1 THE PLANNING GUIDE FOR INSULATION SOLUTIONS FROM THE BASEMENT TO THE ROOF. HIGH-QUALITY INSULATION. SUSTAINABLE LIVING.

2 The effective insulating materials from HOMATHERM. Top quality insulation. Reducing energy costs. Is your planning focussed on top quality insulation? Then you cannot go wrong with HOMATHERM. The extensive product range includes flexible wood and cellulose insulating batts, compression resistant wood insulation boards and loose cellulose fill. The diverse properties such as format, or hydrophobic, render these modern insulating materials and their ingenious combinations ideal for the insulation of roofs, walls, facades, ceilings or floors. These properties render HOMATHERM insulating materials excellently suited for protection from noise, heat and moisture decisive criteria for modern and healthy building and for reliable planning. This planning guide offers a variety of ingenious insulating solutions to choose from, for any application. Contents 5-star quality insulation... from page 04 FLOOR Tip: Our recommendation, your decision. The advantage icons highlight the advantages of each product at a glance. 1 This insulation is/has: 2 and in this configuration is particularly effective in ensuring: PITCHED ROOF between rafters, on rafters and under rafters... from page 06 FLAT ROOF Roof insulation... from page 20 TOP-STOREY CEILING Suitable for walking on and not suitable for walking on, timber beam and concrete ceilings...from page 22 Floor slabs...from page 44 CEILING Timber beam ceilings... from page 46 INSIDE WALL Metal and wood stud walls... from page 48 flexible suitable for clamping pressureresistant highly pressureresistant extremly pressureresistant easy to process suitable for machine processing waterproofed throughout stepped profile tongueand-groove energysaving heat protection moistureproofing sound insulation fireproofing ecological compatibility EXTERNAL WALL Masonry, cross laminated timber and timber frame walls, interior insulation... from page 30 BASEMENET CEILING Concrete and timber beam ceilings... from page 40 OVERVIEW OF PRODUCTS AND TYPES OF USE overview...page 52 overview...page 54 Contact...page

3 5-star quality insulation Invite our star graded quality home comfort standard into your home with effective HOMATHERM insulating materials. The planning tables below show three different colours representing our star quality grades. This will assist you in incorporating the quality star grading in your planning: 3-star grade 4-star grade 5-star grade U value (in W/m 2 K) 0.20 to 0.18 > 0.18 to 0.14 > 0.14 to 0.09 Protection from heat 10 hours 12 hours 13 hours Energy saving Protection from moisture Acoustic insulation Ecology ENERGY SAVING Avoiding costs and also preserving the environment. HOMATHERM offers you: U value of your choice Low thermal conductivity from = W/(mK) Dimensionally stable insulation PROTECTION FROM MOISTURE Sustainable home-comfort climate for generations. HOMATHERM offers you: Vapour-permeable construction Absorbing and adsorptive properties Excellent buffering of moisture in the building element PROTECTION FROM HEAT Enjoy heat protection phase shifted by > 10 hours. HOMATHERM offers you: High specific heat capacity High raw density Low thermal conductivity ACOUSTIC INSULATION For all demands. For a new quality of life. HOMATHERM offers you: Absorbing fibre structure Low dynamic rigidity High flow resistance per meter ECOLOGY 100 % tested environmentally safe insulating materials made of wood & cellulose. HOMATHERM offers you: Constructions without chemical wood protection Virtually no VOC and formaldehyde emission CO2-neutral process heat recovery RESULT RESULT RESULT RESULT RESULT Healthy indoor climate Thickness 220 mm 240 mm 320 mm Economical and responsible building Long-term structural protection Just 160 mm HOMATHERM insulation material delivers a 10 hour phase shift Pleasantly quiet living s Healthy indoor climate, building for healthy living 4 5

4 PITCHED ROOF of existing roofs with air-tight interior facing 1 Roof covering 2 Support battens, counter battens 3 HOMATHERM UD protect 4 HOMATHERM holzflex between rafters 5 Support battens recommendations Pitched roof: of existing roofs with air-tight interior facing 3 Overlay board UD protect 4 Flexible insulation batt holzflex i Detail: roof ridge Foil-free roof renovation easier, safer, more economical. 6 Air-tight interior facing (e. g. wood fiber panels with rendering) ideal for roof renovations for inclines from 15 without bonding the tongue-andgroove joints additional insulation up to 120 mm 25 % weight reduction, resulting in improved thermal conductivity and easier handling permeable to vapours, can buffer moisture temporarily and release it in a controlled manner fixes securely between rafters, no convection currents in the structural element HOMATHERM UD protect HOMATHERM holzflex Structurally secure due to moisture storage properties of the wood-fibre insulation Simple, uncomplicated design Cost savings of up to 30 % Use cuts of HOMATHERM holzflex as filling wool for complicated cavities. holzflex between rafters /en/planning Detailed information for roof renovation: /en/roof-renovation /product-information UD protect λ = W/mK = W/mK on rafters PITCHED ROOF 6 7

