1 ICC-ES Legacy Report ER-5885 Reissued March (800) (562) A Subsidiary of the International Code Council Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code DIVISION: 03 CONCRETE Section: Cementitious Underlayment LEVELROCK BRAND 2500, 3500, 4500 AND RH FLOOR UNDERLAYMENT PRODUCTS USG CORPORATION 125 SOUTH FRANKLIN STREET CHICAGO, ILLINOIS SUBJECT LEVELROCK Brand 2500, 3500, 4500 and RH Floor Underlayment Products. 2.0 DESCRIPTION 2.1 General: LEVELROCK Brand 2500, 3500, 4500, and RH Floor Underlayments are gypsum cement underlayments used for sound insulation and fire-resistance of floor/ceiling assemblies in accordance with Appendix Chapter 12 and Chapter 7, respectively, of the 1997 Uniform Building Code (UBC); Section 1206 and Chapter 7, respectively, of the 2000 International Building Code (IBC); and Appendix K and Section R321, respectively, of the 2000 International Residential Code (IRC), for use over precast concrete plank, plywood subfloors and poured concrete in new construction, and over concrete and wood floors in existing structures. The underlayments are also used as leveling agents. Floor coverings, such as ceramic tile, vinyl tile, carpeting, and wood, are applied over the underlayment. 2.2 Materials: LEVELROCK Brand Underlayments: The gypsum cement floor underlayment has a dry density (aggregated) of 115 to 125 pounds per cubic foot (1842 to 2002 kg/m 3 ). LEVELROCK Brand 2500 Floor Underlayment is applied at a minimum 3 / 4 -inch (19.1 mm) thickness over plywood substrates in wood-framed construction. LEVELROCK Brand 2500 Floor Underlayment is formulated to achieve a compressive strength from 2,000 psi to 3,000 psi (13.8 to 20.7 MPa). Mix proportions are 80 pounds (36.3 kg) of LEVELROCK Brand 2500 (one bag), 1.9 cubic feet (0.054 m 3 ) of sand, and 4.5 to 5.0 gallons (17.0 to 18.9 L) of potable water. Shelf life of the bagged material is six months when the material is stored in dry conditions. LEVELROCK Brand 3500 Floor Underlayment is applied at thicknesses up to 1 inch (25.4 mm) over wood and concrete subfloors. LEVELROCK Brand 3500 is formulated to achieve a compressive strength from 3,000 psi to 4,000 psi (20.7 to 27.6 MPa). Mix proportions are 80 pounds (36.3 kg) of LEVELROCK Brand 3500 (one bag), 1.6 cubic feet (0.045 m 3 ) of sand, and 4.0 to 4.5 gallons (15.1 to 17.0 L) of potable water. Shelf life of the bagged material is six months when the material is stored in dry conditions. LEVELROCK Brand 4500 Floor Underlayment is applied over concrete slabs, prefabricated-stressed concrete or concrete planks to a maximum thickness of 3 inches (76 mm). The underlayment is formulated to achieve a compressive strength from 4,000 psi to 5,000 psi (27.6 to 34.5 MPa). Mix proportions are 80 pounds (36.3 kg) of LEVELROCK Brand 4500 (one bag), 1.6 cubic feet (0.045 m 3 ) of sand, and 4.0 to 4.5 gallons (15.1 to 17.0 L) of potable water. Shelf life of the bagged material is four months when stored in dry conditions. LEVELROCK Brand RH (Radiant Heat) Floor Underlayment is specifically formulated for electric and hot water radiant heat floor installations. LEVELROCK Brand RH Floor Underlayment is formulated to achieve a compressive strength from 2,000 to 3,000 psi (13.8 to 20.7 MPa). The underlayment is applied at thicknesses of 3 / 4 inch (19.1 mm), minimum, to 3 inches (76 mm), maximum. Mix proportions are 80 pounds (36.3 kg) of LEVELROCK Brand RH (one bag), 1.6 cubic feet (0.045 m 3 ) of sand, and 4.5 to 5.0 gallons (17.0 to 18.9 L) of potable water. Shelf life of the bagged material is six months when the material is stored in dry conditions Sand: Sand must be clean and contain no more than 1.5 percent water-soluble impurities and no more than 1.0 percent of clay and other contaminants. Sampling, testing and grading must be in accordance with ASTM C Substrates: Plywood and OSB substrates must be a minimum of 23 / 32 inch thick (18.3 mm), with tongue- and groove-edges, must comply with UBC Standard 23-2 or 23-3 (UBC) or PS-1 or PS-2 (IBC and IRC), respectively, as applicable, and must comply with UBC Tables 23-II-E-1 and 23-II-E-2 or IBC Tables (3) and (4). Concrete substrates must comply with Chapter 19 of the UBC or IBC. Maximum permitted deflection of substrates under total load is L/360, where L is the distance between support joists or beams Primer: LEVELROCK Brand Ready Mix PRIMER is applied to wood and concrete substrates before application of the underlayment. The primer is applied, ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2014 Page 1 of

