HORIZONTAL SLIDER - LARGE MISSILE IMPACT

Size: px
Start display at page:

Download "HORIZONTAL SLIDER - LARGE MISSILE IMPACT"

Transcription

1 HORIZONTL SLIDER - LRGE MISSILE 36" MX. SSH WIDTH GLSS DLO 7 /" WIDTH 7" MX. UNIT WIDTH GENERL NOTES:. THE PRODUCT SHOWN HEREIN IS DESIGNED ND MNUFCTURED TO COMPLY WITH THE FLORID UILDING CODE (FC), CURRENT EDITION ND IS RTED FOR MISSILE LEVEL D USE IN WIND ZONE 3 RES S DEFINED IN STM E 996 PER THE FC. THIS PRODUCT MY NOT E USED IN THE HIGH VELOCITY HURRICNE ZONE (HVHZ) OR IN STM E 996 WIND ZONE RES. 2. GLZING OPTIONS: (SEE 2) 3. CONFIGURTIONS: "XX".. DESIGN PRESSURE RTING: -NEGTIVE DESIGN LODS SED ON, TESTED PRESSURE ND GLSS TLES STM E POSITIVE DESIGN LODS SED ON, TESTED PRESSURE, WTER INFILTRTION TEST PRESSURE ND GLSS TLES STM E /" 63" MX UNIT 8 7/8" MX SSH X X C D. NCHORGE: THE /3% STRESS INCRESE HS NOT EEN USED IN THE DESIGN OF THIS PRODUCT. SEE FOR NCHOR DETILS. WINDLOD DURTION FCTOR Cd=.6 WS USED FOR WOOD NCHOR CLCULTIONS. 6. PRODUCT PPROVED FOR RESISTNCE. SHUTTERS RE NOT REQUIRED. 7. LL FRMES ND VENTS FULLY WELDED. 8. SERIES / MODEL DESIGNTION HS THE DESIGNTION X ND O STND FOR THE FOLLOWING: X = OPERLE SSH GLSS DLO 0. SECTION CLLOUTS PPLY TO LL ELEVTIONS IN SIMILR LOCTION.. EXTERNL WEEP SLOT = /6" x 2-/8" LOCTED -/2" FROM OTH ENDS. 6/8/20 FL PE # 820 PH TLE OF CONTENTS GENERL NOTES & ELEVTIONS... SECTION VIEWS & GLZING...2 EXTRUSIONS &.O.M...3 NCHOR SCHEDULE & NOTES... INSTLLTION DETILS... FRME TYPE FIN MX. UNIT DESIGN PRESSURE RTING SIZE RTING +/- PSF 7" x 63" LRGE MISSILE +/- 0 PSF GENERL NOTES ND ELEVTIONS EMK 0/27/ :2 OF

2 INTERIOR SECTION VIEW - INTERIOR 7/8" OVERLL /8" NNELED 7/6" IRSPCE /6" LMINTED /8" NNELED.090" DUPONT PV INTERLYER /8" NNELED SIKFLEX 2 OR PURFECT GLZE "H" /8" GLSS ITE 6/8/20 FL PE # 820 PH SECTION VIEW - SECTION VIEWS ND GLZING DETIL LTERNTE FIN FRME EMK 0/27/ ITEMS NOT SHOWN FOR CLRITY: 7-8, 0, 2, -6 & 2 GLSS TYPE :2 2 OF

