1 INSTALLATION MANUAL KOCH TECHNICAL SYSTEMS GROUP PRE-FAB ACOUSTICAL/THERMAL PANELS AND ENCLOSURES GEORGE KOCH SONS, LLC TECHNICAL SYSTEMS GROUP 10 South Eleventh Avenue Evansville, Indiana Revision Date 1/6/99
2 TABLE OF CONTENTS 1. INTRODUCTION 2. ORIENTATION TO THE KOCH PANELS 3. PREPARATION OF INSTALLATION AREA 4. ENCLOSURE ERECTION PROCEDURES 4.1. INSTALLING FLOOR CHANNEL 4.2. INSTALLING WALL PANELS 4.3. INSTALLING DOORS 4.4. INSTALLING INTERNAL SUPPORT STEEL 4.5. INSTALLING REMOVABLE PANELS 4.6. INSTALLING ROOF SUPPORT BEAM(S) 4.7. INSTALLING ROOF PANELS 4.8. INSTALLING ELECTRICAL WIRING AND CONDUIT 4.9. INSTALLING SLIDING DOORS INSTALLING STANDING SEAM ROOF PANELS 5. INSTALLING AIR CONDITIONERS 5.1. WINDOW STYLE UNITS 5.2. SPLIT UNITS 6. INSTALLING AIR INTAKE/EXHAUST SILENCERS 6.1. NON-POWERED UNITS 6.2. POWERED UNITS 7. INSTALLING ACCESSORIES 8. PAINT TOUCH UP
3 INTRODUCTION SECTION 1.0 This manual along with assembly drawings and/or material list should serve as a guide for quick and easy field erection of KOCH pre-fab acoustical/thermal panels. Should there be a conflict between information in this manual and the data shown on the drawings, the drawings will take precedence. Both the manual and the drawings should be reviewed and understood prior to commencing with installation. When receiving your shipment, please compare what you have received to the bill of material list on the drawing or the shipping list to ensure you have received your complete order. Damaged or missing items should be reported at once to minimize delay of installation. If you should have any questions before or during installation or have any other customer service needs, please call the Panel Products Group at
4 ORIENTATION TO THE KOCH PANELS SECTION 2.0 As you read and familiarize yourself with the following installation instructions you find the term gauge line used frequently. The following will describe and illustrate the term gauge line as it applies to KOCH pre-fab acoustical/thermal panels. From the above illustration, you will see that the gauge line is an imaginary line that is located one-half inch from either edge of the panel. Thus, the total width of any given panel is one inch wider than the designated gauge line. The exposed surface or effective surface when the panel is installed varies for each panel. In the case of a panel having one female edge and one male edge, this surface is equal to the gauge line, while in a double female edge the exposed surface is the full panel width or one inch more than the Gauge Line. The double male edged panels exposed surface is two inches less than the full panel width. Since a corner panel is basically a flat panel with a break, the above descriptions will apply equally for similar edge combinations. Should your enclosure be designed with windows, you will receive your panels already double-glazed with 1/4 thick glass of your specification.
5 PREPARATION OF INSTALLATION AREA SECTION 3.0 Area should be clean and free of all material that may interfere with the erection team. Check floor for flatness. If flatness in the area where floor channel will be installed is high or low in excess of 1/8, the area should be leveled with grout. If the enclosure is to be erected on a curb, verify curb dimensions with the enclosure drawing. Any irregularities should be corrected. Top of curb should be a minimum of 1/2 wider than the thickness of the panel to be installed. If curb is too narrow, add to the width.
6 ENCLOSURE ERECTION PROCEDURES SECTION 4.0 INSTALLING FLOOR CHANNEL SECTION 4.1 Layout the floor channel locations on area floor or curb and snap chalk lines for entire length of all walls. Use the overall outside enclosure dimensions located on the drawing. Check to assure that intersecting lines at all corners are square (90 apart). All floor channel corners should be mitered or coped in the field. Locate first length of floor channel along proper chalk line. On all enclosures, the floor channel will be a standard 120 long. Leave an open area in the floor channel for the doorway(s). For a 1 3/4 thk. acoustic door, the floor channel opening = 4 1/2 more than the door clear opening. For a full thickness (4 or 6 thk.) acoustic door, the floor channel opening = 11 1/4 more than the door clear opening. For an oven door, the floor channel opening = 12 1/4 more than the door clear opening. The floor channel has pre-punched holes for floor anchors. Once the floor channel is positioned in the proper place, use the pre-punched holes for templates and drill a 7/16 diameter by 2 long hole in the concrete floor or curb. If a 1/2 diameter anchor bolt is supplied, drill a 9/16 diameter by 2 1/2 long hole in the concrete. Caulk entire length of bottom of floor channel with two heavy beads of the supplied caulking. Make certain the floor channel is properly aligned and anchored securely in place. Using the drawing as a reference, mark the gauge line of the panels on the outside leg of the floor channel to act as a guide during panel installation. This will help to prevent over/under engagement of panels during installation. Caulk both the inside corners of floor channel heavily. Fill the floor channel with pre-cut strip insulation.
