FACE CFP - HORIZONTAL PANELS - OPTION 'B'
|
|
- Dwight Byrd
- 5 years ago
- Views:
Transcription
1 - Vertical Transitions 12F - H10.3 VHB TAPE 5.000" 127.0mm 5" FORMED TRANSITION STRIP w/ FLAT FACE CFP - - OPTION 'B' H10.3
2 CONCEALED FASTENED Panel Index 12F - H0 BASE DETAILS JOINT DETAIL PARAPET ROOF DETAIL INSIDE CORNER DETAIL OUTSIDE CORNER DETAIL SOFFIT DETAIL WINDOW JAMB DETAIL WINDOW HEAD DETAIL WINDOW SILL DETAIL REFERENCE SHEETS HO.1 - PANEL PROFILE INFORMATION HA.1 - WINDOW OPENING ISOMETRIC HA.2 - PENETRATION ISOMETRIC HB.1 - PANEL / PANEL OVERLAP SPLICE TRANSITION OPTIONS EACH DETAIL CONSISTS OF TWO DIFFERENT WALL CAVITY ASSEMBLIES; INSULATED AND NON-INSULATED. IE: DETAIL 1 ON THE ELEVATION WILL BE REPRESENTED BY TWO SHEETS 1.1 AND 1.2 ILLUSTRATING EACH RESPECTIVE WALL ASSEMBLY. WALL TYPE 1 & 2 WALL ASSEMBLY DISSEMINATES GENERAL, BEST PRACTICE, RECOMMENDATION FOR USE OF AIR / VAPOR S WITHIN U.S. DEPT. OF ENERGY CLIMATE ZONES
3 - WDW OPENING 12F - HA.1 TYPICAL WINDOW OPENING APPLICATION S NOT SHOWN FOR CLARITY FURRING OR GIRT "AS REQ'D" BY CODE METAL STUD EXTERIOR SHEATHING WATER RESISTIVE LOCALIZED FLEXIBLE MEMBRANE METAL FLASHING JAMB TRIM FOAM CLOSURE STRIP LOCALIZED FLEXIBLE MEMBRANE METAL STUD METAL SILL FLASHING LOCALIZED FLEXIBLE MEMBRANE WATER RESISTIVE HA.1
4 - PENETRATION 12F - HA.2 TYPICAL BEAM PENETRATION APPLICATION S NOT SHOWN FOR CLARITY DESIGN PROPER CLEARANCES TO ACCOMMODATE MOVEMENTS FURRING OR GIRT "AS REQ'D" BY CODE METAL STUD EXTERIOR SHEATHING LOCALIZED FLEXIBLE MEMBRANE JAMB TRIM w/ FOAM CLOSURE STRIP METAL FLASHING ATTACHMENT FLANGE STRUCTURAL MEMBER CLOSURE PLATE WET SEAL CUT OUT PERIMETER LOCALIZED FLEXIBLE MEMBRANE METAL STUD CFP - 12F EXTERIOR SHEATHING WATER RESISTIVE HA.2
5 - PANEL SPLICE TYPICAL PANEL / PANEL OVERLAP OTHER SPLICE OPTIONS AVAILABLE NOTE: WHEN LAPPING PANEL 'C' OVER 'A' THE TOP FASTENER FLANGE AND BOTTOM HOOK FEATURE MUST BE NOTCHED BACK TO CLEAR PANEL "A". ALIGNED JOINTS OR STAGGERED JOINTS ARE APPLICABLE. FURRING OR GIRT "AS REQ'D" BY CODE 12F - HB.1 WALL ASSEMBLY EXTERIOR SHEATHING WATER RESISTIVE UPPER PANEL NOTCH BACK OVERLAP PANEL TOP AND BOTTOM NON-CURRING BUTYL SEAL LOWER LEFT PANEL LOWER RIGHT PANEL 4" LAP MINIMUM HB.1
6 - PROFILE 12F - H0.1 INSTALL ITEM NUMBER: NET COVERAGE: 12" (1' 0") MAXIMUM LENGTH: (40 feet) MATERIAL OPTIONS COIL - COATED STEEL COIL - COATED ALUMINUM ANODIZED ALUMINUM FABRICATION OPTIONS STEEL: 18, 20, 22, 24 GAUGE ALUMINUM:.032" -.040" FINISH OPTIONS PAINTING "COIL COATED" HYLAR 5000 / KYNAR 500, MODIFIED POLYESTERS, AND OTHER CUSTOM OR EXOTIC FINISHES. ANODIZING CLEAR, BRONZES, AND VARIOUS OTHER COLORS COIL ANODIZED FOR COLOR CONSISTENCY. NOTES: 1. HEAVIER GAUGES MINIMIZE "OIL CANNING". 2. OIL CANNING IS NOT A CAUSE FOR REJECTION. 3. AN EXTENSIZE SELECTION OF ASSOCIATED PANEL FLASHING AND TRIMS ARE AVAILABLE. 4. CONTACT FSMP FOR UP TO DATE TECHINCAL INFORMATION AND MATERIAL LIMITATIONS. 5. ALL SYSTEMS WITH TESTING MUST BE INSTALLED IN ACCORDANCE WITH THE ASSEMBLY AS TESTED. H0.1
