Drawing List FLOOR PLAN EXISTING / DEMO NEW FLOOR PLAN ELEVATIONS / SECTIONS RATED ASSEMBLIES PENETRATION DETAILS LIGHTING / POWER DIST.

Size: px
Start display at page:

Download "Drawing List FLOOR PLAN EXISTING / DEMO NEW FLOOR PLAN ELEVATIONS / SECTIONS RATED ASSEMBLIES PENETRATION DETAILS LIGHTING / POWER DIST."

Transcription

1 8//05 :55:44 PM HILLSDALE, MI A000 A0 A0 A00 A0 E00 M00 P00 Sheet Number BUILDING DATA PERMITTING JURISDICTION CITY OF HILLSDALE PROPERTY ZONING B DOWNTOWN BUSINESS (LEVEL 0) BUILDING CODE 0 MICHIGAN REHAB CODE MECHANICAL CODE 0 MICHIGAN MECHANICAL CODE ELECTRICAL CODE 0 NEC PLUMBING CODE 0 MICHIGAN PLUMBING CODE NEW CONSTRUCTION TYPE TYPE 5B BUILDING USE B/R (PER LEVEL REMODELED ONLY) SPRINKLED NO (0 MICHIGAN REHAB CODE SECTION EXEMPTIONS AND ) PROJECT ENGINEER: RICHARD C. MORAN, P.E. MORAN ENGINEERING SERVICES LLC 440 WOODLAND TERRACE BROOKLYN, MI 4930 PHONE: FAX (57) LICENSE # 4557 Drawing List Sheet Name COVER SHEET FLOOR PLAN EXISTING / DEMO NEW FLOOR PLAN ELEVATIONS / SECTIONS RATED ASSEMBLIES PENETRATION DETAILS LIGHTING / POWER DIST. HVAC PLUMBING DOWNTOWN HILLSDALE, MICHIGAN ARCH SYMBOL LEGEND A0 0 SIM CALLOUT TAG 60 N HOWELL. INDICATES CENTER LINE DOOR TAG NUMBER? Room name KEYNOTE ROOM NAME WITH ROOM NUMBER EXISTING PROJECT GENERAL NOTES DEMOLITION NOTES FIELD VERIFY CONDITIONS PRIOR TO START OF DEMOLITION/CONSTRUCTION, AND NOTIFY THE PROJECT ENGINEER OF ANY DISCREPANCIES. CONFORM TO ALL BUILDING CODES AND EXECUTE WORK ONLY ICH IS IN CONFORMANCE PROTECT ALL EXISTING PORTIONS OF THE EXISTING BUILDING TO REMAIN DURING DEMOLITION/ CONSTRUCTION. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ANY/ALL DAMAGES CAUSED BY HIMSELF OR HIS/HERS SUBCONTRACTORS KEEP CLEAN ALL EXISTING SPACES AND PROPERTIES ADJACENT TO DEMOLITION/CONSTRUCTION AREAS. ANY DEBRIS SHALL BE REMOVED FROM WORK AREAS DAILY. IF REQUIRED CLOSE OFF EXISTING SPLY/RETURN PIPES FEEDING EXISTING ROOMS TO PREVENT DUST/DEBRIS ENTRY EXISTING COMMERCIAL SPACE ON LEVEL REMAINS UNCHANGED View Name /8" = '0" i SECTION VIEW WITH NUMBER AND SHEET ELEVATION MARK VIEW TITLE WITH SCALE WALL TAG No. Description NEW CONSTRUCTION NOTES ALL NEW CONSTRUCTION TO BE COMPLIANT WITH ALL CURRENT APPLICABLE LOCAL, STATE, AND FEDERAL BUILDING CODES. BECAUSE THIS IS A REMODEL PROJECT VARATIONS WILL OCCUR AS NEW CONDITIONS ARE DISCOVERED. THESE PLANS ARE NOT AN EXACT REPRESENTATION OF A FINISHED PROJECT, BUT A VISUAL GUIDE. BUILDER MUST VERIFY ALL DIMENSIONS PRIOR TO ANY CONSTRUCTION AND MAKE ANY ADJUSTMENTS / CHECK WITH PROJECT ENGINEER AS NECESSARY THIS IS A DESIGN BUILD PROJECT. PLEASE CONSULT WITH THE PROJECT ENGINEER DURING CONSTRUCTION IF NEEDED. t WINDOW TAG STRUCTURAL EXISTING