MANAGEMENT ASBESTOS SURVEY REPORT

Size: px
Start display at page:

Download "MANAGEMENT ASBESTOS SURVEY REPORT"

Transcription

1 Elstree Film Studios, Shenley Rd, Borehamwood, WD6 GJ M H Goldsmith & Sons Ltd Survey No /934 Survey Date / - //5 MANAGEMENT ASBESTOS SURVEY REPORT Presented by a Station Rd, Knebworth, Herts, Tel: tony@goldsmithasbestos.co.uk

2 Elstree Film Studios, Shenley Rd, Borehamwood, WD6 GJ M H Goldsmith & Sons Ltd Survey No /934 Survey Date / - //5 Contents EXECUTIVE SUMMARY... 3 Identified ACM s and Recommendations... 3 JOHN MAXWELL... 3 ANDREW MITCHELL... 3 ANCILLARY BLOCK... 4 WORKSHOPS... 4 INTRODUCTION... 5 Surveying Company Details... 5 Instructing Party Details... 5 Site Address Details... 5 Survey Date... 5 Name... 5 Report Production... 5 Description of Premises... 6 Scope of Works... 6 Purpose, Aims and Objectives... 6 RISK ASSESSMENT FORMULAE... 7 SURVEY LIMITATIONS... BULK ANALYSIS REPORTS (Appendix A)... 3 SURVEY INSPECTION DATA (Appendix B)... 4 LOCATION DRAWINGS (Appendix C)... 5

3 Elstree Film Studios, Shenley Rd, Borehamwood, WD6 GJ M H Goldsmith & Sons Ltd Survey No /934 Survey Date / - //5 EXECUTIVE SUMMARY Identified ACM s and Recommendations JOHN MAXWELL Samples & are asbestos cement window sills running round the perimeter of the first floor on the John Maxwell building, these sills can be left in situ and managed under a sufficient management plan. Sample is an asbestos acoustic pad beneath the sink within the tea room, this material is very low grade and can be managed. ANDREW MITCHELL Asbestos sprayed insulation residue has been previously identified to structural beams in stages 7, 8 and 9, these are now cladded with MMMF insulation and modern fire line board, asbestos residue has been identified behind this boarding in a previous pipe penetration, no works should be carried out beyond the cladding due to risk of residue/debris being in situ. Sample is insulation board to either side of the double doors within corridor, this board is in good condition, sealed and can be managed. Sample 3 is an insulation board bulk head above room 6, this board is high level and out of reach, therefore this board can be labelled and managed. Sample 4 is an insulation board bulk head within corridor 4, this board is high level and out of reach, therefore this board can be labelled and managed. Sample 5 are ceiling tiles in the stairwell leading up to the plant rooms, these this area is not used much by staff or public and therefore can be left in situ and managed. Sample 6 is fuse carriers in the fuse box within the plant room, this fuse box is redundant and should be sealed shut or removed. Sample 7 is textile debris beneath ducting within the plant room, this area will require an environmental clean prior to any works being carried out in this area. Sample 8 is fuse carriers in the fuse box within the plant room, this fuse box is redundant and should be sealed shut or removed. Sample 9 are ceiling tiles at the top of the stairwell outside the plant rooms, these this area is not used much by staff or public and therefore can be left in situ and managed 3

4 Elstree Film Studios, Shenley Rd, Borehamwood, WD6 GJ M H Goldsmith & Sons Ltd Survey No /934 Survey Date / - //5 ENIGMA Asbestos pipe insulation has been located at high level in units 4 and 5, this material runs into unit 6 but a new ceiling has been installed and no access could be gained above the plasterboard ceiling. Samples 38 & 4 have identified asbestos pipe insulation debris to the walls within the plant room, this has been left from previous asbestos removal works. Above this room is a loft space where pipework runs through, No access could be gained into this loft space due to stored items, but it is strongly presumed that asbestos debris is present within the loft. ANCILLARY BLOCK Duct gaskets have been identified to contain asbestos within ALL the plant rooms, not all gaskets have been sampled but should be presumed to contain asbestos. The underground carpark previously had sprayed asbestos coating to the ceiling, this could not be accessed without removing some of the new Non asbestos fire proof coating. Signs have been erected informing trades that debris is still in situ and no works should be carried out in these areas without a specific risk assessment. Insulation debris has been found within the risers of this block, these risers have been sealed off and cause no potential risk, no maintenance works should be carried out within these risers until asbestos removal works have been carried out. WORKSHOPS These 95 s buildings are identified as having high level asbestos cement roof sheets, guttering and vertical cladding, these bonded materials are out of reach and pose a low risk of fibre release, can be left in situ and easily managed. NOTES None of the live wire boxes have been accessed anywhere throughout all the buildings due to safety reasons. All fuse boxes should be presumed to contain asbestos until proven otherwise. No fire doors were checked intrusively as this would ruin the integrity of the doors fire rating. No access has been gained above plasterboard ceilings unless a service hatch was present. No floor voids were accessed as this would require specialised lifting equipment. Limited access within rooms 4, 5, and 6 Enigma building due to items stored within the rooms. No access beyond sealed plasterboard ceiling into the ceiling voids, in corridor 4, room 4A, room 4B and room 5 within the Andrew Mitchell building 4

5 Elstree Film Studios, Shenley Rd, Borehamwood, WD6 GJ M H Goldsmith & Sons Ltd Survey No /934 Survey Date / - //5 INTRODUCTION Surveying Company Details M H Goldsmith & Sons Ltd, a Station Road, Knebworth, Herts, Tel: tony@goldsmithasbestos.co.uk Instructing Party Details Mr Paul Clarke C/o Elstree Film Studios Ltd, Shenley Road, Borehamwood, WD6 GJ Site Address Details Elstree Film Studios Ltd, Shenley Rd, Borehamwood, WD6 GJ Survey Date //5 - //5 Name - Lead Tony Goldsmith - Assistant Report Production Report Prepared By: Position in Company Asbestos Operations manager Signature: Date: //5 5

6 Elstree Film Studios, Shenley Rd, Borehamwood, WD6 GJ M H Goldsmith & Sons Ltd Survey No /934 Survey Date / - //5 Description of Premises Numerous buildings of varied age, construction and use within a fully operational complex used as film studios. Scope of Works To carry out an asbestos management survey to all buildings, workshops, offices and out houses throughout the site instructed by the client. Purpose, Aims and Objectives This asbestos management survey was requested to ensure that any previously unidentified accessible asbestos bearing materials were located to prevent accidental exposure of employees, maintenance staff and the general public alike. All reasonably practicable accessible areas were inspected during the course of this survey. The appropriate level of survey was agreed as a: Management Asbestos survey with samples taken of any suspect ACM s to found. All samples taken, will be analysed by a UKAS accredited laboratory for definitive identification and proved to be either asbestos bearing or definitely not asbestos bearing. The purpose of the survey report is to help assist the client in complying with all current and relevant HSE Laws, ie. The Health & Safety at Work Act 974, The Control of Asbestos Regulations (CAR Revision ), The Construction (Design and Management) Regulations 7 using HSG64 (nd Edition). The objective of this survey report is to enable the client (in addition to the aforementioned) to confirm the location, type, condition and extent of asbestos containing materials within the property surveyed in compliance with the scope of the clients instructions received. Once the Asbestos Survey or sampling has been conducted and this Asbestos Management Survey report issued, further advices can be given to advise the client on how to safely manage and monitor or remove/repair/encapsulate any known ACM s by a Reputable removal company assisting them in undertaking a Priority Assessment which will help implement a Asbestos Management Plan to keep this Asbestos Management Survey relevant and up to date. 6

7 Elstree Film Studios, Shenley Rd, Borehamwood, WD6 GJ M H Goldsmith & Sons Ltd Survey No /934 Survey Date / - //5 RISK ASSESSMENT FORMULAE Guidance Note HSG64 prescribes the formula by which the relative risk of each asbestos incidence can be assessed. A total risk score of between and is calculated using four categories that are evaluated by the surveyor against given values. The criteria and the respective values are as follows: PRODUCT TYPE pt Asbestos reinforced composites such as plastics, resins, mastic, felt, vinyl tiles, paints and decorative finishes, asbestos cement products Asbestos insulating board, mill boards, other low density insulation boards, asbestos textiles, gaskets, ropes, paper etc 3 Thermal insulation, sprayed asbestos, loose asbestos, mattresses and packing EXTENT OF DAMAGE pt Good condition, no visible damage Low damage, a few scratches or surface marks, broken edges of boards, tiles etc Medium damage, significant breakage of materials or several small areas where fibres are exposed 3 High damage or delimitation of materials, sprays and thermal insulation, visible asbestos debris SURFACE TREATMENT pt Composite products such as plastics, resins and tiles Enclosed sprays and lagging, boards with exposed surface painted or sealed, asbestos cement products Sealed boards or sealed lagging sprays 3 Unsealed boards or unsealed lagging and sprays 7

