A3.01 OUTDOOR WALKWAY STORAGE 1525 WOMEN CLASSROOM 1526 MEN 1520E STORAGE EXAM CLASSROOM 1521A CLASSROOM STORAGE OUTDOOR WALKWAY A3.

Size: px
Start display at page:

Download "A3.01 OUTDOOR WALKWAY STORAGE 1525 WOMEN CLASSROOM 1526 MEN 1520E STORAGE EXAM CLASSROOM 1521A CLASSROOM STORAGE OUTDOOR WALKWAY A3."

Transcription

1

2 1 A3.01 GENERAL SHEET NOTES B 1522-A 1522A 1524 CONFERENCE DUCT SHAFT 1508 ELECT./ JAN. 1521B 1521A LEVEL 2 KEY PLAN 2 1/8" = 1'-0" 1526 MEN 1520E STORAGE STORAGE 1 A WOMEN 3 EXAM STORAGE A 4 TYP. A1.01 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE 2013 C.B.C. AND ADOPTED AMENDMENTS. ALL ACOUSTICAL CEILING SYSTEM WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE 2013 C.B.C. & DSA IR (REV ) - METAL SUSPENSION SYSTEMS FOR LAY-IN PANEL CEILINGS. REFER TO INSTALLATION DETAILS AND STANDARDS ON SHEET. SUMMARY SCOPE OF ARCHITECTURAL WORK: BASE BID: REPLACE (E) WINDOWS AND SLIDING DOORS WITH (N) FIXED WINDOWS AND SPANDRELS AT S 1503A, 1505, 1506A D, AND BREAK ROOM 1507 (LOW-E INSULATED GLASS; INSULATED SPANDRELS; THERMAL BREAK FRAMES); REFER TO SHEETS A3.01,, AND THE SPECIFICATIONS. REMOVE AND REPLACE ACOUSTIC CEILING PANELS AT AREAS INDICATED FOR LEVELS 1 AND 2; REFER TO SHEETS A1.02,, AND THE SPECIFICATIONS. PROVIDE (N) FURRING, INSULATION, VAPOR BARRIER, PAINTED GYPSUM BOARD FINISH, AND RESILIENT BASE AT WEST AND SOUTH WALLS OF LEVEL A. FURRED ASSEMBLY SHALL EXTEND ABOVE CEILING & OVER WINDOWS TO UNDER- SIDE OF STRUCTURE ABOVE; REFER TO SHEETS A3.01,, AND THE SPECIFICATIONS. REMOVE AND REPLACE ACOUSTIC CEILING GRID ONLY AS REQUIRED TO ACCOMMODATE (N) FURRING AT LEVEL A; REFER TO SHEETS A1.02,, AND THE SPECIFICATIONS. ADDITIVE ALTERNATE A: REMOVE AND REPLACE ACOUSTIC CEILING GRID AT AREAS INDICATED FOR LEVELS 1 AND 2; REFER TO SHEETS A4.01,, AND THE SPECIFICATIONS. ADDITIVE ALTERNATE B: PROVIDE (N) FURRING, INSULATION, VAPOR BARRIER, PAINTED GYPSUM BOARD FINISH, AND RESILIENT BASE AT NORTH WALLS OF LEVEL 1 S 1505 & 1506A-1506D. FURRED ASSEMBLY SHALL EXTEND ABOVE CEILING & OVER WINDOWS TO UNDER- SIDE OF STRUCTURE ABOVE; REFER TO SHEETS A3.01,, AND THE SPECIFICATIONS. REMOVE AND REPLACE ACOUSTIC CEILING GRID ONLY AS REQUIRED TO ACCOMMODATE (N) FURRING AT LEVEL 1 NORTH S 1505 & 1506A-1506D; REFER TO SHEETS A1.02,, AND THE SPECIFICATIONS. BASE BID & ADDITIVE ALTERNATES: CEILING SYSTEMS SHALL BE INSTALLED AT HEIGHTS MATCHING EXISTING. ALL DIMENSIONS TO FINISH FACE UNLESS OTHERWISE NOTED. ALL NEW FURING TO BE 2 X 4 24" O.C. RIPPED TO DIMENSION OF INSULATION PANEL THICKENESS W/ 5/8" GYP. SIDES, U.O.N. GENERAL CONTRACTOR SHALL COORDINATE WITH ALL TRADES INVOLVED TO ENSURE