Internal Partitions - Timber Studs Internal Partitions - Steel Stud
|
|
- Audra Iris Quinn
- 5 years ago
- Views:
Transcription
1 Timber Studs PH Internal Partitions - Steel Stud / hour fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm PROMATECT -H boards, each side mm thick Mineral wool, raw density kg/m, 0mm thick Mineral wool seal Timber stud mm x 0mm at 0mm spacing Timber rail 0mm long round head nails at nominal 00mm centres M steel anchor bolt at nominal 00mm centres Concrete wall or floor slab hour fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm PROMATECT -H boards, each side mm thick Mineral wool, raw density kg/m, 0mm thick Mineral wool seal Timber stud mm x 0mm at 0mm spacing Timber rail 0mm long round head nails at nominal 00mm centres or 0mm x No. screws at nominal 00mm centres Installation Method M steel anchor bolt at nominal 00mm centres Concrete wall or floor slab / hours fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm PROMATECT -H boards, each side mm thick Mineral wool, raw density 00 kg/m, 0mm thick Mineral wool seal Timber stud mm x 0mm at 0mm spacing Timber rail 0mm long round head nails at nominal 00mm centres or 0mm x No. screws at nominal 00mm centres M steel anchor bolt at nominal 00mm centres Concrete wall or floor slab Detail Elevation Detail Vertical section A-A Detail Horizontal section B-B hours fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm PROMATECT -H boards, each side mm thick Mineral wool, raw density 00 kg/m, 0mm thick applied in layers of 0mm thickness with all joints staggered between layers Mineral wool seal Timber stud mm x 0mm at 0mm spacing Timber rail mm long round head nails at nominal 00mm centres or mm x No. screws at nominal 00mm centres M steel anchor bolt at nominal 00mm centres Concrete wall or floor slab NOTE: The above construction details can be installed up to m high. Details for walls above m high are available on request.
2 Steel Stud Internal Partitions - Steel Studs PH/PMF / hour fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm Sound transmission class: STC PROMATECT -H boards, each side mm thick or PROMINA 0 boards, each side mm thick PROMATECT -H strips 0mm wide, each side mm thick or PROMINA 0 strips 00mm wide, each side mm thick Mineral wool, raw density kg/m by 0mm thick or none if using PROMINA 0 mm thick boards Mineral wool seal (optional) Steel stud 0mm deep x 0.mm thick at 0mm spacing Ceiling and floor perimeter steel channel 0mm deep x 0.mm thick M self-tapping screws at nominal 00mm centres M steel anchor bolt at nominal 00mm centres Installation Method Concrete wall or floor slab hour fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm Sound transmission class: STC PROMATECT -H boards, each side mm thick or PROMINA 0 boards, each side mm thick PROMATECT -H strips 0mm wide, each side mm thick or PROMINA 0 strips 00mm wide by mm thick Mineral wool, raw density kg/m by 0mm thick or 0 kg/m by 0mm thick Mineral wool seal (optional) Steel stud 0mm deep x 0.mm thick at 0mm spacing Ceiling and floor perimeter steel channel 0mm deep x 0.mm thick M self-tapping screws at nominal 00mm centres M steel anchor bolt at nominal 00mm centres Concrete wall or floor slab Detail Elevation (continued on next page)
3 Steel Stud Internal Partitions - Steel Studs PH/PMF (continued from previous page) hours fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm Sound transmission class: STC PROMATECT -H boards, each side mm thick PROMATECT -H strips 00mm wide, each side mm thick Mineral wool, raw density 0 kg/m by 0mm thick or 0 kg/m by 0mm thick applied in layers with all joints staggered between layers Mineral wool seal (optional) Steel stud 0mm deep x 0.mm thick at 0mm spacing Ceiling and floor perimeter steel channel 0mm deep x 0.mm thick M self-tapping screws at nominal 00mm centres Detail Vertical section A-A M steel anchor bolt at nominal 00mm centres Concrete wall or floor slab NOTE: The above partitions are approved for heights up to m using framing members as detailed, these constructions are approved for heights up to m with slight construction amendments, please consult Promat technical department for details. Detail 0 0 minutes rating for integrity only in accordance with the relevant criteria of BS : Part can be met using a construction utilising similar steel studs as detailed above, with a single layer of mm PROMATECT fi -H fixed onto one face only. Please note that the board should be placed on the fire risk side as this construction is not symmetrical. Steel stud partitions constructed using minimum mm PROMATECT -H fulfill the relevant criteria of BS with regard to impact resistance, stiffness etc. Please consult your local Promat office for construction details. Detail Horizontal section B-B
