1 Solutions for California Title 24
2 Title 24 Envelope Highlights Envelope Highlights Mandatory Measures There are several new thresholds for mandatory envelope requirements including: Ceiling/Roof insulation maximum = U-factor (R- 22 wood framing) Prescriptive High Performance Walls In Climate Zones 1-5 & 8-16, above grade framed wall assemblies must not exceed a maximum U-factor of 0.051: 16 OC framing R19 cavity + R5 continuous 16 OC framing R15 cavity + R8 continuous In Climate Zones 6 & 7, the maximum U-Factor is Prescriptive High Performance Attics There are three options that may be used to comply: Option A: Ducts and air handler may be located in the attic Install attic radiant barrier (Zones 2-15) Install R-38 insulation at ceiling (R-30 in zones 3 & 5-7) Install continuous roof deck insulation (Zones 4 & 8-16) R-6 with air space above insulation/ R-8 with no space
3 Rmax Solutions A complete line of insulation solutions To help meet Title 24 requirements.
4 Continuous Insulation for Roofs Rmax Nail Base Products Meet CA 2016 Title 24 Roof Insulation Requirements Option A Continuous Insulation Above Roof Rafters No Air Space (R8) or With Air Space (R6)
5 Vented Nailable Base w/ T24 Chart Composite Panel 7/16 OSB, Vent Space, Polyiso Foam Insulation 1, 1.5 or 2 vent space based on length of run On-line calculators such as Net free area per linear foot TABLE A COMPONENT PACKAGE-A STANDARD BUILDING DESIGN Title 24 Climate Zone Building Envelope Insulation: Roofs/Ceilings Option A Continuous Insulation Above Roof Rafter Roof Type No Air Space With Air Space NR NR NR R8 NR NR NR R8 R8 R8 R8 R8 R8 R8 R8 R8 NR NR NR R6 NR NR NR R6 R6 R6 R6 R6 R6 R6 R6 R6
6 Insulated Roof Deck (half SIPS) Rmax Thermasheath-RDeck Foil faced polyiso laminated to 7/16 OSB *PATENT PENDING* All-In-One Cool Attic Solution Nailable Surface Roof Diaphragm Continuous Insulation Interior Radiant Barrier Finish Meet CA 2016 Title 24 Roof Insulation Requirements Option A Continuous Insulation Above Roof Rafters No Air Space (R8) or With Air Space (R6)
7 RDeck Installation Nail Board Fasteners Engineering Document Sealed by PE SDPWS, Section 4.2 Tables Nominal unit shear capacities for blocked and unblocked diaphragms Fastener capacity tables
8 Continuous Insulation for Walls Half- SIPS insulated wall panel- ThermaBase-CI
9 ThermaBase-CI Fastening Chart for ThermaBase
10 4-in-1 Approach: One Building Product to Complete the Envelope 1 Structural Bracing Install continuously across the wall to simplify design Install as a braced wall panel with Thermasheath-3 to optimize design costs Eliminates the need for heavy OSB sheathing Decrease time and costs associated with materials and labor R-SEAL Construction Tape 2 Continuous Insulation (c.i.) Polyiso has the highest R/inch of any foam plastic insulation Eliminates thermal bridging Allows you to meet or exceed energy code requirements Lowers energy consumption and energy bills Air Barrier Prevent air infiltration Keeps the home comfortable Makes your HVAC systems run more efficient Water Barrier Eliminates the need for house wrap or felt Resists water intrusion and moisture migration Defends against the growth of mold and mildew
11 Recommended Zones Wind Zones: Use prescriptively in wind zones 110 mph Use in higher wind zones requires an engineered design Seismic Zones: Use prescriptively in seismic design categories/regions A, B and C D o, D 1 and D 2 Installation Step 1: Measuring and Cutting Wind Loading Seismic Loading NOTE: With ½ gypsum applied to interior. Adjustment factor needed when there is no interior gypsum. Refer to TER for full details.
