SUNCE Marinkovic d.o.o. Lepenicki bulevar br Kragujevac Serbia. Hollow chamber profile - plastic Profile combination: Casement-frame

Size: px
Start display at page:

Download "SUNCE Marinkovic d.o.o. Lepenicki bulevar br Kragujevac Serbia. Hollow chamber profile - plastic Profile combination: Casement-frame"

Transcription

1 Evidence of Performance Test Report No PR02 (PB 01-K20-06-en-01) Client Product SUNCE Marinkovic d.o.o. Lepenicki bulevar br Kragujevac Serbia Hollow chamber profile - plastic Profile combination: Casement-frame Designation SYNEGO MD Basis *) EN ISO : SG 06-verpflichtend NB-CPD/SG06/11/ *) Correspond/s to the national standard/s (e.g. DIN EN) Representation 44 Performance-relevant product details Material Polyvinylchlorid (PVC-U) rigid; Face width B in mm 127; Reinforcement; Material Steel; Surface treatment metallic surface (incl. galvanized); Casement; Profile section, width in mm 79; thickness in mm 80; Frame; Profile section, width in mm 82; thickness in mm 80; Replacement panel; Edge cover in mm 19; Thickness in mm 44 Special features Sealing in glazing rebate Ve-PB en ( ) Results according to EN ISO : U f = 1.1 W/(m²K) Instructions for use The results obtained can be used as evidence in accordance with the above basis. Validity The data and results given relate solely to the tested and described specimen. This test does not allow any statement to be made on further characteristics of the present structure regarding performance and quality. ift Rosenheim Notes on publication The ift-guidance Sheet "Conditions and Guidance for the Use of ift Test Documents" applies. The cover sheet can be used as abstract. Contents The report contains a total of 6 page/s and annex (1 page). Konrad Huber, Dipl.-Ing. (FH) Head of Testing Department Building Physics Till Stübben, Dipl.-Ing. (FH) Operating Testing Officer Building Physics

2 Evidence of Performance Page 2 of 6 1 Object 1.1 Description of test specimen Hollow chamber profile - plastic Profile combination: Casement-frame Client Manufacturer System designation Material Face width B in mm 127 Sealing system Reinforcement Material Surface treatment Casement Profile section, width in mm 79 Profile section, thickness in mm 80 Reinforcement Width in mm 28 Height in mm 35 SUNCE Marinkovic d.o.o. REHAU AG + Co SYNEGO MD Polyvinylchlorid (PVC-U) rigid 1 x external, 1 x centre, 1 x internal Steel Thickness in mm 1.5 Special features Frame Profile section, width in mm 82 Profile section, thickness in mm 80 Reinforcement Width in mm 38 Height in mm 23 Thickness in mm 1.5 Replacement panel Length in mm 190 Edge cover in mm 19 Thickness in mm 44 metallic surface (incl. galvanized) Sealing in glazing rebate The description is based on specifications provided by the client and on inspection of the test specimen at the ift. (Item designations/ numbers as well as material specifications were provided by the client, unless designated as ift-tested.) Test specimen are described in the annex "Product/Sample description".

3 Evidence of Performance Page 3 of Sampling The following data for sampling have been presented to ift: Sampler: Date: Documentation: ift Rosenheim did not receive a sampling report. ift-test specimen-no.: PK02

4 Evidence of Performance Page 4 of 6 2 Procedure 2.1 Basic documents *) of the processes EN ISO : Thermal performance of windows, doors and shutters - - Part 2 - Numerical method for frames SG 06-verpflichtend NB-CPD/SG06/11/ EN :2006 Treatment of unventilated rectangular cavities when calculating thermal properties to EN ISO *) correspond/s to the national standard/s, e.g. DIN EN 2.2 Short description of process Uf The profile section is subdivided into a sufficient number of elements, with subdivision into smaller elements not having any effect on the total heat flow. The relevant materials / boundary conditions are determined and the total heat flow calculated. The heat flow is used to determine the thermal transmittance.

5 Evidence of Performance Page 5 of 6 3 Detailed results

6 Evidence of Performance Page 6 of 6

7 Attachment 1: Product illustration Page 1 of 1 Evidence of Performance Fig 1: Cross section test specimen PK01 Ve-PB en ( ) Fig 2: Simulation model test specimen PK01