7 INSTALLING WALL PANELS SECTION 4.2 Start panel installation at a corner. Select the corner panel and caulk the female edge and install strip insulation in the male edge. Stand the panel upright inside the floor channel. Make sure the panel is plumb and secure with a temporary brace.
8 Should your enclosure be designed with built-up corners instead of corner panels, use the following procedures and illustration. Select the two panels that will form your corner. Caulk and install strip insulation as previously described. Stand one of the two corner panels up right inside the floor channel at the starting corner and secure with a temporary brace. Place the second corner panel inside the floor channel at 90 degrees to the first panel. With both panels now in place, make certain they are plumb and square. Proceed now to secure your corner by installing the inside and outside corner flashings. Prepare the Second wall panel by caulking inside the female edge and placing the pre-cut strip insulation inside the male edge. Stand the second panel upright inside the floor channel, tip it back, engage the bottom male corner then tip the panel forward to engage the panel full length. Following the procedure above, install additional panels. Check gauge line positions during installation. Periodically use a tape measure to check for over/under engagement of panels. Should your measurement indicate the dimension is shorter than specified, you may ease the installed panels apart until the proper dimension is reached or install additional panels with less engagement until the proper dimension is reached. See next page for more detail.
9
10 INSTALLING DOORS SECTION 4.3 Special attention should be given so that the frames remain plumb and square. Once the door leaf has been hung in the frame, some adjustment of the latches may be necessary. All acoustic doors should be installed progressively as if they are wall panels. On the 1 3/4 thk. acoustic door, it is best to leave the tie bar at the bottom of the door attached to keep the frame square. The acoustic door leafs can be easily removed from the doorframe to simplify installation. The full thickness acoustic doors (4 & 6 thk.) have a tie bar at the bottom. In most cases this should be removed. These doors have two anchor tabs on the inside bottom of the frame for anchoring to the floor.
11 The insulated door can be installed progressively during panel installation or after the wall panels are installed. The easiest method would be progressive installation. Should you choose to install last after the wall, the frame will need to be taken apart. See the illustration at the bottom of this page. The insulated door frame should be unbolted and separated into two halves. Each half should be installed respectively from the outside and inside of the already installed panel wall, then bolted back together.
12 INSTALLING INTERNAL SUPPORT STEEL SECTION 4.4 Internal columns are installed during installation of the panels and are swallowed inside the panel joint. Care must be taken to analyze the sequence of installation of the panel joints prior to beginning installation because the location of the internal steel may dictate which panels must be installed first. Internal columns may extend higher than the wall panels and have beams connected to the top, spanning across the enclosure. INSTALLING REMOVABLE PANELS SECTION 4.5 The removable panel system uses the existing floor channel at the bottom and a cap channel (with 2 1/2 legs) at the top. This cap channel will create a 1 1/2 open space above the removable panel. This will allow the panel to lift up into this space and then to be pulled outward from the bottom. If there is more than one removable panel, the panels will need to be installed in a certain order and removed in the reverse order of installation. These panels are shipped without the pull handles installed to prevent damage during shipping. The screw holes for the handles are pre-drilled in the panel and ready for attachment. See next page for more detail.
13
14 INSTALLING ROOF SUPPORT BEAM(S) SECTION 4.6 Place the 10-0 long saddle channel on top of the enclosure wall. The saddle channel will already have the two angle clips welded to it. Place the pre-coped beam between the clips and secure with the provided fasteners. Roof support beam(s) will span across the enclosure and act as a ledge for the roof panels to rest on.
15 INSTALLING ROOF PANELS SECTION 4.7 Roof panels will rest on the roof support beam or on the enclosure wall. Roof panels must be caulked, stuffed with insulation, and joined just like the wall panels. If the enclosure has an electrical conduit cavity, the 2 x 2 inside corner flashing should be installed prior to installing the roof panels to allow for additional support. After the roof panels are installed, check to make sure the walls are still plumb then secure the remaining flashing with sheet metal screws. All flashing is a standard 120 long. It may require field cutting to fit. As discussed in the next section, all electrical work should be completed prior to installing the outside corner flashing.
16 INSTALLING ELECTRICAL WIRING AND CONDUIT SECTION 4.8 All electrical conduit is supplied in 10 ft. lengths. All conduit parts necessary for complete installation are supplied by Koch. In most cases, the individual panels will be supplied with conduit and receptacle boxes already installed. The electrical wiring will require being pulled through the conduit by the installer. Use the supplied conduit connector parts to connect all conduit in the conduit cavity as shown in the following illustrations. 14 GA. wiring is the standard size supplied unless otherwise specified by the customer or when wiring for an air-conditioner unit. It is the customer s responsibility to insure all electrical work meets applicable national, state, and local codes.