7 - Base Detail 12F - H1.1 CONTINUOUS 'Z' GIRT 1/8" x 1" CONT LOCALIZED MEMBRANE EXTERIOR SHEATHING BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) PRE FINISHED BASE FLASHING METAL FLASHING VAPOR "OPTIONAL" SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS PRECAST WEEP TUBE & BAFFLE CONCRETE IMPROVE ENERGY EFFICIENCY WITH PROPER COMPONENT WALL ASSEMBLIES IN MOST REGIONS, EXTERIOR WALLS HAVING INSIDE THE CAVITY SHOULD USE A VAPOR-PERMEABLE MEMBRANE APPLIED ON THE EXTERIOR SIDE OF THE WALL. A VAPOR-PERMEABLE MEMBRANE ALLOWS THE WALL CAVITY TO BREATH AND DRY POTENTIAL MOISTURE CAUSED FROM VAPOR PRESSURE. IN COLDER CLIMATES A NON-PERMEABLE VAPOR MUST BE INSTALLED ON THE INTERIOR SIDE OF THE WALL ASSEMBLY TO MINIMIZE OUTWARD VAPOR PRESSURE CAUSED BY HEATED AND HUMIDIFIED INTERIOR ENVIRONMENTS DURING THE COLD SEASON INTERNATIONAL BUILDING CODE WEATHER PROTECTION: EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A WEATHER-RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND CONSTRUCTED TO PREVENT THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A ON THE SIDE OF THE WALL BEHIND THE EXTERIOR VANEER. PROVIDE MEANS OF DRAINING WATER THAT ENTERS BETWEEN THE EXTERIOR VANEER AND THE WATER-RESISTANT. H1.1
8 WALL ASSEMBLY TYPE 2 - Base Detail 12F - H1.2 FACE OF PANE.500" MIN AIR SPACE 12.7 mm CONTINUOUS 'Z' GIRT 1/8" x 1" CONT BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) PRE FINISHED BASE FLASHING PRECAST WEEP TUBE & BAFFLE LOCALIZED MEMBRANE METAL FLASHING CONCRETE EXTERIOR SHEATHING VAPOR "OPTIONAL" SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS H1.2
9 - Seam Detail 12F - H2.1 EXTERIOR SHEATHING BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) CONTINUOUS HAT CHANNEL 1/8" x 1" CONT VAPOR "OPTIONAL" H2.1
10 WALL ASSEMBLY TYPE 2 - Seam Detail 12F - H2.2 1/8" x 1" CONT CONTINUOUS 'Z' GIRT BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) LOCALIZED MEMBRANE EXTERIOR SHEATHING VAPOR "OPTIONAL".500 MIN AIR SPACE 12.7 mm H2.2
11 - Seam Detail 12F - H2.3 EXTERIOR SHEATHING 1/8" x 1" CFP-UNA 25 HANGER CLIP BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) VAPOR "OPTIONAL" H2.3 HANGER CLIP OPTION
12 - Seam Detail 12F - H2.4 EXTERIOR SHEATHING 1/8" x 1" BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) VAPOR "OPTIONAL" H2.4 DIRECT FASTEN OPTION
13 - Parapet Roof Detail 12F - H3.1 PRE FINISHED COPING 'J' FLASHING 1/8" x 1" CONT LOCALIZED MEMBRANE ROOFING MEMBRANE WOOD BLOCKING SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS EXTERIOR SHEATHING FIRE RATED PLYWOOD VAPOR "OPTIONAL" H3.1
14 WALL ASSEMBLY TYPE 2 - Parapet Roof Detail 12F - H3.2 PRE FINISHED COPING 1/8" x 1" CONT LOCALIZED MEMBRANE 'J' FLASHING.500 MIN AIR SPACE 12.7 mm ROOFING MEMBRANE WOOD BLOCKING SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS EXTERIOR SHEATHING FIRE RATED PLYWOOD VAPOR "OPTIONAL" H3.2
15 - Inside Corner Detail 12F - H4.1 VAPOR "OPTIONAL" METAL CLAD FOAM CLOSURE URETHANE 1/8" x 1" 2.000" 50.8mm ATTACH TRIM BONDING TAPE PRE FINISHED INSIDE CORNER CONTINUOUS HAT CHANNEL INTERIOR DRYWALL EXTERIOR SHEATHING H4.1