12 Recommended Usage Residential applications with numerous veneers: brick, stone, stucco, siding (wood, vinyl, aluminum), cement board, etc. Exterior wood frame walls Use as intermittent bracing with Thermasheath-3 Use as continuous structural insulated sheathing With taped joints and other standard construction practices for sealing, achieve air barrier and water-resistive barrier (WRB)
13 Installation - Step 1: Measuring and Cutting Do NOT install panels unless temperature is above 20 F Wear eye protection when using power cutting tools Safety mask may be necessary while cutting this product due to nuisance dust Measure and mark panels for cutting using: Chalk line Straight edge and marker Cut boards on a level, durable surface, using a circular saw Notes for cutting: Do not shave, rasp or carve facers off any panels Rmax does not recommend scoring or cutting the back side of a panel allowing the board to conform to framing regulations Rmax does not recommend the cutting or trimming of panels with the score and snap method Polyiso will not break cleanly or evenly recommend using a sharp, fine-toothed saw
14 Installation - Step 2: Installing Panels The Rmax logo must face out Install panels vertically with the length dimension of the panels parallel to the framing behind Install directly over studs, refer to TER No for framing requirements Note: All perimeter edges must be backed and fastened to a framing member.
15 Installation - Step 2: Installing Panels (continued) Use Thermasheath-SI continuously OR Use Thermasheath-SI in areas where bracing is required per code Integrate remaining wall with Rmax Thermasheath-3 insulation R-SEAL Construction Tape
16 Installation - Step 3: Fastening Fasten boards using approved staples every 3 along perimeter and every 6 in the fields of the boards Fasteners must be placed not less than 3/8 (9.5 mm) from sheathing edges Staples shall be a minimum 16 gauge, 1/2 or 1 crown, at least 1 1/4 leg and penetrate a minimum of 1 into the stud Nails shall be minimum x 2 3/8 and penetrate a minimum of 1 ¼ inch into the stud. Sheathing joints must be butted at framing members and a single row of fasteners must be applied to each panel edge into the stud behind Note: Maintain a minimum 1 penetration into wood studs, fasteners may be countersunk. FASTEN EVERY 3 ALONG PERIMETER FASTEN EVERY 6 IN THE FIELD DO NOT TACK FASTEN COMPLETELY FIRST NOTE: Do not tack sheathing products to framing, but fasten each panel completely once fastening begins.
17 Installation - Step 4: Taping To achieve a WRB: Tape all joints & protrusions with 3 R-SEAL Construction Tape Center the tape over the joints to cover fastener penetrations Tape must be installed in temperatures between -25 F to 135 F Apply in shingle like fashion starting from bottom up NOTE: Fasteners in the field of the board do not need to be taped to achieve WRB.
18 Solutions for California Title 24
Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY
Insulation for the Building Envelope ROOF WALL SPECIALTY PRODUCT DESCRIPTION Rmax Thermasheath-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam
More informationGAF EnergyGuard Polyiso Wall Sheathing
From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include:
More informationThermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY
Insulation for the Building Envelope ROOF WALL SPECIALTY PRODUCT DESCRIPTION Rmax Thermasheath-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam
More informationThermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY
Insulation for the Building Envelope ROOF WALL SPECIALTY PRODUCT DESCRIPTION Rmax Thermasheath-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam
More informationR-Matte Plus-3: Insulation for the Building Envelope
Attic and Crawl Space Applications R-Matte Plus-3 may be applied to the interior face of stud walls or roof rafters within attics and crawl spaces to provide a layer of continuous insulation (ci). Simply
More informationGold Bond BRAND Gypsum Sheathing
BRAND 09 06 29 16 00/NGC 43/NGC brand is a moisture-resistant sheathing installed on the outside of exterior framing as a substrate for exterior claddings. It is manufactured with a treated water-resistant
More informationThermasheath-XP. Insulation for Exposed Use
Insulation for Exposed Use PRODUCT DESCRIPTION Rmax Thermasheath-XP is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (Polyiso) foam bonded to durable, embossed
More informationAttachment of Exterior Wall Coverings Through Polyiso to Wood or Steel Wall Framing
Attachment of Exterior Wall Coverings Through Polyiso to Wood or Steel Wall Framing Installation Instructions Revised 10/25/2016 Scope For the 2015 IBC (cold-formed Steel) and IRC see ABTG Report No. 1503-02
More informationFraming Methods Structural Components
Framing Methods Structural Components Balloon Framing *Balloon framing or Eastern framing the exterior studs run from the top of the foundation to the top of the highest level. Benefits of this type of
More informationPrescriptive Wind Pressure Performance of Foam Plastic Insulation Used as Insulating Sheathing in Exterior Wall Covering Assemblies. TER No.