17 INSTALLING SLIDING DOORS SECTION 4.9 The sliding doors can be installed after the enclosure walls and roof are complete. All the hardware needed to complete this installation is supplied by Koch. Before installing any sliding door hardware, the door opening in the enclosure should be finished with the supplied cap channel. You are now ready to install the structural angle to support the sliding door track. This angle should be located above the opening as shown on the drawing with the pre-drilled holes straddling the panel gauge line dimension locations. Mark the holes using the structural angle as a template. Drill 11/16 diameter holes completely through the thickness of the panel. Mount the structural angle on the exterior side of the wall. Mount the 1/4 thick back-up plate with pre-drilled holes on the interior side of the enclosure and secure with the provided fasteners. Next, mount the sliding door track brackets to the structural angle in the prepunched slots. Install the track into the track brackets. The sliding door leafs have pre-drilled and tapped holes ready for attaching the trolley trucks. Slide the door (trolley trucks) onto the sliding door track. Install the end caps onto the ends of the track to prevent the door from sliding off the track. Attach the stay roller to the floor as shown in the following illustrations or as shown on the drawings. Install the brush seals around the door opening, as noted on the drawing. Adjust doors as needed via the slot in the structural angle for horizontal adjustment or the jamb nut on the trolley truck for vertical adjustment.
18
19 INSTALLING STANDING SEAM ROOF PANELS SECTION 4.10 Install first standing seam panel at right edge of enclosure. The first standing seam panel may require trimming off the right side roll formed edge. Place the clip over the left side of the standing seam panel. Attach to the structure by either plug welding or with sheet metal screws. Place clips on approx. 4-0 centers. Place the next panel with the right side roll formed ridge over the top of the clip and previous standing seam panel. Continue this process until reaching the left side of the enclosure. The left edge of the last standing seam panel may need trimming off. Dimple each ridge every 24 with a button punch for a watertight seal.
20 INSTALLING AIR CONDITIONERS SECTION 5.0 WINDOW UNITS SECTION 5.1 Most window style units installed in Koch enclosures are installed in cutouts in the wall, not in a window opening. The wall cutout in most cases is pre-finished and ready for the A/C unit to be installed. Line the opening with some soft foam commonly used for window units prior to inserting the unit. Attach the supplied A/C support stand to the exterior side of the wall. Insert A/C unit. SPLIT DUCTLESS UNITS SECTION 5.2 The split style units consist of a fan coil unit and a condensing unit. The fan coil unit is installed on the inside of the enclosure on a specified panel, which has internal back-up steel for attaching the unit. Included in the packing box of this unit is a paper pattern used as a template and instructions for mounting this unit to the wall. A hole should be drilled or cut out for the hose connecting the fan coil and condensing units. The hole size and location are also specified on the paper pattern and instructions. The condensing unit is located on the exterior of the enclosure. It can be located on the floor, or if properly supported, on the enclosure roof. This cannot be done unless the roof is designed to withstand the load of the unit. INSTALLING AIR INTAKE/EXHAUST SILENCERS SECTION 6.0 NON-POWERED UNITS SECTION 6.1 This unit has a shoe box style lid that is attached with Tek screws. Remove this lid and attach the remaining unit in place over the supplied cutouts in the enclosure wall. Use the supplied Tek screws for attaching. Glue the supplied duct board in place to the enclosure wall. Cut out an opening in the duct board using the existing wall cutout as a template. Screw the silencer lid back on the silencer. Attach the supplied air vent grilles or bird screen covers to the openings.
21 POWERED UNITS SECTION 6.2 This unit is most commonly installed on the roof of the enclosure. Place the unit over the existing roof cutout. Secure the unit with the supplied 2 x 2 inside corner flashing. Connect the electrical wires to the enclosure electrical system.
22 INSTALLING ACCESSORIES SECTION 7.0
23 All supplied accessories (louvered vent covers, lights, receptacles, switches, etc.) are all standard type parts and are easily installed using standard construction methods. PAINT TOUCH UP SECTION 8.0 If your enclosure is painted Precision Tan, a Precision Tan Aerosol Can will be supplied for easy touch ups. If your enclosure is painted any color other than Precision Tan, a Preval Power Spray Unit and three different 1 QT. cans of Sherwin Williams Polane- T paint, catalyst, and reducer will be supplied. The paint, catalyst and reducer should be mixed together with a mix ratio of 64% paint, 11% catalyst, and 25% reducer. Pour the mixture into the Spray Unit bottle for paint touch ups.
INSTALLATION INSTRUCTION FOR ACOUSTIC ENCLOSURES
INSTALLATION INSTRUCTION FOR ACOUSTIC ENCLOSURES Planning Hints and Notes 1. Review the erection drawings prepared specifically for the job. 2. Bill of materials contains complete list of parts supplied
More informationDETAIL INSTRUCTION No. 1
BEFORE BEGINNING INSTALLATION, PLEASE READ THROUGH ALL INSTRUCTIONS. Uncrate shipment and check against packing list to insure all materials are included before beginning installation. If any discrepencies
More informationHOME SYSTEMS CONSTRUCTION PROCEDURE
HOME SYSTEMS WWW.QUICKBUILTHOMES.COM.AU CONSTRUCTION PROCEDURE INDEX - PARTS LIST PARTS LIST QBRC75(C) QBRM75C) QBSIPS75 QBRFSZ75C QBRFBC75C QBRF3030G QBRGSQC QBRFRC75C QBRFZEC QBRF4040C QBSACC75 QBFR7330WC
More informationINSTRUCTIONS AND GUIDELINES
INSTRUCTIONS AND GUIDELINES NOISEBLOCK TM MODULAR PANEL SYSTEMS ENCLOSURES & PRESSURIZED PLENUMS PLANNING HINTS & NOTES: 1. Review the Kinetics Noise Control submittal and installation drawings and bill
More informationPre-Installation See detail page for general notes concerning trim accessories, holes, fasteners, gaskets, caulking and support columns.