2 ER-5885 Most Widely Accepted and Trusted Page 2 of 4 without dilution, by spraying, rolling or with a broom at a maximum coverage of 400 square feet per gallon (9.8 m 2 /L). 2.3 Application: The materials are mixed at the jobsite and are pumped into place by applicators approved by USG Corporation. Substrates must be clean, dry, and free of mud, grease, oil or other contaminants that affect the bond. All grouting must be done at least 30 days before application of the underlayment. Wood substrates must be primed before underlayment application. Concrete substrates must cure a minimum of 28 days before application of primer or underlayment. Conduits and pipes embedded in the LEVELROCK must have a minimum cover of 3 / 4 inch (19.1 mm) in accordance with Section of the UBC and Section 1906 of the IBC. 2.4 Sound Control: Assembly 1: The assembly consists of 1-inch-thick (25.4 mm) LEVELROCK Brand 2500, 3500, 4500 or RH Underlayment poured over Enkasonic 9110 acoustical mat (ER-4778), with duct tape applied along the seams of the mat. The mat is loose laid over 23 / 32 -inch-thick (18.3 mm), APA-rated Sturdifloor plywood attached to 18-inch-deep, open web, parallel chord 2-by-4 lumber trusses using 2-inch-long (51 mm) galvanized steel screws spaced at 12 inches (305 mm) on center. The trusses are spaced a maximum of 24 inches (610 mm) on center. The joist cavities contain a layer of 3 1 / 2 -inch-thick (89 mm), unfaced R-11 fiberglass insulation attached to the underside of the floor deck with steel clips. Resilient channels, spaced at 16 inches (406 mm) on center, are attached to the bottom chord of the trusses using 1.25-inch-long (31.7 mm) Type W screws, one screw per truss and channel intersection. Minimum 5 / 8 -inch-thick (15.9 mm) USG SHEETROCK Brand Firecode C gypsum panels are attached perpendicular to the resilient channels using 1-inch-long (25.4 mm), Type S bugle head drywall screws spaced at 12 inches (305 mm) on center. End joints of gypsum panels must be supported by resilient channels. Joints in the gypsum panels must be taped and treated with joint Screw heads must be covered with joint The assembly as described has a sound transmission class (STC) rating of 50 or greater. When 0.07-inch-thick (2 mm) Armstrong Caspian sheet vinyl; 24-ounce-persquare-yard (813.7 g/m 2 ) carpeting and 7 / 16 -inch-thick (11.1 mm), 6 psf (29.3 kg/m 2 ) foam pad; or 5 / 16 -inch-thick (7.9 mm) ceramic tile, is applied over the underlayment, the impact insulation class (IIC) rating of the assembly is 50 or greater. See Figure Assembly 2: The assembly consists of 1-inch-thick (25.4 mm) LEVELROCK Brand 2500, 3500, 4500 or RH Underlayment poured over 0.4-inch-thick (10.2 mm) Enkasonic 9110 acoustical mat with duct tape applied along the seams of the mat. The mat is loose laid over 23 / 32 -inch-thick (18.3 mm) APA-rated Sturdifloor plywood attached to 9 1 / 2 -inch-deep (241 mm), wood I-joists, using 2-inch-long (51 mm) galvanized steel screws spaced at 12 inches (305 mm) on center. The I-joists are spaced a maximum of 24 inches (610 mm) on center. The joist cavities contain a layer of 3 1 / 2 -inch-thick (89 mm), unfaced R-11 fiberglass insulation attached to the underside of the floor deck with steel clips. Resilient channels, spaced at 16 inches (406 mm) on center, are attached to the bottom chord of the I-joists using 1.25-inch-long (31.7 mm), Type W screws, one screw per truss and channel intersection. Minimum 5 / 8 -inch-thick (15.9 mm) USG SHEETROCK Brand Fire-code C gypsum panels are attached perpendicular to the resilient channels using 1-inch-long (25.4 mm), Type S bugle head drywall screws spaced at 12 inches (305 mm) on center. Joints in the gypsum board must be taped and treated with joint Screw heads must be covered with joint The assembly as described has a sound transmission class (STC) rating of 50 or greater. When 0.07-inch-thick (2 mm) Armstrong Caspian sheet vinyl; 24 ounce per square yard (813.7 g/m 2 ) carpeting and 7 / 16 -inch-thick (11.1 mm), 6 psf (29.3 kg/m 2 ) foam pad; or 8 mm thick PERGO laminate flooring over PERGO SOUNDBLOC foam, is applied over the underlayment, the impact insulation class (IIC) rating of the assembly is 50 or greater. See Figure Assembly 3: The assembly consists of 3 / 4 -inchthick (19 mm) LEVELROCK Brand 2500, 3500, 4500, or RH Underlayment poured over a 3 / 8 -inch-thick (9.5 mm) USG Levelrock Brand Sound Reduction Board. The board is loosely laid over 23 / 32 -inch-thick (18.3 mm), APA-rated, tongue-and-groove Sturdifloor OSB attached to 9½-inchdeep (241 mm) wood I-joists, using 2-inch-long (51 mm) galvanized steel screws spaced at 12 inches (305 mm) on center. The I-joists are spaced a maximum of 24 inches (610 mm) on center. The joist cavities contain a layer of 3 1 / 2 -inch-thick (89 mm), unfaced, R-11, fiberglass insulation attached to the underside of the floor deck with steel clips. Resilient channels, spaced at 16 inches (406 mm) on center, are attached to the bottom chord of the I-joists using 1 1 / 4 -inch-long (31.7 mm), Type W screws, one screw per joist and channel intersection. Two layers of 1 / 2 -inch-thick (12.7 mm) USG SHEETROCK Brand Firecode C gypsum panels are attached perpendicular to resilient channels using 1-inch-long (25.4 mm), Type S bugle head drywall screws for the base layer, and 1 5 / 8 -inch-long (41.2 mm), Type S bugle head drywall screws for the face layer. Screw spacing for both layers is 12 inches (305 mm) on center in the field of the panels and 8 inches on center (203 mm) at the butt joints. Joints on the face layer must be taped and treated with joint compound; screw heads must be covered with joint The assembly as described above with floor covering of 5 / 16 -inch-thick (8 mm) Pergo Original wood laminate flooring over a 0.05-inch-thick (1.3 mm) Pergo SoundBlock foam; inch-thick (1.6 mm) sheet vinyl flooring; or ceramic tiles, nominally 3 / 16 inch (4.75 mm) thick, adhered to a 0.03-inch (0.76 mm) crack isolation sheet, provides a sound transmission class (STC) rating of 50 or greater and an impact insulation class (IIC) rating of 50 or greater. See Figure Assembly 4: The assembly consists of 1-inch-thick (25.4 mm) LEVELROCK Brand 2500, 3500, 4500, or RH Underlayment poured over a 1 / 4 -inch-thick (6.5 mm) USG LEVELROCK Brand SRM-25 Sound Reduction Mat. The mat is laid directly over but not attached to 23 / 32 -inch-thick, APA-rated, tongue-and-groove Sturdifloor OSB attached to 9 1 / 2 -inch-deep (241 mm) I-joists, using 1 1 / 2 -inch-long (38 mm) galvanized steel screws spaced at 12 inches (305 mm) on center. The I-joists are spaced a maximum of 24 inches (610 mm) on center. The joist cavities contain a layer of 3 1 / 2 -inch-thick (89 mm), unfaced, R-11 fiberglass insulation attached to the underside of the floor deck with steel clips. Resilient channels, spaced at 16 inches (406 mm) on center, are attached to the bottom chord of the I-joists using 1 1 / 4 -inch-long (31.7 mm), Type W screws, one screw per joist and channel intersection. Two layers of 1 / 2 -inch-thick (12.7 mm) USG SHEETROCK BRAND FIRECODE C gypsum panels are attached perpendicular to resilient channels using 1-inch-long (25.4 mm), Type S bugle head drywall screws for the base layer, and

