SUBMITTAL PACKAGE CUSTOM HOLLOW METAL DOORS, FRAMES AND WINDOWS

Size: px
Start display at page:

Download "SUBMITTAL PACKAGE CUSTOM HOLLOW METAL DOORS, FRAMES AND WINDOWS"

Transcription

1 Box 1101, 140 Coal St. Raton, NM Phone Fax: SUBMITTAL PACKAGE CUSTOM HOLLOW METAL DOORS, FRAMES AND WINDOWS DATE: PROJECT: LOCATION: CONTRACTOR: QUANITITY: DOORS: FRAMES: MISC: FINISH: PRIMED ENGINEERED BY: REMARKS RMMI JOB# p. 1

2 ACTUAL WIDTH ACTUAL HEIGHT UNDERCUT UL LABEL SIZE & TYPE THICKNESS SWINGS RMM. NO ELEVATION SECTION TYPE SCTION WIDTH FRM. GUAGE OUT -TO-OUT DIMENSIONS WIDTH OUT -TO-OUT DIMENSIONS HEIGHT UL TAG HDW GROUP QUANTITY TYPE HARDWARE SET PAIRS H. SET-UP SIZE LOCK OR PANIC STRIKE BOLTS CLOSERS HOLDERS ROCKY MOUNTAIN METALS, INC SCHEDULE SHEET LINE # REMARKS DOORS FRAMES WALL ANCH BUTTS HARDWARE JOB PAGE REVISED

3 Rocky Mountain Metals, Inc. Manufacturing Notes and Conditions 1. Customer must supply hardware locations and door undercuts. Unless noted otherwise, doors will be fabricated with a ¾ undercut. 2. Customer must supply dimensions for all light cut outs and glass thickness. 3. Customer must supply all section widths, overall frame dimensions, and anchor type. 4. Customer must supply drawings for sidelights, transom and window frames. The drawings are to include all dimensions used and glass side with glass thickness. 5. Customer must furnish and unmarked copy of the approved hardware schedule and a complete list of standard templates required for the project. Non-standard templates and samples of existing hardware must be furnished upon request from RMMI. 6. RMMI will not start fabrication until all approved information is received. 7. RMMI will mortise, reinforce, drill and trap frames and doors for all mortise type hardware. All holes ½ or less in diameter are to be field drilled by others. 8. Frames will be reinforced only for application of surface applied hardware such as door checks, transom operators, brackets, etc. Doors will be reinforced only for application of surface applied hardware such as door pulls, push plates, door checks, escutcheons, kickplates, etc. All drilling and tapping for surface hardware to be done in the field by others. 9. Back charges will not be accepted unless inspected and approved by a RMMI representative. 10. RMMI shop drawings have been prepared for our use only and are subject to revisions. Errors incurred by other trades through the use of these details will not be RMMI responsibility. 11. Items not furnished by RMMI: glass, glazing, hardware, installation, erection, access doors and frames, weather-stripping silencers, insulation (other than used in door construction) thresholds, caulking, finish coats of paint, anchor bolts and astragals (other than flat bar type). 12. RMMI will not be responsible for fit of doors if jambs are not set true to plumb, nor for rust caused by gypsum plaster grouting, grout with anti-freeze additive or muriatic acid brick wash. RMMI WILL NOT BE RESPONSIBLE FOR IMPERFECTIONS SHOWN DUE TO THE USE OF HIGH GLOSS PAINT. RMMI Manufacturing Notes and Conditions 1/16/17

4 Door Construction: Door Product Specifications Doors shall be made of commercial galvanneald A40 sheet steel meeting ASTM-A GA, 14GA and 16GA available. Doors to have no visible seam on either face if under 10 0 in height or 4 0 in width. All doors shall have both edges fully welded and ground smooth. All doors to be thoroughly cleaned and will receive one coat of gray rust inhibiting primer paint Series polystyrene doors shall be 1 ¾ thick of composite construction. The interior of the door shall be filled with a rigid sheet of one pound density polystyrene which is securely bonded to both face sheets. The vertical edges shall be reinforced by a 16 gauge channel spot-welded to the face sheets. All lock and hinge reinforcements shall be drilled and tapped by the manufacturer. All doors are handed Series vertically stiffened doors shall be 1 ¾ thick of hollow metal construction and shall have continuous 20 gauge vertical stiffeners spaced not to exceed six inches apart. All spaces between stiffeners shall be insulated w/ fiberglass ¾ density insulation. The vertical edges shall be reinforced by a 16 gauge minimum continuous steel channel extending full height of the door. The top and bottom of the door shall be reinforced by 16 gauge minimum channel spot welded to the face sheets. All lock and hinge reinforcements shall be drilled and tapped by the manufacturer. All doors are handed Series temperature rise doors shall be 1 ¾ thick of composite construction. A one piece mineral board core shall be securely bonded to both face sheets. The vertical edges shall be reinforced by a 16 gauge channel spot-welded to the face sheets. All lock and hinge reinforcements shall be drilled and tapped by the manufacturer. All doors are handed. Door Product Specifications p.1