16 WALL ASSEMBLY TYPE 2 - Inside Corner Detail 12F - H4.2 METAL CLAD FOAM CLOSURE URETHANE EXTERIOR SHEATHING 2.000" 50.8mm ATTACH TRIM BONDING TAPE (BY INSTALLER PRE FINISHED INSIDE CORNER CONTINUOUS 'Z' GIRT 1/8" x 1" CONT.500 MIN AIR SPACE 12.7 mm H4.2
17 - Inside Corner Option 12F - H4.5 FACTORY APPLIED CORNER ANGLE 1/8" x 1" FACTORY FABRICATED AND SEALED MITERED CORNER ASSEMBLY FORMED MITERED 90 INSIDE CORNER CFP - - OPTION 'C' H4.5
18 - Outside Corner Detail 12F - H5.1 EXTERIOR SHEATHING VAPOR "OPTIONAL" 1/8" x 1" CONTINUOUS HAT CHANNEL ATTACH TRIM W/BONDING TAPE PRE FINISHED OUTSIDE CORNER URETHANE 3.000" 76.2mm METAL CLAD FOAM CLOSURE H5.1
19 WALL ASSEMBLY TYPE 2 - Outside Corner Detail 12F - H MIN AIR SPACE 12.7 mm EXTERIOR SHEATHING VAPOR "OPTIONAL" ATTACH TRIM W/BONDING TAPE PRE FINISHED OUTSIDE CORNER 1/8" x 1" URETHANE CONTINUOUS 'Z' GIRT 3.000" 76.2mm METAL CLAD FOAM CLOSURE H5.2
20 - Outside Corner Option 12F - H5.5 FACTORY APPLIED CORNER ANGLE FACTORY FABRICATED AND SEALED MITERED CORNER ASSEMBLY 1/8" x 1" NON-CURRING FORMED MITERED 90 OUTSIDE CORNER CFP - - OPTION 'C' H5.5
21 - Soffit Detail 12F - H6.1 SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS VAPOR "OPTIONAL" 1/8" x 1" CONT 1/8" x 1" CONT BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) PRE FINISHED SOFFIT FLASHING 5.000" 127.0mm CONTINUOUS 'J' SHAPE EXTERIOR SHEATHING H6.1
22 WALL ASSEMBLY TYPE 2 - Soffit Detail 12F - H MIN AIR SPACE 12.7 mm VAPOR "OPTIONAL" SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS CONTINUOUS 'Z' GIRT 1/8" x 1" CONT BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) 5.000" 127.0mm PRE FINISHED SOFFIT FLASHING EXTERIOR SHEATHING H6.2
23 - Window Jamb Detail 12F - H7.1 VAPOR "OPTIONAL" EXTERIOR SHEATHING LOCALIZED MEMBRANE WINDOW/DOOR SYSTEM 1/8" x 1" PREFINISHED JAMB TRIM ATTACH TRIM W/BONDING TAPE 2.000" 50.8 mm CONTINUOUS HAT CHANNEL H7.1
24 WALL ASSEMBLY TYPE 2 - Window Jamb Detail 12F - H7.2 EXTERIOR SHEATHING VAPOR "OPTIONAL" LOCALIZED MEMBRANE WINDOW/DOOR SYSTEM PREFINISHED JAMB TRIM 1/8" x 1" CONTINUOUS 'Z' GIRT.500 MIN AIR SPACE 12.7 mm ATTACH TRIM W/BONDING TAPE 2.000" 50.8 mm H7.2
25 - Window Head Detail 12F - H8.1 EXTERIOR SHEATHING CONTINUOUS 'Z' SHAPE VAPOR "OPTIONAL" BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) PREFINISHED FLASHING WINDOW/DOOR SYSTEM SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS LOCALIZED MEMBRANE H8.1
26 WALL ASSEMBLY TYPE 2 - Window Head Detail 12F - H MIN AIR SPACE 12.7 mm EXTERIOR SHEATHING 1/8" x 1" CONT CONTINUOUS 'Z' GIRT VAPOR "OPTIONAL" BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) PREFINISHED FLASHING WINDOW/DOOR SYSTEM SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS LOCALIZED MEMBRANE H8.2
27 - Window Sill Detail 12F - H9.1 WINDOW/DOOR SYSTEM SILL TRM ATTACHMENT REVIT 1/8" x 1" CONT SILL TRIM CLIP (BY SILL TRIM INSTALLER) VAPOR "OPTIONAL" EXTERIOR SHEATHING H9.1
28 WALL ASSEMBLY TYPE 2 - Window Sill Detail 12F - H9.2 WINDOW/DOOR SYSTEM SILL TRM ATTACHMENT REVIT SILL TRIM CLIP (BY SILL TRIM INSTALLER) 1/8" x 1" CONT VAPOR "OPTIONAL" EXTERIOR SHEATHING.500 MIN AIR SPACE 12.7 mm H9.2
