1 4th International Conference on Earthquake Engineering Taipei, Taiwan October 12-13, 26 Paper No. 24 STABILITY OF RHOMBUS MECHANISM DAMPER SYSTEM Fu-Sheng Lin 1, Yung-Feng Lee 2, and Deh-Shiu Hsu 3 ABSTRACT Rhombus mechanism damper system is proposed to be installed in the building structures to reduce the responses of the structures by dissipation energy as the structures subjected to abnormal excitations. A 2-D system is possibly to be damaged by out-of-plane buckling. The system is modeled and analyzed by semi-hinge joint simulated to practical constructing joints to check the critical stiffness of the out-of-plane buckling. It is proved that the proposed mechanism is highly stabilized even it is theoretically an unstable structure. Keywords: rhombus mechanism, damper system, stabilize, out-of-plane buckling. INTRODUCTION Viscous damper is popularly used as an energy dissipation device for the structural passive control purposes. It is needed to induce meaningful relative displacement at the damper connected joints to bring the expected function efficiently. In order to magnify the mentioned relative displacement, rhombus mechanism damper system is proposed (Hsu et al., 24). It is sketched with its displacement diagram in Figure 1(a) and Figure 1(b). According to the rhombus mechanism, relative displacement of the damper ( CD ) to the relative displacement of the joint points ( AB ) of the system allocated on the structure would be magnified when θ< 45 degree. The magnification factor, f, with respect to the angle, θ, can be rationally calculated and plotted in Figure 2. Consequently, the damping force induced by the damper system, F, can be enlarged according to the following equation: θ 2 D 2 D D (1) F= F cot( ) = ff = fcd = f Cd Where F and F D stand for the resisting force induced by the proposed damper system and by the damper itself, respectively; d and d D stand for the relative displacement of the proposed damper system and of the damper itself, respectively; C stands for the damping coefficient of the damper; f stands for the magnifying factor as shown in Figure 2. The proposed rhombus damping system can be allocated in spans of the structures or at corners of structures as indicated in Figure 3(a) and Figure 3(b). 1 Graduate Student, Dept. of Civil Engineering, National Cheng Kung University, Tainan, Taiwan, fredlin@twce.org.tw 2 Ph. D. Student, Dept. of Civil Engineering, National Cheng Kung University, Tainan, Taiwan, lyf_926@hotmail.com.tw 3 Professor, Dept. of Civil Engineering, National Cheng Kung University, Tainan, Taiwan, R.O.C., dshsu@mail.ncku.edu.tw

2 A D D d ' D θ/2 B θ/2 damper θ A A B B d d C d ' C C (a) The system (b) Displacement diagram for rhombus mechanism Figure 1. Rhombus mechanism damper system Magnification factor, f Angle, θ Figure 2. Magnification factor of the rhombus mechanism θ θ1 (a) Allocated in span (b) Allocated at corners Figure 3. Allocation of the rhombus damper system

3 Since all of the connections of the mechanism are easily to be considered as hinge joints, as in a 2-D mechanism, it is no doubt of being inquired about the out-of-plane stability problems. We tried to work the problem by analyzing practical structures allocated with the damper system. Result showing the possibility of the occurrence of the out-of-plane phenomena could be much smaller than we imagined. STABILITY OF THE RHOMBUS DAMPER SYSTEM Once the member connections of the rhombus damper system are considered to be hinge joints, the perpendicular view to the 2-D mechanism (in the direction along the damper) could be modeled as shown in Figure 4(a) (b) and (c). It gives us an unstable structure due to a mode of three hinges co-linear mechanism. If it is in this case, the proposed rhombus damper mechanism will bring nothing help to the structure because the mechanism can not take any load, i.e., can not induce any resisting force, due to the out-of-plane buckling problem. It can be understandable that the mechanism would be stable if the exterior joints are modeled as fixed boundaries as shown in Figure 4(b). Of course, most of the real case in practical applications could be in-between as shown in Figure 4(c), in which semi-hinge joints are represented by rotational springs. Stability capacities can be analyzed numerically in terms of the partial stiffness simulated by the rotational springs. (a) (b) (c) Figure 4. Stability of the mechanism from the view along the direction of the damper NUMERICAL ANALYSIS A joint angle of 3-degree (θ=π/6) is adopted for the rhombus mechanism considered in the analysis. The corresponding magnification factor is f=cos(15 )=3.73. The members for the rhombus mechanism system are designed according to the type of installation form of the system, whether it is a installed to the full span of the frame or it is installed at the corners of the frame. The selected member sizes are listed in Table 1. Table 1. Member size of the rhombus mechanism system. Type of installation To the full span At the corner Tube thickness Diameter Slenderness ratio 1 cm 6 cm ~ 16.5 cm 2.5 cm ~ 15

4 Three story steel frame as shown in Figure 5 is selected as the benchmark structure in the analysis. According to the numerical value provided by NCREE (NCREE, 22), the fundamental natural frequency of the frame is calculated as 1.75Hz with.12m thickness floors of unit weight 65856N/m 3. Acceleration time history of 194 El Centro earthquake is applied as the external excitation. The 1 st mode shape can be calculated and obtain as Φ rj = = (2) Figure 5. Three story benchmark steel frame The inherent damping ratio of the structure is assumed to be 2%. The equivalent damping ratio to be increased by the installation of damper system is assumed to be 18%. In addition, damper used in each individual case is assumed to be identical to each other. The damping coefficient of the damper can be calculated to be C 7324 N-sec/m for the type of installing to full span, and C N-sec/m for the type of installing at corners. For each case of numerical analysis, stiffness of the rotational spring is started from assuming a very big value to simulate a fixed joint condition. Under this assumption, it won t lead to any out-of-plane buckling phenomena. All of the damping resistance induced as expected ideally. The stiffness of the rotational spring is then reduced step by step gradually. At the critical point, it shows the damping resistance dropped suddenly to zero. That means the phenomena of out-of-plane buckling occurred. Special cases for the damper system installed to full span and installed at corners are plotted in Figure 6 and Figure 7 respectively. The spring constant k for the critical points are equal to 75 N/rad and 79 N/rad approximately for each case. When compared to the fix condition, the spring constants are about 14, N/rad and 12, N/rad, the spring constant of 75 N/rad and 79 N/rad is really a very small value. That means the semi-hinge joint even provide just a very little constrain, the system is still remain its working condition, free from out-of-plane buckling. Another example shows the effect of various damping coefficients to the critical spring constant. The calculation result is plotted in Figure 8 and Figure 9, which showing there is no difference to the critical spring constant even different dampers are used in the system. Generally, in most of the examples, even when the stiffness of the rotational spring becomes very small, out-of-plane un-stability won t be occurred for the application of 2-D rhombus mechanism damper system.

5 5 5 Fix 4 4 Damper force (N/m) (a) Damping force vs spring constant. (b) Magnifying depict near the critical point. Figure 6. Example for the damper system installed to full span. 6 6 Fix (a)damping force vs spring constant. (b) Magnifying depict near the critical point. Figure 7. Example for the damper system installed at corners C=15N-sec/m C=1N-sec/m C=7324N-sec/m C=5N-sec/m 2 C=15N-m/sec C=1N-sec/m C=7324N-sec/m C=5N-sec/m (a) Damping force vs spring constant. (b) Magnifying depict near the critical point. Figure 8 Example for the damper system with different dampers are installed to full span.

