1 ASBESTOS INSPECTION AND REPORT WATCHTOWER PLAZA REDEVELOPMENT PAYDAY LOAN PROPERTY TH STREET ROCK ISLAND, IL 61201

2 EnviroNET, Incorporated Professional Environmental Services 1225 East River Drive #130 Davenport, IA Phone: April 30, 2013 City of Rock Island Attn: Tom Ayers 1528 Third Avenue Rock Island, IL SUBJECT: NESHAPS ASBESTOS SURVEY, SAMPLING & ANALYSIS WATCHTOWER PLAZA REDEVELOPMENT PROPERTY E LOCATED AT TH STREE, ROCK ISLAND, IL ENVIRONET PROJECT # Dear Mr. Ayers: EnviroNET, Inc. completed a field inspection of the subject property identified above on April 8, 2013, including evaluation and sampling of suspect asbestos-containing materials (ACM) in accordance with the authorized contract. General guidelines and requirements specified in the National Emissions Standard for Hazardous Air Pollutants (NESHAPs) and OSHA were followed. The attached Report provides results of the survey. We trust that the attached report meets your requirements. Thank you for allowing EnviroNET to assist you with this project. Sincerely, ENVIRONET, INC. Molly E. Arp Newell, PG, CHMM Asbestos Building Inspector Inspector IL License No Attachments: Asbestos Inspection Report with summary documentation, photographs, building schematic map, Analytical Report and Asbestos Inspector Credentials.

3 ASBESTOS INSPECTION WATCHTOWER PLAZA PROPERTY E TH STREET ROCK ISLAND, IL Prepared for: MR. TOM AYERS CITY OF ROCK ISLAND 1528 THIRD AVENUE ROCK ISLAND, IL Prepared by: ENVIRONET, INC EAST RIVER DRIVE #130 DAVENPORT, IA DATE: APRIL 30, 2013

4 Watchtower Plaza, Rock Island, IL EnviroNET, Inc. NESHAPs ACM Report - Property E April 30, 2013 ASBESTOS INSPECTION REPORT Field inspections were performed on April 8 & 23, 2013 at the subject property located at th Street in Rock Island, IL to determine the presence of asbestos containing materials (ACM). Suspect materials identified during the inspection were sampled and analyzed in accordance with federal and state NESHAPs requirements. This report itemizes materials tested and provides laboratory results of those materials. The approximate square footage / linear footage of the materials testing positive for ACM are provided together with the approximate location, where appropriate. Suspect bulk ACM samples, both friable and non-friable, were analyzed using polarized light microscopy to determine if the suspect ACMs contain more the 1% asbestos. Attachments include laboratory analytical reports, photographs of sample locations, the Township Assessor s information for the building, a schematic of the building layout, and the credentials of the inspectors. Inspection Summary The scope of inspection included the interior and exterior of the commercial structure. It was observed to be occupied by Payday Loans at the time of the inspection. The Property is targeted for demolition and redevelopment by the City of Rock Island. No-destructive sampling was employed to gather representative samples of suspect ACMs (asbestos containing materials). The inspection included apparent homogeneous sampling locations of suspect materials, including layers within materials. Random samples were collected from cove base/mastic, ceiling tiles, ceiling tile mastic, drywall, and carpet mastic. A minimum of three samples were collected from each homogeneous area. Samples were delivered to EMSL laboratories at its Chicago location to be analyzed for the presence of asbestiform material. The laboratory analyzed 33 bulk samples, including samples with multiple layers. The asbestos inspection was conducted in accordance with OSHA regulation 29 CFR , in specified areas agreed upon by the CLIENT. Analysis of the samples was completed by Polarized Light Microscopy Dispersion (PLM) Staining Method EPA/600/R-93/116. This survey did not include the internal components, material in storage within the building, or materials considered outside the definition of building materials. Care should be taken when removing, restoring, or disassembling these items. Description of the Buildings in the Scope of Work The survey took place April 8 & 23, 2013 at th Avenue, Rock Island, IL. The commercial structure is one story in height. There were no additional structures associated with the building, and no evidence of additions to the original wood frame structure. Per the Assessor s report, the building was constructed in 1980 and comprises approximately 1,768 square feet. The building foundation was observed to be a concrete slab on grade, with no basement. The frame is wood with rolled fiberglass insulation and exterior wood façade. The eastern portion of the roof is pitched with shingles and a metal drip edge; the western portion of the roof is flat with a plastic membrane. 1

