1 VILLAGE OF PALATINE DIVISION OF BUILDING PERMITS AND INSPECTIONS 200 East Wood Street Palatine, IL Telephone (847) Fax (847) EXPRESS PERMIT INFORMATION ASPHALT DRIVEWAY CONSTRUCTION REQUIREMENTS: Asphalt driveways shall be paved with at least 1-1/2 inches of plant mixed asphalt. Asphalt driveway aprons in the Village right of way (parkway) shall be paved with at least 1-1/2 inches of plant mixed asphalt. All asphalt shall be placed over at least 4 inches of graded and compacted gravel base material. No pea gravel allowed as a base material for driveways. CONCRETE DRIVEWAY CONSTRUCTION REQUIREMENTS: Concrete driveways shall be constructed with at least 5 inches of air entrained concrete fc=3500 psi, with a cement content per ACI318. Concrete driveway aprons in the Village right of way (parkway) shall be constructed with at least 5 inches of air entrained fc=3500 psi, with a cement content per ACI318. All concrete shall be placed over at least 4 inches of graded and compacted gravel base material. No pea gravel allowed as a base material for driveways. Wire mesh is not allowed in the parkway (apron) or public walk area. GARAGE FLOOR CONSTRUCTION REQUIREMENTS: Install thickened concrete edge at overhead door 14 inches down and 20 inches wide. This 14 inch measurement includes the 3 1/2 for the concrete floor replacement. At lease 4 inches of graded compacted gravel base material. Install (2) #5 5/8 inch diameter rebar approximately in bottom of thickened edge at overhead door, approximately 3 inches from bottom along full length. Install vapor barrier under attached garage slabs. Dowel beam into existing sides. PAVER DRIVEWAY CONSTRUCTION REQUIREMENTS: Construct brick pavers with a min. 4 inches compacted Grade C.A. 6 stone base and 1-1½ inches sand or as specified by the manufacturer. Edge restraints are to be spiked securely through the compacted base material and the bricks seated into the bedding sand by compaction. Brick pavers are not allowed within the public sidewalk area. DRIVEWAY ZONING REQUIREMENTS: Measurements shall be noted on the submitted Site Plan (see diagrams at right and refer to notes below for example) A Width at lot line, for a minimum distance of 5 feet. Maximum of 25 ft is permitted. B Width at widest point. Maximum 30 ft for a two-car garage or less Maximum 35 ft for a three-car garage or greater Minimum width: 9 ft C Side/Rear yard setback. 2 ft from interior side or interior rear lot line, except when a driveway is shared between 2 adjacent properties. D Length of drive shall be noted on the site plan

2 DECK CONSTRUCTION REQUIREMENTS: Decks may not cover basement windows, electric or gas meters, or vents. Identify their location on the drawing if in the general vicinity of the deck. All decks that are 30 or higher, require a continuous railing, 36" high. Baluster spacing shall be such that a 4" sphere cannot pass through any opening. All vegetation shall be removed from beneath the deck, and the ground covered with a minimum of four mil polyethylene covered with gravel. Joist hangers or ledger boards are required and where the deck is supported by attachment to an exterior wall, they shall be positively anchored to the primary structure and designed for both vertical and lateral loads. A special use permit is necessary if a proposed deck is in a floodplain and no portion of a deck may be in an easement. Decks shall be installed on a frost protected foundation meeting the approval of the Director of Community Services. See attached check sheet for additional requirements. DECK ZONING REQUIREMENTS: A deck less than sixteen (16) inches above grade shall be situated a minimum distance of two (2) feet from all side and rear lot lines. Decks in a front or corner side yard shall be situated a minimum distance of five (5) feet from the front and corner side lot lines. A deck sixteen inches or more above grade located adjacent to the residence is considered part of the principal structure and must meet the house setback and lot coverage requirements for the zoning district in which it is located. Decks shall not be located in easements. FENCE CONSTRUCTION REQUIREMENTS: "Finished side of fence shall face out. Fences shall be constructed in a manner providing sufficient support and stability to resist wind loads and to maintain its form. Chain link fences shall be constructed of at least eleven and a half (11.5) gauge woven wire - open ends of a wire fence shall be along the ground. FENCE ZONING REQUIREMENTS: General Fencing o Height: Fencing shall not exceed six (6) feet in height. o Type: No barbed wire or electrically charged fences are permitted. o Location and Setbacks Interior side and rear yards Fences are permitted in the rear and interior side yards. Front yards Fences must meet the front yard setback requirements in the zoning district. Side yard abutting a street Fences located in a side yard abutting a public street shall be setback a minimum of 5 feet from the lot line and shall not abut a front yard of an adjacent property. Rear yard abutting a street Fences located in a rear yard abutting a public street shall be setback a minimum of 5 feet from the lot line. Fences located in a rear yard abutting a public street shall include a gate to allow access to the rear street frontage. o Landscape material: shall be installed within the area between a fence and any lot line abutting a street. The landscape material shall include a combination of trees and shrubs with a minimum installed height of 36 inches. Decorative Fencing: (front yard, only) o Height: Fencing shall not exceed three (3) feet in height. o Length: Up to twenty (20) linear feet. o Type: No barbed wire or electrically charged fences are permitted. o Location and Setbacks: Permitted in front yards and corner side yards. Replacement of Existing Fence o Any existing fence, as of April 18, 2005, may be replaced in its current location without having to comply with the applicable setback requirements. Prior to obtaining a building permit the property owner shall provide proof that the fence existed in its current location prior to April 18, 2005.

