DESIGN DOORS TEL:

Size: px
Start display at page:

Download "DESIGN DOORS TEL:"

Transcription

1 DESIGN DOORS Doors are an integral part of your home and it s essential to find the right ones to fit your design. Our Design range offers a contemporary feel for maximum light, a spacious feel and optimum efficiency.

2 DESIGN DOORS PRODUCT SELECTOR The Westcoast system offers a choice of hinged single leaf and double doors to suite with the open out range of windows and fixed lights. The doors are generally multipoint espagnolette secured and can be supplied with a variety of locking devices suitable for controlled access such as to private terraces and balconies or for emergency escape purposes. There is also a choice of single leaf and bi-parting sliding doors with a range of suited fixed lights for assembling glazed screens. SLIDING OPEN OUT OPEN IN U value db SBD Sliding Doors Open Out Doors Open In Doors U-Value W / m 2 K Acoustic Attenuation Secured by Design Internal Cleaning Internal Maintenance 30 Minute Fire Rating FDG/FDGD Open Out Balcony/ Terrace Door FDGL/FDGDL/ FDGLX Open Out Access Door SDA (SINGLE LEAF SLIDING) Lift & Slide Door SDC (BI-PARTING) Lift & Slide Door U values are calculated in accordance with EN ISO Table declares 48mm triple glazed values. All Westcoast windows are manufactured to specification. The product selector summarises tested and calculated performance achievable by category and may vary according to frame size, glazing specification and other factors. For specific performance data, please consult Westcoast Windows technical support department.

3 FDG/FDGD OPEN OUT BALCONY/TERRACE DOOR DESIGN APPLICATION For residential access purposes to ground floor terrace or upper floor level balcony locations where doors are to be secured principally from within the building. FUNCTION Single leaf doors (FDG) are secured by a concealed multipoint locking espagnolette bolt mechanism incorporating an integral handle operated friction stay with a variable hold open position up to either 90 or 165. In the case of pairs of doors (FDGD) the slave leaf is secured with flush bolts as standard or for enhanced security with espagnolette operation. SBD U dB HEAD IRONMONGERY Butt Hinges: Satin anodised finish with integral hinge protection. Espagnolette: Concealed multipoint locking wedge bolts or lever/ latch operation. Handle: Satin anodised lever handles and cylinder locks internally and externally. A wide range of optional ironmongery items and threshold details are available, please contact us for further information. LOW PROFILE THRESHOLD 2600 H HINGE JAMB W = Min/Max sizes (Single Door) = Min/Max sizes (DoubleDoor) Note: Size limits also depend on the weight of the glazing. For further information please contact our Technical Department. Clear opening = frame width less 173mm (single leaf).