5 Door Product Specifications 1400 Series Fema 361 vertically stiffened doors shall be 1 ¾ thick 14 gauge of hollow metal construction and shall have continuous 18 gauge vertical stiffeners spaced not to exceed six inches apart. All spaces between stiffeners shall be insulated w/ fiber glass ¾ density insulation. The vertical edges shall be reinforced by a 12 gauge minimum continuous steel angle extending full height of the door. The top and bottom of the door shall be reinforced by 12 gauge minimum channel spot welded to the face sheets. All lock and hinge reinforcements shall be drilled and tapped by the manufacturer. All doors are handed. Note all doors must be provided with Securitech hardware for our Fema 361 label to be applied Series vertically stiffened lead lined doors shall be 1 ¾ thick of hollow metal construction and shall have continuous 20 gauge vertical stiffeners spaced not to exceed six inches apart. All spaces between stiffeners shall be insulated w/ fiberglass ¾ density insulation. A lead lined sheet of 1/32, 1/16 or 1/8 shall be applied between steel ribs and the door skin. The vertical edges shall be reinforced by a 16 gauge minimum continuous steel channel extending full height of the door. The top and bottom of the door shall be reinforced by 16 gauge minimum channel spot welded to the face sheets. All lock and hinge reinforcements shall be drilled and tapped by the manufacturer. All doors are handed. Door Product Specifications p.2

6 Hollow Metal Doors A full line of Hollow Metal Doors 1100 Doors with Polystyrene Core 1200 Steel Stiffened Doors 1300 Temperature Rise Doors 1400 Doors for Tornado Solutions 1500 Lead lined Doors Standard Door Details Face sheets to be formed from 12, 14, 16 or 18 Gauge Galvannealed A40 steel. A60 available. 7 Gauge 1 1/4 x 10 joggled hinge reinforcing. Drilled and tapped per template. 12 Gauge mortised hardware mounting tabs. 14 Gauge surface hardware and trim reinforcement, prepared for mortised units by hardware templates. 16, 18, 20 or 22 gauge door ribs, per arch, specifications, vertically spaced at 6 on center spot welded at 4 on center (standard is 22 gauge) reinforce perimeter of all cutouts with channel. 16 Gauge door top and bottom channels welded in place. Vertical door edges are to be welded full length and finished smooth and seamless. All door glazing stops to be set for 1/4 glass (3/8 space) unless otherwise requested by contractor. (NOTE) Glass should be cut 3/8 less than door cutout (exposed glass opening is 1 1/2 less than cutout dimensions,) Louver size is actual size of door cutout. Astrangals will be furnished on all exterior pairs of doors where assigned hardware permits. U.L. Rated pairs of doors must have astrangals if removable mullions or 2 vertical rod exit devices are not assigned. 1/8 between pairs of doors, head 1/8, jamb 1/8 bottom undercut 3/4 unless otherwise noted. HSV Door details, designs, manufacturing tolerances and hardware preparation p.1.

7 Hollow Metal Doors Manufacturing Tolerances Manufacturing tolerances shall be maintained within the following limits for Doors Width +/- 1/32 in. (.08mm) Height +/- 3/64 in. (1.2mm) Thickness +/- 1/16 in. (1.6mm) Hardware cutout dimensions/template dimensions , - 0 Hardware location +/- 1/32 in. (.08mm) Door details, designs, manufacturing tolerances and hardware preparation p.2.

8 Door Details - Typical Hardware Preparations Door details, designs, manufacturing tolerances and hardware preparation p.3.

9 Hollow Metal Frames A full line of standard and custom frames: Standard door frames, fully or face welded Window frames Sidelights Standard, window and sidelight frames can be supplied lead lined Knock down (KD) frames for welding Dry wall knock down (KD frames) Custom frames Standard Frame Details All miters are die cut to permit close tolerances. Inside perimeter of stop and face trim joints are welded, exposed welds are finished smooth. 12 Gauge surface closure reinforcing. Mortising and reinforcing as required by assigned closure template. 12 Gauge strike reinforcing, drilling and tapping to template. 7 Guage 1 1/4 x 10 joggled hinge reinforcing. Drilled and tapped per template. 16 Gauge wall anchors are designed to suit wall conditions. Counter sinks with angle spacer behind frame provided for anchorage (all bolts by others) 14 Gauge floor anchors. Type K unless noted otherwise) Frames are mortised reinforced. Cut out and beveled to insure proper operation with assigned hardware. All frames 1 piece welded construction unless noted otherwise. All frames punched for silencers: 3@ singles, 2@ doubles (silencers by others) Removable glazing stops to be 11/16 typical. 1/16 caulking space each side of glass shall be allowed unless otherwise requested by the contractor. Standard stops are 11/16 Manufacturing Tolerances for Frames Frames for single door or pair of doors: Width, measured between rabbets at the head; nominal opening width +1/18 1/32 Height (total length of jamb rabbet): nominal opening height +/- 3/64 Frames overlapping walls to have throat dimension 1/8 greater than dimensioned wall thickness to accommodate irregularities in wall construction. RMMI General Frame Info, standard frame elevations/sections & anchors p. 1