FLOOR SYSTEMS TO REMAIN. EXISTING STAIRWELL ENTRY FROM EAST AND WEST TO REMAIN. EXISTING ROOF SYSTEM TO REMAIN WALL CONSTRUCTION AS DRAWN ON FLOOR PLANS UNLESS NOTED OTHERWISE, ALL FRAMING LUMBER TO BE SPF# OR BETTER. a. INTERIOR WALLS ARE: 3/" WITH ONE LAYER /" GWB ON EACH SIDE UNLESS OTHERWISE NOTED FLOOR COVERING ALL FLOOR COVERINGS SPECIFIED BY OWNER/CONTRACTOR WALL/CEILING COVERINGS/FINISHES ALL WALLS UNLESS OTHERWISE SPECIFIED TO HAVE /" DRYWALL FINISH WITH PRIMED AND PAINTED SURFACE TYP. COLOR (SPECIFIED BY OWNER) BATHROOM WALLS AROUND TUBS TO HAVE /" MR BOARD INSTALLED PER MANUFACTURER SPEC. OTHER MASONRY WALLS TO BE REFINISHED W/ WOOD FURRING / /" GWB PAINTED FINISH. REPAIR WALLS WITH MORTAR (TYP) IF ANY CRACKS/HOLES PRESENT. ALL MASONRY WALLS (EXCEPT THE SOUTH AND EAST WALLS IN THE LARGE ROOM IN UNIT 3) TO BE FULLY FURRED AND ENERGY EFFICIENT. HOLES IN PER FLOOR MASONRY WALL TO BE PATCHED W/MORTAR (TYP) EXISTING PER FLOOR CEILING TO REMAIN (EXISTING PER CORRIDOR CEILING REPLACED WITH H RATED ASSEMBLY) (REFINISH AND PATCH AS REQUIRED) / A0 0 NORTH ARROW VIEW REFERENCE COLUMN GRID MARKER INTERIOR ELEVATION WITH VIEW NUMBER / SHEET TRIMS PROVIDE 0" TYP PAINTED FINISH BASE TRIM (SPECIFIED BY OWNER) PROVIDE.5" DOOR AND WINDOW CASING PAINTED (SPECIFIED BY OWNER) TRIM SHALL BE MDF PRIMED EXCEPT FOR BATHROOMS ICH WILL BE SOLID WOOD KITCHEN FINAL KITCHEN DESIGN BY OTHERS. CABINET TYPE (SPECIFIED BY OWNER) COUNTERTOPS TO BE SPECIFIED BY OWNER APPLIANCES SPECIFIED BY OTHERS DOORS ALL DOORS TO BE SPECIFIED BY CONTRACTOR ALL DOOR HARDWARE TO BE SPECIFIED BY CONTRACTOR ENTRY DOOR TO STAIRWELL FROM EXTERIOR TO BE SPECIFIED BY CONTRACTOR AREA LEVEL (EXISTING COMMERCIAL) (NO CHANGES TO LEVEL ) (N/A) S.F. APARTMENT RENOVATIONS AREA APARTMENT (NO CHANGES) 763 S.F. APARTMENT,30 S.F. APARTMENT 3,663 S.F. COVER SHEET NEW WINDOWS ALL EXISTING WINDOWS TO BE REPLACED. VERIFY ALL WINDOW LOCATIONS AND SIZES. NEW WINDOWS SPECIFIED BY CONTRACTOR AT LEAST ONE EXISTING WINDOW OPENING IN EACH UNIT TO BE CONVERTED TO AN EGRESS WINDOW NATURAL GAS SPLY EACH UNIT TO HAVE NEW NATURAL GAS LINES RUN FROM EXISTING MAIN CONNECTION INTO BUILDING. CONTRACTOR TO DETERMINE PROPER ROUTE. FIRE ALARMS FIRE/SMOKE ALARM SYSTEM TO BE INSTALLED FOR RENOVATED AREAS PER CODE STAIRS AND RAILING NEW WOOD FRAMED STAIRS TO HAVE A 7" RISER AND AN " RUN. ALL NEW RAILING TO BE MIN. 4" A.F.F. HOUR FIRE SEPARATION FLOOR/CEILING ASSEMBLY EXISTING FLOOR REMOVED AND REPLACED WITH SYSTEM #3 AS NOTED ON SHEET A00 EXISTING LOWER FLOOR CEILING DECORATIVE TIN TO BE COATED WITH 'FIRE FREE 88' HOUR RATED PAINT. SEE SHEET A00 FOR DETAILS / SPECIFICATIONS GROSS RENOVATED AREA GROSS AREA LEVEL 3,78 S.F. 4,069 S.F.S.F. A000