Prescriptive Wind Pressure Performance of Foam Plastic Insulation Used as Insulating Sheathing in Exterior Wall Covering Assemblies TER No. 1006-01 Foam Sheathing Committee (FSC) Members Atlas Roofing
More informationWeatherSmart Air Barrier Installation Guide
WeatherSmart Air Barrier Installation Guide 1 The intent of this document is to provide a guide for the installation of WeatherSmart as both a Weather Resistive Barrier (W.R.B.) and an Air Barrier Material
More informationHigh Performance Walls:
High Performance Walls: Advanced Framing Walls Systems and Insulated Headers Karyn Beebe, PE, LEED AP APA The Engineered Wood Association Quality Services Division Technical Services Division Field Services
More informationHigh Performance Walls:
High Performance Walls: Advanced Framing Walls Systems and Insulated Headers Karyn Beebe, PE, LEED AP APA The Engineered Wood Association Quality Services Division Technical Services Division Field Services
More informationGA APPLICATION OF GYPSUM SHEATHING
1. Scope 1.1 This specification describes the minimum requirements for, and the methods of handling, storage, and application of, gypsum sheathing for use as a substrate for exterior claddings. 1.1.1 Exterior
More informationTSX Insulation for Exposed Use ROOF WALL SPECIALTY
TSX-850 Insulation for Exposed Use ROOF WALL SPECIALTY PRODUCT DESCRIPTION Rmax TSX-850 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (Polyiso) foam core bonded
More informationInstallation Guidelines
Installation Guidelines The Vertibreak Wall System: Installation Guidelines Rainscreen Insulation for New or Retrofit Construction Applications Vertibreak rainscreen insulation is an expanded polystyrene
More informationDuPont RainVent Batten Installation Guidelines
DuPont RainVent Batten Installation Guidelines Purpose: To improve the ventilation and draining space behind a cladding system or 3-coat stucco system in residential construction. The DuPont RainVent Batten
More informationTSX Insulation for Exposed Use ROOF WALL SPECIALTY
Insulation for Exposed Use ROOF WALL SPECIALTY PRODUCT DESCRIPTION Rmax TSX-8500 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (Polyiso) foam core bonded to
More informationINSTALLING WATER-RESISTIVE BARRIERS & FLASHING
INSTALLING WATER-RESISTIVE BARRIERS & FLASHING IN A TWO-LAYER STUCCO APPLICATION Fortifiber Building Systems Group provides this guide to assist installers by demonstrating a two-layer installation of
More informationCalifornia Building Envelope Solutions
California Building Envelope Solutions Attics & Walls October 2017 What s New in 2016 Title 24 Attics High Performance Attic New prescriptive requirements Roof deck insulation in many CZs Walls High Performance
More informationContents. ZIP System R-Sheathing
ZIP System R-Sheathing 2 Contents 02 ZIP System R-Sheathing General Notes, Guidelines and Limitations 03 ZIP System R-Sheathing Installation 05 Structural Bracing to Resist Lateral Forces 06 ZIP System
More informationJRS ENGINEERING. Continuous Insulation Overall Effective. Presented by: Marty Deemter, P.Eng. Scott Croasdale, M.Eng, P.Eng, PE
JRS ENGINEERING Building Envelope Consultants Continuous Insulation Overall Effective R-Value of Exterior Walls Presented by: Marty Deemter, P.Eng. Developed by: Scott Croasdale, M.Eng, P.Eng, PE Topics
More informationEPA Seal and Insulate with ENERGY STAR Insulation Product Certification Report: GAF EnergyGuard Polyiso Insulated Sheathing Board Insulation
UL LLC 333 Pfingsten Road Northbrook, IL 60062 2017-6-05 U.S. Environmental Protection Agency (EPA) Seal and Insulate with ENERGY STAR Insulation Product Certification Report Type EnergyGuard Polyiso Insulated
More informationfor New Construction Applications
INSTALLATION GUIDE for New Construction Applications Designing and building instructions for ThermalStar LCi are described in the following manual. General installation, fastening details and instructions
More informationENCLOSURE: SIMPLE LAYERS
ENCLOSURE: SIMPLE LAYERS THE BEST RESIDENTIAL WALL ASSEMBLY Brick Face/ cavity/ impermeable membrane as drainage plane Impermeable foam as insulation 1 Moisture Movement through Air Leakage vs. Diffusion
More informationThe better way to build TM. Installation Manual NAILBASE PANELS
The better way to build TM Installation Manual PANELS November 2018 SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................