10

11

12 Hollow Metal Frames Standard frame elevations Standard frame sections Standard Drywall Mullion Cased Single rabbet Double egress RMMI General Frame Info, standard frame elevations/sections & anchors p. 2

13 Hollow Metal Frames Standard Frame Anchors RMMI General Frame Info, standard frame elevations/sections & anchors p. 3

1701 Hollow Metal Door with Polystyrene Core Bullet Resistant UL 752 Level 1

1701 Hollow Metal Door with Polystyrene Core Bullet Resistant UL 752 Level 1 1701 Hollow Metal Door with Polystyrene Core Bullet Resistant UL 752 Level 1 Face thickness 12 Ga. (.0994 min thickness) CS type B Construction Rigid polystyrene core bonded to both face sheets Hardware

More information

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100 COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100 Part 1 General 1.01 Work Included A. The work under this section shall include the furnishing of all items shown on the drawings and as specified,

More information

HOTEL SPECIFICATION SECTION 08100

HOTEL SPECIFICATION SECTION 08100 Part 1 General HOTEL SPECIFICATION SECTION 08100 1.01 Work Included A. The work under this section shall include the furnishing of all items shown on the drawings and as specified including, but not limited

More information

DETAILED METAL DOOR SPECIFICATION. UNIVERSITY CONTACT: Mark Golden, Supervisor of Structural Services (302)

DETAILED METAL DOOR SPECIFICATION. UNIVERSITY CONTACT: Mark Golden, Supervisor of Structural Services (302) DETAILED METAL DOOR SPECIFICATION UNIVERSITY CONTACT: Mark Golden, Supervisor of Structural Services (302) 831-8456 PART 1 GENERAL DOORS 1.01 GENERAL PROVISIONS I. The Drawings and General Provisions of

More information

HOLLOW METAL DOORS AND FRAMES SECTION HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL

HOLLOW METAL DOORS AND FRAMES SECTION HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL 13686.00 HOLLOW METAL DOORS AND FRAMES 081113-1 SECTION 081113 - HOLLOW METAL DOORS AND FRAMES 1.1 RELATED DOCUMENTS: PART 1 - GENERAL A. Drawings and general provisions of Contract, including General

More information

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 08110 - STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General, Supplementary, and Special Conditions and Division 1 Specification

More information

Product Description. Standard Sizes and Hardware Locations

Product Description. Standard Sizes and Hardware Locations F06 1 Product Description A-Series is Fleming s standard adjustable jamb depth 16 gage paintable galvanneal steel, knocked-down, drywall profile, punch mitered frame, used in drywall or existing masonry

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018 SECTION 08 1119 - STAINLESS STEEL DOOR AND FRAMES GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general specifications:

The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general specifications: Query No.1 ; we need more specs. about fire resistant doors Answer to Query No. 1: The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general

More information

INDEX. General Information Overview Full Flush Doors Stile and Rail Doors. Full Flush Door Constructions L Series

INDEX. General Information Overview Full Flush Doors Stile and Rail Doors. Full Flush Door Constructions L Series DOORS INDEX General Information............ 3.1 Overview Full Flush Doors Stile and Rail Doors Full Flush Door Constructions.....3.2 L Series.....................3.2.1 SL Series....................3.2.2

More information

SECTION METAL DOORS & FRAMES

SECTION METAL DOORS & FRAMES SECTION 08100 METAL DOORS & FRAMES PART 1 GENERAL 1.1 SCOPE Drawings and general provisions of the Contract, including General and Supplementary General Conditions and other Division 00 & 01 specification

More information

SECTION HOLLOW METALWORK. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION HOLLOW METALWORK. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. SECTION 081113 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting

More information

AMBICO Limited Section and ACOUSTIC STEEL DOOR AND FRAME ASSEMBLIES Page 1

AMBICO Limited Section and ACOUSTIC STEEL DOOR AND FRAME ASSEMBLIES Page 1 Page 1 This section includes AMBICO Acoustic Steel Doors and Frames as well as perimeter and bottom acoustic seals, and glazing if required all of which can be fire rated or non-rated. The aforementioned

More information

SECTION HOLLOW METAL DOORS AND FRAMES. A. Section includes steel doors and frames (hollow metal) indicated and as specified.

