Table of Contents. Main Project Contacts. Finish Selections. Kitchen Equipment. Data Sheets / Operation & Maintenance Data

Size: px
Start display at page:

Download "Table of Contents. Main Project Contacts. Finish Selections. Kitchen Equipment. Data Sheets / Operation & Maintenance Data"

Transcription

1 European Street San Marco Building Manual 1105 San Marco Boulevard Jacksonville, Florida Table of Contents Main Project Contacts Finish Selections Kitchen Equipment Data Sheets / Operation & Maintenance Data

2 European Street San Marco Building Manual 1105 San Marco Boulevard Jacksonville, Florida Main Project Contacts General Contractor: Architect: Cabinets / Bathroom Partitions: Storefront Windows / Doors: Epoxy Flooring: Other Flooring: Plumbing: Air Conditioning: Electrical: Intracoastal Builders Corporation Matthew Reimer ibcreimer@gmail.com Doherty Sommers Architects Engineers Craig Sommers Bush Construction Company Andy Verchick Brad s Glass Company Tom Vermilya Advanced Surface Concepts Mark Thomas Action Commercial Flooring Verne Altenbaugh American Plumbing Contractors Randy Miller, Jr Howard Services Stuart Caron Southern Atlantic Electric Company Frank Woodcock

3 European Street San Marco Building Manual 1105 San Marco Boulevard Jacksonville, Florida Finish Selections Cabinets & Countertops Bathroom Millwork Bathroom FRP Paneling Marlite Paint Stain / Sealer Ceilings Countertop Samsung Staron Quarry Bluff QB244 Cabinets Winsonart Grey Toe Kick Wilsonart Monticello Maple Countertop Corian Bone Kick Panel Stainless Steel Partition Laminate Mission Maple Glasboard Pearl Gray 48 Pebbled Embossed Finish Faux Woodgrain 148 Monticello Anigre Sherwin Williams Gray SW6003 Proper Gray Sherwin Williams - Dark Gray - SW Mink Sherwin Williams - Yellow - SW Confident Yellow Sherwin Williams - Purple - SW Majestic Purple Walls ProMar 200 EgShel Bathrooms - Epoxy Door Frames All Surface Industrial Enamel Satin Minwax - Gunstock - Base and Shoe Mold Minwax - Colonial Maple Doors Helmsman Waterborne Satin ACT - Field - Tegular - 2x2 Armstrong Cortega - CTA 1774 White ACT - Kitchen - 2x2 Vinyl Faced Gypsum - Model # CTGN24 - Gridstone 2'x4'x1/2" Vinyl panel17 Metal Tiles - 2x2 -Metallaire Large Floral Circle White 24" x 24" - Model # LWH Flooring Epoxy Sherwin Williams, Ceramic Carpet - E-220 Sagebrush - Gloss Vinyl Commercial Tile Sagona Mesa Verde 18x18

4 European Street San Marco Building Manual 1105 San Marco Boulevard Jacksonville, Florida Floor Cleaning Notes From Installer The Maintenance and Cleaning Instructions from Sherwin Williams are attached. We suggest using Simple Green for everyday cleaning and use TSP for heavy duty grease or stains. DO NOT use any citric or acid based products.

5 European Street San Marco Building Manual 1105 San Marco Boulevard Jacksonville, Florida Kitchen Equipment

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48 European Street San Marco Building Manual 1105 San Marco Boulevard Jacksonville, Florida Data Sheets / Operation & Maintenance Manuals

49 Wilsonart Laminate Basic Types (#107, #335, #350) Technical Data Manufacturer Wilsonart LLC 2400 Wilson Place P.O. Box 6110 Temple, Texas Phone: (254) ; (800) Fax: (254) Web Site: Product Description Recommended Uses Wilsonart Laminate is suitable for use on fine quality residential and contract furniture, fixtures and casework, and also for architectural application on columns, wainscoting, valances, cornices, interior doors and divider systems. General Purpose (HGS) Type 107 is most frequently used for work surfaces on counters, islands, vanities, desks and tables. Typical vertical uses include surfacing for wall panels, teller cages and the front panels of workstations, such as those in hospitals, airports and restaurants. Type 107 is produced for both horizontal and vertical interior applications where the surface must be functional, durable and decorative. Vertical Surface (VGP) Type 335 is the usual choice to surface cabinet walls, doors and drawer panels. It often appears on the vertical surfaces of desks, restaurants booths and maitre d stations, and as architectural cladding. Type 335 is intended for vertical applications where a functional, durable, decorative surface must absorb somewhat less impact than a comparable horizontal surface. VGP surfaces may be postformed to achieve radiused edges. Postforming (HGP) Type 350 adds the decorative capability of a soft edge to any typical laminate use. Common applications of postforming laminates are formed edges for counters, desktops, cabinet doors and drawer panels. Type 350 is intended for use on vertical and horizontal interior surfaces where it is necessary or desirable to roll the laminate on a simple radius over the edge of the substrate. This eliminates seams and leaves an attractive surface. Product Composition Decorative surface papers impregnated with melamine resins are pressed over kraft paper core sheets impregnated with phenolic resin. These sheets are then bonded at pressures greater than 1000 pounds per square inch at temperatures approaching 300 F (149 C). Finished sheets are trimmed, and the backs are sanded to facilitate bonding. Basic Limitations Wilsonart Laminate is for interior use only and is not recommended for direct application to plaster, concrete walls, or gypsum wallboard. It is not structural material and must be bonded to a suitable substrate. Do not subject Wilsonart Laminate to extremes in humidity, temperatures higher than 275 F (135 C) for substantial periods of time, or intense, continuous, direct sunlight. Patterns & Colors Available in the full range of Wilsonart solid colors, stones, marbles, woodgrains, leathers and patterns. Please see actual sample before specifying. 1

50 Finishes You can confirm finish availability on individual designs by clicking on Pattern Availability #01 High Gloss - Premium A mirror sheen finish, which gives a smooth, brilliant appearance. #01-High Gloss finish also features AEON technology and can be used for horizontal applications such as countertops and light-to-medium commercial applications. Excellent for vertical applications and carries a premium upcharge. Glossometer reading: MD and CD 110 ± 10. #07 Textured Gloss - Premium A textured finish which reproduces the high sheen of waxed wood furniture. Recommended for horizontal and vertical applications. #07 finish features AEON technology and carries a premium upcharge. Glossometer reading: MD and CD 42 ± 4. #12 Soft Grain - Premium A dense wood grain structure that is low gloss and soft to the touch. Subtle highlights of reflectivity randomly occur within the embossed grains, creating a sophisticated raw wood look. #12 finish features AEON technology and carries a premium upcharge. Recommended for horizontal and vertical applications. Glossometer reading: MD and CD 6 ± 1. #18 Linearity - Premium A directional texture running the length of the sheet, having a narrow, random, matte-gloss linear quality. It is complementary to linear wood-grains, and linear patterns (such as the Satin series), and provides dimension and visual movement to solid colors. #18 finish features AEON technology and carries a premium upcharge. Glossometer reading: MD and CD 18 ± 4 #22 Antique - Premium A mixture of varying low gloss features combined with organic movement, indicative of the surface of an aged stone or an antique metal. Recommended for horizontal and vertical applications. Antique features AEON Enhanced Performance Technology and carries a premium upcharge. Glossometer reading: MD and CD 9 3 #38 Fine Velvet Texture A smooth textured finish with moderate reflective value. Glossometer reading: MD and CD 14 2 #52 Quarry - Premium Premium finish emulating the pitted look of polished natural stone. Recommended for horizontal and vertical applications. #52 features AEON technology and carries a premium upcharge. Glossometer reading: MD #60 Matte Textured finish with a moderate reflective quality. Recommended for horizontal and vertical applications. Glossometer reading: MD and CD #78 FineGrain - Premium The FineGrain premium finish features the polish and luxe of a real wood veneer, with a subtle, narrow grain structure that runs the length of the sheet. #78 finish features AEON technology and carries a premium. Glossometer reading: MD and CD NOTE: Glossometer readings are made at a 60 angle of incidence. MD refers to the machine direction of a laminate sheet, and CD refers to the cross direction. Finish Availability: Not all finishes are available in all patterns/colors. Some finish options have limited size availability. Please check with your Wilsonart representative or consult the pattern availability lookup on our website ( to verify size availability by finish type. 2

51 Standard Sheet Widths mm 1219mm 1524mm Standard Sheet Lengths mm 3048mm 3658mm NOTE: Not all sizes are available from stock; contact your Wilsonart representative for details on local availability. Minimums apply to non-standard designs and finishes in sizes other than 48 x96 and 60 x144. Please check with your Wilsonart representative. Thickness and Weight Description Thickness ± (1.22mm ± 0.13mm) (0.7mm mm) ± (0.99mm ± 0.13mm) Weight per square foot 0.322# 0.186# 0.260# Technical Data Physical Properties of General Purpose Laminates NEMA Test Typical Wilsonart Type 107 Thickness (1.22mm 0.13mm) Appearance No ABC def. No ABC def. Light Resistance Slight effect Slight effect Cleanability (cycles) (max.) Stain Resistance Reagents 1-10 Reagents NEMA Standard HGS (1.2mm 0.13mm) No effect Slight effect No effect Moderate effect Boiling Water Resistance No effect No effect High Temperature Resistance Slight effect Slight effect Impact Resistance 65 (1651mm) 50 (1270mm) Radiant Heat Resistance 160 seconds 125 sec. (min.) Dimensional Stability Machine Direction Cross Direction 0.3% 0.7% Meets or Exceeds % 0.9% 400 (min.) Surface Wear Resistance (cycles) Formability Not applicable Not applicable Blistering Not applicable Not applicable 3

52 Physical Properties of Vertical Surface Laminates NEMA Test Typical Wilsonart Type 335 NEMA Standard VGS Thickness (0.7mm mm) (0.7mm 0.10mm) Appearance No ABC def. No ABC def. No ABC def. Light Resistance Slight effect Slight effect Slight effect Cleanability (cycles) (max.) 20 (max.) Stain Resistance Reagents 1-10 Reagents NEMA Standard VGP (0.7mm 0.10mm) No effect Slight effect No effect Moderate effect No effect Moderate effect Boiling Water Resistance No effect No effect Slight effect High Temperature Slight effect Slight effect Slight effect Resistance Impact Resistance 40 (1016mm) 20 (508mm) 20 (508mm) Radiant Heat Resistance 120 seconds 80 sec. (min.) 80 sec. (min.) Dimensional Stability Machine Direction Cross Direction 0.5% 0.7% (max.) 1.1% (max.) 0.8% 1.2% (max.) 1.4% (max.) Meets or Exceeds (min.) 400 (min.) Surface Wear Resistance (cycles) Formability 7/16 radius (11mm) Not applicable 1/2 radius (13mm) Blistering 45 seconds Not applicable 40 seconds *Radius for face is actually the radius of the form around which the laminate is postformed. The radius for back is actually the radius to which the decorative face is postformed. Physical Properties of Postforming Laminate NEMA Test Typical Wilsonart Type 350 Thickness (0.99mm 0.13mm) Appearance No ABC def. No ABC def. Light Resistance Slight effect Slight effect Cleanability (cycles) (max.) Stain Resistance Reagents 1-10 Reagents NEMA Standard HGP (1mm 0.12mm) No effect Slight effect No effect Moderate effect Boiling Water Resistance No effect Slight effect High Temperature Resistance Slight effect Slight effect Impact Resistance 55 (1397mm) 30 (762mm) (min.) Radiant Heat Resistance 140 seconds 100 sec. (min.) Dimensional Stability Machine Direction Cross Direction 0.5% 0.8% 1.1% (max.) 1.4% (max.) Surface Wear Resistance Meets or Exceeds (min.) (cycles) Formability* *9/16 face (14.28mm) *5/8 face (16.00mm) *3/16 back (4.76mm) Blistering 70 seconds 55 seconds *Radius for face is actually the radius of the form around which the laminate is postformed. The radius for back is actually the radius to which the decorative face is postformed. 4

53 Typical Fire Test Data High-pressure laminates are subject to Flame Spread and Smoke Developed standards in structures where codes establish such conditions. Test data to determine compliance with these codes are obtained by the Steiner Tunnel Test method of the American Society for Testing Materials (ASTM-E-84, Standard Test Method for Surface Burning Characteristics of Building Materials). Tests were conducted in accordance with test method and mounting procedure as described in paragraph X1.7.2 of the test method. This procedure is cataloged by Underwriters Laboratories, Inc. as UL 723. Here is typical data for Wilsonart laminates, averaged from two specific tests: Typical Flame Spread and Smoke Developed Properties Product Type Test Condition Flame Spread Smoke Developed General Purpose Unbonded Type 107 Vertical Surface Unbonded Type 335 Postforming Unbonded Type 350 General Purpose Type 107 Bonded with contact adhesive to particleboard Vertical Surface Type 335 substrate; 3/8 Bonded with contact adhesive to particleboard substrate; 3/ Product Type Test Condition Flame Spread Smoke Developed Postforming Type 350 Bonded with contact adhesive to particleboard substrate; 3/8 When you wish to specify decorative laminate for a Class I or A fire rating, please refer to the Fire- Rated Laminate Tech Data. Model Code Designations used to determine flame spread classification Flame Spread International Classification (IBC) (Max. Rating) Life Safety (NFPA 101) 25 A A 75 B B 200 C C (RE: Architectural Woodwork Quality Standard, 8 th Edition, Version 1.0, ) All Model Codes regulate the generation of smoke by interior finish material. In all cases they specify a maximum smoke development rating of

54 Codes and Certifications General Standards Wilsonart laminates conform to the voluntary standards of the American National Standards Institute/National Electrical Manufacturers Association (ANSI/NEMA) LD3-2005, for thickness, performance properties and appearance. Various grades of Wilsonart laminates meet or exceed the International Standards Organization specifications as found in ISO 4586, titled High-Pressure Decorative Laminate (HPDL) Sheets Based on Thermosetting Resins Part I: specifications. Specific Product Standards U.S. Federal Specification L-P 508H, April 9, 1977, Plastic Sheets, Laminated, Decorative and Nondecorative. Spells out criteria for decorative laminates for federal installations. Wilsonart 107, 335 and 350 laminates comply. NSF International (NSF) #35, Laminated Plastic for Surfacing for Food Service Equipment. All solid colors and printed patterns in Basic Types 107, 335 and 350, comply. U.S. Federal Register, August 9, 1984, Housing and Urban Development Mobile Home Construction and Safety Standard, (24CFR) General Purpose Type 107 and Vertical Surface Type 335 comply. U.S. Federal Test Method, Federal Aviation Regulation, DOT, Part , Airworthiness Standards: Transport Category Airplane (Interior Finish). Vertical Surface Type 335 and Postforming Type 350 comply with parts a and c. U.S. Federal Motor Vehicle Safety Standard (FMVSS) 302, Flammability of Interior Materials. Basic Types 107, 335 and 350 comply. U.S. Military Standard MIL-P-17171E (SHIPS)/Plastic Laminate. General Purpose Type 107 complies. Installation: Fabrication and Assembly Recommendations Fabrication should follow approved methods. Assembled pieces should meet the specifications of KCMA (Kitchen Cabinetmakers Manufacturers Association), ANSI A (revised), and Architectural Woodwork Quality Standards, Guide Specifications and Quality Certification Program guidelines of the Architectural Woodwork Institute where applicable. Wilsonart laminates must be bonded to a substrate of reliable quality, such as particleboard, medium density fiberboard or plywood with one A face. High-pressure laminate, plaster, concrete and gypsum board should not be considered suitable substrates. Basic Types laminate may not be used as structural members. Bond with adhesives and follow the techniques recommended by the adhesive manufacturer. Recommended adhesives are permanent types, such as urea and polyvinyl acetate (PVA), and contact types. Wilsonart adhesives are recommended for most bonding conditions. To avoid stress cracking, do not use square-cut inside corners. All inside corners should have a minimum of 1/8 (3.175mm) radius and all edges should be routed smooth. Drill oversized holes for screws or bolts. Screws or bolts should be slightly countersunk into the face side of a laminate-clad substrate. Take care to ensure an appropriate acclimation between the laminate and the substrate prior to fabrication. The face and backing laminates and the substrate should be conditioned in the same environment for 48 hours before fabrication. 6

55 Recommended conditioning temperature is about 75 F (24 C). Laminates should be conditioned at 45% to 55% relative humidity. With postforming machinery, Wilsonart 335 and 350 will postform at a nominal sheet temperature range of 325 F to 338 F (163 C to 170 C) in 20 5 seconds. Carbide-tipped saw and router blades should be used for cutting. High tool speed and low feed speed are advisable. Cutting blades should be kept sharp. Use a hold-down to prevent any vibration. Warranty Wilsonart LLC warrants to the original consumer purchaser for one (1) year after date of purchase ( Warranty Period ) that, under normal use and service, Wilsonart Laminate Sheets are free from manufacturing defects and conform to published specifications. This warranty applies only to a Wilsonart Laminate Sheet which has been installed in an interior application and a remains installed at that location ( Warranted Product ) and is extended only to, and may be enforced only by, the original consumer purchaser. THIS WARRANTY IS NOT TRANSFERABLE. This warranty is expressly conditioned upon submission of proof of date of purchase. WHAT IS EXCLUDED: This warranty shall not apply to damage arising from any of the following: 1. Accidents, abuse or misuse; 2. Exposure to extreme temperature; 3. Improper fabrication or installation; or 4. Improper maintenance or repair. WHAT WILSONART WILL DO IF YOUR CLAIM IS COVERED BY THIS WARRANTY Wilsonart will provide, at no cost and with delivery prepaid, a Wilsonart Laminate Sheet to replace the Warranted Product. Wilsonart will not pay for removal of the Warranted Product or for fabrication or installation of the replacement laminate or any other costs. No replacement under the warranty shall extend the Warranty Period. Any replacement is limited to colors and styles of Wilsonart Laminate Sheets available at the time of replacement. Exact color matches may not be possible. If the original color or style is no longer available, Wilsonart has the right to substitute another Wilsonart Laminate Sheet of equal or greater value than the Warranted Product. WHAT YOU NEED TO DO To make a claim under this warranty, you must contact the Wilsonart Warranty Center at the address listed below before the end of the Warranty Period. You must provide proof of date of purchase, photographs of the Warranted Product and access for inspection for warranty determination by a Wilsonart representative, and thereafter Wilsonart will provide you a determination on your claim. Wilsonart Warranty Center 2400 Wilson Place Temple, Texas Toll Free THE FOREGOING SHALL CONSTITUTE THE EXCLUSIVE REMEDY OF THE PURCHASER AND THE EXCLUSIVE LIABILITY OF WILSONART. THE ABOVE WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES WHETHER ORAL OR WRITTEN. ANY IMPLIED WARRANTIES WHICH MAY ARISE BY OPERATION OF LAW, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE PERIOD OF THE WRITTEN WARRANTY SET FORTH HEREIN. 7

56 WILSONART SHALL NOT, UNDER ANY CIRCUMSTANCES OR UNDER ANY LEGAL THEORY, BE LIABLE TO THE PURCHASER OR ANY OTHER PERSON FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, INCLUDING WITHOUT LIMITATION DAMAGES TO, OR LOSS OF USE OF, PROPERTY, DAMAGES FOR LOSS OF PROFITS OR REVENUES OR ANY OTHER DAMAGES ARISING FROM THE PURCHASE. WILSONART'S LIABILITY WILL IN NO EVENT EXCEED THE PURCHASE PRICE OF THE WILSONART PRODUCT. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitations and exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. No agent, dealer, employee or representative of Wilsonart nor any installer, fabricator or other person is authorized to modify the warranty in any respect. The invalidity of all or a part of any of the provisions of the Limited Warranty shall not affect or invalidate any other provision of the Limited Warranty. For further assistance or questions, contact Wilsonart at the address or telephone number listed above or at Maintenance* The decorative surface may be cleaned with warm water and mild soaps, such as those used for hands or dishes. Do not use cleansers that contain abrasives, acids or alkalis; they will damage the decorative surface. Remove stubborn stains with a 2-minute exposure to hypochlorite bleach such as Clorox, followed by a clean water rinse. We recommend that you not allow any of the following agents to remain in contact with the decorative surface: 1. Hypochlorite bleach, except as described above 2. Hydrogen peroxide solution 3. Mineral acids, hydrochloric acid such as Lime-A-Way, sulfuric or nitric acid 4. Caustic solutions containing greater than 2% lye, such as Drano 5. Sodium bisulfate, such as Sani-Flush 6. Potassium permanganate 7. Berry juices 8. Silver nitrate, in 1% concentration or greater 9. Gentian violet 10. Mild silver protein, such as 20% argyrol 11. Bluing 12. Fabric dye, such as Tintex or Rit 13. Alcohol containing 1% iodine in solution If you require a decorative laminate that can withstand these and other chemicals, please refer to the Tech Data for Wilsonart Chemsurf Chemical-Resistant Laminates. Free copies of the Care and Maintenance Guide, which covers all Wilsonart products, are available. The guide can be accessed at or by calling our hotline at It can be used for your own information, for project manuals, and for provision to clients and contractors involved with interior construction and finishing. *Not applicable for Phenolic Laminate Backing Sheet. 8

57 Technical Services For samples, literature, questions or technical assistance, please contact our toll-free Hotline at (800) , Monday through Friday, 8 am 5 pm, CST. Specification Form: Surface shall be Wilsonart Laminate, produced by Wilsonart LLC, Temple, Texas Type: Specify 107, 335 or 350 Surface Color Number: Color Name: Finish Number: Name: Edge Trim Color Number: Color Name: Adhesive Name: Grade/Type: Brand: Wilsonart Adhesive Basic Types TD (TD2200) Revised: October 22, , Wilsonart LLC 9

58 Wilsonart LLC 2400 Wilson Place Temple, Tx Fax: WHAT IS COVERED: Wilsonart Laminate Sheets WILSONART LAMINATE LIMITED WARRANTY Wilsonart LLC ( Wilsonart ) warrants to the original consumer purchaser for one (1) year after date of purchase ( Warranty Period ) that, under normal use and service, Wilsonart Laminate Sheets are free from manufacturing defects and conform to published specifications. This warranty applies only to a Wilsonart Laminate Sheet which has been installed in an interior application and remains installed at that location ( Warranted Product ) and is extended only to, and may be enforced only by, the original consumer purchaser. THIS WARRANTY IS NOT TRANSFERABLE. This warranty is expressly conditioned upon submission of proof of date of purchase. WHAT IS EXCLUDED: This warranty shall not apply to damage arising from any of the following: 1. Accidents, abuse or misuse; 2. Exposure to extreme temperature; 3. Improper fabrication or installation; or 4. Improper maintenance or repair. WHAT WILSONART WILL DO IF YOUR CLAIM IS COVERED BY THIS WARRANTY Wilsonart will provide, at no cost and with delivery prepaid, a Wilsonart Laminate Sheet to replace the Warranted Product. Wilsonart will not pay for removal of the Warranted Product or for fabrication or installation of the replacement laminate or any other costs. No replacement under the warranty shall extend the Warranty Period. Any replacement is limited to colors and styles of Wilsonart Laminate Sheets available at the time of replacement. Exact color matches may not be possible. If the original color or style is no longer available, Wilsonart has the right to substitute another Wilsonart Laminate Sheet of equal or greater value than the Warranted Product. WHAT YOU NEED TO DO To make a claim under this warranty, you must contact the Wilsonart Warranty Center at the address listed below before the end of the Warranty Period. You must provide proof of date of purchase, photographs of the Warranted Product and access for inspection for warranty determination by a Wilsonart representative, and thereafter Wilsonart will provide you a determination on your claim. Wilsonart Warranty Center 2400 Wilson Place Temple, Texas Toll Free THE FOREGOING SHALL CONSTITUTE THE EXCLUSIVE REMEDY OF THE PURCHASER AND THE EXCLUSIVE LIABILITY OF WILSONART. THE ABOVE WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES WHETHER ORAL OR WRITTEN. ANY IMPLIED WARRANTIES WHICH MAY ARISE BY OPERATION OF LAW, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE PERIOD OF THE WRITTEN WARRANTY SET FORTH HEREIN.

59 WILSONART SHALL NOT, UNDER ANY CIRCUMSTANCES OR UNDER ANY LEGAL THEORY, BE LIABLE TO THE PURCH ASER OR ANY OTHER PERSON FOR SPECIAL, I NCIDENTA L OR CONSEQUENTIAL DAMAGES OF ANY NATURE, INCLUDING WITHOUT LIMITATION DAMAGES TO, OR LOSS OF USE OF, PROPERTY, DAMAGES FOR LOSS OF PROFITS OR REVENUES OR ANY OTHER DAMAGES ARISING FROM THE PURCHASE. WILSONART'S LIABILITY WILL IN NO EVENT EXCEED THE PURCHASE PRICE OF THE WILSONART PRODUCT. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitations and exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. No agent, dealer, employee or representative of Wilsonart nor any installer, fabricator or other person is authorized to modify the warranty in any respect. The invalidity of all or a part of any of the provisions of the Limited Warranty shall not affect or invalidate any other provision of the Limited Warranty. For further assistance or questions, contact Wilsonart at the address or telephone number listed above or at Rev

60 Guide Specification SECTION DECORATIVE PLASTIC LAMINATE This Section specifies Wilsonart Decorative Plastic Laminates produced by Wilsonart. Wilsonart offers a wide range of laminate products with colors and patterns to suit virtually any residential or commercial need. Wilsonart is the largest and most-recognized manufacturer of laminates in the United States with a substantial presence in the global marketplace. Wilsonart Laminates are the preferred design option for fine quality residential and contract furniture, fixtures and casework. Interior architectural applications such as columns, wainscoting, valances, cornices, interior doors, and divider systems are ideal for laminate finish solutions. Wilsonart has also developed specialty uses such as visual display surfaces, fire-rated and chemical resistant surfaces. Wilsonart Laminates contribute to LEED-NC and LEED-CI points in several categories and have attained UL GREENGUARD Gold Certification and SCS Gold Certification for low indoor air chemical emissions into indoor air during product usage. Section Editing: Informational notes will appear as Editing Note text boxes throughout this Section. Bracketed bold text will require a selection to be made or information to be inserted. PART 1 - GENERAL 1.01 SECTION INCLUDES EDITING NOTE: Revise listing to suit Project requirements. A. Standard Decorative Laminates. B. High Definition Laminates. C. Solicor Laminates. D. x You Laminates. E. Virtual Design Library Laminates. F. Markerboard Laminates. G. Chalkboard Laminates. H. Fire-Rated Decorative Laminates. I. Compact Laminates. J. Chemical-Resistant Decorative Laminates. K. High Wear Decorative Laminates. L. Cabinet Liners. M. Phenolic Backer Sheets. Section Decorative Plastic Laminate

61 Guide Specification N. Decorative Edges and Edgeband. O. Accessory Materials RELATED REQUIREMENTS EDITING NOTE: Section listings below are common references and based on the broadly accepted CSI MasterFormat for Section numbers and titles. Revise to suit requirements for particular project. A. Section Submittals. B. Section Plastic-Laminate-Clad Architectural Cabinets. C. Section Plastic-Laminate-Clad Wood Paneling. D. Section Plastic-Laminate-Faced Wood Doors. E. Section Plastic-Laminate-Clad Toilet Compartments. F. Section Kitchen Casework. G. Section Plastic-Laminate-Clad Countertops REFERENCES EDITING NOTE: Revise Reference Standards to suit Project requirements. A. Reference Standards: 1. ASTM E 84: Standard Test Method for Surface Burning Characteristics of Building Materials. 2. ASTM E 162: Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source. 3. ASTM E 662: Standard Test Method for Specific Optical Density of Smoke Generated by Solid Materials. 4. AWI: Architectural Woodwork Institute. 5. AWS: Architectural Woodwork Standards. 6. FSC: Forest Stewardship Council. 7. IMO: International Maritime Organization. 8. IMO FTP: International Code for Application of Fire Test Procedures. 9. IMO FTP Code Part 2: Smoke and Density Test. 10. IMO FTP Code Part 5: Test for Surface Flammability. 11. ISO: International Organization for Standardization. 12. ISO 9001: Quality Management Systems. 13. ISO 14001: Environmental Management Systems. 14. KCMA A161.1: Performance & Construction Standard for Kitchen and Vanity Cabinets. 15. LEED: Leadership in Energy and Environmental Design. 16. NEMA LD-3: High Pressure Decorative Laminates. 17. NFPA 101: Life Safety Code. 18. NSF 35: High Pressure Decorative Laminates for Surfacing Food Service Equipment. 19. OHSAS: Occupational Health and Safety Assessment Series. 20. OHSAS 18001: Occupational Health and Safety Management Systems. Section Decorative Plastic Laminate

62 Guide Specification 1.04 SUBMITTALS 21. SCAQMD Rule 1168: Adhesive and Sealant Applications. 22. SCS: SCS Global Services. 23. UL 723: Test for Surface Burning Characteristics of Building Materials. 24. UL 2818: GREENGUARD Certification Program for Chemical Emissions for Building Materials, Finishes and Furnishings. A. Submit under provisions of Section Submittals. B. Product Data: Submit the following: 1. Product data for each specified product. Include manufacturer s technical data sheets and published instruction instructions. 2. Safety Data Sheets (SDS). C. Shop Drawings: Fully dimensioned shop drawings showing layouts and components, including edge conditions, joinery, terminating conditions, substrate construction, and cutouts and holes. Include elevations, section details, and large scale details. Indicate color, pattern, and finish selections. D. Samples: Selection and verification samples for each color, pattern, and finish required. E. Quality Assurance Submittals: 1. Test Reports: Certified test reports showing compliance with specified performance characteristics and physical properties, if required. 2. LEED Submittals: Applicable LEED documentation for potential credits specified in this Section. F. Maintenance Data: Manufacturer s published maintenance manual with closeout submittals REGULATORY REQUIREMENTS A. Adhesives, Sealants, and Sealant Primers: 1. SCAQMD (South Coast Air Quality Management District) Rule 1168 for VOC content. 2. Ozone Transport Commission (OTC) model Rule for Adhesives and Sealants QUALITY ASSURANCE A. Qualifications: 1. Manufacturer Qualifications: Manufacturer producing products in an ISO 9001, ISO 14001, and OHSAS certified facility. 2. Fabricator Qualifications: Minimum of three years documented experience in fabricating decorative plastic laminates similar in scope and complexity of this Project. 3. Installer Qualifications: Minimum of three years documented installation experience for projects similar in scope and complexity to this Project. [Installer shall be the fabricator]. Section Decorative Plastic Laminate

63 Guide Specification EDITING NOTE: Following two LEED paragraphs list potential credits according to LEED 2009 for New Construction & Major Renovations (LEED-NC) and LEED 2009 for Commercial Interiors (LEED-CI). Coordinate with designated Project LEED AP for credits applicable to Project. B. LEED 2009 rating system potential credits for plastic laminate: 1. [LEED-NC] [LEED-CI] MR Credit 4 - Recycled Content. 2. [LEED-NC] [LEED-CI] MR Credit 5 - Regional Materials. 3. [LEED-NC] [LEED-CI] MR Credit 6 - Rapidly Renewable Content. 4. [LEED-NC] [LEED-CI] MR Credit 7 - Certified Wood. 5. [LEED-NC] [LEED-CI] IEQ Credit Low-Emitting Materials - Composite Wood and Agrifiber Products. 6. LEED-CI IEQ Credit Low-Emitting Materials, Systems Furniture and Seating. C. LEED 2009 rating system potential credits for Wilsonart Adhesives: 1. [LEED-NC] [LEED-CI] IEQ Credit Construction Indoor Air Quality Management Plan - Before Occupancy. 2. [LEED-NC] [LEED-CI] IEQ Credit 4.1- Low Emitting Materials - Adhesives and Sealants. 3. [LEED-NC] [LEED-CI] IEQ Credit 4.4 Low-Emitting Materials - Composite Wood and Agrifiber Products. 4. LEED-CI IEQ Credit Low-Emitting Materials, Systems Furniture and Seating. D. Mock-Up: EDITING NOTE: Select mock-up size option. Delete entire paragraph if mock-up is not a Project requirement. 1. Install at Project site using acceptable products and manufacturer approved installation methods. Obtain Architect s acceptance for color, pattern, finish, fabrication, and installation standards. 2. Mock-Up Size: [ ] by [ ]. 3. Mock-Up Size: Indicated on Drawings. 4. Mock-Up Location: [Indicated on Drawings] [As directed by Architect]. 5. Maintain mock-up during construction for fabrication and installation comparison. If required, remove and legally dispose of mock-up when no longer required. 6. Incorporation: If permitted by Architect, mock-up may be incorporated into as part of the completed Work DELIVERY, STORAGE, AND HANDLING A. Storage and Protection: Store plastic laminate materials protected from exposure to harmful weather conditions, at temperature and humidity conditions recommended by manufacturer. Store sheet materials flat on pallets or similar rack-type storage to preclude damage. Section Decorative Plastic Laminate

