Carico Home Inspection Services

Size: px
Start display at page:

Download "Carico Home Inspection Services"

Transcription

1 Page 1 of 24 Table of Contents Definitions 2 General Information 2 Lots and Grounds 3 Exterior 4 Roof 5 Garage/Carport 6 Electrical 6 Structure 7 Attic 7 Basement 9 Air Conditioning 10 Heating System 10 Plumbing 11 Bathroom 12 Kitchen 14 Bedroom 14 Living Space 15 Laundry Room/Area 16 Summary 17

2 Page 2 of 24 Definitions NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection A Acceptable Functional with no obvious signs of defect. NP Not Present Item not present or not found. NI Not Inspected Item was unable to be inspected for safety reasons or due to lack of power, inaccessible, or disconnected at time of inspection. M Marginal Item is not fully functional and requires repair or servicing. D Defective Item needs immediate repair or replacement. It is unable to perform its intended function. General Information Property Information Property Address City Yourtown State US Zip Contact Name Ima Goodagent Phone (111) Client Information Client Name Client Address 3212 Homestead Dr. City Somewhere State OH Zip Phone (333) buyer@usedhouse.com Inspection Company Inspector Name Cliff Carico Company Name Address 123 Somewhere Street City Somewhere State US Zip Phone info@palm-tech.com Conditions Others Present Buyer's Agent and Buyer Property Occupied Occupied Estimated Age 55 Years Old Entrance Faces East Inspection Date 01/06/2014 Electric On Yes No Not Applicable Gas/Oil On Yes No Not Applicable Water On Yes No Not Applicable Temperature 75 degrees Weather Partly cloudy Soil Conditions Damp Space Below Grade Partial basement Building Type Single family Garage Attached Sewage Disposal City How Verified Multiple Listing Service Water Source City How Verified Multiple Listing Service

3 Page 3 of 24 Lots and Grounds This is the disclaimer section. Each category has a disclaimer section. In this section you can include any relevant text for the category. Common uses for this area include: standards of practice, what the inspector does/does not inspect, general information that the client may find helpful, etc. There is no limit to the amount of information that is included in the section. It can be a few words or a few pages worth of information. You can also change the color and the font of the text. Driveway: Concrete Walks: Concrete Cracks noted, Heaving at walk at rear 3 season storm door Cracks in Rear Walk Steps/Stoops: Concrete Porch: Concrete Loose handrail Patio/Enclosure: Ceramic tile, Brick, Aluminum windows Loose limestone wall caps, Missing screens and some cranks, Lubricate as required Missing Cranks Grading: Minor slope Vegetation: Trees, Shrubs

4 Page 4 of 24 Exterior Partial perimeter Exterior Surface Type: Brick/Block Partial perimeter Exterior Surface Type: Vinyl siding Trim: Aluminum Missing piece at front 1 1 Fascia: Aluminum Soffits: Vinyl Door Bell: Hard wired Entry Doors: Metal Patio Door: Vinyl sliding Windows: Vinyl slider Storm Windows: Window Screens: Vinyl mesh Basement Windows: Glass block Exterior Lighting: Surface mount Loose can grill at rear soffit lighting 1 1 Exterior Electric Outlets: 110 VAC GFCI Hose Bibs: Gate Damaged handle needs replaced 1 Gas Meter: Basement 1 Main Gas Valve: Located at gas meter

5 Page 5 of 24 Roof Main Roof Surface Method of Inspection: On roof Unable to Inspect: 0% Material: Fiberglass shingle Moss growth noted Type: Gable Approximate Age: 7 years Porch Roof Surface Method of Inspection: Ladder at eaves Unable to Inspect: 0% Material: Fiberglass shingle Type: Gable Approximate Age: 7 years Flashing: Metal 1 Valleys: Metal 1 Skylights: 1 Plumbing Vents: Cast Iron 1 Electrical Mast: Mast with tie back at roof 1 Gutters: Aluminum Loose due to missing spikes 1 Downspouts: Aluminum 1 Leader/Extension: Underground Conductor Drains North Chimney 1 Chimney: Brick 20. Flue/Flue Cap: Clay Tile 2 Chimney Flashing: Metal