2 8//05 :55:45 PM 6 EXISTING ROOF REMOVED 0' 5" 7' 0 3/4" 8' 0" 8' 4" 3' 9 /4" 6' 0" 4' 3" 3' 5" APARTMENT (NO CHANGES) (733 S.F.) 5 6' 3' 0" No. Description 4 0' 8" LEVEL DEMOLITION EXISTING STAIRS COVERED WALL LEGEND POURED CONCRETE WALL WOOD STUD WALL WITH GWB BOTH SIDES INDICATES EXISTING MASONRY WALL FLOOR PLAN EXISTING / DEMO PARTITION WALL TO BE REMOVED EXISTING WOOD FRAMED WALL TO REMAIN WOOD STUD WALL W/ACCUOSTIC INSULATION WOOD STUD WALL WITH HOUR ASSEMBLY (WILL HAVE KEYNOTE) A0 WALL TYPES 3/8" = '0"

3 8//05 :55:45 PM WALL LEGEND WALL TYPES 3/8" = '0" POURED CONCRETE WALL WOOD STUD WALL WITH GWB BOTH SIDES INDICATES EXISTING MASONRY WALL PARTITION WALL TO BE REMOVED EXISTING WOOD FRAMED WALL TO REMAIN WOOD STUD WALL W/ACCUOSTIC INSULATION WOOD STUD WALL WITH HOUR ASSEMBLY (WILL HAVE KEYNOTE) ' 8" 7' 8 /4" 7' 8 /" ' ' 7 5/8" 5' 0" 5' 0 5/8" 4' 3/8" 9' /4" 88' /" EXISTING STAIRS TO REMAIN 5' 0" 5' /8" 6 WOOD FRAMED LANDING 50' 5/8" WOOD FRAMED STAIRS 3' 6 7/8" 7' 0" 9' 6 3/4" 4' 8 3/8" 9' " 4' 5/8" 3' 6 7/8" ' 8" 5' 0" NEW RAILING MIN 4" HIGH EXISTING WINDOWS REMOVED AND REPLACED WITH AT LEASE ONE EGRESS OPERATING WINDOW IN EACH UNIT EXISTING DOORS REPLACED 3' 4 /8" 4' 3 7/8" 4' 0" 4' 0" ' 3 /4" 7' 0" 5' 4" 3' 0 /8" 9' 0 5/8" 4' 0" 5' 0" PROVIDE HR FLOOR L56 (SHEET A00) FLOOR CEILING ASSEMBLY 5' 0" 7' 0" ' APARTMENT 3' 4 /4" 3' 3/4" 4' /8" 5 ' 7 /4" ' 8" 6' " 7' 0 3/4" 4' 0" NEW STACKABLE W/D 3' 7/8" ' 0 /8" ' 3/4" EXISTING ROOF LANTERNS TO BE RESTORED 4' 5/8" ' 8" 6' 0" 3' 8" 6' 0 5/8" 7' 0 /8" SHOWER 9' 0" 6' /" SHOWER ' 8" 3 Elevation a APARTMENT (NO CHANGES) (733 S.F.) 7' /4" 9' 4" 7' 7" 9' " ' " ' 5 /8" 6' 5 7/8" NEW STACKABLE W/D USE EXISTING PLUMBING LAYER 5/8" C CORE CEILING GWB W/WOOD FRAMING PROVIDE HR WALL CORRIDOR WALLS AND CEILING, AS WELL AS ALL UNIT SEPARATION WALLS L34 (SHEET A00) LAYER 5/8" C CORE CEILING GWB W/WOOD FRAMING 7' 3 3/8" 6' /4" Elevation b 7 7' 6 /4" 4 Elevation c 8" RAISED PLATFORM 0' 8 /" EXISTING DOOR REPLACED WITH A 60 MIN FIRE RATED DOOR/FRAME PROVIDE ONE LAYER 5/8" TYPE 'C' CORE DRYWALL TAPED AND FINISHED FOR A HR RATING. WALLS AND CEILING OF EXISTING STAIRS APARTMENT 3 ' 7/8" 8' 3/4" 6' " 6' 3" ' 3/8" 8' 5 3/4" 8' /4" ' 0 7/8" 49' 5 7/8" No. Description NEW FLOOR PLAN 0' 3 5/8" 9' /4" 9' 4 7/8" 39' 3 7/8" A0

