PRASAR BHARATI (India s Public Service Broadcaster) OFFICE OF THE ADDL. DIRECTOR GENERAL (E)(EZ) ALL INDIA RADIO & TELEVISION, KOLKATA

Size: px
Start display at page:

Download "PRASAR BHARATI (India s Public Service Broadcaster) OFFICE OF THE ADDL. DIRECTOR GENERAL (E)(EZ) ALL INDIA RADIO & TELEVISION, KOLKATA"

Transcription

1 PRASAR BHARATI (India s Public Service Broadcaster) OFFICE OF THE ADDL. DIRECTOR GENERAL (E)(EZ) ALL INDIA RADIO & TELEVISION, KOLKATA Speed Post No. EZ-3(6)/IEBR/METP/Cooling Tower-Kolkata/ AIR Maintenance Wing, Akashvani Bhavan, 4th floor, Eden Gardens, Kolkata , Dated : Sub :- SITC of Cooling Tower at Akashvani Bhavan, All India Radio, Kolkata Sir, On behalf of the President of India, this office would like to invite your Quotation for stores mentioned in the enclosed form. The rate should be in figure as well as in words. 1. The quotation should be sent to this office along with description of stores, makers name specification as per requirement of this office, terms of payment, validity period separately in cover may be mentioned. The cover must be wax sealed. The cover containing copy of PAN nos., Tax clearance, Quoted prices, Sales tax,rebate etc. to be furnished in the proforma forwarded by this office so as to reach within 14=00 Hrs on or before On sealed cover the tenderers will give the following details super scribing on the cover:- a) Materials for which quotation are enclosed. b) Reference of letter or enquiry. c) Due date of opening of quotations. d) Name of address of tender. 2. The quotations will be opened in the office of the undersigned at 15=00 Hrs. on The quotations as submitted should remain open for acceptance for a period of 180 days from the date of opening them. 5. Quotation should strictly conform to the specification mentioned in the particular annexure. 6. Quotation should strictly comply with the enclosed terms & conditions for submission of quotations. 7. Details literatures, drawing, operation manuals etc. applicable for the items offered should be enclosed with quotation stated in para-2 above. 8. Estimated cost Rs. 4.5 Lac. A sum of Rs.9,000/- to be submitted towards E.M.D. 9. The Additional Director General (E)(EZ), AIR & TV, Kolkata reserves the right to reject any or all quotations without assigning any reasons. 10. The is to be completed within 60days from date of issue of L.O.I. 11. All D/Draft, B/G etc. should be issued in favour of PRASAR BHARATI, O/O ADDL. DIRECTOR GENERAL (E)(EZ), AIR & TV, KOLKATA. 12. Lowest Quoted firm should deposit 10% of the order value in the form of B/G or D/Draft as performance Guarantee before getting the order. This should be valid till the completion of warranty period & will be released thereafter. 13. Liquidated Demurrage :- Delay in delivery of materials due to fault on the part of supplier will attract per week to a maximum of 5% of the contract amount. Yours faithfully, (Arijit Dutta) Assistant Engineer

2 For Addl. Director Gen.(E)(EZ )

3 RATES SHOULD BE QUOTED IN FIRMS LETTER HEAD ALSO TENDER No. EZ-3(6)/IEBR/METP/Cooling Tower-Kolkata/ Dated : Date of opening : (1500Hrs.) LAST DATE OF RECEIVING OF QUOTATION AT THE OFFICE OF THE ADDL. DIRECTOR GENRAL(E)(EZ), AIR & TV, KOLKATA : (12Hrs.) SL. DESCRIPTION OF STORES QTY. RATE/UNIT TAXES TOTAL SUBMISSION OF INFORMATION NO. PRICE COST AS PER THE FORMAT IS MANDA- REMARKS TORY, OTHERWISE TENDER IS LIABLE TO BE REJECTED Supply of FRP Cooling Tower of 95Ton capacity for use in 3 x 40 Ton (2 in operation other being kept as stand-by) Make : Paharpur / Voltas Installation of Cooling Tower proper arrangement include civil work to be carried out by tendererer Condenser pipe line to connect the cooling tower with fixing of flange etc. Supply & fixing of butterfly valve suitable to existing pipe line of 3x40TR AC Plant Testing & commissioning on load (Estimated Cost : Rs.4,50,000/- & EMD is Rs.9,000/-) set As per Annexure- I TENDER S FULL ADDRESS SIGNATURE OF TENDERER VALIDITY PERIOD QUOTATION NO. & DATE KINDLY NOTE: WITHOUT THE FOLLOWING DETAILS OFFER WILL BE TREATED AS CANCELLED. 1. EX STOCK DELIVERY ;- YES /NO. 2. RATE OF SALES TAX WITH ST NO ST CLEARANCE CERTIFICATE TO BE ENCLOSED.