6 Page 6 of 24 Garage/Carport Attached Garage Type of Structure: Attached Car Spaces: 1 Garage Doors: Insulated aluminum Door Operation: Mechanized Door Opener: Overhead Door No safety reverse system in operation Service Doors: Fire rated Add closing mechanism to entry door Ceiling: Plaster Board Walls: Concrete Cracks present Floor/Foundation: Poured concrete Crack present at right foundation wall with some shifting Hose Bibs: Electrical: 110 VAC Smoke Detector: 1 Heating: 1 Windows: Block Electrical Service Size Amps: 100 Volts: 120/240 VAC Service: Copper 120 VAC Branch Circuits: Copper 240 VAC Branch Circuits: Copper and aluminum Conductor Type: Romex, Non-metallic sheathed cable Ground: Plumbing ground only Smoke Detectors: Battery operated Garage Electric Panel Manufacturer: Cutler-Hammer Maximum Capacity: 100 Amps Main Breaker Size: 100 Amps Breakers: Copper 1 AFCI:

7 Page 7 of 24 Electrical (Continued) 1 GFCI: 1 Is the panel bonded? Yes No Structure Structure Type: Wood frame Foundation: Poured concrete Common cracks noted near windows, Spalled foundation corners noted Differential Movement: Differential settlement present Cracks will require monitoring Beams: Steel I-Beam Joists/Trusses: 2x10 Piers/Posts: Not visible Floor/Slab: Poured slab Stairs/Handrails: Wood stairs with wood handrails Handrails missing to lower level from kitchen(safety) Subfloor: Plywood Attic Partial house-upper Roof Attic Method of Inspection: In the attic Unable to Inspect: 20% Roof Framing: 2x6 Rafter Sheathing: Plywood Ventilation: Roof and soffit vents Insulation: Fiberglass Insulation Depth: 10"

8 Page 8 of 24 Attic (Continued) Attic Fan: Direct drive Install junction box with coverplate at open splice to attic fan House Fan: Belt drive with manual controls Wiring/Lighting: 110 VAC lighting circuit Moisture Penetration: No previous water penetration noted Partial house-lower Attic 1 Method of Inspection: In the attic Unable to Inspect: 0% Roof Framing: 2x6 Rafter Sheathing: Plywood Ventilation: Ridge and soffit vents, Gable vents Torn screens at gable vents, Remove birds nesting Insulation: Fiberglass Insulation Depth: 3" - 10" Recommend additional insulation be installed Wiring/Lighting: 110 VAC lighting circuit Moisture Penetration: Previous water penetration noted Previous water penetration noted at plumbing stack penetration with plastic in attic to catch water and towels wedged between house and rafter- no current leaking detected - Monitor Towels between house and rafters 2 Bathroom Fan Venting: Electric fan

9 Page 9 of 24 Basement Main Basement Unable to Inspect: 0% Ceiling: Suspended Acoustical System Walls: Drywall Evidence of past or present water leakage Floor: Carpet Floor Drain: Covered by Carpet Recommend uncovering Doors: Bi-fold, Louvered Windows: Glass Block Electrical: 110 VAC Exposed wiring present, Protect exposed wiring splices in junction box with cover plate above drop ceiling, Open ground exists at several 3 prong outlet receptacles Sump Pump: Moisture Evidence: Note Suspected mold present along perimeter finished walls at left and rear elevations. Further investigation behind finishes may uncover hidden problems not visible in this visual inspection. Mold conditions can cause acute and chronic health concerns and should be remediated. Corrections may include remediation protocols provided by an environmental hygienist for the suspected mold conditions and qualified remediation contractors to make required corrections. Basement Stairs/Railings: Wood stairs with no handrails Missing railing