8 Elstree Film Studios, Shenley Rd, Borehamwood, WD6 GJ M H Goldsmith & Sons Ltd Survey No /934 Survey Date / - //5 ASBESTOS TYPE pt Chrysotile (white) asbestos Amosite (brown) asbestos 3 Crocidolite (blue) asbestos The algorithms shown against each situation are added together to give a total risk score, for the purpose of brevity, the register we have prepared contains only the total risk score rather than the component scores. The total score for each situation can be broadly classified using the following bands: Up to 4 Points Very Low Risk 5-6 Points Low Risk 7 9 Points Medium Risk Points High Risk It is likely that high risk items will be highlighted in the report text and that some immediate action will be required. Other items may also be considered for attention where the discretion of the surveyor suggests this would be expedient. 8

9 Elstree Film Studios, Shenley Rd, Borehamwood, WD6 GJ M H Goldsmith & Sons Ltd Survey No /934 Survey Date / - //5 Significance of the algorithm score The algorithm is a numerical way of taking into account many influencing factors, giving each factor considered a score. These scores are totalled to give the material assessment score. Each of the parameters are scored are added to give a total score between and : Materials with scores of or more should be regarded as high risk with a significant potential to release fibres if disturbed; Those with a score between 7 & 9 are regarded as medium risk; Materials with a score between 5 & 6 are low risk; and s of 4 or less are very low risk. The material assessment identifies the high risk materials, that is those which will most readily release airborne fibres if disturbed. It does not automatically follow that those materials assigned the highest score in the material assessment will be the materials that should be given priority for remedial action. Management priority must be determined by carrying out risk assessment which will take into account factors such as Maintenance activity Occupant activity Likelihood of Disturbance Human exposure potential Recommandations for priority of management of materials are based on level of risk. M H Goldsmith & Sons advise their clients to carry out their own priority risk assessments in accordance with HSG7 & HSG 64, This assessment can be carried out by using the parameters from the scoring system below, in this instance a priority assessment has been carried out on each sample and recorded on the sample identification sheet. Assessment Factor variable Normal occupant activity Main type of activity in area 3 Rare disturbance activity (eg little used store room) Low disturbance activites (eg office type activity) Periodic disturbance (eg industrial or vehicular activity which may contact ACMs High levels of disturbance, (eg fire door with asbestos insulating board sheet in constant use) Secondary activities for area Likelihood of Disturbance As above As above Location 3 Outdoors Large rooms or well-ventilated areas Rooms upto m Confined space 9

10 Elstree Film Studios, Shenley Rd, Borehamwood, WD6 GJ M H Goldsmith & Sons Ltd Survey No /934 Survey Date / - //5 ibility Extent/amount Human Exposure Potential Number of occupants Frequency of use of area Average time area is in use Maintenance activity Type of maintenance activity Frequency of maintenance activity Usually inaccessible or unlikely to be disturbed Occasionally likely to be disturbed Easily disturbed Routinely disturbed Small amounts or items (eg strings, gaskets) =<m or =<m pipe run =<m to =<5m or =<m to =<5m pipe run =<5m or =<5m pipe run None to 3 4 to > Infrequent Monthly Weekly Daily < hour > hour to <3 hours >3 to <6 hours >6 hours Minor disturbance Low disturbance Medium disturbance High level disturbance ACM unlikely to be disturbed for maintenance =< per year > per year > per month

11 Elstree Film Studios, Shenley Rd, Borehamwood, WD6 GJ M H Goldsmith & Sons Ltd Survey No /934 Survey Date / - //5 SURVEY LIMITATIONS Every effort has been made to identify all asbestos materials so far as was reasonably practical to do so within the scope of the survey and the attached report. Methods used to carry out the survey were agreed with the client prior to any works being commenced. Survey techniques used involves trained and experienced surveyors using the combined approach with regard to visual examination and necessary bulk sampling. It is always possible after a survey that asbestos based materials of one sort or another may remain in the property or area covered by that survey, this could be due to various reasons: Asbestos materials existing within areas not specifically covered by this report are therefore outside the scope of the survey. Materials may be hidden or obscured by other items or cover finishes i.e. paint, over boarding, disguising etc. Where this is the case then its detection will be impaired. M H Golsmith & Sons Ltd cannot be held liable for asbestos containing materials that may well be hidden as part of the structure to a building and not visible until the structure is dismantled at a later date. Debris from previous asbestos removal projects may well be present in some areas; general asbestos debris does not form part of this survey however all good intentions are made for its discovery. Where an area has been previously stripped of asbestos i.e. plant rooms, ducts etc. and new coverings added, it must be pointed out that asbestos removal techniques have improved steadily over the years since its introduction. Most notably would be the Control of Asbestos at Work Regulations (987) laying down certain enforceable guidelines. Asbestos removal prior to this regulation would not be of today s standard and therefore debris may be present below new coverings. This survey will detail all areas accessed and all samples taken, where an area is not covered by this survey it will be due to No for one reason or another i.e. working operatives, sensitive location or just simply no access. It may have been necessary for the limits of the surveyor s authority to be confirmed prior to the survey. for the survey may be restricted for many reasons beyond our control such as height, inconvenience to others, immovable obstacles or confined space. Where electrical equipment is present and presumed in the way of the survey no access will be attempted until proof of its safe state is given. Our operatives have a duty of care under the Health and Safety at Work act (974) for both themselves and others. In the building where asbestos has been located and it is clear that not all areas have been investigated, any material that is found to be suspicious and not detailed as part of the survey should be treated with caution and sampled accordingly. Certain materials contain asbestos to varying degrees and some may be less densely contaminated at certain locations (Artex for example). Where this is the case the sample taken may not be representative of the whole product throughout.

12 Elstree Film Studios, Shenley Rd, Borehamwood, WD6 GJ M H Goldsmith & Sons Ltd Survey No /934 Survey Date / - //5 Where a survey is carried out under the guidance of the owner of the property or his representative, then the survey will be as per his instructions and guidance at that time. M H Goldsmith Ltd cannot accept any liability for loss, injury, damage or penalty issues due to errors or omissions within this report. M H Goldsmith Ltd cannot be held responsible for any damage caused as part of this survey carried out on your behalf. Due to the nature and necessity of sampling for asbestos some danger is unavoidable and will be limited to just that necessary for the taking of the sample.

13 Elstree Film Studios, Shenley Rd, Borehamwood, WD6 GJ M H Goldsmith & Sons Ltd Survey No /934 Survey Date / - //5 BULK ANALYSIS REPORTS (Appendix A) 3

14 Airtech Analysis Ltd Asbestos Consultancy, Analysis, Monitoring Environmental Surveying, R.I.C.E Member Unit 6, Blenheim Court, Hurricane Way, 68 Wickford Business Park, Wickford, Essex, SS 8YT Tel: (4hrs) Facsimile: E mail: enquiries@airtechanalysisltd.com ASBESTOS BULK IDENTIFICATION CERTIFICATE Report No: BS/44985 Date of Issue: 9 th January 5 Issue No: 3 Client: A Class Asbestos Contractors Client Unit 5 Tuskite Business Park Pitsea Hall Lane Pitsea Essex SS6 4UH Client Order No: - Contact: A Class Asbestos Contractors Site: Studios Elstree Shenley Road Borehamwood Hertfordshire Date samples received: 6 th January 5 Date/s of Analysis Start: 7 th January 5 Number of samples received: 3 Finish: 7 th January 5 Methodology: Analysis of all samples has been carried out to determine the presence of asbestos using Polarised Light Microscopy and dispersion staining techniques. These in-house methods are UKAS accredited and in accordance with Airtech Analysis Ltd Quality control manual Appendix XIV and HSE document HSG48 Appendix : Asbestos in bulk materials: Sampling and Identification by Polarised Light Microscopy (PLM) Disclaimers: All samples received from the client are analysed and data recorded as received. Airtech Analysis Ltd can take no responsibility for Inaccuracies, omissions, unrepresentative samples or discrepancies in samples and information received, material descriptions are the analysts opinion & fall outside our scope of accreditation. LABORATORY SAMPLE NO TEST RESULTS CLIENT SAMPLE NO SAMPLE LOCATION MATERIAL DESCRIPTION ASBESTOS TYPE/S IDENTIFIED CHRYSOTILE BS/44985/ John Maxwell, second floor, room 8, window sill Cement BS/44985/ John Maxwell, second floor, tea room, Bitumen CHRYSOTILE sink pad BS/44985/3 3 John Maxwell, second floor, tea room, Beige tile & bitumen N.A.D.I.S floor BS/44985/4 4 John Maxwell, second floor, plant room, Insulating board N.A.D.I.S next to access ladder BS/44985/5 5 John Maxwell, second floor, plant room, Insulating board N.A.D.I.S above lift shaft BS/44985/6 6 John Maxwell, second floor, plant room, Sprayed insulation N.A.D.I.S around steel beams BS/44985/7 7 John Maxwell, second floor, tank room, Sprayed insulation N.A.D.I.S above switch room around beams BS/44985/8 8 John Maxwell, second floor, switch Beige tile & bitumen N.A.D.I.S room, floor BS/44985/9 9 John Maxwell, second floor, corridor, Insulating board N.A.D.I.S ceiling void BS/44985/ John Maxwell, first floor, room 8, Cement CHRYSOTILE window sill BS/44985/ John Maxwell, first floor, tea room, sink Bitumen N.A.D.I.S pad BS/44985/ John Maxwell, first floor, tea room, floor Beige tile & bitumen N.A.D.I.S BS/44985/3 3 John Maxwell, first floor, mezz, internal fascia panel Insulating board N.A.D.I.S AA/LD/9- Directors: P J Abrey. T.M. Abrey, D Abrey, L Abrey Issue date:.. Reg Office: Unit 6, Blenheim Court, Hurricane Way, Wickford Business Park, SS 8YT. Company Reg No: 5689 Page of