5 Watchtower Plaza, Rock Island, IL EnviroNET, Inc. NESHAPs ACM Report - Property E April 30, 2013 The interior was observed to have a combination of drywall and wood paneling walls, suspended ceilings, and a combination of floor coverings. The east side of the building was observed to have newer carpet laid over concrete; the concrete underlay was confirmed in three individual locations. The two bathrooms and a west storage area were observed to have ceramic tile floors. A drywall ceiling is present above the suspended ceiling in the eastern portion of the building. Glued-on ceiling tiles were observed on this drywall ceiling. The structure is heated and cooled with a forced air system with an HVAC unit and condenser mounted on the roof. Suspect asbestos materials sampled and analyzed under the prescribed scope of work are listed below. Laboratory Analytical Results for Suspect Asbestos Containing Materials are Provided: Area Number CB-01 (A-C) CBM-01 (A-C) CT-01 (A-C) CT-02 (A-C) CT-03 (A-C) CTM-03 (A-C) DW-01 (A-C) Material Description Friable / Non Friable Cove Base n/a Dark brown Cove Base Mastic Tan colored, on CB- n/a 01 Ceiling Tile 2 x4 n/a Off-white, lines & dots pattern Ceiling Tile 2 x4 n/a, dots & fissures pattern Ceiling Tile 12 x12 n/a Above CT-02 (East 1/2) Ceiling Tile Mastic Broken mastic above NF CT-03 on drywall Drywall with mud DW-02 (A-C) Drywall n/a CM-01 (A-C) Yellow Carpet Mastic n/a RS-01 (A-C) Asphalt roof shingle n/a Area Location North Central Office West storage North Central Offices West storage Western approximate half Eastern approximate half Above CT-02 in the eastern approximate half Eastern approximate half Asbestos Content/Type Not Detected Not Detected Not Detected Not Detected Not Detected 2% Chrysotile n/a Walls Throughout Not Detected Ceiling, above CT-03/CTM-03 in the eastern approximate half Throughout eastern portion and west hallway/office On pitched roof (eastern portion of building) Not Detected Not Detected Not Detected 2

6 Watchtower Plaza, Rock Island, IL EnviroNET, Inc. NESHAPs ACM Report - Property E April 30, 2013 ACM Discussion Thirty-three (33) suspect bulk samples were analyzed. The following discussion includes individual materials determined to contain a minimum of 1% ACM: CTM-03 The ceiling tile puck mastic above CT-03 in the approximate eastern half (884 square feet) of the building was determined to contain a regulated quantity of asbestos. This material was found to contain 2% Chrysotile asbestos and is considered non-friable in its observed condition. The ACM material was observed to be stuck between acoustic ceiling tiles and drywall. Limitations to the Inspection The inspection was conducted systematically in accordance with NESHAPs requirements. The roofmounted sign contained caulking that was not accessible for sampling. Also not accessible was the attic above the eastern pitched roof; rolled fiberglass insulation was observed above the suspended ceiling in areas. EnviroNET cannot warrant that all ACM material was identified and analyzed, only that apparent materials were appropriately profiled. Because the Property was occupied, sampling there was aimed at inconspicuous locations. Carpet was pulled back from corners in most if not all rooms. EnviroNET surveyed accessible (interior and exterior) suspect asbestos containing materials, excluding the inventory, appliances, material in storage within the building, or materials considered outside the definition of building materials. Based on the experience of the inspectors and the observations made, the conclusions of this report are believed to be accurate and true, despite the limitations as described above. Recommendations: Asbestos abatement of CTM-03 is recommended prior to demolition of the building. Please contact our office with questions. Thank You. EnviroNET, Inc. Molly Arp Newell, PG, CHMM Illinois ACM Inspector License # One River Place 1225 East River Drive, Suite 130 Davenport, IA Office: CELL: Fax :

7 Watchtower Plaza, Rock Island, IL EnviroNET, Inc. NESHAPs ACM Report - Property E April 30, 2013 PHOTOGRAPHS

8 Photo 1: View of front (east face) of building looking west. Main entrances. Building exterior composed of wood siding and asphalt shingle roofing. Photo 2: View of north side of building looking south. Photo 3: View of back side (west face) of building looking east. Rear entry visible. NESHAPs Report th Street, Rock Island, IL