SECTION HOLLOW METAL DOORS AND FRAMES. A. Section includes steel doors and frames (hollow metal) indicated and as specified. SECTION 08 11 13 HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL 1.1 SUMMARY A. Section includes steel doors and frames (hollow metal) indicated and as specified. 1.2 SUBMITTALS A. Product Data: Submit

More information

INDEX General Information Flush Frames Drywall Frames Technical Data Sheets Anchors

INDEX General Information Flush Frames Drywall Frames Technical Data Sheets Anchors FLUSH FRAMES INDEX F and FN Series Frame Construction General Information.............2.1 F FN F FN F FN Flush Frames F Series Flush Frames...........2.2.1 Double Rabbet Single Rabbet Cased Open FN Series

More information

Hollow Metal Doors and Frames

Hollow Metal Doors and Frames University of New Hampshire University of New Hampshire Scholars' Repository Division 08 Openings Chapter 5 Technical Construction and Renovation Standards 1-25-2013 081113 - Hollow Metal Doors and Frames

More information

Division 08 Openings Section Ohio Utilities Protection Service New Office Building Bid Package B METAL DOORS AND FRAMES

Division 08 Openings Section Ohio Utilities Protection Service New Office Building Bid Package B METAL DOORS AND FRAMES SECTION 08 11 00 METAL DOORS AND FRAMES PART 1 GENERAL 1.1 SUMMARY A. Section includes: 1. Hollow Metal Doors. 2. Hollow Metal Frames. B. Related Sections: Documents relating to the work of this section

More information

SECTION HOLLOW METAL DOORS AND FRAMES

SECTION HOLLOW METAL DOORS AND FRAMES SECTION 081113 HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and General Provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

A. Minimum Thickness: Minimum thickness of base metal without coatings according to NAAMM-HMMA 803 or SDI A250.8.

A. Minimum Thickness: Minimum thickness of base metal without coatings according to NAAMM-HMMA 803 or SDI A250.8. SECTION 08 11 13 - HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

Lykes Steamship Building 1770 Tchoupitoulas St. New Orleans, LA

Lykes Steamship Building 1770 Tchoupitoulas St. New Orleans, LA SECTION 08110 - STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standard hollow metal doors and frames. 1.2 SUBMITTALS A. Product Data: For each type of product indicated. B.

More information

DIVISION 8 OPENINGS SECTION HOLLOW METAL DOORS AND FRAMES

DIVISION 8 OPENINGS SECTION HOLLOW METAL DOORS AND FRAMES DIVISION 8 OPENINGS SECTION 08 11 13 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Standard hollow metal doors frames. Minimum Thickness: Minimum thickness of base metal without coatings.

Standard hollow metal doors frames. Minimum Thickness: Minimum thickness of base metal without coatings. SECTION 081113 - PART 1 - GENERAL 1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this

More information

AMBICO Limited Section and DETENTION STEEL DOOR AND FRAME ASSEMBLIES Page 1

AMBICO Limited Section and DETENTION STEEL DOOR AND FRAME ASSEMBLIES Page 1 Page 1 This section includes AMBICO Detention Steel Door and Frame assemblies that can be fire rated or non-rated. This section relies on both the Canadian Steel Door Manufacturers Association (CSDMA.org)

More information

[PROJECT NAME] [PROJECT NUMBER] [CITY AND STATE]

[PROJECT NAME] [PROJECT NUMBER] [CITY AND STATE] SECTION 083953 - BLAST RESISTANT DOOR AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

Table of contents (click below or use bookmarks)

Table of contents (click below or use bookmarks) Frames Table of contents (click below or use bookmarks) General Information...23 Flush frames...25 F Series... 25 FN Series 1 flush face... 29 MU Series multi-use... 33 FE Series double egress...37 DE

More information

SECTION METAL DOORS & FRAMES

SECTION METAL DOORS & FRAMES SECTION 08-10-00 METAL DOORS & FRAMES Part 1 General 1.00 Scope of Work: Contractor shall provide labor and materials for a complete steel door install. 1.01 Section Includes A. Steel doors. B. Steel frames

More information

SECTION FIBERGLASS REINFORCED POLYESTER (FRP) DOORS AND ALUMINUM FRAMES

SECTION FIBERGLASS REINFORCED POLYESTER (FRP) DOORS AND ALUMINUM FRAMES SECTION 081613 FIBERGLASS REINFORCED POLYESTER (FRP) DOORS AND ALUMINUM FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN SECTION 08350 MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