4 Steel Stud Internal Partitions - Steel Studs PH/PMF hours fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm PROMINA 0 board, each side mm thick a Fire rated gypsum board, each side mm thick Mineral wool seal a Steel stud mm x mm x 0.mm at 0mm centres Ceiling and floor perimeter steel channel mm x mm x 0.mm M self-tapping screws at nominal 00mm centres M steel anchor bolt at nominal 00mm centres Concrete floor slab or wall hours fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm Sound transmission class: STC PROMATECT -H boards, each side layers x mm thick with the horizontal and vertical joints between boards staggered by a minimum of 00mm Installation Method Mineral wool seal Steel stud 00mm x 0mm x.mm at 00mm centres Ceiling and floor perimeter steel channel 00mm x 0mm x.mm M self-tapping screws at nominal 00mm centres M steel anchor bolt at nominal 00mm centres Concrete floor slab or wall Mineral wool, raw density 0 kg/m, 00mm thick applied in layers of 0mm thickness with all joints staggered between layers a Detail Vertical section Detail a Detail Horizontal section hours fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm Sound transmission class: STC PROMATECT -H boards, each side layers x mm thick with the horizontal and vertical joints between boards staggered by a minimum of 00mm Mineral wool seal Steel stud 00mm x 0mm x.mm at 00mm centres Ceiling and floor perimeter steel channel 00mm x 0mm x.mm M self-tapping screws at nominal 00mm centres M steel anchor bolt at nominal 00mm centres Concrete floor slab or wall Mineral wool, raw density 0 kg/m, 00mm thick applied in layers of 0mm thickness with all joints staggered between layers NOTE: The vertical joints between boards will not necessarily coincide with the steel studs, and therefore the two layers of boards should be stitched together using mm dry wall type screws at nominal 00mm centres. NOTE: The above partitions are approved for heights up to m using framing members as detailed, these constructions are approved for heights up to m with slight construction amendments, please consult Promat technical department for details.
5 Solid Partition PH Solid Partitions hour fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm PROMATECT -H boards, 0mm + mm Stagger joints by at least 00mm, fix 0mm layer first Steel angle frame 0mm x 0mm x mm M steel anchor bolt at nominal 00mm centres Self tapping screws or similar First layer 0mm, fixed to perimeter angle using 0mm x No. screws, at 00mm centres. Second layer mm, fixed to first layer using 0mm x No. screws at 00mm centres around the perimeter and down the centre of each panel. Take care not to overturn screws Concrete wall or floor slab / hours fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm PROMATECT -H boards, 0mm + 0mm Stagger joints by at least 00mm Steel angle frame 0mm x 0mm x mm M steel anchor bolt at nominal 00mm centres Self tapping screws or similar First layer fixed to perimeter angle using 0mm x No. screws at 00mm centres. Second layer fixed to first layer using mm x No. screws at 00mm centres around the perimeter and down the centre of each panel. Take care not to overturn screws Concrete wall or floor slab hours fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm PROMATECT -H boards, 0mm + mm + mm or x mm Stagger joints by at least 00mm, fix 0mm layer first Steel angle frame 0mm x 0mm x mm M steel anchor bolt at nominal 00mm centres Self tapping screws or similar First layer 0mm, fixed to perimeter angle using 0mm x No. screws at 00mm centres. Second layer mm, fixed to first layer using 0mm x No. screws at 00mm centres around the perimeter and down the centre of each panel. Third layer mm, fixed to first two layers using mm x No. screws at 00mm centres around the perimeter and down the centre of each panel. Take care not to over tighten screws Concrete wall or floor slab hours fire rating, integrity in accordance with the criteria of BS : Part, and AS 0: Part with Insulation Criteria of 0 and 0 minutes. Nominal thickness of partition: mm or mm For 0 minutes insulation: PROMATECT -H 0mm + 0mm, stagger joints by at least 00mm For 0 minutes insulation: PROMATECT -H mm + mm, Stagger joints by at least 00mm Steel angle frame 0mm x 0mm x mm M steel anchor bolt at nominal 00mm centres Self tapping screws or similar First layer fixed to perimeter angle using 0mm x No. screws at 00mm centres. Second layer fixed to first layer using mm x No. screws at 00mm centres around the perimeter and down the centre of each panel. Take care not to overturn screws Concrete wall or floor slab Installation Method Detail Vertical section Detail Detail Horizontal section NOTE: The above construction details are applicable for up to.m high. Details for walls above.m high are available on request.