10 Page 10 of 24 Air Conditioning Main AC System A/C System Operation: Appears serviceable 1 Condensate Removal: Plastic tubing Exterior Unit: Pad mounted Manufacturer: Carrier Area Served: Whole house Approximate Age: 15 Fuel Type: 220 VAC Temperature Differential: 12 degrees Type: Central A/C Capacity: 3 Ton Visible Coil: Copper core with aluminum fins Electrical Disconnect: Fused Exposed Ductwork: Metal Blower Fan/Filters: Direct drive with disposable filter Thermostats: Programmable Heating System Basement Heating System Heating System Operation: Note: Non-functional at time of inspection, A qualified HVAC technician is recommended to review and correct as required, Condensation leaking stains noted in cabinet Manufacturer: Carrier Type: Forced air Capacity: 80,000 BTUHR Area Served: Whole house Approximate Age: 15 Fuel Type: Natural gas

11 Page 11 of 24 Heating System (Continued) Heat Exchanger: 4 Burner Unable to Inspect: 60% Blower Fan/Filter: Belt drive with disposable filter Distribution: Metal duct Draft Control: Manual Flue Pipe: Single wall 1 Controls: Relief valve 1 Humidifier: Honeywell Not functioning 1 Thermostats: Programmable 1 Suspected Asbestos: No Plumbing Service Line: Copper Main Water Shutoff: Basement Water Lines: Copper Drain Pipes: Cast iron, Galvanized Slow draining noted at Tub. A licensed plumber is recommended to evaluate and estimate corrections, Galvanized drainpipe present- Galvanized piping corrodes from inside causing decreased flow rates and will eventually require updating. Noted new clean out cap which may indicate access was needed to clear drain clog Basement Water Service Caps: Accessible Vent Pipes: Cast iron Gas Service Lines: Cast iron Heater

12 Page 12 of 24 Plumbing (Continued) Water Heater Operation: Functional at time of inspection Manufacturer: A.O. Smith Type: Natural gas Capacity: 38 Gal. Approximate Age: 1 Area Served: Whole house 1 Flue Pipe: Single wall Install screws at exhaust vent piping fittings 1 TPRV and Drain Tube: Brass/Copper Bathroom Main Bathroom Closet: Single small Ceiling: Plaster Board Walls: Plaster Board Floor: Ceramic tile Doors: Hollow wood Windows: Electrical: 110 VAC GFCI Counter/Cabinet: Laminate Sink/Basin: One piece sink/counter top Cracks present in the sink bowl Faucets/Traps: Delta fixtures with a metal trap Tub/Surround: Porcelain tub and ceramic tile surround 1 Toilets: 3 Gallon Tank 1 HVAC Source: Air exchange ventilation 1 Ventilation: Electric ventilation fan Fan inoperative Master Half Bathroom 1 Closet: 1 Ceiling: Plaster Board

13 Page 13 of 24 Bathroom (Continued) Walls: Plaster Board Floor: Ceramic tile Doors: Hollow wood Windows: Vinyl Insulated Electrical: 110 VAC Counter/Cabinet: Laminate Sink/Basin: One piece sink/counter top Faucets/Traps: Delta fixtures with a PVC trap Leaking sink faucet at stem-repair 2 Toilets: 3 Gallon Tank The toilet is loose at the floor and will require re-securing, Leaking flush valve-repair 2 HVAC Source: Air exchange ventilation 2 Ventilation: Window Lower Level Half Bathroom 2 Closet: 2 Ceiling: Plaster Board 30. Walls: Plaster Board 3 Floor: Ceramic tile 3 Doors: Hollow wood 3 Windows: Steel casement 3 Electrical: 110 VAC 3 Counter/Cabinet: Laminate 3 Sink/Basin: Porcelain 3 Faucets/Traps: Delta fixtures with a PVC trap 3 Toilets: 3 Gallon Tank 3 HVAC Source: Forced air 40. Ventilation: Window