6 C=3N-sec/m C=25N-sec/m C=21925N-sec/m C=15N-sec/m 2 C=3N-sec/m C=25N-sec/m C=21925N-sec/m C=15N-sec/m (a) Damping force vs spring constant. (b) Magnifying depict near the critical point. Figure 9. Example for the damper system with different dampers are installed at corners. CONCLUSIONS It was raised doubts that a 2-D rhombus mechanism damper system would cause out-of-plane buckling problem. In order to avoid the doubt, 3-D rhombus mechanism damper system was proposed (Hsu et al., 24). However, the work done in this paper showing that even a 2-D rhombus mechanism damper system in practical connection condition, out-of-plane buckling can be occurred only when the connections were made almost idealized to be a hinge connection in the out-of-plane direction. Otherwise, out-of-plane un-stability won t be occurred for the proposed rhombus mechanism damper system applied practically. REFERENCES Deh-Shiu Hsu, Ming-Che Hsu, and Yung-Feng Lee (24), Rhombus Mechanism with Fluid Damper, 13 th World Conference on Earthquake Engineering, Vancouver, Canada, Paper No National Center for Research on Earthquake Engineering (22), Shaking Table and Benchmark Structure of 3D Three Story Steel Frame,

DYNAMIC TEST OF MULTIPLE TUNED MASS DAMPERS FOR VIBRATION CONTROL OF HIGH-RISE BUILDINGS

DYNAMIC TEST OF MULTIPLE TUNED MASS DAMPERS FOR VIBRATION CONTROL OF HIGH-RISE BUILDINGS 1NCEE Tenth U.S. National Conference on Earthquake Engineering Frontiers of Earthquake Engineering July 21-25, 214 Anchorage, Alaa DYNAMIC TEST OF MULTIPLE TUNED MASS DAMPERS FOR VIBRATION CONTROL OF HIGH-RISE

More information

EFFECT OF FLUID VISCOUS DAMPERS IN MULTI-STOREYED BUILDINGS

EFFECT OF FLUID VISCOUS DAMPERS IN MULTI-STOREYED BUILDINGS IMPACT: International Journal of Research in Engineering & Technology (IMPACT: IJRET) ISSN(E): 2321-8843; ISSN(P): 2347-4599 Vol. 2, Issue 9, Sep 2014, 59-64 Impact Journals EFFECT OF FLUID VISCOUS DAMPERS

More information

Full Scale Shaking Table Tests of A Steel Structure with Multi-Curved Buckling Restrained Braces

Full Scale Shaking Table Tests of A Steel Structure with Multi-Curved Buckling Restrained Braces The th World Conference on Earthquake Engineering October -7, 8, Beijing, China Full Scale Shaking Table Tests of A Steel Structure with Multi-Curved Buckling Restrained Braces C. S. Tsai, Wen-Shin Chen,

More information

A MULTI-FUNCTION UNSEATING PREVENTION DEVICE FOR ISOLATED BRIDGES

A MULTI-FUNCTION UNSEATING PREVENTION DEVICE FOR ISOLATED BRIDGES A MULTI-FUNCTION UNSEATING PREVENTION DEVICE FOR ISOLATED BRIDGES Dyi-Wei Chang 1, Tzu-Ying Lee 2, Jaw-Lieh Wang 1 and Jenn-Chuan Lai 1 1 Structrure Enguneering I, CECI Engineering Consultants,Inc., Taiwan,Taipei,

More information

Experimental Study on the Outrigger Damping System for High-Rise Building

Experimental Study on the Outrigger Damping System for High-Rise Building Experimental Study on the Outrigger Damping System for High-Rise Building P. Tan, C.J. Fang, W.R. Tu & F.L. Zhou Guangzhou University, China Y. Wang & M. Jiang Ove Arup & Partners Ltd Shenzhen Branch,

More information

Fluid Viscous Dampers to reduce Wind-induced Vibrations in Tall Buildings

Fluid Viscous Dampers to reduce Wind-induced Vibrations in Tall Buildings Fluid Viscous Dampers to reduce Wind-induced Vibrations in Tall Buildings Abstract R.J. McNamara, SE McNamara / Salvia Inc. 160 Federal Street, 16 th Floor Boston, MA 02110 +1 617 737 0040 Douglas P. Taylor,

More information

Analysis of seismic mitigation elastic-plastic passive control for. continuous beam bridge *

Analysis of seismic mitigation elastic-plastic passive control for. continuous beam bridge * Analysis of seismic mitigation elastic-plastic passive control for continuous beam bridge * QI Xing-jun 1, LI Xiao-jun 2 ( 1 Associate Professor, School of Civil Engineering, Shandong Jianzhu University,

More information

A STUDY ON THE EFFECT OF VERTICAL GROUND ACCELERATION ON THE SEISMIC RESPONSE OF STEEL BUILDINGS

A STUDY ON THE EFFECT OF VERTICAL GROUND ACCELERATION ON THE SEISMIC RESPONSE OF STEEL BUILDINGS 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 2377 A STUDY ON THE EFFECT OF VERTICAL GROUND ACCELERATION ON THE SEISMIC RESPONSE OF STEEL BUILDINGS

More information

SHEAR STRENGTHENING OF REINFORCED CONCRETE FRAMED SHEAR WALLS USING CFRP STRIPS

SHEAR STRENGTHENING OF REINFORCED CONCRETE FRAMED SHEAR WALLS USING CFRP STRIPS SHEAR STRENGTHENING OF REINFORCED CONCRETE FRAMED SHEAR WALLS USING CFRP STRIPS Fu-Pei Hsiao 1, Jih-Ching Wang 2 and Yaw-Jeng Chiou 3 1 Associate research fellow, Center for Research on Earthquake Engineering

More information

SEISMIC CAPACITY ASSESSMENT FOR STREET-FRONT REINFORCED-BRICK BUILDINGS IN TAIWAN

SEISMIC CAPACITY ASSESSMENT FOR STREET-FRONT REINFORCED-BRICK BUILDINGS IN TAIWAN 3 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August -6, 4 Paper No. 75 SEISMIC CAPACITY ASSESSMENT FOR STREET-FRONT REINFORCED-BRICK BUILDINGS IN TAIWAN Pai-Mei LIU, Yi-Hsuan

More information

Using friction dampers for improving earthquake response of self-variable stiffness RC framed buildings

Using friction dampers for improving earthquake response of self-variable stiffness RC framed buildings Using friction dampers for improving earthquake response of self-variable stiffness RC framed buildings I. Iskhakov & Y. Ribakov Department of Civil Engineering, Ariel University Center of Samaria, Israel