CLEARANCES FOR FIXTURES, DUCTS, CEILINGS, ETC. NECESSARY TO MAINTAIN THE SPECIFIED FINISH CEILING HEIGHT ABOVE THE FINISH FLOOR SLAB AS NOTED ON THE DRAWINGS. REVIEW CONFLICTS WITH ARCHITECT. CEILING GRID REFRAMING CHANGES DUE TO CEILING CONFLICTS MUST BE APPROVED BY COLLEGE REPRESENTATIVE. GENERAL CONTRACTOR SHALL PROVIDE PROTECTION TO ALL EXISTING FINISHES IN PUBLIC CORRIDORS AND EXISTING FINISHED SPACES DESIGNATED TO REMAIN AND SHALL BE RESPONSIBLE TO REPAIR ANY DAMAGE CAUSED BY THE CONTRACTOR OR BY ITS SUBCONTRACTORS. REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL DEMOLITION RELATED TO CEILING DEMOLITION. REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF SMOKE ALARMS, FIRE & LIFE SAFETY STROBE LIGHTS / SPEAKERS, AND ELECTIRCAL & LIGHTING-RELATED WORK. REFER TO MECHANICAL DRAWINGS FOR HVAC & PLUMBING DEMOLITION RELATED TO CEILING DEMOLITION. REFER TO MECHANICAL DRAWINGS FOR PLUMBING & HVAC- RELATED WORK NUMBERED SHEET NOTES SUBCONSULTANT CABRILLO COLLEGE GLASS Associates, Inc. a r c h i t e c t u r e & p l a n n i n g BUILDINGS 1400 & 1500 HVAC & LIGHTING RENOVATIONS 300 Lakeside Drive, Suite 1081 Oakland, CA T GLASS Associates, Inc. architecture & planning BUILDING 1500 KEY PLANS & ARCHITECTURAL SCOPE BOILER 1509 PLAY ROOM 1512 OBSERVATION A W 5 ANTE ROOM STOR. 2 A3.01 S 1503B 1503 ENTRY 1502 TODDLER DROP OFF 1503C 1504A 1500A STORAGE 1504B 1501A OBSERVATION ELECT. JAN. 1505B W RESTROOM A 1506B 1506C 1506D CORRIDOR 1505A M RESTROOM 1500 PRESCHOOL PRESCHOOL KITCHEN 1500C OBSER- VATION 1508B MAIL ROOM 1507 BREAK 2 A C COPY 1508A RECEPTION 4 TYP REFER TO ELECTRICAL DRAWINGS FOR LIGHTING DEMOLITION AND REPLACEMENT REFER TO MECHANICAL DRAWINGS FOR HVAC & PLUMBING DEMOLITION AND MODIFICATIONS. (N) FIXED WINDOWS AND SPANDRELS TO REPLACE (E) WINDOWS AND SLIDING S 1503A, 1505, 1506A D, AND BREAK ROOM 1507; REFER TO SHEETS A3.01,, AND THE SPECIFICATIONS. AREAS OF ACOUSTICAL CEILING SYSTEM WORK SHOWN SHADED; REFER TO GENERAL SHEET NOTES, LEGEND, SHEETS A1.02,, AND THE SPECIFICATIONS. (N) FURRING, INSULATION, VAPOR BARRIER, PAINTED GYPSUM BOARD FINISH, AND RESILIENT BASE AT WEST AND SOUTH WALLS OF LEVEL A. FURRED ASSEMBLY SHALL EXTEND ABOVE CEILING & OVER WINDOWS TO UNDERSIDE OF STRUCTURE ABOVE; REFER TO SHEETS A3.01,, AND THE SPECIFICATIONS. ADDITIVE ALTERNATE B: (N) FURRING, INSULATION, VAPOR BARRIER, PAINTED GYPSUM BOARD FINISH, AND RESILIENT BASE AT NORTH WALLS OF LEVEL 1 S 1505 & 1506A-1506D. FURRED ASSEMBLY SHALL EXTEND ABOVE CEILING & OVER WINDOWS TO UNDERSIDE OF STRUCTURE ABOVE; REFER TO SHEETS A3.01,, AND THE SPECIFICATIONS. PLAN LEGEND (E) STRUCTURE / PARTITION TO REMAIN (N) FULL-HEIGHT INSULATED FURRING ISSUANCES & REVISIONS NO. DATE DESCRIPTION - 12/21/15 ISSUED FOR DSA REVIEW (N) CEILING-HEIGHT WINDOW WALL W/ INSULATED SPANDREL NAP TODDLER 1 WINDOW KEY; SEE SHEET A3.01 SHADED AREAS INDICATE LOCATIONS OF ACOUSTICAL CEILING SYSTEMS WORK REF. N STAMP FILE NO. 44-C1 IDENTIFICATION STAMP DIV. OF THE STATE ARCHITECT OF REGULATION SERVICES DISCLAIMER THE DATA SET FORTH ON THIS SHEET IS THE PROPERTY OF YOUNG ENGINEERING SERVICES. IT IS AN INSTRUMENT OF SERVICE AND MAY NOT BE ALTERED, REPRODUCED OR USED WITHOUT THE CONSENT OF YOUNG ENGINEERING SERVICES. THE PROPER TRANSFER OF DATA HEREIN, ELECTRONICALLY OR OTHERWISE, SHALL BE THE RESPONSIBILITY OF THE USER WITHOUT LIABILITY TO YOUNG ENGINEERING SERVICES. UNAUTHORIZED USE IS PROHIBITED. LEVEL 1 KEY PLAN 1 1/8" = 1'-0" A1.01 AC: FLS SS DATE: SHEET NO. A1.01

3 1 2 3 REFLECTED CEILING PLAN NOTES B 1522-A 1522A 1524 CONFERENCE DUCT SHAFT 1508 ELECT./ JAN. 1521B 1521A LEVEL 2 REFLECTED CEILING PLAN 2 1/8" = 1'-0" 1526 MEN 1520E STORAGE STORAGE WOMEN EXAM STORAGE 1520A A1.02 1) 2) 3) 4) 5) 6) 7) 8) EXHAUST-AIR REGISTER; SEE MECHANICAL ILLUMINATED EXIT SIGN; SEE ELECTRICAL ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE 2013 C.B.C. & DSA IR (REV ) - METAL SUSPENSION SYSTEMS FOR LAY-IN PANEL CEILINGS. REFER TO INSTALLATION DETAILS AND STANDARDS ON SHEET. ACOUSTICAL CEILING SYSTEM WORK: BASE BID: REMOVE AND REPLACE ACOUSTIC CEILING PANELS AT AREAS INDICATED FOR LEVELS 1 AND 2. REMOVE AND REPLACED ACOUSTIC CEILING GRID ONLY AS REQUIRED TO ACCOMMODATE (N) FURRING AT LEVEL A. ADDITIVE ALTERNATE A: REMOVE AND REPLACE ACOUSTIC CEILING GRID AT AREAS INDICATED FOR LEVELS 1 AND 2. ADDITIVE ALTERNATE B: REMOVE AND REPLACED ACOUSTIC CEILING GRID ONLY AS REQUIRED TO ACCOMMODATE (N) FURRING AT LEVEL 1 NORTH S 1505 & 1506A-1506D. BASE BID & ADDITIVE ALTERNATES: CEILING SYSTEMS SHALL BE INSTALLED AT HEIGHTS MATCHING EXISTING. NO CEILING REMOVAL OR REPLACEMENT WORK AT ANY OTHER LOCATIONS SHALL BE CONDUCTED BY THE CONTRACTOR WITHOUT APPROVAL OF THE DIVISION OF THE STATE ARCHITECT (DSA). GENERAL CONTRACTOR SHALL COORDINATE WITH ALL TRADES INVOLVED TO ENSURE CLEARANCES FOR FIXTURES, DUCTS, CEILINGS, ETC. NECESSARY TO MAINTAIN THE SPECIFIED FINISH CEILING HEIGHT ABOVE THE FINISH FLOOR SLAB AS NOTED ON THE DRAWINGS. REVIEW CONFLICTS WITH ARCHITECT. CEILING GRID REFRAMING CHANGES DUE TO CEILING CONFLICTS MUST BE APPROVED BY COLLEGE REPRESENTATIVE. GENERAL CONTRACTOR SHALL PROVIDE PROTECTION TO ALL EXISTING FINISHES IN PUBLIC CORRIDORS AND EXISTING FINISHED SPACES DESIGNATED TO REMAIN AND SHALL BE RESPONSIBLE TO REPAIR ANY DAMAGE CAUSED BY THE