5 PITCHED ROOF 1 Roof covering 2 Support battens, counter battens recommendations Pitched roof: Roof renovation from outside Roof renovation from outside 3 HOMATHERM UD protect 3 Overlay board UD protect 4 Flexible insulation batt flexcl 4 Flexible insulation batt holzflex 4 HOMATHERM flexcl between rafters alternative: HOMATHERM holzflex, wind seal and overlay in one work step. HOMATHERM UD protect 5 Airtight membrane/vapour barrier (existing buildings) 6 Battens 7 Interior facing ideal for roof renovations for inclines from 15 without bonding the tongue-andgroove joints additional insulation up to 120 mm 25 % weight reduction, resulting in improved thermal conductivity and easier handling high-performance ideal for high sound insulation requirements keeps its shape between rafters and battens permeable to vapours, can buffer moisture temporarily and release it in a controlled manner fixes securely between rafters, no convection currents in the structural element HOMATHERM flexcl or HOMATHERM holzflex Additional insulation for renovations up to 120 mm Optimal heat protection due to excellent heat retention properties Weather protection up to 10 weeks prior to roof covering Secure the UD-Q11 protect underlay, up to 120 mm thick, with nails Konterlatte 40/ Sparren 60/ Drawing: ITW-Befestigungssysteme GmbH, holzflex UD protect λ = W/mK = W/mK between rafters on rafters /en/planning Detailed information for roof renovation: /en/roof-renovation /product-information flexcl = W/mK λ = 0.042W/mK UD protect λ = W/mK = W/mK between rafters on rafters ,248 4,05 9, ,249 4,00 9, ,226 4,55 10, ,227 4,50 10, ,207 5,00 11, ,208 4,95 11, ,191 5,50 12, ,192 5,45 12, ,173 6,05 14, ,174 6,00 14, ,160 6,45 15, ,161 6,45 15, ,150 6,90 17, ,151 6,85 17, ,140 7,35 18, ,141 7,30 18,3 PITCHED ROOF 8 9

6 PITCHED ROOF 1 Roof covering 2 Support battens, counter battens recommendations Pitched roof: from inside from inside 3 Existing permeable sarking membrane 4 Flexible insulation batt holzflex 5 4 Flexible insulation batt flexcl 5 i Detail: gableboard 4 HOMATHERM holzflex between rafters alternative: HOMATHERM flexcl 5 HOMATHERM holzflex between battens The high-performance rafter insulation. alternative: HOMATHERM flexcl 6 Airtight membrane/vapour barrier (alternative: air-tight wood-based board) 7 Interior facing high-performance, flexible wood-fibre insulation batt optimal thermal and heat protection with large insert widths keeps its shape between rafters and battens high-performance, flexible cellulose insulation batt ideal for high sound insulation requirements keeps its shape between rafters and battens HOMATHERM holzflex HOMATHERM flexcl Optimal summer heat protection Airtight fit to rafters to prevent heat loss Non-irritant installation, healthy living For renovations, use oversize batts and cut to length. holzflex between rafters between under rafters /en/planning Detailed information for roof renovation: /en/roof-renovation /product-information flexcl = W/mK λ between rafters between under rafters 160 0,277 3,80 9, ,277 3,80 9, ,250 4,25 9, ,250 4,25 9, ,228 4,75 10, ,228 4,75 10, ,209 5,20 11, ,209 5,20 11, ,189 5,70 12, ,189 5,70 12, ,175 6,15 13, ,175 6,15 13, ,163 6,65 14, ,163 6,65 14, ,153 7,10 14, ,153 7,10 14,8 PITCHED ROOF 10 11

7 PITCHED ROOF 1 Roof covering 2 Support battens, counter battens recommendations Pitched roof: from inside from inside 3 HOMATHERM UD protect from 35 mm 4 Flexible insulation batt holzflex 5 Compression resistant insulation board USD-Q11 protect HOMATHERM USD-Q11 protect behind the exterior cladding 4 HOMATHERM holzflex between rafters 5 HOMATHERM USD-Q11 protect from 40 mm The high-performance rafter insulation. HOMATHERM UD protect HOMATHERM holzflex HOMATHERM USD-Q11 protect 6 Fibre reinforced reinforcing compound (reinforcing fabric) 7 Fine filler permeable to vapours, can buffer moisture temporarily and release it in a controlled manner fixes securely between rafters, no convection currents in the structural element Compliant with the new fire protection class D-s1-d0 in accordance with EN All-round tongue and groove Hydrophobic throughout Structure from inside to outside: Interior cladding Installation battens with holzflex standard Panelling (OSB) Timber studs with holzflex standard USD-Q11 protect Ventilation Exterior cladding Optimal additional insulation for new buildings and renovations Large heat storage capacity for excellent protection from summer s heat Non-irritant during installation, healthy when in use UD protect λ = W/mK = W/mK Roof under rafters between rafters on rafters /en/planning Detailed information for roof renovation: /en/roof-renovation /product-information holzflex USD-Q11 protect λ = W/mK = W/mK Timber studs, wall between support batten (IE) between timber studs from outside, on timber studs PITCHED ROOF 12 13