3 ELECTRIC SERVICE REVISION CONSTRUCTION REQUIREMENTS: Grounding: Only copper wire shall be used for grounding of electric systems. When grounding for any system or combination of systems and equipment, the copper ground wire shall be run directly from the neutral in the service disconnect or distribution cabinet to the street side of the water service shut-off valve and shall have an approved jumper wire around the water meter with an approved metal I.D. tag denoting electrical ground. In addition, two1/2 inch diameter 8 foot long copper ground rod embedded 7 foot into the ground shall be provided with a copper ground wire run directly to the service disconnect. Service Entrance: The name and telephone number of the electrical contractor performing the work shall be displayed on the service panel. Service entrance conductor's shall be installed in rigid heavy-wall metal conduit with a cabinet containing not less than twenty (20) circuits. In all occupancies, those conductor's which supply all the current consumed by an individual occupancy, apartment, or dwelling unit shall be as follows: o Copper shall be used on the load side of the service. o All occupancies or dwelling units and apartments of any size shall have a one hundred (100) amp. minimum electric service rating. Service panels shall have a minimum of twenty (20) circuits. o The main disconnect switch shall be located in the approximate area where the service enters the building. o A disconnect shall be provided for all occupancies, apartments and dwelling units. o No more than 5 feet from service disconnect to dwelling panel board. Clearances: Conductors shall have a vertical clearance of not less than 8 feet from all points of roofs they pass, where the voltage between conductors does not exceed 300 volts and the roof has a slope of not less that 4/12 a reduction in clearance to 3 feet shall be permitted. Panelboard shall have a ¼ inch clearance to the wall. The above ground service drop shall be no closer that 3' 0'' from a window opening Maintain 30 inch width by 36 inch depth and 78 inch vertical clearance from face of exterior electrical meter FURNACE & A/C CONSTRUCTION REQUIREMENTS: Furnaces must be installed in accordance with manufacturers' installation instructions. Furnaces must be accessible for service, repair and replacement with not less than 30" of working space provided. Fuel shut-off valves must be provided for each unit. Vent connectors must be pitched at least 1/4 inch per foot, be securely supported, and joints fastened with sheet metal screws. Furnaces installed in confined spaces (provide sketch) must be provided with two openings. One opening must be within 12 inches of the top and one within 12 inches of the bottom space. Each opening must be sized 1 square inch per 1000 BTU input rating of all appliances installed within the space. A disconnect switch must be mounted within sight of the unit. Furnace must be properly fused with wire sized in accordance with the manufacturers' installation instructions All electric piping on exterior of building to be in rigid pipe except "seal-tight" will be allowed from electric disconnect to condensing unit. FURNACE & A/C ZONING REQUIREMENTS: A compressor or condensing unit for an air conditioning system must be located in either a rear or side yard unless such yards abut a street wherein said unit shall be located elsewhere. In any required side yard or required rear yard compressor or condenser units and heating pump systems for residential air conditioning systems and/or heating systems shall project not more than three (3) feet into the yard. LAWN SPRINKLER CONSTRUCTION REQUIREMENTS: Indicate polyethylene plastic pipe underground Type L copper shall be used for above ground water piping complete with lead free solder and installed by a licensed plumbing contractor. An R.P.Z valve shall be used. Indicate model # of R.P.Z. valve. All inside plumbing work, including the R.P.Z. valve shall be installed by a licensed plumber. R.P.Z. valve shall be certified prior to inspection. LAWN SPRINKLER LOCATION: A residential lawn sprinkler system may be installed anywhere inside the property lines of a given parcel. However, a residential lawn sprinkler system shall not be installed in an existing utility easement, without the approval of all utility companies. It should be noted that if permission is granted by the utility companies and a sprinkler system is installed over an existing easement, the property owner is responsible for replacing the lawn sprinkler system if damaged by the utility companies needing access. No irrigation lines or sprinkler heads are permitted in the right-of way without a signed hold harmless letter.

4 PAVER PATIO/SIDEWALK CONSTRUCTION REQUIREMENTS: Construct brick pavers with a min. 4 inches compacted Grade C.A. 6 stone base and 1-1½ inches sand or as specified by the manufacturer. Edge restraints are to be spiked securely through the compacted base material and the bricks seated into the bedding sand by compaction. Pitch sidewalk and patio away from building. Surface water drainage may not be directed onto adjacent properties. If a walk or patio includes steps or a stoop with more than 2 contiguous steps, a full permit application is required. Risers may not be more than 7 3/4 inches in height and treads not less than 11 inches in depth or 10 inches with nosing. PAVER PATIO/SIDEWALK ZONING REQUIREMENTS: A brick patio and/or sidewalk if less than 16 inches in height above grade should be situated a minimum of two (2) feet from all side and rear lot lines. A brick patio and/or sidewalk cannot be constructed on utility easements without the written permission of all utility companies. It should be noted that if permission is granted by the utility companies and a patio and/or sidewalk is constructed over an existing easement, the property owner is responsible for replacing the patio and/or sidewalk if damaged by the utility companies needing access. CONCRETE PATIO/SIDEWALK CONSTRUCTION REQUIREMENTS: Public concrete walks shall be constructed with at least 5 inches of air entrained concrete fc=3500 psi, with a cement content per ACI318. Private walks and patios shall be constructed with at least 4 inches of air entrained concrete fc=3500 psi, with a cement content per ACI318. All concrete shall be placed over at least 4 inches of graded and compacted gravel base material. No pea gravel allowed as a base material. Pitch sidewalk and patio away from building. Surface water drainage may not be directed onto adjacent properties. If a walk or patio includes steps or a stoop with more than 2 contiguous steps, a full permit application is required. Risers may not be more than 7 ¾ inches in height and treads not less than 11 inches in depth or 10 inches with a nosing. CONCRETE PATIO/SIDEWALK ZONING REQUIREMENTS: A concrete patio and/or sidewalk if less than 16 inches in height above grade should be situated a minimum of two (2) feet from all side and rear lot lines. A concrete patio and/or sidewalk cannot be constructed on utility easements without the written permission of all utility companies. It should be noted that if permission is granted by the utility companies and a patio and/or sidewalk is constructed over an existing easement, the property owner is responsible for replacing the patio and/or sidewalk if damaged by utility companies gaining access. SEWER REPAIR CONSTRUCTION REQUIREMENTS: Schedule 40 or S.D.R. #26 pipe is to be used. Install 6" PVC schedule 40 with "T" for outside clean out if none exists in sewer service rod-out station. Outside clean out is mandatory for outside sewer repair. The sewer repair or replacement section shall be installed in a gravel bed Install non-shear mission couplings on both ends Remove all old pipe out of ditch before backfill Rod out sewer to make sure it is working before backfill Remove debris from site caused by sewer repair - pop cans, rags, old pipe, etc. Any municipal property (parkway, street, curbs, sidewalk, etc) damaged during construction shall be restored and is subject to a one (1) year maintenance period. SHED CONSTRUCTION REQUIREMENTS: When storage sheds are built on other than concrete floors, the perimeter of the shed shall be constructed in a manner to discourage rodents from building nests under the structure. Regardless of the weight or size of the shed, it must be anchored to the ground by using hurricane anchors, posts, or a method approved by the Village of Palatine. If the shed is built on a wooden floor, the floor shall be constructed of pressure treated lumber or of a decay resistant species of lumber such as cedar. If a concrete floor is installed for the shed, the requirements shall be 4 inches of concrete over 4 inches of compacted fill.