15 LABORATORY SAMPLE NO Airtech Analysis Ltd Asbestos Consultancy, Analysis, Monitoring Environmental Surveying, R.I.C.E Member Unit 6, Blenheim Court, Hurricane Way, 68 Wickford Business Park, Wickford, Essex, SS 8YT Tel: (4hrs) Facsimile: E mail: enquiries@airtechanalysisltd.com CLIENT SAMPLE NO SAMPLE LOCATION MATERIAL DESCRIPTION ASBESTOS TYPE/S IDENTIFIED N.A.D.I.S BS/44985/4 4 John Maxwell, first floor, second sense, corridor, above window Insulating board BS/44985/5 5 John Maxwell, ground floor, workshop Sprayed insulation N.A.D.I.S B, beams BS/44985/6 6 John Maxwell, ground floor, stage 6, Sprayed insulation N.A.D.I.S store, around beam BS/44985/7 7 John Maxwell, ground floor, workshop Sprayed insulation N.A.D.I.S E, around beam BS/44985/8 8 White house, ground floor, windows Putty N.A.D.I.S BS/44985/9 9 Power house, ground floor, substation, floor void BS/44985/ Power house, transformer room, floor void BS/44985/ Andrew Mitchell, first floor, stairwell, ceiling BS/44985/ Andrew Mitchell, st floor, corridor, infill panels, either side of doors BS/44985/3 3 Andrew Mitchell, first floor, corridor, above room 6, bulkhead BS/44985/4 4 Andrew Mitchell, first floor, corridor 4, above cupboards, bulkhead BS/44985/5 5 Andrew Mitchell, first floor, staircase to plant room, ceiling tile BS/44985/6 6 Andrew Mitchell, second floor, duct, vent, distribution board, flue carrier BS/44985/7 7 Andrew Mitchell, second floor, duct vent, under ducting BS/44985/8 8 Andrew Mitchell, second floor, boiler room, fuse carrier BS/44985/9 9 Andrew Mitchell, second floor, landing, ceiling BS/44985/3 3 Andrew Mitchell, second floor, kitchen, sink pad Key: N.A.D.I.S = No asbestos detected in sample Debris Debris Insulating board Insulating board Insulating board Insulating board Insulating board Textile Textile Textile Insulating board Bitumen N.A.D.I.S N.A.D.I.S N.A.D.I.S AMOSITE CHRYSOTILE AMOSITE CHRYSOTILE AMOSITE CHRYSOTILE AMOSITE CHRYSOTILE CHRYSOTILE CHRYSOTILE CHRYSOTILE AMOSITE CHRYSOTILE N.A.D.I.S Samples analysed by: D. O Flaherty Signature Certificate issued by: Position: G. Freeman Consultancy Manager Signature AA/LD/9- Directors: P J Abrey. T.M. Abrey, D Abrey, L Abrey Issue date:.. Reg Office: Unit 6, Blenheim Court, Hurricane Way, Wickford Business Park, SS 8YT. Company Reg No: 5689 Page of

16 Airtech Analysis Ltd Asbestos Consultancy, Analysis, Monitoring Environmental Surveying, R.I.C.E Member Unit 6, Blenheim Court, Hurricane Way, 68 Wickford Business Park, Wickford, Essex, SS 8YT Tel: (4hrs) Facsimile: E mail: enquiries@airtechanalysisltd.com ASBESTOS BULK IDENTIFICATION CERTIFICATE Report No: BS/9 Date of Issue: th February 5 Issue No: 3 Client: A Class Asbestos Contractors Client Unit 5 Tuskite Business Park Pitsea Hall Lane Pitsea Essex SS6 4UH Client Order No: - Contact: A Class Asbestos Contractors Site: Elstree Film Studios Shenley Road Borehamwood WD6 SG Date samples received: 3 rd February 5 Date/s of Analysis Start: 4 th February 5 Number of samples received: 67 Finish: 4 th February 5 Methodology: Analysis of all samples has been carried out to determine the presence of asbestos using Polarised Light Microscopy and dispersion staining techniques. These in-house methods are UKAS accredited and in accordance with Airtech Analysis Ltd Quality control manual Appendix XIV and HSE document HSG48 Appendix : Asbestos in bulk materials: Sampling and Identification by Polarised Light Microscopy (PLM) Disclaimers: All samples received from the client are analysed and data recorded as received. Airtech Analysis Ltd can take no responsibility for Inaccuracies, omissions, unrepresentative samples or discrepancies in samples and information received, material descriptions are the analysts opinion & fall outside our scope of accreditation. TEST RESULTS LABORATORY SAMPLE NO CLIENT SAMPLE NO SAMPLE LOCATION MATERIAL DESCRIPTION ASBESTOS TYPE/S IDENTIFIED BS/9/ 3 Andrew Mitchell, ground floor, staircase Stair nosing N.A.D.I.S BS/9/ 3 Enigma, first floor, room 7a Wallboard N.A.D.I.S BS/9/3 33 Enigma, first floor, corridor, outside Wallboard N.A.D.I.S room 5 BS/9/4 34 Enigma, first floor, room 3B, lining to Lining N.A.D.I.S loading bay doors BS/9/5 35 Enigma, room 5, wallboard Wallboard N.A.D.I.S BS/9/6 36 Enigma, unit 4, pipe insulation, high level Thermal insulation AMOSITE CHRYSOTILE BS/9/7 37 Enigma, media powerhouse, outside lift, Thermal insulation N.A.D.I.S pipe insulation BS/9/8 38 Enigma, ground floor, unit 7, plant room, walls Insulation debris AMOSITE CHRYSOTILE BS/9/9 39 Enigma, ground floor, unit 7, plant room, Textile CHRYSOTILE fuse box, rope flash bands BS/9/ 4 Enigma, ground floor, unit 7, plant room, Textile N.A.D.I.S fuse box, paper flash bands BS/9/ 4 Enigma, ground floor, unit 7, plant room, wall Insulation debris AMOSITE CHRYSOTILE BS/9/ 4 Enigma, ground floor, unit 5, electric cupboard, walls & ceiling Insulating board AMOSITE CHRYSOTILE BS/9/3 43 Enigma, ground floor, unit 5, mezzanine, Bitumen N.A.D.I.S sink pad BS/9/4 44 Workshop, external roof, cement roof Cement CHRYSOTILE AA/LD/9- Directors: P J Abrey. T.M. Abrey, D Abrey, L Abrey Issue date:.. Reg Office: Unit 6, Blenheim Court, Hurricane Way, Wickford Business Park, SS 8YT. Company Reg No: 5689 Page of 4

17 Airtech Analysis Ltd Asbestos Consultancy, Analysis, Monitoring Environmental Surveying, R.I.C.E Member Unit 6, Blenheim Court, Hurricane Way, 68 Wickford Business Park, Wickford, Essex, SS 8YT Tel: (4hrs) Facsimile: E mail: enquiries@airtechanalysisltd.com LABORATORY SAMPLE NO CLIENT SAMPLE NO SAMPLE LOCATION MATERIAL DESCRIPTION ASBESTOS TYPE/S IDENTIFIED BS/9/5 45 Workshop, external roof Cement CHRYSOTILE CROCIDOLITE BS/9/6 46 Workshop 9, void between workshop 9 & w/c block, pipe insulation Thermal insulation AMOSITE CHRYSOTILE BS/9/7 47 Workshop 9, external roof, cement also to external canopy Cement CHRYSOTILE CROCIDOLITE BS/9/8 48 Workshop 8, external roof, cement sheets Cement CHRYSOTILE CROCIDOLITE BS/9/9 49 Workshop 8, entrance lobby, floor Tile N.A.D.I.S BS/9/ 5 Workshop 8, main area, sink pad Bitumen CHRYSOTILE BS/9/ 5 Workshop 5, external vertical cladding Cement CHRYSOTILE CROCIDOLITE BS/9/ 5 Workshop 5, external roof sheet Cement CHRYSOTILE CROCIDOLITE BS/9/3 53 Workshop 5, workshop, high level pipe Thermal insulation N.A.D.I.S insulation BS/9/4 54 Workshop 3, external rood sheet Cement CHRYSOTILE CROCIDOLITE BS/9/5 55 Workshop 3, gable end, vertical cladding Cement CHRYSOTILE CROCIDOLITE BS/9/6 56 Workshop, workshop, sink pad Bitumen N.A.D.I.S BS/9/7 57 Workshop, gable end, external vertical cladding Cement CHRYSOTILE CROCIDOLITE BS/9/8 58 Workshop, external roof sheet Cement CHRYSOTILE CROCIDOLITE BS/9/9 59 Workshop 4, gable end & side wall, vertical cladding Cement CHRYSOTILE CROCIDOLITE BS/9/3 6 Workshop 4, external roof sheets Cement CHRYSOTILE CROCIDOLITE BS/9/3 6 Workshop 4, first floor cabin, external Artex N.A.D.I.S wall BS/9/3 6 Yellow building, main area, sink pad Bitumen N.A.D.I.S BS/9/33 63 Yellow building, external walls Artex N.A.D.I.S BS/9/34 64 Yellow building, ground floor, main area, beneath laminate flooring BS/9/35 65 George Lucas, second floor, stairwell, stair nosings (from second - ground floor) BS/9/36 66 George Lucas, second floor, tea point, riser panel, boarding BS/9/37 67 George Lucas, second floor, tea point, sink pad Vinyl Stair nosing Boarding Bitumen N.A.D.I.S N.A.D.I.S N.A.D.I.S N.A.D.I.S AA/LD/9- Directors: P J Abrey. T.M. Abrey, D Abrey, L Abrey Issue date:.. Reg Office: Unit 6, Blenheim Court, Hurricane Way, Wickford Business Park, SS 8YT. Company Reg No: 5689 Page of 4