29 - Vertical Transitions 12F - H10.1 1/8" x 1" 4.00" MIN LAP NOTCH BACK FASTENING FLANGE AND HOOK FOR OVERLAP CLEARANCE OVERLAP SEAM JOINT CFP - - OPTION 'F' H10.1
30 - Vertical Transitions 12F - H10.2 URETHANE VHB TAPE 2.000" 50.8mm 1.000" 25.4mm 5.000" 127.0mm 2.000" 50.8mm 5" FORMED TRANSITION STRIP w/ REVEAL CFP - - STD. DETAIL 3.000" 76.2mm.563" 14.3mm 3" FORMED TRANSITION STRIP w/ SEAL JOINT CFP - - OPTION 'A' H10.2
12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS
CONCEALED FASTENED PANELS CFP-12 PANEL INDEX 12 - V0 BASE DETAILS HORIZONTAL JOINT DETAIL PARAPET ROOF DETAIL INSIDE CORNER DETAIL OUTSIDE CORNER DETAIL SOFFIT DETAIL WINDOW JAMB DETAIL WINDOW HEAD DETAIL
More informationMR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA
Existing Yard Security Light Proposed Rooftop Mechanical Screening (Slate Gray) Proposed 3 x4 x 4 x4 Windows Metal Awning Existing Doors Metal Siding(Slate Gray) Trim (Matte Black) 14 14 Proposed Addition
More informationELEVATION FOR DETAIL REFERENCE ONLY
6 7 8 10 OUTSIDE CORNER 19 20 4 5 11 21 22 15 16 13 12 OPENING 14 SOFFIT 18 END WALL 17 INSIDE CORNER 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CCV-01 CCV-02 CCV-03 CCV-04 CCV-05 CCV-06 CCV-07 CCV-08
More informationELEVATION FOR DETAIL REFERENCE ONLY
6 7 8 10 26 19 20 14 15 22 SOFFIT OUTSIDE CORNER INSIDE CORNER 23 25 24 25 5 27 28 29 16 11 OPENING 17 18 END WALL 21 12 13 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CSH-01 CSH-02 CSH-03 CSH-04 CSH-05
More informationELEVATION FOR DETAIL REFERENCE ONLY
8 4 5 6 9 16 10 15 11 SOFFIT 19 OUTSIDE CORNER 20 21 INSIDE CORNER 3 22 23 12 13 OPENING 14 END WALL 17 18 7 4 5 6 ELEVATION FOR DETAIL REFERENCE ONLY CSV-01 CSV-02 CSV-03 CSV-04 CSV-05 CSV-06 CSV-07 CSV-08
More informationELEVATION FOR DETAIL REFERENCE ONLY
5 6 8 9 1 10 15 SOFFIT OUTSIDE CORNER 16 18 19 12 OPENING 11 END WALL INSIDE CORNER 17 1 7 5 6 ELEVATION FOR DETAIL REFERENCE ONLY IWV-01 IWV-02 IWV-0 IWV-0 IWV-05 IWV-06 IWV-07 IWV-08 IWV-09 IWV-10 INDEX
More informationELEVATION FOR DETAIL REFERENCE ONLY
4 5 6 8 18 13 10 15 SOFFIT OUTSIDE CORNER INSIDE CORNER 16 17 3 19 20 11 9 OPENING 12 END WALL 14 7 4 5 6 ELEVATION FOR DETAIL REFERENCE ONLY EH-01 INDEX EH-02 STANDARD PANEL OFFERING EH-03 SIDE LAP DETAILS
More informationFACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET
KPH-DS-01-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV KPH-BS-04-MTLV KPH-OC-01-MTLV KPH-IC-01-MTLV KPH-SF-01-MTLV KPH-SF-02-MTLV
More informationPanel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing
EXTERIOR BASE DETAIL (FLUSH) EXTERIOR BASE DETAIL (OVERHANG) Base Trim with Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint Sealant Marriage Bead to Vertical Panel Joint Above and Below Z Flashing
More information1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights
1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights These 1 Exam Prep tabs are based on the 2012 Sheet Metal and Air Conditioning Contractors' National Association, Inc., seventh edition.