More informationOriginally Issued: 11/04/2016 Revised: 11/28/2017 Valid Through: 11/30/2018
HUBER ENGINEERED WOODS ZIP SYSTEM R-SHEATHING CSI Section: 06 12 00 Structural Panels 06 16 00 Sheathing 1.0 RECOGNITION ZIP System R-Sheathing panels, manufactured by Huber Engineered Woods, LLC, were
More informationREPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3089 Reissued 07/2016 This report is subject to renewal 07/2018. DIVISION: 07 00
More informationAirspace R-Values. Educational Overview. Revised 12/6/2016
Airspace R-Values Educational Overview Revised 12/6/2016 Introduction Airspaces contained within building envelope assemblies are known to contribute to thermal performance. But, the actual R-value for
More informationAdministrative Changes
Revised 11/29/06 Knox County Residential Building Codes Significant Changes From The 1995 CABO One And Two Family Dwelling Code To The 2006 International Residential Code All one and two family dwellings
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: GENTEK BUILDING PRODUCTS, INC.
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (00) 423-657 (562) 699-0543 www.icc-es.org ESR-1133 Reissued 11/2017 This report is subject to renewal 11/201. DIVISION: 07 00 00
More informationHigh Performance Walls:
High Performance Walls: Advanced Framing Walls Systems and Insulated Headers Karyn Beebe, PE, LEED AP 2016 Title 24 High Performance Walls Proposed U-factor = 0.05 Continuous Insulation Staggered Stud
More informationNOVAWRAP ASPIRE Q & A
TM NOVAWRAP ASPIRE i build with What is building wrap and why should I use NovaWrap Aspire? A building wrap like NovaWrap Aspire is a critical element in the building envelope system which is the physical
More informationInsulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS
Insulation First Revison October 2016 DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS 1. General Information This Guide describes the use of Kingspan GreenGuard DC14 Drainage
More informationSI-Strong Structural Insulation STYROFOAM SIS, SIS Plus Canada Limit States Design. TER No
SI-Strong Structural Insulation SIS, SIS Plus Canada Limit States Design TER No. 1808-04 Ox Engineered Products, LLC 22260 Haggerty Road #365 1255 N. 5th St. Northville, MI 48167 Charleston, IL 61920 989-798-5923
More informationINSULATION BATT (1) (2) Code Reference: 2016 Title 24, Reference Appendices RA3.5. Pressure or Friction Fit
R-H-DI1 Envelope INSULATION BATT Pressure or Friction Fit Insulation should be cut to fit snugly against studs on all sides, and should completely fill the cavity with no air gaps. Cut lengths of insulation
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1504 Reissued 03/2017 This report is subject to renewal 03/2018. DIVISION: 07 00
More informationTrusted ICC ES APA TH STREET. Conformity! subject of the
0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 42 687 (62) 699 04 www.icc es.orgg ESR 286 Reissued 07/207 This report is subject to renewal 07/209. DIVISION: 06 00 00 WOOD, PLASTICS
More information2006 INTERNATIONAL ENERGY CONSERVATION CODE
2006 INTERNATIONAL ENERGY CONSERVATION CODE DOCUMENTATION Code Change No: EC28-06/07 Original Proposal Sections: IECC: 202, 402.5, 402.5.1 (New), Table 402.5.1 (New), 402.5.2 (New), 402.5.3 (New), 402.2.8,
More informationU.S. EDITION RESIDENTIAL CONSTRUCTION DETAILS SAMPLE. A visual guide to construction detailing. Emma Walshaw
RESIDENTIAL CONSTRUCTION DETAILS U.S. EDITION A visual guide to construction detailing Emma Walshaw Contents INTRODUCTION 4 PRINCIPLES OF CONSTRUCTION DETAILING 6 FOUNDATIONS 9 PRINCIPLES OF FOUNDATION
More informationapplication instructions
application instructions FOUNDATIONS 76 & 120 SERIES PRIMED PANEL SIDING ARCHITECTURAL COLLECTION REVERSE BOARD & BATTEN AND STUCCO PANEL SIDING General At the time of manufacture, siding meets or exceeds
More informationIntegrated Air & Water Barrier Systems
Integrated Air & Water Barrier Systems Presented by [ Jeff Presenter s Key, Georgia-Pacific Name ] Wood Products AIA Course: GP-FF-WRBAB Credit Designation: LU HSW Please add relevant logo here Disclaimer:
More informationThermo-Ply Red & Thermo-Ply Red AMG Structural Sheathing Canada Limit States Design. TER No
Structural Sheathing Canada Limit States Design TER No. 1808-03 Ox Engineered Products, LLC 22260 Haggerty Road #365 700 Centreville Rd Northville, MI 48167 Constantine, MI 49042 989-798-5923 269-435-2425
More informationMay 2013 CONSTRUCTION MANUAL
May 2013 CONSTRUCTION MANUAL Table of Contents Limitations... 1 Panel Specification... 2 Facing Material (OSB)... 2 Adhesive Material... 2 Core Material... 2 Panel Weight... 3 Panel Insulation... 3 Panel
More informationFigures 1A-1C Light frame and mass wall systems with continuous insulation for codecompliant. commercial building construction.