4 8//05 :55:46 PM EXISTING CONDENSORS TO BE MOVED TO PROVIDE MIN 3 CLEARANCE AND CLEARANCE FROM NEW STAIR POSTS EXISTING OPENING IN RETAINING WALL 6 0' 0 /4" 3' 4" 0' 0 /4" NEW CONCRETE STEP 6X6 TREATED POST WITH SIMPSON OR APPROVED POST STANDOFF W/ "" CONCRETE FILLED SONOTUBE MIN. 4" BELOW GRADE 6X6 TREATED POST WITH SIMPSON OR APPROVED POST STANDOFF W/ "" CONCRETE FILLED SONOTUBE MIN. 4" BELOW GRADE 3' 9 /" 3' NEW CONCRETE STEP ' 7" 7' 8 3/8" 3' 3 /" TREATED LVL LEDGER BOARD FOR LANDING JOISTS BOLTED TO EXISTING MASONRY WALL 7 Elevation b 3' 8 /8" 4 CEILING ' " ' 4" CABINETS BY OWNER 4 Section 4 /" = '0" 0' 7 /4" COUNTERTOP BY OWNER 3/4" OSB SUBFLOORING X8 WOOD FRAMED PLATFORM EXISTING FLOOR SYSTEM W/ HARDWOOD FLOORING ' 4" NEW WOOD FRAMED STAIRS 7' 0" 4' 7" CEILING ' " LEVEL EXISTING 3/8" = '0" EXISTING SLOPED ROOF TO HAVE WOOD FRAMED DECK TREATED X4 SLEEPERS 4" O.C. 5/4 TREATED DECKING PROVIDE NEW 4" RAILING ALONG EDGE OF DECK AREA 0' 0" 0' 8 /4" 7' 0" ' 4" No. Description NEW TREATED WOOD FRAMED STAIRS 3 Elevation a 4" RAILING SPECIFIED BY OWNER EXISTING RETAINING WALL ' 4" 7' NEW CONCRETE STEP 3' 0 /" 7' 7 7/8" 7' 6 /8" CEILING ' " 5' 0" not used 4 03' 0" 3' 9 3/8" X4 CEILING JOISTS ROOF LANTERN NEW TRIM BY OWNER 6 Section 6 CEILING ' " 0' 0" ELEVATIONS / SECTIONS ' 4" 5 Section 5 Elevation c ' 4"

5 UL DESIGN FOR SECOND FLOOR FLOORING SYSTEM (HR) FF88 RATED PAINT /" = '0" DESIGN NO. L5 System No. 3 (FEB. 6 05) Subflooring Min 5/3 in. thick wood structural panels, min grade "CD" or "Sheathing". Face grain of plywood or strength ais of panels to be perpendicular to the joists with joints staggered. Vapor Barrier (Optional) Nom 0.00 in. thick commercial rosinsized building paper. Finish Flooring Min 9/3 in. wood structural panels, min grade "Underlayment" or "Single Floor". Face grain of plywood or strength ais of panels to be perpendicular to joists with joints staggered. RATED ASSEMBLIES A00 /" = '0" U34 /" = '0" 4 Description FC09 /" = '0" 3 8//05 :55:48 PM No.