More informationAmeriplate. Rain Screen Wall System
Ameriplate Rain Screen Wall System Efficiency and fascinating free-floating effects are hallmarks of Metalwërks Ameriplate wall systems. With Ameriplate, the cut edges of the face plate material are the
More information7.0 - EXAMPLE DETAILS
7.0 - EXAMPLE DETAILS The drawings represented herein are believed to be accurate and conforming to current design and construction practices. However, the drawings should be used as a reference guide
More information900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900
CS-PJ-01-900 CS-DS-01-900 CS-PJ-02-900 CS-EL-01-900 CS-EL-02-900 CS-EL-03-900 CS-EL-04-900 CS-RD-01-900 CS-RD-02-900 CS-RD-03-900 CS-EV-01A-900 CS-EV-01B-900 CS-EV-02A-900 CS-EV-02B-900 CS-EV-03A-900 CS-EV-03B-900
More informationWeatherSmart Air Barrier Installation Guide
WeatherSmart Air Barrier Installation Guide 1 The intent of this document is to provide a guide for the installation of WeatherSmart as both a Weather Resistive Barrier (W.R.B.) and an Air Barrier Material
More informationKS SERIES - VERTICAL INSTALLATION
CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV
More informationENVELOPE The Ultimate In Performance In A Dry-Joint System RAINSCREEN (RS) SYSTEM TECHNICAL MANUAL
ENVELOPE 2000 RAINSCREEN (RS) SYSTEM The Ultimate In Performance In A Dry-Joint System TECHNICAL MANUAL System Assembly Substrate Layouts CAD Sections/Details Physical Properties Performance Properties
More informationELEVATION FOR DETAIL REFERENCE ONLY
#smr_elev 5b SEC 2 8i SEC 2 33 SEC 4 1a SEC 2 37 SEC 4 36 SEC 4 35 SEC 4 SOFFIT FRONT 6d SEC 2 7a SEC 2 SOFFIT REAR INSIDE CORNER (REAR) OUTSIDE CORNER (FRONT) 10a SEC 2 9b SEC 2 4e SEC 2 ELEVATION FOR
More informationSECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES
SECTION 07 4243 - PART 1 GENERAL 1.01 SECTION INCLUDES A. Composite wall panel system consisting of aluminum-faced composite panels in a rainscreen application as part of the assembly described below.
More informationIce Rink Renovation & New Clubhouse
SECTION 074243- METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationSUSPENSION REQUIREMENTS SEE DETAIL B1.2 TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET 2" MODULE. SPECIFICATIONS (unless noted otherwise)
1 5 32 " 2" 27 32 " REQUIRED FOR 1 1 4 " 113 32 " 2 21 32 " SEE DETAIL B1.2 CARRIER SPAN VARIES DEPENDING ON DESIGN WIND PRESSURE 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL B1.2 12
More informationArchitectural Wall Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is
More informationtypical section 1:50 Important:
00 Typical ventilated facade installation mounted with top hat channels onto external walls, awning soffit and fascia. 00 Wall panels are shown in varying heights, having open joints for ventilation of
More informationINSTALLING WATER-RESISTIVE BARRIERS & FLASHING
INSTALLING WATER-RESISTIVE BARRIERS & FLASHING IN A TWO-LAYER STUCCO APPLICATION Fortifiber Building Systems Group provides this guide to assist installers by demonstrating a two-layer installation of
More informationStudent Services & Classroom Addition
SECTION 074243 - METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationOmniplate Barrier Wall System
is an economical barrier wall system with visible caulk joints at all horizontal and vertical panel joints. As a barrier wall, serves as the primary weather barrier for the building envelope. It can be
More informationAmeriplate. Rain Screen Wall System
Ameriplate Rain Screen Wall System Efficiency and fascinating free-floating effects are hallmarks of Metalwërks Ameriplate wall systems. With Ameriplate, the cut edges of the face plate material are the
More informationSECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION.
SECTION 074213 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting
More informationENVELOPE The Ultimate In Performance In A Wet-Sealed System ROUT & RETURN (RR) SYSTEM TECHNICAL MANUAL
ENVELOPE 2000 ROUT & RETURN (RR) SYSTEM The Ultimate In Performance In A Wet-Sealed System TECHNICAL MANUAL System Assembly Substrate Layouts CAD Sections/Details Physical Properties Performance Properties
More informationArcwall. Rain Screen Wall System
Rain Screen Wall System is an economical drained and back-ventilated rain screen system for both walls and soffits manufactured from formed aluminum or stainless plate. The system combines excellent performance
More informationCENTRIA Concept Series Metal Wall Panels ZINC
CENTRIA Concept Series Metal Wall Panels ZINC CENTRIA Concept Series Metal Wall Panels are a versatile design choice for wall cladding panels. They are manufactured with a variety of profiles and five
More informationEMBRY RIDDLE PRESCOTT SECTION METAL COMPOSITE MATERIAL WALL PANELS
SECTION 074213.23 - WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationGAF EnergyGuard Polyiso Wall Sheathing
From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include:
More informationSiding and Soffit Installation Guidelines
Siding and Soffit Installation Guidelines email web phone 07 46 16 Longboard Siding & Soffit INTRODUCTION INSTALLATION GUIDELINES NOTE: These instructions are prepared for persons experienced in the field
More informationKARRIER PANEL - BRICK
KPH-DS-01-BRICK KPH-PJ-01-BRICK KPH-PJ-02-BRICK KPH-PJ-03-BRICK KPH-BS-01-BRICK KPH-BS-02-BRICK KPH-BS-03-BRICK KPH-OC-01-BRICK KPH-FO-01-BRICK KPH-FO-02-BRICK KPH-FO-03-BRICK KPH-FO-04-BRICK KPH-FO-05-BRICK
More informationTYPICAL ROOF CONDITION LAYOUT
FIXED POINTS TYPICAL ROOF CONDITION LAYOUT 15 17 9 16 29 12 14 11 3 7 35 20 6 23 30 31 24 13 18 Typical Roof Condition Layout... 1 Low Eave Isometric View - Fixed/ Floating... 2 Low Eave Section - Fixed/
More informationSiding and Soffit Installation Guidelines
Siding and Soffit Installation Guidelines email web phone 07 46 16 Longboard Siding & Soffit INTRODUCTION INSTALLATION GUIDELINES NOTE: These instructions are prepared for persons experienced in the field
More informationPrestige Series. (Horizontal Install.) Installation Guide
Prestige Series (Horizontal Install.) Installation Guide Prestige Series (Horizontal Install.) Installation Guide - Table of Contents - Section Page General Notes..............................................................