64 Guide Specification 1.08 PROJECT CONDITIONS A. Environmental Requirements: Ensure appropriate acclimatization between plastic laminate and substrate prior to fabrication. Condition plastic laminate and substrate surfaces in the same environment for 48 hours prior to fabrication. Condition at approximately 75 deg F (24 deg C) and 45 percent to 55 percent relative humidity. 1. Adhesive: For best results, apply adhesives at temperatures at or above 65 deg F (18 deg F). B. Field Measurements: Verify actual measurements and openings by field measurements before fabrication; show recorded measurements on shop drawings. Coordinate field measurements and fabrication schedule with construction progress to avoid construction delays. PART 2 - PRODUCTS WILSONART CONTACT INFORMATION: Wilsonart, 2400 Wilson Place, Temple, TX Tel , Toll-Free , Fax Website: MANUFACTURER A. Basis of Design: Wilsonart. EDITING NOTE: Refer to the Laminate Design Detail Page on the Wilsonart website for complete information on laminate properties, including applicable sustainable design conformance standards, compliance with additional standards, physical performance properties, and available sheet sizes LAMINATE PROPERTIES A. Laminate Composition: Decorative surface papers impregnated with melamine resins and pressed over kraft paper core sheets impregnated with phenolic resin. Sheets then bonded together under pressures greater than 1,000 lbs. per sq. in. and high temperatures approaching 300 deg F (149 deg C). Finished sheets trimmed and backs sanded to facilitate bonding to substrate. B. Sustainable Design Conformance Standards: 1. UL 2818 GREENGUARD Gold Certified. 2. SCS Certified Indoor Air Quality Advantage Gold Certified. 3. SCS Chain of Custody Certified for FSC Mix, FSC Controlled Wood. 4. SCS Recycled Content Certified. Section Decorative Plastic Laminate

65 Guide Specification EDITING NOTE: Refer to the Laminate Design Detail Page on the Wilsonart website for comprehensive information regarding surface burning characteristics and classifications of Wilsonart decorative plastic laminate products. C. Surface Burning Characteristics: 1. Test Standards: ASTM E 84, ASTM E 162, ASTM E 662, IMO FTP Code Part 2 and Part 5, and UL Interior Finish Classification, Fire-Rated Laminate: Class A according to NFPA 101. Flame spread less than 25 and Smoke Developed less than 450. EDITING NOTE: Should laminate surfaces be installed in areas subject to food contact, Wilsonart offers a wide range of laminate options, including Standard, Fire-Rated, High Wear, and High Definition. Refer to Laminate Design Detail Page on the Wilsonart website for additional information. D. Surfaces Subject to Food Contact: Comply with NSF Standard STANDARD DECORATIVE LAMINATES A. Product: Wilsonart Laminate. EDITING NOTE: All standard laminates with premium finishes can be manufactured with AEON Enhanced Performance Technology. If AEON not required, delete the following paragraph. B. Enhanced Laminate Performance: Fabricate laminate with AEON Enhanced Performance Technology for increased surface wear resistance and surface abrasion. C. General Purpose Laminate Product: Wilsonart Type Sheet Thickness: inch nominal. 2. Laminate Conformance Standard: NEMA LD 3, Grade HGS. 3. Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish are not specified above, delete and select one of the following options. 4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 5. Color, Pattern, and Finish: Indicated on Drawings. 6. Color, Pattern, and Finish: Selected from manufacturer's full range of available selections. D. Vertical Surface Laminate Product: Wilsonart Type Sheet Thickness: inch nominal. 2. Laminate Conformance Standard: NEMA LD 3, Grades VGS and VGP. 3. Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish are not specified above, delete and select one of the following options. 4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 5. Color, Pattern, and Finish: Indicated on Drawings. Section Decorative Plastic Laminate

66 Guide Specification 6. Color, Pattern, and Finish: Selected from manufacturer's full range of available selections. E. Postforming Laminate Product: Wilsonart Type Sheet Thickness: inch nominal. 2. Laminate Conformance Standard: NEMA LD 3, Grade HGP. 3. Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish are not specified above, delete and select one of the following options. 4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 5. Color, Pattern, and Finish: Indicated on Drawings. 6. Color, Pattern, and Finish: Selected from manufacturer s full range of available selections HIGH DEFINITION LAMINATES A. Product: Wilsonart HD High Definition Laminate, Type 376. EDITING NOTE: All High Definition laminates with premium finishes are manufactured with AEON Enhanced Performance Technology. B. Enhanced Laminate Performance: Fabricate laminate with AEON Enhanced Performance Technology for increased surface wear resistance and surface abrasion. C. Sheet Thickness: inch nominal. D. Laminate Conformance Standard: NEMA LD 3, Grade HGP. E. Finish: [Mirage -35] [Facet -45] [Glaze -55]. F. Color and Pattern: [ ]. EDITING NOTE: If color and pattern are not specified above, delete and select one of the following options. G. Color and Pattern: Specified in SCHEDULE Article of this Section. H. Color and Pattern: Indicated on Drawings. I. Color and Pattern: Selected from manufacturer s full range of available selections SOLICOR LAMINATES A. Product: Wilsonart Solicor Laminate, Type 160. Color through the core. B. Sheet Thickness: inch nominal. C. Laminate Conformance Standard: NEMA LD 3. D. Color, Pattern, and Finish: [D354 Designer White, Matte Finish -60] [D354 Designer White, High Gloss Finish -01] [D427 Linen, Matte Finish -60] [D427 Linen, High Gloss Finish -01] [4925 Calcutta Marble, Fine Velvet Texture Finish -38]. Section Decorative Plastic Laminate

67 Guide Specification 2.06 x YOU (WxY) LAMINATES EDITING NOTE: Wilsonart x You creates a unique sheet of laminate from your digital artwork. Available in a range of sizes and product types, this process enables designers to create a custom laminate with no minimum order. For file formats and other specifications, visit us online. A. Product: Wilsonart x You Laminate. EDITING NOTE: Not all finishes are available with AEON Enhanced Performance Technology. If AEON not required, delete the following paragraph. B. Enhanced Laminate Performance: Laminate with AEON Enhanced Performance Technology for increased surface wear resistance and surface abrasion performance. C. General Purpose Type: [Silk-Screen Process - Wilsonart Type 173 ] [Graphic Image Process - Wilsonart Type 174 ]. 1. Sheet Thickness: inch nominal. 2. Laminate Conformance Standard: NEMA LD 3, Grade HGS. 3. Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish are not specified in the subparagraph above, delete and select one of the following subparagraphs. 4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 5. Color, Pattern, and Finish: Indicated on Drawings. 6. Color, Pattern, and Finish: Selected from manufacturer's full range of available selections. D. Vertical Surface Type: [Silk-Screen Process - Wilsonart Type 363 ] [Graphic Image Process - Wilsonart Type 364 ]. 1. Sheet Thickness: inch nominal. 2. Laminate Conformance Standard: NEMA LD 3, Grade VGP. 3. Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish not specified above, delete and select one of the following options. 4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 5. Color, Pattern, and Finish: Indicated on Drawings. 6. Color, Pattern, and Finish: Selected from manufacturer s full range of available selections. E. Postforming Type: [ Wilsonart Type 374 ]. 1. Sheet Thickness: inch nominal. 2. Laminate Conformance Standard: NEMA LD 3, Grade HGP. 3. Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish are not specified in the subparagraph above, delete and select one of the following subparagraphs. Section Decorative Plastic Laminate

68 Guide Specification 4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 5. Color, Pattern, and Finish: Indicated on Drawings. 6. Color, Pattern, and Finish: Selected from manufacturer's full range of available selections VIRTUAL DESIGN LIBRARY (VDL) LAMINATES EDITING NOTE: Reach beyond the wallboard with Wilsonart s Virtual Design Library. Wilsonart understands that design should not be limited by pegs on a board, links in a chain, or space on a shelf. From photorealistic imagery to abstract and artistic graphics, our online Virtual Design Library offers a growing selection of exclusive laminate patterns to fit your needs. This ever-growing collection offers hundreds of additional designs online. A. Product: Wilsonart Virtual Design Library Laminate. EDITING NOTE: Not all finishes are available with AEON Enhanced Performance Technology. If AEON not required, delete the following paragraph. B. Enhanced Laminate Performance: Laminate with AEON Enhanced Performance Technology for increased surface wear resistance and surface abrasion performance. C. Vertical Surface Type: [ Wilsonart Type 362 ] [ Wilsonart Type 367 ]. 1. Sheet Thickness: inch nominal. 2. Laminate Conformance Standard: NEMA LD 3, Grade VGP. 3. Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish not specified above, delete and select one of the following options. 4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 5. Color, Pattern, and Finish: Indicated on Drawings. 6. Color, Pattern, and Finish: Selected from manufacturer s full range of available selections. D. Postforming Type: [ Wilsonart Type 372 ] [ Wilsonart Type 377 ]. 1. Sheet Thickness: inch nominal. 2. Laminate Conformance Standard: NEMA LD 3, Grade HGP. 3. Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish are not specified in the subparagraph above, delete and select one of the following subparagraphs. 4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 5. Color, Pattern, and Finish: Indicated on Drawings. 6. Color, Pattern, and Finish: Selected from manufacturer's full range of available selections [MARKERBOARD] [AND] [CHALKBOARD] LAMINATES EDITING NOTE: Select type(s) required for Project. A. Markerboard Product: Wilsonart Markerboard Laminate. Section Decorative Plastic Laminate

69 Guide Specification B. Markerboard Laminate - Horizontal Grade Type: Wilsonart Type Sheet Thickness: inch nominal. 2. Conformance Standard: NEMA LD 3, Grade HGS. 3. Color and Finish: [1572, Antique White, Gloss -09 Finish] [1573, Frosty White, Gloss -09 Finish] [1595, Black, Gloss -09 Finish]. EDITING NOTE: If color and finish is not specified above, delete and select from one of the following options. 4. Colors: Specified in SCHEDULE Article of this Section. 5. Colors: Indicated on Drawings. 6. Colors: Selected from manufacturer's full range of available selections. C. Chalkboard Product: Wilsonart Chalkboard Laminate. D. Chalkboard Laminate - Horizontal Grade Type: Wilsonart Type Sheet Thickness: inch nominal. 2. Conformance Standard: NEMA LD 3, Grade HGS. 3. Color and Finish: 4623, Graphite Nebula, Fine Velvet Textured Finish FIRE-RATED DECORATIVE LAMINATES A. Product: Wilsonart Fire-Rated Laminate. Manufactured with a fire-retardant-treated kraft phenolic core. Class A rated according to NFPA 101. B. General Purpose Type: Wilsonart Type Sheet Thickness: inch nominal. 2. Laminate Conformance Standard: NEMA LD 3, Grade VGF. 3. Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish selections are not specified above, delete and select from one of the following options. 4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 5. Color, Pattern, and Finish: Indicated on Drawings. 6. Color, Pattern, and Finish: Selected from manufacturer's full range of available selections. C. General Purpose Type: Wilsonart Type Sheet Thickness: inch nominal. 2. Laminate Conformance Standard: NEMA LD 3, Grade HGF. 3. Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish selections are not specified above, delete and select from one of the following options. 4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 5. Color, Pattern, and Finish: Indicated on Drawings. 6. Color, Pattern, and Finish: Selected from manufacturer's full range of available selections. Section Decorative Plastic Laminate

70 Guide Specification D. General Purpose Type: Wilsonart Type Sheet Thickness: inch nominal. 2. Laminate Conformance Standard: NEMA LD 3, Grade SGF. 3. Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish selections are not specified above, delete and select from one of the following options. 4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 5. Color, Pattern, and Finish: Indicated on Drawings. 6. Color, Pattern, and Finish: Selected from manufacturer's full range of available selections COMPACT LAMINATES EDITING NOTE: Compact Laminates are high performance solid composites offering superior impact resistance, fire-rated performance, and chemical/stain resistance. A. Product: Wilsonart Compact Laminate. B. Wilsonart Classic Grade : Self-supporting homogenous panels finished with melamine surface. Impact-resistant design. EDITING NOTE: Types 114 and 117 are sanded one side; remainder are doublefaced. 1. Product Type and Nominal Thickness: [Type 114; inch] [Type 514; inch] [Type 117; inch] [Type 515; inch] [Type 569; inch] [Type 571; inch] [Type 572; inch] [Type 568; inch] [Type 575; inch] [Type 590; 1.00 inch]. 2. Laminate Conformance Standard: NEMA LD 3, Grade CGS. 3. Finish: Matte Color and Pattern: [ ]. EDITING NOTE: If color and pattern selections are not specified above, delete and select from one of the following options. 5. Color and Pattern: Specified in SCHEDULE Article of this Section. 6. Color and Pattern: Indicated on Drawings. 7. Color and Pattern: Selected from manufacturer's full range of available selections. C. Wilsonart Fire-Rated Grade : For applications where fire-rated properties are required. Double-faced. Class A rated according to NFPA Product Type and Nominal Thickness: [Type 669; inch] [Type 671; inch] [Type 672; inch] [Type 668; inch] [Type 675; inch] [Type 690; 1.00 inch]. 2. Laminate Conformance Standard: NEMA LD 3, Grade CGS. 3. Finish: Matte Color and Pattern: [ ]. EDITING NOTE: If color and pattern selections are not specified above, delete and select from one of the following options. Section Decorative Plastic Laminate

71 Guide Specification 5. Color and Pattern: Specified in SCHEDULE Article of this Section. 6. Color and Pattern: Indicated on Drawings. 7. Color and Pattern: Selected from manufacturer's full range of available selections. D. Wilsonart Laboratory Grade : For applications requiring high degree of chemical and stain resistance. Double-faced. 1. Product Type and Nominal Thickness: [569-95; inch] [571-95; inch] [572-95; inch] [568-95; inch] [575-95; inch] [590-95; 1.00 inch]. 2. Laminate Conformance Standard: NEMA LD 3, Grade CGS. 3. Finish: Matte Color and Pattern: [ ]. EDITING NOTE: If color and pattern selections are not specified above, delete and select from one of the following options. 5. Color and Pattern: Specified in SCHEDULE Article of this Section. 6. Color and Pattern: Indicated on Drawings. 7. Color and Pattern: Selected from manufacturer's full range of available selections CHEMICAL-RESISTANT DECORATIVE LAMINATES A. Product: Wilsonart Chemsurf Chemical-Resistant Laminate. B. Post-Forming Type: Wilsonart Type Sheet thickness: inch nominal. 2. Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish selections are not specified above, delete and select from one of the following options. 3. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 4. Color, Pattern, and Finish: Indicated on Drawings. 5. Color, Pattern, and Finish: Selected from manufacturer's full range of available selections HIGH WEAR DECORATIVE LAMINATES A. Product: Wilsonart High Wear Laminate. EDITING NOTE: High Wear Types 107HW, 335HW, and 350HW are available as specified herein. B. General Purpose Laminate: Wilsonart Type 107HW. 1. Sheet Thickness: inch nominal. 2. Laminate Conformance Standard: NEMA LD 3, Grade HGS. 3. Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish are not specified above, delete and select one of the following options. Section Decorative Plastic Laminate

72 Guide Specification 4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 5. Color, Pattern, and Finish: Indicated on Drawings. 6. Color, Pattern, and Finish: Selected from manufacturer's full range of available selections. C. Vertical Surface Laminate: Wilsonart Type 335HW. 1. Sheet Thickness: inch nominal. 2. Laminate Conformance Standard: NEMA LD 3, Grades VGS and VGP. 3. Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish are not specified above, delete and select one of the following options. 4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 5. Color, Pattern, and Finish: Indicated on Drawings. 6. Color, Pattern, and Finish: Selected from manufacturer's full range of available selections. D. Postforming Laminate: Wilsonart Type 350HW CABINET LINERS 1. Sheet Thickness: inch nominal. 2. Laminate Conformance Standard: NEMA LD 3, Grade HGP. 3. Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish are not specified above, delete and select one of the following options. 4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 5. Color, Pattern, and Finish: Indicated on Drawings. 6. Color, Pattern, and Finish: Selected from manufacturer s full range of available selections. A. Product: Wilsonart Cabinet Liner Sheets. EDITING NOTE: Cabinet Liner Types 101, 182, and 184 are available as specified herein. B. Cabinet Liner Laminate: Wilsonart Type Sheet Thickness: inch nominal. 2. Laminate Conformance Standard: NEMA LD 3, Grade CLS. 3. Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish are not specified above, delete and select one of the following options. 4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 5. Color, Pattern, and Finish: Indicated on Drawings. 6. Color, Pattern, and Finish: Selected from manufacturer's full range of available selections. C. Cabinet Liner Laminate: Wilsonart Type Sheet Thickness: inch nominal. Section Decorative Plastic Laminate

73 Guide Specification 2. Laminate Conformance Standard: NEMA LD 3, Grade CLS. 3. Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish are not specified above, delete and select one of the following options. 4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 5. Color, Pattern, and Finish: Indicated on Drawings. 6. Color, Pattern, and Finish: Selected from manufacturer's full range of available selections. D. Cabinet Liner Laminate: Wilsonart Type Sheet Thickness: inch nominal. 2. Laminate Conformance Standard: NEMA LD 3, Grade CLS. 3. Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish are not specified above, delete and select one of the following options. 4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 5. Color, Pattern, and Finish: Indicated on Drawings. 6. Color, Pattern, and Finish: Selected from manufacturer s full range of available selections PHENOLIC BACKER SHEETS A. Product: Wilsonart Phenolic Backer Sheets. EDITING NOTE: Several types, thicknesses, and weights are available for non-fire-rated backer sheets. Refer to the Phenolic Backer Sheet Technical Data Sheet on Wilsonart B. website Non-Fire-Rated to review complete Backer list Sheet: of choices, Wilsonart including Type the [ ]. NEMA LD 3 Grade designation. 1. Sheet Thickness: [ ] inch nominal. 2. Laminate Conformance Standard: NEMA LD Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish are not specified above, delete and select one of the following options. 4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 5. Color, Pattern, and Finish: Indicated on Drawings. 6. Color, Pattern, and Finish: Selected from manufacturer's full range of available selections. B. Fire-Rated Backer Sheet: Wilsonart Type 264-FR. Use in conjunction with Wilsonart Type 604 Fire-Rated Laminate. Class A rated according to NFPA Sheet Thickness: inch nominal. 2. Laminate Conformance Standard: NEMA LD 3, Grade BKV. 3. Color: Brown (natural color). Section Decorative Plastic Laminate

74 Guide Specification C. Fire-Rated Backer Sheet: Wilsonart Type 266-FR. Use in conjunction with [ Wilsonart Type 605 Fire-Rated Laminate ] [ Wilsonart Type 607 Fire-Rated Laminate ]. Class A rated according to NFPA Sheet Thickness: inch nominal. 2. Laminate Conformance Standard: NEMA LD 3, Grade BKH. 3. Color: Brown (natural color) DECORATIVE EDGES AND EDGEBANDS A. Decorative Edge Products: Wilsonart Decorative Edges. 1. Beveled Edge, [FE Profile.] [SE Profile.] 2. Cascade Edge, [FE Profile.] [SE Profile.] 3. Crescent Edge, [FE Profile.] [SE Profile.] 4. Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish selections are not specified above, delete and select from one of the following options. 5. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 6. Color, Pattern, and Finish: Indicated on Drawings. 7. Color, Pattern, and Finish: Selected from manufacturer's full range of available selections. B. Edgeband Products: Wilsonart Edgeband. 1. Composition: ABS/PVC extruded fabrication. 2. Width: [15/16 inch] [1-5/16 inch]. 3. Thickness: Refer to Tech Data Sheet. 4. Color, Pattern, and Finish: [ ]. EDITING NOTE: If color, pattern, and finish selections are not specified above, delete and select from one of the following options. 5. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section. 6. Color, Pattern, and Finish: Indicated on Drawings. 7. Color, Pattern, and Finish: Selected from manufacturer's full range of available selections ACCESSORY MATERIALS EDITING NOTE: Select from the following edge designs. EDITING NOTE: Following contact adhesives are UL GREENGUARD Gold Certified, quality for LEED points, and comply with referenced SCAQMD and OTC regulations. For the complete line of Wilsonart Contact adhesives, refer to the Adhesives product link on the Wilsonart website. A. Contact Adhesive: 1. Product: Wilsonart 1730/1731 Low VOC Contact Adhesive. 2. Description: High solids, low VOC contact adhesive for non-postforming applications. Section Decorative Plastic Laminate

75 Guide Specification B. Contact Adhesive, Water-Based: 1. Product: Wilsonart H Description: Non-flammable low VOC water-based contact adhesive for postforming applications. EDITING NOTE: All PVA adhesives are UL GREENGUARD Gold Certified, qualify for LEED points, and comply with referenced SCAQMD and OTC regulations. Refer to the Adhesives product link on the Wilsonart website for complete list of adhesives. C. Polyvinyl Acetate (PVA) Adhesive: 1. Product: Wilsonart PVA Adhesive. 2. Description: PVA-based adhesives for bonding decorative laminate to wood substrates. Acceptable for cold press, hot press, and postforming applications. PART 3 - EXECUTION 3.01 EXAMINATION EDITING NOTE: Acceptable substrates for bonding Wilsonart Laminates are particleboard, medium density fiberboard, and plywood with one A face. Marginal substrates are steel, aluminum, fiber reinforced plastic, and plywood without A faces. Unsuitable substrates are high pressure laminate, plaster, concrete, and gypsum board. A. Examine surfaces for conditions that could adversely affect the performance of the decorative plastic laminate installation, including edge performance. B. Surfaces to be adhesively bonded shall be clean, dry and free of any dust, loose paint, wax, moisture, dirt, grease, oil, rust, or other contaminants. C. Commencement of work will constitute acceptance of existing conditions and surfaces to receive the work INSTALLATION, GENERAL A. Install materials according to referenced Specification Sections and the following conformance standards as applicable: 1. AWI AWS. 2. KCMA A B. To avoid stress cracking, do not use square-cut inside corners. All inside corners to have a minimum 1/8 inch radius and all edges routed smooth. C. Drill oversized holes for screws, bolts, and similar fasteners. Slightly countersink fasteners into face side of laminate-clad substrate. D. Use carbide-tipped saw and router blades for cutting, with high tool speed and low feed speed. Keep cutting blades sharp. Use appropriate hold-downs to prevent vibration. Section Decorative Plastic Laminate

76 Guide Specification 3.03 ADHESIVE SPRAY APPLICATIONS A. Comply with adhesive manufacturer s printed installation instructions. B. Apply contact adhesive uniformly to both surfaces and with a minimum 80 percent coverage for each surface. Apply PVA adhesive to one side with a minimum 80 percent coverage. C. Apply two coats of adhesive to porous surfaces. Provide 100 percent coverage for edges. D. Apply uniform downward pressure (30 to 40 psi minimum) across the entire bonded surface ADHESIVE BRUSH APPLICATIONS A. Comply with adhesive manufacturer s printed installation instructions. B. Apply contact adhesive uniformly to both surfaces with a brush or solvent-resistant medium nap roller; cover each surface 100 percent. Apply PVA adhesive to one side, for 100 percent coverage. C. Provide two coats of adhesive on porous surfaces. Double coat edges. D. Apply uniform downward pressure (30 to 40 psi minimum) across the entire bonded surface CLEANING AND PROTECTION A. Clean decorative plastic laminate according to manufacturer s printed care and maintenance instructions. B. Protect installed products and finish surfaces from damage during remainder of construction period SCHEDULE OPTION: Color, Pattern, and Finish Schedule may be inserted here if this option is chosen. END OF SECTION Section Decorative Plastic Laminate

77 Wilsonart Solid Surface Sinks Care & Maintenance General Cleaning We thank you for selecting Wilsonart Solid Surface sinks or lavatory bowls for your home. Providing minimal care and proper maintenance, your Wilsonart Solid Surface sink or bowl will look and perform for many years to come. Wilsonart Solid Surface sinks and bowls are composed of a proprietary mixture of resins and minerals. Wilsonart Solid Surface sinks and bowls are completely homogeneous and are very hygienic, highly stain resistant, and extremely durable. The full-toned color has a consistent, uniform pigment throughout the thickness of each bowl. Its luxurious matte finish enables the sink to keep its beauty for years with minimum day to day care and maintenance. There may be a slight variation in color when sinks and lavatories are bonded to a similar Wilsonart Solid Surface solid color panel. This is considered normal and not a color issue. Wilsonart Solid Surface sinks and bowls may be cleaned with warm water and mild soaps, such as those used for hands and dishes. Mild abrasive cleaners such as Bon-ami, Comet or Soft Scrub also work very well. For stubborn residue, apply one of the mild abrasives cleaners above and with a green Scotch- Brite pad, buff in a circular motion over the entire sink to blend finish. Simple Precautions Run warm water if pouring boiling water in sink Allow cookware to cool before placing in sink Do not expose the surface to harsh chemicals, such as paint remover, turpentine, nail polish remover (acetone) or stove and drain cleaners. If the chemicals come in contact with the surface, immediately wash them off with water, using appropriate safety measures to avoid injury

78

79

80 Care & Maintenance Wilsonart Laminate & Care Maintenance Your decision to purchase Wilsonart Laminate will bring you years of quality performance. Everyday cleaning of our products is as simple as a quick wipe with a damp sponge. All resist muddy fingerprints, coffee spills and so much more. Be sure to read and follow the recommended care and cleaning procedures. Routine Care To clean the surface, use a damp cloth or sponge and a mild soap or detergent. Rinse thoroughly with warm water and wipe dry. Difficult stains such as coffee or tea can be removed using a mild household cleaner/detergent and a soft bristled brush, repeating as necessary. If a stain persists, use a paste of baking soda and water and apply with a soft bristled brush. Light scrubbing for 10 to 20 strokes should remove most stains. Although baking soda is a low abrasive, excessive scrubbing or exerting too much force could damage the decorative surface, especially if it has a gloss finish. Stubborn stains that resist any of the above cleaning methods may require the use of undiluted household bleach or nail polish remover. Apply the bleach or nail polish remover to the stain and let stand no longer than two minutes. Rinse thoroughly with warm water and wipe dry. This step may be repeated if the stain appears to be going away and the color of the laminate has not been affected. WARNING: Prolonged exposure of the laminate surface to bleach will cause discoloration. Hot pans and heat-producing appliances (such as electric skillets), when set directly upon countertops, can mar the product s beauty. Always use a heat shield, hot pad or trivet. A Few Notes of Caution Acidic or abrasive cleaners can damage laminate surfaces; do not use them. Drain cleaners containing lye will permanently damage any Wilsonart Laminate surface. If you spill a drain cleaner, wipe it up immediately and rinse several times with water. Hair, textile and food dyes can cause permanent stains. If dye should happen to spill, wipe it up immediately with dishwashing detergent or an all-purpose cleaner. Never place pots or dishes directly from the oven or burner on an unprotected laminate surface; such extreme heat can cause cracking or blistering. Do not work with oven cleaners on an unprotected countertop. Wipe spills away promptly and rinse several times with water. Rust removers contain harsh chemicals which will quickly cause permanent damage. If a spill occurs, wipe off all residue immediately, wash thoroughly with soapy water and rinse several times. Steel wool and other abrasive pads will damage Wilsonart Laminate. Don t use them for cleaning and don t store steel wool pads on your countertop; the metal can rust and leave stains. Toilet bowl cleaners contain harsh chemicals that can cause permanent damage. If spills occur, wipe up immediately, wash surface with soapy water and rinse several times. Recommended Household Cleaners Windex Glass Plus Fantastik Mr. Clean Formula 409 Isopropyl Alchol (Isopropanol) *Prolonged exposure to bleach will cause discoloration. When cleaning Wilsonart Laminate, DO NOT use products that contain the following ingredients: Chemical Ingredient Hydrochloric Acid Sulfuric Acid Hydrofluoric Acid Phosphoric Acid Sodium Hydroxide Pumice (abrasive) BR0551 Synonymous Names Muriatic Acid Hydrogen Chloride Oleic Acid Oil of Vitriol Oleum Rust Remover Rust Remover Caustic Soda Caustic Lye Soda Lye N/A Corporate Headquarters 2400 Wilson Place P.O. Box 6110 Temple, TX Toll Free: (800) Mon.-Fri. 8:00 am - 5:00 pm CST Phone (254) Fax (254) (24 Hours) Internet: Wilsonart LLC

81 Para Mantener Y Cuidar Laminados Wilsonart Consejos especiales Productos Recomendados Para Limpieza Para limpiar la superficie use liquido limpiavajilla, o un detergente suave y agua, usando un paño suave o una esponja. Con manchas difíceles como de café o té, use un limpiador o detergente suave y un cepillo de cerdas suaves y repita el proceso si es necesario. Si aun así la mancha no desaparece, use una pasta de bicarbonato de sodio y agua y aplíquela con un cepillo de cerdas suaves. En la mayoria de los casos, frotar suavemente 10 a 20 veces debera ser suficiente para hacer desaparecer la mancha. Aunque el bicarbonato de sodio no es muy abrasivo, frotarlo repetidamente o aplicar mucha fuerza puede dañar la superficie, especialmente en caso de laminados con acabado brillante. En caso de manchas rebeldes que no cedan a los métodos anteriores, haga una pasta con blanqueador sin diluir o quitaesmalte. Aplíquelo sobre la mancha, y déjelo no más de dos minutos. Enjuague varias veces con agua tibia y seque con un paño suave. Si la mancha comienza a desaparecer y el color del laminado no se ve afectado, repita los pasos anteriores. ADVERTENCIA: Exponer la superficie del laminado al blanqueador por tiempo prolongado, ocasionará perdida del color. Las sartenes calientes y los aparatos eléctricos que producen calor (como las hornillas eléctricas), cuando se las coloca directamente en la superficie, pueden dañar la belleza del laminado. Siempre utilice un aislador, un platillo, o algo para proteger la superficie. Siempre enjuague la superficie del laminado despues de limpiar. No enjuagar después de limpiar es la causa más común de daño al laminado. Aun una pequeña cantidad de limpiador que quede sobre la superficie, se puede reactivar por la humedad de las tazas o platos, dejando marcas permanentes en el material. Enjuague cuidadosamente con agua limpia y un paño limpio cada vez que aplique algún tipo de limpiador. Recuerde usar una tabla de cortar. El filo de los cuchillos puede dañar la superficie de los laminados Wilsonart, afectando su belleza y disminuyendo su resistencia a las manchas y al desgaste. Los laminados Wilsonart se usan en ocasiones en lugares que solo requieren remoci6n ocasional del polvo. La bella apariencia de estas superficies se puede mantener con más facilidad usando un aerosol para muebles sin aceite. (Recuerde remover el lustramuebles varias veces en el año para evitar que se acumule). El lustramuebles tambien ayuda a disimular las rayaduras ligeras. Algunas precauciones No use limpiadores muy ácidos o abrasivos. Pueden dañar el laminado. Los limpiadores de cañerías con lejía (soda caústica), dañarán permanentemente cualquier superficie Wilsonart. Si llega a salpicar uno de estos limpiadores, quítelo de inmediato y enjuague varias veces con agua limpia. Las tinturas de cabello, textiles y de alimentos pueden dejar manchas permanentes. Si salpican tinturas, retírelas de inmediato con detergente limpiavajilla o con limpiador general. Nunca coloque ollas o platos sacados directamente del horno o calentador sobre una superficie laminada no protegida: el calor extremo puede producir grietas o ampollas en la superficie. No coloque limpiahornos sobre una cubierta no protegida. Retire de inmediato las salpicaduras y enjuague varias veces con agua limpia. Los removedores de óxido contienen potentes agentes químicos que rápidamente causarán daños permanentes. Si hay un derrame, retire inmediatamente los residuos, lave cuidadosamente con agua jabonosa y enjuague varias veces. La viruta de acero daña los laminados Wilsonart. No la use para limpiar, y no la deje sobre la superficie, el metal puede oxidarse y dejar at manchas. Los limpiadores de inodoros contienen potentes agentes que pueden causar daños permanentes. Si se derraman, retírelos de inmediato, lave la superficie con agua jabonosa y enjuague varias veces. Windex Glass Plus Fantastik Mr. Clean Formula 409 Isopropyl Alchol (Isopropanol) *La exposición prolongada a un decolorante/blanqueador causará descoloración. Cuando limpie laminados Wilsonart, o pisos no utillice productos quo contengan los siguientes ingredientes quimicos: Ingrediente Químico Ácido Clorhídrico Ácido Sulfúrico Ácido Fluorhídrico Ácido Fosfórico Hidróxido de Sodio Hidróxido de Potasio Pómez (abrasivo) Sinónimos Frecuentes Ácido Muriático Cloro Furfural Vitriolo Protector limpiador de hierro Protector limpiador de hierro/antióxido Soda Cáustica Soda Soda Cáustica Polvo de Piedra Pómez Piedra China