6 Solid Partition PH Solid Partitions hours fire rating, integrity and insulation in accordance with the criteria of ASTM E. First layer: PROMATECT -H board, mm thick Second layer: PROMATECT -H board, mm thick Third layer: PROMATECT -H board, mm thick Fourth layer: PROMATECT -H board, mm thick Self-drilling bugle head screw fastener No. x 0mm mm x mm staples at 0mm centres Galvanised steel angle mm x mm x.mm NOTE: The above construction details are applicable for up to.m high. Details for walls above.m high are available on request. Installation Method Detail Vertical section Detail Detail Horizontal section
7 Shaft Wall Partition PMF Solid Partitions The following system is applicable for use in those areas where the full integrity and insulation performance is required, but where access for construction is possible from one side only (e.g. Lift shafts etc). This construction is designed to fulfil the criteria of the relevant standards relating to the compartmentation of lift shafts, and to provide resistance to positive and negative pressures resulting from the movements of the elevators etc. The below details are suitable for wall heights of up to 000mm between substrates. For construction to greater heights, please consult Promat Technical Department. hour and hours fire rating, integrity and insulation in accordance with the criteria of BS : Part : PROMINA 0 board, mm thick I-studs 0mm x mm x 0.mm at 0mm intervals 0 Stud 0mm x 0mm x 0.mm at edge of shaft wall partition Stud 0mm x 0mm x 0.mm as top and bottom track Installation Method PROMINA 0 filler strips, mm thick x mm wide PROMINA 0 cover strips, mm thick x 00mm wide at joints hour fire rating: Mineral wool 0mm thick x kg/m hours fire rating: Mineral wool mm thick x 00 kg/m hour fire rating: PROMINA 0 cover strips, x mm thick x 00mm wide hours fire rating: PROMINA 0 cover strips, x mm thick x 00mm wide PROMINA 0 board, mm thick Detail Vertical section Detail 0 Self-tapping or self-drilling screws at 00mm centres Threaded rod with nuts and washers at 00mm centres NOTE: Steel stud partitions constructed using minimum mm PROMATECT -H fulfill the relevant criteria of BS with regard to impact resistance, stiffness etc. Please consult your local Promat office for construction details. 0 Detail Horizontal section
8 Single Side Partition PH Suspe nded Ceilings hours fire rating, integrity only in accordance with the criteria of BS : Part with fire from board side. PROMATECT -H boards, mm thick Steel stud 0mm x mm x 0.mm thick at 0mm centres Ceiling and floor perimeter steel channel 0mm x mm x 0.mm thick fastened to concrete with M steel anchors at 00mm centres M self-tapping screws at nominal 00mm centres Installation Method hours fire rating, integrity only in accordance with the criteria of BS : Part with fire from board side. PROMATECT -H boards, layers x mm thick Steel stud mm x mm x 0.mm thick at 0mm centres Ceiling and floor perimeter steel channel 0mm x mm x 0.mm thick fastened to concrete with M steel anchors at 00mm centres M self-tapping screws at nominal 00mm centres NOTE: The construction detailed herein is suitable for heights up to.m. These systems can be installed for heights up to m. Please consult Promat Technical Department for details of the framing members required to achieve greater heights. Installation Method
PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Cavity & Smoke Barriers, Parapet & Spandrel Walls
PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Cavity & Smoke Barriers, Parapet & Spandrel Walls For Promat Asia Pacific Organisation February 0 PASSIVE FIRE PROTECTION SYSTEMS Application
More informationElectrical & Mechanical Services Enclosures - Designer Selector Table
Designer Selector Table 8 Electrical & Mechanical Services Enclosures Integrity & Insulation Product Fire Rating Collar Size Mineral Wool VICUCLAD or VICUTUBE 0mm thick 0/0/0 80mm x 0mm thick mm x kg/m
More informationCERTIFICATE OF APPROVAL No CF 429 PROMAT UK LTD
CERTIFICATE OF APPROVAL No CF 429 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of The Sterling Centre,
More informationThe Passive Fire Protection Handbook
The Passive Fire Protection Handbook The UK s comprehensive guide to passive fire protection Chapter Ceilings, Floors and Roofs AUGUST 0 The Passive Fire Protection Handbook Contents Chapter : Introduction
More informationPASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ductwork
PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ductwork For Promat Asia Pacific Organisation February 0 Ductwork General Information i Steel duct claddings inside the Changi Water Reclamation
More informationDivision 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 11