CONTRACTOR OR BY ITS SUBCONTRACTORS. REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL DEMOLITION RELATED TO CEILING DEMOLITION. REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF SMOKE ALARMS, FIRE & LIFE SAFETY STROBE LIGHTS / SPEAKERS, AND ELECTIRCAL & LIGHTING-RELATED WORK. REFER TO MECHANICAL DRAWINGS FOR HVAC & PLUMBING DEMOLITION RELATED TO CEILING DEMOLITION. REFER TO MECHANICAL DRAWINGS FOR PLUMBING & HVAC- RELATED WORK REFLECTED CEILING PLAN LEGEND SUPPLY AIR LINEAR SLOT DIFFUSER; SEE MECHANICAL (N) 2 x 4 LIGHTING FIXTURE; SEE ELECTICAL (N) 2' X 4' AC CEILING GRID CEILING HEIGHT TO MATCH (E) SUBCONSULTANT CABRILLO COLLEGE GLASS Associates, Inc. a r c h i t e c t u r e & p l a n n i n g BUILDINGS 1400 & 1500 HVAC & LIGHTING RENOVATIONS 300 Lakeside Drive, Suite 1081 Oakland, CA T GLASS Associates, Inc. architecture & planning BUILDING 1500 REFLECTED CEILING PLANS & NOTES 1503A 1503B 1503C 1504A 1504B ELECT. JAN A 1506B 1506C 1506D 1507 BREAK 1508C COPY RETURN-AIR REGISTER; SEE MECHANICAL SUPPLY AIR DIFFUSER; SEE MECHANICAL SHADED AREAS INDICATE LOCATIONS OF ACOUSTICAL CEILING SYSTEMS WORK CORRIDOR 1500A STORAGE 1505B W RESTROOM 1505A M RESTROOM PRESCHOOL KITCHEN 1509 PLAY ROOM 1512 OBSERVATION ANTE ROOM STOR ENTRY 1502 TODDLER DROP OFF 1501A OBSERVATION 1500 PRESCHOOL 1500C OBSER- VATION 1508B MAIL ROOM A RECEPTION NUMBERED SHEET NOTES AREAS OF ACOUSTICAL CEILING SYSTEM WORK SHOWN SHADED; REFER TO REFLECTED CEILING PLAN NOTES AND LEGEND. REFER TO ELECTRICAL DRAWINGS FOR LIGHTING DEMOLITION AND REPLACEMENT REFER TO MECHANICAL DRAWINGS FOR HVAC & PLUMBING DEMOLITION AND MODIFICATIONS. ISSUANCES & REVISIONS NO. DATE DESCRIPTION - 12/21/15 ISSUED FOR DSA REVIEW BOILER TODDLER NAP 1 REF. N STAMP FILE NO. 44-C1 IDENTIFICATION STAMP DIV. OF THE STATE ARCHITECT OF REGULATION SERVICES DISCLAIMER THE DATA SET FORTH ON THIS SHEET IS THE PROPERTY OF YOUNG ENGINEERING SERVICES. IT IS AN INSTRUMENT OF SERVICE AND MAY NOT BE ALTERED, REPRODUCED OR USED WITHOUT THE CONSENT OF YOUNG ENGINEERING SERVICES. THE PROPER TRANSFER OF DATA HEREIN, ELECTRONICALLY OR OTHERWISE, SHALL BE THE RESPONSIBILITY OF THE USER WITHOUT LIABILITY TO YOUNG ENGINEERING SERVICES. UNAUTHORIZED USE IS PROHIBITED. LEVEL 1 REFLECTED CEILING PLAN 1 1/8" = 1'-0" A1.02 AC: FLS SS DATE: SHEET NO. A1.02