INTRODUCTION National model energy codes are advancing the way in which we approach building commercial and residential exterior walls by emphasizing the use of continuous insulation (CI) systems, which
More informationWE International, Inc.
M E E T Y O U R R O U N D T H E Steel Frame Building Roof Application - Drape Method Ideal insulation for steel frame building application Quick and easy to install Provides reflective insulation for radiant
More informationVersetta Stone Panelized Stone Veneer Applications Over Continuous Insulation. TER No Boral Stone Products LLC
Applications Over Continuous Insulation TER No. 1212-01 Boral Stone Products LLC 200 Mansell Court East, Suite 310 Roswell, GA 30076 419-318-5345 949-341-8890 (fax) chris.hines@boral.com versettastone.com
More informationCity of Long Beach Department of Development Services Building and Safety Bureau. Design Limitation for Wood Shear Walls
Department of Development Services Building and Safety Bureau Design Limitation for Wood Shear Walls Information Bulletin BU-004 Eff: 01-01-2008 Rev: 09-29-2011 The purpose of this Informational Bulletin
More informationINSTALLATION GUIDE Structural insulated sheathing, all in ONE panel!
One INSTALLATION GUIDE Structural insulated sheathing, all in ONE panel! One Designing and building instructions for ThermalStar One are described in the following manual. These instructions can be considered
More informationManaging Condensation and Thermal Performance with Continuous Insulation
Managing Condensation and Thermal Performance with Continuous Insulation Presented by Brian Shores, Don Simon Disclaimer: This presentation was developed by a third party and is not funded by WoodWorks
More information1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights
1 Exam Prep Application and Finishing of Gypsum Board GA-216-2013 Tabs and s These 1 Exam Prep Tabs are based on the Gypsum Association GA-216-2013 Application and Finishing of Gypsum Panel Products. Each
More informationGarage/Accessory Structures
Garage/Accessory Structures City of New Prague Building Inspections Department 118 Central Ave N New Prague, MN 56071 (952) 758-4401 Fax (952) 758-1149 Requirements for submitted Building Plans Signed
More informationDuPont Tyvek Wall Underlay Install Guide
DuPont Tyvek Wall Underlay Install Guide (For Residential & Light Commercial Buildings) Acceptable Solution to NZBC E2/AS1 New Zealand As at 1/4/15 Version 2 Subject to change without notice DuPont Tyvek
More information9.36. Energy Efficiency
Resources and Information NRCAN Energy Efficiency http://www.nrcan.gc.ca/energy/efficiency Canadian Wood Council Wall Thermal Design Tool http://cwc.ca/resources/wall-thermal-design/ 9.36. Energy Efficiency
More information1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights
1 Exam Prep Application and Finishing of Gypsum Board GA-216-2016 Tabs and s These 1 Exam Prep Tabs are based on the Gypsum Association GA-216-2016 Application and Finishing of Gypsum Panel Products. Each
More informationHeel Blocking Requirements and Capacity Analysis. Overview Revised 3/22/2017
Heel Blocking Requirements and Capacity Analysis Overview Revised 3/22/2017 SBCA has been the voice of the structural building components industry since 1983, providing educational programs and technical
More informationBuilding Envelope
9.36.2. Building Envelope Module 2 BCBC 9.36. 2014 1 Richard Kadulski Architect 9.36.2. Building Envelope Focus is on total building performance, not just thermal insulation Heat transfer and air leakage
More informationHouseWrap Applications System R-Value: R-4.17 Horizontal Heat Flow Only
Installation Method (Existing Walls) 1. ESP Low-E Housewrap is installed over exterior wall sheathing, make sure reflective side faces out: foil flange faces down. 2. Determine width of ESP Low-E HouseWrap