3 PRTS LIST ITEM PRT DESCRIPTION MTERIL VENDOR H-627 MIN FRME PVC TN 2 H-63 SSH INTERLOCK RIL, INT. PNEL PVC TN 3 H-639 SSH DRW RIL PVC TN H-60 SSH TOP/TM RIL PVC TN H-60 SSH INTERLOCK RIL, EXT. PNEL PVC TN 6 P-3028 SETTING LOCK, /8" x 7/8" x 2" FRNK LOWE 7 P-3029 SCREEN LIFT TS STEEL SUMMIT 8 P-30 SCREEN SPRINGS STEEL FL SCREEN 9 P-8 SCREEN FRME LUM FL SCREEN 0 P-28 SCREEN SPLINE DP P-0 WTSP., 0.87" x 0.270" SOFT FIN MESURY 2 P-3 #8-8 x 0.62" PN PH TEK #2 POINT ZP STEEL FSTENL 3 P-3783 SSH LOCK INTERLOCK P-378 KEEPER INTERLOCK P-6 #8-8 x 0.70" FH PH #2 POINT TEK ZP STEEL FSTENL 6 P-7 SCREEN CORNER KEY NYLON FL SCREEN 7 P-0 JUMO WEEP COVER SSY NYLON SHLND 8 P " HOLE PLUG NYLON HEYCO 9 P-3 #8-8 x 0.62" SQ PH TEK #2 POINT ZP STEEL FSTENL 20 P-28 ROLLER SSY MESURY 23 P-36 JM UMPER RUER MINOR RUER 2 P- L LOCK, NTI-LIFT NYLON 26 S-200 REINF., SIDE RIL LUM SCEND 27 S-200 REINF., MEETING RIL, INT. PNEL LUM SCEND 28 S-2029 INTERLOCK DPTOR LUM SCEND 29 S-2030 ROLLER TRCK LUM SCEND 3 S-203 REINF., MEETING RIL, EXT. PNEL LUM KEYMRK S-20 REINF., TOP/OTTOM RIL LUM SCEND S " GLZING ED PVC TN 3 GLSS SEE 2 3 DOW CORNING 99 SILICONE 36 PURFECT GLZE "H", SIKFLEX 2 SILICONE HENKEL / SIK LINE ITEMS NOT USED: 2-22, 2, 30 /8" /6" PVC MIN FRME - H-627 PVC TOP/TM RIL - H-60 PVC INTERLOCK RIL - H-63 /6" " /8" 3 2 /6" /6" /2" PVC DRW RIL /8" /6" LUM REINF. - S-203 LUM REINF. - S-20 LUM REINF. - S /6" 3/6" LUM INTERLOCK - S-2029 /6".093" CORNER CONSTRUCTION.00" /6" CORNER WELD LL SIDES :8 PVC GLZING ED - S-6 /6" LUM REINF. - S-200 /6" 26 /8" 9/6" 29 LUM ROLLER TRCK - S " /2" 3/" 2 6/8/20 FL PE # 820 PH OM ND EXTRUSIONS NOTE: LL EXTRUSIONS RE LUMINUM 6063-T6 UNLESS OTHERWISE NOTED. /2" OPERLE PNEL NTI-LIFT P- EMK 0/27/ :2 3 OF

4 6" MX. (TYP.) 6" MX. (TYP.) 8" MX. O.C. (TYP.) LC " (TYP.) " (TYP.) SEE NOTE 2 INSTLLTION NCHOR (TYP.) 8" MX O.C. (TYP.) " MX. (TYP.) " MX. (TYP.) 8" MX. O.C. (TYP.) X X X X LC " THRU FRME NCHOR (TYP.) SEE NOTE 2 INSTLLTION NCHOR (TYP.) NCHOR LYOUT - () NCHOR LYOUT - (FIN) NOTE THRU FRME MTG RIL NOTES:. INSTLL ONE NCHOR T ECH INSTLLTION LOCTION. SILL NCHOR SPCING SME S HED. 2. SHIM S REQ T ECH INSTLLTION NCHOR USING LOD ERING SHIMS. MX. LLOWLE SHIM STCK TO E /". USE SHIMS WHERE SPCE GRETER THN IS PRESENT. LOD ERING SHIMS SHLL E CONSTRUCTED OF HIGH DENSITY PLSTIC OR ETTER. WOOD SHIMS RE NOT LLOWED. 3. NCHOR TYPE, SIZE, SPCING ND EMEDMENT SHLL E S SPECIFIED IN THESE DRWINGS,,.. LL INSTLLTION NCHORS MUST E MDE OF OR PROTECTED WITH CORROSION RESISTNT MTERIL OR COTING. DISSIMILR METLS OR MTERILS IN CONTCT WITH PRESSURE TRETED WOOD MUST E PROTECTED TO PREVENT RECTION.. INSTLLTION NCHORS SHLL E IN CCORDNCE WITH NCHOR MNUFCTURER'S INSTLLTION INSTRUCTIONS, ND NCHORS SHLL NOT E USED IN SUSTRTES WITH STRENGTHS LESS THN THE MINIMUM SPECIFIED IN TLE,. 6. NCHOR EMEDMENT TO SUSTRTE SHLL E EYOND WLL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMEDMENT SHLL E EYOND WOOD UCKS, IF USED, INTO SUSTRTE. INSTLLTIONS INTO SOLID CONCRETE OR GROUT-FILLED CMU MY INCLUDE UT DO NOT REQUIRE X WOOD UCKS ETWEEN THE PRODUCT ND SUSTRTE. INSTLLTIONS INTO HOLLOW CMU REQUIRE THE USE OF X WOOD UCKS ETWEEN THE PRODUCT ND SUSTRTE. 7. MINIMUM CENTER-TO-CENTER SPCING SHLL E MINTINED ETWEEN LL FSTENERS: 3-9/6" FOR MSONRY, " FOR WOOD ND METL. 8. WOOD OR MSONRY OPENINGS, UCKS ND UCK FSTENERS SHLL E PROPERLY DESIGNED Y THE RCHITECT OR ENGINEER OF RECORD ND INSTLLED TO TRNSFER WIND LODS TO THE STRUCTURE. SUSTRTES SHLL MEET THE MINIMUM STRENGTH REQUIREMENTS S SHOWN IN TLE,. CONCRETE ND MSONRY SUSTRTES MY NOT E CRCKED. 9. SELING ND FLSHING STRTEGIES FOR OVERLL WTER RESISTNCE OF INSTLLTION SHLL E DONE Y OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FM/M 00(FIN WINDOWS), FM/M 200( WINDOWS), FM/WDM 20(OX WINDOWS), FM/M/WDM 300(EXTERIOR DOORS) FL PE # 820 PH NCHOR SCHEDULE ND NOTES EMK 0/27/ :20 6/8/20 OF