82 CORTEGA Up to 43% armstrong.com/greengenie LEED Credits Square Lay-in & Tegular Energy Waste Mgmt LEED for Schools Recycled Local Renewable Daylight Content Materials Materials & Views medium texture Acoustics Low Emitting or CHPS Location Dependent $$$$$ Colors Key Selection Attributes Economical Non-directional visual reduces installation time and scrap White (WH) Typical Applications Tech Black (BL) Item 769 Colored ceilings are dye-lotted and should be segregated by dye lot. Do not mix. Utility rooms Discount stores Cortega Angled Tegular with Prelude 15/16" Exposed Tee grid (Pg. 215) Performance Selection Visual Selection Dots represent highest level of performance. Grid UL Classified Drawings Acoustics Fire Light Sag Cat. pgs. Edge Item Dimensions NRC CAC Rating Reflect Resist Profile No. CORTEGA Square Lay-in AntiDurable Microbial Recycle Program or armstrong. com/catdwg M 15/16" 1 Square Lay-in 2' x 2' x 5/8" Class A 0.82 Standard Standard Yes 600 x 600 x 15mm ' x15/16" 2' xangled 5/8" Fire Guard 0.82 Standard Standard Ultima Plank ShipLap Square Lay-in 9/16" Angled Tegular Tegular Ultima Plank ShipLap Long Edge Detail K2C2 Short 824M 600 x 600 x 15mm ' x 4' x 5/8" Class A 0.82 Standard Standard 769M 600 x 1200 x 15mm Ultima Plank ShipLap Ultima Plank ShipLap Square Lay-in 9/16" Angled Tegular 15/16" Angled Tegular ShortGuard ' x 4' x 5/8" Long Edge Detail K2C2Fire 0.82 Standard Standard 823M 600 x 1200 x 15mm 9/16" Chamfered Tegular Tegular Ultima Plank ShipLap Ultima Plank ShipLap 15/16 Classic Step Tegular 15/16" Chamford 850 Tegular 2' Classic x 4' Step x 5/8" N/A N/A Fire Guard N/A N/A Standard Cirrus Profiles Chamfered ~8-ID (99) (drw 10) Long Edge Detail Beveled Tegular Short Cirrus Profiles Chamfered " x 5' x 5/8" Class A 0.82 Standard Standard 773M 500Classic x 1500 x 15mm 9/16" Chamfered Tegular Step Tegular Ultima Plank ShipLap Ultima Plank ShipLap 15/16 Classic Step Tegular 15/16" Chamford Tegular Cirrus Profiles Chamfered Long Edge Detail ~8-ID (99) (drw 10) Beveled Tegular Short Cirrus Profiles Chamfered ' x 5' x 5/8" Class A 0.82 Standard Standard 772M 600 x 1500 x 15mm CORTEGA Tegular 9/16" Beveled Tegular 15/16" Beveled Tegular 15/16" Beveled Tegular 704 9/16" Beveled Tegular6 15/16" Angled Tegular 9/16" Angled Tegular 15/16" Angled Tegular6 9/16" Square Cut Tegular 704M A M i n eral F i b er ed Tegular Linear and ner B Linear Corner quares) B C and D Cubic 2' Plank x 2'ShipLap x 5/8" Fire Guard 0.82 Standard Standard Ultima Plank ShipLap 816 Ultima Long Edge Detail K2C2 Short Concealed Linear Cubic A B C D Square Edge K4C4 15/16" Vector /16" Vector C & DA 703 2' x Beveled 4' x Crossgate 5/8" 35 Class 0.82 Standard Standard A B C D 1200 x 15mm 9/16" Wrapped Linear and Concealed Linear Cubic Square Edge K4C4 Beveled Crossgate Mixed Corner B (Flumes, Graphis Linear Corner 15/16" & Dots & Squares) Classic Step Tegular Ultima Plank ShipLap Ultima Plank ShipLap 15/16" Chamford Tegular Long Edge Detail Beveled Tegular Short Cirrus Profiles Chamfered Suspension Systems Prelude Concealed Beveled K4C4 9/16" Wrapped Tegular Graphis Wrapped Linear Cut Tegular 15/16" Square 9/16" Wrapped 2' x9/16" 2' xsquare 5/8" 0.55Tegular 33 Class A Tegular 0.82 Standard Standard Graphis Wrapped Linear 600 x 600 x 15mm 9/16" Wrapped Linear and Mixed Corner B 6 (Flumes, Graphis Linear Corner 703M 600 x & Dots & Squares) red Tegular Chamfered 15/16" Square Tegular ' x 2' x 5/8" Class A 0.82 Standard Standard and Cubic 2195M 600 x 600 x 15mm 9/16" 31-34, 54 Beveled Tegular ay-in 4C4 Recycled Content: Tongue and Groove Prelude XL Fire 9/16"Guard Cubic Graphis NeoCubic A B 15/16" Vector 9/16" C D 15/16" Vector C & D 15/16 Classic Step Tegular ~8-ID (99) (drw 10) Interlude Concealed Soft Look Radiused Tegular Silhouette Bolt-Slot Sonata Suprafine Trimlok Screw-Slot Item 2195-CAC 31 or 9/16" Silhouette or Trimlok P h y s i c a l D9/16" a tsquare ak4c4cut Tegular Beveled 15/16" Beveled Tegular Concealed Tongue and Square Groove Tegular 15/16" Material Wet-formed mineral fiber Surface Finish Factory-applied latex paint 9/16" Flush Tegular Ledges A 15/16" Flush Tegular B Ledges Fire Performance ASTM E84 and CAN/ULC S102 surface burning Concealed Linear Cubic A B characteristics. Flame Spread or less. Square Edge K4C4 Beveled CrossgateIndex 25 15/16" Vector 9/16" Flush 15/16" Flush Tegular Smoke Developed Index 50Tegular or less. (UL labeled) Ledges Ledges Fire Guard : A fire resistive ceiling when used in applicable UL assemblies ASTM E1264 Classification Type III, Form 2, Pattern C D 153 Tongue and Groove SM Cubic Graphis 9/16" 9/16" Tegular 9/16"Wrapped Cubic Graphis Graphis NeoCubic Wrapped Linear Concealed Soft Look Radiused Tegular VOC/Formaldehyde Emissions and Cubic Meets CA Dept. of Health Services Standard Practice for the testing of VOC Emissions and is listed on CHPS High Performance Products Database for Low-Emitting Materials. InsulationD Value C 2195, 704, 816, 703 R Factor 1.6 (BTU units) RC Factor D 0.28 (Watts units) 15/16" C & 769, D 770,Vector 772, 773, 823, 824 R Factor 1.5 (BTU units) R Factor 0.26 (Watts units) Warranty Information Details in back of catalog or at armstrong.com/warranty Application Considerations Tech Black products should be handled with gloves to prevent marking with fingerprints. Objectionable surface dust may occur with frequent handling of Tech Black products. In these situations, Tech Black products are not recommended for bright open spaces. Item 850 Fire Protection Board available for plenum use in fire-rated assembly for tenting light fixtures. Weight; Square Feet/Carton lbs/sf; 96 SF/ctn 704, lbs/sf; 64 SF/ctn 772, lbs/sf; 100 SF/ctn lbs/sf; 80 SF/ctn lbs/sf; 64 SF/ctn lbs/sf; 48 SF/ctn 823, lbs/sf; 64 SF/ctn lbs/sf; 64 SF/ctn Concealed TechLine NeoCubic / ARmSTRONG LEED is a registered trademark of the U.S. Green Building Council Soft Look Radiused Tegular armstrong.com/ceilings (search: cortega) All other trademarks used herein are the property of AWI Licensing Company and/or its affiliates CS AWI Licensing Company Printed in the United States of America

83 Recycled Content: 30% PRELUDE XL 15/16" Exposed Tee System Key Selection Attributes Seismic Rx Suspension System saves time and money; ICC-ES approach to installations (ESR-1308) PeakForm patented profile increases strength and stability for improved performance during installation SuperLock 2 main beam clip is engineered for a strong, secure connection and fast accurate alignment confirmed with an audible click; easy to remove and relocate Hot dipped galvanized coating inhibits red rusting better than electrogalvanized or painted systems Rotary-stitched during manufacture by a patented method for additional torsional strength and extra stability during installation XL 2 staked-on stab end detail provides tight, secure locked connection; easy to remove, reuse and relocate State-of-the-art expansion relief on Fire Guard options; provides greater strength and prohibits distortion of grid face during installation 10-year limited warranty; 30-year with HumiGuard Plus Typical Applications Retail Education Offices Hospitality Fire Guard applications based on building construction and local fire code requirements Color Selection WH - White CR - Cream HA - Haze VA - Vanilla CM - Camel YS - Oyster PL - Platinum AD - Adobe AR - Brass AM - Mirror BL - Tech Black SG - Silver Grey MY - Gun Metal Grey ST - Slate WK - Wolf WA - White Aluminum NA - Natural Aluminum SA - Silver Satin HDC - Hot Dipped Clear Coat PW - Pewter BZ - Bronze SL - Silver Product Description Materials A. General: ASTM C635 (Intermediate-duty) (Heavy-duty) main beam classification, commercial-quality hot dipped galvanized steel. Exposed surfaces chemically cleansed, galvanized steel or aluminum capping prefinished in baked polyester paint or annodized. B. Components: 1. Main Beams: Double-web construction, web height 1-11/16 with peaked roof top bulb and 15/16 bottom flange with prefinished steel or aluminum capping*; one fire expansion relief per fire rated main beam. * NOTE: Fire Guard items available in steel capping only. 2A. Cross Tee: Double-web construction, web height 1-11/16, 15/16 bottom flange with prefinished steel or aluminum capping and override at each end. Staked-on end detail allows easy cross tee removal and remounting. 2B. Cross Tee: Double-web construction, web height 1-1/2, 15/16 bottom flange with prefinished steel or aluminum capping and override at each end. Staked-on end detail allows easy cross tee removal and remounting. 2C. Cross Tee: Double-web construction, web height 1-3/8, 15/16 bottom flange with prefinished steel or aluminum capping and override at each end. Staked-on end detail allows easy cross tee removal and remounting. 2D. Cross Tee: Double-web construction, web height 1-3/16, 15/16 bottom flange with prefinished steel cap and override at each end. Staked-on end detail allows easy cross tee removal and remounting. Wall Moldings: 3A. Angle molding: hemmed with prefinished exposed flanges 3B. Shadow molding: hemmed with prefinished exposed flanges 3C. Shadow Molding: (Compatible with Seismic Rx and BERC 2) 3D. Channel molding: hemmed with prefinished exposed flanges 7300 (144, routs 6 OC, Intermediate-duty) 7301 (144, routs 6 OC, Heavy-duty) 7302 (120, routs 6 OC, Intermediate-duty) 7305 (140, routs 10 OC, Intermediate-duty) (3600mm, routs 150mm OC, Intermediate-duty) Fire Guard Items 8300 (144, routs 6 OC, Intermediate-duty) 8301 (144, routs 6 OC, Heavy-duty) (3600mm, routs 150mm OC, Intermediate-duty) Other XL7340 (48, routs 12 OC) XL7341 (48, routs 12 OC) XL7330 (36 ) XL7380 (96, routs 12 OC) XL7357 (60, routs 6 OC) XL7358 (60, routs 20 OC) XL7390 (72, routs 12 OC) Fire Guard Items XL8320 (24 ) XL8340 (48, routs 12 OC) XL8341 (48, routs 12 OC) (1200mm, routs 300mm OC) Other XL7342 (48, routs 12 OC) XL7318 (12 ) XL7368 (20 ) XL7328 (24 ) XL7378 (30 ) XL7348 (48 ) (300mm, center rout) (600mm) (1200mm, center rout) Fire Guard Items XL8323 (24 ) (600mm) Other XL7148 (48, routs 12 OC) XL7128 (24 ) 2D. (A) (B) Item # Length Flange Height /8 7/ HD /8 7/8 (A) (B) (C) Item # Length Flange Height Reveal /4 15/16 1/ /16 15/16 1/ /16 15/16 3/ /16 15/16 1/2 (A) (B) (C) Item # Length Flange Height Flange /8 1-3/4 9/16 2C. 1/4" (6mm) 15/16" (24mm) 9/16" (14mm) 15/16" (24mm) 15/16" (24mm) 1/4" 15/16" (24mm) 1/4" (6mm) 3/32" (2mm) (6mm) 1-11/16" (43mm) 1/4" (6mm) B 1-11/16" (43mm) 1-3/8" (35mm) B C B 1-3/16" (30mm) C A A A 15/16" (24mm) 1/4" (6mm) 1-1/2" (38mm) Only available on 7301, XL7342, XL7328, and 7800 NOTE: Color chips included with samples of Armstrong grid. See your Armstrong representative for sample material. NOTE: Items 7305, 7302, XL7340, XL7380, XL7357, XL7358, XL7128, XL7148, XL7348, XL7330, XL7318, XL7368, XL7378, XL7390, XL8320, XL8341, XL7341 are available in white only. NOTE: 8300, XL8340 and XL8323 are available in white and black only.

84 PRELUDE XL 15/16" Exposed Tee System Physical Data Material Hot dipped galvanized steel Surface Finish Baked polyester paint or anodized Face Dimension 15/16 Profile Exposed tee Cross Tee/Main Beam Interface Override End Detail Main Beam: Staked-on clip XL Cross Tee: Staked-on clip Duty Classification Intermediate or Heavy-duty Main Beam Load Test Data HANGER SPACING MAIN WEB ASTM Lbs./LF. (Simple Span)** BEAMS LENGTH HEIGHT CLASS /16 Intermediate-duty /16 Heavy-duty /16 Intermediate-duty / /16 Intermediate-duty /16 Heavy-duty /16 Intermediate-duty /16 Intermediate-duty Cross Tee Load Test Data HANGER SPACING CROSS WEB Lbs./LF. (Simple Span)** TEES LENGTH HEIGHT 4 XL7318/ / XL / XL / XL7328/ / XL8323/ / XL / XL / XL / XL / XL8340/833033/ / XL7340 XL7341/XL / XL / XL7348/ / XL / XL / XL / XL / Seismic Performance MINIMUM LBS. TO PULL OUT MAIN BEAMS COMPRESSION/TENSION 7300, 7302, 7305, , , MINIMUM LBS. TO PULL OUT CROSS TEES COMPRESSION/TENSION All XL cross tees exceed 300 lbs. in both compression and tension. ICC Reports For areas under ICC jurisdiction, see ICC evaluation report number 1308 for allowable values and/or conditions of use concerning the suspension system components listed on this page. The report is subject to reexamination, revisions and possible cancellation. **To derive maximum lbs/sf, divide the on-center spacing of the component into the lbs/lf given in the load test data table. Maximum Fixture Weight LIGHT FIXTURE A. Main Beam to Main Beam Main Beam Hanger Wire ( ) 1. Fixture* 24 x x Planning Module 48 x x Hanger Spacing Item 7300/ lbs lbs Item 7301/ lbs lbs. 1. Fixture* 12 x x Planning Module 48 x x Hanger Spacing Item 7300/ lbs lbs Item 7301/ lbs lbs. 1. Fixture* 24 x x Planning Module 60 x x Hanger Spacing Item 7300/ lbs lbs Item 7301/ lbs lbs. Main Beams tested as follows: 7300 tested at 13.0 lbs./lf to 1/360 of 4 span; 7301 tested at 16.5 lbs./lf to 1/360 of 4 span. LIGHT FIXTURE B. Cross Tee to Cross Tee Main beams Hanger Wire ( ) 1. Fixture* 24 x x Planning Module 48 x x Hanger Spacing Item XL8340/XL lbs lbs. 4. Item XL lbs lbs. 5. Item XL8341/XL lbs lbs. 1. Fixture* 24 x x Planning Module 48 x x Hanger Spacing Item XL8340/XL lbs lbs. 5. Item XL8341/XL lbs lbs. *Fixtures weighing more than 56 lbs. should be independently supported. Fixture weight is based on single fixture only. For end-to-end fixtures or other configurations not shown, consult your Armstrong representative. NOTE: The above data is based on 48 hanger wire spacing, board weight of 1 lb./sf, maximum deflection of tees not to exceed 1/360 of the span, and suspension system installed in accordance with ASTM C636. TechLine SM / ARMSTRONG armstrong.com/ceilings CS All trademarks used herein are the property of AWI Licensing Company and/or its affiliates 2010 AWI Licensing Company Printed in the United States of America

85 GOLD BOND brand GRIDSTONE GYPSUM CEILING PANELS /NGC Technical Information: 800-NATIONAL Description Gold Bond brand Gridstone Gypsum Ceiling Panels consist of a 1/2 in. (12.7 mm) non-combustible, Fire-Shield G Gypsum Core with a 2-mil. white, stipple-textured vinyl laminate face that combines high light reflectance with easy cleanability. Use it in interior and uexposed exterior ceiling applications, such as soffits, parking garages, kitchens and baths. Panels are accepted by the USDA for use in food service and food processing areas. Gridstone Gypsum Ceiling Panels contains no asbestos. Basic Uses APPLICATIONS Use Gridstone Gypsum Ceiling Panels in interior and unexposed exterior ceiling applications, such as soffits, parking garages, kitchen and baths. ADVANTAGES Gridstone Gypsum Ceiling Panels install easily in standard exposed grid systems. A non-combustible gypsum core assures fire safety with 1-1/2- and 2-hour fire rating achievable depending on installation. The sturdy white vinyl laminate eliminates additional finishing. The rigid gypsum core prevents sagging and warping problems and is backed by a 15-year limited warranty. Achieves GREENGUARD and GREENGUARD Gold Certification. GREENGUARD Certified products are certified to GREENGUARD standards for low chemical emissions into indoor air during product usage. For more information, visit: ul.com/gg. Qualifies as a low-voc emitting material by meeting California Specification For more information, visit: calrecycle. ca.gov/greenbuilding/specs/section01350/. If panel cuts are required, seal exposed core with drywall primer to maintain performance of the system. Cleaning: Remove common dirt and stains on the vinyl surface with mild soap or detergent in lukewarm water. Use a light scrubbing action with a cloth, sponge or soft brush. If the suitability of any cleaning agent is unknown, check its effect on the Gridstone Panel surface in a hidden area or on a scrap piece before attempting to remove a field stain. FIRE RATINGS BY TYPE & SIZE (ASTM E119) Type Size Design Rating 1/2 in. (12.7 mm) 2' x 2' UL G222 2 hr. FM FC299 1/2 in. (12.7 mm) FIre-Shield G 2' x 4' UL G259 FM FC /2 hr. DECORATION Gridstone Panels are factory finished decorative products that do not require painting. However, if desired, paint Gridstone with the following products: 1. Oil primer with finish coat of oil or latex paint 2. Two coats of latex paint. Installation Recommendations GENERAL Provide cross ventilation in unheated or enclosed space above ceiling panels Install Gridstone Panels in lay-in suspension systems with edges concealed by flanges of suspension members. Gridstone Panels are designed to be mounted in standard 15/16 in. (24 mm) exposed tee grid systems or environmentaltype grids for severe conditions, with grids either 24 in. (610 mm) x 24 in. (610 mm) or 24 in. (610 mm) x 48 in. (1,219 mm). Grid installation should be conducted according to manufacturer s specification. Vinyl laminate on face of Gridstone Panels is directional. Install with all factory edges parallel (same direction). Each panel must be continuously supported on all four edges. Cut panels to fit tightly at borders and penetrations so that cut edges are concealed by trim pieces and escutcheons. Job Name: Contractor: Date: Submittal Approvals: (Stamps or Signatures) 1

86 TECHNICAL DATA PHYSICAL PROPERTIES Thickness 1, Nominal Width 1, Nominal Gridstone Gypsum Ceiling Panels 1/2" (12.7 mm) 2' (610 mm) Length 1,6,, Standard GB ' (610 mm) actual size is 23-3/4" x 23-3/4" GB ' (1,219 mm) actual size is 23-3/4" x 47-3/4" Weight, Nominal 2.2 lbs./sq. ft. (10.74 k/m 2 ) Edges 1 Finish Face Finish Back Square Predecorated Gypsum Board 1 Class 1 Ceiling Atenuation Class (CAC) 4,5 Light Reflectance 5 Product Standard Compliance 2 mil. White Stipple Vinyl Laminate N/A 46 db LR 1 (75% or greater) ASTM C1396 Fire-Resistance Characteristics Core Type Type X UL Type Designation FSW-G Combustibility 2 Non-combustible Core Surface Burning Characteristics 3 Class A Flame Spread 3 5 Smoke Development 3 0 Applicable Standards and References ASTM C473 Standard Test Methods for Physical Testing of Gypsum Panel Products ASTM C840 Standard Specification for Application and Finishing of Gypsum Board ASTM C1396 Standard Specification for Gypsum Board ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials ASTM E136 Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 C ASTM E1264 Standard Classification for Acoustical Ceiling Board ASTM E1414 Standard Test Method for Airborne Sound Attenuation Between Rooms Sharing a Common Ceiling Plenum Gypsum Association, GA-216, Application and Finishing of Gypsum Panel Products National Gypsum Company, NGC Construction Guide 1. Specified values per ASTM C1396, tested in accordance with ASTM C Tested in accordance with ASTM E Tested in accordance with ASTM E Tested in accordance with ASTM E Tested in accordance with ASTM C1264, Type XX, Patterns E and G. 6. Please consult your local sales representative for all non-standard lengths and widths. Minimum order requirements may apply. 2

87 GOLD BOND brand GRIDSTONE GYPSUM CEILING PANELS Limitations /NGC For More Information Technical Information: 800-NATIONAL Do not install panels in areas exposed to extreme or continuous moisture, such as saunas, steam rooms, gang showers and indoor pool enclosures. Do not exceed 104 F (40 C) or 90 percent relative humidity prior to, during and after installation. For exterior application, protect grid panels from direct exposure to weather, water and continuous high humidity. Limit supported insulation to 1.6 psf (4.88 k/m 2 ). Overlaid insulation may cause excessive panel deflection and is not recommended where high humidity is likely to occur. Extreme lighting conditions may distort texture appearance. Do not use strong organic solvents (such as ketones), harsh abrasive cleaners or steel wool. These materials may cause dulling, discoloration, softening and other permanent damage to the vinyl surface. ARCHITECTURAL SPECIFICATIONS National Gypsum Company s CSI Master Format 3-part guide specifications are downloadable as editable Microsoft Word documents at: nationalgypsum.com. LATEST INFORMATION AND UPDATES For the latest technical information and updates, call NGC Construction Services: NATIONAL ( ) or visit our website: nationalgypsum.com. HANDLING AND PROJECT CONDITIONS Avoid water exposure during shipping, handling, storage and installation, and after installation of gypsum ceiling panels in order to avoid the formation of mold or mildew. Remove nonbreathable shipping wrap material upon receiving and storing gypsum panels. Store gypsum ceiling panels off the ground and under cover. Use sufficient supports extending under the entire length of gypsum board to prevent sagging. Keep gypsum ceiling panels dry to minimize the potential for mold growth. Take adequate care while transporting, storing, applying and maintaining gypsum ceiling panels. For additional information, refer to GA-238, which is available at gypsum. org under the Download Gypsum Association Publications section. Protect gypsum ceiling panels from the elements and maintain in good condition prior to and following installation. Stack panels flat, with care taken to prevent sagging or damage to edges, ends or surfaces. Do not install gypsum ceiling panels with visible signs of mold growth. Do not apply gypsum ceiling panels over other building materials where conditions exist that are favorable to mold growth. Do not exceed 95 F (35 C) when using a temporary heat source. Refer to GA-801 for complete handling and storage instructions. 3

88 2001 Rexford Road Charlotte, NC (704) NationalGypsum.com AskForPurple.com Rev. 08/16 4

89 Clean & Durable surface systems GLASBORD Wall Panels with Surfaseal Finish It s a dirty world out there. Protect your facility with Crane Composites resilient wall coverings. Our Glasbord with Surfaseal creates surfaces that deliver unsurpassed hygiene and durability for commercial environments such as restaurants and food processing plants. GLASBORD EMBOSSED STONE (15) Made of fiberglass reinforced plastic (FRP), Glasbord with Surfaseal is extremely moisture-resistant and non-porous. The Surfaseal film finish, found only on Glasbord, provides a barrier that s highly resistant to impact and scratching. Because of it s unique process, the Surfaseal finish will not trap soil or bacteria on the panel. The surface is up to 10 times easier to clean and up to six times more stain resistant than other sanitary wall systems. The sturdy panels, which come in both pebbled and smooth textures, hold up under frequent maintenance cycles, and proven performance at an affordable price point with a 10-year limited warranty. embossed & smooth textures

90 GLASBORD with Surfaseal PEBBLED EMBOSSED TEXTURE White 85 Colonial White 83 Ivory 84 Soft Beige 70 Stone 15 Silver 66 Pearl Gray 48 Black 1201 * SMOOTH TEXTURE White 85 PRODUCT SPECS Gray 636 * AVAILABLE SIZES 4' x 8' 4' x 10' THICKNESS 0.09" (embossed) 0.075" (smooth) FIRE RATINGS Class A or Class C per ASTM-E84 CAN/ULC-S102 FM Approval Available ADDITIONAL PRODUCT OFFERINGS Ceiling and laminated panels also available. See our ceiling application flyer (form 7714) for additional information. Ivory 84 * Patterns and colors are a representation and may not accurately reflect the final product. Please obtain a sample of the product before making a final selection at FRPSamples.com * Embossed Black, Smooth Gray and Ivory are available in a Class C fire rating only ACCESSORIES Standard Vinyl/PVC Moldings Polyurethane Seam Sealant MANUFACTURING FOR OVER 60 YEARS! A global leading provider of resilient wall and ceiling coverings. Kemlite was established in 1954 and the company changed names to Crane Composites in Crane Composites is headquartered in Channahon, IL and all our products are manufactured in the United States. We work with hundreds of distributors, ensuring our products are easily accessible and readily available to our customers. USDA/FSIS CERTIFIED Glasbord panels meet USDA/FSIS requirements for a finished outer surface material that is rigid, durable, non-toxic, non-corrosive and moisture resistant. FACTORY MUTUAL APPROVAL Glasbord (FXE and FSFM) is the only interior FRP panel that is accepted under Factory Mutual Research approved Plastic Interior Finish Materials when installed in accordance with Factory Mutual Research Approval Standard This information is available at cranecomposites.com/fmapproved.pdf. cranecomposites.com [fax] sales@cranecomposites.com The following are trademarks of Crane Composites, Inc. or a related company: Glasbord, Kemlite, Kemply, Surfaseal, Sanigrid, Silhouette Trims and Varietex 6312 REV (7894)

91 CLEANING INSTRUCTIONS For FRP Panels and Ceiling Grid Systems FORM 2543 FREQUENCY Clean weekly or on a regular schedule so soil and dirt will not build up. A mild cleaner will do nicely. MATERIAL A 5% to 10% trisodium phosphate water solution not to exceed 130 F can be used. If trisodium phosphate is not available in your area, use a 5% to 10% solution of household automatic dishwasher detergent. If a USDA/FSIS or FDA approved cleaner is required, neutral cleaner (PH range ) is preferred. Follow the manufacturer s directions. Do not use a cleaner or stain remover that contains chlorinated hydrocarbons or aromatic hydrocarbons. Do not use abrasive cleaners. METHOD The embossed surface of FRP panels can best be cleaned with a sponge or soft brush. Apply the cleaner, working it across the surface in a scrubbing or circular motion. Rinse very thoroughly to remove all traces of the trisodium phosphate, otherwise a film will build up giving the wall a dull, dirty appearance. When using a specialty cleaner, follow the manufacturer s instructions. Test a small area before applying over the entire surface. Removing Normal Grime or Dirt Steam-cleaning procedures normally employed on ceramic wall surfaces in USDA/FSIS inspected facilities may be use on FRP wall and ceiling panels. A 10% solution of trisodium phosphate in warm water (not to exceed 130 F), may be applied in a scrubbing motion, using sponge, brush, or cloth. Rinse thoroughly after cleaning. Removing Hard Water Deposits A 10% solution of acetic acid in cold water may be applied in a scrubbing motion, using sponge, brush, or cloth. Rinse thoroughly after cleaning. Removing Oil Residues or Difficult Substances Mineral spirits, applied with a clean cloth, will aid in removing most oily residues or substances. cranecomposites.com [fax] sales@cranecomposites.com We believe all information given is accurate. It is offered in good faith, but without guarantee. Since conditions of use are beyond our control, all risks are assumed by the user. Nothing herein shall be construed as a recommendation for uses which infringe on valid patents or as extending a license under valid patents. See our most current SDS at cranecomposites.com/sds.html prior to working with our products. A global leading provider of resilient wall and ceiling coverings. Kemlite was established in 1954 and the company changed names to Crane Composites in Crane Composites is headquartered in Channahon, IL and all our products are manufactured in the United States. We work with hundreds of distributors, ensuring our products are easily accessible and readily available to our customers. The following are trademarks of Crane Composites, Inc. or a related company: Glasbord, Kemlite, Kemply, Surfaseal, Sanigrid, Silhouette Trims and Varietex 2543 REV (8064)

92 From: Sent: To: Subject: Donald Trauthwein Friday, December 15, :13 PM ACF VERNE; Matthew Reimer Estreet winner flooring Donny Trauthwein

93 MAINTENANCE MAINTENANCE RECOMMENDATIONS CERAMIC CARPET SYSTEMS Floor systems generally take the most abuse of any surface in a building and therefore, require regular maintenance. Daily Maintenance Dust mop with clean non-oily dust mop of size to suit floor area. Remove fine dust particles frequently from mop with a vacuum hose. Remove any wet spillage by damp mopping. NOTE: Aggressive skid-inhibiting surfaces such as those found in locker rooms, showers, decks, pool areas, ramps, food areas, and like surfaces require brush scrubbing followed by water rinse, normal cleaning with a mop will not properly clean the textured surface. Periodic Maintenance Damp mop the surface Scrubbing is required with a skid-inhibiting surface or when a smooth surface becomes very soiled. Use a bristled brush or a bristle attachment on a power scrubber (not a nylon pad) using a detergent solution to dislodge the dirt. The type of detergent will depend on the degree and type of build-up on the floor surface. Use an All-Purpose cleaner for areas exposed to light traffic dirt. Extremely heavy-duty soils, oil, grease, and rubber marks, etc., may be removed using a cleaner / degreaser. After scrubbing, the floor should be rinsed and vacuumed to prevent the dirt from re-settling on the floor. Caution: Some cleaners will affect the color, gloss or texture of your polymer floor surfaces. To determine how your cleaner will perform, we recommend that you first test each cleaner in a small area, utilizing your cleaning technique. This precaution will demonstrate the effect of your cleaner and technique. If no deleterious effects are observed, continue with the procedure. If deleterious effects do occur, modify the cleaning material and/or procedure. INITIAL CLEANING Due to the amount of construction debris, vigorous cleaning may be necessary. Use a soft blue brush on a buffer using mild detergents. Vigorous cleaning may cause some loss of gloss. See Periodic Maintenance. Loss of gloss does not affect performance of the system. To learn more,visit us at or call to have a representative contact you The Sherwin-Williams Company Protective & Marine Coatings 01/12 GPM Ceramic Carpet/12 Page 1 of 1

94 SUBMITTAL COVER SHEET Monday, November 13, 2017 PROJECT: European Street San Marco MATERIALS UNDER SUBMITTAL: Toilet Accessories SUBMITTED TO: Intracoastal Builders Corporation SUBMITTED BY: Ana Blanchette

95 SUBMITTAL REVIEW NOTES: Corrections or comments made on this submittal during this review DOES NOT relieve the Contractor, Construction Manager or Architect from compliance with requirements of the drawings and specifications. This submittal reflects Specialty Distributors of Florida, LLC s interpretation of design concept of the project and general compliance with the Plans and Specifications provided by Contractor and/or Architect. REQUIRED REVIEW CONFIRMATIONS: Color Selection: _ Firm Field Measurements Required Verify Rough Openings Verify Blocking in Walls/Ceilings _X_ Delivery Date for Material: ADDITIONAL NOTES: The Contractor and/or Architect is responsible for confirming and correlation all quantities, openings, color selection, field measurements, blocking, ADA CODE & REQUIREMENTS, and date that materials should be on site for installation. ARCHITECT STAMP/REVIEW CONTRACTOR STAMP/REVIEW

96 AJW Architectural Products U126 Soap Dispenser Revision 11/14 JOB #: ITEM #: QUANTITY: MOUNTING HANDING TYPE SIZE OTHER 4 3/4 121 mm Wall Plate 2 7/8 73 mm s s s Refill Indicator s 8 1/4 210 mm s 7/8 21mm SPECIFICATIONS Soap Tank: welded one-piece construction. Valve: All purpose antibacterial soap valve cylinder, black molded plastic push style valve that takes less than 5 lbs of force and one hand to operate complies with barrier free guidelines when mounted at proper height. Viewer: Concealed Mounting Plate: Fabricated of heavy gauge stainless steel. Filler Cap: Fabricated of stainless steel, hinged to allow easy servicing, secured with special key that creates a vandal resistant dispenser. Overall Size: 4 3/4 W x 8 1/4 H x 3 3/4"D (wall to valve) 121mm x 210mm x 95mm Capacity: 40 oz. Recommend type soaps without chloric solutions for proper operation. INSTALLATION Secure concealed mounting plate to wall surface with proper fasteners. Slide dispenser down over mounting plate and secure by means of set screw located inside tank. Fill unit with proper soap. Close lid and secure with special key. Test valve for proper operation. *It is not recommended to mount any soap dispenser on mirrors **For best performance, use pre-mixed low concentrate solutions. Dispensers should have periodic maintenance performed to insure the life dispenser. Rinse out globe and valve with warm water to avoid sludge buildup. Every 30 days with warm water to prevent valve from clogging with old soap. Do not use abrasive cleaners to clean dispenser. NOTES. This information is subject to change without formal notice. If you need additional help, AJW has a technical support staff that is ready to assist you by phone: (845) , fax: (845) , engineering@ajw.com or visit our website: Copyright 2013 AJW Architectural Products

97 AJW Architectural Products U591 Surface Mounted Sanitary Napkin Disposal Revision 1/14 JOB #: ITEM #: QUANTITY: MOUNTING HANDING TYPE SIZE OTHER mm 1/4 6 mm s s mm s 10 1/8 257 mm s s 30 (762mm) Recommended Mounting Height SPECIFICATIONS Cabinet Body: Fabricated of #22 ga stainless steel with #4 satin finish. Seamless construction with radius and hemmed edges. Cabinet Back: Stainless steel welded to cabinet body with key hole mounting points. Cover: Fabricated of #22 ga stainless steel #4 satin finish with embossed handles on each side and sloped top. Hinge: Heavy duty, full length, stainless steel piano type hinge. Overall Size: 9 W x 10 1/8 H x 4 D 229mm x 257mm x 102mm Capacity: 1.6 gallons (.2 cu ft) NDL-13-50: Waxed disposable liners. (50 per Case) INSTALLATION Provide an area at desired or specifi ed location. Place unit on surface and transfer mounting points. Drill pilot holes and secure with proper fasteners. Install waxed liner. NOTES. This information is subject to change without formal notice. If you need additional help, AJW has a technical support staff that is ready to assist you by phone: (845) , fax: (845) , engineering@ajw.com or visit our website: Copyright 2013 AJW Architectural Products