5 SHED ZONING REQUIREMENTS: A maximum height of fifteen (15) feet as measured from the ground level to the mean height between the eave and ridge of a roof. A detached shed cannot be constructed on utility easements without the written permission of all utility companies. It should be noted that if permission is granted by the utility companies and a patio and/or sidewalk is constructed over an existing easement, the property owner is responsible for replacing the patio and/or sidewalk if damaged by utility companies gaining access. All sheds must be located in either the rear or side yards and be situated a minimum of ten (10) feet from the principal structure. In addition, sheds must be located a minimum of five (5) feet from all side and rear lot lines, not in the easements. If a rear lot line of a lot abuts the side lot line of a front yard of an adjacent lot, a shed must be setback a minimum of twenty (20) feet from the rear lot line. A shed cannot encroach upon the side yard of a corner lot which is adjacent to the street. In addition, a shed cannot encroach upon the corner side yard setback in a rear yard of a corner lot adjacent to the street. No portion of a shed shall overhang or be located in an easement. Ground floor area Rear yards: The ground floor area of all accessory structures located in a rear yard shall nor exceed the lesser of: i. Twenty (20) percent of the area of such rear yard or; ii. Seven hundred (700) square feet iii. Fifty percent (50) of the floor area of the principal structure Side yards: Maximum size is 150 square feet WATER HEATER CONSTRUCTION REQUIREMENTS: The water heater shall be installed in accordance with manufacturers specifications and the Illinois State Plumbing Code. A full port shut-off valve must be located on the cold water side. Water connections to the water heater must be made with dialectic unions if dissimilar metals are used. All soldering must be done with lead free solder. All copper pipe shall be type L rigid pipe, no flexible connectors. A relief valve and its discharge piping shall be of full size and extend to within 6 inches above the floor and discharge to a suitable drain. Install heat trap. Water heaters installed in a closet or other confined space must be provided with two ventilation openings. One opening must be within 12 inches of the top and one within 12 inches of the bottom space. Each opening must be sized 100 square inches. A new water heater replacement should be located in the same general area as the older water heater and if installed on a platform, shall again be installed on a platform of the same elevation as the original heater. A gas fired water heater in a garage must be raised 18 inches above the floor. If an electric water heater is installed, it must conform to the appropriate electrical code sections. Proper clearances as specified by the manufacturer must be provided between the water heater and combustible material. ABOVE GROUND POOL CONSTRUCTION REQUIREMENTS: Pools and associated elements shall be constructed in accordance with appendix G of the 2003 International Residential Code and the electrical requirements of the 2005 National Electrical Code. See attached reference sheets. Hose bibs used to fill the pool must be equipped with a vacuum breaker. ABOVE GROUND POOL ZONING REQUIREMENTS: An above ground swimming pool and any accessory equipment can be located in either a rear or side yard, however, above ground swimming pools are not permitted in front yards or side yards abutting a street. An above ground swimming pool and any accessory equipment must be situated a minimum of ten (10) feet from the principal structure and shall not be located closer than five (5) feet from any rear or side lot lines. Pools shall not be located on an easement. Ground floor area: o Rear yards: The ground floor area of all accessory structures located in a rear yard shall nor exceed the lesser of: Twenty (20) percent of the area of such rear yard or; Seven hundred (700) square feet Fifty percent (50) of the floor area of the principal structure

BUILDING & INSPECTIONS DIVISION 200 East Wood Street Palatine, IL Telephone (847)

BUILDING & INSPECTIONS DIVISION 200 East Wood Street Palatine, IL Telephone (847) 2018 EXPRESS PERMIT PRINT CLEARLY. ILLEGIBLE AND/OR INCOMPLETE S WILL BE RETURNED (this is a two sided application) Property/Owner Information check if applicant Project Address: Owner Name: Day Phone:

More information

1420 Miner Street Des Plaines, IL P: desplaines.org COMMERCIAL STRUCTURES (INCLUDING ALTERATIONS AND ADDITIONS)

1420 Miner Street Des Plaines, IL P: desplaines.org COMMERCIAL STRUCTURES (INCLUDING ALTERATIONS AND ADDITIONS) 1420 Miner Street Des Plaines, IL 60016 P: 847.391.5380 desplaines.org COMMERCIAL STRUCTURES (INCLUDING ALTERATIONS AND ADDITIONS) Five sets of stamped plans and specifications (six sets if food establishment),

More information

BUILDING & INSPECTIONS DIVISION 200 East Wood Street Palatine, IL Telephone (847)

BUILDING & INSPECTIONS DIVISION 200 East Wood Street Palatine, IL Telephone (847) 2018 EXPRESS PERMIT CONCRETE PATIO/ SIDEWALK/STOOP PRINT CLEARLY. ILLEGIBLE AND/OR INCOMPLETE S WILL BE RETURNED (this is a two sided application) Property/Owner Information check if applicant Project

More information

Village of Lombard Community Development Department/Building Division 255 E. Wilson Avenue Lombard, IL Tel: Fax:

Village of Lombard Community Development Department/Building Division 255 E. Wilson Avenue Lombard, IL Tel: Fax: Village of Lombard Community Development Department/Building Division 255 E. Wilson Avenue Lombard, IL 60148 Tel: 630-620-5750 Fax: 630-629-2374 Accessory Structures: Decks, Terraces, Gazebos, Porches,

More information

Building Department HOMEOWNERS MANUAL

Building Department HOMEOWNERS MANUAL Building Department HOMEOWNERS MANUAL VILLAGE OF MUNDELEIN BUILDING DEPARTMENT 440 East Hawley Street 847-949-3283 Mundelein, Illinois 60060 (fax) 847-949-4278 www.mundelein.org Office Hours: weekdays

More information

Residential Miscellaneous Permits

Residential Miscellaneous Permits Residential Miscellaneous Permits Planning and Development Services Department Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org

More information

ATTACHED/DETACHED GARAGE BUILDING PERMIT APPLICATION

ATTACHED/DETACHED GARAGE BUILDING PERMIT APPLICATION Community Development 1050 W Romeo Rd Romeoville, IL 60446-1329 (815) 886-7200 Fax #: (815) 886-2724 Email: buildinginspections@romeoville.org ATTACHED/DETACHED GARAGE BUILDING PERMIT APPLICATION Property

More information

City of North Mankato 1001 Belgrade Avenue North Mankato, MN (507)

City of North Mankato 1001 Belgrade Avenue North Mankato, MN (507) City of North Mankato 1001 Belgrade Avenue North Mankato, MN 56003 (507) 625-4141 BUILDING PERMIT GUIDELINES Building Permits are required for all improvements with a value** of $300.00 or more. Sheds,

More information

City of North Mankato 1001 Belgrade Avenue North Mankato, MN (507)

City of North Mankato 1001 Belgrade Avenue North Mankato, MN (507) City of North Mankato 1001 Belgrade Avenue North Mankato, MN 56003 (507) 625-4141 BUILDING PERMIT GUIDELINES Building Permits are required for all improvements with a value** of $300.00 or more. Sheds,

More information

INSPECTION TIMING CHECKLIST FOR RESIDENTIAL FRAME BUILDING PRIOR TO INSPECTION REQUEST

INSPECTION TIMING CHECKLIST FOR RESIDENTIAL FRAME BUILDING PRIOR TO INSPECTION REQUEST Village of Vernon Hills Community Development Department - Building Division 290 Evergreen Drive, Vernon Hills, IL 60061 Phone 847-367-3704 - Fax 847-367-2541 - http://www.vernonhills.org INSPECTION TIMING

More information

$ Plan Review Fee when Permit Application is submitted SHED BUILDING PERMIT APPLICATION. Application Date / /

$ Plan Review Fee when Permit Application is submitted SHED BUILDING PERMIT APPLICATION. Application Date / / Community Development 1050 W Romeo Rd, Romeoville, IL 60446-1530 (815) 886-7200 Fax #: (815) 886-2724 Email: buildinginspections@romeoville.org SHED BUILDING PERMIT APPLICATION Application Date / / Property

More information

The following are exceptions to the use regulations of the district regulations of this ordinance.