Pre-Installation See detail page for general notes concerning trim accessories, holes, fasteners, gaskets, caulking and support columns. Assembly of Acoustical Panels Instructions to be utilized with corresponding
More informationPATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge
Assembly Manual 8x5 PATENTS ARE PENDING Approximate Size 7980303 Storage Area Building Dimensions Exterior Dimensions Roof Edge to Roof Edge Interior Dimensions Wall to Wall Sq. Ft. Cu. Ft. Width Depth
More informationPATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge
Assembly Manual 8x9 PATENTS ARE PENDING Approximate Size 7640303 Storage Area Building Dimensions Exterior Dimensions Roof Edge to Roof Edge Interior Dimensions Wall to Wall Sq. Ft. Cu. Ft. Width Depth
More information6x5. Assembly Manual CAUTION. Sharp Edges PATENTS ARE PENDING. Building Dimensions. Approximate Size. Storage Area. Interior Dimensions
Assembly Manual 6x5 PATENTS ARE PENDING Building Dimensions Approximate Size Storage Area Exterior Dimensions Interior Dimensions Roof Edge to Roof Edge Wall to Wall Sq. Ft. Cu. Ft. Width Depth Height
More informationNortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1
16 May 2014 Page 1 PART 1 GENERAL 1.1 DESCRIPTION This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories
More informationSECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN
SECTION 08350 MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationPre-Fabricated Roof Curbs
Knock Down Curb Assembly Instructions These roof curb assembly instructions are to be used as general guidelines only. Included with shipment are as-built drawings for proper location of sections and channels.
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 092216 - NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION NON-STRUCTURAL METAL FRAMING
SECTION 09 22 16 PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories
More information1. Include plans, elevations, sections, details, and attachments to other work.
SECTION 102213- PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationSe incluyen las instrucciones en español
Page 1 of 16 Pittsburgh Corning Corporation Pittsburgh, PA 15239 1-800-624-2120 www.pittsburghcorning.com All trademarks and registered trademarks in this brochure are owned and protected by Pittsburgh
More informationA. Pipe Supports: ANSI B 31.1, Power Piping. B. Automatic Sprinkler Pipe Supports: Refer to Section
SECTION 15140 SUPPORTS, ANCHORS, AND SEALS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract including General and Supplementary Conditions, Division 1 Specification
More informationMETALWorkS. RH200 Custom Hook-on Panels. General Installation Instructions. Ceiling 1.0 GENERAL Site Conditions Product Description
Ceiling Systems Between us, ideas become reality METALWorkS General Installation Instructions RH200 Custom Hook-on Panels 1.0 GENERAL 1.1. Product Description RH200 system is a downward accessible, metal
More informationSECTION FIBERGLASS REINFORCED POLYESTER (FRP) DOORS AND ALUMINUM FRAMES
SECTION 081613 FIBERGLASS REINFORCED POLYESTER (FRP) DOORS AND ALUMINUM FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary
More informationSECTION NON-STRUCTURAL METAL FRAMING
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 22 16 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable
More informationHOTEL SPECIFICATION SECTION 08100
Part 1 General HOTEL SPECIFICATION SECTION 08100 1.01 Work Included A. The work under this section shall include the furnishing of all items shown on the drawings and as specified including, but not limited
More informationSUBMITTAL PACKAGE CUSTOM HOLLOW METAL DOORS, FRAMES AND WINDOWS
Box 1101, 140 Coal St. Raton, NM 87740 Phone 575-445-2756 Fax: 575-445-2804 SUBMITTAL PACKAGE CUSTOM HOLLOW METAL DOORS, FRAMES AND WINDOWS DATE: PROJECT: LOCATION: CONTRACTOR: QUANITITY: DOORS: FRAMES:
More informationPre-Fabricated Roof Curbs
TC-1, TC-2, TC-3, TC-5 Table of Contents General Information 4-5 Specifications 6-9 Assembly Instructions 10-16 Pitch Information 17 Submittal 18-21 54 years of excellence... www.thybar.com 3 Insulated
More informationH50. DYNAMIC BARRIER Bench Fume Hood. Fume Hoods. Installation Instructions. 48"- 60"- 72"- 96" long
Installation Instructions Supreme Air DYNAMIC BARRIER Bench Fume Hood H50 S T Y L E Fume Hoods 48"- 60"- 72"- 96" long Publication No. IIH50-SA 06/01 Part Number: IMAN-H50 Kewaunee Scientific Corporation
More informationDIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING
DIVISION 5 METALS SECTION 05 40 00 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationThermaSteel Corporation ASSEMBLY MANUAL