4 SIM. AT WEST ELEV - RM 1503A 1 1 ELEVATION & WINDOW SHEET NOTES 1) 2) 3) 4) 5) 6) 7) THESE SHEET NOTES INCLUDE BOTH GENERAL AND SPECIFIC SCOPE ITEMS. SPECIFIC ITEMS ARE KEYED IN THE DRAWING TO ASSIST CONTRACTOR IN IDENTIFYING LOCATION OF WORK. NOTES NOT KEYED IN THE DRAWING SHOULD BE CONSIDERED AS GENERAL OR TYPICAL AND APPLY TO ALL AREAS OF THE WORK. REFER TO SHEET G2.04 FOR DOOR SWING CLEARANCES REQUIRED FOR ACCESSIBILITY REFER TO SHEETS A1.01 FOR PLAN INFORMATION & SCOPE OF WORK NOTES. REFER TO SHEETS A1.02 FOR REFLECTED CEILING PLANS. REFER TO SHEETS FOR CONSTRUCTION DETAILS INFORMATION. ALL FINISH MATERIALS SHALL MEET APPLICABLE FIRE AND SAFETY REQUIREMENTS OF CBC FIELD MEASURE ALL WINDOW OPENINGS PRIOR TO FABRICATION OF NEW WINDOWS. NUMBERED SHEET NOTES SUBCONSULTANT GLASS Associates, Inc. a r c h i t e c t u r e & p l a n n i n g 300 Lakeside Drive, Suite 1081 Oakland, CA T GLASS Associates, Inc. architecture & planning NORTH BUILDING ELEVATION 1 1/8" = 1'-0" 1503A 3 1/4" = 1'-0" ELEV. UNDERSIDE OF STRUCTURE ABOVE FIN. FLOOR; CONTRACTOR TO VERIFY IN FIELD ELEV. CLG. ABOVE FIN. FLOOR & HEIGHT OF WINDOW WALL; CONTRACTOR TO VERIFY IN FIELD 13'-5" - V.I.F. A '-3" - V.I.F NORTH WALL INTERIOR ELEVATIONS - LEVEL 1 2 1/4" = 1'-0" FLOOR TO CEILING PARTITIONS TYP. BETWEEN S SEE 15 RESIL. BASE, TYP. S SOUTH WEST A 1506B 1506C 1506D BREAK ROOM 1507 TYP TYP., SEE A3.01 A (N) FIXED WINDOWS AND SPANDRELS TO REPLACE (E) WINDOWS AND SLIDING S 1503A, 1505, 1506A D, AND BREAK ROOM 1507; REFER TO SHEET, AND THE SPECIFI- CATIONS. (N) FURRING, INSULATION, VAPOR BARRIER, PAINTED GYPSUM BOARD FINISH, AND RESILIENT BASE AT WEST AND SOUTH WALLS OF LEVEL A. FURRED ASSEMBLY SHALL EXTEND ABOVE CEILING & OVER WINDOWS TO UNDERSIDE OF STRUCTURE ABOVE (SHOWN HATCHED); REFER TO, AND THE SPECIFICATIONS. ADDITIVE ALTERNATE B: (N) FURRING, INSULATION, VAPOR BARRIER, PAINTED GYPSUM BOARD FINISH, AND RESILIENT BASE AT NORTH WALLS OF LEVEL 1 S 1505 & 1506A-1506D. FURRED ASSEMBLY SHALL EXTEND ABOVE CEILING & OVER WINDOWS TO UNDERSIDE OF STRUCTURE ABOVE (SHOWN HATCHED); REFER TO SHEETS, AND THE SPECIFICATIONS. CABRILLO COLLEGE BUILDINGS 1400 & 1500 HVAC & LIGHTING RENOVATIONS BUILDING 1500 EXTERIOR & INTERIOR ELEVATIONS AND WINDOW TYPES 3'-5" (NOM.) 3'-8" (NOM.) 6'-0" (NOM.) 7 V.I.F. 7 V.I.F. 7 V.I.F. EQ. EQ ISSUANCES & REVISIONS NO. DATE DESCRIPTION - 12/21/15 ISSUED FOR DSA REVIEW '-11" 10'-3" - VERIFY IN FIELD INSULATED TEMPERED GLASS LITES, TYPICAL '-2" 4" 14 INSULATED SPANDREL, LOWER PANEL STAMP WINDOW TYPES 4 1/2" = 1'-0" A3.01 FILE NO. 44-C1 IDENTIFICATION STAMP DIV. OF THE STATE ARCHITECT OF REGULATION SERVICES DISCLAIMER THE DATA SET FORTH ON THIS SHEET IS THE PROPERTY OF YOUNG ENGINEERING SERVICES. IT IS AN INSTRUMENT OF SERVICE AND MAY NOT BE ALTERED, REPRODUCED OR USED WITHOUT THE CONSENT OF YOUNG ENGINEERING SERVICES. THE PROPER TRANSFER OF DATA HEREIN, ELECTRONICALLY OR OTHERWISE, SHALL BE THE RESPONSIBILITY OF THE USER WITHOUT LIABILITY TO YOUNG ENGINEERING SERVICES. UNAUTHORIZED USE IS PROHIBITED. AC: FLS SS DATE: SHEET NO. A3.01