The following are exceptions to the use regulations of the district regulations of this ordinance. Article.01 Purpose The purpose of this article is to establish regulations and conditions that are generally applicable to all districts of this Ordinance unless otherwise indicated. It is to provide uniform

More information

CITY OF KIRKWOOD SINGLE FAMILY SITE PLAN WORKSHEET

CITY OF KIRKWOOD SINGLE FAMILY SITE PLAN WORKSHEET S. F. Review No. ZONING DISTRICT PROPERTY ADDRESS CITY OF KIRKWOOD SINGLE FAMILY SITE PLAN WORKSHEET A Missouri Minimum Standards Boundary Survey is required to be filed in support of this worksheet, showing

More information

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE - 268-5161 Residential Accessory Structures This information has been compiled for the benefit of any person

More information

FENCES. This hand out is for REFERENCE ONLY. For more details see specific code sections.

FENCES. This hand out is for REFERENCE ONLY. For more details see specific code sections. Village of Vernon Hills Community Development Department 290 Evergreen Drive, Vernon Hills, IL 60061 Phone 847-367-3704 - Fax 847-367-2541 - http:// www.vernonhills.org FENCES This hand out is for REFERENCE

More information

Fence and Wall Requirements

Fence and Wall Requirements Fence and Wall Requirements Definitions Decorative wall - A wall constructed of stone or other material erected for the sole purpose of providing a decorative and/or landscaped feature, and not to include

More information

RESIDENTIAL BUILDING PLAN REQUIREMENTS

RESIDENTIAL BUILDING PLAN REQUIREMENTS CITY OF MANSFIELD BUREAU OF BUILDING AND CODES 30 NORTH DIAMOND STREET 3RD FLOOR MANSFIELD, OHIO 44902 Phone (419) 755-9688 Fax (419) 755-9453 www.ci.mansfield.oh.us RESIDENTIAL BUILDING PLAN REQUIREMENTS

More information

Residential Decks. NOTE: If you are in a development with a 2. Deck Plan (see below)

Residential Decks. NOTE: If you are in a development with a 2. Deck Plan (see below) Residential Decks A permit is required if the proposed deck will be attached to the dwelling and/or is 30 (or more) off the ground. You must obtain a building permit prior to starting any construction

More information

C ITY OF D ARIEN Community Development Department 1702 Plainfield Road Phone: (630) Fax: (630)

C ITY OF D ARIEN Community Development Department 1702 Plainfield Road Phone: (630) Fax: (630) C ITY OF D ARIEN Community Development Department 1702 Plainfield Road Phone: (630) 353-8115 Fax: (630) 852-4709 BUILDING PERMIT INFORMATION PACKET Revised: October 2018 Building Codes: International Residential

More information

RESIDENTIAL DESIGN GUIDELINES FOR BENT TREE OF ROGERS

RESIDENTIAL DESIGN GUIDELINES FOR BENT TREE OF ROGERS RESIDENTIAL DESIGN GUIDELINES FOR BENT TREE OF ROGERS DATE: October 17, 2000 RESIDENTIAL DESIGN GUIDELINES FOR BENT TREE OF ROGERS INTRODUCTION These Residential Design Guidelines have been approved by

More information

COMMERCIAL OR RESIDENTIAL NEW BUILDINGS, REMODELS AND ADDITIONS

COMMERCIAL OR RESIDENTIAL NEW BUILDINGS, REMODELS AND ADDITIONS COMMERCIAL OR RESIDENTIAL NEW BUILDINGS, REMODELS AND ADDITIONS BUILDING & SAFETY DIVISION (530) 795-4910 ext. 112 or 117 FAX (530) 795-4935 318 First Street Winters, CA 95694 This is a list of the minimum

More information

SECTION R-MH - MANUFACTURED HOUSING RESIDENTIAL DISTRICT.

SECTION R-MH - MANUFACTURED HOUSING RESIDENTIAL DISTRICT. Section 1105 - Page 1 SECTION 1105.09 R-MH - MANUFACTURED HOUSING RESIDENTIAL DISTRICT. 1105.09 SUBD.1. PURPOSE. The purpose of an R-MH Manufactured Housing Residential District is to provide a separate

More information

CITY OF HILSHIRE VILLAGE SWIMMING POOL PLAN SUBMITTAL CHECK LIST ADDRESS: DATE:

CITY OF HILSHIRE VILLAGE SWIMMING POOL PLAN SUBMITTAL CHECK LIST ADDRESS: DATE: CITY OF HILSHIRE VILLAGE SWIMMING POOL PLAN SUBMITTAL CHECK LIST "THE FOLLOWING CHECKLIST IS ONLY A SUMMARY THAT IS PROVIDED FOR THE APPLICANT'S BENEFIT; HOWEVER, FULFILLING THE REQUIREMENTS OF THIS SUMMARY

More information

Section 7: Specifications

Section 7: Specifications Section 7: Specifications 29 31 Building Boundary of Clear Area See Note # 1 8' Shrubs 8' Concrete Pad Equipment 8' TRAVELED WAY M Meter Pedestal 8' Curb Protective Vehicle Posts (Bollards) If Required

More information

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings Building Safety Department 400-2 nd Street South St. Cloud, MN 56301 (320) 255-7239 A building permit is required for any accessory

More information

2003 International Residential Building Code

2003 International Residential Building Code 2003 International Residential Building Code Section R305 Ceiling Height Habitable rooms, hallways, corridors, bathrooms, toilet rooms, laundry rooms and basements shall have a ceiling height of not less

More information

RESIDENTIAL GARAGE AND DRIVEWAY

RESIDENTIAL GARAGE AND DRIVEWAY RESIDENTIAL GARAGE AND DRIVEWAY GENERAL REQUIREMENTS: PERMIT: For new garages or garage additions the fee is $20.00 per hundred square feet or portion thereof ($50 minimum). Demolition permits are $65.00