07 21 16 Blanket Insulation Page 1 of 11 Unifrax I LLC Design No. UNI/BI 120-14 FIRE RESISTANT GREASE DUCT FyreWrap Elite 1.5 Duct Insulation ASTM E 2336-16 and ICC-ES Acceptance Criteria for Grease Duct
More informationDuct Wrap Flexible Wraps
Design No. 3MU/ 60-01 December 23, 2010 VENTILATION DUCT PROTECTION 3M Company 3M Fire Barrier Duct Wraps: 615 and 615+ 3M Fire Barrier Sealants: Water-Tight 1000-NS Silicone, Water-Tight 1003-SL Silicone
More informationCERTIFICATE OF APPROVAL No CF 422 PROMAT UK LTD
CERTIFICATE OF APPROVAL No CF 422 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of The Sterling Centre,
More informationPROMAtect H 4 hour walls. progressivematerials.com.au
PROMAtect H 4 hour walls 08 9445 8300 info@progressivematerials.com.au progressivematerials.com.au Partitions General Information Introduction Partitions and external walls are used to separate buildings,
More informationMetal Web Floor System
Metal Web Floor System Contents Contents Introduction and benefits 3 easi-joist definitions 4 easi-joist webs 5-6 Mechanical services 7 Loading and design 8 Floor stiffness 9 Internal non-loadbearing wall
More informationDivision 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 17
07 21 16 Blanket Insulation Page 1 of 17 Design Number UNI/BI 120-03 FIRE RESISTANT GREASE DUCT Unifrax I LLC FyreWrap Elite 1.5 Duct Insulation CAN/ULC S144 Fire Resistance Rating 2 hours Fire Inside
More informationPROMATECT hour walls
PROMATECT 100 2 hour walls 08 9445 8300 info@progressivematerials.com.au progressivematerials.com.au Partitions General Information Introduction Partitions and external walls are used to separate buildings,
More informationPROMATECT 100 Solid Partitions
PROMATECT 100 Solid Partitions 08 9445 8300 info@progressivematerials.com.au progressivematerials.com.au Partitions General Information Introduction Partitions and external walls are used to separate buildings,
More informationFIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250
FIRE PROTECTION GTEC Shaftwall range uses a specially designed system to protect voids and shafts in buildings. It resists pressure changes and enables installation from one side of the shaft only. GTEC
More informationPROMAtect h concrete upgrade Concrete and brick walls
PROMAtect h concrete upgrade Concrete and brick walls 08 9445 8300 info@progressivematerials.com.au progressivematerials.com.au Concrete Upgrading Systems Index 112 Type of System Increase of Concrete/brick
More informationHOW TO: CREATE METAL PARTITIONS WALL LININGS AND CEILINGS GTEC FRAMES
HOW TO: CREATE METAL PARTITIONS WALL LININGS AND CEILINGS GTEC FRAMES 1 METAL OR TIMBER? When creating stud partitions, wall linings and suspended ceilings the traditional method of installation has been
More informationPROMATECT 100 Passive Fire Protection Building & Construction Solutions
PROMATECT 00 Passive Fire Protection Building & Construction Solutions www.promat.com.au Solely for distribution in Australia Ceilings and floors Ceilings & floors system index Ceiling type Fire resistance
More informationBXUV.V481. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263
Page Bottom BXUV.V481 Fire Resistance Ratings - ANSI/UL 263 Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements
More informationPROMATECT -H External Wall With Mineral Wool
External Walls General Information Introduction There is a recognised need to prevent fire leaping from one building to an adjacent location. The rush of fire could therefore be from within or without
More informationPROMATECT -H Access Panels & Hatches.
Access Panels & Hatches www.promat-ap.com Access Panels & Hatches General Information Terminology The term Panel or Panels describes wall or ceiling access panels that are used for periodic maintenance
More informationAdjustable Suspension Hanger Technical Datasheet
Adjustable Suspension Hanger sheet The Adjustable Suspension Hangers Clip are a component of the Keylock Ceiling System. The upper vertical side of the hanger allows the Suspension Rod that goes through
More informationContents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2
Contents BCA Codes 3 General 4 Fire Performances Thermal and Acoustic Insulation Wall Installation 4 Timber Frame Separation Walls 5 Steel Frame Separation Walls 6 External Fire Rated Walls 7 Floor Installation
More informationPARTITIONS & EXTERNAL WALLS 5
PARTITIONS & EXTERNAL WALLS INTERNAL PARTITIONS CONVERSION OF EXTERNAL WALL TO INTERNAL WALL TECHNICAL DATA 30 minutes fire rating, integrity and insulation in accordance with the criteria of BS 7: Part
More informationFEATURES APPLICATIONS. Technical data sheet SSW - STEEL STRONG-WALL FOR TIMBER FRAME RACKING RESISTANCE.