6 Description No. PENETRATION DETAILS Author A0 /" = '0" PENETRATION DETAILS /" = '0" 8//05 :55:49 PM

7 8//05 :55:50 PM 8" 4" ELECTRICAL SYMBOLS LEGEND ELECTRICAL PANEL RECESSED CAN LIGHT 8" RECESSED CAN LIGHT FLOURESCENT SHOP LIGHT ' LIGHT FLOURESCENT SHOP LIGHT 4' LIGHT FLOURESCENT SHOP LIGHT 8' LIGHT WALL HUNG FIXTURE CEILING PENDANT CEILING FIXTURE WALL MOUNTED EXIT SIGN / EMERGENCY LIGHT W/BATTERY BACK 4" RECESSED CAN LIGHT CEILING FAN/LIGHT R D 3 DLEX RECEPTACLE DLEX 48" A.F.F. DLEX GROUND FAULT INTERRTER (GFI) DLEX GROUND FAULT INTERRTER 48" A.F.F. QUADRLEX RECEPTACLE QUADRLEX 48" A.F.F. QUADRLEX GROUND FAULT INTERRTER (GFI) QUADRLEX GROUND FAULT INTERRTER 48" A.F.F. DLEX 0 DEDICATED CIRCUIT SWITCH DIMMER SWITCH TWO WAY SWITCH SINGLE SWITCH THREE WAY PANEL SCHEDULES E TRACK LIGHTING FIXTURES WITH AN E DESIGNATES EMERGENCY BATTERY BACK OR WIRED FOR EMERGENCY SERVICE. FLOOR DLEX RECEPTACLE W/COVER ELECTRICAL SYMBOL LEGEND ELECTRICAL NOTES ALL ELECTRICAL FIXTURES SPECIFIED BY OWNER/CONTRACTOR ELECTRICAL WORK TO EXISTING BUILDING TO BE DESIGN BUILD, ALL ELECTRICAL WORK TO CONFORM TO 00 NEC. ANY CHANGES TO BE APPROVED WITH THE PROJECT ENGINEER. ALL NEW INTERIORTO BE CONNECTED TO BUILDING MDP EMERGENCY WALL PACKS W/ BATTER B/U No. Description LOW VOLTAGE ELECTRICAL NOTES PROVIDE CABLE AND PHONE CONECTIONS FOR ALL UNITS PROVIDE SMOKE AND CARBON MONOXIDE DETECTORS AS REQUIRED ELECTRICAL NOTES DECK LIGHTING BY OWNER LIGHTING / POWER DIST. LEVEL ELECTRICAL 3/ = '0" E00

8 8//05 :55:5 PM HVAC SYMBOLS LEGEND FD 4X6 ROUND DUCT SPLY 4X6 WALL GRILLE F FURNACE AND SCHEDULE REFERENCE T HVAC SYMBOLS BATH FAN DIRECTION / DUCT SIZE REDUCED THERMOSTAT NEW SPLY DUCT NEW RETURN DUCT FIRE/SMOKE DAMPER 0X6 SPLY GRILLE HVAC EQUIPMENT LIST SPIRAL DUCT VENT, N/A, LINESET TO ROOF GOODMAN EQUIPMENT F GMH950703B FURNACE CC CAPF3636B CASED COIL CU GSX3036 CONDENSOR SG HART AND COOLEY #66 W/6 DAMPER RG 4X4 INTAKE HART AND COOLEY FILTER AND GRILLE THERMOSTAT TSTAT G5 EF 70CFM VENT TO ROOF HVAC EQUIPMENT T No. Description HVAC LEVEL HVAC Author Checker M00 HVAC TO BE SUBMITTED AT A LATER TIME

9 8//05 :55:5 PM PLUMBING GENERAL NOTES FIELD VERIFY ALL SANITARY DRAIN DROPS ERE CONNECTED TO PLUMBING ON LOWER LEVEL NORTH EXISTING 3/4" WATER SPLY TO SPLY EXISTING UNIT, AND ALSO REMODELED UNIT SOUTH 3/4" WATER SPLY TO SPLY EXISTING LOWER COMMERCIAL SPACE AND PER UNIT 3 WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES ALL MATERIALS TO BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S AND/OR TRADE ASSOCIATIONS RECOMMENDATIONS & SPECIFICATIONS CONNECT VENT LINES FROM NEW FIXTURES TO EXISTING, REPAIR AS NECESSARY THIS IS A DESIGN BUILD PROJECT. ALL CHANGES MADE DURING CONSTRUCTION MUST BE APPROVED THROUGH PROJECT ENGINEER PLUMBING GENERAL NOTES PLUMBING SYMBOLS CW HW PLUMBING SYMBOLS EXISTING SANITARY DRAIN NEW SANITARY DRAIN FLOOR DRAIN TYP COLD WATER SPLY NEW HOT WATER SPLY NEW PLUMBING FIXTURE SCHEDULE TAG ITEM MANUFACTURER MODEL PIPE CONNECTION SIZES CW HW WASTE COMMENTS HW AOSMITH ATI540HN 3/4" 3/4" USE EXISTING WATER SPLY WC WATER CLOSET OR APPROVED EQUAL 479CL /" 3".6GPF TWO PIECE FLOOR MOUNT TU SHOWER OR APPROVED EQUAL /" /" " TYPICAL FBG TUB SHOWER UNIT PLUMBING FIXTURE SCHEDULE No. Description PLUMBING Author LEVEL PLUMBING P00