B. Related Sections: The following Sections contain requirements that relate to this Section:

B. Related Sections: The following Sections contain requirements that relate to this Section: SECTION 08111 - STEEL DOOR FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Part 1 General 1. RELATED SECTIONS 1. Section 07 92 10 Joint Sealing 2. Section 08 71 00 Door Hardware 2. REFERENCES 1. American Society

More information

Revision Details TECH MANUAL

Revision Details TECH MANUAL Revision Details TECH MANUAL Technical Revisions for February 2016 Section Page Description Door 118 123 1 Revised drawing Removed page Revised glass size measurement Frames 121 Changed measurement for

More information

1. Bullet resistant hollow metal door and frame assemblies tested in accordance with UL 7 52 and in compliance with the following:

1. Bullet resistant hollow metal door and frame assemblies tested in accordance with UL 7 52 and in compliance with the following: Various Locations PROJECT#: R1401-01 SECTION 083400 -BULLET RESISTANT DOOR AND FRAMES PART 1-GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary

More information

SECTION STEEL DOORS AND FRAMES

SECTION STEEL DOORS AND FRAMES SECTION 08110 STEEL DOORS AND FRAMES PART 1 GENERAL 1.1 SECTION INCLUDES A. Flush Steel Doors. B. Temperature Rise Doors C. Steel Frames. 1.2 RELATED SECTIONS A. Section 08710 - Door Hardware. B. Section

More information

A NEW SCHOOL ATHENS BIBLE SCHOOL FOR THE PRESIDENT AND BOARD OF DIRECTORS ATHENS, ALABAMA

A NEW SCHOOL ATHENS BIBLE SCHOOL FOR THE PRESIDENT AND BOARD OF DIRECTORS ATHENS, ALABAMA McKee and Associates Architecture and Interior Design Addendum No. TWO Date: 09.27.17 Project: A NEW SCHOOL ATHENS BIBLE SCHOOL FOR THE PRESIDENT AND BOARD OF DIRECTORS ATHENS, ALABAMA A2.1 GENERAL PROJECT

More information

Spec. Standard: 07/25/ Revision: 01/31/14

Spec. Standard: 07/25/ Revision: 01/31/14 SECTION 08110 HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL 1.01 SCOPE: A. Summary of Work: The CONTRACTOR shall provide steel doors, frames, and related items, complete and operable, in accordance with

More information

B. Hollow Metal work for Interior frames, including Glazing Stops.

B. Hollow Metal work for Interior frames, including Glazing Stops. SECTION 081113 - HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

Rytec Corporation One Cedar Parkway Jackson, WI GO-RYTEC (262)

Rytec Corporation One Cedar Parkway Jackson, WI GO-RYTEC (262) Rytec Corporation One Cedar Parkway Jackson, WI 53037 1-888-GO-RYTEC (262) 677-9046 WWW.Rytecdoors.com Pharma-Swing Model Number PSW12002 SECTION 08300 HIGH PERFORMANCE FIBERGLASS SWING DOOR PAIR PART

More information

SECTION ALL GLASS ENTRANCES. 1. Lock cylinders for tempered glass entrance doors are specified in Division 8 section Finished Hardware.

SECTION ALL GLASS ENTRANCES. 1. Lock cylinders for tempered glass entrance doors are specified in Division 8 section Finished Hardware. 1 SECTION 08 4210 ALL GLASS ENTRANCES PART 1 - GENERAL 1.01 SUMMARY A. This section includes: 1. Vestibule doors matching entrance doors. 2. Sidelites. B. Related work in other sections: 1. Lock cylinders

More information

SECTION BLAST-RESISTANT DOORS AND FRAMES

SECTION BLAST-RESISTANT DOORS AND FRAMES Specification Sections noted are based on MasterSpec 2004/2010. It is intended as an "editable" proprietary specification, not necessarily following the individual paragraph numbering of any other source.

More information

C S I S E C T I O N STAINLESS STEEL DOORS AND FRAMES SPECIFICATIONS

C S I S E C T I O N STAINLESS STEEL DOORS AND FRAMES SPECIFICATIONS This section is based on products manufactured by Next Door Company, at the following address: 1840 North Commerce Parkway Suite 1 Weston, FL 33326-3200 tel. (954) 772-6666 or (888) 791 4450 fax (954)

More information

AMBICO Limited Section and RFI\EMI SHEILDED STEEL DOOR AND FRAME ASSEMBLIES Page 1

AMBICO Limited Section and RFI\EMI SHEILDED STEEL DOOR AND FRAME ASSEMBLIES Page 1 Page 1 This section includes AMBICO RFI/EMI Steel Shielding Steel Door and Frame assemblies. This section relies on both the Canadian Steel Door Manufacturers Association (CSDMA.org) industry standard,

More information

/ TECHNICAL DATA DOORS

/ TECHNICAL DATA DOORS / NICAL DOORS www.blackmountaindoor.com 310 Flint Drive Mt. Sterling, KY 40353 FAX: (859)762-0852 TOLL FREE: (855)370-4580 INDEX DOORS rev. 0 4-12-13 Description Door Elevations and Nomenclature Amweld

More information

ADVANCE METAL INDUSTRIES L.L.C.