9 DW-01 Photo 4: View of south side of building looking northeast. Natural gas utility meter visible on concrete foundation. A flat roof is present over the western portion of the building; a pitched roof is present over the eastern portion of the building. Photo 5: View of interior office reception area. Ceiling tiles with drywall walls and carpet flooring. Thermostat visible to control roof-mounted HVAC system. CB-0l CBM-01 Photo 6: north central office CB-01 - Cove Base Dark brown in color, found in the northcentral office and west storage areas CBM-01 - Cove Base Mastic Tan colored on back side of CB-01 DW-01 Drywall No Asbestos Detected. NESHAPs Report th Street, Rock Island, IL

10 CT-03 Photo 7: CT-01- Ceiling Tile 2 x4 off-white with lines & dots pattern Located in the western portion View of fiberglass insulation above CT-01 No Asbestos Detected. Photo 8: CT-02 - Ceiling Tile 2 x4 white with dots & fissures pattern Located in the eastern portion No Asbestos Detected. CT-02 Photo 9: CT-03 - Ceiling Tile 12 x12 ceiling tile above CT-02 in the eastern portion of the building No Asbestos Detected. NESHAPs Report th Street, Rock Island, IL

11 CT-03 Wood paneling DW-02 CTM-03 Photo 10: CTM-03 - Ceiling Tile Mastic Brown in color, above CT-03 on drywall (DW-02). CTM-03 tested positive for asbestos 2% Chrysotile. Photo 11: Wood paneling is present in the western portion of the building. View of flex ductwork in ceiling cavity, and wood rafters (left side). Photo 12: Interior view of one of the restrooms. Ceramic tile (not sampled) and wood paneling. NESHAPs Report th Street, Rock Island, IL

12 DW-01 Photo 13: View of wood paneling (with gold pattern) above ceiling tile in the restrooms. Photo 14: DW-01 Drywall walls No Asbestos Detected. Photo 15: DW-01 Drywall with mud On ceiling and wall, viewed from the ceiling cavity (above CT-01) No Asbestos Detected. NESHAPs Report th Street, Rock Island, IL

13 Photo 16: Storage room in western portion of building accessed via rear door. Ceramic tile flooring with drywall. Photo 17: West storage room. Thorough inspection limited due to materials in storage blocking view of many surfaces. Photo 18: Fiberglass insulation above ceiling tiles in the western portion of the building. Wood rafters shown. NESHAPs Report th Street, Rock Island, IL

14 Photo 19: Plastic flat roof and shingled pitched roof, and roof-mounted HVAC unit. Photo 20: RS-01 roof shingles Metal drip edge & gutters (painted red) No Asbestos Detected. Photo 21: Brown caulking on screw plate associated with sign mounted onto the roof (not accessible). NESHAPs Report th Street, Rock Island, IL

15 Watchtower Plaza, Rock Island, IL EnviroNET, Inc. NESHAPs ACM Report - Property E April 30, 2013 BUILDING SCHEMATICS SAMPLE LOCATIONS

16 FIGURE 1: AERIAL VIEW Aerial View ENET # th Street Source: Google Maps Rock Island, IL N Scale: None NESHAPs Asbestos Inspection EnviroNET, Inc.

17 FIGURE 2: APPROXIMATE SAMPLE LOCATIONS = Greater than 1% ACM Parking Lot CT-01 CT-02 CT-03 CTM-03 Rear Entrance DW th Street CM-01 DW-01 CB-01 CBM-01 Parking Lot Building Layout View ENET # th Street Source: S. Rock Island Township Assessor Rock Island, IL N Scale: As shown NESHAPs Asbestos Inspection EnviroNET, Inc.

18 FIGURE 3: PARCEL VIEW Rock Island Township PIN # 5018 ENET # th Street Source: Rock Island County GIS Rock Island, IL N Scale: None NESHAPs Asbestos Inspection EnviroNET, Inc.