4 THE SYSTEM STANDARDS CONSTRUCTION Composite construction combining extruded aluminium alloy profiles to EN AW 6060-T6 and close grained, laminated North European Redwood, durability Class 3 as defined in BS EN 350. Other timber species can be specified. Timber frame and casement sections are precision machined and assembled with pinned and glued comb joints. Mullions and transoms are assembled with mortice and tenon joints. External aluminium frame profiles are assembled with sealed mitred joints by means of crimped angle cleats, bonded with PIB tape and mechanically fixed with stainless steel pins to internal timber members. Windows are fully weatherstripped with EPDM or silicone slot seals. MANUFACTURE All windows and doors are purpose made to specification in accordance with BS 644 : 2009 and EN : APPEARANCE Aluminium profiles are chemically pre-treated and powder coated in any standard RAL colour in accordance with BS 6496 : Standard gloss level 75% +/- 5%. Other gloss levels can be specified. Timber is fully factory finished with a two or three coat spray applied water based clear lacquer gloss level 35%, paint to NCS/ RAL specification gloss level 40% or a wide range of standard stain finishes gloss level 35%. GLASS AND GLAZING Windows and doors are factory double or triple glazed to specification in accordance with BS 6262 : 1982 with 28mm, 36mm or 48mm dual sealed units constructed to EN : 2002 and safety glazed where applicable in accordance with BS 6206 : 1981 and Building Regulation 2000 Approved Document N. Products are typically externally bead glazed employing a drained and ventilated glazing system with sealed units incorporating warm edge composite super spacers and argon gas filling as standard. Sealed units are supported on setting blocks and dry glazed with EPDM gaskets. All commercially available high performance glass types can be specified to meet particular requirements for thermal insulation, acoustic attenuation, solar control, safety, security and fire protection. PERFORMANCE All Westcoast products can be considered as genuinely high performance but frame size, glazing and other factors can, however, directly affect performance levels. Westcoast technical support staff should be consulted if particular data is required or for advice on how to achieve the most cost effective solution for specific performance targets. WEATHERTIGHTNESS Products comply with the following minimum performance standards when tested in accordance with: EN 1026 : 2000 (air permeability) EN 1027 : 2000 (watertightness) EN : 2000 (wind resistance) Air Permeability: 600 Pa (Class 4) In accordance with EN : 2000 Watertightness: 900 Pa (Class E900) In accordance with EN : 2000 Wind Resistance: 2000 Pa (Class A5) In accordance with EN : 2000 Exposure Category : 2000 In accordance with BS 6375 : Part 1 : 2009 THERMAL INSULATION Products can be glazed to provide whole window U values ranging from 1.4Wm 2 K to less than 0.8Wm 2 K in accordance with EN ISO : ACOUSTIC ATTENUATION Double and triple glazed products can be specified to achieve tested sound reductions in a range from 31 to 48dB(Rw) in accordance with EN ISO : SECURED BY DESIGN All principle products have been tested to comply with PAS 24: FIRE RESISTANCE Fixed and opening lights are classified EI45 and EI 2 45 in accordance with EN : A1 : 2009 when tested to EN : 1999 and EN : 2014 respectively. TESTING A continuous programme of internal and 3rd party independent testing ensures that Westcoast products remain at the very forefront of fenestration technology. INSTALLATION Westcoast windows and doors are supplied to site fully factory finished and glazed for installation into prepared openings. A comprehensive design and installation service is offered. MAINTENANCE Maintenance is limited to periodic washing of external aluminium and glass surfaces with water containing a mild detergent. Internal timber should be cleaned with a damp cloth or polished. Ironmongery items are made from corrosion resistant materials and require only annual inspection and lubrication of appropriate moving parts. Since our policy is one of continuous improvement, we reserve the right to change without prior notice the specifications and methods of construction described in this document. No responsibility whatsoever can be accepted for any errors or omissions in, or misrepresentations of the contents. Details shown are for guidance purposes only and may vary according to circumstances. For specific information, refer to Westcoast Windows Systems Limited. Copyright reserved.

5 FDGL/FDGDL/FDGLX OPEN OUT ACCESS DOOR DESIGN APPLICATION For residential/light commercial access where doors are to be secured both internally and externally or for emergency exit purposes. FUNCTION Single leaf doors (FDGL) and the leading leaf of pairs of doors (FDGDL) are secured by a concealed multipoint locking lever/latch espagnolette bolt mechanism with cylinder locks and fitted with lever/lever handles. Emergency exit doors (FDGLX) are secured and operated by surface mounted panic escape gear. SBD U dB HEAD IRONMONGERY Butt Hinges: Satin anodised finish with integral hinge protection. Espagnolette: Concealed multipoint locking lever/latch espagnolette. Handle: Satin anodised lever handles and cylinder locks internally and externally. A wide range of optional ironmongery items are available, please contact us for further information. In the case of emergency exit operation, doors are fitted as standard with surface mounted panic escape gear. LOW PROFILE THRESHOLD 2600 H HINGE JAMB W = Min/Max sizes (Single Door) = Min/Max sizes (DoubleDoor) Note: Size limits also depend on the weight of the glazing. For further information please contact our Technical Department. Clear opening = frame width less 173mm (single leaf).