3 ER-5885 Most Widely Accepted and Trusted Page 3 of / 8 -inch-long (41.2 mm), Type S bugle head drywall screws for the face layer. Screw spacing for both layers is 12 inches (305 mm) on center in the field of the panels and 8 inches on center (203 mm) at the butt joints. Joints on the face layer must be taped and treated with joint compound; screw heads must be covered with joint The assembly as described above with floor covering of 5 / 16 -inch-thick (8 mm) Pergo Original wood laminate flooring over a 0.05-inch-thick (1.3 mm) Pergo SoundBlock foam; inch-thick (1.6 mm) sheet vinyl flooring; or ceramic tiles, nominally 3 / 16 inch (4.75 mm) thick, provides a sound transmission class (STC) rating of 50 or greater and an impact insulation class (IIC) rating of 50 or greater. See Figure One-hour Fire-resistive Construction: The assembly consists of 3 / 4 -inch-thick (19.1 mm) LEVELROCK Brand 2500, 3500, 4500 or RH Underlayment poured over minimum 1 / 2 -inch-thick (12.7 mm) plywood attached to nominal 2-by-10 wood joists spaced a maximum of 16 inches (610 mm) on center using 8d sinker nails spaced at 10 inches (254 mm) on center. The plywood is oriented perpendicular to the joists and must be staggered a minimum of 32 inches (813 mm). Three-inch-wide-by- 1 / 2 -inch-deep (76 mm by 12.7 mm), No. 22 gage furring channels are attached perpendicular to the joists, spaced a maximum of 24 inches (610 mm) on center, using 1 1 / 4 -inch-long (31.7 mm) inchdiameter-shank (3.8 mm), self-drilling, self-tapping screws, one screw per joist/channel intersection. Minimum 1 / 2 -inchthick (12.7 mm) USG SHEETROCK Brand Firecode C gypsum boards are attached perpendicular to the resilient channels using 1-inch-long (25.4 mm) Type S bugle head drywall screws spaced at 12 inches (305 mm) on center. End joints in the gypsum board must be staggered a minimum of 48 inches (1219 mm) between adjacent rows. Joints in the gypsum board must be taped and treated with joint Screw heads must be covered with joint 2.6 Identification: LEVELROCK Brand floor underlayments are identified by the USG Corporation name and address, the product name, the date code and the evaluation report number (ER-5885). 3.0 EVIDENCE SUBMITTED Reports of tests in accordance with UBC Standard 7-1; reports of density and compressive strength tests; soundinsulation tests in accordance with ASTM Standards E 90-97, E (1980) and E (1996); product information; and a quality control manual. 4.0 FINDINGS That the LEVELROCK Brand 2500, 3500, 4500, and RH Floor Underlayments described in this report comply with the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code, provided the installation is in accordance with this report and the manufacturer s installation instructions, and the installation is done by applicators approved by USG Corporation. This report is subject to re-examination in one year. FIGURE 1 SOUND CONTROL ASSEMBLY 1 FIGURE 2 SOUND CONTROL ASSEMBLY 2