More information

Building a Wood Deck, Gazebo, or Pergola

Building a Wood Deck, Gazebo, or Pergola Community Development Department 1200 L.W. Besinger Drive - Room 206 Carpentersville, IL 60110 Hours: M-F 8:30 AM 5:00 PM Phone (847) 551-3478 Fax (847) 426-0864 http://vil.carpentersville.il.us Building

More information

Definitions. The following words and phrases, when used in this article, shall have the following meanings respectively ascribed to them:

Definitions. The following words and phrases, when used in this article, shall have the following meanings respectively ascribed to them: Section 10.516 Fences (a) Definitions. The following words and phrases, when used in this article, shall have the following meanings respectively ascribed to them: Adjacent owner shall mean any person

More information

FENCE PERMIT APPLICATION

FENCE PERMIT APPLICATION Department of Building, Zoning & Housing 26789 Highland Road Richmond Heights, Ohio 44143-1429 216-383-6312 Fax: 216-383-6319 richmondheightsohio.org FENCE PERMIT APPLICATION LOCATION OF JOB LOT # SUBDIVISION

More information

Building Regulations; Construction 11

Building Regulations; Construction 11 Building Regulations; Construction 11 b. Ceilings or roofs shall have a minimum of an "R" factor of 12; and c. Where the roof serves also as the finished ceiling a vent space of two inches shall be required

More information

RESIDENTIAL DECK INFOREMATION SHEETS

RESIDENTIAL DECK INFOREMATION SHEETS 2241 221 st Ave. NE East Bethel, MN 55011 Phone: (763) 367-7844 Fax: (763) 434-9578 RESIDENTIAL DECK INFOREMATION SHEETS Building permits Permits required for any deck attached to a structure or any detached

More information

ACCESSORY STRUCTURES (Garages/Sheds) BUILDING AND ZONING REQUIREMENTS (REVISED 4/21/16)

ACCESSORY STRUCTURES (Garages/Sheds) BUILDING AND ZONING REQUIREMENTS (REVISED 4/21/16) ACCESSORY STRUCTURES (Garages/Sheds) BUILDING AND ZONING REQUIREMENTS (REVISED 4/21/16) NOTE: No building permit shall be issued for the construction of more than one (1) detached accessory building on

More information

Section , Article 4 of the Zoning Ordinance December 14, 2012 Page 1 of 8

Section , Article 4 of the Zoning Ordinance December 14, 2012 Page 1 of 8 Page 1 of 8 5.37-1 Fence Regulations (Amended Ordinance 1598 12/23/12) A. Intent: The intent of this section is to provide reasonable regulations for fence installation while allowing property owners the

More information

Oregon Building Officials Association

Oregon Building Officials Association Oregon Building Officials Association Oregon Building Officials Association Inspector s Checklist 2010 Oregon Manufactured Dwelling Installation Specialty Code November 5, 2014 By: Frank Scheer, Building

More information

The Homeowner s Building Application Checklist for Constructing a Residential Addition

The Homeowner s Building Application Checklist for Constructing a Residential Addition The Homeowner s Building Application Checklist for Constructing a Residential Addition This checklist provides homeowners a summary of the Building Permit submission requirements for constructing a residential

More information

Residential Zoning Rules

Residential Zoning Rules Residential Zoning Rules Applications for building permits must contain plans and information that show that the proposal meets the requirements of the International and Washington State building codes,

More information

Basement Build-Out Guidelines

Basement Build-Out Guidelines Community Development Department Five Plaza Drive Woodridge, IL 60517-5014 (630) 719-4750 FAX (630) 719-2900 Basement Build-Out Guidelines The Village of Woodridge requires that a building permit be submitted

More information

THE CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD, NORTH RIDGEVILLE, OHIO TELEPHONE: (440) FAX: (440) Building Department

THE CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD, NORTH RIDGEVILLE, OHIO TELEPHONE: (440) FAX: (440) Building Department 7307 AVON BELDEN ROAD, NORTH RIDGEVILLE, OHIO 44039 TELEPHONE: (440) 353-0822 FAX: (440) 353-0823 INSTRUCTIONS FOR FENCES REQUIREMENTS FOR PERMIT: Completed application form Plot plan showing lot lines,

More information

Single Family Residential Building Permit Questions & Answers

Single Family Residential Building Permit Questions & Answers City Of Edwardsville Public Works Department 200 East Park Street Edwardsville, IL 62025 (618)692-7535 (618)692-7505 Fax Hours: Monday thru Friday 8:00 AM to 5:00 PM Single Family Residential Building

More information

THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER S GUIDE PART I MUNICIPAL BUILDING REQUIREMENTS

THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER S GUIDE PART I MUNICIPAL BUILDING REQUIREMENTS THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER S GUIDE I MUNICIPAL SITE PLAN & LOT GRADING REQUIREMENTS (SUBDIVISION LOTS) Revised: November 18, 2014 1. INTRODUCTION This guide is intended to

More information

Driveways and Other Concrete Slabs

Driveways and Other Concrete Slabs Driveways and Other Concrete Slabs V I L L A G E O F H A N O V E R P A R K F I R E D E PA R T M E N T I certify that I have received a copy of these regulations and will comply with the regulations contained

More information

One and Two Family Additions

One and Two Family Additions One and Two Family Additions An addition to a house, duplex, garage, or an accessory structure requires a building permit prior to performing any construction. Building Department & Permit Office Mon-Fri

More information

ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008)

ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008) ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008) PERMIT SUBMITTAL CHECKLIST: Signed completed Building Permit application form. Two (2) Copies of a Certificate of Survey. Draw to scale the

More information

Solar Photovoltaic System Permit

Solar Photovoltaic System Permit Solar Photovoltaic System Permit Zoning requirements Staff recommends always verifying the zoning requirements for your project before deciding to build. Warrensburg has eleven separate zoning districts,

More information

CHAPTER 4 FENCE REGULATIONS

CHAPTER 4 FENCE REGULATIONS 5-4-1 5-4-2 CHAPTER 4 FENCE REGULATIONS SECTION: 5-4-1: Objective 5-4-2: Definitions 5-4-3: Permits 5-4-4: Limitations 5-4-5: Materials 5-4-6: Temporary Fencing 5-4-7: Swimming Pools, Pools, Hot Tubs and

More information

Two complete sets of plans that are legible and drawn to conventional scale are required to be submitted with the Building Permit Application Form.