8 PITCHED ROOF between rafters for maximum energy efficiency 1 Roof covering 2 Support battens, counter battens 3 HOMATHERM UD protect from 35 mm 4 HOMATHERM finefloc between rafters alternative: between crossbeams recommendations Pitched roof: between rafters for maximum energy efficiency 3 Overlay board UD protect 4 Cellulose flocks finefloc 6 Flexible insulation batt flexcl The economical solution for large insulating es. 5 Air-tight installation of wood-based board 6 Interior facing alternative: service cavity with HOMATHERM flexible insulation batt flexcl stable partitions which keep their shape rainproof and windtight additional insulation 25 % weight reduction, resulting in improved thermal conductivity and easier handling seamless, space-filling section insulation potential savings due to automated transportation and laying high-performance for high sound insulation requirements makes effective use of the cavities behind interior facings can be clamped from a of 30 mm HOMATHERM UD protect HOMATHERM finefloc Economical comb ination with insulation boards above the rafters Thermal protection, heat protection and sound insulation included Installation by certified specialist companies Reduce rafter height to structural requirements, use construction on page 16. finefloc = W/mK λ UD protect λ = W/mK = W/mK finefloc between rafters UD protect on rafters /en/planning Detailed information for roof renovation: /en/roof-renovation /product-information flexcl = W/mK λ flexcl under rafters finefloc between rafters UD protect on rafters ,168 6,45 14, ,170 6,30 14, ,157 6,90 15, ,159 6,75 15, ,147 7,40 16, ,149 7,25 16, ,139 7,85 16, ,141 7,70 16, ,131 8,35 17, ,133 8,15 17, ,125 8,80 18, ,127 8,60 18, ,119 9,30 19, ,121 9,10 18, ,113 9,75 19, ,115 9,55 19,6 PITCHED ROOF 14 15

9 PITCHED ROOF 1 Roof covering 2 Support battens, counter battens recommendations Pitched roof: The effective insulation combination The effective insulation combination 3 Permeable sarking membrane alternative: HOMATHERM UD-Q11 protect 4 Compression resistant insulation board HDP-Q11 standard 5 Flexible insulation batt holzflex i Planning tip 4 HOMATHERM HDP-Q11 standard (large format) 5 HOMATHERM holzflex between rafters Save maximum energy, protect from heat and noise, minimise costs. 6 Airtight membrane/vapour barrier alternative: air-tight interior facing, e. g. wood-based board) 7 Battens 8 Interior facing high-performance insulation made of wood low thermal conductivity for optimal thermal insulation ship-lap edge for seamless laying flexible wood-fibre insulation batt low-cost insulation between rafters stable, seamless insulation Fixing large-format HDP Q11 standard takes place exclusively with double-thread screws HOMATHERM HDP-Q11 standard HOMATHERM holzflex Low-cost high-performance wood insulation Large insulating es can be processed easily with a sabre saw. Create a passive house in just one step Mount insulation without sheathing directly onto the rafters /en/planning Calculation service roof insulation: /product-information holzflex HDP-Q11 protect between rafters on rafters PITCHED ROOF 16 17

10 PITCHED ROOF 1 Roof covering 2 Support battens, counter battens recommendations Pitched roof: The homogeneous on-roof insulation The homogeneous on-roof insulation 3 HOMATHERM UD-Q11 alternative: sarking membrane 3 Overlay board UD protect 4 Compression resistant insulation board HDP-Q11 standard i Detail: chimney penetration 4 HOMATHERM HDP-Q11 standard 5 Airtight membrane/vapour barrier 6 Exposed wood sheathing 7 Exposed rafters pressure-resistant wood fibre insulation board no foil required as underlay wind- and rainproof, can be used as emergency roofing exposed to weather for up to ten weeks low thermal conductivity for optimal thermal insulation single layer up to 240 mm ship-lap edge for seamless laying Low-cost, simple and quick to install. HOMATHERM UD protect HOMATHERM HDP-Q11 standard lay large insulating es in a single layer low-cost high-performance wood insulation pressure-resistant insulation low-cost mounting /en/planning Calculation service roof insulation: /product-information HDP-Q11 standard UD protect λ = W/mK = W/mK on rafters PITCHED ROOF 18 19

11 FLAT ROOF Exterior insulation for residential and industrial buildings 1 Gravel load 2 Waterproofing system 3 HOMATHERM HDP-Q11 protect recommendations Flat roof: Exterior insulation for residential and industrial buildings 4 Compression resistant insulation board HDP-Q11 protect i Reference: Theiner s Garten Bio Vitalhotel 4 Airtight membrane/vapour barrier 5 Exposed sheathing 6 Exposed rafters specially suited for flat roofs also suitable as incline insulation ecological and resource-saving excellent moisture storage properties diffusion-tight waterproofing sheeting can be laid directly on top Photos: baukraft architektur, Brixen (I) Now also in flat roofs with heat protection. HOMATHERM HDP-Q11 protect Ship-lap edge for seamless laying. Extremely pressure-resistant and dimensionally stable Economical: insulate es of up to 240 mm in one step Can also be used as additional insulation against heat and sound in all tested configurations /en/planning /product-information HDP-Q11 protect = W/mK λ on rafters FLAT ROOF 20 21

