1 Please consult the manufacturer s installation manual for all details and requirements before making a final design layout decision. 72" Direct Vent Gas Fireplace MODEL FRONT HEIGHT WIDTH FRONT BACK WIDTH BACK HEIGHT WIDTH DEPTH VIEWING GLASS SIZE AREA Actual Framing Actual Framing Actual Framing Actual Framing* 83-1/2 84-1/4 83-1/2 84-1/4 30-9/ / /4 17-3/16" [437] 83-1/2" [2121] Ø8" [203] CENTERED ON APPLIANCE Top 8-5/8" [219] 18-1/8" [460] 71-1/2 x 12-1/2 * Framing depth will change if installing PVLP-SLP with a minimum vent configuration. See next page for details. GAS ACCESS ELECTRICAL ACCESS 23-13/16" [605] 8-1/4" [210] 3-7/16" [87] 75-1/16" [1907] 84-15/16" [2157] Front 13-3/8" [340] 9-3/8" [238] 30-9/16" [776] 4" [102] 39-1/2" [1003] 37" [940] *44-3/4" [1137] 2-5/16" [59] 7-11/16" [195] 2-13/16" [71] 2-1/16" [52] *Minimum Vent Height (using SLP90) Left Right Additional information can be found online at

2 PVLP-SLP MINIMUM Minimum HORIZONTAL Horizontal Footprint FOOTPRINT This diagram shows the scenario if the 12-1/2 inch measurement was not accommodated for prior to installation. The PVLP-BEK may be installed in the 5 inch gap or a small bump out may be created on the exterior wall to accommodate for the additional space needed. H*=12-1/2 inches if using PVLP-SLP plus one SLP elbow. This is the minimum vent con guration and is composed of the factory-installed 6 inch DVP component, DVP-2SL converter, SLP90 elbow and PVLP-SLP termination cap. 5- EXTERIOR SHEATHING WALL TO CAP TRANSITION CAN BE COMPLETED WITH PVLP-BEK 5 IN. 12- (TO BACK OF APPLIANCE) 1 IN. MIN. CLEARANCE INTERIOR SHEATHING The dimensions above assume: 2 in. X 6 in. exterior wall studs 1/2 in. thick interior and exterior wall sheathing material SLP90 DVP-2SL SIDE VIEW FACTORY- INSTALLED DVP PIPE 12-

3 Finishing Dimensions FINISHED OPENING DIMENSIONS NOTE: Sheetrock (1/2") may be installed up to appliance opening. WALL (1/2" SHEETROCK) 22-3/4" [579] 13-3/8" [340] 9-3/8" [238] 75" [1905] = 1/2" SHEET ROCK = APPLIANCE OPENING Clean Face Finish (Black Glass Interior) NOTE: Sheetrock (1/2") may be installed up to appliance opening. 3-3/4" [82] WALL (1/2" SHEETROCK) 27-11/16" [703] 11-13/16" [300] 2-1/2" [64] 1-1/4" [32] 1/2" [13] 2-1/2" [64] 23-13/16" [605] 9-7/8" [251] 3-7/8" [98] 70-1/16" [1780] 82" [2083] = 1/2" SHEETROCK = APPLIANCE OPENING = GRANITE SURROUND (Installed on top of 1/2" sheetrock) Black Granite Surround Finish (Black Glass Interior)

4 APPLIANCE LOCATION 35-1/4" [895] 29-3/4" [756] FRAMING DIMENSION DVP Pipe: 10" [254] SLP Pipe: 9" [229] [2139] 88" [2235] [2139] 124-3/8" [3159] [2139] HEADER DEPTH** 48" [1219] 36" [914] MANTEL PROJECTIONS 1/2" SHEETROCK/ COMBUSTIBLE FACING MATERIAL All measurements in inches 4 [2139] * Note 12-1/2" if using PVLP-SLP plush one SLP elbow. This is the minimum vent configuration and is composed of the factory-installed 6" DVP component, DVP-2SLP converter, SLP90 elbow and PVLP-SLP termination cap. See inset to right TO CEILING MEASUREMENTS FROM TOP EDGE OF THE OPENING DVP-2SL Combustible or Non-Combustible SLP90 6" DVP CLEARANCES TO COMBUSTIBLES 0" [2140] * Adjust framing dimensions for interior sheathing (such as sheetrock) ** Header depth not to exceed 3-1/2" *** If appliance is installed off of floor, maintain required clearances to combustibles. Construct platform in accordance with local building codes. **** See location diagram at top of page for PVLP-SLP minimum horizontal footprint. Rough opening depth will change if installing PVLP-SLP with minimum vent configuration. 36" [914] 0" **** 18-1/4" [464] MEASURE FROM TOP OF FIREPLACE OPENING Appliance may be installed off the floor*** 3 [787] *MEASUREMENT FROM BOTTOM OF FIREPLACE TO CEILING *53-3/4" [1365] MANTEL LEG/WALL PROJECTIONS - EXTENDING PAST THE FACE OF THE FIREPLACE Note: Clearance from opening to perpendicular wall. WALL PENETRATION DO NOT PACK WITH INSULATION OR OTHER MATERIAL 13" 10" 44-1/4" [1124] * TOP VIEW FIREPLACE OPENING 1/2" Sheetrock/Combustible facing material 13" 10" 4-1/2" MAXIMUM 4-1/2" MINIMUM UNLIMITED MANTEL LEG OR PERPENDICULAR WALL Shows minimum vertical vented PVLP-SLP: Factory installed 6" DVP pipe, SLP90 and included DVP-2SL. Acceptable on both sides of opening Combustible or Non-combustible

5 HEAT-ZONE KIT INSTALLATION 2 IN. X 6 IN. WALL FINISHED SURFACE 2 IN. X 4 IN. WALL FAN HOUSING FINISHED SURFACE 1/4 IN. (6 MM) ADJUSTABLE MOUNTING BRACKETS FAN HOUSING FRONT OF FAN HOUSING 14 IN. 14 IN. (13 MM) 4-4- Wall Mounting (2 X 6) Wall Mounting (2 X 4) HEAT-ZONE FLEX PIPE INSTALLATION 6-3/4 in. HEAT OUT FRAMING 8-5/8 IN. MINIMUM SPACE REQUIRED FOR 90 DEGREE BEND 18 in. 12-5/8 IN. PRODUCT LISTING CODES US ANSI Z CAN CSA UL307B Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury. Additional information can be found online at Web: heatnglo.com Phone: (888) (952) infoheatnglo.com GS/HNG/_0617