More information

ULTIMATE EARTHQUAKE RESISTANT CAPACITY OF CFT-FRAME

ULTIMATE EARTHQUAKE RESISTANT CAPACITY OF CFT-FRAME 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 24 Paper No.2613 ULTIMATE EARTHQUAKE RESISTANT CAPACITY OF CFT-FRAME Motoo SAISHO 1 and Katsuhiko GOTO 2 SUMMARY Seismic

More information

FULL-SCALE VERIFICATION TEST OF DYNAMIC RESPONSE CONTOROL TECHNIQUES FOR STRONG EARTHQUAKES

FULL-SCALE VERIFICATION TEST OF DYNAMIC RESPONSE CONTOROL TECHNIQUES FOR STRONG EARTHQUAKES FULL-SCALE VERIFICATION TEST OF DYNAMIC RESPONSE CONTOROL TECHNIQUES FOR STRONG EARTHQUAKES Hirokazu IEMURA 1, Akira IGARASHI 2, Torajiro FUJIWARA 3 And Akihiro TOYOOKA 4 SUMMARY In order to verify the

More information

PERFORMANCE OF MECHANICAL SEISMIC LOAD TRANSMISSION DEVICE BASED ON IMPACT

PERFORMANCE OF MECHANICAL SEISMIC LOAD TRANSMISSION DEVICE BASED ON IMPACT 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 2517 PERFORMANCE OF MECHANICAL SEISMIC LOAD TRANSMISSION DEVICE BASED ON IMPACT Jae Kwan KIM 1, Min Hyuk

More information

SEISMIC ANALYSIS OF BUILDING USING TWO TYPES OF PASSIVE ENERGY DISSIPATION DEVICES

SEISMIC ANALYSIS OF BUILDING USING TWO TYPES OF PASSIVE ENERGY DISSIPATION DEVICES SEISMIC ANALYSIS OF BUILDING USING TWO TYPES OF PASSIVE ENERGY DISSIPATION DEVICES G.S. Balakrishna 1, Jini Jacob 2 1 (Department of Civil Engineering, SSET/ M G University, India) 2 (Department of Civil

More information

THE APPLICATION OF RESPONSE CONTROL DESIGN USING MIDDLE-STORY ISOLATION SYSTEM TO HIGH-RISE BUILDING

THE APPLICATION OF RESPONSE CONTROL DESIGN USING MIDDLE-STORY ISOLATION SYSTEM TO HIGH-RISE BUILDING 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 3457 THE APPLICATION OF RESPONSE CONTROL DESIGN USING MIDDLE-STORY ISOLATION SYSTEM TO HIGH-RISE BUILDING

More information

COMPARITIVE STUDY OF BASE ISOLATORS AND VISCOUS FLUID DAMPERS ON SEISMIC RESPONSE OF RC STRUCTURES

COMPARITIVE STUDY OF BASE ISOLATORS AND VISCOUS FLUID DAMPERS ON SEISMIC RESPONSE OF RC STRUCTURES International Journal of Civil Engineering and Technology (IJCIET) Volume 9, Issue 8, August 2018, pp. 798 806, Article ID: IJCIET_09_08_081 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=9&itype=8

More information

SEISMIC ENERGY DISSIPATION SYSTEM OF 12-STOREY COUPLED SHEAR WALLS

SEISMIC ENERGY DISSIPATION SYSTEM OF 12-STOREY COUPLED SHEAR WALLS SEISMIC ENERGY DISSIPATION SYSTEM OF 12-STOREY COUPLED SHEAR WALLS Makoto KATO 1, Masaomi TESHIGAWARA 2, Ken-ichi SUGAYA 3 And Yoshiyuki MATSUSHIMA 4 SUMMARY The U.S.-Japan cooperative earthquake research

More information

OPTIMUM INSTALLATION OF VISCOUS LIQUID DAMPERS IN HIGH-RISE BUILDINGS

OPTIMUM INSTALLATION OF VISCOUS LIQUID DAMPERS IN HIGH-RISE BUILDINGS ABSTRACT : OPTIMUM INSTALLATION OF VISCOUS LIQUID DAMPERS IN HIGH-RISE BUILDINGS T. Liu 1, A.Q. Li 2, Z.Q. Zhang 3 and Y.L. Ding 4 1 Doctoral student, School of Civil Engineering, Southeast University,

More information

Chapter 3 Passive Protective Schemes for Rail- Counterweight System

Chapter 3 Passive Protective Schemes for Rail- Counterweight System Chapter 3 Passive Protective Schemes for Rail- Counterweight System The analyses in the previous chapter have shown that the rail-counterweight systems are vulnerable to overstressing of the guide rails

More information

Osamu Takahashi, Hiromasa Aida 1 Junji Suhara, Ryoichiro Matsumoto 2 Yasuo Tsuyuki 3 Takafumi Fujita 4. Kozo Keikaku Engineering 2

Osamu Takahashi, Hiromasa Aida 1 Junji Suhara, Ryoichiro Matsumoto 2 Yasuo Tsuyuki 3 Takafumi Fujita 4. Kozo Keikaku Engineering 2 The th World Conference on Earthquake Engineering October -7, 8, Beijing, China Construction of Civil Building Using Three Dimensional Seismic Isolation System (Part, Design of Building Using Three Dimensional

More information

PERFORMANCE OF TUNED MASS DAMPERS FOR RESPONSE REDUCTION OF STRUCTURES UNDER NEAR-FIELD AND FAR-FIELD SEISMIC EXCITATIONS

PERFORMANCE OF TUNED MASS DAMPERS FOR RESPONSE REDUCTION OF STRUCTURES UNDER NEAR-FIELD AND FAR-FIELD SEISMIC EXCITATIONS 4th International Conference on Earthquake Engineering Taipei, Taiwan October 12-13, 2006 Paper No. 112 PERFORMANCE OF TUNED MASS DAMPERS FOR RESPONSE REDUCTION OF STRUCTURES UNDER NEAR-FIELD AND FAR-FIELD

More information

SEISMIC RESPONSE OF UNSYMMETRIC BUILDING WITH OPTIMALLY PLACED FRICTION DAMPERS

SEISMIC RESPONSE OF UNSYMMETRIC BUILDING WITH OPTIMALLY PLACED FRICTION DAMPERS International Journal of Civil Engineering and Technology (IJCIET) Volume 8, Issue, February 17, pp. 7 88 Article ID: IJCIET_8 8 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=8&itype=

More information

Comparison between Seismic Behavior of Suspended Zipper Braced Frames and Various EBF Systems

Comparison between Seismic Behavior of Suspended Zipper Braced Frames and Various EBF Systems Comparison between Seismic Behavior of Suspended Zipper Braced Frames and Various EBF Systems A. Niknam 1, A. Sharfaei 2 1- Assistant Professor, Civil Engineering Faculty, University of Science & Technology,

More information

REINFORCED CONCRETE WALL BOUNDARY ELEMENT LONGITUDINAL REINFORCING TERMINATION

REINFORCED CONCRETE WALL BOUNDARY ELEMENT LONGITUDINAL REINFORCING TERMINATION 1NCEE Tenth U.S. National Conference on Earthquake Engineering Frontiers of Earthquake Engineering July 1-, 1 Anchorage, Alaska REINFORCED CONCRETE WALL BOUNDARY ELEMENT LONGITUDINAL REINFORCING TERMINATION