The Steel Strong-Wall is a corrugated steel panel which is designed to be fixed directly to the concrete foundations of a building, within the external or internal wall, via a bolted connection. FEATURES
More informationTECHNICAL DATA SHEET. fire protective board, reinforced full-core plasterboard
Firetect page 1/5 product description intended use certification Firetect P - field of application fire protective board, reinforced full-core plasterboard fireboard to protect elements to be used for
More informationUL Design System HW-D-1012 continued
UL System No. HW-D-1012 Assembly Ratings 1, 2 and 3 Hr (See Item 2) Nominal Joint Width 3 in. Class II and III Movement Capabilities 100% Compression or Extension Page 1 of 5 1. Floor Assembly The fire-rated
More informationInstallation. Resilmount A237R. Installation Instructions. Furring channel sound isolation clip
Resilmount A237R Furring channel sound isolation clip Installation Instructions Another Quality Building Product Installation A237R SPECIFICATIONS Width: 1-3/8 eight (including rubber): 1-1/16 Length:
More informationJune Non - Residential New Build Partition walls
June 2010 Non - Residential New Build 4.6.3 Partition walls Non-residential new build 4.0 Non-residential New Build Partition Walls Contents Introduction find online page Solution optimiser and pathfinder
More informationPROMAtect 50 Structural steel. progressivematerials.com.au
PROMAtect 50 Structural steel 08 9445 8300 info@progressivematerials.com.au progressivematerials.com.au STRUCTURAL STEEL FIRE PROTECTION PROMATECT 50 Cement Bound Matrix Board General Information 3 Definition
More informationPromaseal pillows. progressivematerials.com.au
Promaseal pillows 08 9445 8300 info@progressivematerials.com.au progressivematerials.com.au PROMASEAL PILLOWS VARIOUS PENETRATION SEALS IN FLOORS, WALLS & PARTITIONS SP 81.18 82.18 PROMASEAL Pillows are
More informationNot to be distributed outside of FM Global except by Customer
Not to be distributed outside of FM Global except by Customer APPROVAL REPORT APPROVAL OF HILTI CABLE TRANSIT SYSTEM CFS-T FOR USE IN WALL AND FLOOR ASSEMBLIES RATED UP TO AND INCLUDING 2 HOURS Prepared
More informationI-STUD Shaftwall System
I-STUD Shaftwall System Summit Tower I-Stud and CertainTeed Shaftliner TM MILL CERTIFIED Steel-Con 00% GALVANIZED Steel Construction Systems UL Evaluation Report No. ER3660-02 Intertek The I-Stud is approved
More informationKnauf C-Form Suspended Ceilings
Knauf C-Form Suspended Ceilings The Knauf C-Form Suspended Ceiling system uses the minimum number of different components and is extremely easy and quick to install. The system is very strong and perfect
More informationNortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1
16 May 2014 Page 1 PART 1 GENERAL 1.1 DESCRIPTION This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories
More informationFireWall. High performance fire-resistant wall system. FireWall.
FireWall FireWall High performance fire-resistant wall system FireWall is a non-loadbearing wall which provides up to 240 minutes fire resistance. It is used in certain ground floor basement situations
More informationInstruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips)
SOUND ISOLATION CLIPS Installation Manual Instruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips) SOUND ISOLATION CLIP SPECIFICATIONS Width...1.00 inch Height...1.06 inch Length...3.86
More informationKemwell Impact Board. PASSIVE FIRE PROTECTION Specialists for the construction, infrastructure, transport, energy, industrial and commercial sectors.
Uniclass L68111:P91 CI/SfB Ry September 2017 Epic F811 (K2) Kemwell Impact Board A1 Non-combustible high performance fire, blast and impact protection board for critical applications in the commercial,
More informationSECTION SOUND ISOLATION
SECTION 13085 SOUND ISOLATION PART 1 GENERAL 1.1 SECTION INCLUDES A. Resilient sound isolation clips installed with drywall furring channels for support of gypsum board for noise control (de-coupling)
More informationVentura Office Partitions. Technical guide
Office Partitions Technical guide - General Despite its minimalistic and sleek design, is a genuine, relocatable office partition in line with other products in the Triplan system. This relocatable office
More informationSECTION GYPSUM BOARD
SECTION 09250 GYPSUM BOARD PART 1GENERAL 1.1 SUMMARY A. Related Documents: General and Supplementary Conditions of the Contract, Division 1 - General Requirements, and Drawings are collectively applicable
More informationFIRE RESISTANT GLAZING SYSTEMS 8
FIRE RESISTANT GLAZING SYSTEMS Traditionally glass has been the last material architects think of when specifying fire barriers. New technologies are turning this traditional thinking on its head. Glass
More informationrobustdetails E-FC-7 Separating Floor Concrete Separating Floors Concrete E-FC-7
DO Butt floor blocks tightly together Cover floor blocks with min 50mm concrete topping Ensure that concrete does not enter the cavity and bridge the two leaves of supporting wall blockwork - it is acceptable
More informationPart E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,
Part E Pack Dear Colleague, This is the first 2017 update to the Part E Robust Details Handbook. In this update pack, we have focussed on clarifying the situation on incorporating underfloor heating (UFH)
More informationFIRE RATING MATERIAL FIXING NOTES
FIRE RATING MATERIAL FIXING NOTES FIRE RATING MATERIAL FIXING NOTES... 1 External Wall Systems... 2 Non load bearing steel stud walls... 3 LOAD-BEARING STEEL STUD WALLS... 3 NON LOAD-BEARING TIMBER STUD
More informationVoie Romaine F Maizières-lès-Metz Tel.: +33 (0) Fax.: +33 (0) Operating vacuum pressure: - 500Pa
Voie Romaine F-57280 Maizières-lès-Metz Tel.: +33 (0)3 87 51 11 11 Fax.: +33 (0)3 87 51 10 58 CLASSIFICATION REPORT CLASSIFICATION REPORT no. 09 - A - 363 According to standards EN 15650: 2010 and EN 13501-3:
More informationCavity ShAftwall System
09 9 00/NGC Cavity shaftwall systems are non-load-bearing, -hour to -hour, fire-rated partitions constructed from one side used to enclose elevator shafts, stairs and mechanical shafts where the design
More informationIntertenancy Barrier Systems for Terrace Homes
Intertenancy Barrier Systems for Terrace Homes Specification & Installation Manual CBI5113 NATIONAL SUPPORT VISIT: POST: Winstone Wallboards Limited 37 Felix Street, Penrose, Auckland 1061, New Zealand
More informationThe Passive Fire Protection Handbook
The Passive Fire Protection Handbook The UK s comprehensive guide to passive ire protection Chapter Fire Rated Ductwork and Service Enclosures AUGUST 07 The Passive Fire Protection Handbook Contents Chapter
More informationCERTIFICATE OF APPROVAL No CF 5073 LEMINAR AIR CONDITIONING INDUSTRIES L.L.C.