18 Airtech Analysis Ltd Asbestos Consultancy, Analysis, Monitoring Environmental Surveying, R.I.C.E Member Unit 6, Blenheim Court, Hurricane Way, 68 Wickford Business Park, Wickford, Essex, SS 8YT Tel: (4hrs) Facsimile: E mail: enquiries@airtechanalysisltd.com LABORATORY SAMPLE NO CLIENT SAMPLE NO SAMPLE LOCATION MATERIAL DESCRIPTION ASBESTOS TYPE/S IDENTIFIED BS/9/38 68 George Lucas, first floor, staircase Stair nosing N.A.D.I.S BS/9/39 69 Workshop, main workshop roof, Sprayed insulation N.A.D.I.S sprayed insulation BS/9/4 7 Workshop, main workshop roof sheet Cement CHRYSOTILE CROCIDOLITE BS/9/4 7 Workshop, gable end & sides, vertical cladding Cement CHRYSOTILE CROCIDOLITE BS/9/4 7 Ancillary block north, ground floor, room Putty N.A.D.I.S 9, glazing putty BS/9/43 73 Ancillary block north, central staircase, Debris CROCIDOLITE ground floor riser, debris BS/9/44 74 Ancillary block north, ground floor, Debris CROCIDOLITE corridor, riser outside room BS/9/45 75 Ancillary block north, ground floor, Debris CROCIDOLITE corridor, riser outside room 3, debris BS/9/46 76 Ancillary block north, ground floor, Debris CROCIDOLITE corridor, riser outside room 4, debris BS/9/47 77 Ancillary block north, ground floor, Debris CROCIDOLITE corridor, riser outside room 6, debris BS/9/48 78 Ancillary block, south staircase, riser Debris CROCIDOLITE BS/9/49 79 Ancillary block north, first floor corridor, Cable insulation CHRYSOTILE ceiling void BS/9/5 8 Ancillary block north, first floor riser Debris N.A.D.I.S between w/c BS/9/5 8 Ancillary block north, first floor riser, between w/c s Cement AMOSITE CHRYSOTILE BS/9/5 8 Ancillary block, second floor, 9B Insulating board AMOSITE Louvers, ceiling BS/9/53 83 Ancillary block, plant room south, Boarding N.A.D.I.S second floor, door lining, boarding BS/9/54 84 Ancillary block, plant room north, duct Textile CHRYSOTILE gasket BS/9/55 85 Ancillary block, plant room north, corridor, cement pipe Cement AMOSITE CHRYSOTILE BS/9/56 86 Ancillary block, plant room north, Insulating board CHRYSOTILE corridor, opposite electrics, ceiling board BS/9/57 87 Ancillary block, plant room north, stage Insulating board AMOSITE 7, plenum & louvers, ceilings, unsealed BS/9/58 88 Ancillary block north, ground floor riser, next to w/c s Debris CHRYSOTILE CROCIDOLITE BS/9/59 89 Ancillary block north, stairwell, above Insulating board AMOSITE entrance door, boarding BS/9/6 9 Stage 7, gantry staircase on steel Debris CROCIDOLITE column, debris BS/9/6 9 Stage 7, fire exit lobby, floor Black tile CHRYSOTILE AA/LD/9- Directors: P J Abrey. T.M. Abrey, D Abrey, L Abrey Issue date:.. Reg Office: Unit 6, Blenheim Court, Hurricane Way, Wickford Business Park, SS 8YT. Company Reg No: 5689 Page 3 of 4

19 Airtech Analysis Ltd Asbestos Consultancy, Analysis, Monitoring Environmental Surveying, R.I.C.E Member Unit 6, Blenheim Court, Hurricane Way, 68 Wickford Business Park, Wickford, Essex, SS 8YT Tel: (4hrs) Facsimile: E mail: enquiries@airtechanalysisltd.com LABORATORY SAMPLE NO CLIENT SAMPLE NO SAMPLE LOCATION MATERIAL DESCRIPTION ASBESTOS TYPE/S IDENTIFIED BS/9/6 9 Stage 8, storeroom, office, floor Black tile CHRYSOTILE BS/9/63 93 Stage 8, gantry staircase on steel beam, debris BS/9/64 94 John Maxwell, stage 5, high level fascia panels, boarding BS/9/65 95 John Maxwell, stage 5, steel beams, sprayed insulation BS/9/66 96 John Maxwell, stage 5, external canopy, boarding BS/9/67 97 Underground, car park, store room doors Key: N.A.D.I.S = No asbestos detected in sample Debris Boarding Sprayed insulation Boarding Dura steel N.A.D.I.S N.A.D.I.S N.A.D.I.S N.A.D.I.S CHRYSOTILE CROCIDOLITE AMOSITE Samples analysed by: D. O Flaherty Signature Certificate issued by: Position: G. Freeman Consultancy Manager Signature AA/LD/9- Directors: P J Abrey. T.M. Abrey, D Abrey, L Abrey Issue date:.. Reg Office: Unit 6, Blenheim Court, Hurricane Way, Wickford Business Park, SS 8YT. Company Reg No: 5689 Page 4 of 4

20 Elstree Film Studios, Shenley Rd, Borehamwood, WD6 GJ M H Goldsmith & Sons Ltd Survey No /934 Survey Date / - //5 SURVEY INSPECTION DATA (Appendix B) 4

21 Elstree Film Studios Ltd, Borehamwood, WD6 GJ John Maxwell Windows Sample Ref,: Second floor Room of Sample Room 8 Beneath windows HIGH ACCESS lm (each) Date //5 CEMENT PRODUCT GOOD CONDITION SEALED BS/44985/ CHRYSOTILE Total : Material Assessment 4 MINOR DISTURBANCE DAILY 3 Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment LOW PRIORITY (<) Asbestos cement 'etonite' window sills (In all rooms from -4) Document & Manage MONTHS

22 Elstree Film Studios Ltd, Borehamwood, WD6 GJ John Maxwell Acoustic sink pads Sample Ref,: Second floor Room of Sample Tea Room Beneath sink unit LOW ACCESS >m Date //5 RESINS GOOD CONDITION SEALED BS/44985/ CHRYSOTILE Total : Material Assessment 4 MINOR DISTURBANCE DAILY 3 Liklehood of Disturbance INTERNAL SMALL ROOM Human Exposure Potential LOW Total : Priority Assessment LOW PRIORITY (<) Asbestos bitumen acoustic pads beneath sink unit Document & Manage MONTHS

23 Elstree Film Studios Ltd, Borehamwood, WD6 GJ John Maxwell Sample Ref,: 3 Second floor Room of Sample Tea room tile HIGH ACCESS m Date //5 RESINS FAIR CONDITION SEALED BS/44985/3 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS beige floor tile and bitumen

24 Elstree Film Studios Ltd, Borehamwood, WD6 GJ John Maxwell Wall board Sample Ref,: 4 Second floor Room of Sample Plant room Next to access ladder LOW ACCESS 4m Date //5 INSULATION BOARD FAIR CONDITION SEALED BS/44985/4 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS high level insulation board to wall

25 Elstree Film Studios Ltd, Borehamwood, WD6 GJ John Maxwell Sample Ref,: 5 Second floor Room of Sample Plant room above lift shaft MEDIUM ACCESS 3m Date //5 INSULATION BOARD POOR CONDITION SEALED BS/44985/5 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS insulation board forming boxing to floor

26 Elstree Film Studios Ltd, Borehamwood, WD6 GJ John Maxwell Ceiling Sample Ref,: 6 Second floor Room of Sample Plant room Around beams to ceiling MEDIUM ACCESS 6LM Date //5 THERMAL INSULATION GOOD CONDITION SEALED BS/44985/6 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS sprayed insulation around steel beams (also vertical)

27 Elstree Film Studios Ltd, Borehamwood, WD6 GJ John Maxwell Ceiling Sample Ref,: 7 Second floor Room of Sample Tank room Around beams HIGH ACCESS LM Date //5 THERMAL INSULATION GOOD CONDITION SEALED BS/44985/7 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS sprayed insulation around beams above switch room

28 Elstree Film Studios Ltd, Borehamwood, WD6 GJ John Maxwell Sample Ref,: 8 Second floor Room of Sample Switch room tile HIGH ACCESS m Date //5 RESINS FAIR CONDITION SEALED BS/44985/8 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS beige floor tile and bitumen

29 Elstree Film Studios Ltd, Borehamwood, WD6 GJ John Maxwell Ceiling Sample Ref,: 9 Second floor Room of Sample Corridor Ceiling void LOW ACCESS m Date //5 INSULATION BOARD GOOD CONDITION SEALED BS/44985/9 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS insulation board within ceiling void