More information

EFFECT OF DAMPER ON SEISMIC RESPONSE OF CABLE-STAYED BRIDGE USING ENERGY- BASED METHOD

EFFECT OF DAMPER ON SEISMIC RESPONSE OF CABLE-STAYED BRIDGE USING ENERGY- BASED METHOD International Journal of Civil Engineering and Technology (IJCIET) Volume 9, Issue 2, February 218, pp. 326 339, Article ID: IJCIET_9_2_32 Available online at http://http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=9&itype=2

More information

Soil-Structure Interaction Effects on Building Response in Recent Earthquakes

Soil-Structure Interaction Effects on Building Response in Recent Earthquakes Proceedings Third UJNR Workshop on Soil-Structure Interaction, March 29-3, 24, Menlo Park, California, USA. Soil-Structure Interaction Effects on Building Response in Recent Earthquakes Yasuhiro Hayashi

More information

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE CORE WALL

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE CORE WALL EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE CORE WALL DU Xiu-li 1, JIA Peng 2 And ZHAO Jun 3 1 Professor, College of Architecture and Civil Engineering, Beijing University of Technology,

More information

ANALYTICAL ESTIMATION OF THE EFFECTIVENESS OF TUNED MASS CONTROL SYSTEM USING SHAKING TABLE EXPERIMENTS

ANALYTICAL ESTIMATION OF THE EFFECTIVENESS OF TUNED MASS CONTROL SYSTEM USING SHAKING TABLE EXPERIMENTS 4 th World Conference on Structural Control and Monitoring 4WCSCM-182 ANALYTICAL ESTIMATION OF THE EFFECTIVENESS OF TUNED MASS CONTROL SYSTEM USING SHAKING TABLE EXPERIMENTS Z. Rakicevic A. Zlatevska and

More information

World Academy of Science, Engineering and Technology International Journal of Civil and Environmental Engineering Vol:9, No:4, 2015

World Academy of Science, Engineering and Technology International Journal of Civil and Environmental Engineering Vol:9, No:4, 2015 Investigation on an Innovative Way to Connect RC Beam and Steel Column Ahmed H. El-Masry, Mohamed A. Dabaon, Tarek F. El-Shafiey, Abd El-Hakim A. Khalil Abstract An experimental study was performed to

More information

ON THE SEISMIC UPGRADING OF EXISTING BUILDING BY SEISMIC ISOLATION SYSTEM

ON THE SEISMIC UPGRADING OF EXISTING BUILDING BY SEISMIC ISOLATION SYSTEM 173 ON THE SEISMIC UPGRADING OF EXISTING BUILDING BY SEISMIC ISOLATION SYSTEM I HAYASHI 1, S SHIRINASHIHAMA And Y NAKAJIMA 3 SUMMARY Authors discussed the seismic upgrading of the TEKKEN Co s headquarters

More information

EXPERIMENTAL INVESTIGATION ON THE INTERACTION OF REINFORCED CONCRETE FRAMES WITH PRECAST-PRESTRESSED CONCRETE FLOOR SYSTEMS

EXPERIMENTAL INVESTIGATION ON THE INTERACTION OF REINFORCED CONCRETE FRAMES WITH PRECAST-PRESTRESSED CONCRETE FLOOR SYSTEMS EXPERIMENTAL INVESTIGATION ON THE INTERACTION OF REINFORCED CONCRETE FRAMES WITH PRECAST-PRESTRESSED CONCRETE FLOOR SYSTEMS B.H.H. Peng 1, R.P. Dhakal 2, R.C. Fenwick 3, A.J. Carr 4 and D.K. Bull 5 1 PhD

More information

WIRE-ROPE BRACING SYSTEM WITH ELASTO-PLASTIC DAMPERS FOR SEISMIC RESPONSE REDUCTION OF STEEL FRAMES

WIRE-ROPE BRACING SYSTEM WITH ELASTO-PLASTIC DAMPERS FOR SEISMIC RESPONSE REDUCTION OF STEEL FRAMES The 4 th World Conference on Earthquake Engineering October -7, 8, Beijing, China WIRE-ROPE BRACING SYSTEM WITH ELASTO-PLASTIC AMPERS OR SEISMIC RESPONSE REUCTION O STEEL RAMES X. Hou and H. Tagawa Graduate

More information

Parametric Studies on Tuned Liquid Damper by Horizontal Shake Table Experiments

Parametric Studies on Tuned Liquid Damper by Horizontal Shake Table Experiments IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 12, Issue 5 Ver. V (Sep. - Oct. 2015), PP 41-47 www.iosrjournals.org Parametric Studies on Tuned

More information

NLTHA and Pushover Analysis for Steel Frames with Flag-shaped Hysteretic Braces

NLTHA and Pushover Analysis for Steel Frames with Flag-shaped Hysteretic Braces NLTHA and Pushover Analysis for Steel Frames with Flag-shaped Hysteretic Braces J.B. McInerney University of Cambridge, UK J.C. Wilson McMaster University, Canada SUMMARY: In this study, non-linear time

More information

Analysis of Lateral Loads for a Framed Model with Tuned Liquid Damper

Analysis of Lateral Loads for a Framed Model with Tuned Liquid Damper Analysis of Lateral Loads for a Framed Model with Tuned Liquid Damper Namrata Yannawar (P.G. Student, Department of Civil Engineering, Rajashri Shahu College of Engineering, Pune, India) Abstract: Earthquake

More information

SEISMIC RESPONSE OF MULTISTOREYED STEEL FRAME WITH VISCOUS FLUID SCISSOR JACK DAMPERS

SEISMIC RESPONSE OF MULTISTOREYED STEEL FRAME WITH VISCOUS FLUID SCISSOR JACK DAMPERS International Journal of Civil Engineering and Technology (IJCIET) Volume 8, Issue 8, August 2017, pp. 289 312, Article ID: IJCIET_08_08_032 Available online at http://http://ww www.iaeme.com/ijciet/issues.asp?jtype=ijciet&v

More information

Overview of Presentation. SCBFs are Conceptually Truss Structures

Overview of Presentation. SCBFs are Conceptually Truss Structures Ultimate Strength and Inelastic Behavior of Braced Frame Gusset Plate Connections Charles W. Roeder University of Washington Department of Civil and Environmental Engineering Seattle, WA 98195 Structural

More information

EXPERIMENTAL VALIDATION OF THE STRUCTURAL FUSE CONCEPT

EXPERIMENTAL VALIDATION OF THE STRUCTURAL FUSE CONCEPT EXPERIMENTAL VALIDATION OF THE STRUCTURAL FUSE CONCEPT R.E. Vargas 1 and M. Bruneau 2 1 Assistant Professor, Dept. of Civil Engineering, Technological University of Panama, Panama 2 Professor, Dept. of

More information

Seismic Control of Continuous Bridges Using Variable Radius Friction Pendulum Systems and Viscous Fluid Dampers