14 Page 14 of 24 Kitchen Main Level Kitchen Cooking Appliances: Whirlpool Ventilator: Broan Disposal: In-Sinkerator Dishwasher: Maytag Air Gap Present? Yes No Trash Compactor: Refrigerator: General Electric Microwave: General Electric Inoperative Sink: Stainless Steel Electrical: 110 VAC Plumbing/Fixtures: Stainless Steel Faulty vegetable sprayer-repair/replace 1 Counter Tops: Laminate 1 Cabinets: Laminate and composite materials 1 Ceiling: Plaster Board 1 Walls: Plaster Board 1 Floor: Ceramic tile 1 Windows: Vinyl Insulated 1 HVAC Source: Air exchange ventilation Bedroom Master Bedroom East Bedroom Closet: Single Ceiling: Plaster Board Walls: Plaster Board Floor: Hardwood Doors: Hollow wood Windows: Vinyl Insulated Electrical: 110 VAC HVAC Source: Forced air Smoke Detector: Closet: Single Ceiling: Plaster Board Walls: Plaster Board Floor: Hardwood Doors: Hollow wood Windows: Vinyl Insulated Electrical: 110 VAC

15 Page 15 of 24 Bedroom (Continued) 1 1 West Bedroom HVAC Source: Forced air Smoke Detector: Closet: Single Ceiling: Plaster Board Walls: Plaster Board Floor: Hardwood Doors: Hollow wood Windows: Vinyl Insulated Electrical: 110 VAC HVAC Source: Forced air Smoke Detector: Living Space Main Level Living Space Closet: Single Ceiling: Plaster Board Walls: Plaster Board Floor: Hardwood Floor shows evidence of previous water penetration/stains at front entry Doors: Hollow wood Windows: Vinyl Insulated Electrical: 110 VAC Reversed polarity determined at outlet receptaclerequires repair, Open ground exists at several 3prong outlet receptacles HVAC Source: Forced air Smoke Detector: Lower Level Living Space Closet: Small Closet door does not close

16 Page 16 of 24 Living Space (Continued) Ceiling: Plaster Board Cracks present Walls: Plaster Board Floor: Tile Doors: Hollow wood Windows: Vinyl Insulated Electrical: 110 VAC Faulty operation at light dimmer switch-repair, Open ground exists at several 3prong outlet receptacles 1 1 HVAC Source: Forced air Smoke Detector: Battery operated Laundry Room/Area Basement Laundry Room/Area Ceiling: Exposed framing Walls: Concrete Floor: Poured Doors: Bi-fold Windows: Glass block Electrical: 110 VAC/220 VAC Smoke Detector: Laundry Tub: PVC Laundry Tub Drain: PVC Washer Hose Bib: Washer and Dryer Electrical: 110 VAC/220 VAC 1 Dryer Vent: Flex foil 1 Washer Drain: Drains to laundry tub

17 Page 19 of 24 Marginal Summary This summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report. Lots and Grounds Walks: Concrete Cracks noted, Heaving at walk at rear 3 season storm door Cracks in Rear Walk Porch: Concrete Loose handrail Patio/Enclosure: Ceramic tile, Brick, Aluminum windows Loose limestone wall caps, Missing screens and some cranks, Lubricate as required Missing Cranks Exterior Hose Bibs: Gate Damaged handle needs replaced Garage/Carport Attached Garage Service Doors: Fire rated Add closing mechanism to entry door Attached Garage Walls: Concrete Cracks present Attached Garage Floor/Foundation: Poured concrete Crack present at right foundation wall with some shifting Structure Foundation: Poured concrete Common cracks noted near windows, Spalled foundation corners noted