12 TOP-STOREY CEILING recommendations Top-storey ceiling: Thermal insulation on concrete ceilings Thermal insulation on concrete ceilings 1 HOMATHERM holzflex 1 Flexible insulation batt holzflex Usability/properties HOMATHERM finefloc HOMATHERM holzflex HOMATHERM holzflex / flexcl HOMATHERM HDP-Q11 standard HOMATHERM HDP-Q11 protect cannot be walked on (without covering) 2 Concrete ceiling 3 Rendering single-layer insulation up to 200 mm optimal heat insulation due to = W/(mK) cheapest flexible HOMATHERM insulation batt can only be walked on with beam construction and covering can be walked on without covering, cannot be used in full (surface wear) Low-cost insulation and maximum energy savings. HOMATHERM holzflex can be walked on with covering (floating installation), can be used with restrictions (e. g. as storage surface) can be walked on with covering (floating installation), can be used completely (e. g. as residential space) Easy handling Reusable insulation batts e. g. as roof insulation when converting the loft Strips of HDP-Q11 standard between the insulation batts enable a wood-based board to be positioned for walking on the insulated surface. Can be walked on for assembly and maintenance purposes /en/planning Detailed information top-storey ceiling: /en/top-storey-ceiling /product-information holzflex on concrete ceiling TOP-STOREY CEILING 22 23

13 FLAT TOP-STOREY ROOF #03 CEILING 1 Wood-based board recommendations Top-storey ceiling: against unheated roof space against unheated roof space 2 HOMATHERM HDP-Q11 standard 2 Compression resistant insulation board HDP-Q11 standard 4 Flexible insulation batt holzflex i Saving potential 3 Timber cladding 4 HOMATHERM holzflex between timber beams 5 Airtight membrane/vapour barrier 6 Support battens 7 Interior facing low-cost high-performance wood insulation low thermal conductivity for optimal thermal insulation single layer up to 240 mm ship-lap edge for seamless laying single-layer insulation up to 200 mm optimal heat insulation due to = W/(mK) cheapest flexible HOMATHERM insulation batt With a 3-star insulation system, up to 12 l of heating oil can be saved per m², per year (calculation based on information from: Federal Environment Office). Floor ceiling insulation is a low-cost way of saving energy effectively. The perfect insulation for all seasons. HOMATHERM HDP-Q11 standard HOMATHERM holzflex Save energy and costs also ideal for renovations Q11 insulation boards can be trimmed to size using the HOMATHERM insulation knife. Perfect cold, heat and noise insulation, also for uninsulated roofs Full usability of the roof space with simple ceiling structure /en/planning Detailed information top-storey ceiling: /en/top-storey-ceiling /product-information holzflex HDP-Q11 standard on rafters on beams TOP-STOREY CEILING 24 25

14 TOP-STOREY CEILING recommendations Top-storey ceiling: Pressure-resistant insulation solution for easily accessible roof spaces Pressure-resistant insulation solution 3 Compression resistant insulation board HDP-Q11 protect i Detailed solution 1 Wet screed for easily accessible roof spaces 2 Waterproofing sheeting 3 HOMATHERM HDP-Q11 protect 4 Concrete ceiling 5 Rendering high pressure-resistance of 100 kpa easy-to-handle format (suitable for floor gaps) insulation es of mm ship-lap edge for seamless laying For seamless laying in old buildings on top-storey ceilings, it is advisable to use strips of flexible insulation batts (in full insulation ) as edge insulation strips. Futureproof: Perfect subsurface for future conversion to living space. HOMATHERM HDP-Q11 protect Wet or dry screed can be applied across the whole Trim to size quickly and dust-free with jig saws and serrated knifes. es up to 240 mm can be laid in one layer Can be walked on and used completely /en/planning Detailed information top-storey ceiling: /en/top-storey-ceiling /product-information HDP-Q11 protect = W/mK λ on concrete ceiling TOP-STOREY CEILING 26 27

15 FLAT TOP-STOREY ROOF #03 CEILING recommendations Top-storey ceiling: of difficult-to-access wooden joist ceilings of difficult-to-access 4 Cellulose flocks finefloc i Timber Frame wooden joist ceilings 1 HOMATHERM finefloc 2 Timber beam 3 Timber cladding 4 Rendering on plaster base optimal flow characteristics quick to install machine installation insulation transported and installed in one step Installation carried out exclusively by certified, trained installers. Nominal = 0.8 x installation Quick and easy installation of large insulating es. HOMATHERM finefloc Surface moisture secures the insulation layer. Seamless insulation of open beam s and uneven surfaces Installation by certified specialist Cannot be walked on /en/planning Detailed information top-storey ceiling: /en/top-storey-ceiling /product-information finefloc = W/mK λ on wooden joist ceilings TOP-STOREY CEILING 28 29

16 EXTERNAL WALL recommendations External wall: Façade insulation on masonry Façade insulation on masonry 1 HOMATHERM composite thermal insulation system EnergiePlus massive 1 CTIS EnergiePlus massive 4 Compression resistant insulation board ID-Q11 standard i Numerous system components 2 Adhesive mortar 3 Walling Noise stays outside heat and comfort on the inside. 4 Rendering alternative: HOMATHERM ID-Q11 standard, rendered convenient small format from 100 mm optimal pressure-resistance, therefore impact resistant base board for rendering (without plaster) can be exposed to weather for up to four weeks. can be rendered with loam rendering and other interior plasters moisture-balancing to protect the structure and create a healthy indoor environment ideal for renovations and preservation of historic buildings HOMATHERM offers numerous system components for the EnergiePlus composite thermal insulation system. HOMATHERM composite thermal insulation system EnergiePlus massive Safety and long life for your property Optimal noise protection for residents Approved composite thermal insulation system Details regarding joints between EnergiePlus massive and adjacent structural elements or intersections must be planned very carefully. Later extensions to façades, e. g. exterior lighting (electric cabling etc.), must be taken into account at the planning stage EnergiePlus massive = W/mK λ EnergiePlus massive from outside on masonry (KS) /en/planning Detailed information CTIS: /en/ctis /product-information ID-Q11 standard = W/mK λ ID-Q11 standard from inside on masonry (KS) EnergiePlus massive from outside on masonry (KS) EXTERNAL WALL 30 31