Seismic Control of Continuous Bridges Using Variable Radius Friction Pendulum Systems and Viscous Fluid Dampers Seismic Control of Continuous Bridges Using Variable Radius Friction Pendulum Systems and Viscous Fluid Dampers A. Krishnamoorthy Department of Civil Engineering, Manipal Institute of Technology, Manipal,

More information

EXPERIMENTAL STUDY ON LOAD CAPACITIES OF ISOLATED HEAVY-DUTY SCAFFOLDS USED IN CONSTRUCTION

EXPERIMENTAL STUDY ON LOAD CAPACITIES OF ISOLATED HEAVY-DUTY SCAFFOLDS USED IN CONSTRUCTION Advanced Steel Construction Vol. 10, No. 3, pp. 248-273 (2014) 248 EXPERIMENTAL STUDY ON LOAD CAPACITIES OF ISOLATED HEAVY-DUTY SCAFFOLDS USED IN CONSTRUCTION Jui-Lin Peng 1,*, Chung-Ming Ho 2, Chenyu

More information

EFFECTS OF COLUMN CAPACITY ON THE SEISMIC BEHAVIOR OF MID-RISE STRONG-COLUMN-WEAK-BEAM MOMENT FRAMES

EFFECTS OF COLUMN CAPACITY ON THE SEISMIC BEHAVIOR OF MID-RISE STRONG-COLUMN-WEAK-BEAM MOMENT FRAMES EFFECTS OF COLUMN CAPACITY ON THE SEISMIC BEHAVIOR OF MID-RISE STRONG-COLUMN-WEAK-BEAM MOMENT FRAMES Nattapat WONGPAKDEE and Sutat LEELATAVIWAT ABSTRACT The strong-column-weak-beam (SCWB) design philosophy

More information

ANALYSIS OF A SQUAT CONCRETE WALL, DIFFERENCE IN TRANSLATION DURING SEISMIC EXCITATION DUE TO FOUNDATION SUPPORT. ABSTRACT

ANALYSIS OF A SQUAT CONCRETE WALL, DIFFERENCE IN TRANSLATION DURING SEISMIC EXCITATION DUE TO FOUNDATION SUPPORT. ABSTRACT ANALYSIS OF A SQUAT CONCRETE WALL, DIFFERENCE IN TRANSLATION DURING SEISMIC EXCITATION DUE TO FOUNDATION SUPPORT. E. R. Thorhallsson 1, I. S. Rikhardsson 2, A.M. Olafsson 3 and H.S. Olafsson 4 ABSTRACT

More information

Seismic Behaviour Of A Soft Storey Building With & Without Viscous Dampers

Seismic Behaviour Of A Soft Storey Building With & Without Viscous Dampers RESEARCH ARTICLE OPEN ACCESS Seismic Behaviour Of A Soft Storey Building With & Without Viscous Dampers Yuvraj Bisht*, Saraswati Setia** *(Department of Civil Engineering, NIT Kurukshetra, Haryana, INDIA

More information

A Full-Scale Experimental Study on Seismic Behaviour of Vibration Isolated Mechanical/Electrical Equipment

A Full-Scale Experimental Study on Seismic Behaviour of Vibration Isolated Mechanical/Electrical Equipment Proceedings of the Ninth Pacific Conference on Earthquake Engineering Building an Earthquake-Resilient Society 14-16 April, 211, Auckland, New Zealand A Full-Scale Experimental Study on Seismic Behaviour

More information

Seismic Assessment of Traditional Masonry-Wooden Building in Taiwan

Seismic Assessment of Traditional Masonry-Wooden Building in Taiwan Seismic Assessment of Traditional Masonry-Wooden Building in Taiwan Yu-Chun Lin, Ja-Shian Chang, To-Nan Chen & Chung-Hsien Shih Department of Architecture, National Cheng Kung University, Taiwan SUMMARY:

More information

The th World Conference on Earthquake Engineering October -7, 8, Beijing, China These buildings contain by 7, and column lines and spaced m in both x

The th World Conference on Earthquake Engineering October -7, 8, Beijing, China These buildings contain by 7, and column lines and spaced m in both x The th World Conference on Earthquake Engineering October -7, 8, Beijing, China INVESTIGATION OF FLOOR RIGIDITY EFFECT ON BEHAVIOR OF STEEL BRACED FRAMES SHAHABODIN. ZAREGARIZI. M.S, Dept. of Civil Engineering,

More information

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online): IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online): 2321-0613 Experimental Investigation of Effect of Tuned Mass Damper in the Structure using Shake

More information

Effective Length of RC Column with Spandrel Wall

Effective Length of RC Column with Spandrel Wall Effective Length of RC Column with Spandrel Wall *Eun-Lim Baek 1), and Sang-Hoon Oh 2) and Sang-Ho Lee 3) 1), 2) Department of Architectural Engineering, Pusan National University, Busan 69-735, Korea

More information

EFFICIENCY OF USING VISCOUS DAMPERS FOR MULTI-STOREY STEEL STRUCTURES SUBJECTED TO SEISMIC ACTIONS

EFFICIENCY OF USING VISCOUS DAMPERS FOR MULTI-STOREY STEEL STRUCTURES SUBJECTED TO SEISMIC ACTIONS 11 th International Conference on Vibration Problems Z. Dimitrovová et al. (eds.) Lisbon, Portugal, 9-12 September 213 EFFICIENCY OF USING VISCOUS DAMPERS FOR MULTI-STOREY STEEL STRUCTURES SUBJECTED TO

More information

Dual earthquake resistant frames

Dual earthquake resistant frames Earthquake Resistant Engineering Structures VII 165 Dual earthquake resistant frames T. L. Sophocleous & M. C. Phocas Department of Civil and Environmental Engineering, University of Cyprus, Cyprus Abstract

More information

Response Behaviour of a Three Storied Framed Structure with Tuned Liquid Damper

Response Behaviour of a Three Storied Framed Structure with Tuned Liquid Damper Response Behaviour of a Three Storied Framed Structure with Tuned Liquid Damper Namrata Yannawar 1, G.R.Patil 2 P.G. Student, Department of Civil Engineering, Rajashri Shahu College of Engineering, Pune,

More information

Damage Concentration in Multi-Story Buckling Restrained Braced Frame (BRBF) Relations with participant ratioβof BRB-

Damage Concentration in Multi-Story Buckling Restrained Braced Frame (BRBF) Relations with participant ratioβof BRB- The th World Conference on Earthquake Engineering October -,, Beijing, China Damage Concentration in Multi-Story Buckling Restrained Braced Frame (BRBF) Relations with participant ratioβof BRB- ABSTRACT:

More information

A DEVELOPMENT OF A NEW TECHNOLOGY FOR BASE-ISOLATED BUILDINGS USING CROSSED LINEAR BEARINGS

A DEVELOPMENT OF A NEW TECHNOLOGY FOR BASE-ISOLATED BUILDINGS USING CROSSED LINEAR BEARINGS 008 A DEVELOPMENT OF A NEW TECHNOLOGY FOR BASE-ISOLATED BUILDINGS USING CROSSED LINEAR BEARINGS Fumiaki ARIMA 1, Toru SUZUKI, Norikatsu TAKASE And Hiroyuki HARADA 4 SUMMARY This paper presents the new