5 FURRED WALL DETAILS WINDOW WALL DETAILS CEILING DETAILS SECURE FURRING STRIPS TO C.M.U. W/ 1/4" FLAT HEAD SCREWS INTO EXPAN. 12" O.C. VERT. ALUM. STOREFRONT W/ INSULATED GLASS LITES AND THERMAL BREAKS; SEE SPECS. CAULK & BACKER ROD O.D. 2 1/4" 1/4" WEB AS OCCURS WOOD BOTTOM CHORD NOTE: SADDLE TIE HAS DOUBLE SUPPORT COMPRESSION STRUT 12 GA. BRACING WIRE W/ MIN. (4) TIGHT TURNS IN 1-1/2" BOTH ENDS OF WIRE CONNECTED TO MAIN TUNNERS, TYP. NOTE: SEE DETAILS THIS SHEET FOR CONNECTIONS OF BRACING & HANGER WIRE TO STRUCTURE ABOVE. GLASS Associates, Inc. a r c h i t e c t u r e & p l a n n i n g PLAN FURRED WALL 6" = 1'-0" 5/8" GYP. BD. O/ 1-1/2" WOOD FURRING 24" O.C. W/ RIGID INSULATION O/ (E) C.M.U. EXTERIOR WALL; ALUM. VAPOR RETARDER ON ROOM SIDE & CONTINUOUS ACROSS FURRING STRIPS; FLOOR TO STRUCTURE; RIP 2x FURRING STRIPS TO MATCH DIMENS. OF RIGID INSULATION; SEE SPECS. 15 JAMB 6" = 1'-0" CAULK & BACKER ROD O.D. 12 HEAD 6" = 1'-0" 4 1/2" 5" ALUM. STOREFRONT W/ INSULATED GLASS LITES AND THERMAL BREAKS; SEE SPECS. 7 BRACING & HANGER WIRE TRUSS CHORD N.T.S. HANGER WIRE; SEE SADDLE TIE DET. BRACE WIRE; SEE SADDLE TIE DET. HANGER WIRES (3) TIGHT TURNS & BRACING WIRES (4) TIGHT TURNS TYP. DETAIL AT TRUSS JOIST TYP. SADDLE TIE DETAIL AT TRUSS JOIST 4 CROSS RUNNER MAIN RUNNER 2" MAX. FROM BRACING WIRES TO COMPRESSION STRUT AND CROSS RUNNER 45º MAX., TYP. ACOUST'L CLG. GRID ATTACHMENT NOTE: REFER TO ELECTRICAL DRAWINGS FOR BRACING OF LUMINAIRES. 45º MAX., TYP. 12 GA. VERTICAL HANGER 4'-0" EA. WAY (4'-0" O.C. AT MAIN RUNNER) MINIMUM (3) TIGHT TURNS IN 3" BOTH ENDS, TYP. N.T.S Lakeside Drive, Suite 1081 Oakland, CA T GLASS Associates, Inc. architecture & planning FURRED WALL BASE 6" = 1'-0" 5/8" GYP. BD. O/ RIGID INSULATION O/ (E) C.M.U. EXTERIOR WALL RESIL. BASE 4" 16 1/16" REVEAL, TYP. ALUMINUM TRANSOM PANEL O/ RIGID INSUL'N; SECURE TO FRAME W/ CONCEALED CLIPS; ALUM. VAPOR RE- TARDER ON ROOM SIDE ALUMINUM TRANSOM PANEL SET IN GLAZING ADAPTER VERTICAL MULLION 6" = 1'-0" CAULK & BACKER ROD JAMB 2" O.D. ALUM. STOREFRONT W/ INSULATED GLASS LITES AND THERMAL BREAKS; HEAVY-DUTY SECTION AT VERTICAL MULLION; SEE SPECS. 13 ALUM. STOREFRONT W/ INSULATED GLASS LITES AND THERMAL BREAKS; SEE SPECS. ALUMINUM TRANSOM PANEL O/ RIGID INSUL'N; SECURE TO FRAME W/ CONCEALED CLIPS; ALUM. VAPOR RE- TARDER ON ROOM SIDE ALUMINUM TRANSOM PANEL SET IN GLAZING ADAPTER 14 VERTICAL MULLION 6" = 1'-0" 6" = 1'-0" 6" = 1'-0" 2" HORIZONTAL MULLION 2" 4 1/2" ALUM. STOREFRONT W/ INSULATED GLASS LITES AND THERMAL BREAKS; HEAVY-DUTY SECTION AT VERTICAL MULLION; SEE SPECS. 