17 EXTERNAL WALL recommendations External wall: Façade insulation on masonry Façade insulation on masonry 1 HOMATHERM composite thermal insulation system 1 CTIS EnergiePlus comfort 2 Flexible insulation batt holzflex 2 Cellulose flocks finefloc EnergiePlus comfort 2 HOMATHERM holzflex s between the supporting structure Low-cost renovation sustainable energy savings. alternative: HOMATHERM finefloc 3 Masonry 4 Rendering optimal pressure-resistance, therefore impact resistant base board for rendering (without render) can be exposed to weather for up to four weeks in es up to 120 mm single-layer insulation up to 200 mm optimal heat insulation due to W/(mK) cheapest flexible HOMATHERM insulation batt rapid installation for large insulating es optimal flow characteristics seamless section insulation HOMATHERM composite thermal insulation system EnergiePlus comfort HOMATHERM holzflex Approved composite thermal insulation system When blowing in HOMATHERM finefloc use base boards for rendering from 60 mm. From 200 mm insulation between the supporting structure, use HO MATHERM finefloc With all the possibilities of an appealing, contempory façade design /en/planning Detailed information CTIS: /en/ctis /product-information holzflex EnergiePlus comfort bis 60 mm: λ = W/mK = W/mK ab 80 mm: = W/mK λ between timber studs on timber studs EXTERNAL WALL 32 33

18 EXTERNAL WALL recommendations External wall: Façade insulation suitable for rendering in timber framing Façade insulation suitable for 1 HOMATHERM composite thermal insulation system EnergiePlus comfort 1 CTIS EnergiePlus comfort 2 Flexible insulation batt holzflex 4 i Numerous system components rendering in timber framing 2 HOMATHERM holzflex between timber studs Insulate without thermal bridges and allowing moisture to diffuse. HOMATHERM composite thermal insulation system EnergiePlus comfort HOMATHERM holzflex Insulates against noise, heat and cold EnergiePlus offers a wide range of design options. The render paint should have a brightness value > Wood-based board, laid air-tight 4 HOMATHERM holzflex between battens (service cavity) 5 Interior facing direct assembly on timber studs insulates across the thermal bridges of the structural supports base board for rendering (without render) can be exposed to weather for up to four weeks single-layer insulation up to 200 mm optimal heat insulation due to cheapest flexible HOMATHERM insulation batt HOMATHERM offers numerous system components for the EnergiePlus composite thermal insulation system High-quality façade for a pleasant living environment Safety and long life for your wooden house Approved composite thermal insulation system holzflex between supporting battens (IE) /en/planning Detailed information CTIS: /en/ctis /product-information EnergiePlus comfort bup to 60 mm: λ = W/mK = W/mK from 80 mm: = W/mK λ between timber studs from outside on timber framing EXTERNAL WALL 34 35

19 EXTERNAL WALL 1 Façade cladding 2 Battens recommendations External wall: Curtain walling on cross laminated timber Curtain walling on cross laminated timber 3 HOMATHERM UD protect 3 Overlay board UD protect 4 Compression resistant insulation board HDP-Q11 standard i Reference: apartment house in solid wood construction alternative: permeable wall formwork sheeting 4 HOMATHERM HDP-Q11 standard Wood insulation on timber structure timber structure throughout. 5 Cross laminated timber wall 6 Interior facing pressure-resistant wood fibre insulation board insulation es mm windproof tongue-andgroove connection waterproofed throughout very good thermal conductivity from 140 mm, seamless laying through shiplap edge insulation es of mm HOMATHERM UD protect HOMATHERM HDP-Q11 standard Insulate without thermal bridges and allowing moisture to diffuse. Cold, heat and sound insulation High-performance insulation made of wood Fix UD protect with adhesive in impact s and joints so that it is wind- and watertight /en/planning Detailed information curtain walling: /en/walling /product-information HDP-Q11 standard UD protect λ = W/mK = W/mK from outside on cross laminated timber wall EXTERNAL WALL 36 37