98 AJW Architectural Products TM U711 Series Channel Frame Mirror Revision 11/15 JOB #: ITEM #: QUANTITY: MOUNTING HANDING TYPE SIZE OTHER W 1/2 13 mm 1 5/8 41 mm 1 5/8 41 mm CHANNEL FRAME PADDING MOUNTING SURFACE 3 1/4 83 mm MIRROR BACK H MIRROR SURFACE BACK ASSEMBLY 3 1/4 83 mm LOCK TAB Embossed Brackets MOUNTING BRACKET SPECIFICATIONS Frame: Fabricated of #20 ga stainless steel, #4 satin finish. Roll formed 1/2 x 1/2 x 1/2 channel frame has mitered corners and secured with stainless steel rivet. Mirror: 1/4 thick type 1 transparent flat type, class 1 - clear glass mirrors. Mirror is coated with silver and sealed with a uniform electrolytic copper plating, along with two coats of paint for added protection. Mirrors are guaranteed against silver spoilage for a period of 15 years. Mirrors conform to ASTM C1036 and ASTM C1503-R8. Filler: Full size, 1/8 shock absorbing, water resistant, nonabrasive, polyethylene padding protects all concealed mirror surfaces. Back: #20 ga pre-plated galvanized steel, with embossed horizontal louver mounting brackets. Embossed theft resistant pressure activated clip lock device, locks mirror in place to wall hangers. Hangers: Fabricated of #20 ga pre-plated steel galvanized steel with mounting points. Standard Sizes Available (W x H): 16"x20", 16 x24, 16 x30, 18 x24, 18 x30, 18 x36, 24 x30, 24 x36, 24 x42, 24 x48, 18"x60", 20"x60", 24 x60, 18 x72, 24 x72 INSTALLATION Coordinate installation with architect / contractor for specific mounting location and height for each mirror application. Making sure I bracket is level, transfer all mounting point locations to wall surface from drawing. Secure brackets with proper fasteners for each application. Slide mirror down over horizontal brackets until clip lock secures mirror in place. Mirror can only be removed by inserting tool through hole at bottom of frame depressing clip. This will allow mirror to slide up over brackets. Fillers are available if mirrors are mounted above and below tile line. (U004 Filler) filler material will match mirror frame to form a one piece construction. To meet ADA Code, bottom edge of reflective surface can be no higher than 40 above finished floor. (4.19.6) Full length mirrors may be used for universal application when installed in correct locations. Abrasive cleaners & chloric solutions should not be used on mirrors. Discoloring and /or scratching of frame and reflective surface may occur. Options: LG: Laminated Glass LX: Polycarbonate PM: Plastic Acrylic T: Tempered Glass VC: Vinyl Clad (Safety Glass) 8B: #8 Reflective Stainless Steel *Stainless steel mirrors reflect images in different optic quality than plate glass. There will be a slight distortion which increases proportionately with the mirror size. Therefore, AJW Architectural Products cannot be held responsible for quality of image. NOTES **Mirrors are always ordered Width x Height ***Recommended max size for 8B mirrors: 72 x 47-1/2 ****Framed mirrors are fabricated to a tolerance of (+/-) 1/8 ***** Mirrors conform to Federal Specifications DD-M-00411b & DD-g-541D This information is subject to change without formal notice. If you need additional help, AJW has a technical support staff that is ready to assist you by phone: (845) , fax: (845) , engineering@ajw.com or visit our website: Copyright 2013 AJW Architectural Products

99 AJW Architectural Products UG3-A Grab Bars Revised 03/11 JOB #: ITEM #: QUANTITY: MOUNTING HANDING TYPE SIZE OTHER C L Length 1 C L SPECIFICATIONS & INSTALLATION Tubing: Fabricated of #18 ga stainless steel with a #4 satin finish. Available in 1 1/2 outside diameter. All bends are formed by an automatic mandrel bending process. All bars maintain a constant 1 1/2 offset. Finish: Standard finish is a #4 satin finish. For a non-slip finish (peened) add suffix X to model number. (Ex. UG3X-A) Flanges: Snap flanges are fabricated of 3 diameter, 3/8 deep drawn #22 ga stainless steel with #4 satin finish to match tubing. Flanges have dimples that secure over mounting plate. Strength: Bars with a 1 1/2 offset clearance will support loads in excess of 900lbs when properly installed. Bars with greater offsets will support loads up to 250lbs when properly installed. Installation: Before installing grab bars, verify with all state and local codes for requirements on bar diameter and type finish. Recommended mounting heights for grab bars are centerline above finished floor. All mounting of grab bars when possible should have in wall mounting back plates. Find centerline mounting points and place bar on line making sure to be on center. Transfer mounting points (3 per flange) to wall. Drill pilot holes and secure bar with proper anchors per application. Snap cover over mounting plate. Standard Lengths (Other sizes available upon request): 12, 16, 18, 24, 30, 32, 36, 42, 48, 50, 52, 54, 56 FLANGE INFORMATION 1 1/4 or 1 1/2 (32mm, or 38mm) 1 1/2 (38mm) Offset 3 (76mm) 13/32 O.D. 1/4 O.D. 18 GA 22 GA 90 o BEND 14 GA. 3 O.D. To Accomodate 1 1/4-1 1/2 Intermediate Support Flange NOTES 3 (76mm) 9/32 O.D. 14 ga. 3 O.D. To Accomodate 1 1/4-1 1/2 This information is subject to change without formal notice. If you need additional help, AJW has a technical support staff that is ready to assist you by phone: (845) , fax: (845) , engineering@ajw.com or visit our website: Copyright 2013 AJW Architectural Products

100 AJW Architectural Products UG3-A Grab Bars Revised 03/11 JOB #: ITEM #: QUANTITY: MOUNTING HANDING TYPE SIZE OTHER C L Length 1 C L SPECIFICATIONS & INSTALLATION Tubing: Fabricated of #18 ga stainless steel with a #4 satin finish. Available in 1 1/2 outside diameter. All bends are formed by an automatic mandrel bending process. All bars maintain a constant 1 1/2 offset. Finish: Standard finish is a #4 satin finish. For a non-slip finish (peened) add suffix X to model number. (Ex. UG3X-A) Flanges: Snap flanges are fabricated of 3 diameter, 3/8 deep drawn #22 ga stainless steel with #4 satin finish to match tubing. Flanges have dimples that secure over mounting plate. Strength: Bars with a 1 1/2 offset clearance will support loads in excess of 900lbs when properly installed. Bars with greater offsets will support loads up to 250lbs when properly installed. Installation: Before installing grab bars, verify with all state and local codes for requirements on bar diameter and type finish. Recommended mounting heights for grab bars are centerline above finished floor. All mounting of grab bars when possible should have in wall mounting back plates. Find centerline mounting points and place bar on line making sure to be on center. Transfer mounting points (3 per flange) to wall. Drill pilot holes and secure bar with proper anchors per application. Snap cover over mounting plate. Standard Lengths (Other sizes available upon request): 12, 16, 18, 24, 30, 32, 36, 42, 48, 50, 52, 54, 56 FLANGE INFORMATION 1 1/4 or 1 1/2 (32mm, or 38mm) 1 1/2 (38mm) Offset 3 (76mm) 13/32 O.D. 1/4 O.D. 18 GA 22 GA 90 o BEND 14 GA. 3 O.D. To Accomodate 1 1/4-1 1/2 Intermediate Support Flange NOTES 3 (76mm) 9/32 O.D. 14 ga. 3 O.D. To Accomodate 1 1/4-1 1/2 This information is subject to change without formal notice. If you need additional help, AJW has a technical support staff that is ready to assist you by phone: (845) , fax: (845) , engineering@ajw.com or visit our website: Copyright 2013 AJW Architectural Products

101 AJW Architectural Products U944 Baby Changing Station Revision 11/14 JOB #: ITEM #: QUANTITY: MOUNTING HANDING TYPE SIZE OTHER (500 mm) SPECIFICATIONS Body: FDA approved injection molded polypropylene with Microban antimicrobial additive. Reinforced steel-on-steel hinge mechanism and in four languages. Liner Dispenser: An integral part of body that is standard with each unit. (Capacity: 50) Pneumatic Cylinder: Concealed penumatic cylinder & hinge structure provides controlled and smooth open and close motion. Safety Straps: Nylon safety strap snap lock fastens to hold child securely in place. Overall Size: 35 3/16 W x 22 1/4 H x 4 D (closed) 23 3/16 D (open) 894mm x 565mm x 102mm (closed), 589mm (open) Available Colors: Cream & Grey Optional Braille Label (Not included) INSTALLATION Coordinate installation with architect or contractor to avoid interference with surrounding objects. Hold unit up to wall and open to verify there are no obstructions to interfere with operation of station. From Transfer mounting point locations to wall surface and drill pilot holes. Secure unit with proper fasteners for each application. (Recommend and into position with less than 5 lbs of force, wall openingut turning or twisting of wrist. Verify with local codes and type approach (forward or up to 200lbs when properly installed. Unit should be cleaned once or more daily with a clean nylon brush and spray disinfectant. When properly installed, baby changing stations comply with ASTM static load performance requirements. NOTES Formerly Model #: U945H This information is subject to change without formal notice. If you need additional help, AJW has a technical support staff that is ready to assist you by phone: (845) , fax: (845) , engineering@ajw.com or visit our website: Copyright 2013 AJW Architectural Products

102 SUBMITTAL COVER SHEET Monday, November 13, 2017 PROJECT: European Street San Marco MATERIALS UNDER SUBMITTAL: Fire Protection Specialties SUBMITTED TO: Intracoastal Builders Corporation SUBMITTED BY: Ana Blanchette

103 SUBMITTAL REVIEW NOTES: Corrections or comments made on this submittal during this review DOES NOT relieve the Contractor, Construction Manager or Architect from compliance with requirements of the drawings and specifications. This submittal reflects Specialty Distributors of Florida, LLC s interpretation of design concept of the project and general compliance with the Plans and Specifications provided by Contractor and/or Architect. REQUIRED REVIEW CONFIRMATIONS: Color Selection: _ Firm Field Measurements Required Verify Rough Openings Verify Blocking in Walls/Ceilings _X_ Delivery Date for Material: ADDITIONAL NOTES: The Contractor and/or Architect is responsible for confirming and correlation all quantities, openings, color selection, field measurements, blocking, ADA CODE & REQUIREMENTS, and date that materials should be on site for installation. ARCHITECT STAMP/REVIEW CONTRACTOR STAMP/REVIEW

104 PROJECT: MODEL NUMBER: ARCHITECT: DATE: Fire Extinguishers MP,DC & HT Series Submittal and Detail Sheet MP SERIES-Multi-Purpose Dry Chemical These units contain specially fluidized and siliconized mono ammonium phosphate powder which smothers and breaks the chain reaction on Class B fires, fuses and insulates Class A fires, and, as a non-conductor of electricity, is effective on Class C fires. DC SERIES-Regular Dry Chemical These units contain specially siliconized sodium bicarbonate powder with free flowing and non-caking additives, suitable for fires in flammable liquids, and energized electrical equipment. All multi-purpose and regular dry chemical units feature: Heavy DOT steel cylinders * Rugged metal valves and siphon tubes * Replaceable molded valve stem seals * Pull pinupright squeeze grip operation * Approved to -65 degrees F. * Non-toxic * Pressure gauges* HT SERIES-Halotron I Halotron I is an EPA approved clean agent which discharges as a rapidly evaporating liquid, leaving no residue. It effectively extinguishes Class A, B and C fires and is intended for use in areas formerly protected by Halon LOCATION: QUANTITY: CONTRACTOR: DISTRIBUTOR: MODEL NUMBER NOMINAL CAPACITY SHIPPING WEIGHT CYLINDER DIAMETER OVERALL HEIGHT OVERALL WIDTH UL RATING STANDARD BRACKET* OPTIONAL BRACKET** MP2½ MP5 MP5-A MP6 MP10 MP20 DC2½ DC5 DC6 DC10 DC20 2½ lbs. 5 lbs. 5 lbs. 6 lbs. 10 lbs. 20 lbs. 2½ lbs. 5½ lbs. 6 lbs. 10 lbs. 20 lbs. 5½ lbs. 9¼ lbs. 9¼ lbs. 12¾ lbs. 18 lbs. 38 lbs. 5½ lbs. 9½ lbs. 13 lbs. 18 lbs. 38 lbs. 3 in. 4¼ in. 4¼ in. 5 in. 5 in. 7 in. 3 in. 4¼ in. 5 in. 5 in. 7 in. 15½ in. 15¼ in. 15¼ in. 16 in. 20in. 23¼ in. 15½ in. 15¼ in. 16¼ in. 20 in. 23¼ in. 5¾ in. 7¼ in. 7¼ in. 7¾ in. 7¾ in. 10¼ in. 5-3/4 in. 7¼ in. 8½ in. 7-3/4 in. 10¼ in. 1A-10B:C 2A-10B:C 3A40B:C 3A-40B:C 4A-80B:C 1OA-12OB:C IOB:C 4OB:C 4OB:C 6OB:C 12OB:C B 2, 818, 821, , 821, , 862 B-2, 846, B-2, 818, 821, , 862 B-2, 846, HT2½ HT5 HT11 HT15½ 2½ lbs. 5 lbs. 11 lbs. 15½ lbs. 5¼ lbs. 9½ lbs. 22½ lbs. 27½ lbs. 3 in. 4¼ in. 6 in. 6 in. 15½ in. 15¼ in. 21 in. 21 in. 5½ in. 5-3/4 in. 9¼ in. 9¼ in. 2B:C 5B:C 1A:10B:C 2A:10B:C N/A N/A *NOTE: Standard brackets are included with all extinguishers at no additional cost. If specified, optional brackets are only available at additional cost. All of the above brackets are designed to accommodate Larsen's extinguishers. While most comparably sized extinguishers usually will function with the above brackets, Larsen's cannot assume responsibility for variations in cylinder dimensions among various extinguisher suppliers. LARSEN'S MANUFACTURING COMPANY 7421 Commerce Lane N.E., Mpls, MN Phone: (763) FAX: (763) FLORIDA DIVISION: 3130 N.W. 17 th Street, Ft. Lauderdale, FL Phone: (954) FAX: (954) Larsen's Mfg. Co.

105 PROJECT: MODEL NUMBER: ARCHITECT: DATE: Fire Extinguishers- PW, WC, WM & CD Series Submittal and Detail Sheet PW SERIES-Pressurized Water This unit is ideally suited for all industrial and commercial applications, where easy to use, positive on-off operation is important. Water is used as the extinguishing agent, making it highly effective on deep seated Class A fires. (Shipped empty.) WC SERIES-Wet Chemical Wet Chemical units are designed specifically for kitchen grease fire hazards and meet the new K class listing now required for all extinguishers installed in restaurant kitchens. They contain a special potassium acetate based, low PH agent, which leaves no chemical residue to clean up. The spray applicator wand keeps the operator at a safe distance from the fire. Larger 2-1/2 gallon unit with identical U.L. rating is available. (shipped charged) WM SERIES-Water Mist This unit is designated for use wherever there is a Class A hazard near electrical equipment and the environment is of paramount concern. The extinguishing agent is de-ionized water, and the wand provides greatest operator safety. There is no risk of electrical conductivity or thermal or static shock. Ideal for use in health care, data processing, telecommunication, and clean room facilities. (Shipped empty) LOCATION: QUANTITY: CONTRACTOR: DISTRIBUTOR: MODEL NUMBER PW2½ WC 6L WC2½ WM2½ NOMINAL CAPACITY 2½ gal. 6 liters 2½ gal. 2½ gal. SHIPPING WEIGHT 7½ lbs. 23 lbs. 34 lbs. 9 lbs. CYLINDER DIAMETER 7 in. 7 in 7 in. 7 in. OVERALL HEIGHT 24½ in. 19 in. 24½ in. 26 in. OVERALL WIDTH 9 in. 9 in. 9 in. 11 in. UL RATING 2A 2A:K 2A:K 2A:C CD SERIES---Carbon Dioxide These units contain liquid carbon dioxide under pressure. It is discharged as a white cloud of "snow," which effectively smothers a fire. Carbon dioxide is a clean, non-conductor of electricity for Class B and C fires. MODEL NUMBER CD5 CD10 CD15 CD20 NORMAL CAPACITY 5 lbs. 10 lbs. 15 lbs. 20 lbs. SHIPPING WEIGHT 14 lbs. 28¼ lbs. 37¾ lbs. 50¾ lbs. All carbon dioxide units feature: CYLINDER DIAMETER 5¼in. 7 in. 7 in. 8 in. OVERALL HEIGHT 17¾ in. 24 in. 30 in. 30 in. OVERALL WIDTH 8¼ in. 12 in. 12 in. 13 in. UL RATING 5-B:C 10:B:C 10:B:C 10:B:C STANDARD BRACKET* OPTIONAL BRACKET* 862 N/A STANDARD BRACKET* OPTIONAL BRACKET* B1, 864 B ring seal, straight thread brass valve-fits all size Absolutely rust free aluminum cylinders Up to 30% lighter *NOTE: Standard brackets are included with all extinguishers at no additional cost. If specified, optional brackets are only available at additional cost. All of the above brackets are designed to accommodate Larsen's extinguishers. While most comparably sized extinguishers usually will function with the above brackets, Larsen's cannot assume responsibility for variations in cylinder dimensions among various extinguisher suppliers. LARSEN'S MANUFACTURING COMPANY 7421 Commerce Lane N.E., Mpls, MN Phone: (763) FAX: (763) FLORIDA DIVISION: 3130 N.W. 17 th Street, Ft. Lauderdale, FL Phone: (954) FAX: (954) Larsen's Mfg. Co.

106 Plumbing Submittal EUROPEAN STREET O & M MANUAL Submitted by AMERICAN PLUMBING 2/9/2018 HAJOCA 6964 HIGHWAY AVE - UNIT 2 JACKSONVILLE, FL Phone: Fax:

107 Spec# Table of Contents 1... WATER CLOSET VORTENS 3151 WHT MEDALIST EL BOWL(O&M only) VORTENS 3123 WHT EL ADA VIENNA PLUS BOWL(O&M only) VORTENS 3494 WHT 1.6GPF MEDALIST TANK(O&M only) B 1955CT WHT EL OF LC PLAS SEAT W/ STA-TITE CK HINGE(O&M only) 6... WALL HUNG LAVATORY KOHLER K WHT VC KINGSTN 211/4X181/8X121/4 3H WM 4CC LAV BASIN(O&M only) MAINLINE ML102EZ WHT LAV-GUARD TRAP & SUPPLY COVER F/ TUBULAR P-TRAP 2-ANGLE STOP & 2- SUPPLY ADA APPROVED(O&M only) MAINLINE 211E-CP POL CHROME CENTURION 1.2 GPM 2H DM 4CC SGL METAL LEVER HDL LAV FCT ADA APPROVED LEAD FREE(O&M only) URINAL KOHLER K-5016-ET-0 WHT DEXTER WM 0.5GPF 3/4 TOP SPUD URINAL(O&M only) S XL 1.0 REGAL URINAL FLUSH VLV(O&M only) RECIRCULATION PUMP B UP1529SF 115V CIRC PUMP(O&M only) B /4 CLIP ON AQUASTAT(O&M only) THERMOSTATIC MIXING VALVE LV 170-LF 3/8 OTLT & COMP INLT TEMP LIMITING VLV LEAD FREE(O&M only)

108 WATER CLOSET Spec Seq#: 1

109 Spec Seq#:

110 PARTS BREAKDOWN ITEM QTY PARTS BREAKDOWN ITEM QTY PARTS BREAKDOWN ITEM QTY Spec Seq#: 3 HIGH-EFFICIENCY TOILETS 1.6 GPF / 6.0 LPF TOILETS SUITES TANK 3473 TANK 3469 TANK 3451 TANK GPF HURRICANE ADA / HURRICANE EL / HURRICANE FORZA ADA / FORZA EL / FORZA RF REGENCY EL PRESSURE ASSIST RF TORNADO / TORNADO ADA FILL VALVE V PARTS BREAKDOWN ITEM QTY PILOT VALVE V333-3V 1 PILOT VALVE V121 1 FLUSH VALVE V COMPLEMENT BAG V FLUSH VALVE V FLUSH VALVE V203 1 COMPLEMENT BAG V METALIC BOLTS V210 2 COMPLEMENT BAG V COMPLEMENT BAG V FLUSH HANDLE AND ARM V253 1 SLOAN 1.0 GPF TANK V FLUSH HANDLE AND ARM V227 1 FLUSH HANDLE AND ARM V171 1 METALIC BOLTS V BOLT CAP V METALIC BOLTS V METALIC BOLTS V136 2 BOLT CAP V TANK TO BOWL GASKET V245 1 BOLT CAP V BOLT CAP V TANK LID TANK LID TANK TO BOWL GASKET V245 1 TANK 3475 TANK 3450 LORETTO ADA / LORETTO EL / LORETTO RF TANK 3126 TANK GPF REGENCY RF PALERMO PRESSURE ASSIST PARTS BREAKDOWN ITEM QTY TORNADO / TORNADO ADA FILL VALVE V333-2V 1 PARTS BREAKDOWN ITEM QTY PARTS BREAKDOWN ITEM QTY FLUSH VALVE V PARTS BREAKDOWN ITEM QTY PILOT VALVE V257 1 PILOT VALVE V333-V 1 COMPLEMENT BAG V COMPLEMENT BAG V FLUSH VALVE V252 1 FLUSH VALVE V FLUSH HANDLE AND ARM V227 1 METALIC BOLTS V210 2 FLUSH HANDLE AND ARM V189 1 COMPLEMENT BAG V METALIC BOLTS V SLOAN 1.0 GPF TANK V251 1 SEAT FLUSH HANDLE AND ARM V189 1 BOLT CAP V BOLT CAP V METALIC BOLTS V TANK TO BOWL GASKET V TANK 3464 BOLT CAP V VIENNA RF / VIENNA ELX / RHODAS ADA TANK LID TANK TO BOWL GASKET V245 1 TANK 3436 RHODAS ADA DF / VIENNA EL DF / VIENNA RF DF PARTS BREAKDOWN ITEM QTY TANK 3450-L TANK GPF REGENCY RF PARTS BREAKDOWN ITEM QTY PILOT VALVE V183-R 1 PRESSURE ASSIST TORNADO / TORNADO ADA FILL VALVE V121-V 1 FLUSH VALVE V293 1 FLUSH VALVE V221 1 COMPLEMENT BAG V PARTS BREAKDOWN ITEM QTY COMPLEMENT BAG V PARTS BREAKDOWN ITEM QTY FLUSH HANDLE AND ARM V191-S 1 PILOT VALVE V121 1 TANK TO BOWL GASKET V245 1 COMPLEMENT BAG V METALIC BOLTS V FLUSH VALVE V203 1 METALIC BOLTS V METALIC BOLTS V210 2 BOLT CAP V COMPLEMENT BAG V BOLT CAP V SLOAN 1.28 GPF TANK V276 1 TANK TO BOWL GASKET V245 1 FLUSH HANDLE AND ARM V BOLT CAP V TANK LID METALIC BOLTS V136 2 TANK TO BOWL GASKET V BOLT CAP V TANK 3437 TANK LID TANK TO BOWL GASKET V245 1 TANK 3465 RHODAS ADA DF / VIENNA EL DF / VIENNA RF DF VIENNA RF / VIENNA ELX / RHODAS ADA PARTS BREAKDOWN ITEM QTY TANK 3421 TANK GPF GENOVA FILL VALVE V257 1 PARTS BREAKDOWN ITEM QTY PRESSURE ASSIST TORNADO / TORNADO ADA FLUSH VALVE V221 1 PILOT VALVE V183-R 1 COMPLEMENT BAG V FLUSH VALVE V PARTS BREAKDOWN ITEM QTY TANK TO BOWL GASKET V245 1 PARTS BREAKDOWN ITEM QTY COMPLEMENT BAG V PILOT VALVE V121 1 METALIC BOLTS V COMPLEMENT BAG V FLUSH HANDLE AND ARM V191-S 1 FLUSH VALVE V203 1 BOLT CAP V METALIC BOLTS V210 2 METALIC BOLTS V COMPLEMENT BAG V SLOAN 1.28 GPF TANK V276 1 BOLT CAP V FLUSH HANDLE AND ARM V189 1 BOLT CAP V TANK TO BOWL GASKET V245 1 METALIC BOLTS V136 2 TANK 3427 MANCHESTER EL DF TANK TO BOWL GASKET V245 1 BOLT CAP V TANK LID TANK TO BOWL GASKET V245 1 TANK 3466 VIENNA ELX / PARTS BREAKDOWN ITEM QTY VIENNA RF / RHODAS ADA FILL VALVE V121-V 1 TANK 3416 TANK 3420 VELEZZA FLUSH VALVE V181 1 PARTS BREAKDOWN ITEM QTY RHODAS ADA DF / VIENNA EL DF / VIENNA RF DF COMPLEMENT BAG V BALLCOCK VALVE V183-R 1 TANK TO BOWL GASKET V PARTS BREAKDOWN ITEM QTY FLUSH VALVE V PARTS BREAKDOWN ITEM QTY METALIC BOLTS V PILOT VALVE V283 1 COMPLEMENT BAG V PILOT VALVE V333-V 1 BOLT CAP V FLUSH VALVE V181 1 FLUSH HANDLE AND ARM V191-S 1 FLUSH VALVE V COMPLEMENT BAG V METALIC BOLTS V COMPLEMENT BAG V TANK 3130 DELFOS EL -DF TANK TO BOWL GASKET V245 1 BOLT CAP V FLUSH HANDLE AND ARM V189 1 METALIC BOLTS V136 2 TANK TO BOWL GASKET V245 1 METALIC BOLTS V136 2 BOLT CAP V BOLT CAP V PARTS BREAKDOWN ITEM QTY TANK LID TANK TO BOWL GASKET V245 1 TANK 3467 VIENNA ELX / FILL VALVE V257 1 SEAT VIENNA RF / RHODAS ADA FLUSH VALVE V302 1 TANK 3479 SEAT PARTS BREAKDOWN ITEM QTY SPARTA ADA / SPARTA EL / SPARTA RF BALLCOCK VALVE V183-R 1 PARTS BREAKDOWN ITEM QTY FLUSH VALVE V293 1 TANK 3438 FILL VALVE V333-1M 1 COMPLEMENT BAG V RHODAS ADA DF / VIENNA EL DF / VIENNA RF DF FLUSH VALVE V FLUSH HANDLE AND ARM V189-D 1 PARTS BREAKDOWN ITEM QTY FLUSH HANDLE AND ARM V METALIC BOLTS V FILL VALVE V121-V 1 COMPLEMENT BAG V BOLT CAP V FLUSH VALVE V181 1 TANK TO BOWL GASKET V245 1 TANK TO BOWL GASKET V245 1 COMPLEMENT BAG V METALIC BOLTS V TANK TO BOWL GASKET V245 1 BOLT CAP V TANK 3412 METALIC BOLTS V136 2 VIENNA PLUS RF / VIENNA PLUS EL / VIENNA PLUS ADA BOLT CAP V TANK 3425 PARTS BREAKDOWN ITEM QTY MURANO ADA / MURANO EL / MURANO RF PILOT VALVE V333-1V 1 PARTS BREAKDOWN ITEM QTY FLUSH VALVE V FILL VALVE V338-1R 1 COMPLEMENT BAG V FLUSH VALVE V FLUSH HANDLE AND ARM V FLUSH HANDLE AND ARM V METALIC BOLTS V COMPLEMENT BAG V BOLT CAP V TANK TO BOWL GASKET V245 1 TANK TO BOWL GASKET V245 1 METALIC BOLTS V TANK LID BOLT CAP V

111 Spec Seq#: 3. CARE AND MAINTENANCE INSTRUCTIONS CARE AND CLEANING!! The minimum water pressure for the proper functioning of this fixture is 20 psi. The toilet is designed for installation on a 3 or 4 inch diameter drain using the appropriate flange. Never use cement or plaster as a sealant because this could break the bowl. When cleaning your toilet, wash it with mild, soapy water, rinse thoroughly with clear water and dry with a soft cloth. Avoid detergents, disinfectants, or cleaning products in aerosol cans. NEVER use abrasive scouring powders or abrasive pads on your toilet seat. Some bathroom chemicals and cosmetics may damage the seat's finish. WARNING: Do not use in-tank cleaners. Products containing chlorine (calcium hypochlorite) can seriously damage fittings in the tank. This damage can cause leakage and property damage. Vortens shall not be responsible or liable for any tank fitting damage caused by the use of cleaners containing chlorine (calcium hypochlorite) TROUBLESHOOTING IF FILL VALVE SHUTS OFF BUT CONTINUES TO LEAK SLOWLY, perform valve cleaning process. LIFT ARM FIRST IF FILL VALVE TURNS OFF AND ON DURING PERIODS OF NON-USE, it is a signal you are wasting water because: The end of the refill tube is inserted into overflow pipe, below water level in tank. Attach refill tube to overflow pipe using "S" clip provided. IMPORTANT: Always clear sand and rust from system. Make sure water supply is off. Remove valve TOP by lifting arm and rotating top and arm 1/8 turn counterclockwise, pressing down slightly on cap. While holding a container over the uncapped VALVE to prevent splashing, turn water supply on and off a few times. Leave water supply off. Replace TOP by engaging lugs and rotating 1/8 turn clockwise. MAKE CERTAIN TIP IS TURNED TO THE LOCKED POSITION. VALVE MAY NOT TURN ON IF TOP IS NOT FULLY TURNED TO THE LOCKED POSITION. The flush valve is leaking because it's worn, dirty or misaligned with tank ball or flapper (replace with a new flapper). IF FILL VALVE WON'T TURN ON OR SHUT OFF or REFILL OF TANK WATER IS SLOW after valve has been in use for some time, Fluidmaster Model 242 Replacement Seal may be needed. Go to our website at for more solutions to toilet problems. For troubleshooting information please contact: Always use quality Fluidmaster repair parts when maintaining your Fluidmaster products. Fluidmaster shall not be responsible or liable for any damages caused by products used with Fluidmaster valves that were not manufactured by Fluidmaster, Inc Rancho Viejo Road San Juan Capistrano, CA (949) (800) Fluidmaster, Inc. Registered trademark of Fluidmaster, Inc.

112 Spec Seq#: 3 1 INSTALLATION INSTRUCTIONS FOR DUAL FLUSH WITH HANDLE 1 NUT SCREW PLACE WAX SEAL ON TOILET S FLUSH HOLE. SCREW NUT SCREW EXPANDER ADJUSTABLE WRENCH INTAKE VALVE REMOVE TOILET SEAT FROM ITS BOX AND PLACE IT IN NORMAL POSITION ON THE CLOSET FLANGE, WITH THE SCREWS INSIDE ITS BASE; BE SURE IT STANDS STRAIGHT. NEXT, PLACE THE NUTS AND SECURE THEM WELL WITH AN ADJUSTABLE WRENCH. PLACE TOILET SEAT; INSERT SCREWS IN THE HOLES ON SEAT S RIM; TIGHTEN SCREWS UNTIL IT IS WELL SECURED. TIGHTEN SCREWS ALONG WITH EXPANDERS INTO TANK; SIT TANK ON BOWL. GASKET DRAIN VALVE S OVERFLOW TUBE OVERFLOW HOSE FEEDING HOSE HEX NUT WING NUT OVERFLOW HOSE 5 ONCE THE TANK IS PLACED ON THE BOWL, 6 TAKE OVERFLOW TUBE AND THE BASE TO FIX 7 INSERT GASKET AND WASHER ON THE SCREW; THE OVERFLOW TUBE; INSERT ONE END ON ONCE INSERTED, TIGHTEN HEX NUT UNTIL TANK THE INTAKE VALVE TUBE AND THE OTHER END IS WELL SECURED; BE SURE NOT TO ON THE DRAIN VALVE S OVERFLOW TUBE. OVERTIGHTEN FOR IT COULD BREAK THE TANK. WATER SUPPLY LINE TO SUPPLY WATER TO THE TOILET USE A FEEDING HOSE, WHICH HAS TO BE CONNECTED TO THE WATER SUPPLY LINE IN THE FLOOR. WATER LEVEL CONTROL CLIP 14 TO CONTROL WATER LEVEL IN TANK, TAKE 15 BOLT AND TURN IT COUNTERCLOCKWISE TO DECREASE WATER LEVEL AND CLOCKWISE TO INCREASE IT. IMPORTANT: Water level should be exactly as marked in the drain valve s overflow tube in order to flush properly. INSTALL TANK COVER. READY TO WORK! US Office: 1498 Brookpark Drive Mansfield, OH Ph: Fax: customersupport@lamosa.com

113 Spec Seq#: 5 5/8 (1.58 cm) or/o/ou x2 Tools required/hardware kit includes 1 Place seat on bowl Alternate installation instructions for 1.28gpf bowls with restricted space Attach nuts, finger-tighten 2 3 As you hold seat centered on bowl, tighten lower section of STA-TITE nuts until they snap off Prior to seat installation, pre-shear off bottom section of (1) nut using two 5/8 wrenches as shown. Discard lower portion of nut, keeping upper section with integrated washer for installation on restricted acess side of bowl. Do NOT Shear remaining nut at this time. 2 Position sheared off nut directly beneath the side with restricted access bolt hole and as bolt is coming through bolt hole, fingertighten nut to bolt, pulling it through hole as it is being threaded. Fingertighten remaining nut on opposite side of bowl. 3 Holding seat centered on bowl, use a 5/8 wrench to tighten unsheared nut until lower portion of nut shears off. Use an open ended 5/8 wrench and tighten pre-sheared off nut 4-5 quarter turns, this will indicate proper tightening torque. 1

114 WALL HUNG LAVATORY Spec Seq#: 6

115 Spec Seq#: Installation Guide Wall-Mount Lavatories K-2005, K-2006, K-2007 K-2053, K-2054, K-2084 M product numbers are for Mexico (i.e. K-12345M) Los números de productos seguidos de M corresponden a México (Ej. K-12345M) Français, page Français-1 Español, página Español B

116 Spec Seq#: 7 Tools and Materials Thank You For Choosing Kohler Company We appreciate your commitment to Kohler quality. Please take a few minutes to review this manual before you start installation. If you encounter any installation or performance problems, please don t hesitate to contact us. Our phone numbers and website are listed on the back cover. Thanks again for choosing Kohler Company Before You Begin Observe all local plumbing and building codes. Prior to installation, unpack the new lavatory and inspect it for damage. Return the lavatory to its protective carton until you are ready to install it. Inspect the drain and supply tubing. Replace if necessary. These instructions are for installing the lavatory to wood frame construction. For other installations, supply suitable bracing and fastening devices of sufficient size and strength. The walls and floor must be square, plumb, and level B 2 Kohler Co.