30 Elstree Film Studios Ltd, Borehamwood, WD6 GJ John Maxwell Windows Sample Ref,: First floor Room of Sample Room 8 Beneath windows HIGH ACCESS lm (each) Date //5 CEMENT PRODUCT GOOD CONDITION SEALED BS/44985/ CHRYSOTILE Total : Material Assessment 4 MINOR DISTURBANCE DAILY 3 Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment LOW PRIORITY (<) Asbestos cement 'etonite' window sills (In all rooms from -9) Document & Manage MONTHS

31 Elstree Film Studios Ltd, Borehamwood, WD6 GJ John Maxwell Acoustic sink pads Sample Ref,: First floor Room of Sample Tea room Beneath sink unit LOW ACCESS <m Date //5 RESINS GOOD CONDITION SEALED BS/44985/ N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS bitumen acoustic pads beneath sink unit

32 Elstree Film Studios Ltd, Borehamwood, WD6 GJ John Maxwell Sample Ref,: First floor Room of Sample Tea room tile HIGH ACCESS m Date //5 RESINS GOOD CONDITION SEALED BS/44985/ N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS beige floor tile and bitumen

33 Elstree Film Studios Ltd, Borehamwood, WD6 GJ John Maxwell Wall Sample Ref,: 3 First floor Room of Sample Plant room Internal fascia MEDIUM ACCESS m Date //5 INSULATION BOARD GOOD CONDITION SEALED BS/44985/3 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS Mezzanine, internal fasica insulation board panel strip

34 Elstree Film Studios Ltd, Borehamwood, WD6 GJ John Maxwell Sample Ref,: 4 First floor Room of Sample Second sense corridor Above window LOW ACCESS m Date //5 INSULATION BOARD GOOD CONDITION SEALED BS/44985/4 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS insulation board above all windows

35 Elstree Film Studios Ltd, Borehamwood, WD6 GJ John Maxwell Ceiling Sample Ref,: 5 Ground floor Room of Sample Work shop B Around beams LOW ACCESS 4LM Date //5 THERMAL INSULATION FAIR CONDITION SEALED BS/44985/5 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS sprayed insulation around beams

36 Elstree Film Studios Ltd, Borehamwood, WD6 GJ John Maxwell Ceiling Sample Ref,: 6 Ground floor Room of Sample Stage 6, Store Around beam LOW ACCESS 3LM Date //5 THERMAL INSULATION FAIR CONDITION SEALED BS/44985/6 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS sprayed insulation around beam

37 Elstree Film Studios Ltd, Borehamwood, WD6 GJ John Maxwell Ceiling Sample Ref,: 7 Ground floor Room of Sample Workshop E Around beam LOW ACCESS 7LM Date //5 THERMAL INSULATION FAIR CONDITION SEALED BS/44985/7 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS sprayed insulation around beams

38 Elstree Film Studios Ltd, Borehamwood, WD6 GJ White House Window Sample Ref,: 8 Ground floor Room of Sample White House Glazing putty HIGH ACCESS LM Date 3//5 MASTICS GOOD CONDITION SEALED BS/44985/8 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS glazing putty

39 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Power House Sample Ref,: 9 Ground floor Room of Sample Substation void LOW ACCESS <m Date 3//5 DEBRIS POOR CONDITION UNSEALED BS/44985/9 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS debris within floor void

40 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Power House Sample Ref,: Ground floor Room of Sample Transformer room void LOW ACCESS m Date 3//5 DEBRIS POOR CONDITION UNSEALED BS/44985/ N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS debris within floor void

41 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Andrew Mitchell Ceiling Sample Ref,: First floor Room of Sample Stairwell Ceiling tile LOW ACCESS 5m Date 3//5 INSULATION BOARD GOOD CONDITION SEALED BS/44985/ N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS insulation board ceiling tiles

42 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Andrew Mitchell Wall panels Sample Ref,: First floor Room of Sample Corridor Either side of doors HIGH ACCESS m Date 3//5 INSULATION BOARD GOOD CONDITION SEALED BS/44985/ CHRYSOTILE / AMOSITE Total : Material Assessment 5 MINOR DISTURBANCE DAILY 3 Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment LOW PRIORITY (<) Asbestos insulation board infill panels either side of door Document and manage MONTHS

43 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Andrew Mitchell Bulkhead Sample Ref,: 3 First floor Room of Sample Corridor Above room 6 LOW ACCESS 3m Date 3//5 INSULATION BOARD GOOD CONDITION SEALED BS/44985/3 CHRYSOTILE / AMOSITE Total : Material Assessment 6 MINOR DISTURBANCE DAILY 3 Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment 4 MEDIUM PRIORITY ( - 7) Asbestos insulation board bulkhead above Room 6 Document and Manage MONTHS

44 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Andrew Mitchell Bulkhead Sample Ref,: 4 First floor Room of Sample Corridor 4 Above cupboards LOW ACCESS m Date 3//5 INSULATION BOARD GOOD CONDITION SEALED BS/44985/4 CHRYSOTILE / AMOSITE Total : Material Assessment 6 MINOR DISTURBANCE DAILY 3 Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment 4 MEDIUM PRIORITY ( - 7) Asbestos insulation boards, bulkhead above cupboards Document and Manage MONTHS

45 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Andrew Mitchell Ceiling Sample Ref,: 5 First floor Room of Sample Staircase Ceiling tiles LOW ACCESS 4m Date 3//5 INSULATION BOARD GOOD CONDITION SEALED BS/44985/5 CHRYSOTILE / AMOSITE Total : Material Assessment 6 LOW DISTURBANCE WEEKLY Liklehood of Disturbance INTERNAL SMALL ROOM Human Exposure Potential LOW Total : Priority Assessment 4 MEDIUM PRIORITY ( - 7) Asbestos insulation board ceiling tiles in staircase to plant room Document and Manage MONTHS

46 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Andrew Mitchell Distribution Board Sample Ref,: 6 Second floor Room of Sample Duct vent Fuse carrier LOW ACCESS LM Date 3//5 TEXTILES FAIR CONDITION UNSEALED BS/44985/6 CHRYSOTILE Total : Material Assessment 7 LOW DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL SMALL ROOM Human Exposure Potential LOW Total : Priority Assessment 4 MEDIUM PRIORITY ( - 7) Asbestos disused distributor board fuse carrier rope. Encapsulate, Document and Manage MONTHS

47 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Power House Sample Ref,: 7 Second floor Room of Sample Duct vent Beneath air duct MEDIUM ACCESS m Date 3//5 DEBRIS POOR CONDITION 3 3 UNSEALED 3 BS/44985/7 CHRYSOTILE Total : Material Assessment HIGH DISTURBANCE 3 INFREQUENT Liklehood of Disturbance INTERNAL SMALL ROOM Human Exposure Potential MEDIUM Total : Priority Assessment 7 7 HIGH PRIORITY (>7) Asbestos debris to floor beneath air duct Remove ASAP

48 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Andrew Mitchell Wall conduit Sample Ref,: 8 Second floor Room of Sample Boiler room Fuse carrier MEDIUM ACCESS Small Date 3//5 TEXTILES FAIR CONDITION UNSEALED BS/44985/8 CHRYSOTILE Total : Material Assessment 7 MEDIUM DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL SMALL ROOM Human Exposure Potential MEDIUM Total : Priority Assessment 5 MEDIUM PRIORITY ( - 7) Asbestos carrier rope to discarded fuse Remove if redundant. MONTHS

49 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Andrew Mitchell Ceiling Sample Ref,: 9 Second floor Room of Sample Landing Ceiling board LOW ACCESS m Date 3//5 INSULATION BOARD GOOD CONDITION SEALED BS/44985/9 CHRYSOTILE / AMOSITE Total : Material Assessment 6 MINOR DISTURBANCE DAILY 3 Liklehood of Disturbance INTERNAL SMALL ROOM Human Exposure Potential LOW Total : Priority Assessment 4 MEDIUM PRIORITY ( - 7) Asbestos insulation board forming ceiling Document and Manage MONTHS

50 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Andrew Mitchell Acoustic sink pads Sample Ref,: 3 Second floor Room of Sample Kitchen Beneath sink unit LOW ACCESS Small Date 3//5 RESINS GOOD CONDITION SEALED BS/44985/3 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS bitumen acoustic pads beneath sink unit

51 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Andrew Mitchell Stairs Sample Ref,: 3 Ground floor Room of Sample Staircase Stair nosing HIGH ACCESS LM Date 7//5 PLASTICS GOOD CONDITION SEALED BS/9/ N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS stair nosings to steps

52 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Enigma Wall Sample Ref,: 3 First floor Room of Sample Room 7a Wallboard LOW ACCESS 5m Date 7//5 INSULATION BOARD GOOD CONDITION SEALED BS/9/ N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS partition wall board

53 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Enigma Wall Sample Ref,: 33 First floor Room of Sample Corridor Outside room 5 MEDIUM ACCESS m Date 7//5 INSULATION BOARD GOOD CONDITION SEALED BS/9/3 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS wallboard, also runs into Room 6