More information

HYBRID MOMENT RESISTING STEEL FRAMES

HYBRID MOMENT RESISTING STEEL FRAMES HYBRID MOMENT RESISTING STEEL FRAMES Finley A. Charney 1 and Ozgur Atlayan 2 1 Associate Professor, Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, 2461, USA 2 Graduate

More information

A Comparison between a New Semi-Active Tuned Mass Damper and an Active Tuned Mass Damper

A Comparison between a New Semi-Active Tuned Mass Damper and an Active Tuned Mass Damper Available online at www.sciencedirect.com Procedia Engineering 14 (2011) 2779 2787 The Twelfth East Asia-Pacific Conference on Structural Engineering and Construction A Comparison between a New Semi-Active

More information

Performance Improvement of Tall Reinforced Concrete Structures with Multiple Tuned Mass Dampers (MTMD)

Performance Improvement of Tall Reinforced Concrete Structures with Multiple Tuned Mass Dampers (MTMD) Performance Improvement of Tall Reinforced Concrete tructures with Multiple Tuned Mass Dampers (MTMD) M. hooshtari Department of Civil Eng., Bu Ali ina University, Hamedan, Iran. H. Mortezaie Department

More information

Cyclic Loading Tests Of Steel Dampers Utilizing Flexure-Analogy of Deformation

Cyclic Loading Tests Of Steel Dampers Utilizing Flexure-Analogy of Deformation Cyclic Loading Tests Of Steel Dampers Utilizing Flexure-Analogy of Deformation J.-H. Park & K.-H. Lee University of Incheon, Korea SUMMARY Steel dampers utilizing flexure analogy of deformation are proposed

More information

COMPRESSIVE BEHAVIOR OF BUCKLING-RESTRAINED BRACE GUSSET CONNECTIONS

COMPRESSIVE BEHAVIOR OF BUCKLING-RESTRAINED BRACE GUSSET CONNECTIONS COMPRESSIVE BEHAVIOR OF BUCKLING-RESTRAINED BRACE GUSSET CONNECTIONS MIN-LANG LIN 1), KEH-CHYUAN TSAI 2), PO-CHIEN HSIAO 3),and CHENG-YU TSAI 4) 1) National Center for Research on Earthquake Engineering,

More information

DYNAMIC ANALYSIS OF 25 STOREY RCC BUILDING WITH AND WITHOUT VISCOUS DAMPERS. Naziya Ghanchi1, Shilpa Kewate2

DYNAMIC ANALYSIS OF 25 STOREY RCC BUILDING WITH AND WITHOUT VISCOUS DAMPERS. Naziya Ghanchi1, Shilpa Kewate2 International Journal of Scientific & Engineering Research, Volume 6, Issue 12, December-215 DYNAMIC ANALYSIS OF 25 STOREY RCC BUILDING WITH AND WITHOUT VISCOUS DAMPERS Naziya Ghanchi1, Shilpa Kewate2

More information

ctbuh.org/papers Evaluation of Progressive Collapse Resisting Capacity of Tall Buildings Title:

ctbuh.org/papers Evaluation of Progressive Collapse Resisting Capacity of Tall Buildings Title: ctbuh.org/papers Title: Authors: Subject: Keywords: Evaluation of Progressive Collapse Resisting Capacity of Tall Buildings Kwangho Kim, Sungkyunkwan University Seromi Park, Sungkyunkwan University Jinkoo

More information

A new approach for the Seismic Isolation Methods for Ancient Statues Displayed in Base Isolated Museums

A new approach for the Seismic Isolation Methods for Ancient Statues Displayed in Base Isolated Museums A new approach for the Seismic Isolation Methods for Ancient Statues Displayed in Base Isolated Museums C.A Castiglioni, A. Kanyilmaz Politecnico di Milano, Italy SUMMARY: In order to protect the precious

More information

REVIEW AND ASSESS THE OPTIMAL ARRANGEMENT OF VISCOUS DAMPERS IN ORDER TO REDUCE THE SEISMIC RESPONSE OF TALL REINFORCED CONCRETE STRUCTURES

REVIEW AND ASSESS THE OPTIMAL ARRANGEMENT OF VISCOUS DAMPERS IN ORDER TO REDUCE THE SEISMIC RESPONSE OF TALL REINFORCED CONCRETE STRUCTURES REVIEW AND ASSESS THE OPTIMAL ARRANGEMENT OF VISCOUS DAMPERS IN ORDER TO REDUCE THE SEISMIC RESPONSE OF TALL REINFORCED CONCRETE STRUCTURES Ashkan Vafaei Msc Students of Structure Faculty of Engineering,

More information

SEISMIC PERFORMANCE OF CONCRETE TILT-UP BUILDINGS: CURRENT WALL-TO-SLAB CONNECTIONS

SEISMIC PERFORMANCE OF CONCRETE TILT-UP BUILDINGS: CURRENT WALL-TO-SLAB CONNECTIONS SEISMIC PERFORMANCE OF CONCRETE TILT-UP BUILDINGS: CURRENT WALL-TO-SLAB CONNECTIONS Frank Devine, 1 Omri Olund, 2 Ken Elwood 3 and Perry Adebar 4 1 Graduate Student, Dept. of Civil Engineering, University

More information

Seismic Model Test of a Hybrid High-rise Building in Shanghai

Seismic Model Test of a Hybrid High-rise Building in Shanghai ctbuh.org/papers Title: Authors: Subject: Keywords: Seismic Model Test of a Hybrid High-rise Building in Shanghai Wensheng Lu, Associate Professor, Tongji University Xilin Lu, Professor, Tongji University

More information

USING ACCORDION THIN-WALLED TUBE AS A HYSTERETIC METALLIC DAMPER

USING ACCORDION THIN-WALLED TUBE AS A HYSTERETIC METALLIC DAMPER 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 2264 USING ACCORDION THIN-WALLED TUBE AS A HYSTERETIC METALLIC DAMPER Mehrtash MOTAMEDI 1, Fariborz NATEGHI-A.