6 THE SYSTEM STANDARDS CONSTRUCTION Composite construction combining extruded aluminium alloy profiles to EN AW 6060-T6 and close grained, laminated North European Redwood, durability Class 3 as defined in BS EN 350. Other timber species can be specified. Timber frame and casement sections are precision machined and assembled with pinned and glued comb joints. Mullions and transoms are assembled with mortice and tenon joints. External aluminium frame profiles are assembled with sealed mitred joints by means of crimped angle cleats, bonded with PIB tape and mechanically fixed with stainless steel pins to internal timber members. Windows are fully weatherstripped with EPDM or silicone slot seals. MANUFACTURE All windows and doors are purpose made to specification in accordance with BS 644 : 2009 and EN : APPEARANCE Aluminium profiles are chemically pre-treated and powder coated in any standard RAL colour in accordance with BS 6496 : Standard gloss level 75% +/- 5%. Other gloss levels can be specified. Timber is fully factory finished with a two or three coat spray applied water based clear lacquer gloss level 35%, paint to NCS/ RAL specification gloss level 40% or a wide range of standard stain finishes gloss level 35%. GLASS AND GLAZING Windows and doors are factory double or triple glazed to specification in accordance with BS 6262 : 1982 with 28mm, 36mm or 48mm dual sealed units constructed to EN : 2002 and safety glazed where applicable in accordance with BS 6206 : 1981 and Building Regulation 2000 Approved Document N. Products are typically externally bead glazed employing a drained and ventilated glazing system with sealed units incorporating warm edge composite super spacers and argon gas filling as standard. Sealed units are supported on setting blocks and dry glazed with EPDM gaskets. All commercially available high performance glass types can be specified to meet particular requirements for thermal insulation, acoustic attenuation, solar control, safety, security and fire protection. PERFORMANCE All Westcoast products can be considered as genuinely high performance but frame size, glazing and other factors can, however, directly affect performance levels. Westcoast technical support staff should be consulted if particular data is required or for advice on how to achieve the most cost effective solution for specific performance targets. WEATHERTIGHTNESS Products comply with the following minimum performance standards when tested in accordance with: EN 1026 : 2000 (air permeability) EN 1027 : 2000 (watertightness) EN : 2000 (wind resistance) Air Permeability: 600 Pa (Class 4) In accordance with EN : 2000 Watertightness: 900 Pa (Class E900) In accordance with EN : 2000 Wind Resistance: 2000 Pa (Class A5) In accordance with EN : 2000 Exposure Category : 2000 In accordance with BS 6375 : Part 1 : 2009 THERMAL INSULATION Products can be glazed to provide whole window U values ranging from 1.4Wm 2 K to less than 0.8Wm 2 K in accordance with EN ISO : ACOUSTIC ATTENUATION Double and triple glazed products can be specified to achieve tested sound reductions in a range from 31 to 48dB(Rw) in accordance with EN ISO : SECURED BY DESIGN All principle products have been tested to comply with PAS 24: FIRE RESISTANCE Fixed and opening lights are classified EI45 and EI 2 45 in accordance with EN : A1 : 2009 when tested to EN : 1999 and EN : 2014 respectively. TESTING A continuous programme of internal and 3rd party independent testing ensures that Westcoast products remain at the very forefront of fenestration technology. INSTALLATION Westcoast windows and doors are supplied to site fully factory finished and glazed for installation into prepared openings. A comprehensive design and installation service is offered. MAINTENANCE Maintenance is limited to periodic washing of external aluminium and glass surfaces with water containing a mild detergent. Internal timber should be cleaned with a damp cloth or polished. Ironmongery items are made from corrosion resistant materials and require only annual inspection and lubrication of appropriate moving parts. Since our policy is one of continuous improvement, we reserve the right to change without prior notice the specifications and methods of construction described in this document. No responsibility whatsoever can be accepted for any errors or omissions in, or misrepresentations of the contents. Details shown are for guidance purposes only and may vary according to circumstances. For specific information, refer to Westcoast Windows Systems Limited. Copyright reserved.

7 S DA LIFT & SLIDE DOOR DESIGN APPLICATION For residential access purposes at ground floor terrace or upper floor level balcony locations where large openings are required and doors are to be secured principally from within the building. FUNCTION A simple rotation of the operating handle disengages the sliding leaf from the multipoint locking bolts and at the same time, the mechanism allows the leaf to effortlessly slide into the open position. SBD U dB SLIDING HEAD IRONMONGERY Operating Gear: Lift and slide mechanism with handle engagement device. Internal Handle: Satin anodised finish lift and slide handle with cylinder lock. External Finger Pull: Satin anodised. A wide range of optional ironmongery items are available, please contact us for further information. SLIDING THRESHOLD 2600 H SLIDING JAMB W = Min/Max sizes Note: Size limits also depend on the weight of the glazing. For further information please contact our Technical Department.