More informationTER No Attachment of Exterior Wall Coverings Through Kingspan GreenGuard Extruded Polystyrene (XPS) Sheathing to Wood or Steel Wall Framing
Attachment of Exterior Wall Coverings Through Kingspan Insulation LLC 2100 RiverEdge Parkway Suite 175 Atlanta, GA 30328 kingspaninsulation.us TER No. 1410-09 Issue Date: January 30, 2015 Updated: March
More informationINSTALLATION MANUAL. ZIP System R12 Sheathing. Contents. 07 ZIP System R12 Sheathing Window Installation 08 ZIP System R12 Sheathing Siding Guidelines
ZIP System R12 Sheathing INSTALLATION MANUAL Contents 02 ZIP System R12 Sheathing General Notes, Guidelines and Limitations 03 ZIP System R12 Sheathing Installation 05 ZIP System R12 Sheathing Non Structural
More informationHigh Performance Walls: How Stucco and Continuous Insulation Work. Nick Brown VP, SMA Ex-President, Merlex Stucco President, Build Smart Group
High Performance Walls: How Stucco and Continuous Insulation Work Nick Brown VP, SMA Ex-President, Merlex Stucco President, Build Smart Group Defining Stucco Terms Standard 3-coat stucco 7/8 thick R-0.2
More informationTER No Attachment of Exterior Wall Coverings Through Kingspan Kooltherm Insulation Boards to Wood or Steel Wall Framing
Attachment of Exterior Wall Coverings Through Kingspan Kooltherm Insulation Boards to Wood or Wall Framing Kingspan Insulation LLC 2100 RiverEdge Parkway Suite 175 Atlanta, GA 30328 kingspaninsulation.us
More informationLP OSB Sheathing & Structural 1 Sheathing
Rated OSB Sheathing Roof Panels Span Ratings Max. Live Load Thickness Span Rating for Roofs (lbs)** 3/8" 24/0 30 7/16" 24/16 40 15/32" 32/16 70 1/2" 32/16 70 19/32" 40/20 130 23/32" 48/24 175 1-1/8" 48
More informationHP+ Building Enclosure Systems. Affordable Solutions for Title 24 and Beyond
HP+ Building Enclosure Systems Affordable Solutions for Title 24 and Beyond BASF High Performance Envelope Solutions Reduce moisture risk Improve Title 24 compliance margin Save materials and labor on
More informationTER No Attachment of Exterior Wall Coverings Through Kingspan GreenGuard Extruded Polystyrene (XPS) Sheathing to Wood or Steel Wall Framing
Attachment of Exterior Wall Coverings Through Kingspan Insulation LLC 2100 RiverEdge Parkway Suite 175 Atlanta, GA 30328 kingspaninsulation.us TER No. 1410-09 Issue Date: January 30, 2015 Updated: August
More informationCarroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage
Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage The following list of code requirements is intended to assist you in complying with the Code of Public
More informationGeneral. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings
application instructions STRAND SUBSTRATE 38, 76 AND 190 SERIES PRIMED PANEL SIDING INCLUDING SILVERTECH & SMARTFINISH General At the time of manufacture, siding meets or exceeds the performance standards
More informationAPPENDIX DETAIL (1) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS 24 INCHES BELOW GRADE
The sections and construction details in Details 502.2.1.5(1), 502.2.1.5(2), 502.2.1.5(3), 502.2.1.5(4) and 502.2.1.5(5), and Tables 502.2.3.1(1), 502.2.3.1(2), 502.2.3.1(3), 502.2.3.2, 502.2.3.3, 502.2.3.5
More informationBrick Walls MTI. Rainscreen Retrofit for. Flood Recovery Hurricane Recovery Restoration Flood Resilient Retrofit. Guide to Wet Flood-Proofing
Rainscreen Retrofit for Brick Walls Flood Recovery Hurricane Recovery Restoration Flood Resilient Retrofit Revised 1/14/19 Guide to Wet Flood-Proofing MTI MASONRY TECHNOLOGY INCORPORATED Note: The retrofit
More informationCarpentry. The following describes the scope and sequence of instruction for Carpentry.