20 EXTERNAL WALL recommendations External wall: Interior insulation on masonry Interior insulation on masonry 1 Masonry with or without rendering 3 Compression resistant insulation board ID-Q11 standard 3 Flexible insulation batt flexcl i Alternative structure: half-timbered wall 2 Adhesive mortar (reinforcing compound) 3 HOMATHERM ID-Q11 standard Retaining the existing facade is now possible with interior insulation. alternative: HOMATHERM flexcl between the supporting structure 4 Reinforced mineral rendering or loam rendering (alternative: interior facing) can be rendered with loam plaster and other interior plasters moisture-balancing to protect the structure and create a healthy indoor environment ideal for renovations and preservation of historic buildings high-performance, flexible cellulose insulation batt keeps its shape between the supporting structure extremely good moisture regulation in the structural element Structure from the inside out: Plasterboard Vapour barrier sheeting (e. g. Intello, pro clima) HOMATHERM flexible insulation batt flexcl between crossshaped battens Rendering Half-timbered construction, bricked HOMATHERM ID-Q11 standard Saving energy in existing buildings is even possible when preserving historic buildings Healthy and pleasant indoor environment Optimal moisture-balancing due to sorption capacity Simply cut installation channels in the insulation. ID-Q11 standard from inside on masonry /en/planning /product-information flexcl = W/mK λ from inside on masonry 100 0,359 2,35 17, ,359 2,35 17, ,312 2,85 18, ,312 2,85 18, ,276 3,30 19, ,276 3,30 19, ,248 3,80 20, ,248 3,80 20,0 EXTERNAL WALL 38 39

21 BASEMENT CEILING 1 Concrete ceiling recommendations Basement ceiling: Ceiling insulation against unheated basement rooms Ceiling insulation against 2 HOMATHERM ID-Q11 standard 3 Compression resistant insulation board ID-Q11 standard i Potential savings 3 Rendering system unheated basement rooms alternative 1: coating system alternative 2: no cladding Save energy and costs with minimum effort. HOMATHERM ID-Q11 standard can be rendered with loam rendering and other interior plasters insulation boards are fixed in place with adhesive and secured to the ceiling with anchors an appealing look is achieved by rendering the board Installing insulation in an existing basement ceiling can reduce the total heat loss in a building by around 10 %. An insulation of approx. 6 cm. is recommended. Source: Federal Environment Office Thermal insulation Thermal insulation Thermal insulation Perfect heat insulation Quick assembly, no covering required HOMATHERM ID-Q11 standard can be given individual finishes. ID-Q11 standard from below on concrete ceiling Can be rendered for special requirements Which insulation is best for which ceiling? The type of basement ceiling insulation is determined by the requirements of the user, for example: the heat insulation and consequently the insulation appearance effort required for assembly installation Panelling /en/planning Detailed drawings, technical consultation and recommendations for paneling/rendering: /product-information Basement space used as / solution with (processing) Leisure room (e. g. hobby or party basement) Storage room Equipment room (e. g. for building services equipment) ID-Q11 standard ID-Q11 standard Flexible insulation batts stick/anchor/render anchor suspension system BASEMENT CEILING 40 PRODUCT: RECOMMENDED POSSIBLE 41

22 BASEMENT CEILING 1 Concrete ceiling recommendations Basement ceiling: Ceiling insulation against unheated basement rooms Ceiling insulation against unheated basement rooms 2 HOMATHERM holzflex between battens alternative: HOMATHERM flexcl 3 Interior facing 2 Flexible insulation batt holzflex 2 Flexible insulation batt flexcl i Linking tips Funding is available for insulation of the building shell, i.e. including the basement ceiling. Details given online at cost-effective and light optimal heat insulation due to W/(mK) can be clamped from a of 40 mm easy processing compact material structure and excellent absorption properties ensure maximum sound insulation /foerderung The dry wall tape. HOMATHERM holzflex alternative: HOMATHERM flexcl Perfect thermal protection Quick installation and simple levelling of uneven surfaces Simple incorporation of services Use HOMATHERM flexcl between battens in s with higher requirements for acoustic insulation, such as hobby cellars or music rooms. Thermal insulation Thermal insulation Thermal insulation holzflex between timbers cross-shaped battens /en/planning Detailed drawings, technical consultation and recommendations for paneling/rendering: /product-information flexcl = W/mK λ between timbers cross-shaped battens 40 0,782 0, ,782 0, ,595 1, ,595 1, ,480 1, ,480 1, ,403 2, ,403 2, ,471 1, ,471 1, ,339 2, ,339 2,80 BASEMENT CEILING 42 43

23 FLOOR of floors in contact with the earth and unheated basement rooms 1 Floor covering 2 Wet screed (poss. with underfloor heating system) 3 Waterproofing sheeting recommendations Floor: of floors in contact with the earth and unheated basement rooms 4 Compression resistant insulation board HDP-Q11 protect i Detail: structure model with insulation batts and dry screed Perfect heat insulation with comfort factor. 4 HOMATHERM HDP-Q11 protect 5 Waterproofing sheeting 6 Floor slab low thermal conductivity with a high compressive strength of 100 kpa ideal for screed, including with underfloor heating system also suitable for insulating timber beam ceilings Structure from top to bottom: Dry screed (e.g. boards or planking, optional: vapour barrier sheeting) HOMATHERM flexible insulation batts between supporting timbers (optional: laid crosswise) Waterproofing sheeting/floor slab HOMATHERM HDP-Q11 protect Heat insulation and comf ort Ecological: underfloor heating system based on fibreboard. of floors which are cold under foot High pressure resistance and large insulating es Thermal insulation Thermal insulation Thermal insulation /en/planning Detailed drawings, technical consultation and recommendations: /product-information HDP-Q11 protect = W/mK λ on floor slab FLOOR 44 45