More information

LIGHTLY DAMPED MOMENT RESISTING STEEL FRAMES

LIGHTLY DAMPED MOMENT RESISTING STEEL FRAMES ABSTRACT : LIGHTLY DAMPED MOMENT RESISTING STEEL FRAMES Ozgur Atlayan and Finley A. Charney Graduate Student, Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, 46, USA Email:

More information

Development of Experimental Benchmark Problems for International Collaboration in Structural Response Control

Development of Experimental Benchmark Problems for International Collaboration in Structural Response Control Development of Experimental Benchmark Problems for International Collaboration in Structural Response Control Chin-Hsiung Loh 1), Anil K. Agrawal 2), Jerome P. Lynch 3) and Jann N. Yang 4) 1) Dept. of

More information

RESPONSE OF GROUND SUPPORTED CYLINDRICAL TANKS TO HARMONIC LOADING

RESPONSE OF GROUND SUPPORTED CYLINDRICAL TANKS TO HARMONIC LOADING RESPONSE OF GROUND SUPPORTED CYLINDRICAL TANKS TO HARMONIC LOADING Asha Joseph 1 and Glory Joseph 2 1 Research Scholar, Cochin University of Science and Technology, Kerala 2 Associate Professor, Cochin

More information

RESPONSE CONTROL BY DAMPER DEVICES OF HIGH-RISE BUILDING UNDER LONG-PERIOD GROUND MOTION

RESPONSE CONTROL BY DAMPER DEVICES OF HIGH-RISE BUILDING UNDER LONG-PERIOD GROUND MOTION RESPONSE CONTROL BY DAMPER DEVICES OF HIGH-RISE BUILDING UNDER LONG-PERIOD GROUND MOTION Miguel Augusto DIAZ FIGUEROA 1 Supervisor: Taiki Saito 2 MEE71 ABSTRACT This study attempts to apply Performance

More information

Integrated Optimal Life Cycle Design of Super Tall Buildings with Viscous Dampers

Integrated Optimal Life Cycle Design of Super Tall Buildings with Viscous Dampers 11 th World Congress on Structural and Multidisciplinary Optimisation 07 th -12 th, June 2015, Sydney Australia Integrated Optimal Life Cycle Design of Super Tall Buildings with Viscous Dampers Xin Zhao

More information

Structural Engineering, Mechanics, and Materials. Preliminary Exam - Structural Design

Structural Engineering, Mechanics, and Materials. Preliminary Exam - Structural Design Fall Semester 2018 Preliminary Exam - Structural Design A small building is located in downtown Berkeley. The structural system, either structural steel or reinforced concrete, comprises gravity framing

More information

Behavior and Performance of Structures Equipped With ADAS & TADAS Dampers (a Comparison with Conventional Structures)

Behavior and Performance of Structures Equipped With ADAS & TADAS Dampers (a Comparison with Conventional Structures) Behavior and erformance of Structures Equipped With & T Dampers (a Comparison with Conventional Structures) Seyed Masoud Sajjadi Alehashem 1, Ali Keyhani, and Hassan ourmohammad 3 1 Research Scholar, Dept.

More information

Effect of plastic hinge, soil nonlinearity and uplift on earthquake energy in structures

Effect of plastic hinge, soil nonlinearity and uplift on earthquake energy in structures Effect of plastic hinge, soil nonlinearity and uplift on earthquake energy in structures M. Sarrafzadeh, E. Lim, X. Qin & N. Chouw Department of Civil and Environmental Engineering, the University of Auckland,

More information

Experimental Study on Seismic Performance of Equipment with Vibration Isolation Devices

Experimental Study on Seismic Performance of Equipment with Vibration Isolation Devices Experimental Study on Seismic Performance of Equipment with Vibration Isolation Devices Fan-Ru Lin, Jenn-Shin Hwang, Min-Fu Chen, Shiang-Jung Wang NCREE (National Center for Research on Earthquake Engineering),

More information

Concept improvement of behavior of X-Bracing systems by using Easy-Going Steel

Concept improvement of behavior of X-Bracing systems by using Easy-Going Steel Concept improvement of behavior of X-Bracing systems by using Easy-Going Steel S. Sabouri-Ghomi 1 and P. Ebadi 2 1 Associate Prof., Dept. of Structural Engineering, haje Nasir Toosi University of Technology,

More information

An investigation into the influence of friction damper device on the performance of steel moment frames

An investigation into the influence of friction damper device on the performance of steel moment frames American Journal of Engineering Research (AJER) e-issn : 2320-0847 p-issn : 2320-0936 Volume-03, Issue-03, pp-230-237 www.ajer.org Research Paper Open Access An investigation into the influence of friction

More information

FRICTION-BASED SLIDING BETWEEN STEEL AND STEEL, STEEL AND CONCRETE, AND WOOD AND STONE

FRICTION-BASED SLIDING BETWEEN STEEL AND STEEL, STEEL AND CONCRETE, AND WOOD AND STONE FRICTION-BASED SLIDING BETWEEN STEEL AND STEEL, STEEL AND CONCRETE, AND WOOD AND STONE Peng-Cheng Zhang 1, Takuya Nagae 2, Jason McCormick 3, Masahiro Ikenaga 4, Mika Katsuo 4, Masayoshi Nakashima 5 1

More information

REHABILITATION OF RC BUILDINGS USING STRUCTURAL WALLS

REHABILITATION OF RC BUILDINGS USING STRUCTURAL WALLS REHABILITATION OF RC BUILDINGS USING STRUCTURAL WALLS Ahmed GHOBARAH 1 And Maged YOUSSEF 2 SUMMARY A developed macroscopic model is applied to the analysis of an example structure to demonstrate the use

More information

OPTIMUM DESIGN OF TMD SYSTEM FOR TALL BUILDINGS

OPTIMUM DESIGN OF TMD SYSTEM FOR TALL BUILDINGS INTERNATIONAL JOURNAL OF OPTIMIZATION IN CIVIL ENGINEERING Int. J. Optim. Civil Eng., 2012; 2(4):511-532 OPTIMUM DESIGN OF TMD SYSTEM FOR TALL BUILDINGS A. Abdelraheem Farghaly *, Faculty of Industrial

More information

Inelastic Torsional Response of Steel Concentrically Braced Frames

Inelastic Torsional Response of Steel Concentrically Braced Frames Inelastic Torsional Response of Steel Concentrically Braced Frames R. Comlek, B. Akbas & O. Umut Gebze Institute of Technology, Gebze-Kocaeli, Turkey J. Shen & N. Sutchiewcharn Illinois Institute of Technology,

More information

Study of seismic effect on buildings modified with shear wall

Study of seismic effect on buildings modified with shear wall Study of seismic effect on buildings modified with shear wall Hingkam Dada, Zuhail Bin Basheer T.P,Bullo Apo, Shaheel Ahammed 1234B.Tech Student, Civil Engineering, Mar Athanasius college of engineeringe,kerala,

More information

Dynamic Time History Analysis of Plane Frame with Tuned Mass Considering Soil-Structure Interaction

Dynamic Time History Analysis of Plane Frame with Tuned Mass Considering Soil-Structure Interaction ١ Dynamic Time History Analysis of Plane Frame with Tuned Mass Damper by Considering Soil-Structure Interaction S. M. Mirhoseini hezaveh Civil Engineering Department, Islamic Azad University Arak Branch

More information

DYNAMIC CHARACTERISTICS ASSESSMENT OF STEEL BEAM-COLUMN CONNECTIONS WITH FLOOR SLAB

DYNAMIC CHARACTERISTICS ASSESSMENT OF STEEL BEAM-COLUMN CONNECTIONS WITH FLOOR SLAB 10NCEE Tenth U.S. National Conference on Earthquake Engineering Frontiers of Earthquake Engineering July 21-25, 2014 Anchorage, Alaska DYNAMIC CHARACTERISTICS ASSESSMENT OF STEEL BEAM-COLUMN CONNECTIONS

More information

MID-STORY SEISMIC ISOLATION FOR STRENGTHENING OF A MULTI-STORY BUILDING

MID-STORY SEISMIC ISOLATION FOR STRENGTHENING OF A MULTI-STORY BUILDING 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 1443 MID-STORY SEISMIC ISOLATION FOR STRENGTHENING OF A MULTI-STORY BUILDING Jiandong ZHOU 1, Ming HU

More information

Vibration Control by Tuned Liquid Dampers

Vibration Control by Tuned Liquid Dampers Vibration Control by Tuned Liquid Dampers Motive Construction of tall structures in regions around the world where earthquakes and extreme-wind conditions take place have been a concern to structural engineers.