18 Page 20 of 24 Structure (Continued) Foundation: (continued) Differential Movement: Differential settlement present Cracks will require monitoring Attic Partial house-upper Roof Attic Attic Fan: Direct drive Install junction box with coverplate at open splice to attic fan Partial house-lower Attic Insulation Depth: 3" - 10" Recommend additional insulation be installed 1 Partial house-lower Attic Moisture Penetration: Previous water penetration noted Previous water penetration noted at plumbing stack penetration with plastic in attic to catch water and towels wedged between house and rafter- no current leaking detected - Monitor Towels between house and rafters Basement 1 Main Basement Ceiling: Suspended Acoustical System 1 Main Basement Walls: Drywall Evidence of past or present water leakage 1 Main Basement Electrical: 110 VAC Exposed wiring present, Protect exposed wiring splices in junction box with cover plate above drop ceiling, Open ground exists at several 3 prong outlet receptacles Heating System 1 Basement Heating System Humidifier: Honeywell Not functioning Plumbing 1 Drain Pipes: Cast iron, Galvanized Slow draining noted at Tub. A licensed plumber is recommended to evaluate and estimate corrections, Galvanized drainpipe present- Galvanized piping corrodes from inside causing decreased flow rates and will eventually require updating. Noted new clean out cap which may indicate access was needed to clear drain clog

19 Page 21 of 24 Plumbing (Continued) Drain Pipes: (continued) 1 Basement Water Heater Flue Pipe: Single wall Install screws at exhaust vent piping fittings Bathroom 1 Main Bathroom Sink/Basin: One piece sink/counter top Cracks present in the sink bowl 20. Master Half Bathroom Faucets/Traps: Delta fixtures with a PVC trap Leaking sink faucet at stem-repair Living Space 2 Main Level Living Space Floor: Hardwood Floor shows evidence of previous water penetration/stains at front entry 2 Lower Level Living Space Closet: Small Closet door does not close 2 Lower Level Living Space Ceiling: Plaster Board Cracks present

20 Page 22 of 24 Marginal Summary (Continued)

21 Page 23 of 24 Defective Summary This summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report. Exterior Trim: Aluminum Missing piece at front Roof Gutters: Aluminum Loose due to missing spikes Garage/Carport Attached Garage Door Opener: Overhead Door No safety reverse system in operation Structure Stairs/Handrails: Wood stairs with wood handrails Handrails missing to lower level from kitchen(safety) Attic Partial house-lower Attic Ventilation: Ridge and soffit vents, Gable vents Torn screens at gable vents, Remove birds nesting Basement Main Basement Moisture Evidence: Note Suspected mold present along perimeter finished walls at left and rear elevations. Further investigation behind finishes may uncover hidden problems not visible in this visual inspection. Mold conditions can cause acute and chronic health concerns and should be remediated. Corrections may include remediation protocols provided by an environmental hygienist for the suspected mold conditions and qualified remediation contractors to make required corrections. Main Basement Basement Stairs/Railings: Wood stairs with no handrails Missing railing Heating System Basement Heating System Heating System Operation: Note: Non-functional at time of inspection, A qualified HVAC technician is recommended to review and correct as required, Condensation leaking stains noted in cabinet

22 Page 24 of 24 Defective Summary (Continued) Bathroom Main Bathroom Ventilation: Electric ventilation fan Fan inoperative Master Half Bathroom Toilets: 3 Gallon Tank The toilet is loose at the floor and will require re-securing, Leaking flush valve-repair Kitchen Main Level Kitchen Microwave: General Electric Inoperative 1 Main Level Kitchen Plumbing/Fixtures: Stainless Steel Faulty vegetable sprayer-repair/replace Living Space 1 Main Level Living Space Electrical: 110 VAC Reversed polarity determined at outlet receptacle- requires repair, Open ground exists at several 3prong outlet receptacles 1 Lower Level Living Space Electrical: 110 VAC Faulty operation at light dimmer switch-repair, Open ground exists at several 3prong outlet receptacles