19 Watchtower Plaza, Rock Island, IL EnviroNET, Inc. NESHAPs ACM Report - Property E April 30, 2013 LABORATORY REPORT

20 EMSL Analytical, Inc W. Hubbard Street, Chicago, IL Phone/Fax: (773) / (773) chicagolab@emsl.com EMSL Order: CustomerID: ENET85 CustomerPO: ProjectID: Attn: Sara Schmuecker EnviroNET Midwest 1225 East River Dr., Suite #130 Davenport, IA Phone: (563) Fax: (563) Received: 04/09/13 9:05 AM Analysis Date: 4/16/2013 Collected: Project: Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M Method(s) using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous % % Type E-CB-01 A DK BRN COVEBASE-N. CENTR + WOFF. Brown 100% Non-fibrous (other) E-CB-01 B DK BRN COVEBASE-N. CENTR + WOFF. Brown 100% Non-fibrous (other) E-CB-01 C DK BRN COVEBASE-N. CENTR + WOFF. 100% Non-fibrous (other) E-CBM-01 A DK BRN COVEBASE-N. CENTR + WOFF.- MASTIC Yellow 100% Non-fibrous (other) E-CBM-01 B DK BRN COVEBASE-N. CENTR + WOFF.- MASTIC Yellow 100% Non-fibrous (other) E-CBM-01 C DK BRN COVEBASE-N. CENTR + WOFF.- MASTIC Yellow 100% Non-fibrous (other) E-CT-01 A X4 CEILING TILE OFF WHT- W LINES/DOTS Fibrous 60% 20% Cellulose Min. Wool 20% Non-fibrous (other) Analyst(s) James Hahn (9) Nick Neu (19) James Hahn, Laboratory Manager or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. Chicago, IL NVLAP Lab Code Initial report from 04/16/ :56:47 Test Report PLM Printed: 4/16/2013 8:56:47 AM 1

21 EMSL Analytical, Inc W. Hubbard Street, Chicago, IL Phone/Fax: (773) / (773) chicagolab@emsl.com EMSL Order: CustomerID: ENET85 CustomerPO: ProjectID: Attn: Sara Schmuecker EnviroNET Midwest 1225 East River Dr., Suite #130 Davenport, IA Phone: (563) Fax: (563) Received: 04/09/13 9:05 AM Analysis Date: 4/16/2013 Collected: Project: Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M Method(s) using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous % % Type E-CT-01 B X4 CEILING TILE OFF WHT- W LINES/DOTS Fibrous 60% 20% Cellulose Min. Wool 20% Non-fibrous (other) E-CT-01 C X4 CEILING TILE OFF WHT- W LINES/DOTS Gray Fibrous 50% 20% Cellulose Min. Wool 30% Non-fibrous (other) E-CT-02 A X4 CEILING TILE-WHITE Fibrous 70% 10% Cellulose Min. Wool 20% Non-fibrous (other) E-CT-02 B X4 CEILING TILE-WHITE Fibrous 70% 10% Cellulose Min. Wool 20% Non-fibrous (other) E-CT-02 C X4 CEILING TILE-WHITE Fibrous 70% 10% Cellulose Min. Wool 20% Non-fibrous (other) E-CT-03 A X12 CEILING TILE (THE ABV CT-02) Fibrous 80% Min. Wool 20% Non-fibrous (other) E-CT-03 B X12 CEILING TILE (THE ABV CT-02) Fibrous 80% Min. Wool 20% Non-fibrous (other) E-CT-03 C X12 CEILING TILE (THE ABV CT-02) Fibrous 80% Min. Wool 20% Non-fibrous (other) Analyst(s) James Hahn (9) Nick Neu (19) James Hahn, Laboratory Manager or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. Chicago, IL NVLAP Lab Code Initial report from 04/16/ :56:47 Test Report PLM Printed: 4/16/2013 8:56:47 AM 2

22 EMSL Analytical, Inc W. Hubbard Street, Chicago, IL Phone/Fax: (773) / (773) chicagolab@emsl.com EMSL Order: CustomerID: ENET85 CustomerPO: ProjectID: Attn: Sara Schmuecker EnviroNET Midwest 1225 East River Dr., Suite #130 Davenport, IA Phone: (563) Fax: (563) Received: 04/09/13 9:05 AM Analysis Date: 4/16/2013 Collected: Project: Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M Method(s) using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous % % Type E-CTM-03 A X12 CEILING TILE (THE ABV CT-02) TILE MASTIC-BRN Brown 98% Non-fibrous (other) 2% Chrysotile E-CTM-03 B X12 CEILING TILE (THE ABV CT-02) TILE MASTIC-BRN Stop Positive (Not Analyzed) E-CTM-03 C X12 CEILING TILE (THE ABV CT-02) TILE MASTIC-BRN Stop Positive (Not Analyzed) E-DW-01 A-Drywall DRYWALL- WALLS 10% Cellulose 90% Non-fibrous (other) E-DW-01 A-Joint Compound DRYWALL- WALLS 100% Non-fibrous (other) A E-DW-01 B-Drywall DRYWALL- WALLS 10% Cellulose 90% Non-fibrous (other) E-DW-01 B-Joint Compound DRYWALL- WALLS 100% Non-fibrous (other) A Analyst(s) James Hahn (9) Nick Neu (19) James Hahn, Laboratory Manager or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. Chicago, IL NVLAP Lab Code Initial report from 04/16/ :56:47 Test Report PLM Printed: 4/16/2013 8:56:47 AM 3