Two complete sets of plans that are legible and drawn to conventional scale are required to be submitted with the Building Permit Application Form. The Homeowner s Building Application Checklist for Constructing a Residential Accessory Building This checklist provides homeowners a summary of the Building Permit submission requirements for constructing

More information

THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER S GUIDE PART I MUNICIPAL BUILDING REQUIREMENTS

THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER S GUIDE PART I MUNICIPAL BUILDING REQUIREMENTS THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER S GUIDE I MUNICIPAL SITE PLAN & LOT GRADING REQUIREMENTS (SUBDIVISION LOTS) Revised: July 27, 2017 1. INTRODUCTION This guide is intended to advise

More information

GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches

GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches and shall be sized to carry the applicable roof and

More information

Garage Construction. Permit Guide. Development Center. General Information. Zoning Ordinance Requirements. Building Code Requirements

Garage Construction. Permit Guide. Development Center. General Information. Zoning Ordinance Requirements. Building Code Requirements General Information Site Card. Before starting construction, post the site card (issued by the City) in a front window visible from the street. Miss Dig. Before you dig, call Miss Dig at 800.482.7171 This

More information

LakeRidge Subdivision Design / Architectural Standards

LakeRidge Subdivision Design / Architectural Standards LakeRidge Subdivision Design / Architectural Standards The Architectural Guidelines and Rules shall be a LakeRidge document and shall not be inconsistent with the Covenants, Conditions, and Restrictions,

More information

City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax

City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA 94596 (925) 943-5834 phone (925) 256-3500 fax Issued August 3, 2011 Information Bulletin No. IB-002 Submittal Requirements

More information

Residential Accessory Structures & Room Additions

Residential Accessory Structures & Room Additions Residential Accessory Structures & Room Additions Planning and Development Services Department Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email:

More information

General Requirements for Mobile Homes

General Requirements for Mobile Homes Mobile homes shall conform in all respects to the CAN/CSA-Z240 MH Series of Standards and shall be complete structurally with the entire plumbing, electrical, and heating services installed. Prior to moving

More information

City of St. Peters Residential Deck Guide

City of St. Peters Residential Deck Guide City of St. Peters Residential Deck Guide The city of St. Peters Building Department Deck Guide adheres to the 2015 International Residential Code section R507. A building permit is required before constructing

More information

PENNSAFE BUILDING INSPECTION SERVICES LLC NEW COMMERCIAL BUILDING UCC PLAN REVIEW HANDOUT AND CHECKLIST

PENNSAFE BUILDING INSPECTION SERVICES LLC NEW COMMERCIAL BUILDING UCC PLAN REVIEW HANDOUT AND CHECKLIST PENNSAFE BUILDING INSPECTION SERVICES LLC NEW COMMERCIAL BUILDING UCC PLAN REVIEW HANDOUT AND CHECKLIST Every item below must be checked as completed (if applicable), or marked n/a (if not applicable),

More information

Borough of Doylestown Building and Zoning Department

Borough of Doylestown Building and Zoning Department Borough of Doylestown Building and Zoning Department 57 West Court Street, Doylestown, PA 18901 215.345.4140 RESIDENTIAL BUILDING AND ZONING PERMIT APPLICATION PACKAGE BACKGROUND A building permit is required

More information

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT 1 East Franklin Street Phone: 301-790-4163 Third Floor Hagerstown, MD 21740 Fax: 301-791-2650 BUILDING PERMIT APPLICATION FOR RESIDENTIAL ACCESSORY

More information

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal Roof Size: Width: Length: Roof Type: Gable: Hip: Shed: Roof Pitch: (check one) Trusses: Rafters: Spacing of Trusses or Rafters:

More information

The developer / builder desires to follow the Design Guidelines and Design Features as listed below in lieu of the Basic Standards.

The developer / builder desires to follow the Design Guidelines and Design Features as listed below in lieu of the Basic Standards. Section 2. Single Family and Two Family Guidelines. A. Basic Standard. The developer / builder desires to follow the Design Guidelines and Design Features as listed below in lieu of the Basic Standards.

More information

A UCC Building permit is not required for the exceptions listed below for COMMERCIAL application: (403.42): Building construction for the following:

A UCC Building permit is not required for the exceptions listed below for COMMERCIAL application: (403.42): Building construction for the following: New buildings or renovations to existing buildings for which an application for a permit was made to the Department or a municipality before April 9, 2004. New buildings or renovations to existing buildings

More information

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION Permit No. 175 Beaver Drive, P.O. Box 486 DuBois, PA 15801 Phone: 814-375-1111 Fax: 814-375-1117 Toll Free: 855-PENNSAF LOCATION OF PROPOSED

More information

LINWOOD PARK BUILDING REGULATIONS

LINWOOD PARK BUILDING REGULATIONS Introduction LINWOOD PARK BUILDING REGULATIONS The Linwood Park is owned and operated by the Linwood Park Company as a Family Park. In order to preserve the spirit of Linwood, adjustments have been made

More information

CITY OF LA MARQUE Gateway to the Gulf st St., La Marque, TX (409) Fax: (409)

CITY OF LA MARQUE Gateway to the Gulf st St., La Marque, TX (409) Fax: (409) PROJECT ADDRESS: PERMIT #: DATE: / / FEES DUE:$ ESTIMATED COST OR VALUE: $ FEES PAID: / / PROJECT DISCRIPTION: PROPERTY ID #: PLAN REVIEW NEEDED [ ] YES [ ] NO LOT: BLOCK: SUBDIVISION: SECTION: TOTAL SQFT:

More information

Building Permit Application- Residential Community Development Department 27 Riverside Rd. Riverside, IL P: (708) F: (708)

Building Permit Application- Residential Community Development Department 27 Riverside Rd. Riverside, IL P: (708) F: (708) Building Permit Application- Residential Community Development Department 27 Riverside Rd. Riverside, IL 60546 P: (708) 447 1241 F: (708) 447 2704 Received Stamp GENERAL INFORMATION: Is application to

More information

Wildwood Home Owners Association Architectural Review Board Guidelines

Wildwood Home Owners Association Architectural Review Board Guidelines Wildwood Home Owners Association Architectural Review Board Guidelines A. STATEMENT OF OBJECTIVES : 1. It is the intention of Wildwood Home Owners Association, through this review board, to provide the

More information

BUILDING PERMIT INFORMATION GUIDE FOR THE HOMEOWNER

BUILDING PERMIT INFORMATION GUIDE FOR THE HOMEOWNER THE CORPORATION OF THE MUNICIPALITY OF SOUTH HURON 322 Main Street South, P.O. Box 759, Exeter, Ontario N0M 1S6 PHONE: (519) 235-0310 FAX: (519) 235-3304 TOLL FREE: 1-877-204-0747 WEBSITE: www.southhuron.ca