117 Spec Seq#: 7 1. Preparation Install the water supplies and drain piping according to the roughing-in information. Install sufficient backing behind the finished wall to provide a secure material for the anchoring devices Hanger (provided) Installation Install the hanger according to the roughing-in information. Use 1/4 lag bolts and washers (neither is provided) or other suitable fasteners to secure the hanger to the finished wall and backing material. Make sure the hanger is level. Concealed Arm Carrier Installation Install the concealed arm carrier according to the roughing-in information. Follow the installation information included with the carrier. Make sure the carrier is level. Kohler Co B

118 Spec Seq#: 7 2. Install the Lavatory Install the faucet and drain to the lavatory according to the manufacturer s instructions Installation With Hanger Temporarily position the lavatory on the hanger, and level. Use a pencil to mark the anchoring hole locations on the finished wall. Remove the lavatory. Drill 1/4 mounting holes at the marked locations on the wall. CAUTION: Risk of product damage. Do not overtighten the hardware. Overtightening may damage the product. Position the lavatory on the hanger, and level. Use 3/8 lag bolts and washers (not provided) to secure the lavatory to the finished wall and backing material. Connect and tighten the trap to the drain, and complete the water supply connections to the faucet according to the instructions packed with the faucet. Run water into the lavatory and check for leaks. Clean up with a non-abrasive cleaner. Installation With Concealed Arm Carrier CAUTION: Risk of product damage. Do not overtighten the hardware. Overtightening may damage the product B 4 Kohler Co.

119 Spec Seq#: 7 Install the Lavatory (cont.) Slide the lavatory completely onto the carrier arms. Adjust the level of the lavatory by turning the front and rear carrier arm screws in or out as needed. The lavatory should not rock after it has been leveled. Carefully tighten the toggle screws until the lavatory is securely held in place. Connect and tighten the trap to the drain, and complete the water supply connections to the faucet according to the instructions packed with the faucet. Run water into the lavatory and check for leaks. Clean up with a non-abrasive cleaner Kohler Co B

120 ONE-YEAR LIMITED WARRANTY KOHLER plumbing products are warranted to be free of defects in material and workmanship for one year from date of installation. Kohler Co. will, at its election, repair, replace or make appropriate adjustment where Kohler Co. inspection discloses any such defects occurring in normal usage within one (1) year after installation. Kohler Co. is not responsible for removal or installation costs. Use of in-tank toilet cleaners will void the warranty. To obtain warranty service contact Kohler Co. either through your Dealer, Plumbing Contractor, Home Center or E-tailer, or by writing Kohler Co., Attn: Customer Service Department, 444 Highland Drive, Kohler, WI 53044, USA, or by calling KOHLER ( ) from within the USA, from within Canada and from within Mexico. IMPLIED WARRANTIES INCLUDING THAT OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. KOHLER CO. AND/OR SELLER DISCLAIMS ANY LIABILITY FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states/provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of special, incidental or consequential damages, so these limitations and exclusions may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state/province to state/province. This is Kohler Co.'s exclusive written warranty. KOHLER PRO Cook Cooking Vessel FIVE-YEAR LIMITED WARRANTY Kohler PRO Cook cooking vessels installed in residential settings are warranted to be free of defects in material and workmanship for five (5) years from the date of installation. The KOHLER PRO Cook cooking vessels used in commercial settings are warranted to be free of defects in material and workmanship for one (1) year from the date of installation under Kohler Co.'s one-year limited warranty. The sink components of the PRO CookCenter and PRO CookSink are covered by Kohler Co.'s one-year limited warranty. If a defect is found in normal residential usage, Kohler Co. will, at its election, repair, replace, or make appropriate adjustment where Kohler Co. inspection discloses any such defects. Damage caused by accident, misuse or abuse is not covered by this warranty. Kohler Co. is not responsible for labor charges, removal charges, installation, or other incidental or consequential costs. In no event shall the liability of Kohler Co. exceed the purchase price of the product. To obtain warranty service contact Kohler Co., either through your Dealer, Plumbing Contractor, Home Center or E-tailer, or by writing: Kohler Co., Attn: Customer Service Department, 444 Highland Drive, Kohler, WI 53044, USA, or by calling KOHLER ( ) from within the USA, from within Canada and from within Mexico. KOHLER CO. AND/OR SELLER ARE PROVIDING THIS WARRANTY IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. KOHLER CO. AND/OR SELLER DISCLAIM ALL LIABILITY FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states/provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of special, incidental or consequential damages, so these limitations and exclusions may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state/province to state/province.

121 Spec Seq#: 8 WARRANTY INFORMATION Mainline products will be covered by IPS Corporation s limited warranty. It is as follows: IPS Corporation ( IPS Corp. ) warrants to all original purchasers of IPS Corp. products that all new IPS Corp. products shall be of good quality and free from defects in material and workmanship for the product s shelf life. If any IPS Corp. product becomes defective, or fails to conform to this written limited warranty under normal use and storage conditions, and if the original purchaser complies with the terms of this limited warranty, then IPS Corp. will, without charge, replace the nonconforming product. This limited warranty shall extend to all products manufactured and sold by IPS Corp. However, this limited warranty shall not extend to, nor shall IPS Corp. be responsible for, damages or loss resulting from accident, misuse, negligent use, improper application, or incorporation of IPS Corp. products into other products. In addition, any repackaging of IPS Corp. products also shall void the limited warranty provided herein. Hajoca locations can contact their IPS Sales Agents or IPS Customer Service directly to report suspected defective products Specific Brand Warranty Statements: WELD-ON. All IPS products are intended for use by skilled individuals at their own risk. Any suggestions or recommendations we give are based on information and results from our in house laboratory testing. Therefore, installers should verify for themselves that they can make satisfactory joints under varying conditions, making sure that installation method and products used are suited for their application. Please contact us for additional information or instruction media. Since specific use, materials and handing are not controlled by IPS Corporation; our warranty is limited to the replacement of defective IPS products. WATER-TITE & GUY GRAY. Water-Tite Product s warranty shall be limited to replacement or credit not to exceed the original invoice price. IPS shall not be liable for installation or labor costs. All IPS merchandise is guaranteed against defects in materials or workmanship for a period of one year from the date of purchase. Determination of a product s condition (defective or not) shall remain the sole right of IPS Corporation and any such determination will be final. STUDOR. All Studor products carry a limited life time warranty which guarantees against defects resulting from faulty workmanship or materials. If any such product is found to be defective by reason of faulty workmanship or material, upon written notice and return of the product(s), the defective product will be replaced by Studor free of charge, including shipping charges for the replacement product(s). Claims for labor costs and other expenses required to replace such defective product(s) or to repair any damage resulting from the use thereof will not be allowed by Studor. Our liability is limited to the price paid for the defective product(s). Studor will not be bound by any warranty other than above set forth, unless such warrant is in writing. TEST-TITE. IPS Corporation warrants each pneumatic test plug to be free from defects in materials and workmanship for a period of THREE (3) Years from the date of manufacture, under normal use and service. This warranty does not apply to any goods which have been subjected to misuse, mishandling, misapplication, neglect or repair other than by the manufacturer. If any pneumatic test plug is returned to IPS Corporation in Collierville, TN and if upon examination, IPS Corporation finds to its satisfaction that such pneumatic test plug is defective, IPS Corporation will replace the product at no cost. IPS Corporation is not responsible for any special, indirect, incidental or consequential damages(including, but not limited to damages for loss of business profits, opportunity, information, interruption or other pecuniary loss), arising out of or relating to the use, abuse or misuse of Test-Tite products, even if IPS Corporation has been advised of the possibility of such damages IPS Corporations liability to the customer or any third person or party in all instances shall be limited to the actual purchase price of the defective Test-Tite product. The warranty herein made is in lieu of other warranties, expressed, implied in fact or implied by law and without the generality of forgoing disclaimer, is specifically in lieu of all implied warranties of quality or fitness for purpose. Except as expressly set forth herein, the customer assumes the entire risk as to the acceptability, quality and performance of the Test-Tite products and any decision made or actions taken with respect to such Test-Tite products.

122 Spec Seq#: 8 TRUEBRO. Truebro warrants its products against defective material and manufacture, (but not defective installation), for one year after installation. Truebro s liability under this warranty shall be limited to the repair or replacement of the defective product. There shall be no other remedy available, including without limitation, recovery for incidental or consequential damages, injury to person or property, or any other incidental or consequential loss. The preceding warranty shall be IN LIEU of any other warranty, express or implied, including without limitation, any implied warranty of MERCHANTABILITY or fitness for a particular purpose. Some states do not allow the exclusion or limitation on the period of warranty or incidental or consequential damages. AB&A. AB&A products are carefully inspected for manufacturing defects; however, it is not always possible to detect hidden defects. Said products are warranted only to the extent that Seller will replace without charge, products proved to have manufacturing defects within 6 months of the date of delivery thereof and provided Seller has been given an opportunity to inspect the product alleged to be defective and the installation or use thereof. NO WARRANTY IS INCLUDED AGAINST ANY EXPENSE FOR REMOVAL, REINSTALLATION OR OTHER CONSEQUENTIAL DAMAGES ARISING FROM ANY DEFECT. THE WARRANTIES SET OUT ABOVE ARE THE ONLY WARRANTEIS MADE BY SELLER AND ARE EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS OR A PARTICULAR PURPOSE CAUTION: Threaded joints should not be excessively tightened. Use thread compounds specifically intended either for ABS or PVS assembly, as the case may be, DO NOT use linseed oil putty products for thread lubricant. Many oil based putty compounds are not compatible with plastics. SPECIAL FINISHES: Limited Warranty: IPS Corporation warrants that its products are free from defects in materials and workmanship for a period of 6 months. All PVD finishes (including Satin, Nickel, and Polished Brass), are warranted for 15 years against corrosion, tarnishing or discoloring. This warranty does not cover damage due to normal wear and tear, misuse, hard water, improper storage, improper installation, and improper maintenance. Weathered finishes and uncoated finishes such as Oil Rubbed Bronze and Venetian Bronze naturally change over time. Weathered and uncoated finishes are not warranted. Chrome Plated Drain finishes on kitchen, bath, or lavatory drains are warranted for (1) year from date of purchase by the original purchaser. Claims: All claims for defective products, shipment shortages, and billing errors must be made within one week after receipt of goods. Claims should be submitted to your authorized dealer for local manufacturer representative. To locate your local manufacturer representative, please call Installation: Decorative items should be the last items to be installed after cleaning of the surrounding areas. Care and Cleaning of Special Finishes: Use a soft cloth with water to clean. Do not use Abrasives, Caustic cleaning agents or acid based products, for they may permanently damage the finish and void the warranty.

123 Spec Seq#: 9 211E-CP Installation / Installation / Instalación 4" Centerset Lavatory Faucet Robinet de lavabo monopièce, entraxe de 4 po Grifo para lavabo, distancia de 4" Tools You Will Need / Outils dont vous aurez besoin / Herramientas necesarias Adjustable Wrench Pipe Tape Silicone Sealant Clé à molette Ruban pour tuyau Enduit d étanchéité au silicone Llave ajustable Cinta selladora para rosca Sellador de silicona INSTALLATION TIPS Mainline suggests using a locally licensed plumber for installation. Cover your drain to avoid losing parts. This product is engineered to meet the EPA WaterSense flow requirement. The flow rate is governed by the flow controller. If replacement is ever required, be sure to replace it with a WaterSense compliant flow controller to retain the water conserving flow rate of this product. CONSIGNES DE INSTALLATION Mainline suggère de confier l installation à un plombier qualifié pour exercer dans cette région. Couvrir le drain pour ne pas perdre des pièces. Ce produit est conçu pour respecter les exigences de débit d eau du programme WaterSense de l EPA. Le débit est réglé par le régulateur. Si une pièce doit être remplacée, assurez-vous d'utiliser un régulateur de remplacement conforme à WaterSense afin de conserver le taux de débit de ce produit. CONSEJOS DE INSTALLACIÓN Mainline sugiere usar los servicios de un plomero local autorizado para la instalación. Tape la boca del desagüe para prevenir la pérdida de piezas pequeñas. Este producto está diseñado para cumplir con los requerimientos de flujo de EPA WaterSense. El caudal se rige por el controlador de flujo. Si el reemplazo es necesario, asegúrese de reemplazarlo con un controlador de flujo compatible con WaterSense para retener el caudal de conservación de agua de este producto. Revised 11/14/2017

124 Spec Seq#: E-CP 1 Installation / Installation / Instalación Please keep aerator wrench to allow for removal and cleaning of aerator. Garder la clé pour brise-jet pour retirer l aérateur afin de le nettoyer. Conserve la llave para aireador para quitar y limpiar el aireador. Revised 11/14/2017

125 Spec Seq#: 9 211E-CP Installation / Installation / Instalación Troubleshooting / Dépannage / Guía de solucionar problemas If you ve followed the instructions carefully and your faucet still does not work properly, take these corrective steps. Si vous avez suivi attentivement les instructions et que votre robinet ne fonctionne toujours pas correctement, apporter les correctifs suivants. Si usted ha seguido las instrucciones cuidadosamente y su grifo todavía no funciona correctamente, siga estos pasos correctivos. Problem / Problème / Problema Cause / Cause / Causa Action / Correctif / Solución Leaks underneath handle. Retainer nut has come loose. O-ring is dirty or damaged. Tighten the retainer nut. Clean or replace O- ring Fuites sous la poignée. Goteo debajo de la manija. Aerator leaks or has an inconsistent water flow pattern. Le brise-jet fuit ou la diffusion des jets n est pas uniforme. El aireador gotea o el chorro de agua está irregular. L écrou de fixation s est desserré. Le joint torique est sale ou endommagé. La tuerca de ajuste se ha aflojado. La arandela circular está sucia o dañada. Aerator is dirty or misfitted. Le brise-jet est sale ou mal ajusté. El aireador está sucio o mal puesto. Serrer l écrou de fixation. Nettoyer ou remplacer le joint torique. Apriete la tuerca de ajuste. Limpie o reemplace la arandela circular. Unscrew aerator, remove any debris, check seating of rubber seal then re-assemble aerator. Dévisser le brise-jet, le nettoyer, vérifier l assise du joint en caoutchouc et remettre le brise-jet en place. Destornille el aireador, límpielo, revise el asiento del empaque de goma, y vuelva a ensamblar el aireador. Revised 11/14/2017

126 Spec Seq#: 9 211E-CP Installation / Installation / Instalación Replacement Parts / Pièces de rechange / Repuestos No. Description Part No. 1 Metal Handle / Manette en métal / Manija metálicas A069549* 2 Index Button-Cold/Hot / Repère de température - froid/chaud / Indicador de temperatura- caliente/fría A66D567 3 Locking Nut / Écrou de blocage / Contratuerca A Trim Cap/ Capuchon de garniture/ Tapa ornamental A103022* 5 Ball Valve Assembly / Assemblage de bille / Conjunto de la válvula de bola A66D641N 6 Seat & Spring / Siège et ressort / Asiento y resorte A Aerator Wrench / Clé pour brise-jet / Llave para aireador A031001NI 8 Aerator / Brise-jet / Aireador A500267N-64* 9 Mounting Hardware / Matériel de fixation / Ferretería de montaje A * please indicate finish for these parts Need Help? Please call our toll-free customer service line at for additional assistance or service. Besoin d aide? Veuillez communiquer avec notre service à la clientèle au numéro gratuit pour tous renseignements ou services complémentaires. Requiere asistencia? Llame a nuestro Servicio al Cliente, sin costo, al para asistencia adicional o servicio. Revised 11/14/2017

127 Spec Seq#: 9 Mainline Faucet Warranty MAINLINE warrants that for a period of five years from purchase by the original consumer purchaser, the Product will be free of all defects in material and workmanship that would impair the intended and proper use of the product. If the Product is installed in a commercial application, the above mechanical warranty shall be limited to a period of five years from the date of purchase of the Product. MAINLINE warrants against deterioration of the product s finish for a period of five years from purchase by the original consumer purchaser. If the Product is installed in a commercial application, the above finish warranty shall be limited to a period of five years from the date of purchase of the Product If a defect is found in normal use during the warranty period, MAINLINE will, at Mainline s election, repair the Product, or provide a replacement part or product. Repair or replacement of the Product is the sole and exclusive remedy. Damage caused by the defect (other than to the Product itself) or by accident, misuse, or abuse is not covered by this warranty. Proof of purchase (original sales receipt) must be provided to MAINLINE with all warranty claims. MAINLINE is not responsible for indirect, incidental, consequential damages incurred in installation, repair, or replacement of the faucet. In no event shall the liability of MAINLINE exceed the purchase price of the Product. Any damages to this faucet as a result of misuse, abuse, or neglect or any use of other than genuine MAINLINE replacement parts WILL VOID THE WARRANTY. This warranty is to the original consumer purchaser only, and excludes product damage due to installation error, product abuse, or product misuse, whether performed by a contractor, service company, or the consumer. THIS IS THE SOLE AND EXCLUSIVE WARRANTY BY MAINLINE, WHICH DOES NOT MAKE ANY OTHER WARRANTY OF ANY KIND, INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. MAINLINE DISCLAIMS ANY LIABILITY FOR SPECIAL, INCIDENTAL, EXEMPLARY, PUNITIVE OR CONSEQUENTIAL DAMAGES EVEN IF ADVISED OF THE POSSIBILITY OF THE SAME. Some states do not allow the exclusion or limitation of implied warranties or the incidental consequential or other damages set forth above, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. This warranty applies only to MAINLINE faucets installed in the United States of America and Canada. If you have any questions or concerns regarding our warranty plan, please call MAINLINE recommends using a professional plumber for all installation and repair.

128 URINAL Spec Seq#: 10

129 Spec Seq#: 11 Installation Guide Guide d installation Guía de instalación See the roughing-in illustration on the opposite page. Se reporter à l'illustration se trouvant sur la page opposée. Consulte el diagrama de instalación en la página opuesta. Thread Sealant Ruban d'étanchéité pour filetage Cinta selladora de roscas Plus: Hole Cutting Equipment Et: Outil à découper Más: Herramientas para perforar orificios Record your model number below for future reference: Consigner le numéro de modèle ci-dessous pour toute référence ultérieure: Anote abajo el número de su modelo como referencia futura: For service parts information, visit For care and cleaning and other information, visit Pour tout renseignement sur les pièces de rechange, visiter Pour tout renseignement sur l'entretien, le nettoyage et autre, visiter Para consultar información sobre piezas de repuesto, visite Para el cuidado y la limpieza, y más información, visite Important Information The urinal complies with ADA requirements when the rim is mounted no higher than 17 (432 mm) from the finished floor. Informations importantes L'urinoir est conforme aux exigences ADA lorsque le rebord n'est pas monté à plus de 17 (432 mm) du plancher fini. Información importante * El mingitorio cumple los requisitos de la ADA cuando el reborde se instala a una altura no mayor de 17 (432 mm) del piso acabado. 1 Turn off the water. Couper l'arrivée d'eau. Cierre el agua. 2 Install a backer board for additional support. Installer une planche d'appui pour obtenir un support supplémentaire. Instale una tabla de refuerzo como soporte adicional Single bracket installation: Install the wall hanger. Installation de support unique: Installer l'étrier mural. Instalación de un solo soporte: Instale el soporte de suspensión mural. Double bracket installation: Install the wall hangers. Installation de support double: Installer les étriers muraux. Installation de support double: Installer les étriers muraux. 4 Apply thread sealant tape. Install the collar and gasket. Appliquer du ruban d'étanchéité pour filets. Installer le collier et le joint statique. Aplique cinta selladora de roscas. Instale el collarín y el empaque. 5 Position the urinal on the hanger(s). Positionner l'urinoir sur le(s) étrier(s). Coloque el mingitorio en los soportes de suspensión. 6 Secure the urinal to the collar using the screws and washers. Sécuriser l'urinoir sur le collier en utilisant les vis et les rondelles. Fije el mingitorio al collarín con los tornillos y las arandelas. 7 Install the flush valve following the manufacturer's instructions. Installer le robinet de chasse conformément aux instructions du fabricant. Instale la válvula de descarga de acuerdo a las instrucciones del fabricante. 8 Turn on the water supply. Ouvrir l'arrivée d'eau. Abra el suministro de agua. 9 Check for leaks. Rechercher des fuites. Verifique que no haya fugas D

130 K-4972 = 1-1/4" Spud K-4972 = Raccord de 1-1/4" K-4972 = Spud de 1-1/4" A Finished Wall Mur fini Pared acabada 2" NPT Tap Trou taraudé de 2" NPT Rosca NPT de 2" 3/4" Spud Raccord de 3/4" Spud de 3/4" B E D 3/4" Spud Raccord de 3/4" Spud de 3/4" 2" NPT Tap Trou taraudé de 2" NPT Rosca NPT de 2" R K-4972 = 1-1/4" Spud K-4972 = Raccord de 1-1/4" K-4972 = Spud de 1-1/4" B E D H F G Wall Hangers Supports muraux Soportes de suspensión mural I J 2" NPT Tap Trou taraudé de 2" NPT Rosca NPT de 2" Spec Seq#: 11 1/4" (6 mm) 6" (152 mm) C 24" (610 mm) *17 (432 mm) C 24" (610 mm) *17 (432 mm) Finished Floor Sol fini Piso acabado Outlet Detail Détail sortie Detalle de la salida A R B C D E F G H I J K-4904-ET K-4904-ER K-4960-ET K-4960-ER K-4972-ET K-4972-ER K-4989-T K-4989-R K-4991-ET K-4991-ER K-5016-ET K-5016-ER 3" (76 mm) NA 3" (76 mm) NA 2-1/4" (57 mm) NA 2-1/4" (57 mm) NA 3" (76 mm) NA 2-3/8" (60 mm) NA NA 20-3/4" (527 mm) NA 20-3/8" (518 mm) NA 19-1/4" (489 mm) NA 19-1/4" (489 mm) NA 20-3/4" (527 mm) NA 16-1/8" (410 mm) 14-1/8" (359 mm) 14-1/8" (359 mm) 14-1/8" (359 mm) 14-1/8" (359 mm) 14-1/2" (368 mm) 14-1/2" (368 mm) 12-1/2" (318 mm) 12-1/2" (318 mm) 14-1/8" (359 mm) 14-1/8" (359 mm) 14-1/2" (368 mm) 14-1/2" (368 mm) 21" (533 mm) 21" (533 mm) 21" (533 mm) 21" (533 mm) 22-1/8" (5262 mm) **14-1/8" (359 mm) 22-1/8" (5262 mm) **14-1/8" (359 mm) 17-1/4" (438 mm) 17-1/4" (438 mm) 21" (533 mm) 21" (533 mm) 17-1/2" (445 mm) **9-1/2" (241 mm) 17-1/2" (445 mm) **9-1/2" (241 mm) 3" (76 mm) 3" (76 mm) 3" (76 mm) 3" (76 mm) NA NA 6-3/4" (171 mm) 6-3/4" (171 mm) 3" (76 mm) 3" (76 mm) 6-1/2" (165 mm) 6-1/2" (165 mm) 19" (483 mm) 19" (483 mm) 19" (483 mm) 19" (483 mm) 19-1/8" (486 mm) 19-1/8" (486 mm) 14-1/4" (362 mm) 14-1/4" (362 mm) 19" (483 mm) 19" (483 mm) 11-3/8" (289 mm) 11-3/8" (289 mm) 18" (457 mm) 18" (457 mm) 18" (457 mm) 18" (457 mm) 18-1/4" (464 mm) 18-1/4" (464 mm) 16-1/4" (413 mm) 16-1/4" (413 mm) 18" (457 mm) 18" (457 mm) 13-1/2" (343 mm) 13-1/2" (343 mm) 12" (305 mm) 12" (305 mm) 12" (305 mm) 12" (305 mm) 12" (305 mm) 12" (305 mm) 10" (254 mm) 10" (254 mm) 12" (305 mm) 12" (305 mm) 6-1/2" (165 mm) 6-1/2" (165 mm) 26-7/8" (683 mm) 26-7/8" (683 mm) 28" (711 mm) 28" (711 mm) 27-5/8" (702 mm) 27-5/8" (702 mm) 24" (610 mm) 24" (610 mm) 26-7/8" (683 mm) 26-7/8" (683 mm) 20-3/8" (518 mm) 20-3/8" (518 mm) 40-1/2" (1029 mm) 40-1/2" (1029 mm) 40-1/2" (1029 mm) 40-1/2" (1029 mm) 40-1/8" (1019 mm) 40-1/8" (1019 mm) 35-1/2" (902 mm) 35-1/2" (902 mm) 40-1/2" (1029 mm) 40-1/2" (1029 mm) 32-1/2" (826 mm) 32-1/2" (826 mm) NA NA NA NA NA NA NA NA NA NA NA NA K-5452-ET 2-3/8" (60 mm) NA 14-3/4" (375 mm) 17-1/2" (445 mm) **9-1/2" (241 mm) 6-1/2" (165 mm) 11-3/4" (298 mm) 13-3/4" (349 mm) NA 20-3/4" (527 mm) NA 30" (762 mm) K-5452-ER NA 16-1/4" (413 mm) 14-3/4" (375 mm) 17-1/2" (445 mm) **9-1/2" (241 mm) 6-1/2" (165 mm) 11-3/4" (298 mm) 13-3/4" (349 mm) NA 20-3/4" (527 mm) NA 30" (762 mm) *Maximum rim height for ADA compliance. *Hauteur maximum de rebord conforme à l'ada. *Altura máxima del borde para cumplir con los requisitos de la ADA. **Maximum outlet height for ADA compliance. **Hauteur de sortie maximum conforme à l'ada. **Altura máxima de la salida para cumplir con los requisitos de la ADA. Need help? Contact the KOHLER Customer Care Center at KOHLER ( ). For service parts information, visit For care and cleaning and other information, visit ONE-YEAR LIMITED WARRANTY KOHLER plumbing products are warranted to be free of defects in material and workmanship for one year from date of installation. Kohler Co. will, at its election, repair, replace or make appropriate adjustment where Kohler Co. inspection discloses any such defects occurring in normal usage within one (1) year after installation. Kohler Co. is not responsible for removal or installation costs. Use of in-tank toilet cleaners will void the warranty. To obtain warranty service contact Kohler Co. either through your Dealer, Plumbing Contractor, Home Center or E-tailer, or by writing Kohler Co., Attn.: Customer Care Center, 444 Highland Drive, Kohler, WI 53044, USA, or by calling KOHLER ( ) from within the USA and Canada, and from within Mexico, or visit within the USA, from within Canada, or in Mexico. IMPLIED WARRANTIES INCLUDING THAT OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. KOHLER CO. AND/OR SELLER DISCLAIM ANY LIABILITY FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states/provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of special, incidental or consequential damages, so these limitations and exclusions may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state/province to state/province. This is Kohler Co.'s exclusive written warranty. Besoin d'aide? Appeler le centre de services à la clientèle de KOHLER au KOHLER ( ). Pour tout renseignement sur les pièces de rechange, visiter Pour tout renseignement sur l'entretien, le nettoyage et autre, visiter GARANTIE LIMITÉE D'UN AN Les produits de plomberie KOHLER sont garantis contre tout vice de matériau et de fabrication pendant un an à partir de la date de l'installation. Si un vice est découvert au cours d'une utilisation normale, Kohler Co. choisira, à sa discrétion, la réparation, le remplacement ou la rectification appropriée après inspection desdits vices par Kohler Co. pendant un (1) an à partir de la date d'installation. Kohler Co. n'est pas responsable des frais d'enlèvement ou d'installation. L'utilisation de nettoyants à l'intérieur du réservoir annule la garantie. Pour obtenir le service de garantie, contacter Kohler Co., par l'intermédiaire du vendeur, plombier, centre de rénovation ou revendeur par internet, ou bien par écrit à l'adresse suivante Kohler Co., Attn.: Customer Care Center, 444 Highland Drive, Kohler, WI 53044, USA, ou en appelant le KOHLER ( ) à partir des É.-U. et du Canada, et le à partir du Mexique, ou consulter le site aux É.-U., à partir du Canada, ou au Mexique. LES GARANTIES TACITES,Y COMPRIS CELLES DE COMMERCIALITÉ ET D'ADAPTATION À UN USAGE PARTICULIER, SONT EXPRESSÉMENT LIMITÉE À LA DURÉE DE LA PRÉSENTE GARANTIE. KOHLER CO. ET/OU LE REVENDEUR DÉCLINENT TOUTE RESPONSABILITÉ CONTRE LES DOMMAGES PARTICULIERS, ACCESSOIRES OU INDIRECTS. Certains états et provinces ne permettent pas de limite sur la durée de la garantie tacite, ni l'exclusion ou la limite des dommages particuliers, accessoires ou indirects, et, par conséquent, lesdites limites et exclusions peuvent ne pas s'appliquer à votre cas. Cette garantie vous donne des droits juridiques particuliers. Vous pouvez également avoir d'autres droits qui varient d'un état ou d'une province à l'autre. Ceci constitue la garantie écrite exclusive de Kohler Co. Necesita ayuda? Comuníquese con el Centro de Atención al Cliente de KOHLER al KOHLER ( ). Para consultar información sobre piezas de repuesto, visite Para el cuidado y la limpieza, y más información, visite GARANTÍA LIMITADA DE UN AÑO Se garantizan los productos de plomería KOHLER contra defectos de material y mano de obra durante un año a partir de la fecha de instalación. Kohler Co., a su criterio, reparará, reemplazará o realizará los ajustes pertinentes en los casos en que la inspección realizada por Kohler Co. determine que dichos defectos hayan ocurrido durante el uso normal en el transcurso de un (1) año a partir de la fecha de instalación. Kohler Co. no se hace responsable de costos de desinstalación o de instalación. El uso de limpiadores de inodoro que se colocan dentro del tanque anula la garantía. Para obtener el servicio de garantía, comuníquese con Kohler Co. a través de su distribuidor, contratista de plomería, centro de remodelación o distribuidor por Internet, o escriba a Kohler Co., Atención: Customer Care Center, 444 Highland Drive, Kohler, WI 53044, EE.UU., o llame al KOHLER ( ) desde los EE.UU. y Canadá, o al desde México, o visite desde los EE.UU., desde Canadá, o en México. TODA GARANTÍA IMPLÍCITA, INCLUIDA LA DE COMERCIALIZACIÓN E IDONEIDAD DEL PRODUCTO PARA UN USO DETERMINADO, SE LIMITA EXPRESAMENTE A LA DURACIÓN DE ESTA GARANTÍA. KOHLER CO.Y/O EL VENDEDOR DESCARGAN TODA RESPONSABILIDAD POR CONCEPTO DE DAÑOS PARTICULARES, INCIDENTALES O INDIRECTOS. Algunos estados/provincias no permiten limitaciones en cuanto a la duración de una garantía implícita o a la exclusión o limitación de daños particulares, incidentales o indirectos, por lo que estas limitaciones y exclusiones pueden no aplicar a su caso. Esta garantía le otorga ciertos derechos legales específicos. Además, usted también puede tener otros derechos que varían de estado a estado y de provincia a provincia. Esta es la garantía exclusiva por escrito de Kohler Co. USA/Canada: KOHLER Mexico: D 2015 Kohler Co.