CERTIFICATE OF APPROVAL No CF 5073 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of PO Box 33539, Dubai,
More informationPROMATECT -H Double Layer Steel Stud Partitions
PROMATECT -H Double Layer Steel Stud Partitions Partitions General Information Introduction Partitions and external walls are used to separate buildings, enclose compartments and contain fire to provide
More informationPROMATECT -S Smoke & Fire Barrier
PROMATECT -S Smoke & Fire Barrier Introduction The purpose of a cavity barrier is to prevent the spread of smoke and flame from penetrating and/or moving within a concealed space in a fire compartment.
More informationREPORT HOLDER: KINETICS NOISE CONTROL 6300 IRELAN PLACE DUBLIN, OHIO EVALUATION SUBJECT: KINETICS NOISE CONTROL WAVE HANGER
0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3207 Reissued 10/2016 This report is subject to renewal 10/2018. DIVISION: 09 00 00 FINISHES
More informationInstallation Guide and Safety Manual Resilient Sound Isolation Clips (SIC Clips)
Installation Guide and Safety Manual Resilient Sound Isolation Clips (SIC Clips) SOUND ISOLATION CLIP SPECIFICATIONS Width...1.00 inch Height...1.06 inch Length...3.86 inch Weight....025 lbs Max Spacing...48
More informationCavity fire barriers. Cavity fire barriers. Fire separation within concealed spaces. C06 Floors and ceilings
Fire separation within concealed spaces Regulatory requirements demand that cavities and concealed spaces, in the structure or fabric of a building, are sub-divided or sealed by means of cavity barriers
More informationLEGACY REPORT ER ICC Evaluation Service, Inc. Reissued October 1, Legacy report on the 1997 Uniform Building Code
LEGACY REPORT Reissued October 1, 2007 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900 Montclair
More informationProduct Guide Specification
PAC International, Inc. January 2004 PO Box 5369 Aloha, Oregon 97006 Toll Free (866) RSIC-100 (866) 774-2100 PAC Phone (503) 649-7700 Fax (503) 649-2710 INTERNATIONAL Inc. Web Site www.pac-intl.com E-Mail
More informationInstallation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips)
Installation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips) 3" RESILMOUNT A237R SPECIFICATIONS 1d " f" Width...1.375 inch Height...3.25 inch Depth...1.125 inch Weight....025
More informationA. AISI Specifications for Design of Cold-Formed Steel Structural Members
Section 13 48 00: Sound, Vibration, and Seismic Control PART 1: GENERAL 1.1 SECTION INCLUDES A. SonusClip resilient sound isolation clips installed with drywall furring channel for support of gypsum board
More informationPROMATECT -H Single Sided Steel Stud Partition
PROMATECT -H Single Sided Steel Stud Partition Partitions General Information Introduction Partitions and external walls are used to separate buildings, enclose compartments and contain fire to provide
More informationI-STUD Shaftwall System
I-STUD Shaftwall System Summit Tower Spokane, WA I-Stud and CertainTeed Shaftliner MILL CERTIFIED 00% GALVANIZED UL Evaluation Report No. ER3660-02 Intertek SCAFCO I-Stud is approved with the following
More informationXHBN.FF-D Joint Systems. Joint Systems. System No. FF-D-3008
XHBN.FF-D-3008 - Page 1 of 2 XHBN.FF-D-3008 Page Bottom See General Information for System No. FF-D-3008 March 20, 2006 Assembly Rating 2 Hr Nominal Joint Widths 14, 16, 18 and 20 In. (See Item 2A) Class
More informationThis page was. intentionally. left blank
CONSTRUCTION Measurement of Airborne Sound Insulation of 8 Wall Assemblies Measurement of Airborne and Impact Sound Insulation of 29 Floor Assemblies Nordic Engineered Wood Report No. A1-006070.10 July
More informationPROMATECT fi 250 PROMAXON fi Technology Steelwork Fire Protection
PROMATECT fi 250 PROMAXON fi Technology Steelwork Fire Protection A NEW GENERATION OF FIRE PROTECTION BOARDS PROMATECT fi 250 PROMAXON fi Technology Steelwork Fire Protection 01/02 PROMATECT fi 250 is
More informationProduct Guide Specification
PAC International, Inc. December 2007 Las Vegas, NV 89128 Toll Free (866) RSIC-100 (866) 774-2100 Fax (866) 649-2710 Web Site www.pac-intl.com E-Mail info@pac-intl.com Product Guide Specification Specifier
More informationGypWall AUDIO The ultimate sound insulating wall system