4 ER-5885 Most Widely Accepted and Trusted Page 4 of 4 FIGURE 3 SOUND CONTROL ASSEMBLY 3 FIGURE 4 SOUND CONTROL ASSEMBLY 4

5 ICC-ES Legacy Report ER-5885 Supplement Issued June (800) (562) A Subsidiary of the International Code Council Filing Category: FIRE-RESISTIVE CONSTRUCTION Other Fire-resistive Construction LEVELROCK BRAND 2500, 3500, 4500 AND RH FLOOR UNDERLAYMENT PRODUCTS USG CORPORATION 125 SOUTH FRANKLIN STREET CHICAGO, ILLINOIS SUBJECT LEVELROCK Brand 2500, 3500, 4500 and RH Floor Underlayment Products. (Issued October 1, 2001.) Reduce minimum floor underlayment thickness in Section 2.5 of the report from 1 inch (25.1 mm) to 3 / 4 inch (19.1 mm). 2.0 DESCRIPTION 2.1 General: No change. 2.2 Materials: No change. 2.3 Application: No change. 2.4 Sound Control: No change. 2.5 One-hour Fire-resistive Construction: Revise the first sentence as follows: The assembly consists of 3 / 4 -inch-thick (19.1 mm) LEVELROCK Brand 2500, 3500, 4500 or RH Underlayment poured over minimum 1 / 2 -inch-thick (12.7 mm) plywood attached to nominal 2-by-10 wood joists spaced a maximum of 16 inches (610 mm) on center using 8d sinker nails spaced at 10 inches (254 mm) on center. 2.6 Identification: No change. 3.0 EVIDENCE SUBMITTED No change. 4.0 FINDINGS That the changes noted herein comply with the 1997 Uniform Building Code, provided the installation is in accordance with this report and the manufacturer s installation instructions, and the installation is done by applicators approved by USG Corporation. Unless specifically noted in this evaluation report supplement, the master report remains valid and unchanged. This report expires concurrently with the master report dated June ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2014 Page 1 of

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: ECORE INTERNATIONAL, INC.

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: ECORE INTERNATIONAL, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1522 Reissued 09/2016 This report is subject to renewal 09/2018. DIVISION: 09 00

More information

REPORT HOLDER: KINETICS NOISE CONTROL 6300 IRELAN PLACE DUBLIN, OHIO EVALUATION SUBJECT: KINETICS NOISE CONTROL WAVE HANGER

REPORT HOLDER: KINETICS NOISE CONTROL 6300 IRELAN PLACE DUBLIN, OHIO EVALUATION SUBJECT: KINETICS NOISE CONTROL WAVE HANGER 0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3207 Reissued 10/2016 This report is subject to renewal 10/2018. DIVISION: 09 00 00 FINISHES

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PEDESTRIAN TRAFFIC COATINGS REPORT HOLDER: AVM INDUSTRIES, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PEDESTRIAN TRAFFIC COATINGS REPORT HOLDER: AVM INDUSTRIES, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2125 Reissued 07/2018 This report is subject to renewal 07/2019. DIVISION: 07 00

More information

DIVISION: CONCRETE SECTION: CEMENTITIOUS WOOD FIBER DECKS DIVISION: FINISHES SECTION: ACOUSTIC ROOM COMPONENTS

DIVISION: CONCRETE SECTION: CEMENTITIOUS WOOD FIBER DECKS DIVISION: FINISHES SECTION: ACOUSTIC ROOM COMPONENTS 0 ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org Most Widely Accepted and Trusted ESR-1112 Reissued 05/2017 Revised 08/2018 This report is subject to renewal 05/2019.

More information

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015. A Subsidiary of the International Code Council DIVISION:

More information

A. Description of Work: Work of this section includes self leveling underlayment for interior finish flooring but is not limited to, the following:

A. Description of Work: Work of this section includes self leveling underlayment for interior finish flooring but is not limited to, the following: SECTION 03540 [03 54 13] Floor Underlayment PART 1 - GENERAL ***Notes to Architect are highlighted in red**** 1.01 SUMMARY A. Description of Work: Work of this section includes self leveling underlayment

More information

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: HOMASOTE COMPANY

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: HOMASOTE COMPANY 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1374 Reissued 06/2017 This report is subject to renewal 06/2018. DIVISION: 09 00

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIRESTOPPING REPORT HOLDER: PASSIVE FIRE PROTECTION PARTNERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIRESTOPPING REPORT HOLDER: PASSIVE FIRE PROTECTION PARTNERS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2996 Reissued 12/2017 This report is subject to renewal 12/2019. DIVISION: 07 00

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: PAREX USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: PAREX USA, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2563 Reissued 03/17 This report is subject to renewal 03/19. DIVISION: 07 00 00 THERMAL

More information

ICC-ES Evaluation Report. ESR-3297 Reissued March 1, 2013 This report is subject to renewal May 1, 2014.