24 CEILING of timber beam ceilings 1 Floor covering recommendations Ceiling: of timber beam ceilings 4 Compression resistant insulation board TS-Q11 protect i Ceiling structure from top to bottom Acoustic insulation L n,w : 48 db 2 Wet screed (poss. with underfloor heating system) 3 Waterproofing sheeting 4 HOMATHERM TS-Q11 protect 5 Waterproofing sheeting Low compressibility under higher service load High compressive strength ( 100 kpa) Outstanding acoustic damping properties Dynamic rigidity of 25 MN/m3 only Cellulose insulating batt (e. g. OSB) HOMATHERM TS-Q11 protect Timber cladding HOMATHERM flexcl between timber beams Spring rail Interior facing The whispering ceiling HOMATHERM TS-Q11 protect Optimal footfall and airborne sound insulation for quiet and comf ort Ecological: underfloor heating system based on fibreboard. 6 Floor slab Tested standard footfall sound level L n,w : 48 db Tested airborne sound damping coefficient R w : 64 db Concrete ceiling Without raw ceiling load with dry or wet screed L n,w R w ΔL w Also possible under planking, parquet, carpeting or underfloor heating system Ceiling and floor can be used immediately OSB subfloor board 22 mm, 4-sided tongue & groove HOMATHERM footfall sound insulation boards 31/30 mm Concrete ceiling 180mm 48 db 64 db 21 db OSB subfloor board 22 mm, 4-sided tongue & groove HOMATHERM footfall sound insulation boards 31/30 mm HOMATHERM footfall sound insulation boards 31/30 mm Concrete ceiling 180 mm 45 db 65 db 25 db /en/planning /product-information Verification of sound insulation & fireproofing: Send an to: info@homatherm.com Anhydrite screed 60 mm incl. FBH Sealing HOMATHERM footfall sound insulation board 31/30 mm HOMATHERM footfall sound insulation board 31/30 mm Concrete ceiling 180 mm 43 db 70 db 24 db CEILING 46 47

25 INSIDE WALL 1 Plaster fibre board, double planked recommendations Inside wall: Sound insulation for all interior spaces Sound insulation for all interior spaces 2 HOMATHERM flexcl between metal upright studs alternative: HOMATHERM holzflex 2 Flexible insulation batt flexcl 2 Flexible insulation batt holzflex i Detail: metal double stud wall 3 Plaster fibre board, double planked moulds itself around studs and prevents sound bridges compact material structure and excellent absorption properties ensure maximum sound insulation high-performance insulation batt made of wood keeps its shape sealed joint installation No noise from next door. Airborne sound insulation dimensions R w [db] using Fireproofing HOMATHERM flexcl Structure examples HOMATHERM product HOMATHERM flexcl [db] HOMATHERM holzflex [db] HOMATHERM finefloc [db] Supporting structure Metal stud framing Fire resistance class Perfect sound insulation Quick installation and minimal wastage thanks to adapted formats Wide range of verified sound insulation and fireproofing structures Fireproofing. F30 possible with single-layer planking, 12.5 mm. Install separating wall strip (sponge rubber) for acoustic decoupling. HOMATHERM flexible insulation batts between metal upright studs, double planked Structure: Gypsum fibre 10 mm Gypsum fibre 12.5 mm Metal upright studs with HOMATHERM flexible insulation batt Gypsum fibre 12.5 mm Gypsum fibre 10 mm F 30 B F 30 B F 30 B F 30 B /en/planning Verification of sound insulation & fireproofing: Send an to: info@homatherm.com /product-information HOMATHERM flexible insulation batts between metal upright studs, single planked and double planked Structure: Gypsum fibre 10 mm Gypsum fibre 12.5 mm Metal upright studs with HOMATHERM flexible insulation batt Gypsum fibre 12.5 mm F 30 B F 30 B F 30 B F 30 B INSIDE WALL 48 49

26 INSIDE WALL For s with special ecological requirements 1 Plaster fibre board 2 HOMATHERM holzflex between timber studs recommendations Inside wall: For s with special ecological requirements 2 Flexible insulation batt holzflex 3 Plaster fibre board high-performance insulation batt made of wood keeps its shape sealed joint installation Healthy and pleasant indoor environment. HOMATHERM holzflex Quick installation and minimal wastage Perfect sound insulation Non-irritant during installation, healthy when in use HOMATHERM flexible insulation batts between timber studs with plaster fibre boards Structure examples Structure: Gypsum fibre 10 mm Gypsum fibre 12.5 mm Timber studs with HOMATHERM flexible insulation batt Gypsum fibre 12.5 mm Gypsum fibre 10 mm Airborne sound insulation dimensions R w [db] Fireproofing HOMATHERM product HOMATHERM holzflex / flexcl [db] HOMATHERM finefloc [db] Supporting structure Metal stud framing Fire resistance class x F 30 B x F 30 B x F 30 B x F 30 B x F 30 B /en/planning Verification of sound insulation & fireproofing: Send an to: info@homatherm.com /product-information HOMATHERM flexible insulation batts between timber studs with wood-based boards Structure: Gypsum fibre 10 mm OSB 15 mm Timber studs with HOMATHERM flexible insulation batt Wood-based board 15 mm Gypsum fibre 10 mm x F 30 B x F 30 B x F 30 B x F 30 B x F 30 B INSIDE WALL 50 51