ThermaSteel Corporation ASSEMBLY MANUAL TABLE OF CONTENTS 1- INTRODUCTION 1.1 THERMASTEEL TM WALL PANELS 1.2 Drawing and Element Numbers 2- ASSEMBLY 2.1 Sequence of Assembly 2.2 Preparation of Foundation
More informationRytec Corporation One Cedar Parkway Jackson, WI GO-RYTEC (262)
Rytec Corporation One Cedar Parkway Jackson, WI 53037 1-888-GO-RYTEC (262) 677-9046 WWW.Rytecdoors.com Pharma-Swing Model Number PSW12002 SECTION 08300 HIGH PERFORMANCE FIBERGLASS SWING DOOR PAIR PART
More informationTABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers
version 2.5 updated as of 08.04.2017 2 TABLE OF CONTENTS 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers 2.0 ASSEMBLY 2.1 Sequence of Assembly 2.2 Preparation
More informationHome Depot Page 1 of 5 HDPB Humacao, PR 10/19/09
PART 1 - GENERAL 1.01 SUMMARY A. Types of cold-formed metal framing units include the following: 1. C-shaped steel studs B. Related work specified elsewhere includes but may not be limited to: 1. Section
More informationContainer Installation Guide
Container Insulation Container Installation Guide Panels and Inserts The InSoFast CX Container panel and the Inserts are designed to fit most shipping containers. Containers have three types of corrugations:
More informationGuardian Wall Panel Installation Manual
Guardian 275 4 Wall Panel Installation Manual Guardian 275 4 Wall Panel Installation Manual This instructional manual provides General Installation Instruction. Installers should refer to the "as-built"
More informationIMPORTANT: Levelness of the walk-in floor is critical. If the floor is not level, vertical panels cannot be aligned properly.
Floor panels INSTALLATION This section is applicable only if your walk-in has a floor. If not, proceed with next section. These are probably the most important panels you will install. To install the floor
More informationHOLLOW METAL DOORS AND FRAMES SECTION HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL
13686.00 HOLLOW METAL DOORS AND FRAMES 081113-1 SECTION 081113 - HOLLOW METAL DOORS AND FRAMES 1.1 RELATED DOCUMENTS: PART 1 - GENERAL A. Drawings and general provisions of Contract, including General
More informationPS 3000 Installation Manual Step-By-Step Procedures C.9. DOOR AND WINDOW OPENINGS C.9.1 PREPARE IN ADVANCE. C.9.2 VBUCK CONSTRUCTION.
C.9. DOOR AND WINDOW OPENINGS Openings for doors and windows are formed with bucks, or frames, which are constructed to the rough opening dimensions required for the doors and windows to be installed.
More informationThe Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage
The Ashland Project Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The garage and bedroom extend from the front of this three bedroom home, drawing you visually into the entryway. Brick and stucco
More informationCOLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100
COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100 Part 1 General 1.01 Work Included A. The work under this section shall include the furnishing of all items shown on the drawings and as specified,
More informationUNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:
SECTION 092216 - COLD FORMED STEEL FRAMING - NON-STRUCTURAL (CFSF-NS) PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 ACTION
More informationH07 H09. BENCH FUME HOOD with Combination Sash. Fume Hoods. Installation Instructions. 48"- 60"- 72"- 96" long
Installation Instructions Supreme Air BENCH FUME HOOD with Combination Sash H07 H09 S T Y L E Fume Hoods 48"- 60"- 72"- 96" long Publication No. IIH07-SA 07/06 Part Number: IMAN-H07 FUME HOOD END PANEL
More informationMASONRY ANCHORS AND CONNECTORS May 6, 2014
Page - 1 This section includes specification text to assist in describing a variety of masonry anchors, connectors, and accessories intended for masonry construction. This document contains prepared master
More informationSERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651
SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651 PART 1 GENERAL 1.1 DESCRIPTION A. Work Included: 1. Furnish all labor and materials to complete the fabrication of detention windows as
More informationNatureScape. 3 Thermally Broken 2 Non-thermal
NatureScape 3 Thermally Broken 2 Non-thermal REASONS TO CONSIDER PREFABRICATED: Pre-designed, pre-engineered and pre-inspected, the NatureScape enclosure guarantees that the room will be delivered and
More informationMetal Door Frames & Meter Boxes
Metal s & Meter Boxes April 2018 Metroll s Metroll manufactures a comprehensive range of door frames from top quality materials designed to suit various applications. This brochure contains details and
More informationSECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.