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 074213 - INSULATED METAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationCR# August 20, 2015
SECTION 07 40 00 - METAL ROOF AND WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Factory-formed and field-assembled, standing-seam metal roof panels. 2. Factory-formed and field-assembled,
More informationMetafor Panel System Installation Guide
Installation Guide innovative cladding design solutions Product Description Universal Flashing Kit Supplemental Guide for VM Pro-Zinc Training To enroll in a VM PRO-ZINC Training Course contact: UMICORE
More information4 " " SEE DETAIL B1.2. SPECIFICATIONS (unless noted otherwise)
REQUIRED FOR DETAIL 7 1 8 " 7 8 " SUSPENSION REQUIREMENTS SEE DETAIL B1.2 8" 7 1 1 8 " 4 " 2 1 8 " SEE DETAIL B1.2 CARRIER SPAN VARIES DEPENDING ON DESIGN WIND PRESSURE 12 GA HANGER WIRE, BY OTHERS, NOT
More informationArchitectural Roof Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification
More informationProper Installation of Insulated Metal Wall Panels
Proper Installation of Insulated Metal Wall Panels Insulated metal panels (IMPs) are an ideal cladding solution for pre-engineered metal buildings. They are available in lengths up to 50, and may also
More informationUltra Wall System. CAD Detail Sets
Ultra Wall System CAD Detail Sets Contents Page UWS-CM CAVITYMATE Ultra Contents 1-0 FOR: Details continuing on 1-1 thru 1-17 Cavity cut XPS board to fit between ladder tie masonry ties in CMU walls UWS-SL
More informationDIVISION 7: MOISTURE PROTECTION SECTION 07417: INSULATED METAL PANELS
DIVISION 7: MOISTURE PROTECTION SECTION 07417: INSULATED METAL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationBUILDING ENVELOPE DESIGN GUIDELINES APPENDIX 3
PART 1 GENERAL BUILDING ENVELOPE DESIGN GUIDELINES 1.01 INTRODUCTION A. This is a guideline on the Owner s minimum standards for: 1. Masonry Division 04 2. Copings Division 04 or 07 3. Cavity wall flashings
More informationThe better way to build TM. Installation Manual NAILBASE PANELS
The better way to build TM Installation Manual PANELS November 2018 SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................
More informationFirstEnergy Program Overview
FirstEnergy Program Overview Builder incentives $400 per unit + $0.10/kWh in projected savings Eligibility Located in service area of a FirstEnergy Utility Certificate of Occupancy Dates: FirstEnergy Ohio
More informationWrapShield SA Brick Tie Penetration
Brick Tie Penetration Outboard Vapor - Pemeable Insulation WrapShield SA Self-adhered WRB/AB field membrane Brick Tie must be Flush and compressed against Membrane with no prong penetrations Gasketed Fastener
More informationTW-12. (Horizontal Installation) Installation Guide
TW-12 (Horizontal Installation) Installation Guide TW-12 (Horizontal Install.) Installation Guide - Table of Contents - Section Page General Notes..............................................................
