No Fault Safety Tile Dimensions

Size: px
Start display at page:

Download "No Fault Safety Tile Dimensions"

Transcription

1 No Fault Sport Group, LLC 3112 Valley Creek Drive, Ste. C Phone: (225) Fax: (225) No Fault Safety Tile Dimensions 2 1/4" Tile 2 1/4" Tile 3-3/4 Tile 3 3/4" RAMP Dimensions- 24" x 24" Dimensions- 8" x 48" Dimensions: 24 x 24 Dimensions- 12" x 48" Thickness- 3 ¾ to 3/8 Underside of 2 ¼ Tile Underside of 3 ¾ Tile Corner Pieces

2 No Fault Safety Tile Accessories ADA Access Ramp 24" x 24" x 2.5" Left/Right Side Reducer ADA Access 24" x 8" x 2.5" 2.25" Reducer 48" x 8" X 2.5" Outside 45 Corner Reducer 16" x 8" x 2.5" Inside 45 Corner Reducer 12" x 8" x 2.5" Outside 90 Corner Reducer 16" x 8" x 2.5" Inside 90 Corner Reducer 12" x 8" x 2.5" 4 Corner Blok Connector 8" x 8" x 17mm

3 No Fault Sport Group, LLC 3112 Valley Creek Drive, Ste. C Baton Rouge, LA Fax: No Fault Safety Tiles Reducers and Ramps Page 1 of 1

4 NO FAULT SPORT GROUP, LLC 3112 VALLEY CREEK DRIVE, STE. C BATON ROUGE, LA FAX BACKFILL ALL CUTOUTS AROUND PLAY STRUCTURE SUPPORTS AND OTHER PENETRATIONS WITH NFSG URETHANE ADHESIVE NO FAULT SAFETY TILE DEPTH VARIES USE NFST RAMPS TO TRANSITION FROM TILES TO ADJACENT SURFACE AS NEEDED TYPICAL PLAY STRUCTURE SUPPORT CUT NFST AROUND PENERTRATIONS TO WITHIN ¼ MAX. OF PLAY STRUCTURE SUPPORT NFSG URETHANE ADHESIVE APPLIED AT SQ FT/GAL USING A ¼ V OR ⅛ SQ NOTCHED TROWEL CONCRETE OR ASPHALT BASE COMPACTED EARTH & AGGREGATE SUB-BASE CONCRETE FOOTER FOR PLAY STRUCTURE SUPPORT NOTES: 1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER S SPECIFICATIONS 2. CONCRETE OR ASPHALT BASE MUST BE WELL CURED (28 DAYS MIN.) AND DRY BEFORE APPLICATION OF THE NFSG URETHANE ADHESIVE 3. COLOR & DEPTH TO BE CONFIRMED WITH OWNER PRIOR TO INSTALLATION ABOVE GRADE, HARD BASE INSTALLATION NO FAULT SAFETY TILE

5 No Fault Sport Group, LLC 3112 Valley Creek Drive, Ste. C Baton Rouge, LA Fax

6 NO FAULT SAFETY TILES ALTERNATIVE INSTALLATION SYSTEM FOR ROOF-TOP & STONE SUB-BASE APPLICATIONS No Fault 4-Corner Lock Connector System No Fault Safety Tiles can be installed using a variety of installation methods. The most common and secure method is full adhesion of tiles and accessories to the substrates using EGrip, an easy-to-use one part polyurethane adhesive (provided with your order). EGrip's coverage is approximately 60 sq/ft on concrete, 50 sq/ft on asphalt and 45 sq/ft on protective fabric (1/8" square notched trowel) and is available in 2.5 or 5 gallon pails. For compacted stone sub-base, rooftop, and other specialty applications, we recommend No Fault 4-Corner Lock System. This system offers added stability and ease of installation and maintenance. Tiles are adhered to the 4-Corner Lock gird connector eliminating any potential damage to the sub-base or roof membrane. Replacing individual tiles and securing a strong, tight-fitting system is a snap with the No Fault Safety Tiles (4-Corner Lock System). Additionally, it uses EGrip Adhesive in 10.3 oz. caulk tubes, at a rate of one tube per ten 4-Corlner Lock connectors with a 3/8" bead. For more detailed installation instructions, please refer to the No Fault Safety Tiles Installation and maintenance manual.

7 NO FAULT SPORT GROUP, LLC 3112 VALLEY CREEK DRIVE, STE. C BATON ROUGE, LA FAX NFST 4-CORNER LOCK HALF CONNECTOR 2¼ NFST 3/8 DIAMETER BEAD OF NFSF URETHANE ADHESIVE.. TILE LEGS WILL MATE TO THESE CUTOUTS INSERT THE NFST HALF LOCK CONNECTOR SO THAT THE STAR SHAPE HOLE IS INBOARD NOTES: 1. ALL DIMENSIONS ARE SHOWN IN INCHES 2. ONE NFST 4 CORNER LOCK IS REQUIRED PER TILE 3. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER S SPECIFICATIONS 3/8 DIAMETER BEAD OF NFSF URETHANE ADHESIVE. APPROX. 11 LINEAR INCHES PER HALF CONNECTOR. 4-CORNER LOCK CONNECTORS NO FAULT SAFETY TILE

8 NO FAULT SPORT GROUP, LLC 3112 VALLEY CREEK DRIVE, STE. C BATON ROUGE, LA FAX NFST 4-CORNER LOCK FULL CONNECTOR TILE LEGS WILL MATE TO THESE CUTOUTS 3/8 DIAMETER BEAD OF NFSF URETHANE ADHESIVE. APPROX. 15 LINEAR INCHES PER FULL CONNECTOR. NFST 4-CORNER LOCK HALF CONNECTOR NOTES: INSERT THE NFST HALF LOCK CONNECTOR SO THAT THE STAR SHAPE HOLE IS INBOARD 3/8 DIAMETER BEAD OF NFSF URETHANE ADHESIVE. APPROX. 11 LINEAR INCHES PER HALF CONNECTOR. 1. ALL DIMENSIONS ARE SHOWN IN INCHES 2. ONE NFST 4 CORNER LOCK IS REQUIRED PER TILE 3. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER S SPECIFICATIONS 4-CORNER LOCK CONNECTORS NO FAULT SAFETY TILE