Carpentry The Montgomery County Students Construction Trades Foundation, Inc has developed a comprehensive construction technology program designed to prepare students for a rewarding career in the construction
More informationREPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3914 Reissued 10/2017 This report is subject to renewal 10/2018. DIVISION: 07 00
More informationEffective Envelope Design Mitigating Risk with High Performance Panels and Acrylic Flashing Systems
Effective Envelope Design Mitigating Risk with High Performance Panels and Acrylic Flashing Systems Presented by: Cale Kids & Sean Smith Huber Engineered Woods Disclaimer: This presentation was developed
More informationESR-1791 Reissued December 1, 2013 This report is subject to renewal December 1, 2015.
ICC-ES Evaluation Report ESR-1791 Reissued December 1, 2013 This report is subject to renewal December 1, 2015. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council
More informationESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.
ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015. A Subsidiary of the International Code Council DIVISION:
More informationHP+ Wall System X Series Technical Installation Manual
HP+ Wall System HP+ Wall System X Series Technical Installation Manual Issue Date: July 26, 2016 Only the most recent published installation manual should be used. The most recent document is available
More informationPLYWOOD FLOATING FLOOR
PLYWOOD FLOATING FLOOR Read First These suggestions represent generally accepted procedures for successful installation of Enka Building Products. These instructions may be followed, modified, or rejected
More informationINTERNATIONAL CODE COUNCIL 2009/2010 CODE DEVELOPMENT CYCLE
INTENATIONAL CODE COUNCIL 09/10 CODE DEVELOPMENT CYCLE 09/10 FINAL ACTION AGENDA UPDATE #2 INTENATIONAL ENEGY CONSEVATION CODE Updated 10-22-10 October 25. 27-31, 10 CHALOTTE CONVENTION CENTE CHALOTTE,
More informationDuPont Tyvek Water- Resistive and Air Barriers Installation Guidelines
DuPont Tyvek Water-Resistive and Air Barriers Installation Guidelines DuPont Tyvek Water- Resistive and Air Barriers Installation Guidelines FOR OPEN STUD CONSTRUCTION FOR BUILDINGS LESS THAN 5 STORIES
More informationNEXT GENERATION HIGH PERFORMANCE WALLS
CONSTRUCTION GUIDE NEXT GENERATION HIGH PERFORMANCE WALLS CLIMATE ZONES 3-5 PART 2: 2X4 Walls with 1" 1.5" Exterior Insulative Sheathing V. Kochkin and J. Wiehagen Home Innovation Research Labs June 2017
More informationResidential Energy Code Update
Residential Energy Code Update www.phrc.psu.edu August 28 th, 2018 Brian Wolfgang Provider # 60114115 PPP ID: 1562 Description On May 1, 2018, the PA Uniform Construction Code (PA UCC) Review and Advisory
More informationCity of High Point Airport Overlay District Noise Level Reduction Design Standards
City of High Point Airport Overlay District Noise Level Reduction Design Standards Part A. Residential Design Standards for Zone 3 I. NOISE LEVEL REDUCTION (NLR) REQUIREMENT FOR ZONE 3. The City of High
More informationDesign No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1
FIRESTOP JOINT SPRAY CFS-SP WB SILICONE JOINT SPRAY CFS-SP SIL F-RATING 2-HR. 2-HR. T-RATING -HR. -HR. APPLICATION THICKNESS PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table /8" WET FILM (/6"
More informationRESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE. Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD 80
RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD 80 Contents Introduction How to Use this Guide...1 Split-Insulation Wall Assembly...2
More informationDecember 11, 2014 Pacific Gas and Electric Territory. Next Generation Construction and the 2016 Code: High R-Value Walls
December 11, 2014 Pacific Gas and Electric Territory Next Generation Construction and the 2016 Code: High R-Value Walls Using GoToWebinar Minimize or expand the pane Choose audio mode Type questions Please
More informationProject Name: Enforcement Agency: Permit Number:
Installation (Page 1 of 4) If more than one person has responsibility for installation of the items on this certificate, each person shall prepare and sign a certificate applicable to the portion of construction