More informationCONTOUR CORRUGATED PANEL
CONTOUR CORRUGATED PANEL Table of Contents SECTION PAGE Designer Notes............................................... 1 Panel Net Coverage / Fasteners.................................... 2 ROOF Details
More informationFascia Systems. oofing 7.1
Systems oofing 7.1 TremLock TM A Pre-engineered, Non-Penetrating Metal Edge System oofing TremLock TM Pre-engineered, Non-penetrating Metal Edge System The TremLock is a pre-engineered, non-penetrating
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used
More informationAttachment of Exterior Wall Coverings Through Polyiso to Wood or Steel Wall Framing
Attachment of Exterior Wall Coverings Through Polyiso to Wood or Steel Wall Framing Installation Instructions Revised 10/25/2016 Scope For the 2015 IBC (cold-formed Steel) and IRC see ABTG Report No. 1503-02
More informationArchitectural Roof Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL WALL PANELS This Guide Specification
More informationDesign No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1
FIRESTOP JOINT SPRAY CFS-SP WB SILICONE JOINT SPRAY CFS-SP SIL F-RATING 2-HR. 2-HR. T-RATING -HR. -HR. APPLICATION THICKNESS PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table /8" WET FILM (/6"
More informationSECTION METAL COMPOSITE MATERIAL WALL PANELS
SECTION 074213.23 - METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationSpecifiers: Click on the icon in the WORD toolbar to reveal detailed instructions
Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying perforated
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 092216 - NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationArcwall. Rain Screen Wall System
Arcwall Rain Screen Wall System Arcwall is an economical drained and back-ventilated rain screen system for both walls and soffits manufactured from formed aluminum or stainless plate. The system combines
More informationProduct and System Specifications DuPont Flashing Systems
DuPont Building Innovations March 2007 4417 Lancaster Pike Chestnut Run Plaza 721 Wilmington, DE 19805 1-800-448-9835 www.construction.tyvek.com Product and System Specifications DuPont Flashing Systems
More informationSchedule A Development Permit No Issued this 18 day of April, 2018
Schedule A Development Permit No. 001610 Issued this 18 day of April, 2018 N No. Revision/Issue Date MM/DD/YY 1 ISSUED FOR TENDER 10/26/17 LEGEND: WORK AREA VILLAGE STROLL VILLAGE GREEN SOUTH WING 1 0
More information6" MAX CARRIER OVERHANG, TYP. MAX CARRIER SPACING VARIES DEPENDING ON DESIGN WIND PRESSURE, SEE DETAIL B1.2, TYP.
5 7 8 " NOM. 2" TYPICAL SYSTEM SECTION VERTICAL SUPPORT SPACING VARIES DEPENDING ON DESIGN WIND PRESSURE, SEE DETAIL B1.2, TYP. CARRIER SPLICE SEE DETAIL B1.4 6" MAX CARRIER OVERHANG, TYP. 1 12 GA HANGER
More informationARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM
RAINSCREEN (H&J) SYSTEM INSTALLATION DATA & DETAILS Omnis Panels, Inc. Architectural Building Panels 22 East Chicago Avenue Suite 210 Naperville, Illinois 60540 (800) 450-6099 (630) 355-4040 Fax: (630)
More informationARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM
RAINSCREEN (H&J) SYSTEM INSTALLATION DATA & DETAILS Omnis Panels, Inc. Architectural Building Panels 22 East Chicago Avenue Suite 210 Naperville, Illinois 60540 (800) 450-6099 (630) 355-4040 Fax: (630)
More informationCOMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INDEX INSTALLATION SEQUENCE INSTALLATION SEQUENCE INSTALLATION SEQUENCE
COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INSTALLATION SEQUENCE TT 5-8 TT- 13 INSTALLATION SEQUENCE INSTALLATION SEQUENCE TT- 4 TT-10 TT-14 TT-12 TT- 3 TT-11 TT-10 TT- 9 TT-11 TT- 2 INDEX (TT- 0): SYSTEM
More informationTremLock TM. Coping. A Pre-engineered Metal Coping System. oofing
oofing 7.3 A Pre-engineered Metal System oofing A Pre-engineered Metal System TremLock is a pre-engineered metal coping system designed with no exposed fasteners to accommodate movement. Basic Use: TremLock
More informationUniversity of Colorado Colorado Springs. National Cybersecurity Center Roof Replacement Package CSNA Project Number
ADDENDUM NUMBER 0 TO PROJECT MANUAL AND DRAWINGS August 9, 6 OWNER: ARCHITECT: University of Colorado Colorado Springs CSNA Architects PROJECT: National Cybersecurity Center Roof Replacement Package CSNA
More informationGuide Specification for the OSI QUAD Window and Door Flashing System
Henkel Corporation 26235 First Avenue Westlake, OH 1-866-591-2178 www.ositough.com Guide Specification for the OSI QUAD Window and Door Flashing System Specifier Note: The purpose of this guide specification
More informationNCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology FLASHING DETAILS FOR CONCRETE MASONRY WALLS TEK 19-5A Water Penetration Resistance
More informationStone and Masonry Veneer
Stone and Masonry Veneer R703.7 Stone and masonry veneer, general. Stone and masonry veneer shall be installed in accordance with this chapter, Table R703.4 and Figure R703.7. These veneers installed over
More information200 / 300 SERIES PANELS COLD STORAGE
CS-DS-01-200/300 DISCLAIMER CS-CD-01-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CS-CD-02-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CONTINUED CI-PP-01-200 PANEL PROFILES 200 SERIES
More informationPebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details
Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier Typical Details (THIS PAGE INTENTIONALLY LEFT BLANK Pebbletex Wall System Class PB Exterior Insulation
More informationPella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...