8 ALUM. STOREFRONT W/ INSULATED GLASS LITES AND THERMAL BREAKS; SEE SPECS. 9 BRACING & HANGER WIRE 2x & 4x FLOOR & ROOF FRAMING N.T.S. 2 x 6 BLOXCKING FULL WIDTH BETWEEN TRUSS JOISTS AT ROOF DECK; 1/4" DIA. X 2" LAG INTO WD. BLOCK'G INLAID ACCUSTIC PANEL COMPRESSION STRUT N.T.S. HANGER WIRE; TO EYE-HOOK WOOD 2x OR 4x FLOOR OR ROOF JOIST AS OCCURS BRACE WIRE TO EYE HOOK 2" MAX. 1/2"D x 1-1/4" No. 4 G.S.M. EYEHOOK; HANGER WIRES (3) TIGHT TURNS & BRACING WIRES (4) TIGHT TURNS 5 COMPRESSION STRUT FOR EVERY 80 S.F. OF CEILING W/ 10'-0" MAX. SPAN (USE 1/2" EMT FOR LENGTHS TO 3'-9"; USE 3/4" EMT FOR LENTHS 3'-9" TO 5'-0"; USE 1 1/2" EMT FOR LENTHS 5'-0" TO 10'-0") #12 GA. G.S. WIRE SPLAY 4 WAYS; 45 DEG. TO HORIZ., WIRES TO BE PARALLEL TO " " RUNNER 1/4" DIA. M.B. 6 HANGER WIRE ATTACHMENT TO GRID N.T.S. 8" MAX. MAIN RUNNER OR 1/4 OF LENGTH OF END RUNNER, WHICHEVER IS LESS. ACOUSTIC PANEL SPACERS MAY BE SLOTTED ANGLES OR CHANNELS W/ "DIAMOND POINTS" OF SPRING STEEL WHICH SNAP TIGHT TO PREVENT MOVEMENT OF STRUT ALTERNATE SPREADER STRUT 12 GA. HANGER WIRE (3) TIGHT TURNS IN 3" MAX. ALTERNATE LOCATION W/OUT NAIL; NOTCHING PERMITTED ONLY AT RUNNER MAIN OR CROSS RUNNER 12 GA. HANGER WIRE (3) TIGHT TURNS IN 3" MAX. CROSS RUNNER CHANNEL 8" MAX. 2 OR 1/4 OF LENGTH OF END RUNNER, WHICHEVER IS LESS. 3/4" CABRILLO COLLEGE BUILDINGS 1400 & 1500 HVAC & LIGHTING RENOVATIONS BUILDING 1500 ARCHITECTURAL DETAILS ALUM. STOREFRONT W/ INSULATED GLASS LITES AND THERMAL BREAKS; SEE SPECS. WALL ANGLE ACOUSTIC PANEL POP RIVET; SEE NOTE 1) BELOW WALL CONNECTION - ANCHOR TO STRUCTURAL ELEMENT SLOTTED ANGLE SPACER W/ HORIZ. 6D RINGSHANK NAIL; (2) NAILS AT THE END OF HORIZONTAL STRUTS ARE TO BE PLACED WITH NAIL HEAD TOWARD CENTERLINE OF SPAN OF STRUT. ALUMINUM TRANSOM PANEL SET IN GLAZING ADAPTER HORIZONTAL MULLION 6" = 1'-0" 2" 4 1/2" 1/16" REVEAL ALUMINUM TRANSOM PANEL O/ RIGID INSUL'N; SECURE TO FRAME W/ CONCEALED CLIPS; ALUM. VAPOR RE- TARDER ON ROOM SIDE 10 CEILING HANGER HORIZ. STRUT & CONNECTION TO PERIM. N.T.S. NOTES: 1) IR SEC. 3.3: CEILING GRID MEMBERS SHALL BE ATTACHED TO TWO (2) ADJACENT WALLS PER ASTM E580, SECTION CEILING GRID MEMBERS SHALL BE AT LEAST 3/4 INCH CLEAR OF OTHER WALLS. IF WALLS RUN DIAGONALLY TO CEILING GRID SYSTEM RUNNERS, ONE END OF MAIN AND CROSS RUNNERS SHOULD BE FREE, AND A MINIMUM OF 3/4 INCH CLEAR OF WALL. 3 ALUMINUM TRANSOM PANEL SET IN GLAZING ADAPTER ALUMINUM TRANSOM PANEL O/ RIGID INSUL'N; SECURE TO FRAME W/ CONCEALED CLIPS CAULK & BACKER ROD, TYP. 2 1/4" 1/16" REVEAL ALUM. STOREFRONT W/ THERMAL BREAKS; SEE SPECS. RESIL. BASE O.D. 4" ALUM. BOX SECTION W/ THERMAL BREAKS; SEE SPECS. FILE NO. 44-C1 IDENTIFICATION STAMP DIV. OF THE STATE ARCHITECT OF REGULATION SERVICES THE DATA SET FORTH ON THIS SHEET IS THE PROPERTY OF YOUNG ENGINEERING SERVICES. IT IS AN INSTRUMENT OF SERVICE AND MAY NOT BE ALTERED, REPRODUCED OR USED WITHOUT THE CONSENT OF YOUNG ENGINEERING SERVICES. THE PROPER TRANSFER OF DATA HEREIN, ELECTRONICALLY OR OTHERWISE, SHALL BE THE RESPONSIBILITY OF THE USER WITHOUT LIABILITY TO YOUNG ENGINEERING SERVICES. UNAUTHORIZED USE IS PROHIBITED. SILL 6" = 1'-0" 11 AC: FLS SS DATE:

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28 PRIME DESIGN GROUP ELECTRICAL ENGINEERING SINCE POTRERO ST. SUITE SANTA CRUZ, CA PHONE: (831) FAX: (831) PDG PROJECT NO.: CABRILLO COLLEGE BUILDINGS 1400 & 1500 HVAC & LIGHTING RENOVATIONS B FIRST FLOOR LIGHTING PLAN - DEMOLITION B FIRST FLOOR LIGHTING PLAN - DEMOLITION N 1 4 "=1'-0" GENERAL NOTES: SHEET NOTES: FILE NO. 44-C1 IDENTIFICATION STAMP DIV. OF THE STATE ARCHITECT OF REGULATION SERVICES xx-xxxx AC: FLS SS DATE: E2.3

29 PRIME DESIGN GROUP ELECTRICAL ENGINEERING SINCE POTRERO ST. SUITE SANTA CRUZ, CA PHONE: (831) FAX: (831) PDG PROJECT NO.: ELECT JAN CONFERENCE 1520A MEN WOMEN B 1522-A 1522A DUCT SHAFT 1521B 1520E STORAGE 1521A EXAM STORAGE 1520 CABRILLO COLLEGE BUILDINGS 1400 & 1500 HVAC & LIGHTING RENOVATIONS B SECOND FLOOR LIGHTING PLAN - DEMOLITION B SECOND FLOOR LIGHTING PLAN - DEMOLITION N 1 4 "=1'-0" GENERAL NOTES: SHEET NOTES: FILE NO. 44-C1 IDENTIFICATION STAMP DIV. OF THE STATE ARCHITECT OF REGULATION SERVICES xx-xxxx AC: FLS SS DATE: E2.4

30 PRIME DESIGN GROUP ELECTRICAL ENGINEERING SINCE POTRERO ST. SUITE SANTA CRUZ, CA PHONE: (831) FAX: (831) PDG PROJECT NO.: CABRILLO COLLEGE BUILDINGS 1400 & 1500 HVAC & LIGHTING RENOVATIONS B FIRST FLOOR LIGHTING PLAN - NEW WORK B FIRST FLOOR LIGHTING PLAN - NEW WORK N 1 4 "=1'-0" NOTE: ALL FIXTURES ON THIS SHEET ARE NEW AND TYPE 'A', U.O.N. SHEET NOTES: GENERAL NOTES: FILE NO. 44-C1 IDENTIFICATION STAMP DIV. OF THE STATE ARCHITECT OF REGULATION SERVICES xx-xxxx AC: FLS SS DATE: E2.5

31 PRIME DESIGN GROUP ELECTRICAL ENGINEERING SINCE POTRERO ST. SUITE SANTA CRUZ, CA PHONE: (831) FAX: (831) PDG PROJECT NO.: ELECT JAN CONFERENCE 1520A MEN WOMEN B 1522-A 1522A DUCT SHAFT 1521B 1520E STORAGE 1521A EXAM STORAGE 1520 CABRILLO COLLEGE BUILDINGS 1400 & 1500 HVAC & LIGHTING RENOVATIONS B SECOND FLOOR LIGHTING PLAN - NEW WORK B SECOND FLOOR LIGHTING PLAN - NEW WORK N 1 4 "=1'-0" NOTE: ALL FIXTURES ON THIS SHEET ARE NEW AND TYPE 'A', U.O.N. GENERAL NOTES: SHEET NOTES: FILE NO. 44-C1 IDENTIFICATION STAMP DIV. OF THE STATE ARCHITECT OF REGULATION SERVICES xx-xxxx AC: FLS SS DATE: E2.6