ICC-ES Evaluation Report. ESR-3297 Reissued March 1, 2013 This report is subject to renewal May 1, 2014. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-3297 Reissued March, 203 This report is subject to renewal May, 204. A Subsidiary the International Code Council DIVISION: 07 00

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1365 Reissued 04/2018 This report is subject to renewal 04/2020. DIVISION: 06 00

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I-JOISTS REPORT HOLDER: PACIFIC WOODTECH CORPORATION

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I-JOISTS REPORT HOLDER: PACIFIC WOODTECH CORPORATION 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1225 Reissued 10/2017 This report is subject to renewal 10/2019. DIVISION: 06 00

More information

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: Base 10

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: Base 10 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492 Rendered to Series/Model: Base 10 Specimen Type: Floor/Ceiling Assembly Overall Size: 3023 mm by 3632 mm Summary of Test Results Data File Result

More information

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: Forest rx

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: Forest rx ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492 Rendered to Series/Model: Forest rx Specimen Type: Floor/Ceiling Assembly Overall Size: 3023 mm by 3632 mm Summary of Test Results Data File

More information

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: Expona

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: Expona ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492 Rendered to ECORE International Series/Model: Expona Specimen Type: Floor/Ceiling Assembly Overall Size: 3023 mm by 3632 mm Summary of Test Results

More information

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: QT4005

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: QT4005 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492 Rendered to Series/Model: QT4005 Specimen Type: Floor/Ceiling Assembly Overall Size: 3023 mm by 3632 mm Summary of Test Results Data File Result

More information

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: QT4002

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: QT4002 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492 Rendered to Series/Model: QT4002 Specimen Type: Floor/Ceiling Assembly Overall Size: 3023 mm by 3632 mm Summary of Test Results Data File Result

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2182 Reissued 08/2018 This report is subject to renewal 06/2019. DIVISION: 06 00

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC. 0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3500 Reissued 01/2016 This report is subject to renewal 01/2017. DIVISION: 07 00 00 THERMAL

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PEDESTRIAN TRAFFIC COATINGS REPORT HOLDER: WESTCOAT

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PEDESTRIAN TRAFFIC COATINGS REPORT HOLDER: WESTCOAT 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2201 Reissued 07/2016 This report is subject to renewal 07/2018. DIVISION: 07 00

More information

Joint Evaluation Report

Joint Evaluation Report 0 Joint Evaluation Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 ESR 1040 Reissued 09/2018 Revised 03/2019 This report is subject to renewal 09/2019. DIVISION: 06 00 00 WOOD, PLASTICS

More information

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued October 1, Legacy report on the 1997 Uniform Building Code

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued October 1, Legacy report on the 1997 Uniform Building Code LEGACY REPORT Reissued October 1, 2007 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900 Montclair

More information

RSIC ACOUSTIC ASSEMBLY

RSIC ACOUSTIC ASSEMBLY RSIC ACOUSTIC ASSEMBLY FLOOR CEILING ASSEMBLY DIRECT FIX TO WOOD OPEN WEB TRUSS TFCSW RAL IN09-044 STC 54 IIC 52 CONSTRUCTION Hardwood Flooring 1/16" Foam Underlayment 3/4 T&G OSB Subfloor 11-1/4" Deep

More information

Joint Evaluation Report

Joint Evaluation Report 0 Joint Evaluation Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 ESR-1040 Reissued 09/2018 This report is subject to renewal 09/2019. DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES SECTION:

More information

Joint Evaluation Report

Joint Evaluation Report 0 Joint Evaluation Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 ESR-1040 Reissued 09/2016 This report is subject to renewal 09/2018. DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES SECTION:

More information

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code LEGACY REPORT Reissued January 1, 2000 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900 Montclair

More information

REPORT HOLDER: GYPSUM ASSOCIATION 6525 BELCREST ROAD #480 HYATTSVILLE, MARYLAND EVALUATION SUBJECT:

REPORT HOLDER: GYPSUM ASSOCIATION 6525 BELCREST ROAD #480 HYATTSVILLE, MARYLAND EVALUATION SUBJECT: 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-338 Reissued 02/206 This report is subject to renewal 02/207. DIVISION: 09 00 00 FINISHES SECTION:

More information

ICC-ES Evaluation Report Reissued February 1, 2011 This report is subject to re-examination in one year.

ICC-ES Evaluation Report Reissued February 1, 2011 This report is subject to re-examination in one year. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1826 Reissued February 1, 2011 This report is subject to re-examination in one year. A Subsidiary of the International Code Council

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1780 Reissued 11/2017 This report is subject to renewal 11/2019. DIVISION: 06 00

More information

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015. A Subsidiary of the International Code Council

More information

ICC-ES Evaluation Report Reissued February 1, 2012 This report is subject to renewal February 1, 2013.

ICC-ES Evaluation Report Reissued February 1, 2012 This report is subject to renewal February 1, 2013. * ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1826* Reissued February 1, 2012 This report is subject to renewal February 1, 2013. A Subsidiary of the International Code Council

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3909 Issued 07/2017 This report is subject to renewal 07/2018. DIVISION: 07 00 00

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2445 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 06 00

More information

REPORT HOLDER: GYPSUM ASSOCIATION 962 WAYNE AVENUE, SUITE 620 SILVER SPRING, MARYLAND EVALUATION SUBJECT:

REPORT HOLDER: GYPSUM ASSOCIATION 962 WAYNE AVENUE, SUITE 620 SILVER SPRING, MARYLAND EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 338 Reissued 02/208 This report is subject to renewal 02/209. DIVISION: 09 00 00

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: LAPOLLA INDUSTRIES, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3916 Reissued 09/2017 This report is subject to renewal 09/2019. DIVISION: 07 00

More information

ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015.

ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015. * ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015. A Subsidiary of the International Code Council

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3392 Reissued 06/2018 This report is subject to renewal 06/2019. DIVISION: 07 00

More information

FLOOR CEILING ASSEMBLY

FLOOR CEILING ASSEMBLY FLOOR CEILING ASSEMBLY DIRECT FIX TO SOLID WOOD JOIST FCWT RAL IN09-012 Toll Free (866) 774-2100 WWW.PAC-INTL.COM Fire Resistance Ratings CONSTRUCTION 3/8" HARDWOOD FLOORING VAPOR BARRIER 3/4 LT WT CONCRETE

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3392 Reissued 06/2017 This report is subject to renewal 06/2018. DIVISION: 07 00

More information

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.orgg ESR 2562 Reissued 08/206 This report is subject to renewal 08/208. DIVISION: 07 00 00

More information

Floor Underlayment Selector High-Strength Flooring Solutions

Floor Underlayment Selector High-Strength Flooring Solutions Levelrock Selector High-Strength Flooring Solutions With its wide range of installation and performance benefits, poured underlayment is becoming the choice for more residential, commercial and institutional

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: DRYVIT SYSTEMS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: DRYVIT SYSTEMS, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 232 Reissued 0/207 This report is subject to renewal 0/209. DIVISION: 07 00 00 THERMAL

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PEDESTRIAN TRAFFIC COATINGS REPORT HOLDER: PLI DEK LLC EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PEDESTRIAN TRAFFIC COATINGS REPORT HOLDER: PLI DEK LLC EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2097 Reissued 08/208 This report is subject to renewal 08/209. DIVISION: 07 00 00THERMAL

More information

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1530 Reissued 09/2017 This report is subject to renewal 09/2019. DIVISION: 03 00

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PEDESTRIAN TRAFFIC COATINGS REPORT HOLDER: PLI DEK LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PEDESTRIAN TRAFFIC COATINGS REPORT HOLDER: PLI DEK LLC 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2097 Reissued 08/207 This report is subject to renewal 08/208. DIVISION: 07 00 00THERMAL

More information

ESR-1812 Reissued October 1, 2012 This report is subject to renewal November 1, 2013.

ESR-1812 Reissued October 1, 2012 This report is subject to renewal November 1, 2013. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1812 Reissued October 1, 2012 This report is subject to renewal November 1, 2013. A Subsidiary of the International Code Council

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2119 Reissued 08/2017 This report is subject to renewal 08/2019. DIVISION: 07 00

More information

FOR: CEMCO - California Expanded Metal Products Co. Sound Transmission Loss Test

FOR: CEMCO - California Expanded Metal Products Co. Sound Transmission Loss Test FOR: CEMCO - California Expanded Metal Products Co. Sound Transmission Loss Test Industry, CA ON: Bare 1 Inch Thick USG LEVELROCK Brand CSD Floor Underlayment on USG LEVELROCK SRM-25 Sound Mat on CEMCO

More information

GenieMat FF. Floating Floor Systems for Airborne & Impact Sound and Vibration Isolation. It s not magic, it s engineering. Impact Sound Control

GenieMat FF. Floating Floor Systems for Airborne & Impact Sound and Vibration Isolation. It s not magic, it s engineering. Impact Sound Control It s not magic, it s engineering. Impact Sound Control GenieMat FF Floating Floor Systems for Airborne & Impact Sound and Vibration Isolation Patents: US 8240430, US8556029, CA 2500956, CA 2503420 GenieMat

More information

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3833 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 03 00

More information

ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year.

ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year. ICC-ES Evaluation Report ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316 LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316 International Beams Inc. 2010 Boul. St-Elzear Quest Laval, QC H7L 3N4 CANADA This report is for the exclusive use of Intertek

More information

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: METACRYLICS

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: METACRYLICS 0 Most Widely Accepted and Trusted ICC ES Legacy Report ICC ES 000 (800) 6587 (56) 699 05 www.icc es.org ER 785 Reissued 09/017 This report is subject to renewal 09/0. DIVISION: 07 00 00THERMAL AND MOISTURE

More information

RSIC ACOUSTIC ASSEMBLY

RSIC ACOUSTIC ASSEMBLY RSIC ACOUSTIC ASSEMBLY FLOOR CEILING ASSEMBLY DIRECT FIX TO SOLID WOOD JOIST FCWT RAL IN08-016 CONSTRUCTION Sheet Vinyl 1/2 Wood Underlayment 5/8 Plywood Subfloor (*L513 3/4 Ply) 2" X 10" Solid Wood Joist

More information

Stark Truss Company, Inc. Revised December 14, 2018

Stark Truss Company, Inc. Revised December 14, 2018 Fire-Rated Assemblies PR-S223 Stark Truss Company, Inc. Revised December 14, 2018 Products: SI-40, SI-60, and SI-80 Prefabricated Wood I-Joists Stark Truss Company, Inc. 8655 Chestnut Ridge Road, N.W.