The ultimate sound insulating wall system Cineworld, Ilford 8 The ultimate sound insulating wall system is a non-loadbearing, twin frame high performance wall system that provides exceptionally high levels
More information1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights
1 Exam Prep Application and Finishing of Gypsum Board GA-216-2013 Tabs and s These 1 Exam Prep Tabs are based on the Gypsum Association GA-216-2013 Application and Finishing of Gypsum Panel Products. Each
More informationThe System U.S. Patent No. 5,913,788
The System U.S. Patent No. 5,913,788 UL System No. HW-D-0027 2 Hour Rated Assembly (Metal Decking) UL System No. HW-D-0028 1 Hour Rated Assembly (Metal Decking) UL System No. HW-D-0208 1 Hour Rated Assembly
More information1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights
1 Exam Prep Application and Finishing of Gypsum Board GA-216-2016 Tabs and s These 1 Exam Prep Tabs are based on the Gypsum Association GA-216-2016 Application and Finishing of Gypsum Panel Products. Each
More informationRSIC-1-INSTALALTION GUIDE RSIC-1 SOUND ISOLATION CLIP
RSIC-1 Drywall Furring Channel: Minimum Requirements: 25 gauge, hemmed edge detail required on all 25 gauge furring channel. Meets or exceeds SFIA requirements. Depth: 7/8 inch Width Bottom: 2-9/16 to
More informationmcr Silboard self-supporting ventilation and smoke extraction ducts
mcr Silboard self-supporting ventilation and smoke extraction ducts INTENDED USE mcr Silboard is a calcium-silicate fireproof board designed for the construction of e.g. self-supporting fireproof general
More informationSystem No. HW-D-0548
System No. Ì73hwdÇ%P+11bÎ ANSI/UL2079 Assembly atings - 1 and 2 Hr (See Item 2) Maximum Joint Width - 3/4, 1 or 1-1/2 In. (See Item 3) Class II Movement Capabilities - 50 or 100 %Compression or Extension
More informationKINETICS NOISE CONTROL TEST REPORT #AT001073
KINETICS NOISE CONTROL TEST REPORT #AT001073 KINETICS NOISE CONTROL PRODUCTS: o ISOMAX CLIPS ACOUSTICAL RATINGS: o STC 63 TESTING AGENCY & REPORT NUMBER: o RIVERBANK ACOUSTICAL LABORATORIES o RAL TL06-048
More informationH R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to URBAN SURFACES. Series/Model: Urban Surfaces Soundtec
ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492 Rendered to URBAN SURFACES Series/Model: Urban Surfaces Soundtec Specimen Type: 152 mm Concrete Slab with Drop Ceiling Overall Size: 3048 mm
More informationSECTION GYPSUM BOARD
SECTION 092900 GYPSUM BOARD PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and General Provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationROCKWOOL FLEXI insulation. One product, many applications THE PERFECT FIT FOR: ROOFS DORMERS WALLS FLOORS.
THE PERFECT FIT FOR: ROOFS DORMERS WALLS FLOORS ROCKWOOL FLEXI insulation One product, many applications The perf Meets regulations Part L, Part E and Part B Fast and easy to install No cutting, no gaps,
More informationThe extra strong, extra durable, sound resistant system that you can direct fix to
C0 Partitions The extra strong, extra durable, sound resistant system that you can direct fix to All our systems are covered by SpecSure when using genuine Gyproc and Isover products gyproc.ie Utilising
More informationSECTION GYPSUM BOARD SYSTEM
PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 09 29 00 GYPSUM BOARD SYSTEM A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 specification sections,
More informationSECTION NON-STRUCTURAL METAL FRAMING
SECTION 09 22 16 PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories
More informationPROMATECT 50 Fire Resistant Steel Ducts
PROMATECT 50 Fire Resistant Steel Ducts PROMATECT 50 Cement Bound Matrix Board General Description PROMATECT 50 is Promat s newest matrix technology of binding organic materials and inorganic minerals
More informationImportant Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA
Important Notice In August 1, 2013, PABCO Gypsum, a division of PABCO building products, LLC acquired the QuietRock business and operations from Serious Energy, Inc. Serious Energy, Inc. corporate structure
More informationSECTION NON-LOAD BEARING WALL FRAMING. B. Section Furring and Lathing: Lath and furring for interior plaster applications.