SECTION 06110 WOOD FRAMING PART 1 GENERAL 1.1 SUMMARY A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. B. Products Installed But Not Supplied
More informationPittsburgh Corning ProVantage Glass Block Installation System Assembly Instructions
Pittsburgh Corning ProVantage Glass Block Installation System Assembly Instructions Introduction: The ProVantage Glass Block Installation System is the easiest way to install Pittsburgh Corning Premiere
More informationOmniFlex 300 Plus Installation Instructions
OmniFlex 300 Plus Installation Instructions IMPORTANT PortaFab advises a thorough reading of these instructions before beginning installation. INTRODUCTION Instructions should be read thoroughly and cross-referenced
More informationSEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets
SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets Seismic Frame Two-Post Rack Page 11-3 Seismic Protection Products - Racks Page 11-6 Seismic Protection Products - Runway Page 11-8 Seismic
More informationN-SERIES: NTH2700 SPECIFICATIONS Tubular Composite Top Hung Sliding Door System
Version 5.22.13 N-SERIES: NTH2700 SPECIFICATIONS Tubular Composite Top Hung Sliding Door System OPTIONS ARE LISTED IN BOLD, PLEASE MODIFY THESE AREAS AS NEEDED BASED ON YOUR PROJECT CONSULT MANUFACTURER
More informationSKATEWHEEL FLOW RACK
SKATEWHEEL FLOW RACK 2 ASSEMBLY INSTRUCTIONS: Steel King Industries recommends that this product be assembled only by qualified personnel, experienced in assembly of storage racks, and knowledgeable of
More informationN-SERIES: NTH3500 SPECIFICATIONS Hollow Metal Sliding Door System
Version 5.22.13 N-SERIES: NTH3500 SPECIFICATIONS Hollow Metal Sliding Door System OPTIONS ARE LISTED IN BOLD, PLEASE MODIFY THESE AREAS AS NEEDED BASED ON YOUR PROJECT CONSULT MANUFACTURER FOR ADDITONAL
More information1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.
SECTION 05500- METAL FABRICATIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION HOLLOW METALWORK. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.
SECTION 081113 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting
More informationH D P SOLID PHENOLIC FLOOR BRACED COMPARTMENTS SECTION FB TOILET PARTITIONS
3501 East La Palma Avenue - Anaheim, California 92806 PART 1 GENERAL Ph: 714-666-0108 and 714-666-0109 Fax: 714-666-0110 www.weisrobart.com H D P SOLID PHENOLIC FLOOR BRACED COMPARTMENTS 1.1 RELATED DOCUMENTS:
More informationSECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS
SECTION 08110 - STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General, Supplementary, and Special Conditions and Division 1 Specification
More information1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits.
SECTION 09 2216 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and
More informationNEW ILLUMINATED LED SIGNAGE PAINTED STOREFRONT W/ VINYL GRAPHIC AND NEW LED SIGNAGE PAINT FINISHES (PROVIDE (2) COATS FOR ALL PAINTING) PT-1
MTA RR APPARATUS NEW ILLUMINATED LED SIGNAGE LIGHTWEIGHT REMOVABLE ALUMINUM PANEL FENCE 88 NORTH AVE CDR JOB NO. 60 NORTH AVE NORTH AVE CURRENT VIEW OF 88 NORTH AVENUE PROPOSED FACADE AT 88 NORTH AVENUE
More informationInstructions for the use of the Link 4 Pallet Rack Lifter (PRL) model 5000
Instructions for the use of the Link 4 Pallet Rack Lifter (PRL) model 5000 (How to move your pallet racking using the Link 4 Pallet Rack Lifter) This process is for a typical rack move and reset. Each
More informationL-SERIES: LTH3900 SPECIFICATIONS Stainless Steel Hollow Metal Sliding Fire Door System
Version 5.22.13 L-SERIES: LTH3900 SPECIFICATIONS Stainless Steel Hollow Metal Sliding Fire Door System OPTIONS ARE LISTED IN BOLD, PLEASE MODIFY THESE AREAS AS NEEDED BASED ON YOUR PROJECT CONSULT MANUFACTURER
More informationK. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.
DIVISION 05 METALS 05 12 00 STRUCTURAL STEEL FRAMING PART 1 GENERAL 1.1 SECTION INCLUDES A. Structural steel framing members, support members. 1.2 RELATED REQUIREMENTS A. Section 05 50 00 - Metal Fabrications:
More informationThe fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general specifications:
Query No.1 ; we need more specs. about fire resistant doors Answer to Query No. 1: The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general
More informationGenesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions
Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions Thank you for purchasing the Genesis Dura-Max Brick Panel system for your project. The system allows you to have the look
More informationInstallation Guidelines for all Quaker products with nail fins New construction nail fin installation with a drainable weather resistant barrier.