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: REDBUILT LLC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: REDBUILT LLC 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2994 Reissued 08/2017 This report is subject to renewal 08/2019. DIVISION: 06 00

More information

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1473 Reissued 09/2017 This report is subject to renewal 09/2019. SECTION: 06 16 00

More information

RSIC ACOUSTIC ASSEMBLY

RSIC ACOUSTIC ASSEMBLY RSIC ACOUSTIC ASSEMBLY FLOOR CEILING ASSEMBLY DIRECT FIX TO WOOD OPEN WEB TRUSS TFCSW RAL IN09-045 STC 56 IIC 73 CONSTRUCTION Carpet and Pad 3/4 T&G OSB Subfloor 11-1/4" Deep Open Web Truss @ 24" OC R-11

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: LAPOLLA INDUSTRIES, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2629 Reissued 12/2017 This report is subject to renewal 12/2019. DIVISION: 07 00

More information

USG LEVELROCK BRAND SOUND REDUCTION BOARD SRB

USG LEVELROCK BRAND SOUND REDUCTION BOARD SRB USG Tile & Flooring Solutions SUBMITTAL SHEET USG LEVELROCK BRAND SOUND REDUCTION BOARD SRB Economical, high-performance sound reduction board Provides excellent sound control Sound systems meet or exceed

More information

BXUV.L576 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263

BXUV.L576 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263 Page 1 of 7 Page Bottom BXUV.L576 Fire Resistance Ratings - ANSI/UL 263 Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - ANSI/UL 263 Design No. L576 August 15,

More information

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal March 1, 2015

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal March 1, 2015 ICC-ES Evaluation Report ESR-1694 Reissued March 2014 This report is subject to renewal March 1, 201 www.icc-es.org (800) 423-687 (62) 699-043 A Subsidiary of the International Code Council DIVISION: 07

More information

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: ULTRAKOTE PRODUCTS, LLC

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: ULTRAKOTE PRODUCTS, LLC 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1471 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 09 00

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: KMEW CO., LTD. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: KMEW CO., LTD. EVALUATION SUBJECT: 0 ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org Most Widely Accepted and Trusted ESR 1627 Reissued 12/2018 This report is subject to renewal 12/2020. DIVISION: 07 00

More information

ESR-1013 Reissued January 1, 2012 This report is subject to renewal in two years.

ESR-1013 Reissued January 1, 2012 This report is subject to renewal in two years. ICC-ES Evaluation Report ESR-1013 Reissued January 1, 2012 This report is subject to renewal in two years. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 4 6587 (562) 699 0543 www.icc es.org ESR 3152 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC 0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3210 Valid: 03/15 to 03/16 DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 21

More information

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SOMAR INDUSTRIES LTD LUCKETT COURT EL PASO, TEXAS 79932

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SOMAR INDUSTRIES LTD LUCKETT COURT EL PASO, TEXAS 79932 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2732 Reissued 11/2017 This report is subject to renewal 11/2019. DIVISION: 09 00

More information

FIRM-FILL SCM-400 can be installed under a FIRM-FILL Gypsum Concrete Floor Underlayment to produce an exceptional vibration isolation floor system.

FIRM-FILL SCM-400 can be installed under a FIRM-FILL Gypsum Concrete Floor Underlayment to produce an exceptional vibration isolation floor system. Specify FILL SCM-400 for additional impact noise control when a thicker sound mat is needed. It helps achieve higher delta numbers than thinner mats. FILL SCM-400 is a cost-effective way to address Impact

More information

HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction.

HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction. HACKER SOUND MAT II HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction. HACKER SOUND MAT II, a recycled rubber sound

More information

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (00) 423-657 (562) 699-0543 www.icc-es.org ESR-2064 Reissued 11/2017 This report is subject to renewal 11/201. DIVISION: 07 00 00

More information

Boise Cascade Company Revised June 25, 2018

Boise Cascade Company Revised June 25, 2018 Fire-Rated Assemblies PR-S255 Boise Cascade Company Revised June 25, 2018 Products: GPI, WI, and BSI I-Joists Boise Cascade Company, 1000 North Park Drive, Roxboro, North Carolina 27573 (336) 599-1000

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PEDESTRIAN TRAFFIC COATINGS REPORT HOLDER: HILL BROTHERS CHEMICAL COMPANY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PEDESTRIAN TRAFFIC COATINGS REPORT HOLDER: HILL BROTHERS CHEMICAL COMPANY 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1661 Reissued 02/2018 This report is subject to renewal 02/2019. DIVISION: 07 00

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: CITADEL ARCHITECTURAL PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: CITADEL ARCHITECTURAL PRODUCTS, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1015 Reissued 04/2017 This report is subject to renewal 04/2019. DIVISION: 07 00

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: COVESTRO, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: COVESTRO, LLC 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1221 Reissued 12/2017 This report is subject to renewal 12/2018. DIVISION: 07 00

More information

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1812 Reissued 11/2017 This report is subject to renewal 11/2018. DIVISION: 09 00

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: DIRECT-APPLIED FINISH SYSTEMS REPORT HOLDER: STO CORP.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: DIRECT-APPLIED FINISH SYSTEMS REPORT HOLDER: STO CORP. 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-2536 Reissued 08/2016 This report is subject to renewal 08/2018. DIVISION: 07 00 00 THERMAL