SECTION 09.22.16 NON-LOAD BEARING WALL FRAMING PART 1 GENERAL 1.1 SECTION INCLUDES A. Non-load bearing metal studs for wall assemblies. B. Area Separation and shaft wall framing products. 1.2 RELATED SECTIONS
More informationrainspan installation guide horizontally laid panel
rainspan installation guide horizontally laid panel standard details A C 1. Check all support steelwork has been installed within standard dimensional tolerances. Check that the width of the steel bearing
More informationPart E robustdetails. robustdetails. January 2018 Update Pack
Part E Pack Dear Colleague, The first Update Pack of the year, and the first welcome from me as Chief Executive. Although new to the role, I have been with the company for nine years with responsibility
More informationSECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.
SECTION 06110 WOOD FRAMING PART 1 GENERAL 1.1 SUMMARY A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. B. Products Installed But Not Supplied
More informationWALL ASSEMBLIES. PHILLIPS MANUFACTURING CO. - Omaha, NE USA DESIGN NO. PMC/WA DESIGN NO. PMC/WA 60-01
WALL ASSEMBLIES PHILLIPS MANUFACTURING CO. - Omaha, NE USA DESIGN NO. PMC/WA 60-01 DESIGN NO. PMC/WA 60-01 1. Steel Framing Members (Floor, Sides, and Ceiling Runners)*: 'J'-shaped runner, minimum 2-1/2"
More informationLEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code
LEGACY REPORT Reissued January 1, 2000 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900 Montclair
More informationNATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction
Walls And Ceilings Single- And Double-Layer Construction 09 9 00/NGC Single-Layer Construction The single-layer construction system consists of a single layer of Gold Bond brand Gypsum Board applied to
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 092650 - GYPSUM BOARD SHAFT WALL ASSEMBLIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationFIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5
Design No. CEJ 27 P (HI/JS 20-05) Table. CONCRETE FLOOR ASSEMBLY: Max. two-hour rated concrete floor assembly made from either lightweight or normal weight concrete with a density of 00-50 pcf, with a
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 092216 - NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationLISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848
LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848 International Fireproof Technology Inc. 17528 Von Karman Avenue Irvine, CA 92614 This report is for the exclusive
More informationINTERTENANCY SYSTEMS 2018
KOROK INTERTENANCY SYSTEMS 2018 FOR TERRACED HOUSING AND APARTMENTS CBI 5113 FEB 2018 KOROK KOROK INTERTENANCY SYSTEMS 2018 FOR TERRACED HOUSING AND APARTMENTS SECURE, QUIET, FLEXIBLE. KOROK Intertenancy
More informationTHE RSIC SOUND ISOLATION CLIPS. RSIC-WFI (Wall Frame Isolator)
LOWEST LABOR COST HIGH PERFORMANCE WALL ISOLATION WOOD STEEL CONCRETE CMU CONDOS TIME SHARE / FRACTIONAL OWNERSHIP ASSISTED LIVING APARTMENTS HOTELS / MOTELS SINGLE FAMILY HOMES HOME THEATER COMMERCIAL
More informationSECTION GYPSUM BOARD SYSTEM
PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 09 29 00 GYPSUM BOARD SYSTEM A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 specification sections,
More informationProject No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6
DECEMBER, 2016 Page 1 of 6 1 GENERAL 1.01 RELATED SECTIONS.1 Section 01 33 00 - Submittal Procedures..2 Section 07 21 16 - Batt and Blanket Insulation..3 Section 07 92 10 - Sealants..4 Section 09 91 00
More informationrockspan installation guide horizontally laid panel
rockspan installation guide horizontally laid panel A 1. Check all support steelwork has been installed within standard dimensional tolerances. Check that the width of the steel bearing face is consistent
More informationKINETICS NOISE CONTROL TEST REPORT # AT001084
KINETICS NOISE CONTROL TEST REPORT # AT001084 KINETICS NOISE CONTROL PRODUCTS: o MODEL ISOGRID ACOUSTICAL RATINGS: o STC 63 o IIC 50 TESTING AGENCY & REPORT NUMBER: o NRC-CNRC o B-3463.6 KINETICS DRAWING
More informationSmarter. Safer. Leaner.
Smarter. Safer. Leaner. Fast Installation and Removal Decrease Leading Edge Exposure by 87% OSHA Compliant Versatile and Reusable Use Perimeter Protection Posts During Construction: At Building Perimeter
More informationrondo accessories CONTENTS:
rondo accessories SUMMARY Rondo has a range of accessories to complement our steel wall and ceiling systems, which includes Top Hats, Reveal Beads and Angles, as well as a rod bending tool for suspended
More information