54 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Enigma Doors Sample Ref,: 34 First floor Room of Sample Room 3b Loading bay doors HIGH ACCESS 4m Date 7//5 INSULATION BOARD GOOD CONDITION SEALED BS/9/4 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS lining to loading bay doors

55 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Enigma Wall Sample Ref,: 35 First floor Room of Sample Room 5 Around door LOW ACCESS m Date 7//5 INSULATION BOARD GOOD CONDITION SEALED BS/9/5 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS wallboard surrounding doorway

56 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Enigma Pipework Sample Ref,: 36 Unit 4 Room of Sample Unit 4 Wall LOW ACCESS <LM Date 7//5 PIPE INSULATION FAIR CONDITION UNSEALED 3 BS/9/6 CHRYSOTILE / AMOSITE Total : Material Assessment 9 LOW DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL SMALL ROOM Human Exposure Potential LOW Total : Priority Assessment 3 MEDIUM PRIORITY ( - 7) Asbestos insulation to high level pipe section Encapsulate, Document and Manage MONTHS

57 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Enigma Pipework Sample Ref,: 37 Media Powerhouse Room of Sample Outside lift Wall LOW ACCESS LM Date 7//5 THERMAL INSULATION GOOD CONDITION SEALED BS/9/7 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS insulation to high level pipes

58 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Enigma Wall Sample Ref,: 38 Ground floor Room of Sample Unit 7, Plant room Low level wall HIGH ACCESS m Date 7//5 DEBRIS POOR CONDITION 3 3 UNSEALED 3 BS/9/8 CHRYSOTILE / AMOSITE Total : Material Assessment HIGH DISTURBANCE 3 INFREQUENT Liklehood of Disturbance INTERNAL SMALL ROOM Human Exposure Potential HIGH 3 Total : Priority Assessment 7 8 HIGH PRIORITY (>7) Asbestos debris/residue to low level wall area Remove ASAP

59 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Enigma Fuse box Sample Ref,: 39 Ground floor Room of Sample Unit 7, Plant room Fuses MEDIUM ACCESS Small Date 7//5 TEXTILES FAIR CONDITION UNSEALED BS/9/9 CHRYSOTILE Total : Material Assessment 7 LOW DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL SMALL ROOM Human Exposure Potential LOW Total : Priority Assessment 3 MEDIUM PRIORITY ( - 7) Asbestos rope flash bands within (and on) fuse box Remove discarded fuse then Document and Manage remaining MONTHS

60 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Enigma Isolator Sample Ref,: 4 Ground floor Room of Sample Unit 7, Plant room Connectors LOW ACCESS Small Date 7//5 PAPER GOOD CONDITION SEALED BS/9/ N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS paper flash guards within isolator

61 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Enigma Wall Sample Ref,: 4 Ground floor Room of Sample Unit 7, Plant room Debris to wall MEDIUM ACCESS <m Date 7//5 DEBRIS POOR CONDITION 3 3 UNSEALED 3 BS/9/ CHRYSOTILE / AMOSITE Total : Material Assessment HIGH DISTURBANCE 3 INFREQUENT Liklehood of Disturbance INTERNAL SMALL ROOM Human Exposure Potential HIGH 3 Total : Priority Assessment 7 8 HIGH PRIORITY (>7) Asbestos debris/residue to wall behind pipes Remove ASAP

62 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Enigma Boarding Sample Ref,: 4 Ground floor Room of Sample Unit 5, Electric cupboard Walls/Ceiling MEDIUM ACCESS 3m Date 7//5 INSULATION BOARD POOR CONDITION 3 UNSEALED 3 BS/9/ CHRYSOTILE / AMOSITE Total : Material Assessment MEDIUM DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL SMALL ROOM Human Exposure Potential MEDIUM Total : Priority Assessment 6 6 MEDIUM PRIORITY ( - 7) Asbestos insulation board to walls and ceiling Remove damaged then Encapsulate, Document and Manage remaining MONTHS

63 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Enigma Acoustic sink pads Sample Ref,: 43 Ground floor Room of Sample Unit 5 Beneath sink unit LOW ACCESS Small Date 7//5 RESINS GOOD CONDITION SEALED BS/9/3 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS bitumen acoustic pads beneath sink unit

64 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop Roof Sample Ref,: 44 Roof Room of Sample Workshop External Roof LOW ACCESS m Date 8//5 CEMENT PRODUCT FAIR CONDITION UNSEALED BS/9/4 CHRYSOTILE Total : Material Assessment 6 MINOR DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment 8 3 LOW PRIORITY (<) Asbestos cement corrugated roof sheets Document and Manage (beyond non asbestos boards internally) MONTHS

65 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop Roof Sample Ref,: 45 Roof Room of Sample Workshop External Roof LOW ACCESS m Date 8//5 CEMENT PRODUCT FAIR CONDITION UNSEALED BS/9/5 CHRYSOTILE / CROCIDOLITE Total : Material Assessment 6 MINOR DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment 8 3 LOW PRIORITY (<) Asbestos cement corrugated roof sheets Document and Manage (beyond non asbestos boards internally) MONTHS

66 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop 9 Pipe Sample Ref,: 46 Ground floor Room of Sample Workshop 9 Void between Workshop 9 & WC LOW ACCESS >LM Date 8//5 THERMAL INSULATION FAIR CONDITION 3 SEALED BS/9/6 CHRYSOTILE / AMOSITE Total : Material Assessment 8 MINOR DISTURBANCE INFREQUENT Liklehood of Disturbance CONFINED SPACE 3 Human Exposure Potential LOW Total : Priority Assessment 4 MEDIUM PRIORITY ( - 7) Asbestos pipe insulation, at high level within void Document and Manage MONTHS

67 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop 9 Roof Sample Ref,: 47 Roof Room of Sample Workshop 9 External Roof LOW ACCESS 4m Date 8//5 CEMENT PRODUCT FAIR CONDITION UNSEALED BS/9/7 CHRYSOTILE / CROCIDOLITE Total : Material Assessment 6 MINOR DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment 8 3 LOW PRIORITY (<) Asbestos cement corrugated roof sheets (also to external canopy) Document and Manage MONTHS

68 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop 8 Roof Sample Ref,: 48 Roof Room of Sample Workshop 8 External Roof LOW ACCESS m Date 8//5 CEMENT PRODUCT FAIR CONDITION UNSEALED BS/9/8 CHRYSOTILE / CROCIDOLITE Total : Material Assessment 6 MINOR DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment 8 3 LOW PRIORITY (<) Asbestos cement corrugated roof sheets Document and Manage MONTHS

69 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop 8 Sample Ref,: 49 Ground floor Room of Sample Entrance Lobby tile HIGH ACCESS m Date 8//5 RESINS GOOD CONDITION SEALED BS/9/9 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS 'cream' floor tiles

70 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop 8 Acoustic sink pads Sample Ref,: 5 Ground floor Room of Sample Main area Beneath sink unit LOW ACCESS Small Date 8//5 RESINS GOOD CONDITION SEALED BS/9/5 CHRYSOTILE Total : Material Assessment 3 MINOR DISTURBANCE DAILY 3 Liklehood of Disturbance INTERNAL SMALL ROOM Human Exposure Potential LOW Total : Priority Assessment LOW PRIORITY (<) Asbestos bitumen acoustic pads beneath sink unit Document and Manage MONTHS

71 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop 5 Wall Sample Ref,: 5 Ground floor Room of Sample Workshop 5 Above wall sections LOW ACCESS 5m Date 8//5 CEMENT PRODUCT FAIR CONDITION UNSEALED BS/9/ CHRYSOTILE / CROCIDOLITE Total : Material Assessment 6 MINOR DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment 8 3 LOW PRIORITY (<) Asbestos cement forming high level corrugated vertical cladding Document and Manage MONTHS

72 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop 5 Roof Sample Ref,: 5 Roof Room of Sample Workshop 5 External Roof LOW ACCESS m Date 8//5 CEMENT PRODUCT FAIR CONDITION UNSEALED BS/9/ CHRYSOTILE / CROCIDOLITE Total : Material Assessment 6 MINOR DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment 8 3 LOW PRIORITY (<) Asbestos cement corrugated roof sheets Document and Manage MONTHS

73 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop 5 Pipework Sample Ref,: 53 Ground floor Room of Sample Workshop 5 High level pipes LOW ACCESS 3LM Date 8//5 THERMAL INSULATION FAIR CONDITION SEALED BS/9/3 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS insulation to high level pipes

74 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop 3 Roof Sample Ref,: 54 Roof Room of Sample Workshop 3 External Roof LOW ACCESS 3m Date 8//5 CEMENT PRODUCT FAIR CONDITION UNSEALED BS/9/4 CHRYSOTILE / CROCIDOLITE Total : Material Assessment 6 MINOR DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment 8 3 LOW PRIORITY (<) Asbestos cement corrugated roof sheets Document and Manage MONTHS

75 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop 3 Wall Sample Ref,: 55 Ground floor Room of Sample Workshop 3 Above wall sections LOW ACCESS 5m Date 8//5 CEMENT PRODUCT FAIR CONDITION UNSEALED BS/9/5 CHRYSOTILE / CROCIDOLITE Total : Material Assessment 6 MINOR DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment 8 3 LOW PRIORITY (<) Asbestos cement forming corrugated vertical cladding Document and Manage MONTHS