www.quakerwindows.com www.quakercommercialwindows.com PO Box 128 504 Highway 63 South Freeburg, MO 65035 800-347-0438 573-469-4151 (fax) Installation Guidelines for all Quaker products with nail fins New
More informationPHYSICAL BARRIERS MACHINE GUARDS ROBOTIC WORK CELLS PERIMETER OR AREAS GUARDS PHYSICAL BARRIERS
PHYSICAL BARRIERS MACHINE GUARDS ROBOTIC WORK CELLS PERIMETER OR AREAS GUARDS PHYSICAL BARRIERS Quick-Ship Ships in 48 Hours The 6-2 Guard System Our barriers are a reliable, versatile, and economical
More informationSK2000 Boltless Pallet Rack Installation and Assembly Manual
SK2000 Boltless Pallet Rack Installation and Assembly Manual Steel King Industries, Inc. 2700 Chamber St Stevens Pont, WI 54481 (800) 826 0203 www.steelking.com info@steelking.com ASSEMBLY INSTRUCTIONS:
More informationSECTION NON--STRUCTURAL METAL FRAMING
The Collective Voice of America s Steel Framing Industry The Steel Framing Industry Association (SFIA) is dedicated to expanding the market for cold-formed steel in construction through programs and initiatives
More informationRevision Date: April 01, Premier Vinyl Enclosure
Premier Vinyl Enclosure www.urbanindustries.com 53 Urban Industries, Inc. 2008 Tools The following tools are recommended for the installation of the Premier Vinyl Enclosure and roof. 1 2 Level 1 4 Level
More informationINSTALLATION CHECKLIST 2 ND EDITION. Fox Blocks Abbott Drive Omaha, NE
Fox Blocks INSTALLATION CHECKLIST ND EDITION Fox Blocks Installation Checklist: ND Edition 6110 Abbott Drive Omaha, NE 6110-69-6 WWW.FOXBLOCKS.COM INSTALLATION CHECKLISTS The Checklists on the following
More informationA-ONE Insulated Forms Installation Manual
A-ONE Insulated Forms Installation Manual Rockford, MN www.aoneform.com www.diversifoam.com info@diversifoam.com A-ONE Manual 180426.docx Disclaimer Notice The information in the A-ONE Insulated Forms
More informationSECTION ELECTRIC FOUR FOLD DOORS MODEL 46 FLAT SHEETED
SECTION 08350 ELECTRIC FOUR FOLD DOORS MODEL 46 FLAT SHEETED PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
More informationAMBICO Limited Section and DETENTION STEEL DOOR AND FRAME ASSEMBLIES Page 1
Page 1 This section includes AMBICO Detention Steel Door and Frame assemblies that can be fire rated or non-rated. This section relies on both the Canadian Steel Door Manufacturers Association (CSDMA.org)
More informationSoundmaster & Modernfold TECHNICAL DATA
This specification along with product information and model details can be downloaded from www.modernfold.com SPECIFICATION - SECTION 08 35 13 ACCORDION FOLDING DOORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS
More informationHDPE SOLID POLYMER-PLASTIC FLOOR BRACED COMPARTMENTS SECTION FB WEIS/POLY TOILET PARTITIONS
3501 East La Palma Avenue - Anaheim, California 92806 Ph: 714-666-0108 and 714-666-0109 Fax: 714-666-0110 www.weisrobart.com PART 1 GENERAL HDPE SOLID POLYMER-PLASTIC FLOOR BRACED COMPARTMENTS SECTION
More informationSERIES 487 CENTER GLAZED SLIDING DOOR WITH 1-1/2" TRIM
INSTALLATION INSTRUCTIONS SERIES 487 CENTER GLAZED SLIDING DOOR WITH 1-1/2" TRIM Phone: (800) 421-6144 Fax: (866) 921-0531 crlaurence.com usalum.com crl-arch.com 11M0200 GENERAL INSTALLATION NOTES Recommended
More informationSECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping
SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes pipe and equipment supports, hangers, anchors, bases sleeves and the sealing of
More informationKS SERIES - VERTICAL INSTALLATION
CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV
More informationSECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.
SECTION 05520 HANDRAILS AND RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES A. Welded stainless steel railing systems. 1.2 RELATED SECTIONS A. Section 03300 - Cast-In-Place Concrete; coordination with substrate.
More information5045 Orbitor Dr., Building 8, Suite 200, Mississauga, ON L4W 4Y4 Phone: (905)
TYPICAL INSTALLATION PROCEDURES FOR ACOUSTIC ENCLOSURES VG-QT-1669 Rev. 0 Page 1 of 16 GENERAL INFORMATION VG Engineering Noise Control Enclosures are custom configured to suit customer requirements. Enclosures
More informationSECTION GYPSUM BOARD & SHEATHING SYSTEMS
PART 1!GENERAL! 1.01! SECTION INCLUDES SECTION 09260 GYPSUM BOARD & SHEATHING SYSTEMS! Metal stud wall framing. Metal channel ceiling framing.! Gypsum board.! Sheathing.! Taped and sanded joint treatment.!
More informationBefore You Get Started, You Will Need
LiteForm forming components should only be assembled by workers who have been properly trained. It is the installer s responsibility to make sure that training is done before construction begins. Serious
More informationSIEMENS. Instructions. Outdoor Metal Clad Switchgear. Installation Assembly OGM&SGM SG kV and 15kV. www. ElectricalPartManuals.