More information

VILLAGE OF NORTHFIELD (847) BUILDING CONSTRUCTION PERMIT SUBMISSION LIST

VILLAGE OF NORTHFIELD (847) BUILDING CONSTRUCTION PERMIT SUBMISSION LIST VILLAGE OF NORTHFIELD (847) 784-3551 BUILDING CONSTRUCTION PERMIT SUBMISSION LIST ALL PERMITS MUST BE COMPLETED AND SUBMITTED BEFORE PLAN REVIEW. (Applications will NOT be accepted nor building permits

More information

Fence Requirements Permits and Inspections Division 151 W Church Street, Lewisville, Texas Phone: Fence Requirements

Fence Requirements Permits and Inspections Division 151 W Church Street, Lewisville, Texas Phone: Fence Requirements 151 W Church Street, Lewisville, Fence Requirements General Information Any new fence or replacement fence exceeding 20 feet in length requires a permit. If a contractor is used, that contractor must be

More information

THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER'S GUIDE PART I MUNICIPAL BUILDING REQUIREMENTS

THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER'S GUIDE PART I MUNICIPAL BUILDING REQUIREMENTS THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER'S GUIDE I MUNICIPAL SITE PLAN & LOT GRADING REQUIREMENTS (SUBDIVISION LOTS) Revised:March 25,2014 1. INTRODUCTION This guide is intended to advise

More information

COUNTY OF NEVADA BUILDING DEPARTMENT POLICIES

COUNTY OF NEVADA BUILDING DEPARTMENT POLICIES COUNTY OF NEVADA BUILDING DEPARTMENT POLICIES Original Policy: March, 2006 Revised: January 30, 2007 Policy Number: BD-CSC-07-004 Over-The-Counter Permits (Mechanical, Plumbing, Building and Electrical)

More information

MINIMUM REQUIREMENTS FOR CONSTRUCTION PLANS, GRADING AND/OR DRAINAGE PLANS, LOW IMPACT DEVELOPMENT PLANS, AND WATER EFFICIENT LANDSCAPE PLANS

MINIMUM REQUIREMENTS FOR CONSTRUCTION PLANS, GRADING AND/OR DRAINAGE PLANS, LOW IMPACT DEVELOPMENT PLANS, AND WATER EFFICIENT LANDSCAPE PLANS Planning and Community Preservation Department Public Works Department 232 West Sierra Madre Boulevard Sierra Madre, CA 91024 (626)355-7135 MINIMUM REQUIREMENTS FOR CONSTRUCTION PLANS, GRADING AND/OR DRAINAGE

More information

CHAPTER 4. FENCE REGULATIONS (Ordinance No , 07/26/2011)

CHAPTER 4. FENCE REGULATIONS (Ordinance No , 07/26/2011) CHAPTER 4 FENCE REGULATIONS (Ordinance No. 006-2011, 07/26/2011) SECTION: 5-4-1: Objective 5-4-2: Definitions 5-4-3: Permits 5-4-4: Limitations 5-4-5: Materials 5-4-6: Temporary Fencing 5-4-7: Swimming

More information

REGULATIONS FOR RESIDENTIAL OPEN WOOD DECKS

REGULATIONS FOR RESIDENTIAL OPEN WOOD DECKS REGULATIONS FOR RESIDENTIAL OPEN WOOD DECKS TOTAL PERMIT FEE DUE WILL BE $375.00 ($290.00 IS REFUNDABLE AFTER POST HOLE AN FINAL INSPECTION) Furnish (2) copies of a site/plot plan drawn to scale for wood

More information

meters (16 Inches) Transportation (T)

meters (16 Inches) Transportation (T) OFFICE USE ONLY Application # Town of Steady Brook BUILDING AND DEVELOPMENT APPLICATION {All Applications must include copy of Legal Survey, showing all measurements And distances required} {Processing

More information

RESIDENTIAL ADDITION OR ALTERATION PERMIT REQUIREMENTS

RESIDENTIAL ADDITION OR ALTERATION PERMIT REQUIREMENTS P: (847)810-3502 OR (847)810-3503/3521, F: (847)615-4383 RESIDENTIAL ADDITION OR ALTERATION PERMIT REQUIREMENTS The following is required for a complete permit submittal. RESIDENTIAL BUILDING PERMIT, ELECTRIC

More information

Town of Kingsville. Building Department

Town of Kingsville. Building Department Town of Kingsville Building Department GUIDE TO ACCESSORY STRUCTURES AND DECKS FOR BUILDING PERMITS www.kingsville.ca 2017 Disclaimer: The fees and by-law information compiled within this guide are for

More information

CITY OF FATE SINGLE FAMILY BUILDING PERMIT PACKET. Adopted Codes:

CITY OF FATE SINGLE FAMILY BUILDING PERMIT PACKET. Adopted Codes: CITY OF FATE SINGLE FAMILY BUILDING PERMIT PACKET Adopted Codes: 2015 INTERNATIONAL RESIDENTIAL CODE 2015 INTERNATIONAL FUEL GAS CODE 2015 INTERNATIONAL PLUMBING CODE 2015 INTERNATIONAL ENERGY CONSERVATION

More information

Inspection Report. Prepared for: Gil Turiel. Property Address: 545 Briar Run Court Loganville, GA Date: July 17, 2011

Inspection Report. Prepared for: Gil Turiel. Property Address: 545 Briar Run Court Loganville, GA Date: July 17, 2011 Inspection Report Prepared for: Gil Turiel Property Address: Loganville, GA 30052 Date: July 17, 2011 Inspector: Charles Mann (770) 594-2222 www.edificeinspections.com Page 1 INSPECTION CONDITIONS CLIENT

More information

Chapter 8 MINIMUM CONSTRUCTION STANDARDS

Chapter 8 MINIMUM CONSTRUCTION STANDARDS Chapter 8 MINIMUM CONSTRUCTION STANDARDS 4-8-1: ADOPTION OF MINIMUM CONSTRUCTION STANDARDS: 1/5/1 0 In the construction, erection, installation, alteration, repair, location, relocation, replacement to,

More information

City of Friendswood Community Development 910 South Friendswood Drive Friendswood, Texas 77546

City of Friendswood Community Development 910 South Friendswood Drive Friendswood, Texas 77546 CITY OF FRIENDSWOOD POOL REQUIREMENTS THE FOLLOWING ITEMS MUST BE SUBMITTED AS ONE(1) COMPLETE PACKAGE (1) Set of Completed Building, Electrical and Plumbing/Gas Permit Applications Notarized Fencing Letter

More information

EXHIBIT "B-1" DESIGN GUIDELINES SUBDIVISION DESIGN GUIDELINES FOR MELTON RIDGE

EXHIBIT B-1 DESIGN GUIDELINES SUBDIVISION DESIGN GUIDELINES FOR MELTON RIDGE EXHIBIT "B-1" DESIGN GUIDELINES SUBDIVISION DESIGN GUIDELINES FOR MELTON RIDGE DESIGN GUIDELINES SUBDIVISION DESIGN GUIDELINES FOR MELTON RIDGE These Subdivision Design Guidelines are designed specifically