76 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop Acoustic sink pads Sample Ref,: 56 Ground floor Room of Sample Workshop Beneath sink unit LOW ACCESS Small Date 8//5 RESINS GOOD CONDITION SEALED BS/9/6 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS bitumen acoustic pads beneath sink unit

77 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop Wall Sample Ref,: 57 Ground floor Room of Sample Workshop Above wall section LOW ACCESS m Date 8//5 CEMENT PRODUCT FAIR CONDITION UNSEALED BS/9/7 CHRYSOTILE / CROCIDOLITE Total : Material Assessment 6 MINOR DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment 8 3 LOW PRIORITY (<) Asbestos cement forming corrugated vertical cladding Repair then Document and Manage MONTHS

78 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop Roof Sample Ref,: 58 Roof Room of Sample Workshop External Roof LOW ACCESS 3m Date 8//5 CEMENT PRODUCT FAIR CONDITION UNSEALED BS/9/8 CHRYSOTILE / CROCIDOLITE Total : Material Assessment 6 MINOR DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment 8 3 LOW PRIORITY (<) Asbestos cement corrugated roof sheets Document and Manage MONTHS

79 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop 4 Wall Sample Ref,: 59 Ground floor Room of Sample Workshop 4 Above wall sections MEDIUM ACCESS 3m Date 9//5 CEMENT PRODUCT FAIR CONDITION UNSEALED BS/9/9 CHRYSOTILE / CROCIDOLITE Total : Material Assessment 6 MINOR DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment 8 3 LOW PRIORITY (<) Asbestos cement forming corrugated vertical cladding Document and Manage MONTHS

80 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop 4 Roof Sample Ref,: 6 Roof Room of Sample Workshop 4 External Roof LOW ACCESS m Date 9//5 CEMENT PRODUCT FAIR CONDITION UNSEALED BS/9/3 CHRYSOTILE / CROCIDOLITE Total : Material Assessment 6 MINOR DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment 8 3 LOW PRIORITY (<) Asbestos corrugated cement roof sheets Document and Manage MONTHS

81 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop 4 Sample Ref,: 6 First floor Room of Sample Cabin room External wall of cabin HIGH ACCESS 8m Date 9//5 TEXTURED COATING GOOD CONDITION SEALED BS/9/3 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS artex to cabin external wall

82 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Yellow building Acoustic sink pads Sample Ref,: 6 Ground floor Room of Sample Main area Beneath sink unit LOW ACCESS Small Date 9//5 RESINS GOOD CONDITION SEALED BS/9/3 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS bitumen acoustic pads beneath sink unit (identical sink unit on st floor)

83 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Yellow building Wall Sample Ref,: 63 Ground floor Room of Sample Yellow building External wall MEDIUM ACCESS 8m Date 9//5 TEXTURED COATING GOOD CONDITION SEALED BS/9/33 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS textured coating to external wall

84 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Yellow building Sample Ref,: 64 Ground floor Room of Sample Main area Beneath laminate flooring LOW ACCESS 8m Date 9//5 PLASTICS GOOD CONDITION SEALED BS/9/34 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS vinyl beneath laminate flooring

85 Elstree Film Studios Ltd, Borehamwood, WD6 GJ George Lucas Stair Sample Ref,: 65 Ground floor Room of Sample Stairwell Stair nosings HIGH ACCESS 4LM Date 9//5 PLASTICS GOOD CONDITION SEALED BS/9/35 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS stair nosings to steps (ground floor to second floor)

86 Elstree Film Studios Ltd, Borehamwood, WD6 GJ George Lucas Wall Sample Ref,: 66 Second floor Room of Sample Tea point Riser panels LOW ACCESS 3m Date 9//5 INSULATION BOARD GOOD CONDITION SEALED BS/9/36 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS insulation board forming riser panels

87 Elstree Film Studios Ltd, Borehamwood, WD6 GJ George Lucas Acoustic sink pads Sample Ref,: 67 First floor Room of Sample Tea room Beneath sink unit LOW ACCESS Small Date 9//5 RESINS GOOD CONDITION SEALED BS/9/37 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS bitumen acoustic pads beneath sink unit

88 Elstree Film Studios Ltd, Borehamwood, WD6 GJ George Lucas Stair Sample Ref,: 68 First floor Room of Sample Staircase Stair nosings HIGH ACCESS 4LM Date 9//5 PLASTICS GOOD CONDITION SEALED BS/9/38 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS stair nosings to steps (to all three floors)

89 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop Insulation Sample Ref,: 69 Ground floor Room of Sample Main workshop Roof LOW ACCESS 4m Date 9//5 THERMAL INSULATION GOOD CONDITION SEALED BS/9/39 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS sprayed insulation to underside of roof

90 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop Roof Sample Ref,: 7 Roof Room of Sample External External Roof LOW ACCESS 4m Date 8//5 CEMENT PRODUCT FAIR CONDITION UNSEALED BS/9/4 CHRYSOTILE / CROCIDOLITE Total : Material Assessment 6 MINOR DISTURBANCE INFREQUENT Liklehood of Disturbance EXTERNAL Human Exposure Potential LOW Total : Priority Assessment 7 3 LOW PRIORITY (<) Asbestos cement corrugated roof sheets Document and Manage (beyond insulation internally) MONTHS

91 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Workshop Wall Sample Ref,: 7 Ground floor Room of Sample External Above wall sections LOW ACCESS 5m Date 9//5 CEMENT PRODUCT FAIR CONDITION SEALED BS/9/4 CHRYSOTILE / CROCIDOLITE Total : Material Assessment 6 MINOR DISTURBANCE INFREQUENT Liklehood of Disturbance EXTERNAL Human Exposure Potential LOW Total : Priority Assessment 7 3 LOW PRIORITY (<) Asbestos cement forming corrugated vertical cladding Document and Manage MONTHS

92 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Ancilliary block north Window Sample Ref,: 7 Ground floor Room of Sample Room 9 Glazing putty MEDIUM ACCESS 5LM Date 3//5 MASTICS GOOD CONDITION SEALED BS/9/4 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS glazing putty to window frame

93 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Ancilliary block north Service riser Sample Ref,: 73 Ground floor Room of Sample Central staircase LOW ACCESS <m Date 3//5 DEBRIS POOR CONDITION 3 3 UNSEALED 3 BS/9/43 CROCIDOLITE 3 Total : Material Assessment HIGH DISTURBANCE 3 INFREQUENT Liklehood of Disturbance CONFINED SPACE 3 Human Exposure Potential HIGH 3 Total : Priority Assessment 9 HIGH PRIORITY (>7) Asbestos debris to floor within central staircase service riser Environmental clean of immediate area ASAP

94 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Ancilliary block north Service riser Sample Ref,: 74 Ground floor Room of Sample Corridor (adjacent to room ) LOW ACCESS <m Date 3//5 DEBRIS POOR CONDITION 3 3 UNSEALED 3 BS/9/44 CROCIDOLITE 3 Total : Material Assessment HIGH DISTURBANCE 3 INFREQUENT Liklehood of Disturbance CONFINED SPACE 3 Human Exposure Potential HIGH 3 Total : Priority Assessment 9 HIGH PRIORITY (>7) Asbestos debris to floor within corridor (room ) service riser Environmental clean of immediate area ASAP

95 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Ancilliary block north Service Riser Sample Ref,: 75 Ground floor Room of Sample Corridor (adjacent to room 3) LOW ACCESS <m Date 3//5 DEBRIS POOR CONDITION 3 3 UNSEALED 3 BS/9/46 CROCIDOLITE 3 Total : Material Assessment HIGH DISTURBANCE 3 INFREQUENT Liklehood of Disturbance CONFINED SPACE 3 Human Exposure Potential HIGH 3 Total : Priority Assessment 9 HIGH PRIORITY (>7) Asbestos debris to floor within corridor (room 3) service riser Environmental clean of immediate area ASAP

96 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Ancilliary block north Service riser Sample Ref,: 76 Ground floor Room of Sample Corridor (adjacent to room 4) LOW ACCESS <m Date 3//5 DEBRIS POOR CONDITION 3 3 UNSEALED 3 BS/9/46 CROCIDOLITE 3 Total : Material Assessment HIGH DISTURBANCE 3 INFREQUENT Liklehood of Disturbance CONFINED SPACE 3 Human Exposure Potential HIGH 3 Total : Priority Assessment 9 HIGH PRIORITY (>7) Asbestos debris to floor within corridor (room 4) service riser Environmental clean of immediate area ASAP

97 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Ancilliary block north Service riser Sample Ref,: 77 Ground floor Room of Sample Corridor (adjacent to room 6) LOW ACCESS <m Date 3//5 DEBRIS POOR CONDITION 3 3 UNSEALED 3 BS/9/47 CROCIDOLITE 3 Total : Material Assessment HIGH DISTURBANCE 3 INFREQUENT Liklehood of Disturbance CONFINED SPACE 3 Human Exposure Potential HIGH 3 Total : Priority Assessment 9 HIGH PRIORITY (>7) Asbestos debris to floor within corridor (room 6) service riser Environmental clean of immediate area ASAP