More information

(800) (562) A Subsidiary of the International Code Council

(800) (562) A Subsidiary of the International Code Council ICC-ES Evaluation Report ESR-1479 Issued July 1, 2009 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED STRUCTURAL WOOD REPORT HOLDER: REDBUILT LLC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED STRUCTURAL WOOD REPORT HOLDER: REDBUILT LLC 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 42 587 (52) 99 054 www.icc es.org ESR 1774 Reissued 08/2017 This report is subject to renewal 08/2019. DIVISION: 0 00 00 WOOD,

More information

PFC-5804* Reissued February 1, Filing Category: DESIGN Wood

PFC-5804* Reissued February 1, Filing Category: DESIGN Wood PFC-50* Reissued February 1, 2003 ICBO Evaluation Service, Inc. 530 Workman Mill Road, Whittier, California 9001 www.icboes.org Filing Category: DESIGN Wood PACIFIC WOODTECH CORPORATION PWI JOISTS PACIFIC

More information

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California *Revised April 2003

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California *Revised April 2003 PFC-5804* Reissued February 1, 2003 ICBO Evaluation Service, Inc. 5360 Workman Mill Road, Whittier, California 90601 www.icboes.org Filing Category: DESIGN Wood PACIFIC WOODTECH CORPORATION PWI JOISTS

More information

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 689 Reissued 07/206 This report is subject to renewal 07/208. DIVISION: 07 00 00

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 3-6587 (562) 699-03 www.icc-es.org ESR-3743 Reissued 08/2017 This report is subject to renewal 08/2019. DIVISION: 07 00 00 THERMAL

More information

PinkWood Ltd. Revised September 29, 2017

PinkWood Ltd. Revised September 29, 2017 Fire-Rated Assemblies PR-S315 PinkWood Ltd. Revised September 29, 2017 Products: Series I-Joists PinkWood Ltd., 5929 6 th St. NE, Calgary, Alberta, Canada T2K 5R5 (403) 279-3700 www.pinkwood.ca 1. Basis

More information

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: BONSAL AMERICAN, INC.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: BONSAL AMERICAN, INC. 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2781 Reissued 02/2017 This report is subject to renewal 02/2018. DIVISION: 09 00 00 FINISHES

More information

3.0 DESCRIPTION. Division: Thermal and Moisture Protection Section: Thermal Insulation

3.0 DESCRIPTION. Division: Thermal and Moisture Protection Section: Thermal Insulation Division: 07 00 00 Thermal and Moisture Protection Section: 07 21 00 Thermal Insulation Report Holder: Icynene Inc. 6747 Campobello Rd. Mississauga, Ontario L5N 2L7 CANADA (905)363-4040 www.icynene.com

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2810 Reissued 02/2018 This report is subject to renewal 07/2018. DIVISION: 07 00

More information

DIVISION: MASONRY SECTION: MANUFACTURED BRICK MASONRY SECTION: MANUFACTURED STONE MASONRY REPORT HOLDER:

DIVISION: MASONRY SECTION: MANUFACTURED BRICK MASONRY SECTION: MANUFACTURED STONE MASONRY REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3685 Reissued 09/2017 This report is subject to renewal 09/2018. SECTION: 04 71 00

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS REPORT HOLDER: 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-3835 Issued 08/2015 This report is subject to renewal 09/2016. DIVISION: 07 00 00 THERMAL AND

More information

Trusted ICC ES. Conformity! Look. Evaluation. ICC-ES Evaluation

Trusted ICC ES. Conformity! Look. Evaluation. ICC-ES Evaluation 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.orgg ESR 3288 Reissued 12/2017 This report is subject to renewal 12/2018. DIVISION: 03 00

More information

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SUPERWALL MANUFACTURING, INC.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SUPERWALL MANUFACTURING, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2214 Reissued 08/2017 This report is subject to renewal 07/2019. DIVISION: 09 00

More information

Joint Evaluation Report

Joint Evaluation Report 0 Joint Evaluation Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 ESR-1210 Reissued 09/2018 This report is subject to renewal 09/2020. DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES SECTION:

More information

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW VELOCITY X-U AND X-U 15 UNIVERSAL FASTENERS AND X-P CONCRETE FASTENERS

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW VELOCITY X-U AND X-U 15 UNIVERSAL FASTENERS AND X-P CONCRETE FASTENERS 0 ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org Most Widely Accepted and Trusted ESR-2269 Reissued 02/2017 Revised 11/2018 This report is subject to renewal 02/2019.

More information

Acoustic Treatment

Acoustic Treatment 1. Product Name Acousti-Matª Sound Control Systems Acousti-Matª I Acousti-Matª II Enkasonicª Acousti-Matª 3 Acousti-Matª LP/LPR Acousti-Matª SD 2. Manufacturer 920 Hamel Road P.O. Box 253 Hamel, MN 55340-9610

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2045 Reissued 01/2017 This report is subject to renewal 01/2019. DIVISION: 07 00

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER REPORT HOLDER: REDBUILT LLC EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER REPORT HOLDER: REDBUILT LLC EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 42 6587 (562) 699 054 www.icc es.org ESR 299 Reissued 01/2019 This report is subject to renewal 01/2021. DIVISION: 06 00 00

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: STARK TRUSS COMPANY, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: STARK TRUSS COMPANY, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 2 6587 (562) 699 05 www.icc es.org ESR 2919 Reissued 11/2017 This report is subject to renewal 11/2019. DIVISION: 06 00 00 WOOD,

More information