More information

DECK CONSTRUCTION REQUIREMENTS

DECK CONSTRUCTION REQUIREMENTS DECK CONSTRUCTION REQUIREMENTS Should you have any questions after reading the following information, please call the Building Inspection Department at 651-439-4439 to discuss the topics of concern. We

More information

Accessory Building/Detached Building Permit

Accessory Building/Detached Building Permit Accessory Building/Detached Building Permit Zoning requirements Staff recommends always verifying the zoning requirements for your project before deciding to build. Warrensburg has eleven separate zoning

More information

The Compass ( 270 Lisgar Street, Brighton ) Features General Site Work 1. Construction Drawings 2. Building, Plumbing Electrical and Entrance Permits

The Compass ( 270 Lisgar Street, Brighton ) Features General Site Work 1. Construction Drawings 2. Building, Plumbing Electrical and Entrance Permits The Compass ( 270 Lisgar Street, Brighton ) Features General Site Work 1. Construction Drawings 2. Building, Plumbing Electrical and Entrance Permits 3. Development and Septic Fees 4. Tarion New Home Warranty

More information

VILLAGE OF SHAWNEE HILLS 9484 Dublin Rd. Shawnee Hills, Ohio Phone Fax

VILLAGE OF SHAWNEE HILLS 9484 Dublin Rd. Shawnee Hills, Ohio Phone Fax VILLAGE OF SHAWNEE HILLS 9484 Dublin Rd. Shawnee Hills, Ohio 43065 Phone 614-889-2824 Fax 614-336-1791 APPLICATION FOR CERTIFICATE OF ZONING COMPLIANCE Fee Receipt Number Date Property Address: Incomplete

More information

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507) Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN 55046 (507) 744-2327 fax (507) 744-5554 2006 RESIDENTIAL CONSTRUCTION CHECKLIST The following checklist has been designed

More information

RESIDENTIAL ACCESSORY BUILDING SETBACKS. April 17, 2014 Staff Memo

RESIDENTIAL ACCESSORY BUILDING SETBACKS. April 17, 2014 Staff Memo RESIDENTIAL ACCESSORY BUILDING SETBACKS April 17, 2014 Staff Memo P.O. Box 128 125 S. Second Odessa, MO 64076 Phone: (816) 230-5577 Fax: (816) 633-4985 cityofodessamo.com To: Chair McDermed and Planning

More information

RESIDENTIAL DEVELOPMENT GUIDELINES (RF)

RESIDENTIAL DEVELOPMENT GUIDELINES (RF) RESIDENTIAL DEVELOPMENT GUIDELINES (RF) Planning Division DENSITY STANDARDS (MMC 17.12.010) Lot Size (applies to the creation of new lots or lot line adjustments) ZONE MINIMUM LOT AREA MINIMUM LOT WIDTH

More information

PATIOS, STOOPS and PRIVATE WALKWAYS. This hand out is for REFERENCE ONLY. For more details see specific code sections.

PATIOS, STOOPS and PRIVATE WALKWAYS. This hand out is for REFERENCE ONLY. For more details see specific code sections. Village of Vernon Hills Community Development Department 290 Evergreen Drive, Vernon Hills, IL 60061 Phone 847-367-3704 - Fax 847-367-2541 - http://www.vernonhills.org PATIOS, STOOPS and PRIVATE WALKWAYS

More information

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL WARNING Before digging or trenching... Call 811 Indiana Underground Protection Service 1-800-382-5544 AVOID BURIED POWER CABLES 4901 East Park 30 Drive P.O.

More information

20 North Main Alpine, UT (Phone) (Fax) SITE PLAN

20 North Main Alpine, UT (Phone) (Fax)   SITE PLAN Site Plan Instructions New Home Form #1 20 North Main Alpine, UT 84004 801-756-6347 (Phone) 801-756-1189 (Fax) www.alpinecity.org SITE PLAN A detailed site plan, drawn to scale, 1 = 20 min., shall be filed

More information

Inspection requests submitted by 2:30pm will be scheduled for the following business day unless otherwise requested.

Inspection requests submitted by 2:30pm will be scheduled for the following business day unless otherwise requested. Purpose 355 West Queens Road Single Family New Construction Required Inspection Stages Master Requirement GEN 110 Building Department: 604-990-2480, building@dnv.org, fax: 604-984-9683 The following procedure

More information

If a new residence s electrical service is not located within 200 feet of existing

If a new residence s electrical service is not located within 200 feet of existing Primary Line Extensions CHAPTER 4 If a new residence s electrical service is not located within 200 feet of existing primary electrical facilities, a primary line extension is required to place a close

More information

Village of Algonquin

Village of Algonquin Village of Algonquin Community Development Deck Permit Submittal and Construction Requirements Based on the 2006 International Residential Code with Village amendments The requirements herein are the most

More information

1. Complete Building Permit Application forms on page 2. Include septic system design approval from the Washington County Health Department.

1. Complete Building Permit Application forms on page 2. Include septic system design approval from the Washington County Health Department. City of Goshen Instructions for Residential Permit Application Why do you need a building permit? Your home is a large investment, and if your construction project does not comply with the codes adopted

More information

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209) City of Hughson Building Safety Division 7018 Pine Street Hughson, CA 95326 (209) 883-4054 RESIDENTIAL ATTACHED PATIO COVERS Patio covers are one story roofed structures not more than 12 feet above grade,

More information

City of Santa Monica Building and Safety Division

City of Santa Monica Building and Safety Division This is to be used as a general checklist; it is not inclusive of all code requirements and inspection criteria. General requirements Verify that address on permit matched Address, Description and Approvals:

More information

ZONING CLEARANCE PLAN REVIEW CHECKLIST. Based on the Revised Town of Carefree Zoning Ordinance

ZONING CLEARANCE PLAN REVIEW CHECKLIST. Based on the Revised Town of Carefree Zoning Ordinance ZONING CLEARANCE PLAN REVIEW CHECKLIST Based on the Revised Town of Carefree Zoning Ordinance Date: Applicant: Permit Number: Reviewer: Address: Lot & Subdivision: Zoning District: New SRF: Addn/Remodel:

More information

HATFIELD TOWNSHIP DECK/PATIO PERMIT PROCEDURES

HATFIELD TOWNSHIP DECK/PATIO PERMIT PROCEDURES HATFIELD TOWNSHIP DECK/PATIO PERMIT PROCEDURES A deck/patio permit is required for all construction including decks, renovation of existing decks/patio, paver patios, and retaining walls (over 30 inches).

More information