98 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Ancilliary block Service Riser Sample Ref,: 78 Ground floor Room of Sample South staircase LOW ACCESS <m Date 3//5 DEBRIS POOR CONDITION 3 3 UNSEALED 3 BS/9/48 CROCIDOLITE 3 Total : Material Assessment HIGH DISTURBANCE 3 INFREQUENT Liklehood of Disturbance CONFINED SPACE 3 Human Exposure Potential HIGH 3 Total : Priority Assessment 9 HIGH PRIORITY (>7) Asbestos debris to floor within south staircase service riser Environmental clean of immediate area ASAP

99 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Ancilliary block north Electrical cable Sample Ref,: 79 First floor Room of Sample Corridor Corridor ceiling void LOW ACCESS LM Date 3//5 RESINS GOOD CONDITION SEALED BS/9/49 CHRYSOTILE Total : Material Assessment MINOR DISTURBANCE INFREQUENT Liklehood of Disturbance CONFINED SPACE 3 Human Exposure Potential LOW Total : Priority Assessment LOW PRIORITY (<) Asbestos bitumen coating to mains intake cable Document and Manage MONTHS

100 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Ancilliar block north W/C Service void Sample Ref,: 8 First floor Room of Sample W/C Riser/Void LOW ACCESS m Date //5 DEBRIS POOR CONDITION UNSEALED BS/9/5 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS debris to floor of W/C service void

101 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Ancilliary block W/C Service void (pipes) Sample Ref,: 8 First floor Room of Sample W/C Riser/Void Flue pipe LOW ACCESS LM Date 3//5 CEMENT PRODUCT GOOD CONDITION UNSEALED BS/9/8 CHRYSOTILE / AMOSITE Total : Material Assessment 5 LOW DISTURBANCE INFREQUENT Liklehood of Disturbance CONFINED SPACE 3 Human Exposure Potential LOW Total : Priority Assessment 5 MEDIUM PRIORITY ( - 7) Asbestos cement vertical flue pipe within W/C service void Encapsulate, Document and Manage MONTHS

102 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Ancilliary block Boarding Sample Ref,: 8 Third floor Room of Sample 9b Louvers Ceiling LOW ACCESS 4m Date 3//5 INSULATION BOARD FAIR CONDITION UNSEALED 3 BS/9/5 AMOSITE Total : Material Assessment 9 MINOR DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL SMALL ROOM Human Exposure Potential LOW Total : Priority Assessment 3 MEDIUM PRIORITY ( - 7) Asbestos insulation board to ceiling Encapsulate, Document and manage MONTHS

103 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Ancilliary block Door Sample Ref,: 83 Third floor Room of Sample Plant room Door lining HIGH ACCESS m Date //5 INSULATION BOARD GOOD CONDITION SEALED BS/9/53 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS insulation board lining to door

104 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Ancilliary block Air ducts Sample Ref,: 84 Third floor Room of Sample Plant room north (studio 8 Plenhum) Duct gaiter (gasket) MEDIUM ACCESS m Date 3//5 TEXTILES FAIR CONDITION SEALED BS/9/54 CHRYSOTILE Total : Material Assessment 6 LOW DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment LOW PRIORITY (<) Asbestos textile gaiter connecting air ducts Document and Manage MONTHS

105 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Ancilliary block Cement pipe Sample Ref,: 85 Third floor Room of Sample Plant room north, corridor Wall MEDIUM ACCESS 4LM Date 3//5 CEMENT PRODUCT FAIR CONDITION SEALED BS/9/55 CHRYSOTILE / AMOSITE Total : Material Assessment 6 MINOR DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment 8 3 LOW PRIORITY (<) Asbestos cement vertical flue pipe Encapsulate, Document and Manage MONTHS

106 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Ancilliary block Ceiling section Sample Ref,: 86 Third floor Room of Sample Plant room north, corridor Opposite electrics LOW ACCESS m Date 3//5 INSULATION BOARD GOOD CONDITION SEALED BS/9/56 CHRYSOTILE Total : Material Assessment 5 MINOR DISTURBANCE WEEKLY Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment LOW PRIORITY (<) Asbestos insulation board to ceiling section opposite electrics Document and Manage MONTHS

107 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Ancilliary block Ceiling board Sample Ref,: 87 Third floor Room of Sample Plant room north (studio 7 Plenhum) Plenum and louvers LOW ACCESS 4m Date 3//5 INSULATION BOARD FAIR CONDITION UNSEALED 3 BS/9/57 AMOSITE Total : Material Assessment 9 MINOR DISTURBANCE WEEKLY Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment 4 3 MEDIUM PRIORITY ( - 7) Asbestos insulation board panels to ceiling (partially covered) Encapsulate, Document and Manage MONTHS

108 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Ancilliary block W/C service riser Sample Ref,: 88 Ground floor Room of Sample W/C riser LOW ACCESS <m Date 3//5 DEBRIS POOR CONDITION 3 3 UNSEALED 3 BS/9/58 CHRYSOTILE / CROCIDOLITE 3 Total : Material Assessment HIGH DISTURBANCE 3 INFREQUENT Liklehood of Disturbance CONFINED SPACE 3 Human Exposure Potential HIGH 3 Total : Priority Assessment 9 HIGH PRIORITY (>7) Asbestos debris to floor of W/C service riser Environmental clean of immediate area ASAP

109 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Ancillary block north Wall (bulkghead) Sample Ref,: 89 Ground floor Room of Sample Stairwell Above entrance door LOW ACCESS m Date 3//5 INSULATION BOARD GOOD CONDITION SEALED BS/9/59 AMOSITE Total : Material Assessment 6 MINOR DISTURBANCE DAILY 3 Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment 5 MEDIUM PRIORITY ( - 7) Asbestos insulation board forming high level bulkhead Document and Manage MONTHS

110 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Stage 7 Structural beams Sample Ref,: 9 Ground floor Room of Sample Gantry staircase Walls MEDIUM ACCESS m Date 3//5 DEBRIS POOR CONDITION 3 3 ENCAPSULATED BS/9/6 CROCIDOLITE 3 Total : Material Assessment LOW DISTURBANCE INFREQUENT Liklehood of Disturbance INTERNAL LARGE ROOM Human Exposure Potential LOW Total : Priority Assessment 3 3 MEDIUM PRIORITY ( - 7) Asbestos residue to steel columns beyond MMMF protection Encapsulate, Document and Manage (full extent unknown) MONTHS

111 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Stage 7 tile Sample Ref,: 9 Ground floor Room of Sample Fire exit lobby HIGH ACCESS m Date 3//5 RESINS GOOD CONDITION SEALED BS/9/6 CHRYSOTILE Total : Material Assessment 4 MINOR DISTURBANCE DAILY 3 Liklehood of Disturbance INTERNAL SMALL ROOM Human Exposure Potential LOW Total : Priority Assessment LOW PRIORITY (<) Asbestos black floor tiles throughout Document and Manage MONTHS

112 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Stage 8 tiles Sample Ref,: 9 Ground floor Room of Sample Store room office MEDIUM ACCESS m Date 3//5 RESINS FAIR CONDITION SEALED BS/9/6 CHRYSOTILE Total : Material Assessment 5 MINOR DISTURBANCE DAILY 3 Liklehood of Disturbance INTERNAL SMALL ROOM Human Exposure Potential LOW Total : Priority Assessment 5 3 LOW PRIORITY (<) Asbestos black floor tile Document and Mange MONTHS

113 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Stage 8 Structural beams Sample Ref,: 93 Room of Sample Gantry staircase Ceiling LOW ACCESS <m Date 3//5 DEBRIS POOR CONDITION SEALED BS/9/63 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS residue to high level structural beams

114 Elstree Film Studios Ltd, Borehamwood, WD6 GJ John Maxwell High level fascia panels Sample Ref,: 94 Ground floor Room of Sample Stage 5 Wall LOW ACCESS 3m Date //5 INSULATION BOARD GOOD CONDITION SEALED BS/9/64 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS insulation board forming high level fascia to wall

115 Elstree Film Studios Ltd, Borehamwood, WD6 GJ John Maxwell Structural beams Sample Ref,: 95 Ground floor Room of Sample Stage 5 Ceiling LOW ACCESS 6LM Date //5 THERMAL INSULATION GOOD CONDITION SEALED BS/9/65 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS sprayed insulation to high level structural beams

116 Elstree Film Studios Ltd, Borehamwood, WD6 GJ John Maxwell Canopy Sample Ref,: 96 External Room of Sample Stage 5 Ceiling LOW ACCESS 5m Date //5 INSULATION BOARD GOOD CONDITION SEALED BS/9/66 N.A.D.I.S. Total : Material Assessment Liklehood of Disturbance Human Exposure Potential Total : Priority Assessment NADIS insulation board forming high level canopy ceiling

117 Elstree Film Studios Ltd, Borehamwood, WD6 GJ Car park Doors Sample Ref,: 97 Basement Room of Sample External Storeroom entry doors MEDIUM ACCESS m Date //5 INSULATION BOARD GOOD CONDITION SEALED BS/9/67 CHRYSOTILE / CROCIDOLITE 3 Total : Material Assessment 7 LOW DISTURBANCE INFREQUENT Liklehood of Disturbance EXTERNAL Human Exposure Potential LOW Total : Priority Assessment 9 3 LOW PRIORITY (<) Asbestos insulation board 'durasteel' doors to storeroom Document and Manage MONTHS