8 THE SYSTEM STANDARDS CONSTRUCTION Composite construction combining extruded aluminium alloy profiles to EN AW 6060-T6 and close grained, laminated North European Redwood, durability Class 3 as defined in BS EN 350. Other timber species can be specified. Timber frame and casement sections are precision machined and assembled with pinned and glued comb joints. Mullions and transoms are assembled with mortice and tenon joints. External aluminium frame profiles are assembled with sealed mitred joints by means of crimped angle cleats, bonded with PIB tape and mechanically fixed with stainless steel pins to internal timber members. Windows are fully weatherstripped with EPDM or silicone slot seals. MANUFACTURE All windows and doors are purpose made to specification in accordance with BS 644 : 2009 and EN : APPEARANCE Aluminium profiles are chemically pre-treated and powder coated in any standard RAL colour in accordance with BS 6496 : Standard gloss level 75% +/- 5%. Other gloss levels can be specified. Timber is fully factory finished with a two or three coat spray applied water based clear lacquer gloss level 35%, paint to NCS/ RAL specification gloss level 40% or a wide range of standard stain finishes gloss level 35%. GLASS AND GLAZING Windows and doors are factory double or triple glazed to specification in accordance with BS 6262 : 1982 with 28mm, 36mm or 48mm dual sealed units constructed to EN : 2002 and safety glazed where applicable in accordance with BS 6206 : 1981 and Building Regulation 2000 Approved Document N. Products are typically externally bead glazed employing a drained and ventilated glazing system with sealed units incorporating warm edge composite super spacers and argon gas filling as standard. Sealed units are supported on setting blocks and dry glazed with EPDM gaskets. All commercially available high performance glass types can be specified to meet particular requirements for thermal insulation, acoustic attenuation, solar control, safety, security and fire protection. PERFORMANCE All Westcoast products can be considered as genuinely high performance but frame size, glazing and other factors can, however, directly affect performance levels. Westcoast technical support staff should be consulted if particular data is required or for advice on how to achieve the most cost effective solution for specific performance targets. WEATHERTIGHTNESS Products comply with the following minimum performance standards when tested in accordance with: EN 1026 : 2000 (air permeability) EN 1027 : 2000 (watertightness) EN : 2000 (wind resistance) Air Permeability: 600 Pa (Class 4) In accordance with EN : 2000 Watertightness: 900 Pa (Class E900) In accordance with EN : 2000 Wind Resistance: 2000 Pa (Class A5) In accordance with EN : 2000 Exposure Category : 2000 In accordance with BS 6375 : Part 1 : 2009 THERMAL INSULATION Products can be glazed to provide whole window U values ranging from 1.4Wm 2 K to less than 0.8Wm 2 K in accordance with EN ISO : ACOUSTIC ATTENUATION Double and triple glazed products can be specified to achieve tested sound reductions in a range from 31 to 48dB(Rw) in accordance with EN ISO : SECURED BY DESIGN All principle products have been tested to comply with PAS 24: FIRE RESISTANCE Fixed and opening lights are classified EI45 and EI 2 45 in accordance with EN : A1 : 2009 when tested to EN : 1999 and EN : 2014 respectively. TESTING A continuous programme of internal and 3rd party independent testing ensures that Westcoast products remain at the very forefront of fenestration technology. INSTALLATION Westcoast windows and doors are supplied to site fully factory finished and glazed for installation into prepared openings. A comprehensive design and installation service is offered. MAINTENANCE Maintenance is limited to periodic washing of external aluminium and glass surfaces with water containing a mild detergent. Internal timber should be cleaned with a damp cloth or polished. Ironmongery items are made from corrosion resistant materials and require only annual inspection and lubrication of appropriate moving parts. Since our policy is one of continuous improvement, we reserve the right to change without prior notice the specifications and methods of construction described in this document. No responsibility whatsoever can be accepted for any errors or omissions in, or misrepresentations of the contents. Details shown are for guidance purposes only and may vary according to circumstances. For specific information, refer to Westcoast Windows Systems Limited. Copyright reserved.

9 SDC (BI-PARTING) LIFT & SLIDE DOOR DESIGN APPLICATION For residential access purposes at ground floor terrace or upper floor level balcony locations where large openings are required and doors are to be secured principally from within the building. FUNCTION A simple rotation of the operating handle disengages the sliding leaf from the multipoint locking bolts and at the same time, the mechanism allows the leaves to effortlessly slide into the open position. SBD U dB SLIDING HEAD IRONMONGERY Operating Gear: Lift and slide mechanism with handle engagement device. Internal Handle: Satin anodised finish lift and slide handle with cylinder lock. External Finger Pull: Satin anodised. A wide range of optional ironmongery items are available, please contact us for further information. SLIDING THRESHOLD 2600 H SLIDING JAMB W = Min/Max sizes Note: Size limits also depend on the weight of the glazing. For further information please contact our Technical Department.