4 4. PAN NO.. 5. BANK A/C NO.. 6. EXCISE DUTY..7. OCTROI FREIGHT CHARGE, 9. OTHER TAXES OR DUTIES, IF ANY 10. SERVICE TAX, REGISTRATION NO. (IF APPLICABLE).. & 11. COPY OF TRADE LICENCE SHOULD BE ENCLOSED. INFORMATION TO NOTE 1. QUOTATION WHERIN PAYMENT INVOICE THROUGH BANK DOCUMENT IS INDICATED WILL BE STRAIGHTWAY REJECTED. NO ADVANCE PAYMENT IS ADMISSIBLE. 2. QUOTATION SHOULD STRICTLY COMPLY WITH THE ATTACHED TERM & CONDITION. 3. DETAILS CATALOGUE, PRICE LISTS OF THE ITEMS SHOULD BE ENCLOSED WHERE APPLICABLE. 4. FREE DELIVERY AT OFFICE GODOWN AT 35/1, RAJA MANINDRA ROAD, KOLKATA PLACE OF DELIVERY OTHER THAN GODOWN WILL BE CLEARLY MENTIONED IN THE ENQUIRY / PURCHASE ORDER. 6. IF THE ITEMS ARE UNDER DGS&D RATE CONTRACT, REFERENCE OF THE DGS&D RATE CONTRACT SHOULD INVARIABLY ADMITTED. 7. ST & IT CLEARANCE CERTIFICATE SHOULD BE ENCLOSED ALONG WITH THE QUOTATION. 8. PHOTO COPY OF CERTIFICATE OF THE LICENCE FOR ELECTRICAL WORK SHOULD BE SUBMITTED AGAINST ELECTRICAL WORK. 9. IN CASE OF CONTRACT WORK, WHETHER THE FIRM HAS OBTAINED LICENCE UNDER CONTRACT LABOUR ACT, IF YES, GIVE THE LICENCE NUMBER.

5 TECHNICAL DATA OF COOLING TOWER Annexure-I S I T C of FRP Cooling Tower of 95 Ton Capacity for 3 x 40 Ton (2Nos. in operational normally) Central AC Plant at Studio, Akashvani Bhavan, Kolkata 1.0 COOLING TOWERS 1.1 Scope : The scope of this section covers supply, installation, commissioning and testing of cooling tower conforming to these specifications also meeting the requirements of drawings and schedule of quantities. Necessary materials for connecting the existing set up with the cooling tower is within the scope to make the entire plant fully operational keeping the existing cooling tower as stand-by. 1.2 Type : The cooling tower shall be of approved make and type indicated in the Schedule of quantities. 1.3 Capacity : The cooling tower capacities shall be as indicated in the specification and/ or drawing/schedule of quantities. 1.4 FRP Induced draft Cooling Tower : Fiber reinforced plastic cooling towers shall be vertical type. Counter flow design, fiber reinforced plastic construction in square of bottle shope complete with casing, fills. Drift eliminator, fan, drive and fan motor and suitable for outdoor installation. 1.5 Casing : Casing shall be made out of FRP with smooth surfaces on both sides. It shall have sufficient structural strength to adequately withstand high wind velocities and vibration. The casing shall be installed in the fiberglass reinforced resin. The tower supporting structure shall be made out of hot dipped galvanized tubular frame. Air intake shall be all along the base circumference of cylindrical FRP casing so that tower can be installed quite independent of prevailing wind direction. A hot dip galvanized expanded metal mesh screen shall protect the air intake. Sufficient clearance between casing and water basin shall be provided to enable servicing and periodic cleaning. Filling shall be of corrosion proof rigid PVC film in honeycomb design and arranged to facilitate easy replacement. To minimize water drift losses, Multiple rotary drift eliminator shall be installed. Firms may visit AIR, Kolkata on any working day between Hrs.to assess the quantum of work before submission of quotation.

6 SELECTION Tower Type No. of Cells per tower No. of Tower Induced Draft Cross flow 1 (One) 1 (One) PERFORMANCE PER TOWER Capacity, USGPM 320 Hot Water Temperature, F 97.5 Cold Water Temperature, F 90 Design Wet Bulb Temperature, F 83 PHYSICAL DETAILS PER TOWER Tower Overall approx. ( L x W x H ) mm 2030 x 1905 x 2403 Pumping Head, m WC from C.W. Basin Support Level Shipping Weight, Kg 454 Operating Weight, Kg 1,256 MECHANICAL EQUIPMENT Fan : Diameter, (M) 48 (1.219) Type H 3 6 No. of Fans One per Tower Fan Speed, RPM 683 Drive Belt Drive MOTOR Power Rating, HP (KW) 5 (3.7) Current Characteristics 415 ± 10% / 3 / 50Hz ± 5% Efficiency Class EFF2 MATERIALS FOR CONSTRUCTION Casing Louvers Target Nozzles Fill Bolts Fan Guard Fan Blade Fan of Cylinder Basin FRP PVC, Integral with Fill Polypropylene PVC Galvanized Steel Galvanized Steel Cast Aluminium Alloy FRP FRP