ADVANCE METAL INDUSTRIES L.L.C. ADVANCE METAL INDUSTRIES L.L.C. Copyright reserved for ADVANCE METAL ''Due to continuos progress and product improvement, ADVANCE METAL reserves the right to make changes without notice'' DISCLAIMER OF

More information

St. Monica Food Pantry Hollow Metal Doors and Frames SBA-13105

St. Monica Food Pantry Hollow Metal Doors and Frames SBA-13105 St. Monica Food Pantry 08 1113-1 SECTION 08 1113 - HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL 1.1 SUBMITTALS: A. Shop drawings: Indicate door and frame elevations and sections, materials, gauges and

More information

SECTION STEEL DOORS AND FRAMES

SECTION STEEL DOORS AND FRAMES SECTION 08110 STEEL DOORS AND FRAMES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Metal doors and frames in accordance with the requirements of the Contract Documents, work includes but is not limited

More information

B. Related Requirements: 1. [Section "Door Hardware"] for door hardware for hollow metal doors.

B. Related Requirements: 1. [Section Door Hardware] for door hardware for hollow metal doors. SECTION 08 11 13 HOLLOW METAL DOORS AND FRAMES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

AMBICO Limited 7\2018 Section and OVERSIZED METAL DOORS AND FRAMES Page 1

AMBICO Limited 7\2018 Section and OVERSIZED METAL DOORS AND FRAMES Page 1 Page 1 This section includes Oversize Steel Doors and Frames and relies on the Canadian Steel Door Manufacturers Association (CSDMA.org) industry standard, as well as on the Hollow Metal Manufacturers

More information

ENGINEERING DETAILS for STANDARD SERIES EP & SERIES EH Embossed Six Panel 1-3/4" Doors

ENGINEERING DETAILS for STANDARD SERIES EP & SERIES EH Embossed Six Panel 1-3/4 Doors TEHNAL DATA S EP & EH SERES ENGNEERNG DETALS for STANDARD SERES EP & SERES EH Embossed Six Panel 1-3/4" Doors Specifications 1. Doors shall be formed of one 18 gage A40 or A60 Galv. steel sheet per ASTM

More information

SERIES H-HF-CH DOORS HONEYCOMB DOOR- (LOCKSEAM-SEAMLESS-SEAMWELDED)

SERIES H-HF-CH DOORS HONEYCOMB DOOR- (LOCKSEAM-SEAMLESS-SEAMWELDED) MADE RIGHT. HERE. SERIES H-HF-CH DOORS Specifications 1. H, HF and CH series doors shall be formed from two 14, 16 or 18 gage A60 Galv. steel sheets per ASTM A924 and A653 or CRS per ASTM A1008, A568 and

More information

SECTION SOUND CONTROL DOORS

SECTION SOUND CONTROL DOORS SECTION 08380 SOUND CONTROL DOORS 1.0 GENERAL 1.1 DESCRIPTION OF WORK A. Furnish and install Sound Control Doors specified herein and per the locations and orientations shown on the Contract Documents.

More information

ENGINEERING DETAILS for STANDARD TEMPERATURE RISE DOORS SERIES HR Full Flush 1¾" Doors SERIES CHR Seamless 1 ¾" Doors

ENGINEERING DETAILS for STANDARD TEMPERATURE RISE DOORS SERIES HR Full Flush 1¾ Doors SERIES CHR Seamless 1 ¾ Doors TEHNAL DATA S HR& HR SERES ENGNEERNG DETALS for STANDARD TEMPERATURE RSE S SERES HR Full Flush 1¾" Doors SERES HR Seamless 1 ¾" Doors Specifications 1. HR doors shall be formed from two 18 gage A60 Galvannealed

More information

1-3/4 Whisper Core Door Systems

1-3/4 Whisper Core Door Systems 1-3/4 TESTED AND IN COMPLIANCE WITH ASTM E90, ASTM E413, ASTM E1332, & ASTM E2235. DOOR SYSTEMS ARE IN COMPLIANCE WITH HMMA 865-03 & SDI-128 SPECIFICATIONS. COMPLETE WITH PERIMETER SOUND SEALS, BOTTOM