SECTION DIRECTORY General Information Introduction... V250-ID-886 Installation Accessories and Applications... V250-ID-886 Typical Sealant Placement Details... V250-ID-887 Fin Installation Details Wood
More informationPRE-ENGINEERED METAL BUILDING SYSTEM
PRE-ENGINEERED METAL BUILDING SYSTEM PART 1 GENERAL 1.1 SUMMARY A. The building shall include all primary and secondary structural framing members, connection bolts, roof and wall covering, flashing, gutter,
More informationPrestige Series 12. Installation guide
Prestige Series 12 Installation guide PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS Section Page Notes to Designer/User.................... 2 Panel Options............................. 3 Panel Details..............................
More informationExterior Stucco and Siding Installation
Exterior Stucco and Siding Installation CITY OF NEWARK, CALIFORNIA BUILDING INSPECTION DIVISION 37101 Newark Boulevard, Newark, CA 94560-3796 510-578-4261 Fax 510-578-4307 e-mail: building.inspection@newark.org
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used
More informationWall Assembly - ACM Metal Panel at Steel Stud Framing SCALE: 3" = 1'-0"
Thermafiber "RainBarrier 45" Nvelope "NH2" Bracket Adapter Nvelope Wall Bracket (90mm or as Req'd) ACM Metal Panel System Metal Panel Extrusion per ACM Manufactuer 1 2 " Self-Drilling Stainless Steel Fastener
More informationHenri Fennell, CSI/CDT ABX 2015
Henri Fennell, CSI/CDT ABX 2015 Henri is an architect and building envelope specialist with over forty years of experience in the construction industry. He was a pioneer in the solar industry, introduced
More informationDIVISION 7 THERMAL AND MOISTURE PROTECTION
DIVISION 7 THERMAL AND MOISTURE PROTECTION UCSC Campus Standards Handbook Waterproofing Standards 07100 1 SECTION 07100: WATERPROOFING STANDARDS A. Guarantee 1. Provide a guarantee on Contractor's letterhead
More informationNational Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 Section [ ].
National Master Specification (NMS) Section 07 21 16 BLANKET INSULATION Publisher: Spex.ca Page 1 Approved: 2014-12-31 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section [ ]. 1.2 REFERENCES.1 CSA Group.1
More informationEclipse Energy Guard. Product Information & Installation Manual General Installation Requirements
Product Information & Installation Manual 01 Important Notice to Buyers and Users of RoyOMartin wall system These instructions are not intended to cover every installation requirement, application, detail
More information[Project Name] Section [ ]
Page 1 PART 1 - GENERAL 1.1 SECTION INCLUDES 1.1.1 Design, labor, products, equipment and services necessary for interior/exterior Aluminum Facade System (AFS) work, in accordance with the Contract Documents.
More informationOCS ONE COAT STUCCO A custom blend of Portland cement, sand, extenders, fiber reinforcement and modifiers.
OCS ONE COAT STUCCO A custom blend of Portland cement, sand, extenders, fiber reinforcement and modifiers. Designed to save material by functioning as an exterior cladding in thicknesses ranging from 3/8
More informationContainer Installation Guide
Continuous Insulation Container Installation Guide Panels and InSerts The InSoFast CX Container panel and the InSerts are designed to fit most shipping containers. Containers have three types of corrugations:
More information138 H-STUD AREA SEPARATION WALL SYSTEM
H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic fashion by the results of this actual townhouse fire in which the two-hour fire-rated
More informationDuPont Tyvek Wall Underlay Install Guide
DuPont Tyvek Wall Underlay Install Guide (For Residential & Light Commercial Buildings) Acceptable Solution to NZBC E2/AS1 New Zealand As at 1/4/15 Version 2 Subject to change without notice DuPont Tyvek
More informationDist. by: BEST MATERIALS Ph:
Dist. by: BEST MATERIALS Ph: 800-474-7570 www.bestmaterials.com Email: Sales@BestMaterials.com FLASHING SYSTEM ENGINEERED PRODUCT SYSTEMS PRODUCT BROCHURE Distributed by: BEST MATERIALS Distributed by:
More informationC. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope.
SECTION 08 4519 - POLYCARBONATE WALL SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. Exterior System: The design, manufacture and installation of an aluminum and polycarbonate insulating translucent system.
More informationARCHITECTURAL DESIGN GUIDE
HPCI BARRIER TM INSULATED METAL PANEL ARCHITECTURAL DESIGN GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY PIONEERING INSULATED METAL PANEL TECHNOLOGY TABLE OF CONTENTS INTRODUCTION...6 RAINSCREEN WALL
More informationWHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED.
WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED. Build walls and ceilings with a strong base, sturdy reinforcements and much more with Phillips extensive line of high quality products. As a single source
More informationDIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING
DIVISION 5 METALS SECTION 05 40 00 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationCENTRIA FORMABOND II Metal Composite Wall System
CENTRIA FORMABOND II Metal Composite Wall System CENTRIA FormaBond II is the only true metal composite panel wall system designed, manufactured and fabricated by a single, reliable national manufacturer
More information