131 Spec Seq#: 12 Code No Rev. 2 (04/14) INSTALLATION INSTRUCTIONS FOR EXPOSED REGAL XL WATER CLOSET AND URINAL FLUSHOMETERS Closet Flushometer 1½ (38 mm) Top Spud MODELS 110/111, 113, 115 & 116 Closet Flushometer 1½ (38 mm) Back Spud MODEL 120 & 122 Service Sink Flushometer 1½ (38 mm) Top Spud MODEL 117 Urinal Flushometer 1¼ (32 mm) Top Spud MODEL 180 Urinal Flushometer ¾ (19 mm) Top Spud MODEL 186 Squat Toilet Flushometer 1½ (38 mm) Back Spud MODEL LIMITED WARRANTY Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material and workmanship for a period of three (3) years (one (1) year for special finishes, SF faucets, PWT electronics and 30 days for PWT software) from date of first purchase. During this period, Sloan Valve Company will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this warranty under normal use and service. This shall be the sole and exclusive remedy under this warranty. Products must be returned to Sloan Valve Company, at customer s cost. No claims will be allowed for labor, transportation or other costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company s products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER. PRIOR TO INSTALLATION Before you install the Regal XL flushometer, be sure the items listed below are installed. Also, refer to the rough-in diagrams on the next page. Closet or urinal fixture Drain line Water supply line IMPORTANT: INSTALL ALL PLUMBING IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS. WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE VOLUME OF WATER FOR EACH FIXTURE. FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS. Sloan s flushometers are designed to operate with 10 to 100 psi (69 to 689 kpa) of water pressure. THE MINIMUM PRESSURE REQUIRED TO THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED. Consult fixture manufacturer for minimum pressure requirements. Most Low Consumption water closets (1.6 gpf/6.0 Lpf) require a minimum flowing pressure of 25 psi (172 kpa). TOOLS REQUIRED FOR INSTALLATION Straight blade screwdriver Sloan A-50 Super-Wrench, Sloan A-109 Plier Wrench or smooth jawed spud wrench

132 Spec Seq#: 12 VALVE ROUGH-INS MODELS 110/111 MODELS 113, 115 & 116 NOTE: Water Closet Valves with -2.4 Model Designation deliver 2.4 gpf (9.0 Lpf) MODEL 117 MODELS 120/ MODEL 180 MODEL 186 NOTE: Model 180 requires 1 I.P.S. (DN 25 mm) Supply LIVE TEXT 1 Control Stop is available with Whitworth Thread Model 122 IMPORTANT NOTES: When mounted on an ADA accessible bowl, the rough-in to the supply inlet should be no higher than 37½ or the handle will exceed maximum height allowances under ADA guidelines. New ADAAG Guidelines allow for Split or Offset Grab Bars, check with local authorities or reference section of ADAAG. 2

133 Spec Seq#: 12!!! IMPORTANT!!! WITH THE EXCEPTION OF CONTROL STOP INLET, DO NOT USE PIPE SEALANT OR PLUMBING GREASE ON ANY VALVE COMPONENT OR COUPLING!!!! IMPORTANT!!! PROTECT THE FINISH OF SLOAN S FLUSHOMETERS DO NOT USE TOOTHED TOOLS TO INSTALL OR SERVICE THESE VALVES. USE A SLOAN A-50 Super- Wrench, Sloan A-109 PLIER WRENCH OR SMOOTH JAWED SPUD WRENCH TO SECURE ALL COUPLINGS. SEE CARE AND CLEANING SECTION.!!! IMPORTANT!!! THIS PRODUCT CONTAINS MECHANICAL AND/OR ELECTRICAL COMPONENTS THAT ARE SUBJECT TO NORMAL WEAR. THESE COMPONENTS SHOULD BE CHECKED ON A REGULAR BASIS AND REPLACED AS NEEDED TO MAINTAIN THE VALVE S PERFORMANCE. A Measure from finished wall to C/L of Fixture Spud. Cut pipe 1¼ (32 mm) shorter than this measurement. Chamfer O.D. and I.D. of water supply pipe. B Slide Threaded Adapter fully onto pipe.!!! IMPORTANT!!! NEVER OPEN CONTROL STOP TO WHERE THE FLOW FROM THE VALVE EXCEEDS THE FLOW CAPABILITY OF THE FIXTURE. IN THE EVENT OF A VALVE FAILURE, THE FIXTURE MUST BE ABLE TO ACCOMMODATE A CONTINUOUS FLOW FROM THE VALVE.!!! IMPORTANT!!! LAWS AND REGULATIONS PROHIBIT THE USE OF HIGHER FLUSHING VOLUMES THAN LISTED ON FIXTURE OR FLUSHOMETER. Please take the time to read this manual to ensure proper product installation and longevity. Also, please visit our website to download our most recent documentation for this product. If you have questions about how to install your Flushometer, consult your local Sloan Representative or call Sloan Technical Support at: SLOAN-14 ( ) 1 - INSTALL SWEAT SOLDER ADAPTER (ONLY IF YOUR SUPPLY PIPE DOES NOT HAVE A MALE THREAD) WATER SUPPLY PIPE FINISHED WALL 1-1/4 (32 mm) C Sweat solder the Adapter to pipe. SWEAT SOLDER ADAPTER A B C Measure from finished wall to first thread of adapter or threaded supply pipe (dimension X ). Cut cover tube to this length. Slide cover tube over pipe. Slide wall flange over cover tube until against wall. Thread Control Stop onto pipe. Tighten with a wrench making sure outlet is positioned as required. SUPPLY FLANGE SETSCREW WATER SUPPLY PIPE X SETSCREW IRON PIPE NIPPLE OR COPPER PIPE WITH SWEAT SOLDER ADAPTER COVER TUBE H-700 SERIES STOP SWEAT SOLDER ADAPTER COVER TUBE WALL FLANGE BAK-CHEK CONTROL STOP 3 E F G C/L OF FIXTURE SPUD 2 - INSTALL COVER TUBE, WALL FLANGE AND CONTROL STOP TO SUPPLY PIPE AND INSTALL VACUUM BREAKER FLUSH CONNECTION COVER TUBE AND CAST SUPPLY FLANGE WITH SETSCREW ARE AVAILABLE IN YBYC SWEAT SOLDER KIT. D PLUG Tighten setscrew with a 1/16 hex wrench. DO NOT install vandal resistant plug at this time. MODELS 110/111, 113, 115, 116 & 117 Slide spud coupling, nylon slip gasket, rubber gasket and spud flange over vacuum breaker tube. VACUUM BREAKER TUBE ELBOW FLUSH CONNECTION SPUD COUPLING NYLON SLIP GASKET RUBBER GASKET SPUD FLANGE MODELS 120 & 122 SPUD COUPLING SPUD FLANGE NYLON SLIP GASKET VACUUM BREAKER Insert Tube into Fixture Spud. RUBBER GASKET MODEL 180 Hand tighten Spud Coupling onto Fixture Spud. VACUUM BREAKER TUBE SPUD COUPLING NYLON SLIP GASKET RUBBER GASKET SPUD FLANGE MODEL 186

134 Spec Seq#: INSTALL FLUSHOMETER AND HANDLE ASSEMBLY NOTE For high efficiency urinal flushometers (0.5, 0.25 and gpf), it is necessary to first insert the flow control component into the tailpiece assembly. See the H1015A flow control kit and separate instructions for details on how to install. D Install the red A-31 Handle Gasket on the Handle Assembly. Insert the ADA Handle Assembly (B-73-A) into the Handle opening in the Flushometer Body. Securely tighten the Handle coupling with a wrench. A B C Lubricate tailpiece O-ring with water. Insert Adjustable Tailpiece into Control Stop. Tighten Tailpiece Coupling by hand. Align Flushometer directly above the Vacuum Breaker Flush Connection by sliding the Flushometer Body IN or OUT as needed. Tighten Vacuum Breaker Coupling by hand. NOTE Maximum adjustment of the Sloan Adjustable Tailpiece is 1/2 (13 mm) IN or OUT from the standard 4-3/4 (121 mm) (centerline of Flushometer to centerline of Control Stop). If roughing-in measurement exceeds 5-1/4 (133 mm), consult factory for longer tailpiece. Align Flushometer Body. Using a wrench, securely tighten couplings in the order given: (1) Tailpiece Coupling, (2) Vacuum Breaker Coupling and (3) Spud Coupling. 4 - FLUSH OUT SUPPLY LINE FLUSHOMETER BODY A-31 GASKET HANDLE COUPLING HANDLE ASSEMBLY VACUUM BREAKER COUPLING 2 VACUUM BREAKER FLUSH CONNECTION C/L FIXTURE C/L SUPPLY G-44 FRICTION RING VACUUM BREAKER REPAIR KIT TAILPIECE COUPLING 1 4-3/4 (121 mm) ±1/2 (13 mm) ADJUSTABLE TAILPIECE SPUD COUPLING 3 O-RING CONTROL STOP A Make sure Control Stop is CLOSED and remove Flushometer Outer Cover. C Reinstall Outside and Inside Cover wrench tight. Open Control Stop to flush supply line. Close Control Stop and remove Outside and Inside Cover. B Remove Inside Cover and lift out Inside Parts Assembly. D Reinstall Inside Parts Assembly, Inside Cover and Outside Cover wrench tight. 5 - ADJUST CONTROL STOP AND INSTALL PLUG A B C Open control stop COUNTERCLOCKWISE one FULL turn from closed position. Activate flushometer. Adjust control stop after each flush until the rate of flow delivered properly cleanses the fixture.!!! IMPORTANT!!! Sloan s flushometers are engineered for quiet operation. Excessive water flow creates noise, while too little water flow may not satisfy the needs of the fixture. Proper adjustment is made when the plumbing fixture is cleansed after each flush without splashing water out from the lip AND a quiet flushing cycle is achieved. Never open Control Stop to where the flow from the valve exceeds the flow capability of the fixture. In the event of a valve failure, the fixture must be able to accommodate a continuous flow from the valve. D Install plug into the control stop by pressing into bonnet. BAK CHEK CONTROL STOP H-700 SERIES STOP BONNET PLUG 4

135 Spec Seq#: 12 CARE AND CLEANING DO NOT USE abrasive or chemical cleaners (including chlorine bleach) to clean Flushometers that may dull the luster and attack the chrome or special decorative finishes. Use ONLY mild soap and water, then wipe dry with clean cloth or towel. While cleaning the bathroom tile, protect the Flushometer from any splattering of cleaner. Acids and cleaning fluids will discolor or remove chrome plating. TROUBLESHOOTING GUIDE I. Flushometer does not function (no flush). A. Control stop or main valve is closed. Open control stop or main valve. B. Handle assembly is damaged. Replace handle (B-32-A or B-73-A) or install handle repair kit (B-50-A). C. Relief valve is damaged. Replace inside parts kit. 2. Volume of water is not sufficient to siphon fixture. A. Control stop is not open wide enough. Adjust control stop for desired delivery of water volume. B. Urinal flushometer parts inside a closet flushometer. Replace inside urinal parts with proper closet flushometer parts. C. Low consumption flushometer installed on a non-low consumption fixture. Replace A-41-A inside parts kit with A-38-A water saver kit. D. Water saver kit installed in old, non-water saver bowl. Position refill head A-170 so that SIDE 1 is in the UP position. E. Inadequate volume or pressure at supply. If no gauges are available to properly measure supply pressure or volume of water at the flushometer, then remove the relief valve from the inside parts kit, reassemble the flushometer and open the control stop. If the fixture siphons, more water volume is required. If a 3.5 gpf inside parts kit is installed in the flushometer, then first flip the refill head (under the diaphragm) to obtain a 4.5 gpf volume. If this volume is still inadequate, remove the flow ring from the guide to obtain a 6.5 gpf kit. If additional flow is still required, try a low pressure guide kit A-175-A (# ). IMPORTANT LAWS AND REGULATIONS PROHIBIT THE USE OF HIGHER FLUSHING VOLUMES THAN LISTED ON FIXTURE OR FLUSHOMETER. If fixture does not siphon or if a low consumption fixture is installed, or if the above steps do not prove satisfactory, steps must be taken to increase the pressure and/or supply. 3. Flushometer closes off immediately. A. Damaged diaphragm. Replace inside parts kit to correct problem. B. Enlarged by-pass orifice from corrosion or damage. Install inside parts kit to correct problem and update flushometer. 4. Length of flush is too short (short flush). A. Diaphragm assembly and guide assembly are not hand-tight. Screw the two assemblies hand-tight. B. Enlarged by-pass orifice from corrosion or damage. Install NEW Inside parts kit to correct problem and update flushometer. C. A-19-AU (Black) urinal relief valve in closet flushometer. Replace relief valve with A-19-AC (White) closet relief valve. D. A-41-A low consumption kit installed in non-low consumption fixture. Replace with proper Inside Parts Kit. E. Handle assembly is damaged. Replace handle (B-32-A or B-73-A) or install handle repair kit (B-50-A). 5. Length of flush is too long (long flushing) or fails to close off. A. Relief valve (A-19-A) is not seating properly or by-pass orifice is clogged because of foreign material, or by-pass orifice is closed by an invisible gelatinous film from over-treated water. Disassemble the working parts and wash thoroughly. NOTE: SIZE OF THE ORIFICE IN THE BY-PASS IS OF UTMOST IMPORTANCE FOR THE PROPER METERING OF WATER INTO THE UPPER CHAMBER OF THE FLUSHOMETER. DO NOT ENLARGE OR DAMAGE THIS ORIFICE. REPLACE INSIDE KIT IF CLEANING DOES NOT CORRECT PROBLEM. B. Line pressure has dropped and is not sufficient to force Relief Valve to seat. Shut off all control stops until pressure has been restored, then open them again. C. A-19-AC (White) closet Relief Valve has been used in a 1 or 1½ gpf Urinal. Replace with A-19-AU (Black) Relief Valve. D. Inside cover is cracked or damaged. Replace the Inside Cover (A-71). 6. Chattering noise is heard during flush. A. Inside Cover is damaged. Replace Inside Cover (A-71). B. A-156-A Segment diaphragm has been installed upside-down. Reposition the Segment diaphragm properly (see markings on the Diaphragm). 7. Handle Leaks. A. B-39 Handle Seal is worn or damaged. Install new B-39 Seal. NOTE: The B-39 Seal will easily slide onto the B-40 Bushing when wet. B. Handle gasket has been omitted. Install Handle gasket (A-31) or Sloan handle repair kit (B-50-A). C. Valve handle bushing is worn. Replace handle repair kit (B-50-A). When further assistance is required, please contact Sloan Technical Support at: SLOAN-14 ( ) or visit us online at:

136 Spec Seq#: 12 PARTS LIST 8 Item Part Description No. No. 1 2B 7 H-700 SERIES STOP 3B 3A 1 Valve Assembly 2A B-73-A ADA Compliant Handle Assembly 2B A-31 Handle Gasket 3A H-790-A Bak-Chek Control Stop 3B H-528 Control Stop Bonnet Plug 4A V-500-AA 1½ (38 mm) x 9 (229 mm) Vacuum Breaker Assembly 4B V-500-AA 1¼ (32 mm) x 9 (229 mm) Vacuum Breaker Assembly 4C V-500-AA ¾ (19 mm) x 9 (229 mm) Vacuum Breaker Assembly 4D V-500-A Vacuum Breaker Assembly 5 F-109 1½ (38 mm) Elbow Flush Connection 6A F-56-A 1½ (38 mm) Spud Coupling Assembly 6B F-57-A 1¼ (32 mm) Spud Coupling Assembly 6C F-58-A ¾ (19 mm) Spud Coupling Assembly 7 F-7 Supply Flange (Supplied when Valve is Not Ordered with Sweat Solder Kit) 8 H-633-AA 1 (25 mm) Sweat Solder Kit and Cast Wall Flange with Setscrew H-636-AA ¾ (19 mm) Sweat Solder Kit and Cast Wall Flange with Setscrew A Part number varies with valve model variation; consult factory Length varies with valve model variation; consult factory 4A 4D 5 6A 4B 4C 6A 6B 6C NOTE: The information contained in this document is subject to change without notice. SLOAN SEYMOUR AVENUE FRANKLIN PARK, IL Ph: or Fax: or SLOAN VALVE COMPANY Code No: Rev. 2 (04/14)

137 Spec Seq#: 12 F L U S H O M E T E R S Regal Flushometer Maintenance Guide COVER STOP COUPLING BODY HANDLE COUPLING CONTROL STOP HANDLE ASSEMBLY FLUSH CONNECTION (VACUUM BREAKER) SPUD COUPLING TAILPIECE OUTLET COUPLING SPUD FLANGE SUPPLY FLANGE The Repair Kits and Parts listed on this page are designed to service all Sloan Diaphragm type Flushometers, including those manufactured for Low Consumption (LC) usage. Each item has been identified by a Part Number and a corresponding Code Number. To expedite your replacement requirements, order by Code Number. PARTS LIST R-10 CP Cover A-71 Inside Cover 3A A-19-AC Relief Valve, White (Closet)- 12 per pkg. 3B A-19-AU Relief Valve, Black (Urinal)- 12 per pkg. 3C A-19-ALC Relief Valve, Green (Closet/Urinal-LC)- 12 per pkg. 3D A-19-AL Relief Valve, Blue (9 Liter Closet)- 12 per pkg A-15-A Disc - for all Inside Parts Kits - 12 per pkg A-156-A Diaphragm - for all Inside Parts Kits - 12 per pkg. 6A A-163-A Guide Assem. 4.5 gpf/17.0 Lpf Closet & 1.5 gpf/5.7 Lpf Urinal -12 per pkg. 6B A-152-A Guide Assem. 3.5 gpf/13.2 Lpf Closet - 12 per pkg. 6C A-151-A Guide Assem. 1.6 gpf/6.0 Lpf LC Closet - 12 per pkg. 6D A-155-A Guide Assem. 1.0 gpf/3.8 Lpf LC Urinal - 12 per pkg. 6E A-157-A Guide Assem. 0.5 gpf/1.9 Lpf Urinal - 12 per pkg. 7. SEE INSIDE PARTS KITS CHART ON THE REVERSE SIDE B-39 Seal - 12 per pkg B-32-A CP Handle Assem. - 6 per pkg B-73 CP Handicap Handle Assem. (A.D.A. Compliant) A-6 CP Handle Coupling B-7-A CP Socket Assem B-32 CP Handle Grip - 12 per pkg B-74-A CP Handicap Handle Grip (A.D.A. Compliant) B-50-A Handle Repair Kit - 6 per pkg A-31 Handle Gasket - 48 per pkg F-54-A 3/4'' CP Spud Coupling Assem F-55-A 11/4'' CP Spud Coupling Assem F-56-A 11/2'' CP Spud Coupling Assem V-551-A Vacuum Breaker Repair Kit V-500-AA 3/4'' x 9'' CP Vacuum Breaker - 6 per pkg V-500-AA 11/4'' x 9'' CP Vacuum Breaker - 6 per pkg V-500-AA 11/2'' x 9'' CP Vacuum Breaker - 6 per pkg H-550 CP Stop Coupling H-551-A CP Adjustable Tailpiece 21/16'' long H-553 O-Ring - 24 per pkg. ABBREVIATIONS: Assem: = Assembly CP = Chrome Plated gpf = gallons per flush Lpf = Liters per flush LC = Low Consumption pkg = package w/ = with H-740-A 1'' Screwdriver Bak-Chek Stop CP - complete H-740-A 3/4'' Screwdriver Bak-Chek Stop CP - complete H-541-A 1'' Control Stop Repair Kit * H-543-A 3/4'' Control Stop Repair Kit ** H-639 CP Bonnet * H-538 CP Bonnet ** H-37 CP Cap - 6 per pkg J-2/J-7 Bumper Assem. - 6 per pkg. * for use with H-740 1'' & 3/4'' and H-540-A 1'' Screwdriver Bak-Chek Control Stops ** for use with H-540-A 3/4'' Screwdriver Bak-Chek Control Stops MASTER FLUSHOMETER REBUILDING KITS Includes Items & 20 CODE NO. KIT NO. DESCRIPTION R-1001-A Rebuild Kit (4.5 gpf/17.0 Lpf) Closet/Service Sink R-1002-A Rebuild Kit (1.5 gpf/5.7 Lpf) Urinal R-1003-A Rebuild Kit (3.5 gpf/13.2 Lpf) Closet R-1004-A Rebuild Kit (1.6 gpf/6.0 Lpf) Closet R-1005-A Rebuild Kit (1.0 gpf/3.8 Lpf) LC Urinal R-1011-A Rebuild Kit (0.5 gpf/1.9 Lpf) Urinal R-1012-A Rebuild Kit (2.4 gpf/9.0 Lpf) Closet WASHER SET A-156-AA Washer Set - Includes: 4, 5, 8 & 14 The information contained in this document is subject to change without notice. SLOAN VALVE COMPANY SEYMOUR AVENUE FRANKLIN PARK, IL Phone: VALVE-9 or Fax: or Copyright 2003 Sloan Valve Company Printed in the U.S.A. Made in the U.S.A. REGAL M.G. Rev. 2a (05/03) Code No

138 Spec Seq#: 12 Troubleshooting and Maintaining the Sloan Regal Flushometer 1. PROBLEM: Flushometer does not function. CAUSE: (a.) Control Stop or Main Valve is closed. (b.) Handle Assembly is worn. (c.) Relief Valve is worn. SOLUTION: (a.) Open Control Stop or Main Valve. (b.) Install Sloan Handle Repair Kit (B-50-A) or replace handle. (c.) Replace Inside Parts Kit. 2. PROBLEM: Insufficient volume of water to adequately siphon fixture. CAUSE: (a.) Control Stop not open enough. (b.) Urinal Flushometer Parts inside a Closet Flushometer. (c.) Low Consumption Flushometer installed on a non-low Consumption fixture. (d.) Water Saver Kit installed in old, non-water Saver bowl. (e.) Inadequate volume or pressure at supply. SOLUTION: (a.) Adjust Control Stop for desired delivery of water. (b.) Replace Inside Urinal Parts with proper Closet Flushometer Parts. (c.) Replace A-41-A Inside Parts Kit with A-38-A Water Saver Kit. (d.) Position Refill Head A-170 so that SIDE 1 is in the UP Position. (e.) If no gauges are available to properly measure supply pressure or volume of water at the Flushometer, then remove the Relief Valve from the Inside Parts Kit, reassemble the Flushometer and open the Control Stop. If the fixture siphons, more water volume is required. If a 3.5 gpf Inside Parts Kit is installed in the Flushometer, then first flip the Refill Head (under the Diaphragm) to obtain a 4.5 gpf volume. If this volume is still inadequate, remove the Flow Ring from the Guide to obtain a 6.5 gpf Kit. If additional flow is still required, try a Low Pressure Guide Kit A-175-A (# ). IMPORTANT: Laws and Regulations requiring Low Consumption Fixtures (1.6 gpf Water Closets and 1.0 gpf Urinals) prohibit the use of higher flushing volumes. If fixture does not siphon or if a Low Consumption fixture is installed, or if the above steps do not prove satisfactory, steps must be taken to increase the pressure and/or supply. 3. PROBLEM: Flushometer closes off immediately. CAUSE: (a.) Ruptured or damaged Diaphragm. (b.) Enlarged By-Pass orifice from corrosion or damage. SOLUTION: Install Inside Parts Kit to correct above problems and update Flushometer. 4. PROBLEM: Length of flush is too short (Short Flushing). CAUSE: (a.) Diaphragm Assembly and Guide Assembly are not handtight. (b.) Enlarged By-pass orifice from corrosion or damage. (c.) A-19-AU (Black) Urinal Relief Valve in Closet Flushometer. (d.) A-41-A Low Consumption Kit installed in non-low Consumption fixture. (e.) Handle Assembly is worn. SOLUTION: (a.) Screw the two assemblies hand-tight. (b.) Install NEW Inside Parts Kit to correct problem and update Flushometer. (c.) Replace Relief Valve with A-19-AC (White) Closet Relief Valve. (d.) Replace with proper Inside Parts Kit. (e.) Install Handle Repair Kit B-50-A or replace the Handle. 5. PROBLEM: Length of flush is too long (Long Flushing) or fails to close off. CAUSE: (a.) Relief Valve (A-19-A) is not seating properly or Bypass orifice is clogged because of foreign material, or Bypass orifice is closed by an invisible gelatinous film from over-treated water. (b.) Line pressure has dropped and is not sufficient to force Relief Valve to seat. (c.) A-19-AC (White) Closet Relief Valve has been used in a 1 or 11/2 gpf Urinal. (d.) Inside Cover is cracked or damaged. SOLUTION: (a.) Disassemble the working parts and wash thoroughly. NOTE: SIZE OF ORIFICE IN THE BY-PASS IS OF UTMOST IMPORTANCE FOR PROPER METERING OF WATER INTO THE UPPER CHAMBER OF THE FLUSHOMETER. DO NOT ENLARGE OR DAMAGE THIS ORIFICE. REPLACE INSIDE KIT IF CLEANING DOES NOT CORRECT PROBLEM. (b.) Shut off all control stops until pressure has been restored, then open them again. (c.) Replace with A-19-AU (Black) Relief Valve. (d.) Replace the Inside Cover (A-71). 6. PROBLEM: Chattering noise in Flushometer. CAUSE: (a.) The A-156-A Segment Diaphragm has been installed upsidedown. (b.) The Inside Cover has been distorted from wear, freezing or abuse. SOLUTION: (a.) Replace the Segment Diaphragm to the proper position as instructed by markings on the Diaphragm. (b.) Replace Inside Cover. 7. PROBLEM: Leaking at Handle Assembly. CAUSE: (a.) The B-39 Seal is worn or deteriorated. (b.) Handle gasket has been omitted. (c.) Valve Handle Bushing is worn. SOLUTION: (a.) Install new B-39 Seal. NOTE: The B-39 Seal will easily slide right onto the B-40 Bushing if it is wet. (b.) Install A-31 Handle Gasket or Sloan Handle Repair Kit (B-50-A). (c.) Install Sloan Handle Repair Kit (B-50-A). CARE AND CLEANING INSTRUCTIONS DO NOT use abrasive or chemical cleaners to clean Flushometers, they may dull the luster and attack the chrome or special decorative finishes. Use ONLY soap and water, then wipe dry with a clean towel or cloth. While cleaning the bathroom tile, the Flushometer should be protected from any splattering of cleaner. Acids and cleaning fluids can discolor or remove chrome plating. If further assistance is required, please contact the Sloan Valve Company Installation Engineering Dept. at SLOAN SLOAN VALVE COMPANY SEYMOUR AVENUE FRANKLIN PARK, IL Phone: VALVE-9 or Fax: or Copyright 2003 Sloan Valve Company Printed in the U.S.A. Made in the U.S.A. REGAL M.G. Rev. 2a (05/03) Code No

139 RECIRCULATION PUMP Spec Seq#: 13

140 Spec Seq#: 14 GRUNDFOS INSTRUCTIONS UP Series circulators US Installation and operating instructions CONTENTS Shipment Inspection...2 Pre-Installation Checklist...2 Installation...3 Electrical...4 Start-Up...5 Operation...6 Failure to Operate...6 Warranty

141 Spec Seq#: 14 Shipment Inspection Examine the components carefully to make sure no damage has occurred to the pump during shipment. Care should be taken to ensure the pump is NOT dropped or mishandled; dropping will damage the pump. Pre-Installation Checklist Before beginning installation procedures, the following checks should be made. They are all important for proper installation of the circulator pump. 1. Uses: Model UP(S)15, 26, 43 and 50 series pumps are generally designed to circulate water from 32 deg F to 230 deg F up to a maximum pressure of 150 psi. Some models have temperature limitations which are shown in Table 2A below. If required, a 50% by volume solution of ethylene or propylene glycol and water can be used, however, a decrease in pump performance may result due to an increase in the viscosity of the solution. Check with manufacturer for information regarding suitability of pumping other fluids. Closed Systems: Model UP(S)15, 26, 43 and 50 series pumps with cast iron pump housings are designed to pump water compatible with their cast iron construction. They are recommended for use in closed hydronic systems. (i.e. airless, non-potable water). Open Systems: Model UP(S)15, 26, 43 and 50 series pumps with stainless steel or bronze pump housings are designed to pump water compatible with their construction and can be used in both open and closed systems Maximum Water Temperature: The maximum allowable water temperature is determined by the ambient or surrounding air temperature as shown in Table 2A. Table 2A Maximum Water Temperature Ambient ( F) Water All UP* ( F) *Exceptions below: UPS UP15-100F ( F) UP26-120U ( F) UP ( F)

142 Spec Seq#: Inlet Pressure Requirements The amount of pressure required at the inlet of the pump is a function of the temperature of the water as shown in Table 2B. Table 2B - Minimum Required Inlet Pressure Fluid Temp 230 (110 C) 190 (88 C) 140 (60 C) Feet of Water 36 ft. (1.10m) 9 ft (2.8m) 3 ft (0.9m) Inlet Pressure 15.6 psi 4.0 psi 1.3 psi In a pressurized system, the required inlet pressure is the minimum allowable system pressure. In a system open to the atmosphere, the required inlet pressure is the minimum distance the pump must be located below the lowest possible water level of the water source (tank, pool, etc.). Installation Position of terminal box: Proper installation of the pump will have the terminal box located to one side of the pump or the other, with the conduit entry down. See Figure 3A. Figure 3A Recommended Terminal Box Orientation If the terminal box position needs to be changed, it is best to do so before installation. However, if the pump is already installed, ensure that the electrical supply is turned off and close the isolation valves before removing the Allen screws. To change terminal box position: 1. Remove the four (4) Allen screws (4 or 5mm wrench) while supporting the stator (motor). 2. Carefully separate the stator from the pump chamber and rotate it to the correct terminal box orientation. 3. Replace the Allen screws and tighten diagonally and evenly (7 ft.-lb. torque). 4. Check that the impeller turns freely. If the impeller does not turn easily, repeat the disassembly/ reassembly process. 3

143 Spec Seq#: 14 Pump Mounting: For Indoor Use Arrows on the side or bottom of the pump chamber indicate direction of flow through the pump. GRUNDFOS circulators can be installed in both vertical and horizontal lines. The pump must be installed with the motor shaft positioned horizontally. Under no circumstances should the pump be installed with the shaft vertical or where the shaft falls below the horizontal plane. See Figure 3B. Figure 3B Acceptable Unacceptable It is recommend that isolation valves be installed on each side of the pump. If possible, do not install elbows, branch tees, and similar fittings just before or after the pump. Provide support to the pump or adjacent plumbing to reduce thermal and mechanical stress on the pump Installation Requirements 1. Thoroughly clean and flush the system prior to pump installation. 2. Do not install the pump at the lowest point of the system where dirt and sediment naturally collect. 3. Install an air vent at the high point(s) of the system to remove accumulated air. 4. Ensure that water does not enter the terminal box during the installation process. 5. (Open System) Install the pump in the supply line; the suction side of the pump should be flooded with water. Ensure that the static head requirement from Table 2B is achieved. 6. (Closed System) Install a safety relief valve to protect against temperature and pressure build-up. 7. If there are excessive suspended particles in the water, it is recommended that a strainer and/or filter be installed and cleaned regularly. 8. DO NOT START THE PUMP UNTIL THE SYSTEM HAS BEEN FILLED. CHECK VALVE REMOVAL: 1. Use needle nose pliers to remove check valve from pump housing. 2. Check to make sure no part of the valve remains in the pump housing. 3. Apply enclosed round "Check Valve Removed" label over the Check mark symbol located on the name plate of the pump. 4

144 Spec Seq#: 14 Electrical All electrical work should be performed by a qualified electrician in accordance with the latest edition of the National Electrical Code, local codes and regulations. Warning: The safe operation of this pump requires that it be grounded in accordance with the National Electrical Code and local governing codes or regulations. The ground wires should be copper conductor of at least the size of the circuit conductor supplying power to the pump. Minimum ground wire size is 14 AWG. Connect the ground wire to the grounding point in the terminal box and then to an acceptable ground. Do not ground to a gas supply line. The proper operating voltage and other electrical information can be found on the nameplate attached to the top of the motor. Depending on pump model, the motor has either built-in, automatic resetting thermal protection or is impedance protected and in either case does not require additional external protection. The temperature of the windings will never exceed allowable limits, even if the rotor is locked Wire sizes should be based on the ampacity (current carrying properties of a conductor) as required by the latest edition of the National Electrical Code or local regulations. Both the power and grounding wires must be suitable for at least 194 F (90 C). For all 115V and 230V models: Connect the white/white electrical leads from the circulator to the incoming power leads with wire nuts or other approved connectors. Attach incoming grounding wire to either of the green grounding screws. Figure 1 White Green Grounding Screws Ground Capacitor Wiring diagram for all 115V and 230V single speed pumps. 5

145 Spec Seq#: 14 Wire the hot lead to terminal "L," neutral wire to terminal "N," and ground to the grounding terminal. For 230 volt pumps, the two hot leads should be to "L" and "N" and the ground to the grounding terminal. Figure 2 CAPACITOR Wiring diagram for 115V and 230V multi-speed pumps Green Ground Neutral Line *UP(S) 15 capacitor wire position 4 & 8 *UP(S) 26/43/50 capacitor wire position 2 & 4 Start-Up Do not use the pump to vent the system. Do not start the pump before filling the system. Never operate the pump dry. Operation GRUNDFOS domestic circulating pumps, installed properly and sized for correct performance, will operate quietly and efficiently and provide years of service. Under no circumstances should the pump be operated without water circulation or without the minimum required inlet pressure for prolonged periods of time. This could result in motor and pump damage.ups model pumps are multispeed, and the speed can be changed by a speed selector switch located on the front of the terminal box. UP models are single speed. Failure to Operate When UPS and UPS 26/43 pumps are first started, the shaft may rotate slowly until water has fully penetrated the bearings. If the pump does not run, the shaft can be rotated manually. To accomplish this, switch off the electrical supply, and close the isolation valves on each side of the pump. Remove the indicator plug in the middle of the nameplate. Insert a small flat blade screwdriver into the end of the shaft, and gently turn until the shaft moves freely. Replace and tighten the plug. Open the isolation valves and wait 2 to 3 minutes for the system pressure to equalize before starting the pump. NOTE: After a long shut down multi-speed pumps should be started on speed 3 and then adjusted to the regular setting. The UPS has automatic function to assist in restart. *IMPORTANT NOTE*: For figure 1, the cap plug has not been installed. This pump is supplied with two wiring ports. To ensure safe operation of your installation, the enclosed cap plug MUST be inserted into the unused port

146 Spec Seq#: 14 Limited Warranty UPS15, 26, 43 circulator pumps manufactured by GRUNDFOS PUMPS CORPORATION (GRUNDFOS) are warranted to the original user only to be free of defects in material and workmanship for a period of 36 months from date of manufacture. GRUNDFOS' liability under this warranty shall be limited to repairing or replacing at GRUNDFOS' option, without charge, F.O.B. GRUNDFOS' factory or authorized service station, any UPS15, 26, 43 or UP15-42F circulator pump. GRUNDFOS will not be liable for any costs of removal, installation, transportation, or any other charges which may arise in connection with a warranty claim. All other UP and UPS small circulators manufactured by GRUNDFOS PUMPS CORPORATION (GRUNDFOS) are warranted to the original user only to be free of defects in material and workmanship for a period of 24 months from date of installation, but not more than 30 months from date of manufacture. GRUNDFOS' liability under this warranty shall be limited to repairing or replacing at GRUNDFOS' option, without charge, F.O.B. GRUNDFOS' factory or authorized service station, any product of GRUNDFOS manufacture. GRUNDFOS will not be liable for any costs of removal, installation, transportation, or any other charges which may arise in connection with a warranty claim. Products which are sold but not manufactured by GRUNDFOS are subject to the warranty provided by the manufacturer of said products and not by GRUNDFOS' warranty GRUNDFOS will not be liable for damage or wear to products caused by abnormal operating conditions, accident, abuse, misuse, unauthorized alteration or repair, or if the product was not installed in accordance with GRUNDFOS' printed installation and operation instructions. To obtain service under this warranty, the defective product must be returned to the distributor or dealer of GRUNDFOS products from which it was purchased together with proof of purchase and installation date, failure date, and supporting installation data. Unless otherwise provided, the distributor or dealer will contact the GRUNDFOS factory or authorized service station for instructions. Any defective product to be returned to the factory or service station must be sent freight prepaid; documentation supporting the warranty claim and/or a Return Authorization must be included if so instructed. GRUNDFOS WILL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSSES, OR EXPENSES ARISING FROM INSTALLATION, USE, OR ANY OTHER CAUSES. THERE ARE NO EXPRESS OR IMPLIED WARRANTIES, INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH EXTEND BEYOND THOSE WARRANTIES DESCRIBED OR REFERRED TO ABOVE. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages and some jurisdictions do not allow limitations on how long implied warranties may last. Therefore, the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction. 7

147 Spec Seq#: Grundfos Pumps Corporation W. 118th Terrace Olathe, Kansas Telephone: (913) Fax: (913) L-UP-TL Repl PRINTED IN USA Bombas Grundfos de Mexico, S.A. de C.V. Boulevard TLC #15, Parque Industrial Stiva Aeropuerto C.P Apodaca, N.L. Mexico Telephone: Fax: Grundfos Canada, Inc Brighton Rd. Oakville, Ontario L6H 6C9 Telephone: (905) Fax: (905)

148 Spec Seq#: 15 GRUNDFOS INSTRUCTIONS Installation and Operation Maintenance-free Timer and Thermostatic Control Accessories New Style Terminal Box Single Speed UP-15 Only with Date Code 0528 or higher.