More information

SECTION ACCESS DOORS AND FRAMES

SECTION ACCESS DOORS AND FRAMES 11303, 26 th avenue Montreal, Quebec Canada H1E 6N6 Phone: (800) 479-1489 Fax: (800) 297-1489 PRODUCT GUIDE SPECIFICATION SECTION 08 31 00 S PART 1 - GENERAL 1.1 SUMMARY A. Provide access doors, frames

More information

SECTION DOOR HARDWARE. B. Related Sections: 1. Section STEEL DOORS AND FRAMES

SECTION DOOR HARDWARE. B. Related Sections: 1. Section STEEL DOORS AND FRAMES SECTION 08710 DOOR HARDWARE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of DIVISION 0 - BIDDING AND CONTRACT REQUIREMENTS and other DIVISION 1 Specification Sections, apply

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-08 34 63 (May 2011) --------------------------- Preparing Activity: NAVFAC Superseding UFGS-08 34 63 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are

More information

ELEVATION TYPES ELEVATION TYPES (SLIDING ENTRANCE) ELEVATION TYPES (BI-FOLDING ENTRANCE) SECTION DETAILS STAINLESS STEEL BRONZE ENTRANCES

ELEVATION TYPES ELEVATION TYPES (SLIDING ENTRANCE) ELEVATION TYPES (BI-FOLDING ENTRANCE) SECTION DETAILS STAINLESS STEEL BRONZE ENTRANCES COVER SHEET ELEVATION TYPES ELEVATION TYPES ELEVATION TYPES ELEVATION TYPES ELEVATION TYPES (SLIDING ENTRANCE) ELEVATION TYPES (BI-FOLDING ENTRANCE) SECTION DETAILS SECTION DETAILS SPECIFICATIONS: STILE

More information

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION

More information

AMBICO Limited Section and STAINLESS STEEL DOORS AND FRAMES Page 1

AMBICO Limited Section and STAINLESS STEEL DOORS AND FRAMES Page 1 Page 1 This section includes standard commercial Stainless Steel Doors and Frames. This section relies on both the Canadian Steel Door Manufacturers Association (CSDMA.org) industry standard, as well as

More information

Gauge. Hinge Reinforcements. Closer Reinforcement. Flush metal top cap. Thickness. Edge Seam. Steel Stiffeners. Details. Door Type

Gauge. Hinge Reinforcements. Closer Reinforcement. Flush metal top cap. Thickness. Edge Seam. Steel Stiffeners. Details. Door Type Steel Stiffeners 16 A60, 14 A60 1 3/4 standard; Custom thickness available 22 gauge; 4 wide; welded at each end and to faces of door Space between steel stiffeners filled with fiberglass insulation for

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 08 1113 - HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

PART 1 GENERAL HOLLOW METAL DOORS AND FRAMES

PART 1 GENERAL HOLLOW METAL DOORS AND FRAMES SECTION 08 11 13 (08110) PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Interior Hollow Metal Doors and Frames 2. Exterior Hollow Metal Doors and Frames 1.2 REFERENCES A. ASTM International (ASTM)

More information

AMBICO Limited Section BLAST RESISTANT STEEL DOOR & FRAME ASSEMBLY Page 1

AMBICO Limited Section BLAST RESISTANT STEEL DOOR & FRAME ASSEMBLY Page 1 Page 1 This section includes AMBICO blast resistant steel door & frame assemblies: fire rated and non-fire rated. This section relies on both Canadian Steel Door Manufacturers Association (CSDMA) as well

More information

SECTION ACCESS DOORS AND FRAMES

SECTION ACCESS DOORS AND FRAMES SECTION 08310 ACCESS DOORS AND FRAMES PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. [Fire rated] [and] [Non-fire rated] wall access panels. 2. [Fire rated] [and] [Non-fire rated] ceiling access

More information

AMBICO Limited Section and WOOD BULLET RESISTANT DOORS AND FRAMES Page 1

AMBICO Limited Section and WOOD BULLET RESISTANT DOORS AND FRAMES Page 1 Page 1 This section includes Bullet Resistant, Wood Doors and Bullet Resistant Steel Frames which meet the UL752 Standard for Bullet-Resisting Equipment. This section relies on both the Canadian Steel

More information

HMMA 867 GUIDE SPECIFICATIONS FOR LAMINATED CORE DOORS AND FRAMES HOLLOW METAL -16 MANUAL. SECOND EDITION April 1, 2016

HMMA 867 GUIDE SPECIFICATIONS FOR LAMINATED CORE DOORS AND FRAMES HOLLOW METAL -16 MANUAL. SECOND EDITION April 1, 2016 HOLLOW METAL MANUAL AMERICAN NATIONAL STANDARD ANSI/ NAAMM HMMA 867 0 8 11 13 Hollow Metal Doors and Frames -16 GUIDE SPECIFICATIONS FOR LAMINATED CORE HOLLOW METAL DOORS AND FRAMES SECOND EDITION April