More informationIntroducing TJ Insulated Structural Framing Components
#TJ-9009 SPECIFIER S GUIDE TJ INSULATED HEADERS, RIM BoaRD, AND CORNERS Introducing TJ Insulated Structural Framing Components Helps meet the 2011 Federal Energy Star Homes and 2009 International Energy
More informationInternational Code Council
International Code Council ICC 400-2012 edition Standard on the Design and Construction of Log Structures Public Comments Draft #1 The ICC Standard Development Committee on Log Structures (IS-LOG committee)
More informationEclipse Energy Guard. Product Information & Installation Manual General Installation Requirements
Product Information & Installation Manual 01 Important Notice to Buyers and Users of RoyOMartin wall system These instructions are not intended to cover every installation requirement, application, detail
More informationEnergy Code Math for Commercial Walls: How polyiso continuous insulation can help
Energy Code Math for Commercial Walls: How polyiso continuous insulation can help April 10, 2018 [1] Photo Johns Manville by Timothy Ahrenholz It is an easy mistake to make. For example, when one comes
More information1. PREINSPECTION RESIDENTIAL ENERGY EFFICIENCY 7
Chapter 4 Residential Energy Efficiency [Residential structures include R-3 buildings; R-2 and R-4 buildings three stories or less in height built to the International Building Code (see IBC classifications)]
More informationEnergy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort
Please add relevant logo here Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort Presented by: Peter J. Arsenault, FAIA, NCARB, LEED-AP Disclaimer: This presentation was developed by
More informationStone and Masonry Veneer
Stone and Masonry Veneer R703.7 Stone and masonry veneer, general. Stone and masonry veneer shall be installed in accordance with this chapter, Table R703.4 and Figure R703.7. These veneers installed over
More informationStrategies for Meeting California s High Performance Attics and Walls Prescriptive requirements in California s 2016 Building Energy Efficiency
Strategies for Meeting California s High Performance Attics and Walls Prescriptive requirements in California s 2016 Building Energy Efficiency Standards by Steve Easley, Steve Easley & Associates Inc.
More informationTechnical Data Sheet
Technical Data Sheet ProGUARD Concrete Insulated Sheathing Specifications & Installation Table Of Contents Product Description... pg. 1 Basic Use... pg. 1 Exterior Finishes... pg. 1 Standard Sizes... pg.
More informationDIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2182 Reissued 08/2018 This report is subject to renewal 06/2019. DIVISION: 06 00
More informationRESIDENTIAL INSULATED SHEATHING COMFORTBOARD. Installation Guide
RESIDENTIAL INSULATED SHEATHING TM COMFORTBOARD 80 Installation Guide Table of Contents Introduction How to Use this Guide...1 Split-Insulation Wall Assembly...2 Insulation... 3 Nominal and Effective R-Values
More information(Project Location) (your firm's name)
SECTION 07 21 00 THERMAL INSULATION PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including the Conditions of the Contract and Division 01 Specification Sections
More informationINSTALLATION INSTRUCTIONS
EnergyShield Continuous Wall Insulation INSTALLATION INSTRUCTIONS EnergyShield and EnergyShield CGF CONNECTING FUNCTION WITH FACILITY EnergyShield and EnergyShield CGF Installation Instructions Conditions
More informationDIVISION 07 SECTION 2100 Short Form Guide Specification THERMAL, AIR BARRIER AND WATER BARRIER WALL SYSTEM
DIVISION 07 SECTION 2100 Short Form Guide Specification THERMAL, AIR BARRIER AND WATER BARRIER WALL SYSTEM PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Provide a thermal, air barrier and water resistive
More informationINSTALLATION INSTRUCTIONS ENERGYSHIELD AND RBOARD USE IN CANADA
INSTALLATION INSTRUCTIONS ENERGYSHIELD AND RBOARD USE IN CANADA www.atlaswallci.com EnergyShield and Rboard Installation Instructions Conditions of Use EnergyShield and Rboard rigid foam insulation boards
More information