 th Edition FBC (2017) from 5 th Edition FBC (2015) [changes shown with underline and strike-through] Showing Only Sections Changed 6 th Edition FBC (2017) from 5 th Edition FBC (2015) [changes shown with underline and strike-through] This publication reproduces excerpts from the Florida Building Code,

More information

R CODE CHANGE PROPOSAL FORM (See instructions on page 2)

R CODE CHANGE PROPOSAL FORM (See instructions on page 2) CODE CHANGE PROPOSAL FORM (See instructions on page 2) Code: IRC 12/13 Sections 301.2.2.2.1 Proponent: Charles S. Bajnai, Chesterfield County, VA, ICC Building Code Action Committee 1. Delete as shown

More information

Joseph L. Oliveri, AIA

Joseph L. Oliveri, AIA c < < < < < < Joseph L. Oliveri, AIA Joseph L. Oliveri, AIA PARKING BY DISABLED PERMIT ONLY $ xxx FINE F.S. 318.14 Joseph L. Oliveri, AIA Joseph L. Oliveri, AIA Joseph L. Oliveri, AIA Joseph L. Oliveri,

More information

Structural Criteria for Residential Rooftop Solar Energy Installations

Structural Criteria for Residential Rooftop Solar Energy Installations PV TOOLKIT PV TOOLKIT DOCUMENT #5 Structural Criteria for Residential Rooftop Solar Energy Installations Use of this document This toolkit document includes a one-page list of structural criteria for over-the-counter

More information

Structural Criteria for Residential Rooftop Solar Energy Installations

Structural Criteria for Residential Rooftop Solar Energy Installations SWH TOOLKIT DOCUMENT #4 Structural Criteria for Residential Rooftop Solar Energy Installations Use of this document This toolkit document includes a one-page list of structural criteria for over-the-counter

More information

2007 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (RAS)

2007 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (RAS) ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES 1.. 3. Scope

More information

This permit is issued under OAR Permits expire if work is not started within 180 days of issuance or if work is suspended for 180 days.

This permit is issued under OAR Permits expire if work is not started within 180 days of issuance or if work is suspended for 180 days. Prescriptive Solar Photovoltaic Installation Permit Application Marion County Public Works 5155 Silverton Rd NE, Salem, Oregon 97305 Phone: (503) 588-5147 Fax: (503) 588-7948 Email: Building@co.marion.or.us

More information

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy Inspection Date: Owner Information Owner Name: Address: Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy Contact Person: City: Jupiter Zip: 33458 Work

More information

Structural Criteria for Residential Rooftop Solar Energy Installations

Structural Criteria for Residential Rooftop Solar Energy Installations SWH TOOLKIT DOCUMENT #4 Structural Criteria for Residential Rooftop Solar Energy Installations Use of this document This toolkit document includes a one-page list of structural criteria for over-the-counter

More information

ANSI/SPRI RP Wind Design Standard For Ballasted Single-ply Roofing Systems

ANSI/SPRI RP Wind Design Standard For Ballasted Single-ply Roofing Systems ANSI/SPRI RP-4 2013 For Ballasted Single-ply Table of Contents 1.0 Introduction...2 2.0 Definitions....2 3.0 General Design Considerations and System Requirements...5 4.0 Design Options...8 5.0 Design

More information

Page Roof Covering Type: Permit Application Date FBC or MDC Product Approval #

Page Roof Covering Type: Permit Application Date FBC or MDC Product Approval # Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Inspection Date: 1/5/2013 Owner Information Owner Name: Sinha Contact

More information

OVERALL STRUCTURAL SYSTEM

OVERALL STRUCTURAL SYSTEM EXECUTIVE SUMMARY The at the Pittsburgh International Airport, PA, is a 275,000 square foot multi-use building located directly adjacent to the airport s landside terminal. The building consists of an

More information

2001 COMPANY Co., ASCE 7 98 Wind Uplift Evaluation Form (Ask for Form - ASCE7dpi.doc)

2001 COMPANY Co., ASCE 7 98 Wind Uplift Evaluation Form (Ask for Form - ASCE7dpi.doc) 2001 COMPANY 2001 Co., ASCE 7 98 Wind Uplift Evaluation Form (Ask for Form - ASCE7dpi.doc) To determine a roof s wind uplift PSF (pounds per square foot) Pressure requirement for building code compliance.

More information

Structural Criteria for Residential Rooftop Solar Energy Installations

Structural Criteria for Residential Rooftop Solar Energy Installations SWH TOOLKIT DOCUMENT #4 Your City logo here Structural Criteria for Residential Rooftop Solar Energy Installations Use of this document This toolkit document includes a one-page list of structural criteria

More information