Panel / Trim /Accessories. Corporate Office 1500 Hamilton Rd. Bossier City, LA

Size: px
Start display at page:

Download "Panel / Trim /Accessories. Corporate Office 1500 Hamilton Rd. Bossier City, LA"

Transcription

1 Panel / Trim /Accessories Corporate Office 1500 Hamilton Rd. Bossier City, LA

2 MULTI-RIB/R-PANEL Multi-Rib Multi-Rib Roofs &Walls 1 ( With Purlin Bearing Leg ) 36 Cover Width R-Panel 1.25 R-Panel Roofs & Walls ( With Purlin Bearing Leg ) 36 Cover Width Multi-Rib Walls Only ( Without Purlin Bearing Leg ) Cover Width R-Panel Walls Only ( Without Purlin Bearing Leg ) 36 Cover Width Multi-Rib and R-Panel Load Tables and Section Properties Load tables and section properties for Multi-Rib and R-Panel can be found in the download section at: Please contact the McElroy Technical Service Department at for additional information. Multi-Rib and R-Panel Notes: - Standard Panels: - 26 gauge Galvalume substrate with Kynar 500 (PVDF) coating or Silicone Modified Polyester (SMP) coating. - Minimum Slope: - 1:12 minimum slope with sidelap tape sealant. - Multi-Rib and R-Panel are also available in 24 gauge Galvalume substrate with Kynar 500 (PVDF) coating gauge Multi-Rib and R-Panel for roofs and walls with purlin bearing leg are manufactured out of grade 80 material and 24 gauge Multi-Rib and R-Panel for walls only with non purlin bearing leg are manufactured out of grade 50 material. - Standard minimum length is 3 and standard maximum length is Additional fees may apply for panel lengths under 3 and over Standard trim is 26 gauge. - Oil canning is inherent in all metal panels and is not a cause for panel rejection. - Please contact a McElroy Representative for specific pricing, lead times, special colors or gauges that may not be on a McElroy Metal color chart. - Contents in this manual are subject to change without notice. To confirm this book is the most current copy, please visit McElroy Metal s website at 1

3 MULTI-COR/M-COR Multi-Cor M-Cor 2.67 Multi-Cor Panel 2.67 M-Cor Panel Cover Width for Roofing and Siding Cover Width for Roofing and Siding Multi-Cor and M-Cor Load Tables and Section Properties Load tables and section properties for Multi-Cor and M-Cor can be found in the download section at: Please contact the McElroy Technical Service Department at for additional information. 2 Multi-Cor and M-Cor Notes: - Multi-Cor Standard Panels: - 26 gauge grade 80 Galvalume with Kynar 500 (PVDF) coating for walls and roofs gauge grade 50 Galvalume with Kynar 500 (PVDF) coating for walls only. - Please inquire for 22 and 24 gauge panels. - M-Cor Standard Panels - 24, 26, and 29 gauge Galvalume with Kynar 500 (PVDF) coating for walls and roofs. - Minimum Slope: - Multi-Cor and M-Cor: 1:12. Tape sealant required on all slopes. - Multi-Cor and M-Cor panels are also available with Silicone Modified Polyester (SMP) coatings. Please inquire. - Standard minimum length is 3 and standard maximum length is Additional fees may apply for panel lengths under 3 and over Standard trim is 26 gauge. - Oil canning is inherent in all metal panels and is not a cause for panel rejection. - Please contact a McElroy Representative for specific pricing, lead times, special colors or gauges that may not be on a McElroy Metal color chart. - Contents in this manual are subject to change without notice. To confirm this book is the most current copy, please visit McElroy Metal s website at

4 U-PANEL U-PANEL PURLIN BEARING PROFILE 6 (typ.) Cover Width U-Panel U-PANEL NON- PURLIN BEARING PROFILE Master Coil Width: 4 U-PANEL NON- PURLIN BEARING PROFILE 6 (typ.) 6 (typ.) Cover Width 36 Cover Width Master Coil Width: 40 7/8 (29 GA Only) Master Coil Width: 41 9/16 U-Panel Load Tables and Section Properties Load tables and section properties for U-Panel can be found online at Please contact the McElroy Technical Service Department at for additional information. Notes: - Standard Panels: - 26 gauge Galvalume substrate with Kynar 500 (PVDF) coating or Silicone Modified Polyester (SMP) coating gauge Galvalume substrate with Kynar 500 (PVDF) coating gauge Galvalume substrate with Kynar 500 (PVDF) coating or Silicone Modified Polyester (SMP) coating. - U-Panel with purlin bearing leg is run out of grade 80 material. - Minimum Slope: - 2:12 minimum roof slope without sealant tape. - Standard minimum length is 3 and standard maximum length is Additional fees may apply for panel lengths under 3 and over Standard trim is 26 gauge. - Oil canning is inherent in all metal panels and is not cause for panel rejection. - Please contact a McElroy representative for specific pricing, lead times and special colors or gauges that may not be on a McElroy Metal color chart. - Contents in this manual are subject to change without notice. To confirm this book is the most current copy, please visit McElroy Metal s website at 3