149 Spec Seq#: Application Grundfos timer and thermostatic control accessories are designed only for use with specified Grundfos Series UP circulators installed in indoor hot water service systems. Applicable Series UP models include all single speed UP 10-15, 1-phase, 115 volt, 60 hertz pumps with date codes of 0528 and higher. The timer control is designed to turn the circulator on and off at preset times, allowing the user to select operation of the circulator during high use periods of the day. The thermostatic control automatically turns the circulator off when the temperature in the hot water line exceeds approximately 130 F (as the case of periods with no demand) and back on when the temperature falls below approximately 110 F (as in the case of periods with high demand). When the timer and thermostatic controls are installed together, in series, the circulator operates ONLY at the preset clock times specified by the user AND ONLY when the temperature conditions of the thermostat are met. That is, if either the timer control or the thermostatic control switch is open (off), the circulator will not operate. 2. Technical Data TIMER CONTROL Supply Voltage: VAC, 60 hertz Contact Rating:16 amps Ambient Temperature:-4 F to 175 F Shortest Switching Interval:15 minute increment Switch Modes: Timer, ON Override, OFF Override Protection: Clear plastic cover for dust and moisture protection of the clock face THERMOSTATIC CONTROL Supply Voltage: VAC, 60 hertz Contact Rating (resistive):5.8 amps Type:Surface sensing, snap acting bimetallic disc Enclosure:Environmentally sealed Switch Modes: Low Temp Model 105 ± 5 F (40 ± 2 C) pump switches OFF 85 ± 6 F (29 ± 3 C) pump switches ON High Temp Model 115 ± 5 F (46 ± 2 C) pump switches OFF 105 ± 5 F (40 ± 2 C) pump switches ON 42243

150 Spec Seq#: 15 Contact Position: Mounting: Normally closed (1/2 ) Clip-on type for 5/8 O.D. system piping size (i.e., 1/2 I.D. copper tubing or 3/8 steel pipe) (3/4 ) Clip-on type for 7/8 O.D. system piping size (i.e., 3/4 I.D. copper tubing or 1/2 steel pipe) May be mounted on either the inlet or outlet piping of the circulator. 3. Installing the Timer Control POSITION OF PUMP MOTOR SHAFT AND TERMINAL BOX All Series UP circulators MUST be installed with the motor shaft in the horizontal position. The pump terminal box MUST be located on top or to either side of the motor housing X CAUTION: Do not locate the terminal box below the motor housing. To change the terminal box position: 1. Remove the (4) allen screws while supporting the motor. 2. Carefully separate the motor from the pump chamber and rotate it to the desired terminal box position. 3. Replace the allen screws and tighten diagonally and evenly (7 ft-lb torque). 4. Check that the motor shaft turns freely. Remove the large screw in the middle of the name plate, insert a small flat blade screwdriver into the slot at the end of the shaft, and turn gently. (Note:Not applicable to UP15-42F & UPS15-58FC models.) 5. If the shaft does not turn freely, repeat the disassembly/reassembly process. NOTE: If the pump is installed in a system, disconnect the power supply and either drain the system of liquid or close the isolation valves on either side of the circulator before removing the motor housing.

151 Spec Seq#: 15 INSTALLATION PROCEDURE The timer control accessory is electrically connected and mounted to the circulator terminal box. Install as follows: 1. Remove the retaining screws in the existing terminal box cover and remove the cover. The timer control unit replaces this cover. 2. See 5. Electrical Hookup, for specific wiring instructions for hookup as an individual component or in series with the thermostatic control. 3. After wiring is completed and checked, install the timer control unit onto the terminal box bracket and reinsert the terminal box screws. Be careful not to bind or leave exposed any terminal box wires Installing the Thermostatic Control INSTALLATION PROCEDURE 1. The thermostatic control is a surface temperature sensing device that must be in contact with the system piping to operate properly. Separate models include clip-on mounts for 3/4 (7/8 O.D.) and 1/2 (5/8 O.D.) copper tubing. These models are also suitablefor use with 12 and 3/8 schedule 40 steel pipe, respectively. 2. See 5 Electrical Hook-up, for specific wiring instructions for hook-up as an individual component or in series with the timer control. 3. Use a common strain relief for the power and aquastat cords. 5. Electrical Hook-up All electrical work should be performed by a qualified electrician in accordance with the latest edition of the National ElectricCode and local codes and regulations. Verify the electrical supply to be certain the voltage, phase and frequency match that of the circulator and accessory components. WARNING: Terminal Block Connections 1-8; Factory connections only, NO field wiring required

152 Spec Seq#: 15 Aquastat Terminal Box Green Black White L Timer 2 1 M 3 4 T/S Pump 2 1 M N L N Capacitor Black Yellow Blue White White Blue 1 2 Blue 3 4 Yellow 5 WIRING DIAGRAM FOR TIMER AND AQUASTAT Timer Setting and Operating the Timer Control and Starting the Pump PROGRAMMING RING TIMING ARROW MANUAL SWITCH PROGRAMMING TABS

153 S.A.E. co. Southern Atlantic Electric Company, Inc. EUROPEAN STREET - SAN MARCO LIGHTING FIXTURE SUBMITTALS QTY MANUFACTURER MODEL NUMBER DESCRIPTION SEAGULL LIGHTING DINING PENDANT SEAGULL LIGHTING ENTRANCE WALL SCONCE SEAGULL LIGHTING MEN'S ROOM VANITY SEAGULL LIGHTING WOMEN'S ROOM VANITY JUNO P47-BLZ COMMUNITY TABLE MINI PENDANT JUNO R600L-WHITE COMMUNITY TABLE & BAR FLOOD JUNO TU-12FT 2-ClRCUIT COMMUNITY TABLE TRACK JUNO T-8FT 1-CIRCUIT BAR TRACK LITHONIA LIGHTING GT3L MV TROFFER FIXTURE LITHONIA LIGHTING L7XLED T24 RECESSED HOUSING LITHONIA LIGHTING 6BPMW HLLED DOWNLIGHTING TRIM Columbia Park Drive East Jacksonville, FL (904) Fax (904) EC

154 Vist our web site at page 1 of 1 Sea Gull lighting. life 1II/IIlIilla/cd I Si ncr : Two Light Pendant Dimensions: Diameter: Height: Weight: B.9 Ibs. 123/4" 8 1/2" Overall Height 53 1/2" Wire: 120" (color/clear Silver) Mounting Proc.: Center Lock-Up Connection: Mounted To Box Bulbs: 2 - Medium A19 75w Max, 120v - Not included Features: Easily converts to LED with optional replacement lamps Sloped ceiling mounting hardware included Meets Title 24 energy efficiency standards Title 24 compliant if used with Joint Appendix (JAB) approved light bulbs listed in the California Energy Commission Appliance database. Material List: Collection: Pratt Street Prismatic Three 12" stems and one 6" stem included for adjustable mounting heights. UPC #' Finish: Brushed Nickel (962) 3 12" Stem - Steel - Brushed Nickel 1 Body - Steel - Brushed Nickel 1 6" Stem - Steel - Brushed Nickel Safety Listing: Safety Listed for Damp Locations Safety Listed for Damp Locations Instruction Sheets: Trilingual (E nglish, Spanish, and French) (990P65061-PST) Shade I Glass I Diffuser Details: Part Material Finish Quantity Item Number length Shade Glass Clear Ribbed 1 Diffuser Glass Clear Textured 1 Width Height Diameter Fitter Shade Top Shade Top Shade Top Diameter length Width Diameter 81/2 123/4 1/4 11 3/4 Backplate I Canopy Details:..,. Type Height I length Width Depth Canopy 1 1/4 Shipping Information: Package Type Quantity UPC Individual ( \ NJ Pallet J>. J-T 30 NV Pallet 30 Diameter Outlet Box Up Outlet Box Down 51/2 Length Width Height Cube Weight Frt. Class UPS Ship Yes No No Sea Gu. Lighting reserves the right 10 revise the design of components of any product due to parts availability or change in safety listing standards without assuming any obligation or ~ability to modify any products previously manufactured and without notice. Th;, literature depicts a product design that is the sole and exckjsive property of Sea Gull Lighting. In compliance with U,S copyright and palent requirements. notification is hereby presented in this form lhat this lileralure. or the product it depicts. ;, nol to be copied, altered or used in any manner without Ihe e)(press written coosenl of, or conlrary to the best interests 01 Sea Gu. Lighting i c. Y' A Generalion Brands Company.

155 Vist our web site at page 1 of 1 Sea Gull Lighiing. c --~-~ fiji' liililiiillllfl'd I Since : One Light Wall Sconce Dimensions: Width: Height: Weight: 5.1 Ibs. 11 " 105/8" Extends: 12 l /B" Wire : 6" (color/blacklwhite) Mounting Proc.: Wall! Bath Connection: Mounted To Box Bulbs: 1 - Medium A19 60w Max. 120v - Not included Features: Easily converts to LED with optional replacernentlamps Meets Title 24 energy efficiency standards Title 24 compliant if used with Joint Appendix (JAB) approved light bulbs listed in the California Energy Commission Appliance database. Material List: 1 Body - Steel - Brushed Nickel Collection: Pratt Street Sconces UPC #: Finish: Brushed NiCk~ Safety Listing: Safety Listed for Damp Locations Instruction Sheets: Trilingual (English, Spanish. and French) (990W PST) Shade I Glass I Diffuser Details: P,rt Material Finish Quantity Item Number Glass Glass Clear Prismatic 1 Backplate I Canopy Details: Type Height I Length Width Back Plate Length Depth 1 1/4 Width Height Diameter Fitter Shade Top Shade Top Shade Top Diameter Length Width Diameter Diameter Outlet Box Up Outlet Box Down 5 1/2 5 55/8 Shipping Information: Package Type.... Quantity UPC Individual t J NJ Pallet 54 NV Pallet 45 Length Width Height Cube Weight Frt. Class UPS Ship Ves No No Sea GuM lighting reserves the right to revise the design of components of any product due to parts availability or change in safety lisling standards without assuming any obligation or Wabitity to modify any products previously manufactured and without notice. This literature depicts a product design thai is the sole and Ij~ctusive property of Sea Gull lighting. In compliance with U.S copyright and patent requirements. notificaijon is hereby presented in th is lorm that this titerature. or the product it depicts. is not to be copied. altered or used in any manner wilhoul the e)(press written consent 01. or contrary to the best interests 01 Sea Gul Lighting i,yo A Generation Brands Company.

156 Vis! our web site at page 1 of 1 Sea Gull Lighllng. U!<' /11I1/11;lIatt>d : Six Light Wall I Bath Since 1919 Dimensions: Width : 36" Extends: 2 1/4" Height: 4 1/4" Wire: 6 1/2" Mounting Proc.: Wall I Bath Connection : Mounted To Box " Bulbs: 6 - Medium G25 100w Max. 120v - Not included Features: Fixture may be mounted horizontal or vertical Meets Title 24 energy efficiency standards Title 24 compliant if used with Joint Appendix (JAB) approved light bulbs listed in the California Energy Commission Appliance database. Material List: 1 Body - Steel - Chrome Collection: Center Stage Six Light Chrome Bath Bracket that can be Mounted Horizontal or Vertical. The Bulbs are spaced at 6in apart. Six-bulb bar light fixture with chrome finish. Sockets spaced on 6 M centers. Safety Listing: Safety Listed for Damp Locations Instruction Sheets: Trilingual (English, Spanish, and French) (HC-107FB) UPC #: ~inish : Chrome (05) ----r---->-- Backplate I Canopy Details: Type Back Plate Height I Length Width Depth Diameter Outlet Box Up Outlet Box Down 2 1/8 Shipping Information: Package Type r ofroauct Quantity Individual ( ;-' 1 Master Pack - 6 NJ Pallet 240 NV Pallet 210 UPC Length Width Height Cube Weight Frt. Class UPS Ship Yes Yes No No Sea Gull Lighting reserves the right 10 revise the design of componenls of any prodl.1cl due to parts availability or change in safely listing slandards without assuming any obligation or ~ability 10 modify any products previously manufactured and without notice. This literature depicts a product design thai is the so/e and e~clusive property of Sea Gull lighting. In compliance wi!h U.S copyright and patent requirements, notificatioo is hereby presented in this form that!his literature, or Ihe product it depicts, is not to be copied. altered or used in any manner without the express written consent of, or contrary to!he best interests of Sea Gull l ighting ii-yo A Generatioo Brands Company.

157 Vist our web site at page 1 of 1 Sea Gull lighting. UJi' liiuli/illated I Si nce : Eight Light Wall I Bath Dimensions: Width: 48" Extends: 2 1/4" Height: 4 1/4" Wire : 61/2" Mounting Proc.: Wall I Bath Connection: Mounted To Box Bulbs: B - Medium G25 1QOw Max. 120v - Not included Features: Fixture may be mounted horizontal or vertical Meets Title 24 energy efficiency standards Title 24 compliant if used with Joint Appendix (JAB) approved light bulbs listed in the California Energy Commission Appliance database. Material List: 1 Body - Steel - Chrome Collection: Center Stage Eight Light Chrome Bath Bracket that can be Mounted Horizontal or Vertical. The Bulbs are spaced at 6in apart. Eight-bulb bar light fixture with chrome finish. Sockets spaced on 6" centers. Safety Listing: Safety Listed for Damp Locations Instruction Sheets: Trilingual (English, Spanish, and French) (HC-107FB) UPC#: ~Sh: Chrome (05) - -r-- _.-r- Backplate I Canopy Details: > Type Height I length Width Depth Diameter Outlet Box Up Outlet Box Down Back Plate 21/8 Shipping Information: Package Type r l'roduct1f-..., Quantity UPC length Width Height Cube Weight Frt. Class UPS Ship Individual (, Ves Master Pack I-'-u-uo Ves NJ Pallet No NV Pallet No Sea GuM Lighlillg reserves the right to rellise the design of componellts of any pl"oduct due to parts availability or change in safety listing standards without assuming any obligatioll or fiabili.ty to modify ally products previously manufactured and without nollce. This literature depicts a product design thai is the sole and exclusive property of Sea Gull Lighting. In compliance wilh U.S copynght and patent requirements, notification is hereby presented in this IOfm that this literature, or the product it depicts, is 1101 to be copied. altereef or used in ally manner withoot the express written consent 01, or contrary to the best interests of Sea Gul Lighting "iloy. A Generation Brands Compally.

158 ( ---- D1.10.2G2 DECORATIVE PENDANTS LOW VOLTAGE - LED DPEND SERIES ORDERING INFORMAnON Q,dering hompl. DPEND MP G2 P316 OPEEL7BIN LED12 30K BOCRI SNC SNA Series Moun~ng Adopleo" Type Generation Shade Style (Shope)' Shade Finish' DPENO Juno Decorative "2 Flex 12 Adopter2 102 Generation 21 P136 Medium Cylinde ri' ADR" Amber Drift Pendants MP Single Dome P310 Short Cone Glan" AMI Amber Monopointl P311 Short Cone Melolo AMO Amber Onyx MP3 Triple Disc P312 TaU Cone Glossb AMS Amber Storm MonoDointl P314 Flute Glossb BLZ Blizzard I QJ Quick Jack J P315 Flute Melolo CBLT Cobalt Adapt.~ T12 Troe 12 AdopterS P316 Wrap" CDZ Chocolate Drizzle P318 Teardrop" FRT Frost P322 Small Ellipse o GLAC Glacier P324 Cylind.<, lnf Inferno P326 RLM' LIM l ime P328 Disco MAIZ Maize P38 Dolce OPEEL Orange Peel P45 Toll Dome OPL Opal P47 fargoo I PARCH Parchment P52 Unyx Dome PIST Pistachio P61 Mediu m Flute RAD Radiont Red P68 Toll Teardrop ROUG Rouge P88 Ellipse 5LVR Silver P95 long Cone SUN Sundae TOR Tortoise WHO While O nyx Cordset Length lamp Type CoIo..~ Colo.. Rendering Cordset Finish I 781N! 44 1~ l~~ I~ ~ g W i Cg l L~g tb 78 IN Nominal len th I I LED12 LED, 12V I 27K 2700K IBOCR! BO CRI I I~ 30K 3000K I ISNC a~c;u' ~gu;b~ 1 Sotin Nickel Cordset I ~ng Adopter Finish ala aza SIA SNA WHA Black Adapter Finish Bronze Adapter Finish Sil... ~r AdoniA( fini!i.h Satin Nickel Adooter fini sh I While Adopter Finish Notes; 1 See shade style descriptions on pages 4-7 to determine available shade finishes. 2 Flex 12 IF 12) Mou nting Adapter Type is available in Silver Adapter Finish ISlA) only. 3 Sing le Dome Monopoinl (MP). and Triple Disc Monopoint (MP3) Mounting Adopter Types moy be specified with BZA or SNA Mounting Adopter Finishes only..4 Quick Jock Adapter (QJ) Mounting Adapter Type may be specified with BLA, BZA, SNA, or WHA Mounting Adopter f inishes only. 5 Troe 12 Adopter ft 12) Mounting Adopter Type may be specified with BLA, SLA or WHA Mounting Adopter Finishes only. 5 P31 Q...P328 end P47 Shade Styles may be specified with SNC Cordset Finish only. <:!IlcuityBrands 1300 S WoH Roo0 Des Plames. I Phone 18.a7! Fox VI5 1 us ot :>rond5com/lunoifoc Prm ed In US A Acu"r-f Bronds lighting. Inc Rev 06/26/17 2 of 7

159 G2 DECORATIVE PENDANTS LOW VOLTAGE - LED DPEND SERIES SHADES DIMENSIONS P45: Creote a mogical auro in three traditional colors with the versatile P4S cased etched glo$$ tall dome shade. Amber 101/4' J Frost Lime ~4...j P47: The PA7 Forgo gloss shade features a hond-crafted design inspired by the fury of a winter storm. Blizzard 61/4' -..J P52: The P52 dome shade is cut from natural Onyx stone and polished to a beautiful finish. No two shades ore exactly alike. ill Amber White 1- ' 37J8'~ Onyx Onyx P61 : The P61 cased etched medium flute glos$ shade is topped with a finial thot completes its tapered shope. Amber Opal P68: The hond-blown P6S teardrop-shaped glass shade comes in 0 dramatic, hanckrofted Amber Storm finish. 11/2' Amber 4112" Stonn P88: Choose from three dramatic looks with the PBB glass ellipse shade, a striking addition 10 any room, ' \1 91/4' Amber Storm Sundae Radiant Red ~cuitvbrands 1300 S Wolf Road De5 Plaines, Il 0..."018 Ph::;ne 1847) Fox 18A7) VIS;I us 01 wwwocvltybrorlds com/lui'io"troc Pnn'eel In USA A:vty S'C'1d5 lighting, Inc Rev 06/26/

160 Project Fixture Type: location: Conlacl/Phone: PRODUCT SPECIFICATIONS Transformer Operating Environment Designed for 40,000 hour operating life with repealed switching in 40' C ambient and 95% relative humid ity environment. Designed to withstand the intense heat produced by incandescent troc lighting. Toleroles susta ined case temperatures of 100 C All components meet figid heal tolerance standards and pass over-temperature life lests. Transformer Agency Ratings En Certified for use in the U.S. and Canado FCC Certified 10 Closs A noise limiting standards. Controls radio interference & provides quiet operation with or without dimming Exceeds IEEE line Transient Requirements. Provides superior spike protection. Tronsformer Compatibility and Mechanics Transformer adapter may be used with T rac-master or T rae-lites Series tra c (or designated monopoinb) and all Juno Quick Jack fixtures and pendants Designed using a Hatch RS 12-60M-lED transformer Compatible with most 12VAC LED lamps (by othersl- contact lamp manufacturer to confirm compatibility Also compatible with 50W max. 12VAC halogen lamps. Housing High impact polycarbonate housing. Integral on/off switch Available in white, block or silver finish. Trac Adapter Copper a ltey contacts provide precise spring action - no arcing and will not take a set True, positive electrical ground. Patented embossed polarity arrows on bottom of adapter H Pul~up N contact to up position for two-circu it application. Dimming Incandescent and LED loads can be dimmed with high quality reverse phase dimmers designed specifically for use with e lectronic tra nsformers. Specifications subject to change without notice TRAC-MASTER Low Voltage LED COMPATIBLE 12V ELECTRONIC TRANSFORMER WITH QUICK JACK ADAPTER T537 QJ DIMENSIONS Engineering Data Input Nominal Output Operating Frequency Power Factor T.H.O. Operating Ambient Humidity Rated Average life Third Party Qualifications: 1In r- 57/B"~ ;Z~3/4" 114"~ 1 114" 120VAC,0.52A l1.5v, 50 Watt, (VA) Max. load >20kHz >95% <20% 0.95% RH 40,000 I 20VAC ;nput 40'C a mbient FCC Certified under CFR, Title 47, Pari 18, Classes A & B. ETl Cerli~ed for US & Canada. ORDERING INFORMAnON Ord,,;ng bompl QJ LED WH Strios Mounting Ado"", led Compao;b;5ty Finish V Input, tow Profile Electronic Tronsformer I IQJ Quick Jock Adoeter I IlfD ted Compatible I at Blod< ~ Sil:.:" IWH While I ~cuitybrands 1300 S Wclf Roaa Des Phnes, IL 6iXJ1 8 Ph:fle (8A7) Fo){ 1847) VIS'! us 01 wwwocultyb'ondscom/lunoirac Prm'ed m USA Cl20 17 Acu'Y 8rond~ li9h~n9, Inc Rev 08/28/

161 juno Project C i!o~~~~,.1j 7d/c. ~ ~~ ~~'--- Fixture Type: location: ~I~ D2.1.12G2 TRAC-LlTESTM low LED R600LG2 Contact/Phone: PRODUCT DESCRIPTION The R600l G2 Series low LED is on economical and affordable trac fixture, with a simple and timeless aesthetic. II approximates the light output and distribution of SOW MR 16 halogen lamps, utilizing about 20% of the energy and having a roted life of 50,000 hours. Versions are currently available in 2700K & 3500K color temperature with minim um 80 CRI. Oplional97 CRI versions are also available in 2700K, JOOOK. and 4000K color temperatures The R600l G2 Series LED is available in spot, narrow flood and flood beom distributions which can be achieved with interchangeable precision.molded custom optics. It is compatible with Juno Trac-lites and Trac-Masler trac and system components. PRODUCT SPECIFICATIONS Construction Die cast aluminum heat sink provides outstanding thermal management of LED, yielding 70% average lumen maintenance at 50,000 hours of operation. Simple, timeless design complements ony decor. Available in while, block, bronze and silver finishes. LED High performance LED array provides outstanding reliability, performance and color quality/ consistency. 2700K, 3000K, 3500K or 4000K white phosphor high performance LEOs. Exceptional 80 CRI minimum available in 2700K & 3500K CCTs Optional 97 CRI minimum available in 2700K, 3000K, or 4000K CCTs Chromaticity range within a 3-slep MacAdam Ellipse. Driver Integrated into fixture housing behind LED light engine to minimize overall fixture footprint Insulating air gop between driver and LED light engine, plus thermal potting compound, optimizes thermal operation Provides quiet operation with or without dimming Dimmable using high quality, factory-opproved dimmers see R600LG2 DIM Solid state electronic, Closs 2 compliant Integral overcurrent and short circuit protection Designed for greater than 50,000 hour operating life. FCC Certified to Port 15 Class B EMI standards. Optics Proprietary, interchangeable thermoplastic lenses available in three factory<onfigured beam spreads Indicate specific beam spread desired or specify universal version which includes both narrow flood and flood optics Accessory optics also available to enable simple beam changes in the field. Lensholder Bayonet mount lenshalder facilitates optics changes in the field. Adapter Copper alloy contacts provide precise spring action - no arcing and will not toke a set True, positive electrical ground On/off switch included Patented embossed polarity arrows on bottom of adopter. Spring.loaded positive latch with embossed polarity arrows secures troc fixture to troc H Pul~up N contact to up position for Iwo-circuit application. Aiming horizontal coverage vertical aiming capability. Labels Ul cnd CUl ".Ied ENERGY STAR" Cert;l;ed DlC Gluol;ned 90 CRI cnd 97 CRI versions certified as CEC Tide 24 Compliant. Union mode. Assembled in U.S.A. Warranty 5-yeor limited warranty. Complete warranty terms located at: stomerresources IT erms a nd condition s. asnx. Specifications subiect to change without notice. ORDERING INFORMATION - Serio. Colo. DIMENSIONS O,de';'9 E,omp. R600l G2 27K 97CRI PDLM Nfl Bl Colo. TompenoOn Rondoring Index Distribution Finish ~ty ;;2./ p R600l T,oc.utes" Economy Generation 2 27K! 2700K, SOCRJ SOeRI ~ PhOHl Fl Flood 8l Block Cone LED /' r 3OK ' 3000K '" 90ClIl 90CRI " Dimmable.,...; r:'!l Narrow Flood 8Z Bronze /" 35K' 3500K 97CRl 97CRI SP SpOI SL Silver 40K' 4000K UNF Universal.,WH White Narrow flood,"" Flood Notes: I 27K nol ovailoble will! 90CRI ot /hij ~me. ACaSSOR S 2 30K not available willl SOCRI 01' 90CRJ o1l1lis fime. nr4spt 8lCK TlR Optic. Spot. Block TlfNS4 NFLD lens - Narrow Flood 3 35K nol available with 90CRI or 97CRI 01 this ti me. nr4sptwht TlR Optic - Spot- While TlENS4 FlO Lens - Flood 4 40K not availa ble with BOCRI at this ~me. ~cuitvbrands 1300 S WoK Rood Des Plolnes. Il Phone 1847) Fox (8.47) Visit us 0 1 wwwacijltybrondsc.om/ tufloiroc P'lnledmUS A 2017Acu'tyBlonds lighting, ir1c 07/21/17 101'2

162 ~OIt'l"'~"" ' rj 7.3/.') TRAC-MASTER Project: ~( _ --- Two Circuit Trac System '-'-' FiX= IUre"'-Ty- pe-: location : Conlacl/ Phone: TRAC SECTION, JOINERS & FEEDS TU Series PRODUCT DESCRIPTION low-profile, two-circuit Iroc sections for surface or pendant mounting. Provides two separa te 20-0mp circuits from 0 sing le electrical feed or one 2(H,mp circuit controlled by two switches. l-beam cross section provides added strength and rigid ity in penda nt suspended applications. Compatible with 0 full range of feed, connector a nd mounting accessories, as listed on bock of this page, to complete virtually any installation requirement. Accepts all Trac-Master and Trac-lites troc fixtures, which have a moveable "hot" contact to allow operation using circuit (or switch leg) 1 or 2. PRODUCT SPECIFICATIONS Construction Extruded aluminum "I" beam channel. One-piece thermoplastic insulator. Injection molded polycarbonate dead-end with set screw Standard lengths may be cut.to-length by installer. Elenricol Three 12 gouge solid copper conductors Each circuit rated 20 amps at 120 volts (40 amps total) Aluminum channel used as system ground. One-piece insulator insures consistent conductor spa cing for reliable electrical contact Insulating bushings supplied at mounting hole locations to prevent shorts to ground. Labels Ullisted, CSA certified. PRODUCT INSTALLATION Debossed polarity line provides visual cue to proper troc, trac connector and fixture alignment. Supplied w ith loggle bolts for surface mounting. Integral raceway in top of channel accommodates pendant mounting hardwa re and wire routing to electrical feed Insulator stays same length as extrusion to simplify field<utting of trac Connectors and feeds sim ply push into trac sections. Specifications sub ject to change without notice. DIMENSIONS INSTALLATION GUIDE Use two switches for greater control, two circuils for greater capacity. c _ Switch1 (Products "A") c _ Switch2 (Products "8") A 8 A 8 Where wattage requirements are 2400W or more the trac run may be fed from one point, providing 481NOOW capacity plus 2 switches. One Circuit with Two Switches 2400W Max. Two switches may be used on each trac run with a portion of Trac fixtures run by Switch 1 and the balance on Switch 2 Dimmers or Timers also can be utilized to provide other lighting effects along the run. Two Circuits with Two Switches - 481NOOW Max. Two..Circu it T racmosler provides a load capacity of 481NooW (two 2400 watt circuits) using split phase common nuetral circuit This "double capa city" eliminates 50% of the feed points in long runs reducing wiri ng costs and simplifying the installation Two separate circuit switches permit flexibility in combining lighting effects along the run. ~ ORDERING INFORMATION Series Length Finish TU Troc-Moster 2-Circuit Track Sections 4FT 4-foot trock section; actuol lenglh 43-7/8" BL Block 8FT a-fool trock section; actual length 91 7/8" SL Silver...;,.12FT 12-foot trock. section; actual length 139-7/8'"...:: " WH White E xomple: TU 8FT W H ~cuitybrands 1300 S wolf Road Des f1oines, Il t:lxji8 Phone [ Fax 1847) 827 2Q25 VISit us ot WNW ocultybronds com/junoffoc Printed In USA C20 17 Actll!)' Blonds lighting. Inc Rev 03/01/17 1 of 6

163 D1.1.1 TRAC-MASTER Two C ircu it T rae System TRAC SECTION, JOINERS & FEEDS TU Series Trac Joiners & Dead End LI TU20. \.tu23"- BL, SL, WH BL, SI\.WH \ Accordion Adjustable Joiner (on flex to 90 0 angle to left, righi, up Of down. Joins two troc sections. I Miniature St;:arght Connedor Joins two troc sedlons eoo 10 end. ~ ~ H 3/8" TU26, Bl, SL, WH "X" Connector T27 BL, SL, WH Outlet Box Cover Joins four troc sedions 01 90' angles. Use with Nos. TU74/TU7S/TU76 For outlet box feed, T27 cover piote for OlIIkt box electrical feed. klckides: required. nipple, kkknut 0tId groond, screw. 1/2" ~ M ~ "" 4 1/8" r- 4" sq.'" Examples: TU20 BL, TU25 R W H TU24, TU2S, TU2S R, BL, SL, WH BL, SL, WH BL, SL, WH Adjustable Connector "1" Connector "T" Connector Joins two Iroc sections 10 make Q 90' Joins Ihree tloc seclioos. FOf outlet Same os T25 ex<epl desiglled for angle Of straight run. Stroi~1 and ri~1 box feed, tkl. 127 (DYe! pmle use in Dllposite polarity Ofienlotion angle {OVefi supplied. FO{ ourlel box feell, required. {~red 10 sfondofd feed (oooectoo. No. T27 (over piote re1l ~red. ~----. <:> : ~ ~.:/:-:,:' ~ r I I 2 1/16" 4 118" ~ '-!.U28 ~ -" TU3S BL,S~~ BL, SL, WH :- T-Bar Adjustable Joiner Troc Dead End Feed For use with hekkullro( sections. Joins two ltoe sedions to mole 90 angle or stroiqhtl1xl. Wiring comportment cootoins standard 1/2" lo's. feeds hom oboye when loor is directtv above trac. ~ ~ 4~8" * TU24, TU25 and TU26 may nol be used as feed connectors in Canada_ ~cuitvbrands 1300 S Wo ~ Rood Des PIoines. IL 6OJ 18 Phone l Fox 1847) VISit us at wwwocultybrarldscom/junoirac Printed In US 1 7 AcUity Brands lighting. Inc Rev 03/01/ I 7 3 0/ 6