10 THE SYSTEM STANDARDS CONSTRUCTION Composite construction combining extruded aluminium alloy profiles to EN AW 6060-T6 and close grained, laminated North European Redwood, durability Class 3 as defined in BS EN 350. Other timber species can be specified. Timber frame and casement sections are precision machined and assembled with pinned and glued comb joints. Mullions and transoms are assembled with mortice and tenon joints. External aluminium frame profiles are assembled with sealed mitred joints by means of crimped angle cleats, bonded with PIB tape and mechanically fixed with stainless steel pins to internal timber members. Windows are fully weatherstripped with EPDM or silicone slot seals. MANUFACTURE All windows and doors are purpose made to specification in accordance with BS 644 : 2009 and EN : APPEARANCE Aluminium profiles are chemically pre-treated and powder coated in any standard RAL colour in accordance with BS 6496 : Standard gloss level 75% +/- 5%. Other gloss levels can be specified. Timber is fully factory finished with a two or three coat spray applied water based clear lacquer gloss level 35%, paint to NCS/ RAL specification gloss level 40% or a wide range of standard stain finishes gloss level 35%. GLASS AND GLAZING Windows and doors are factory double or triple glazed to specification in accordance with BS 6262 : 1982 with 28mm, 36mm or 48mm dual sealed units constructed to EN : 2002 and safety glazed where applicable in accordance with BS 6206 : 1981 and Building Regulation 2000 Approved Document N. Products are typically externally bead glazed employing a drained and ventilated glazing system with sealed units incorporating warm edge composite super spacers and argon gas filling as standard. Sealed units are supported on setting blocks and dry glazed with EPDM gaskets. All commercially available high performance glass types can be specified to meet particular requirements for thermal insulation, acoustic attenuation, solar control, safety, security and fire protection. PERFORMANCE All Westcoast products can be considered as genuinely high performance but frame size, glazing and other factors can, however, directly affect performance levels. Westcoast technical support staff should be consulted if particular data is required or for advice on how to achieve the most cost effective solution for specific performance targets. WEATHERTIGHTNESS Products comply with the following minimum performance standards when tested in accordance with: EN 1026 : 2000 (air permeability) EN 1027 : 2000 (watertightness) EN : 2000 (wind resistance) Air Permeability: 600 Pa (Class 4) In accordance with EN : 2000 Watertightness: 900 Pa (Class E900) In accordance with EN : 2000 Wind Resistance: 2000 Pa (Class A5) In accordance with EN : 2000 Exposure Category : 2000 In accordance with BS 6375 : Part 1 : 2009 THERMAL INSULATION Products can be glazed to provide whole window U values ranging from 1.4Wm 2 K to less than 0.8Wm 2 K in accordance with EN ISO : ACOUSTIC ATTENUATION Double and triple glazed products can be specified to achieve tested sound reductions in a range from 31 to 48dB(Rw) in accordance with EN ISO : SECURED BY DESIGN All principle products have been tested to comply with PAS 24: FIRE RESISTANCE Fixed and opening lights are classified EI45 and EI 2 45 in accordance with EN : A1 : 2009 when tested to EN : 1999 and EN : 2014 respectively. TESTING A continuous programme of internal and 3rd party independent testing ensures that Westcoast products remain at the very forefront of fenestration technology. INSTALLATION Westcoast windows and doors are supplied to site fully factory finished and glazed for installation into prepared openings. A comprehensive design and installation service is offered. MAINTENANCE Maintenance is limited to periodic washing of external aluminium and glass surfaces with water containing a mild detergent. Internal timber should be cleaned with a damp cloth or polished. Ironmongery items are made from corrosion resistant materials and require only annual inspection and lubrication of appropriate moving parts. Since our policy is one of continuous improvement, we reserve the right to change without prior notice the specifications and methods of construction described in this document. No responsibility whatsoever can be accepted for any errors or omissions in, or misrepresentations of the contents. Details shown are for guidance purposes only and may vary according to circumstances. For specific information, refer to Westcoast Windows Systems Limited. Copyright reserved.

11 D E SI G N O P EN OUT DOOR S MEETING STILES & MIDRAIL DETAILS A A A-A FDG Meeting Stile ASSA B B B-B FDGL Meeting Stile C C D 125 ASSA D E C-C FDG Slim Midrail E D-D FDGL Slim Midrail E-E Transom for fanlight : System: Design Detail: Door SystemSystem Drawing No:DESIGN S009 Scale: A4 DOOR SYSTEM Detail : Drawing No. : S009 A4 Scale: T E L : E M A I L : I N F W E S T C O A S T W I N D O W S. C O M W W W.W E S TC O A S T W I N D O W S. C O M

12 DESIGN SLIDING DOORS MEETING STILES & MIDRAIL DETAILS A-A SDA Mullion B C 216 E-E SDC Meeting Stile A A B B C C E E B C B-B SDA Sliding Leaf Midrail C-C SDA Fixed Leaf Midrail System: Design Detail: Sliding Door System System Drawing : No: DESIGN S010 Scale: A4 Detail : SLIDING DOOR SYSTEM Drawing No. : S010 Scale: A4