5 MULTI-V/MINI-RIB Multi-V Mini-Rib 1 (Nom.) Multi-V Panel Mini-Rib Panel / Cover Width 36 Cover Width Multi-V and Mini-Rib Load Tables and Section Properties Load tables and section properties for Multi-V and Mini-Rib can be found in the download section at: Please contact the McElroy Technical Service Department at for additional information. Multi-V and Mini-Rib Notes: - Standard Panels: - 26 gauge Galvalume substrate with Kynar 500 (PVDF) coating or Silicone Modified Polyester (SMP) coating. - Multi-V and Mini-Rib are also available in 24 gauge Galvalume substrate with Kynar 500 (PVDF) coating. - Mini-Rib is also available in 29 gauge Galvalume substrate with Kynar 500 (PVDF) coating or Silicone Modified Polyester (SMP) coating. - Standard minimum length is 3 and standard maximum length is Additional fees may apply for panel lengths under 3 and over Standard trim is 26 gauge. - Multi-V and Mini-Rib panels are to be used as wall panels only. - Oil canning is inherent in all metal panels and is not a cause for panel rejection. - Please contact a McElroy Representative for specific pricing, lead times, special colors or gauges that may not be on a McElroy Metal color chart. - Contents in this manual are subject to change without notice. To confirm this book is the most current copy, please visit McElroy Metal s website at 4

6 TRIM Simple Base Trim ITBD 2 3/ MULTI-RIB/R-PANEL 1 3/ 3/ Base Trim ITBT 1 3/ 2 5/8 Zee Flashing ITZF 1 3/ 1 1/ 2 5/8 Masonry Wainscoat ITMW 4 1/ Outside Corner ITOC 1 3/ Color Side Inside Corner ITIC 1 3/ 1 3/ / 1 3/ Outside Angle Trim ITOA Inside Angle Trim ITIA Jamb Trim ITJT 2 1/ 1/ 1 1/ Head Trim ITHT Mini Jamb / Header Cover ITMHJ Jamb / Head Cover Trim ITHJ 2 1/ 2 7/16 1 1/ /8 Eave Trim ITET 1 Sculptured Eave Trim ITSE 3 3/8 1 Rake Trim ITRT 1 3/ 6 1/ 1/ 2 1/ Rake Tie-In Trim ITEW 2 1/ specify roof pitch 5 1/ 1 3/ Rake Closure IT-RT 6 3/ Color Side Up High Side Eave Trim ITHS 8 3/

7 TRIM High Side Tie-In Trim ITSW 2 1/ MULTI-RIB/R-PANEL 1 Ridge Cap ITRC 11 1/ 11 1/ 1 Multi-Rib Formed Ridge Cap MRC 1 6 1/ 15 or or R-Panel Formed Ridge Cap RRC 1 Fixed Peak Box (Additional Roof Pitch Available) IT-PBF Variable Peak Box IT-PBV Field cut as required for pitch 2 2 Field bend 15 or or /8 1-8 Field cut as required for pitch Outside Corner Box for Standard Gutter (Right Hand Shown Left Hand Opposite) IT-OCB Gutter Corner Box For Sculptured Gutter (Right Hand Shown Left Hand Opposite) ITGCB 3 1/ 6 1/ High Side Corner Box (Right Hand Shown Left Hand Opposite) ITHSCB 8 4 1/ 1/2:12 up to 2:12 roof slopes with standard gutter. 2:12 up to 4:12 roof slopes with sculptured gutter. Standard Gutter 1/2:12 to 2:12 Pitch ITSG 3/ 7/8 Snow guards required to prevent damage caused by sliding snow. 5 3/ Sculptured Gutter 2 to 4:12 Pitch ISSG 1 1/ Varies with Pitch Snow guards required to prevent damage caused by sliding snow. 3 1/ 1 Varies with Pitch 20 - Gutter Strap IT-GS 1 5/8 15/16 15/ Standard Gutter End Cap (Right Hand Shown Left Hand Opposite) ITSGEC 4 15/16 Sculptured Gutter End Cap (Right Hand Shown Left Hand Opposite) ISGEC 4 3/ Aluminum Downspout Outlet BBPOUT 4 3/8 Color Side Up 1 1/8 2 3/ Color Side Up 5 1/ 4 3/ 1 3/8 6 specify roof pitch 3 15/ /16