SIEMENS Outdoor Metal Clad Switchgear 5kV and 15kV Instructions Installation Assembly OGM&SGM SG 3258-00 THIS EQUIPMENT CONTAINS HAZARDOUS VOLTAGES. SEVERE PERSONAL INJURY OR PROPERTY DAMAGE CAN RESULT
More informationTrench Duct Class Catalog 5230CT9601R10/08
5230CT9601R10/08 2009 Class 5230 CONTENTS Application.................................................5 Unassembled Trench Duct Components.........................6 Factory Assembled Trench Duct..............................11
More informationSECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT
SECTION 23 05 29 HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes pipe and equipment supports, hangers, anchors, bases sleeves and the sealing of work
More informationSECTION GYPSUM BOARD ASSEMBLIES
SECTION 09 21 16 GYPSUM BOARD ASSEMBLIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Metal stud wall and ceiling framing, 20 gauge. B. Metal channel suspended ceiling framing. C. Gypsum board. D. Gypsum sheathing.
More informationThe motor shall be high-starting torque, ball bearing, rated at 460 V, 3 phase
MODEL 41 ELECTRIC FOUR FOLD DOORS Guide Specification Template INSTRUCTIONS FOR USE EPD has provided this PDF guide template to assist in your development of an accurate document for use in specifying
More informationStudent Services & Classroom Addition
SECTION 055113 - METAL PAN STAIRS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationProduct Description. Standard Sizes and Hardware Locations
F06 1 Product Description A-Series is Fleming s standard adjustable jamb depth 16 gage paintable galvanneal steel, knocked-down, drywall profile, punch mitered frame, used in drywall or existing masonry
More informationSECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 [08 33 13] COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Metal Counter
More informationYCW 250 I-Beam Curtain Wall System Installation Manual
Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS INSTALLATION NOTES..................................... Page ii PARTS DESCRIPTION Framing
More informationHANDSET WALL FORM. Handset Wall Form. Quick Assembly - can be built using only a hammer. Reduced weight increases productivity
HANDSET WALL FORM Quick Assembly - can be built using only a hammer Reduced weight increases productivity Unsurpassed flexibility in design and availability of panels for a wide variety of applications
More informationMARLIN WINDOWS, INC 3500 HC SERIES 3 3 8" SLIDING WINDOW PAGE 1
PAGE 1 SPECIFICATIONS GENERAL Sliding windows shall be Marlin series #3500-HC (thermally improved) as manufactured by Marlin windows, and shall conform to ANSI/AAMA 101-88 HS-HC40. Series #3500 shall have
More informationZurn Z886. 6" Perma-Trench. Installation Instructions
Zurn Z886 6" Perma-Trench Installation Instructions Z886 Accessories 6" [152mm] Wide Trench Drain System Below are the components of the Z886 trench drain typical to an installation. Check your order to
More informationAMBICO Limited 7\2018 Section and OVERSIZED METAL DOORS AND FRAMES Page 1
Page 1 This section includes Oversize Steel Doors and Frames and relies on the Canadian Steel Door Manufacturers Association (CSDMA.org) industry standard, as well as on the Hollow Metal Manufacturers
More informationCONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT
CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT SPECIFICATION EO-1124 REVISION 3 November 2013 EFFECTIVE DATE November 11,
More informationModular Buildings. Installation Manual
Modular Buildings Installation Manual 1. Introduction 2 2. Marking Installation Area 2 3. Speed-Lok Operation 2 4. 'Z' Base Trim 3 5. Less Floor Walk-Ins 3 6. Floor Panel Installation 4 7. With-Floor Installation
More informationBEARING METAL STUD FRAMING
L-1 Section 05410 Long Form Specification LOAD BEARING METAL STUD FRAMING This section includes axially loaded steel studs, with unique slotted top channels, usually of 0.91, 1.2 and 1.5 mm (16, 18, or
More informationC.R. LAURENCE CO., INC. Intelli-Track SPS. Phase One - Installation Instructions
Tools and Supplies: C.R. LAURENCE CO., INC. Intelli-Track SPS Phase One - Installation Instructions Ratchet Wrench with 4" Extension 9/16" Open-End Wrench (two required for suspension mounting) 9/16" Hex
More information1. Seismic Loads: Reference structural drawings.
SECTION 102213 ~WIRE MESH PARTITIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general prov1s1ons of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents.
SECTION 06 1100 WOOD FRAMING PART 1 - GENERAL 1.1 SUMMARY A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents. B. Products Installed But
More informationSUPERIOR ROOF SYSTEMS
SUPERIOR ROOF SYSTEMS S U P E R I O R M E T A L P R O D U C T S C O M P A N Y, I N C. Installation instructions & parts list DESCRIPTION CATALOG # 1. Tek Screw #14 x 4 7725 2. Dow 999-A Silicone 7679 3.
More informationGlass Block Installation System. simple, quick, safe, mortar-free. Glass Block Installation System
Glass Block Installation System VetroQUICK Glass Block Installation System simple, quick, safe, mortar-free FOR USE WITH SEVES PEGASUS AND MENDINI SERIES GLASS BLOCK ONLY. SEVES GLASS BLOCK SEVESGLASSBLOCKDESIGNS.COM
More informationPV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual
PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual Series 200 UL Introduction Series 200 UL Introduction SnapNrack Series
More informationBanyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL
SECTION 09511 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More information