5 SUSTRTE Y OTHERS SELNT EHIND TYPICL HED NCHORGE /" MX. SHIM /" MX. SHIM INSTLLTION NCHOR SUSTRTE Y OTHERS /" MX. SHIM SUSTRTE Y OTHERS INSTLLTION NCHOR HORIZONTL SECTION TYPICL JM NCHORGE SELNT EHIND C INSTLLTION NCHOR SELNT EHIND FIN HORIZONTL SECTION TYPICL FIN NCHORGE HED ND SILL SIMILR FOR FIN INSTLLTION NOTE: DDITIONL THRU-FRME NCHORS (S SHOWN IN DET. /) REQ'D T MTG RIL, SEE NCHOR LYOUT. SELNT EHIND /" MX. SHIM SUSTRTE Y OTHERS SELNT UNDER SCREW HED VERTICL SECTION TYPICL SILL NCHORGE FRME TYPE SUSTRTE TYPE NCHOR TYPE CONCRETE (2.0 KSI MIN.) 3/6" ITW TPCON " -/8" HOLLOW OR GROUT-FILLED CMU (7 PCF MIN.) 3/6" ITW TPCON " 2" CONCRETE (2.8 KSI MIN.) 3/6" ELCO ULTRCON " " GROUT-FILLED CMU (STM C-90) 3/6" ELCO ULTRCON -3/" 2-/2" 2X MIN. SOUTHERN PINE (G=0.) 3/6" ITW TPCON OR ELCO ULTRCON -3/8" 7/8" 2X MIN. SOUTHERN PINE (G=0.) #0 WOOD SCREW -3/8" 7/8" 6 GUGE (0.060") MIN. STEEL STUD ( KSI YIELD MIN) /8" LUM. (6063-T MIN.) OR /8" STEEL ( KSI MIN.) TLE : PPROVED INSTLLTION FSTENERS #0-6 HILTI KWIK-FLEX OR ITW TEKS SELF-DRILLING SCREW #0 GRDE SELF-TPPING / DRILLING SCREW FULL THRED THRU 0.060" FULL THRED THRU 0.2" FIN 2X MIN. SOUTHERN PINE (G=0.) #0 WOOD SCREW -/2" /2" 7/6" 7/6" D HORIZONTL SECTION OX FRME INSTLLTION SIMILR FOR HED ND SILL FOR OX INSTLLTION REMOVL NOTE: PRTILLY OR FULLY REMOVING THE, UP TO ND INCLUDING OX-FRME PPLICTION IS CCEPTLE PROVIDED: - MIN. /" FILLET OF CONSTRUCTION-GRDE DHESIVE CULK IS PPLIED, FULL PERIMETER,. - PRODUCT NCHORGE IS IN CCORDNCE WITH REQUIREMENTS S SHOWN FOR WINDOWS. FL PE # 820 PH INSTLLTION DETILS EMK 0/27/ :2 6/8/20 OF