8 TRIM x Downspout Elbow A-Style BBPELA MULTI-RIB/R-PANEL 9.5 Downspout Strap BBPDSS Downspout x BBPDS Lock-Seam Downspout - Corner (Right Hand Corner Shown) Lock-Seam Downspout - Center Please specify left or right hand corner Lock-Seam Downspout Outlet - Standard 2 1/ Lock-Seam Downspout Strap Skylight Side Trim - UL90 (For Use with Multi-RIb Panels) 1 3/8 1 3/8 3 3/8 5 7/8 3 7/8 3 3/8 3 3/8 1/ 1 1/ Skylight Side Trim - UL90 (For Use with R-Panels) 4 1/ 1/ 1 5/8 1 3/8 1 1/8 TRIM Simple Base Trim CORSB MULTI-COR/M-COR Base Trim CORBT Masonry Wainscoat CORMW 4 1/ 7 specify roof pitch 3/ 1 1/ /

9 TRIM Outside Angle Trim COROA MULTI-COR/M-COR Jamb Trim CORJT Head Trim CORHT 2 1/ 1/ 3/ 2 3/ 7/8 Jamb / Head Cover Trim ITHJ Eave Trim CORET 1 Rake Trim CORRT 5 2 7/16 8 1/8 1/ 4 3/8 5/8 Rake-Tie-In COREW High Side Eave Trim CORHS 1 High Side Tie In Trim CORSW 1 2 5/8 4 5/8 2 1/ 4 3/ 3 7/8 5/8 6 1/ Ridge Cap CORRF 11 1/ 11 1/ Downspout x BBPDS 1 Gutter CORGT 5 4 1/ 1 1 1/ 20 - Gutter Strap COR-GS Gutter End Cap CORGEC 4 15/16 4 7/8 1 7/16 x Downspout Elbow A-Style BBPELA 3 7/8 14 Aluminum Downspout Outlet BBPOUT 4 3/ /8 Downspout Strap BBPDSS 8 specify roof pitch 8.5

10 U-PANEL TRIM Simple Base Trim U-SB Base Trim U-BT Zee Flashing U-ZF 1 3/ 3/ 1 1/ Masonry Wainscoat U-MW 4 1/ Outside Corner U-OC 1 1/16 3 3/16 1 1/16 Inside Corner U-IC 3/ 5 3/ 1 1/16 1 1/16 1/ 3 3/16 1 1/8 3/ Outside Angle Trim U-OA Inside Angle Trim U-IA Jamb Trim U-JT 2 1/ 1/ 3/ 7/8 Color Side Head Trim U-HT Eave Trim U-EF 1 Sculptured Eave Trim U-SE 3 13/ / 2 11/16 1/ Color Side 1/ 9 Rake Trim U-RT 1 1/16 specify roof pitch 5 1/ High Side Eave Flashing U-HS 8 3/ 1 Rake Tie-In Trim U-EW 2 1/ 2 7/16 High Side Tie-In Trim U-EW 2 1/ 1 1/16 H Rake Closure U-RC 6 3/ Up 1 Ridge Cap U-RC 11 1/ 11 1/ 6 1/ 1 Indicates an open hem - All other hems are closed.

11 U-PANEL TRIM Formed Ridge Cap URC 1 Fixed Peak Box (Additional Roof Pitch Available) U-PB Outside Corner Box for Standard Gutter (Right Hand Shown Left Hand Opposite) U-OCB /8 36 Gutter Corner Box For Sculptured Gutter (Right Hand Shown Left Hand Opposite) U-GCB 6 1/ 3 1/ High Side Corner Box (Right Hand Shown Left Hand Opposite) U-HSC Gutter U-GT 1/2:12 up to 2:12 roof slopes with standard gutter. 5/8 7/8 5 7/8 4 1/ 2:12 up to 4:12 roof slopes with sculptured gutter. Sculptured Gutter U-SG 7/ / 6 7/8 Gutter End Cap UGEC5 4 7/8 4 13/16 Color Side Up 1 5/8 3 7/16 Gutter End Cap Sculptured UGECT 4 9/16 6 Color Side Up 3 5/ / /16 3 7/16 Gutter Strap U-GS Aluminium Downspout Outlet BBPOUT Downspout BBPDS 1 1/8 4 3/ 15/16 15/16 1 3/8 Downspout Strap BBPDSS 0-6 A-Style Elbow BBPELA specify roof pitch 8.5 H Indicates an open hem - All other hems are closed.

12 MULTI-V TRIM Simple Base Trim ITBD Base Trim ITBT 1 3/ Masonry Wainscoat ITMW 4 1/ 2 3/ 3/ 2 5/8 1 3/ 2 5/ / Multi-V Outside Corner 1 3/ 5 1/ Outside Angle Trim ITOA Inside Angle Trim ITIA 1 3/ 5 1/ Jamb Trim ITJT 2 1/ 1 1/ 1/ Head Trim ITHT 2 1/ Jamb / Head Cover Trim ITHJ 2 7/16 1 1/ 8 1/8 MINI-RIB TRIM Inside Angle Trim ITIA Outside Angle Trim ITOA Notes: 11 specify roof pitch

13 MULTI-RIB / R-PANEL / MULTI-COR M-COR / U-PANEL / MULTI-V / MINI-RIB ACCESSORIES 1/4-14 x 1 1/ TEK2 ZAC Self-Driller (Part # Varies by Color) 1/4-14 x 7/8 LAPTEK ZAC Self-Driller (Part # Varies by Color) #14 x 1 1/ Type AB ZAC (Part # Varies by Color) #12-14 x 1 1/ TEK2 HWH w/washer Self-Driller (Part # Varies by Color) 1/4-14 x 7/8 LAPTEK HWH w/washer Self-Driller (Part # Varies by Color) #9-15 Type A Woodgrip W/Washer (Part # varies by color) 1 1/ 2 1/ #10-15 Woodgrip HILO ZAC (Part # varies by Color) 43D Pop rivets (Part # varies by color) Touch-Up Paint Pen (Part # Varies by Color) Roll Tape Sealant 3/3 X X 45 Item #: Roll Tape Sealant 1/8 x x 30 Item #: White Urethane Sealant Item #: Titebond Caulk Sealant (Part # varies by color) Butyl Tube Sealant Item #: Multi-Rib Outside Closure With Adhesive: Without Adhesive: R-Panel Outside Closure With Adhesive: Without Adhesive: Multi-V Outside Closure Multi-Rib Inside Closure With Adhesive: Without Adhesive: R-Panel Inside Closure With Adhesive: Without Adhesive: Multi-V Inside Closure Mini-RIb Closure Multi-Cor Closure M-Cor Closure Multi-Rib Fiberglass Panel Available in Clear, White and Opal Images not drawn to scale.

14 MULTI-RIB / R-PANEL / MULTI-COR M-COR / U-PANEL / MULTI-V / MINI-RIB ACCESSORIES R-Panel Fiberglass Panel Item #: U-Panel Fiberglass Panel 37 3/8 X 12 Item #: Sunsky Clear Polycarbonate Panel (For MULTI-RIB) Available in Clear and White Sunsky Clear Polycarbonate Panel (For R-PANEL) Available in Clear and White 11 Not inventoried at all locations Not inventoried at all locations Notes: 13 Images not drawn to scale.

15

16 5215 Leo St. Alexandria, LA Hamilton Rd. Bossier City, LA Yadkin Chesapeake, VA Meadowbrook Rd. Clinton, IL Highway 59 Diamond, MO N. Valley Dell Dr. Fenton, MO Lovejoy Road Ft. Walton Beach, FL Lincoln Court Garland, TX Aldine Bender Road Houston, TX E. 59th Street Indianapolis, IN U,S, Hwy. 60 W. Lewisport, KY Terminal Dr. McFarland, WI Cave Road Nashville, TN Hwy. 70 E. North Little Rock, AR North Bierdeman Rd. Pearl, MS rd Street Sacramento, CA Dean Forest Rd. Savannah, GA Oakley Industrial Blvd. Union City, GA Silstar Rd. West Columbia, SC McGhee Rd. Winchester, VA MM424-A Rev