More information

VALLIAMMAI ENGINEERING COLLEGE DEPARTMENT OF CIVIL ENGINEERING SUBJECT CODE: CE6701 SUBJECT NAME: STRUCTURAL DYNAMICS AND EARTHQUAKE ENGINEERING YEAR : IV SEM : VII QUESTION BANK (As per Anna University

More information

EARTHQUAKE RESPONSE ANALYSIS OF MID-STORY BUILDINGS ISOLATED WITH VARIOUS SEISMIC ISOLATION TECHNIQUES

EARTHQUAKE RESPONSE ANALYSIS OF MID-STORY BUILDINGS ISOLATED WITH VARIOUS SEISMIC ISOLATION TECHNIQUES EARTHQUAKE RESPONSE ANALYSIS OF MID-STORY BUILDINGS ISOLATED WITH VARIOUS SEISMIC ISOLATION TECHNIQUES N. Torunbalci 1 and G. Ozpalanlar 2 1 Assoc. Professor Dr., Dept. of Structural Engineering, Faculty

More information

Seismic performance of skew bridge with friction type rubber bearings

Seismic performance of skew bridge with friction type rubber bearings The 4 th World Conference on Earthquake Engineering October -7, 8, Beijing, China Seismic performance of skew bridge with friction type rubber bearings K.Y. Liu, K.C. Chang, C.H. Lu 3 and W.C. Cheng 4

More information

Performance-based plastic design of a high rise moment resisting frame with friction dampers

Performance-based plastic design of a high rise moment resisting frame with friction dampers Earthquake Resistant Engineering Structures X Performance-based plastic design of a high rise moment resisting frame with friction dampers C. S. Patil, V. B. Patil & S. B. Kharmale B. V. B. College of

More information

On the dynamic response of hardening systems

On the dynamic response of hardening systems Earthquake Resistant Engineering Structures VII 217 On the dynamic response of hardening systems O. Sircovich Saar Principal of Sircovich Saar Engineering, Israel Abstract This paper relates to hardening

More information

SHAKING TABLE TEST USING MULTIPURPOSE TEST BED

SHAKING TABLE TEST USING MULTIPURPOSE TEST BED October 12-17, 28, Beijing, China SHAKING TABLE TEST USING MULTIPURPOSE TEST BED Toru Takeuchi 1, Kazuhiko Kasai 2, Mitsumasa Midorikawa 3, Yuichi Matsuoka 4, Takeshi Asakawa 5, Isao Kubodera 6, Yuji Kurokawa

More information

Application of Isolation Technology in High-voltage Electrical Equipments

Application of Isolation Technology in High-voltage Electrical Equipments Application of Isolation Technology in High-voltage Electrical Equipments WEN Bo 1 AND ZHANG Jun-fa 2, NIU Di-tao 3 1 Doctoral Candidate, Dept. of Civil Engineering, Xi an University of Architecture &

More information

Simplified Finite Element Modelling of Multi-storey Buildings: The Use of Equivalent Cubes

Simplified Finite Element Modelling of Multi-storey Buildings: The Use of Equivalent Cubes Electronic Journal of Structural Engineering (8) 28 Simplified Finite Element ling of Multi-storey Buildings: The Use of Equivalent Cubes B. Li, C. F. Duffield & G. L. Hutchinson University of Melbourne,

More information

Seismic Response of High-rise RC Brace Frame Structure Using Energy Dissipation Braces

Seismic Response of High-rise RC Brace Frame Structure Using Energy Dissipation Braces Seismic Response of High-rise RC Brace Frame Structure Using Energy Dissipation Braces *Heran Lee 1), Taishi Shiraishi 1), Yusuke Maida 2) and Nobuyuki Izumi 3) 1), 2), 3) Department of Architecture, Chiba

More information

SEISMIC DESIGN OF STRUCTURE

SEISMIC DESIGN OF STRUCTURE SEISMIC DESIGN OF STRUCTURE PART I TERMINOLOGY EXPLANATION Chapter 1 Earthquake Faults Epicenter Focal Depth Focus Focal Distance Epicenter Distance Tectonic Earthquake Volcanic Earthquake Collapse Earthquake

More information

IJREISS Volume2, Issue 6(June 2012) ISSN: SEISMIC ANALYSIS OF CUBIC BURIED TANKS REGARDING SOIL STRUCTURE INTERACTION

IJREISS Volume2, Issue 6(June 2012) ISSN: SEISMIC ANALYSIS OF CUBIC BURIED TANKS REGARDING SOIL STRUCTURE INTERACTION SEISMIC ANALYSIS OF CUBIC BURIED TANKS REGARDING SOIL STRUCTURE INTERACTION Yasin Moradi PhD. Student, School of Civil Engineering, College of Engineering, University of Tehran, Iran Prof. Khosrow Bargi

More information

SEISMIC RESPONSE ANALYSIS OF A SEMI-ACTIVE-CONTROLLED BASE-ISOLATED BUILDING DURING THE 2011 GREAT EAST JAPAN EARTHQUAKE

SEISMIC RESPONSE ANALYSIS OF A SEMI-ACTIVE-CONTROLLED BASE-ISOLATED BUILDING DURING THE 2011 GREAT EAST JAPAN EARTHQUAKE Proceedings of the International Symposium on Engineering Lessons Learned from the 2 Great East Japan Earthquake, March -4, 22, Tokyo, Japan SEISMIC RESPONSE ANALYSIS OF A SEMI-ACTIVE-CONTROLLED BASE-ISOLATED

More information

Dynamic Analysis of High Rise Flat Plate Building with Different Retrofitting Systems

Dynamic Analysis of High Rise Flat Plate Building with Different Retrofitting Systems EUROPEAN ACADEMIC RESEARCH Vol. I, Issue 11/ February 2014 ISSN 2286-4822 www.euacademic.org Impact Factor: 3.1 (UIF) DRJI Value: 5.9 (B+) Dynamic Analysis of High Rise Flat Plate Building with Different

More information

Seismic Damage-Resistant System for Multi-Storey Modular Light Steel Framed Buildings

Seismic Damage-Resistant System for Multi-Storey Modular Light Steel Framed Buildings Seismic Damage-Resistant System for Multi-Storey Modular Light Steel Framed Buildings John Jing 1 and G. Charles Clifton 2 1. Structural Engineer, BSc., BE Civil (Hons.) and PhD (Civil), Harrison Grierson

More information