164 TRAC-MASTER Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS TU Series Electrical Feeds TU21~ BL, SL.{WH'F" End Feed Co~ dor and Outlet Box Cover TU21 R BL, SL.. WH End Feed Connector and Outlet Box COYer f~ ooiiel box feed. k1<kjdes: oollel box Same as T21 except designed lor cover, fixture Slrap and ground screw. use in opposite polarity orienlllfigll compared to stonoord feed (Onnedrns. 4" ~. ~1f 1 6" Examples: lu21 Bl, lu34 R W H TU29 TU34 TU34 R BL, SL, WH BL, SL, WH BL, SL, WH Floating Electrical Feed Conduit Feed Conduit Feed Pennik mooolilg any point of Iroc for surioce 'Ninno. Use stondord vr Some as TU34 except desig~ for use under outlet box. Irdldes f\oofing (OIlnectOI. in opposite polarity Ofientotioo compared {onne<lor, outlet box (over ~us emc 10 standard feed (onnectors. troe dead end. ~ '- 4 5/S"-< 3" f---'-l ~"\1 1 /4 " TU36 BL, SL, WH TU36 R BL, SL, WH TU38 BL, SL, WH TU38 R BL, SL, WH T-8or End Feed 1-8or End Feed Live End Feed Connector Live End Feed Connedor WrillQ comportment (ontoins sllllldord vr ko's. Feeds surface!roc from '""" when T.oo., d <1fy me hoc. Some as TU36 except designed for use in opposite polarity orienlolion comp!hed to stoodord f~d connectors. Fee<llroc from obove with flexdie conduit, BX, etc., Of eoo f~d in pendant systems. Some 05 lu38 except designed for use in opposite poiority orientotioo compcxed to stoodord feed connectors. ~ ~S " ~ 1 311S " 1 ~cuitybrand S wolf Rood. Des Plaines, Il CIJ018 Phone 1847) 827.Q880 Fox 1847) ViSIt us at wwwacultybrandscom/juno'troc. Pllnted In US A <02017 AD.1lty Branch lighting. K Rev 03/01/ J 7 2 of 6

165 Project: Fixture Type: location: Contoct/Phone: c D1.1.0 TRAC MASTER One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series PRODUCT DESCRIPTION low-profile, single-circuillroc sections for surface or pendant mounting_ l-beam cross section provides added strength and rigidity in pendant suspended applications. Compatible with a full range of feed, connector and mounting accessories, as listed on bock of this poge, to complete virtually any installation requirement. Accepts all Troc.Mosler and Troc-liles troc fixtures. DIMENSIONS PRODUCT SPECIFICATIONS Construction Extruded aluminum " I" beam chonnel One-piece thermoplastic insukllor Injection molded polycorbonote dead-end w ith set screw Standard lengths may be cut-tchength by installer. (Iectrical Two 12 gouge solid copper conductors. Rated 20 amps at 120 volts Aluminum channel used os system ground. One--piece insulator insures consistent conductor spacing for reliable electrical contact Insulating bushings supplied 01 mounting hole locations 10 prevent shorts to ground. Labels Ullisted, CSA certified. PRODUCT INSTALLATION Debossed polarity line provides visual cue to proper trac, trac connector and fixture alignment. Supplied with toggle bolts for surface mounting Integral raceway in lop of channel accommodates pendant mounting hardware and wire routing to ele<:lrical feed Insulator stays some length as extrusion to simplify field<ulting of trac Connectors and feeds simply push into trac sections. Specifications subject to change without notice. ORDERING INFORMATION E xample: T 8FT WH Series Length Finish T TracMoster 1-Circuil Track Sections 2FT 2-foot track section; actualleng,h 19-7/8" 4FT 4-foot track section; acluallength 43 7/S" 6FT 6 fool track section; actual length 67 7/S" 8FT S.foot tra ck section; a ctual length 91.7/8" ~ 12FT 12 fooltrack section; actual le ngth 139.7/S" BL NAT SL WH Block Natural Silver White ~cuitybrands 1300 S Wolf Rood Des Plaines, Il6O'.)18 Phor.e Fox V,Sit us at wwwacllltybrandscom/juno'tfoc Prmted m U 5 A ~20 17 AI:;v,ty Brands lighting, nc Rev 03/01/17 1 of 6

166 D1.1.0 TRAC-MASTER One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series EI ectrlca IF ee d s / ~ 1 ~ T21 R BL, SI),.WH ) Bl, SL, WH End Feed Co~or and Outlet Box Cover For outlet box feed. kkludes: outlet box (over, fixture strop ond ground snew. End Feed Connector and Outlet Box Cover Some as T21 except designed for use io opposite ~larity o ri enla~on compared 10 slondord feed (OIUJeclors, 4" ~" ~ " E xampes: T2 1 Bl T3 4 RWH T29 T34 T34 R Bl, SL, WH BL, SL, WH BL, SL, WH Floating Electrical Feed Conduit feed Conduit Feed Permits lt1oufi~ng any poinl of tree FOf surrace wiring. Use standard l/ 2 ~ Some as 134 except designed lor use in under ootiel box. lnoode.s fioomg connector. opposite polarity orientation compared to connector, outler box (over pm extra stondard feed (ormeaors.,,, deod end. i h I-4 5IS"---' 3" >----< ~"\l 1 14 " T36 Il, SL, WH T36 R BL, SL, WH T38 BL, SL, WH T38 R Bl, SL, WH T-80r End Feed T-Bar End Feed Live End Feed Connector Live End Feed Connector Wiring comportment contoins stondord lj2 w KO's, Feeds surface troc from above, when T-bor is dired~ above troe ~ v.(;;'s" Some os T36 except des~ned for use in opposite polarity orientation compored to sloodord feed connectors. Feed troc from obove with flexible conduit, BX, etc., or end leild in pendant systems. Ac(epts stonoord 1/2" (011_. ~ '311S" ' Some as T38 except designed for use in opposite polarity orienlation (OmporeillO stoodord feed (Onnectors. T22 BL, SL, WH T122 BL, SL, WH Cord and Plug Connector Cord and Plug Connector Comes with 1 S' two-wire white (Old. Indudes surfoce wire relainers and in-line switch. Max cop. 7 amps. Not Ul listed. 3~ ~ Some os Tl22 but with matching wlor 3-wire grounded cord Ofld plug. No switch. Not Ul Usted. Outrigger System T47 BL,WH Outrigger Bracket (non-electrified) For mounting troc Oul from won. Use two for 2', 4' or 6' troc sedions, three for 8' troc sections 000 four for 12' troe sections. Order trot and (anne<lcrs sepolote~. For portoble electrkol feed, use T22 or T122 Cord 8. PkJg Connector. For permanent wiring, use T38 end feed connector. 24", ~S"... ::::::: :<:<::~ '.. ; ~cuitybrands t 300 S Wolf Road Des Plomes, tl 6CX) 18 Phone ( QSSO Fax ( VISit us at www acliltybland~ com/jlinoiroc Punted In USA Aculry Blonds lighting, Inc Rev 03/01/17 2 of 6

167 DI.I.O TRAC-MASTER One Circu it Trac System TRAC SECTION, JOINERS & FEEDS T Series Trac Joiners & Dead End T20 BL, SL. WH Accordion Adjustable Joiner COIlI\eX to 90 ongle to left, light, up or down. Joins two troc se(~ons, T23 BL, SL, WH Miniature Straight Connector Joins two ttl]( sections end to end, ~ ~ H 3/8" Exa mples: T20 BL, T25 R WH T24! T24 F! BL. SL, WH Adjustable Connector Joins two IToe sertioll$ lo nhlke () 90' ongle or straight run. Straight end right angle covers supplied. For ootlet box feed, No. T21 (over ~ate req1jired. BL. SL, WH Adjustable Connector Same os T24 but with integra! ground (oonectioo. For outlet box feed, No. T27 (over plale required. ~----. co ~ ~ :.::~:_:,:; r------; 21 /16" T25! T25 R! BL, SL, WH BL, SL, WH T25 F! T26! T26 F! BL, SL, WH BL, St, WH BL, SL, WH "T" Connector Joins!hr~ trac sections. for outlet box feed, No. 127 {over plote required. "T" Connector Some as T1S except des~ned for use in O!lposite polarity orientation wmpmed to slondord feed connectors. " T" Connector "X" Connector " X" Connector Some as T25 but with integral gfoljlld Joins fouf trot m~ons ot90' angles. Same os 126 blll with integral ground {{)linertion. For outlet box feed, No. 127 for oo ~et box feed, 127 {over piole {oonectiorl. for outlet bo~ feed, No. (over plote required. required. T27 (over ~ote required. T27 BL, SL, WH Outlet Box Cover Use with Nos. T24/T25/T26 f. ou~et box electrical feed. IncWes: nip~e, locknut ood ground soew. ~ I I 41/8"..L \..r.28 '\ BL, SL\ WH I TracDea~ for use wirh fiekkilt troc sections., 1/2" ", 0 ~ f-- 4" sq.-; T35 BL, SL, WH T-8ar Adjustable Joiner Feed Joins rno troc se<tions to make 90 angle or straight run. Wiring comportment contains standard l /Z~ KO's. feeds from obove when lila! ~ directly obove troe. ~ T49 Bl, Sl, WH Trac Continuation Kit PermilS troc to continue 0 run around obstructions.lnclums one left ond Gne right T34 (Gnduit Feed. FilS standard liz" cgnduil. ~ rr 4~8" ~ ~ 4 118" ;: T24, T25 and T26 may not be used as feed connectors in Canada due 10 special grounding requiremenh - T24F, T25F & T26F are approved for use as feed connectors in Canada (may also be used in U.S.). ~cuitvbrands 1300 S Wolf Rood De~ Ploine~, Il t:jjoi8 Phone Fax (847) VISI! us 01 wwwocullybrondscom/jul'\o-mc PrlfltedmUSA 2017AcultyBrofldsllgfllifl9.lnc Rev 03/01/

168 ,~ - L/THDN/A L/OHT/NO" FEATURES & SPECIFICATIONS I NT EN DE D USE -low-profilt> stat;c luminai/i! provides genet.11 illumination felf recessed applications; ideal for restricted plenum spaces. (ettain airborne contamina nts (an diminish integrity of acrylic, (lick bere for Auylie Environmental Compatibility table fo r sujhble uses. Attributes: Designed mluslvely for use with T8lamps, eltel/onie ballasts and sockets. CONSTRUCTION - Smooth hemmed sidl'! and smooth, inward formed end flanges for safe handling. lighter weight hlllre allows for safe, easy installation. Standard steel door frame has superior structural integrity with premium extruded appearance and precision flush mitered (orners. Steel door allows easy lens replacemelll without frame disammbly (for lenses up 10,156" thkk). Powder painted, ~ te el lat [ h es provide easy, secure door closure. Superior mechanical light seal requires no foam ga~ke ti ng.lnlegfat T-bar dip~ secure fiklure 10 T-bar system. Housing fo rmed hom (old-rolled ~teel. Acrylic shielding material 100% UV stabilized. Na asbestos is used in this praduc{. Finish: Five-stage iron-phosphm pretr eatment ensures superior paint adhesion and lust resistance. Painted parts finished with high-gloss, baked white enamel. ELECTRI CAL - Standard ballast is electronic, thermally protected, resetting, (lass P, HPF, nan-pcb, Ul listed, (SA { 'Itified ballast, univl'rsal voltage and sound ratl'd A. Luminaire IS suitable far damp locatians. AWM, TfN ar THHN wire used Ihroughaul, rated lor required tempmtures. MVOLT ballasts are Full light output - redu(ed energy. Less than 10% THO, Multi-volt operation, V. LISTINGS - StandaTd: Ul. WARRANTY - 2-year limited warranty. (omplete warranty te r m~ lomed at and conditions mx NOTE: Actual performance may differ as a result of en d -u~er environment and application. Specifications subject to change without notice. (atalog Numbtr Moln T", GT Contractor Select Troffers ~ '. lgt 61Spt(ificallom length: 48 (121.9) Width: 24 (60.1) Depth: 3-1/8 (1.9) 161SpecificotiDns Length: 24 (60. 1) Width: 24 (60.1) Depth: 3-1/8 (7.9) AU dllrltn\.lons irf In(1in ((tntlllltltl'l) :>, (JUlog.. NUIIIHr UP( Otsaip1ion ~mp s Wiiltn~ GTl MV K4 troff~r 1 11 GT2lMV HS x4 troff~r 11 G12LWMV x4 Holfer 11 GB2MV H S10 2x4 trolf~r 11 GBMV H x4rroffer 11 GntMV 7( x4 Hoffel 11 GT3l]MV x4 troffer 11 Gm41 MV ( trolfer 11 GT3lWMV ( x4troittf 11 GT3l41WMV 74591Sm rofftf 11 GI41MV x4 trofft! 11 C,I4MV trofftr 11 GT4I.MV trofftr 11 GI4l41 MV tlolfn 11 GUl41WMV 74597Soa15H b:4tloffrr 11 GT4lWMV lx4troffrr 11 G12UMV x1 troffer H-Ulamp GTlUlWMV x2 tloffer l1-u lamp VO~t m m n Prt- I". WI'" Ele<tronk,!nslan! start [Ierlr<lnie, inllant start Ele(tronlC, Inmn! star! ElectronK, Instant stan EIl'{tronic, instant starl [Il'{tronk, imlant stan Electronic, instanlstart [1«lronlc, list ant slirt I«tronk, instant start (tt(!loruc, instint stan ElectronK, instanl stall EiectrOOl(,lnstanlllin Eie<tronic, instant stan Ele<trornc. instant stan, Electronic, IllStant start Y Electronic, Instant start Eie<tronlc, instant start Elettroni(, instant stall..,...,... hl1t1 hlliilns lip' IIIdu4ed Q1y. HI., 3500K 3500K 'fa N/' 3SooK )SOO< 41001< 1-,,,111< 'fa, " HI. H K Y "'" 4100< " 1-18 HI' )( 56 CONTRACTOR SELECT I FLUORESCENT TROFFERS_LENSEO

169 Troffers MOUNTING DATA DIMENSIONS ---,Jl.~_ G Lay-in Grid (exposed or concealed grid) L <IT \$, <IT ~,)" ~~-=======j!t======~=~(8e 24 I (60.9) ,116 ~ ~ I 117.8) -y ~ L<lT t 9 <lt I L 24 (60.9) L t I (17.8) (6.5) 1 <IT \Sfl <IT <IT?" --li ~8E I I~'" jl PHOTOMETRICS (a\(ulated using the lonal cavity met~od in a((ordanct with IESMA LM.l pf(lctdult Floor,~Of(tan(t5 art lamp (on1iquraiiom shown art typical. full photome1rlc data on tht~ and otlltr configurations available upon request. GTlU MY CiT3MV Report LTl75J4 Report ttl 7421 Lumens per lamp lum. eft. 80.1% lumens per lamp tum. eft, 71.9% S/MH (along) 1.2 (across) 1.4 S/MH (along) 1.2 (across) 1.4 Coefficient of Utilization Coefti<ient of Utilization (tiling 80% 70% 50% <t~"9 "" ''''' '" Wall 70% SO% 3QI!& 70% 50% 311% SQ% 30% JQ9f, W:tllzre~ SIl'!!t 311'. 1M!: 5!l'l1: 1!I5~ SllO 3ft1!!,!!: " " " <i " ' l l II 38 II II II II B ' l ' Zonal Lumens Summary Zonal lumens Summary 19n. Inmtcs "lild!) '!!fij'!litr looe Illmeos %Iamp %fixtwe l S0 17.S (l M (l (l CiT4MV Report L1L 7425 Lumens per lamp Lum, eft % S/MH (along) 1.2 (across) 1.4 Coefficient of Utilization (tiling 80% 70% 50% Wall 70% 50% 10% ZIl% SQ9f, 30% 50% 30% JO% , l II lonallumens Summary Zone Ilimens %I amp %h(tme (l ,-~ L/THDN/A L/GHT/NG' An<-<AcultyBrands Company TROfFERUENSEO CONTRACTOR SELECT 1 FLUORESCENT: Doe lith()jiiii Way Conyers, GA Poone' Fax: 77G Wo<ffl.lrthonia.col1l c Acuity Brands lightmg, Inc. AI nghts reserv~. Rev.06103/15

170 ,~ - L/THON/A L/SHT/NS' utalog: Numbl'f Not~ FEATURES & SPECIFICATIONS INTENDED USE RfctSsed housing Tartt! I( Of Non-K. for new wnslru<licm only. Approvt'd foi all ceiling and wiringlypes. Approved for direct burial in insulation, CONSTRUCTION Air-tight standard. Tested to meet (Uflen! energy (odes, Aluminum foam-gaskeled housing with galvanized steel pan. Galvanized bar hangers span up 10 24ff o.c and feature built in nailer and integral T-bar clips. Two locking screws hold fixture ill position. Galvanized steel junction box with four built-in Ramex damps; five 'W and two %N nominal knockouts with slots for pryout. Rated for thlough btalkh wiring. Maximum 4 (2 in, 2 out) No 12 AWG conductors. Rated for 9Q G e. Ground wire provided. Removable J-box doors for easy a((~s. Trim retention (lor ): Two s ide~mounted torsion springs on the trim and 2 receiving brackets in the can ensure a consistfntly tight fit with the cfiling. ELECTRICAL Quick disconnect provided for power mnn«tion to the LEO modulfs. Paint overspray masked by dispo5ablf disconnect plug. Housing and LED module combination is I( rated and thermally protectfd. 120 volu onl y. INSTALLATION Air tight housin9 suitable for air-ti9ht installations. Refer to ener9y codes for proper installation. 2 x 8 wood joist or T-bar insta llation. Expandable bar hange~ allow fo r off center mounting in wood joist ort-bar {eilings. Length of 25 %" maximum 13114" minimum or wt to fit 9" on center joist consl rudion. Vertical adjustment of housing allows for nush mounting with ceiling face. Suitable to ceilings up to 1-1/2" thick. LISTINGS Ul lhted to US and (anadian safety standards. Wet location listed, Title 24 compliant. WARRANTY - 1-year limited warranty. (omplete warranty terms located at wwwacuitybrands.comicustomerresqurm /Terms and condilions. clsdx Note: Actual performance may differ as a result of end-user environment and appliul ion. Spedfications subject 10 change without notice. B-1/!: (ls.2j W (UI) 6" LED Housing L7XLED 124 LED IUNon-1( New Construction Sp«itKations Height: 6-7/8 (1 7.5) Length: 15 (38.1) Width: (35.2) T' IfUI"""OI "" (eiling wtout: 7 (17.8) -1==---- I~lI -----==1 All dimensions are inches (ct ntimmrs) units! olht rwlse specifitd, option 277V step down transformer ORDERING INFORMATION Fonhortpst Ifad times, configure products using bolded options. E xamp e: L7XLED 114 ~. l 7XLEDT24 Series Options ~ l 7XlED T24 SOT 277V Non-IC 277V step-down transformer t277v to nov ). Only available with REAliTY LEO Mod ule (REAl6) Pa<kaging R6 Resale pack of six U Unit A«usories: Order os stparare (atalog number. ATK6 R6 HS687S 6" Air-tight trim kit 6 7/8" hole saw DOWN LIGHTING l7xleo-t14

171 ,-~ L/THDN/A L/OHT/NO FEATURES & SPECIFICATIONS INTENDED USE - Our recessed led module is thl.' most economical means to create a well Ii! erlvironment with exceplional energy efficiency and near zero maintenance. Great for retrofit into existing downlight cans or new (onstruction and remodel applications. Unique torsion spring and fr klion dip retention allows fitmtnt into nea rly 100% of installed cans. The LEO module maintains at Itast 70% IIghl output for 50,000 hours. CONSTRUCTION - Aluminum die cast refintor with deep baffle configuration foi/educed glare. Combined LED and driver printed circuit board attached. Inner reflector cone mnntls light through the pressed-in diffused lens. Baffle and open trim inserts arf available in multiple finishes. OPTICS - Diffused lens at end of mixing chamber to provide even tight distribution for general illumination, equivalent to 6SW BR30 or l00w BR30 lamp. Wide flood beam ang le at >45. ELECTRICAL - (enter 2 Edge'" (patent pending) technology (reated for a single point source. Prima ry power disconnect provided for simple connect ion to a dedicated LED connector in the housing. Dimming down to 10%. For compatible dimmers, reler to (omdjllble Dimmers (halt. 725-lumen P selies has an input wattage walls, 57 lumens pel watt, equivalent 10 6S-watt incandescent. P Series' patent pending driver has zero inrush, which allows power loads to be calculated With actual raled wattages. Example: 47 units of 6BPMW LED fixtures can be installed in line with a 600-watt dimmer. 600W/12.7W = 47 fixlures. 9S0-lumen P series has an input wattage of 15.2 watt s, 63 lumens per watt, equivalent 10 loo-watt incandescent. "Actual wattage may differ by +1-5% when operating at nov +1 10%. INSTALLATION - Suitable for installdtion in standard and shallow-height Tough-in sections. E26 soc.et adaptel and splice kit ships standard. This enables easy installation or permanent {onvefslon to an LED source for Title 24 compliance. TWin 10lsion splings ensure easy installation. Friction dips included to allow fitment into cans without torsion brac.ets from an inside diameter of 6.0 to 7.0. LiSTiN{jS - (SA certified to US and Canadian safety standards. ENERGY STAR- qualified; (alifornia T24 compliant. Wet location lihed for indoor use only. WSE( ASTM E283 for Air-Tight (with J( housings). WARRANTY - S-year limited warranty. (omplete warranty terms located at and cond itions.asnx Actual performance may differ as a result of end-user environment and application. Note: Spedficatlons subject to (hange without notice. PATENTS PENDING. Torsion mount shown Friction dip shown (included) Specifications / Aperture: ) Ceiling opening: Determined by rough-in Overlap trim: 7-1/8 (19.4) Height: (9.8) ~ Center2Edge' All dlm/.'f'iiions ar ~ inchl.'s Icentlmtttfsll.lniflS othtrwist indiultd. LED Rece"ed Downlighting 6BP/60P E26adaptor (i nclude d) 6" LED Module IClNon-1C Retrofit tldcaiidn' Spli(t icit (included) t.mp CCT I CRI / W ILumens ' Voltage Options 6" Baffle LEO module, matte white LED (blank) 3000 K 183 (RI 112.7W / 725l (bldnk) nov 17XLEDT24 6BPTRMW 6" Baffle LEO module, blac. baffle, matte 27K90(RI 2700 K 193 (Rl / l1.2w / 6001 l7xrleot24 white nange 30K 90(RI 3000 K 193 (Rl / l1.2w 1600L 1(6lE0124 6BP8N 6" 8affle LEO module, brushed nickel 40K 9IXRI 4000K 192(RI / 9.9W 1650L LIX 6BPORB 6" Baffle ted module, oil-rubbed 17XR HLLED 3000 K 183 (RI / 1S.lW 1950L 17XP 2700 K / 93 (RI/16.5W /8601 l7kpr 3000 K /93 (RI / 16.5W /8601 LC6 4000K 192(RI / 16.4W /9501 LCP 60PA 6" Open LED module, dear diffuse LED (blank) 3000 K 183 (RI / 12.7W 1725L I b~nk) nov t7xledt24 60PAZ 6" Open LEO module, dear specular 27K 9{)(RI HOD K 19) (RI 111.2W 1600l 17XRlEOT24 60PA TRMW 6" Open LED module, clear diffuse, matte ]OK90(RI 3000 K 193 (RI / 11.2W 1600L t(6lfo T24 whitenange 40K 90(RI 4000K/ 92(RI 19.9W /6S0L LIX 60PA2TRMW 6" Open LED module, clear specular, matte L7XR while flange HLLED (blank) 3000 K 183 (RI / 1S.2W / 950L LlKP 27K 90(R! 2700 K /93(RI / 16.SW I 860l l7xpr 30K90(RI 3000 K 193 (RI 116.5W / 8601 LC6 40K 90(RI 4ODOKi 92(RI / 16.4W / 950L LCP New construction rough-in LED base Remodel rough-in LEO base New (onstruction rough-in LEO bm New construction rough-inl Remodel rough-rn l New construction shallow rough-inl Remodel sha llow rough-inl New (onslruction rough -inl New construction shallow rough -in l New (onstluetion rough-in LEO base Remodel rough-in led base New construction rough-in LEO base New conslruction rough-inl Remodel rough -in! New construction shallow rough -in l Remodel shallow rough-inl New (onstruction rough-in' New construction shallow rough-in l Accessories: Order 05 stporate cotalog number. rsa6 Makes non bracket housing compatible with the led module; ships as units, J6 or J2S FL2LED Makt! L7Xf housings compatible with tht LED module DOWNLIGHTING Nolel 1 Toul sysltm dthvtred lumens. 2 Must bt ordmd ona leparatt line See page 1 for Trim Inserts. 6BP- OP LED

172

173 PROJECT TITLE: DRAWING: EUROPEAN STREET SAN MARCO BAR FLOOR PLAN HUGO'S INTERIORS 3139 PHILIPS HIGHWAY N., JACKSONVILLE, FL

174 PROJECT TITLE: DRAWING: EUROPEAN STREET SAN MARCO BACK BAR ELEVATION HUGO'S INTERIORS 3139 PHILIPS HIGHWAY N., JACKSONVILLE, FL

175

176 PROJECT TITLE: DRAWING: EUROPEAN STREET SAN MARCO BAR ELEVATIONS HUGO'S INTERIORS 3139 PHILIPS HIGHWAY N., JACKSONVILLE, FL

177 PROJECT TITLE: DRAWING: EUROPEAN STREET SAN MARCO BAR ELEVATIONS HUGO'S INTERIORS 3139 PHILIPS HIGHWAY N., JACKSONVILLE, FL

178 PROJECT TITLE: DRAWING: EUROPEAN STREET SAN MARCO BAR ELEVATIONS HUGO'S INTERIORS 3139 PHILIPS HIGHWAY N., JACKSONVILLE, FL

179 PROJECT TITLE: DRAWING: EUROPEAN STREET SAN MARCO BAR SECTIONS HUGO'S INTERIORS 3139 PHILIPS HIGHWAY N., JACKSONVILLE, FL

180 PROJECT TITLE: DRAWING: EUROPEAN STREET SAN MARCO COMMUNITY TABLE HUGO'S INTERIORS 3139 PHILIPS HIGHWAY N., JACKSONVILLE, FL

181 PROJECT TITLE: DRAWING: EUROPEAN STREET SAN MARCO COMMUNITY TABLE HUGO'S INTERIORS 3139 PHILIPS HIGHWAY N., JACKSONVILLE, FL

182 December 6, 2017 Matt Reimer Intracoastal Builders Beach Blvd #242 Jacksonville FL Re: Steel Column Repair European Street, San Marco Job Number Dear Matt, On December 1 st, AGC reviewed a sketch sent to us for the repair of a steel column at the European Street Restaurant in San Marco. During the renovation of the European Street at 1704 San Marco Ave, Jacksonville, FL, ICB uncovered discovered that the bases of the existing steel posts are rusted and in need of repair. To do so, you did the following: 1. A ½ x6 x14 long base plate was installed in two that sleeved around the column, allowing for a 4-3/8 hole in the center. The two separate pieces were welded together where they surrounded the existing pipe. 2. A piece of 10 piece of 4 schedule 40 pipe was split vertically. The two pieces were assembled in the field in the hole of the base plate and up the damaged end of the existing steel post to create a sleeve. 3. All members were welded together at their intersections with ¼ fillet welds. 4. The top of the sleeve is welded to the existing post with a ¼ fillet weld. This construction is sufficient to reinforce the existing columns. Nothing further is required. Please call if you have additional questions. Sincerely, Geoff Gartner, PE FL South 3 rd Street, Suite C Jacksonville Beach, FL

183 Spec Seq#: 15 NOTE: Before the circulator is started, the system must be filled with liquid and vented. 1. Set the timer switch to the actual time by turning the programming ring in the direction of the arrow until the timing arrow points to the actual time on the ring. 2. Switch on the power supply to the circulator and set the manual switch to the ON position. The circulator will now start. 3. Set the required ON / OFF times on the programming ring by pushing the programming tabs either away from or toward the center of the ring. Tabs pushed away from the center indicate circulator switched ON while tabs pushed toward the center indicate circulator switched OFF Set the manual switch to the TIMER position. The circulator will now start/stop according to the settings of the programming tabs. 5. For continuous operation, set the manual switch to the ON position. To switch the circulator off, set the manual switch to the OFF position. The ON / OFF modes may be used without affecting the function of either the programming ring or the timer switch. 6. In case of power outage the timer will not keep time. After power has been restored, the correct time of day must be reset by rotating the programming ring in the direction of the arrow until the timing arrow points to the actual time on the ring.

184 Spec Seq#: 15 WIRING DIAGRAM FOR TIMER CONTROL ONLY Black White L Timer 2 1 M N Terminal Box Green Pump M L N Capacitor Yellow Blue White Blue 1 2 Blue 3 4 Yellow 5 Timer Capacitor L N Black White Terminal Box Green L T/S White Pump 2 1 Black M N WIRING DIAGRAM FOR AQUASTAT CONTROL ONLY Aquastat

185 Spec Seq#: 15 LIMITED WARRANTY Products manufactured by GRUNDFOS PUMPS CORPORATION (GRUNDFOS) are warranted to the original user only to be free of defects in material and workmanship for a period of 24 months from date of installation, but not more than 30 months from date of manufacture. GRUNDFOS' liability under this warranty shall be limited to repairing or replacing at GRUNDFOS' option, without charge, F.O.B. GRUNDFOS' factory or authorized service station, any product of GRUNDFOS manufacture. GRUNDFOS will not be liable for any costs of removal, installation, transportation, or any other charges which may arise in connection with a warranty claim. Products which are sold but not manufactured by GRUNDFOS are subject to the warranty provided by the manufacturer of said products and not by GRUNDFOS' warranty. GRUNDFOS will not be liable for damage or wear to products caused by abnormal operating conditions, accident, abuse, misuse, unauthorized alteration or repair, or if the product was not installed in accordance with GRUNDFOS' printed installation and operation instructions. To obtain service under this warranty, the defective product must be returned to the distributor or dealer of GRUNDFOS products from which it was purchased together with proof of purchase and installation date, failure date, and supporting installation data. Unless otherwise provided, the distributor or dealer will contact the GRUNDFOS factory or authorized service station for instructions. Any defective product to be returned to the factory or service station must be sent freight prepaid; documentation supporting the warranty claim and/or a Return Authorization must be included if so instructed. GRUNDFOS WILL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSSES, OR EXPENSES ARISING FROM INSTALLATION, USE, OR ANY OTHER CAUSES. THERE ARE NO EXPRESS OR IMPLIED WARRANTIES, INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH EXTEND BEYOND THOSE WARRANTIES DESCRIBED OR REFERRED TO ABOVE. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages and some jurisdictions do not allow limitations on how long implied warranties may last. Therefore, the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction Grundfos Pumps Corp W.118th Terrace Olathe, Kansas Telephone: (913) Fax: (913) Grundfos Canada, Inc Brighton Rd. Oakville, Ontario L6H 6C9 Telephone: (905) Fax: (905) Bombas Grundfos de Mexico, S.A. de C.V. Boulevard TLC #15, Parque Industrial Stiva Aeropuerto C.P Apodaca, N.L. Mexico Telephone: Fax: L-UP-TL-092 Rev.10/05 PRINTED IN USA

186 THERMOSTATIC MIXING VALVE Spec Seq#: 16

187 Spec Seq#: 17 Bulletin G-522 February 2013 INSTALLATION, ADJUSTMENT, SERVICE MODEL 170, 170-LF, 270, 270-USW, 270-LF, 370, 370-LF, 470 THERMOSTATIC / POINT OF USE MIXING VALVES 170 (3/8 COMP) 170-LF (3/8 COMP) ASSE (1/2 NPT) 270-LF (1/2 NPT) ASSE1017/ASSE (3/4 NPT) 370-LF (3/4 NPT) ASSE1017/ASSE WARNING: DO NOT USE THREAD SEALANT ON MODEL 170 COMPRESSION CONNECTIONS 270-USW (1/2 ) ( PICTURE NOT SHOWN ) ASSE 1017 ASSE (1 NPT) ( PICTURE NOT SHOWN ) ASSE 1017 ASSE / 270-LF / 370 / 370-LF / 470 WARNING: When using flex hoses be careful, swivel connectors may damage inlet checks and / or element on outlet on 270, 270-LF, 370, 370-LF and 470 models. Coupling fittings may be needed if swivel connectors have a brass protruding tube or any protrusion that may damage the valve. 1. Valve should be installed where it can be easily cleaned, adjusted or repaired. 2. Inlets are furnished with NPT connections. When soldering close to this unit, DO NOT OVERHEAT, internal components may become damaged. 3. Leonard recommends that unions and shutoffs are installed on the inlets and outlet. 4. Use solder or pipe cement sparingly. Supply pipes should be flushed before the valve is connected. Flush outlet pipe and valve as soon as it is connected. WARNING!! WATER TEMPERATURES IN EXCESS OF 110 F (43 C) MAY CAUSE SCALDING, SEVERE INJURY, OR DEATH!! Maximum Operating Pressure: 125 PSI (860 KPA) IMPORTANT! These thermostatic water mixing valves can be adjusted to deliver water at temperatures exceeding 110 F (43 C). After installation, the installer must check the outlet water temperature and adjust the temperature setting to ensure delivery ofasafewater temperature not exceeding 110 F (43 C). See Temperature Adjustment next page Elmwood Avenue, Cranston, RI USA Phone: Fax: info@leonardvalve.com Web Site: