IFORE Retrofitting Works Outreau. Pre-retrofit Description

Size: px
Start display at page:

Download "IFORE Retrofitting Works Outreau. Pre-retrofit Description"

Transcription

1 IFORE Retrofitting Works Outreau Program : 2952 Address : Georges Braque Street Building year : 1979 Pre-retrofit Description 10 cm width concrete paving Floor Gable end walls Front wall Exterior render Thermal insulation : Garage loft Walls Loft Wood framework Roof Windows House door Heating 5 cm polystyrene insulation under the floor Concrete slab 16 cm width shuttered concrete 14 cm reinforced phenolic foam Sprayed render on front and back walls and painted concrete on side walls 50 mm fibrastyrene 5 cm polystyrene + 1cm plaster on front and back walls 7 cm glass wool with moisture barrier Traditional Slate tile PVC double glazed windows on metallic frame 43 mm insulated metallic door Passive stack Self adjusting air inlets Individual gas boiler for space heating and hot water production Steel heating units Houses pre-retrofit

2 Post Retrofitting Works Specifications 10cm width concrete paving Floor Walls Wall masonry Exterior siding Thermal insulation : Garage loft Walls Loft Base Wood framework Roof Windows House door Heating 5 cm polystyrene insulation under the floor Concrete slab 16 cm width shuttered concrete 14 cm reinforced phenolic foam 8 mm cement fiber clapboards 50 mm fibrastyrene Wood frame/metisse 20cm insulation/rain barrier/siding 16cm cellulose wadding with moisture barrier Roofmate 60+10cm front and back walls Traditional Slate tile PVC Paziaud ventilated windows with rolling slat shutters (hidden lintel) Insulated door between the kitchen and the garage 43 mm insulated metallic door Passive stack Self adjusting air inlets Individual gas boiler for space heating and hot water production Steel heating units Houses in 2014

3 IFORE Retrofitting Works Outreau Program: 3591 Address: rue du Biez Building year : 1979 Pre-retrofit Description 10 cm width concrete paving Floor Gable end walls Front wall Exterior render Thermal insulation : Walls Loft Wood framework Roof Windows House door Heating 5 cm polystyrene insulation under the floor Concrete slab 16 cm width shuttered concrete 14 cm reinforced phenolic foam Sprayed render on front and back walls and painted concrete on side walls 4 cm polystyrene + 1cm plaster on front and back walls / 8 +1 on side walls 7 cm glass wool with moisture barrier Industrial frame Concrete Tile PVC double glazed windows on metallic frame with rolling shutter box (external mounted box) Non insulated wood thickness 46 mm Passive stack Self-adjusting air inlets Individual gas boiler for space heating and hot water production Steel heating units Houses pre-retrofit

4 Post Retrofitting Description 10cm width concrete paving Floor Walls Wall masonry Exterior siding Thermal insulation : Walls Loft Base Wood framework Roof Windows House door Heating 5 cm polystyrene insulation under the floor Concrete slab 16 cm width shuttered concrete 14 cm reinforced phenolic foam 8 mm cement fiber clapboards Wood frame/metisse 20cm insulation/rain barrier/siding 30cm cellulose wadding with moisture barrier Roofmate 60+10cm Industrial frame Concrete Tile PVC Paziaud ventilated windows with rolling shutter box (hidden box). 43 mm insulated door Mechanical ventilation Individual gas boiler for space heating and hot water production Steel heating units Houses in 2014

5 Type 1 House Window and Doors Solar Photo Voltaic Bungalow, Masonry Cavity, 1 Bedroom checked and filled with blown fibre where defective. 60 mm phenolic render finished to resident's colour choice. Replaced timber front and rear doors with new upvc doors. Refurbish existing upvc window seals, gaskets, geometry sets and handles. Most existing combination boilers retained. AlertMe smart controller. Mechanical ventilation with heat recovery.

6 Type 1 House Window and Doors Solar Photo Voltaic Bungalow, Masonry Cavity, 1 Bedroom checked and filled with blown fibre where defective. 60 mm phenolic render finished to resident's colour choice. Replaced timber front and rear doors with new upvc doors. Refurbish existing upvc window seals, gaskets, geometry sets and handles. Most existing combination boilers retained. AlertMe smart controller. Mechanical ventilation with heat recovery.

7 Type 2 House Bungalow, Masonry Cavity, 1 Bedroom checked and filled with blown fibre where defective. Window and Doors Solar Photo Voltaic 60 mm phenolic render finished to resident's colour choice. Replaced timber front and rear doors with new upvc doors. Refurbish existing upvc window seals, gaskets, geometry sets and handles. Communal ground source (3 properties) and exhaust air heat pumps (3 properties) fitted to replace gas boilers. Heat pump controls only. Mechanical ventilation with heat recovery (most properties).

8 Type 3 House Window and Doors Solar Photo Voltaic Bungalow, Masonry Cavity, 1 Bedroom checked and filled with blown fibre where defective. 60 mm phenolic render finished to resident's colour choice. Replaced timber front doors with new upvc doors. Refurbish existing upvc window seals, gaskets, geometry sets and handles. Only one combination boiler replaced. Most have AlertMe, 1 property with Wattbox smart controller. Mechanical ventilation with heat recovery.

9 Type 4 House Window and Doors Solar Photo Voltaic Terraced House, Masonry Cavity 2 Bedrooms checked and filled with blown fibre where defective. 60 mm phenolic render finished to resident's colour choice. Most timber front and back doors replaced with new upvc doors. Refurbish existing upvc window seals, gaskets, geometry sets and handles. Most existing boilers upgraded to SEDBUK 'A' rated condensing boiler if Including TRVs with new boiler. Most have AlertMe, a couple with Wattbox smart controllers. Trickle vents mechanically vented kitchens and bathrooms. Not applicable 2.5kW Solar PV on south facing roofs including inverter and system controls.

10 Type 5 House Window and Doors Solar Photo Voltaic Terraced House, Masonry Cavity 3 Bedrooms checked and filled with blown fibre where defective. 60 mm phenolic render finished to resident's colour choice. Timber back doors replaced with new upvc doors. Refurbish existing upvc window seals, gaskets, geometry sets and handles some with replacement double glazed units. Most existing boilers upgraded to SEDBUK 'A' rated condensing boiler if Including TRVs with new boiler. Mix of AlertMe and Wattbox smart controllers. Trickle vents mechanically vented kitchens and bathrooms. Most have solar thermal collector panels on south facing roofs, including system controls and dual coil cylinder. One property has 2.5kW Solar PV on its south facing roof including inverter and system controls.

11 Type 6 House Window and Doors Solar Photo Voltaic Terraced House, Masonry Cavity 3 Bedrooms checked and filled with blown fibre where defective. 60 mm phenolic render finished to resident's colour choice. Most timber front and back doors and some side doors replaced with new upvc doors. Refurbish existing upvc window seals, gaskets, geometry sets and handles many with replacement double glazed units. Most existing boilers upgraded to SEDBUK 'A' rated condensing boiler if Including TRVs with new boiler. Most have AlertMe, three with Wattbox smart controllers. Trickle vents mechanically vented kitchens and bathrooms. About 50% of properties have solar thermal collector panels on south facing roofs, including system controls and dual coil cylinder. About 50% of properties have 2.5kW Solar PV on south facing roofs including inverter and system controls.

12 Type 7 House Window and Doors Solar Photo Voltaic Terraced House, Masonry Cavity 3 Bedrooms checked and filled with blown fibre where defective. 60 mm phenolic render finished to resident's colour choice. Timber front and back doors replaced with new upvc doors. Refurbish existing upvc window seals, gaskets, geometry sets and handles one with replacement double glazed units. Most existing boilers upgraded to SEDBUK 'A' rated condensing boiler if Including TRVs with new boiler. Mix of AlertMe and Wattbox smart controllers. Trickle vents mechanically vented kitchens and bathrooms. Solar thermal collector panels on south facing roofs, including system controls and dual coil cylinder.