23 EMSL Analytical, Inc W. Hubbard Street, Chicago, IL Phone/Fax: (773) / (773) chicagolab@emsl.com EMSL Order: CustomerID: ENET85 CustomerPO: ProjectID: Attn: Sara Schmuecker EnviroNET Midwest 1225 East River Dr., Suite #130 Davenport, IA Phone: (563) Fax: (563) Received: 04/09/13 9:05 AM Analysis Date: 4/16/2013 Collected: Project: Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M Method(s) using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous % % Type E-DW-01 C-Drywall DRYWALL- WALLS 10% Cellulose 90% Non-fibrous (other) E-DW-01 C-Joint Compound DRYWALL- WALLS 100% Non-fibrous (other) A E-DW-02 A DRYWALL ON CEILING (ABV CT-03) 10% 5% Cellulose Glass 85% Non-fibrous (other) E-DW-02 B DRYWALL ON CEILING (ABV CT-03) 10% 5% Cellulose Glass 85% Non-fibrous (other) E-DW-02 C DRYWALL ON CEILING (ABV CT-03) Heterogeneous 10% 5% Cellulose Glass 85% Non-fibrous (other) E-CM-01 A YELLOW CARPET MASTIC Yellow 100% Non-fibrous (other) E-CM-01 B YELLOW CARPET MASTIC Yellow 100% Non-fibrous (other) E-CM-01 C YELLOW CARPET MASTIC Yellow 100% Non-fibrous (other) Analyst(s) James Hahn (9) Nick Neu (19) James Hahn, Laboratory Manager or other approved signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. Chicago, IL NVLAP Lab Code Initial report from 04/16/ :56:47 Test Report PLM Printed: 4/16/2013 8:56:47 AM THIS IS THE LAST PAGE OF THE REPORT. 4

24

25

26 Watchtower Plaza, Rock Island, IL EnviroNET, Inc. NESHAPs ACM Report - Property E April 30, 2013 TOWNSHIP ASSESSOR S PROPERTY INFORMATION

27 Susan J. Carpentier, Assessor CIAO-I th Avenue Rock Island, IL South Rock Island Township Property Record Card Fax: Parcel #: Property Address: th street Rock Island, IL Billing Info.: R Own Properties, LLC P. O. Box 1042 Moline, IL Website: Property Class: 0060 Commercial Tax District: 02 Zoning: Neigh Code: Legal Description: Watch Tower 2nd Addition lot 2 sheet 20 Old PIN #: 5018 Assessment Information 2011 Land: 23,469 Improv: 30,110 Total: $53,579 Lot Size: Sq. Ft Acres Rough Dimensions: 0.00 by 0.00 Sale Information Date: 03/22/2012 Amount: $481,890 General Information Type of Use: Subdivision: Model Name: Classification: Office Watch Tower 2nd Addition 1 story 1.0 Story Bedrooms: 0 Total Rooms: 0 Total Ground Sq. Ft.: Total Building Sq. Ft.: 1,768 1,768 Year Built: 1980 Exterior Wall - Frame / Brick / Stone Basement - # of Baths - Extra Fixtures: Garage - Central A/C: Fireplace - Full: Partial: Crawl: Wood Burning Stove: Deck: Patio: Attached Yes Yes Full Other Half 0 1 Yes Sq. Ft. Deed Type: Warranty Sale Type: Contract Porch - Open / Enclosed Attic - Frame Masonry 0 0 Finished / Unfinished / None Yes 0 0

28 Watchtower Plaza, Rock Island, IL EnviroNET, Inc. NESHAPs ACM Report - Property E April 30, 2013 INSPECTOR QUALIFICATIONS

29 INSPECTOR QUALIFICATIONS