27 APPLICATION OVERVIEW PITCHED ROOF FLAT ROOF TOP-STOREY CEILING EXTERNAL WALL BASEMENT CEILING FLOOR CEILING INSIDE WALL group HOMATHERM product of existing roofs with air-tight interior facing Roof renovation from outside from inside between rafters for maximum energy efficiency The effective insulation combination The homogeneous on-roof insulation Exterior insulation for residential and industrial buildings Thermal insulation on concrete ceilings against unheated roof space Pressureresistant insulation solution for easily accessible roof spaces of difficult-toaccess wooden joist ceilings Façade insulation on masonry Façade insulation on masonry Façade insulation suitable for rendering in timber framing Curtain walling on cross laminated timber Interior insulation on masonry Ceiling insulation against unheated basement rooms Ceiling insulation against unheated basement rooms of floors in contact with the earth and unheated basement rooms of timber beam ceilings Sound insulation for all interior spaces For s with special ecological requirements from page 06 from page 08 from page 10 from page 14 from page 16 from page 18 from page 20 from page 22 from page 24 from page 26 from page 28 from page 30 from page 32 from page 34 from page 36 from page 38 from page 40 from page 42 from page 44 from page 46 from page 48 from page 50 FLEXIBLE BATTS (wood fibre/ cellulose) holzflex flexcl LOOSE INSULATION FLOCKS (cellulose) finefloc COMPRESSION RESISTANT INSULATION BOARDS (wood fibres) UD-Q11 protect USD-Q11 protect HDP-Q11 standard HDP-Q11 protect CTIS EnergiePlus massive CTIS EnergiePlus comfort ID-Q11 standard TS-Q11 protect PRODUCT: RECOMMENDED POSSIBLE APPLICATION OVERVIEW 52 53

28 PRODUCT OVERVIEW Key General technical approval Full declaration Compressive stress with 10 % compression Tensile strength perpendicular to the board plane Short-term water absorption Water vapour diffusion resistance factor Dynamic rigidity (depending on ) Length-based flow resistance Rated value of the thermal conductivity Specific heat capacity Format (nominal length x nominal width) Nominal Fireproofing Fireproofing (Switzerland) Max. short-term working temperature Max. weight E-module (with compressive stress) group HOMATHERM product Unit Unit Unit Unit Unit Unit Unit Unit Unit Unit Unit Unit Unit Unit Unit Unit Unit Unit kpa kpa kg/m 3 MN/m 3 kpa*s/m 2 in W/(mK) (EU) λ (D) (AT) J/(kgK) mm mm Euroclass in accordance with EN Fire code according to VKF (CH) C kg/m 3 N/mm 2 FLEXIBLE INSULATION BATTS (wood fibre/ cellulose) holzflex WF-EN T2 TR1.0-MU3-AFr5 flexcl Z Z ETA 03/0057 Wood fibres, polyolefin fibres, ammonium polyphosphate Cellulose from newspaper, polyolefin fibres, boric acid 5 %, mixture inorganic salts ,039 0,042 0, square: 1220 x 580 square: 1200 x E E 5.3 low flammability, low smoke emission 5.3 low flammability, low smoke emission 100 approx approx. 70 LOOSE INSULATION FLOCKS (cellulose) finefloc Z ETA-12/0474 Cellulose made from newspaper, boric acid 5 %, mixture of inorganic salts E COMPRESSION RESISTANT INSULATION BOARDS (wood fibres) UD protect USD-Q11 protect HDP-Q11 standard HDP-Q11 protect CTIS EnergiePlus massive CTIS EnergiePlus comfort ID-Q11 standard TS-Q11 protect WF-EN T4- CS(10/Y) 200-TR7.5-WS1.0- MU3-AFr100 WF-EN T4- CS(10/Y)100-TR10.0- WS1.0-MU3-AF100 WF-EN T3-CS(10/Y) 20-WS2.0-MU3- AFr100 WF-EN T3-DS(70.-)2- CS(10/Y)100-TR10-WS1.0- MU3-AFr100 WF-EN T4-TR10- CS(10/Y)100-WS1.0-MU3- AFr100 WF-EN T4-TR20- CS(10/Y)100-WS1.0-MU3- AFr100 WF-EN T4-CS(10/Y) 50-TR7.5-WS2.0-MU3- AFr100 WF-EN T6-WS1.0- MU3-AF100-SD25-CP2 Z Z Z Z Z Z (CTIS) Z Z (CTIS) Z Z Wood fibres, PMDI bonding, paraffin Wood fibres, PMDI bonding, paraffin Wood fibres, PMDI bonding, paraffin Wood fibres, PMDI bonding, paraffin Wood fibres, PMDI bonding, paraffin Wood fibres, PMDI bonding, paraffin Wood fibres, PMDI bonding, paraffin Wood fibres, PMDI bonding, paraffin from 80 mm: to 60 mm: tongue-and-groove: 2520 x 610 and 2525 x 615, 1825 x 615 tongue-and-groove: 1825 x 615 square: 1250 x 600 stepped profile: 1265 x x 615 square: 1250 x 600 stepped profile: 1265 x 615 square: 1250 x x 600 tongue-and-groove: 1325 x 615 square: 1250 x 600 square: 1250 x , 35, 52, E 100 approx D 100 approx E 100 approx E 100 approx E 100 approx.160 E 100 approx E 100 approx /30 E PRODUCT OVERVIEW 54 55