More information

AMBICO Limited Section WOOD SOUND CONTROL DOOR AND STEEL FRAME ASSEMBLIES Page 1

AMBICO Limited Section WOOD SOUND CONTROL DOOR AND STEEL FRAME ASSEMBLIES Page 1 Page 1 This section includes AMBICO acoustic wood doors and steel frames, fire rated and non-rated. and relies on both Canadian Steel Door Manufacturers Association (CSDMA) and the Hollow Metal Manufacturers

More information

Specifications PRE ASSEMBLED DOOR SPECIFICATION PART 1 GENERAL 1.01 SUMMARY

Specifications PRE ASSEMBLED DOOR SPECIFICATION PART 1 GENERAL 1.01 SUMMARY PRE ASSEMBLED DOOR SPECIFICATION PART 1 GENERAL 1.01 SUMMARY A. This section pertains to items known commercially as a complete door opening assemblies. B. Complete door opening assemblies includes a door,

More information

SECTION BLAST RESISTANT DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION BLAST RESISTANT DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 083953 BLAST RESISTANT DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including Division 00 Bidding Requirements and other Division

More information

DIVISION 8 DOORS & WINDOWS

DIVISION 8 DOORS & WINDOWS Section Title 08000 GENERAL INFORMATION 08100 HOLLOW METAL DOORS AND FRAMES 08110 Steel Doors and Frames Door Frames Doors 08200 WOOD AND PLASTIC DOORS 08250 Door Opening Assemblies 08300 SPECIAL DOORS

More information

SECTION SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Insulated Steel Sectional Doors B. Track and Framing C. Hardware 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies:

More information

SECTION SERIES ALL GLASS ENTRANCES

SECTION SERIES ALL GLASS ENTRANCES 1 SECTION 08 4210 1200 SERIES ALL GLASS ENTRANCES PART 1 - GENERAL 1.01 SUMMARY A. This section includes: 1. Vestibule doors matching entrance doors. 2. Sidelites. B. Related work in other sections: 1.

More information

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL SECTION 08111 - STANDARD STEEL DOOR AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions apply to this Section.

More information

GUIDE SPECIFICATION Los Angeles World Airports SECTION HOLLOW METAL DOORS AND FRAMES

GUIDE SPECIFICATION Los Angeles World Airports SECTION HOLLOW METAL DOORS AND FRAMES SECTION 08 11 13 HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes hollow metal doors and frames. NOTE: The integration of the existing LAWA Security System into the new

More information

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS SECTION 08 4113 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Aluminum entrance doors and frames. 2. Glass infill panels. 3. Door hardware. B. Related Sections:

More information

HOLLOW METAL DOORS AND FRAMES

HOLLOW METAL DOORS AND FRAMES HOLLOW METAL DOORS AND FRAMES TECHNICAL INFORMATION INTERNATIONAL DOOR CLOSERS, INC. EAST 1920 AIR LANE DRIVE NASHVILLE, TN 37210 Phone: 800-225-6737 FAX: 615-885-0903 WWW.INTLDOORCLOSERS.COM WEST 4431

More information

.1 Blast-resistant non-fire rated pressed steel frames. .4 Factory supplied [and installed] glass and glazing.

.1 Blast-resistant non-fire rated pressed steel frames. .4 Factory supplied [and installed] glass and glazing. Page 1 This section includes AMBICO Blast Resistant Steel Window Frame assemblies. This section relies on both the Canadian Steel Door Manufacturers Association (CSDMA.org) industry standard, as well as

More information

SECTION / STC 52 METAL SOUND CONTROL DOORS

SECTION / STC 52 METAL SOUND CONTROL DOORS SECTION 08 34 73 / 08 34 73.13 STC 52 METAL SOUND CONTROL DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of the Contract, including general and Supplementary Conditions

More information

SECTION SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Doors B. Track and Framing 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.

More information

HMMA hmm08b Installation and Storage of Hollow Metal Doors and Frames. An American Institute of Architects (AIA) Continuing Education Program

HMMA hmm08b Installation and Storage of Hollow Metal Doors and Frames. An American Institute of Architects (AIA) Continuing Education Program Course Sponsor An American Institute of Architects (AIA) Continuing Education Program Credit for this course is 1 AIA HSW CE Hour National Assn. of Architectural Metal Mfrs. (NAAMM) 800 Roosevelt Rd.,

More information

SECTION ALUMINUM WINDOWS

SECTION ALUMINUM WINDOWS SECTION 08520 ALUMINUM WINDOWS PART 1 - GENERAL 1.01 SUMMARY A. Section includes: 1. Storefront systems and aluminum framed glass doors. 2. Hardware, fasteners, accessories, filler pieces, etc., required

More information

MegaSonic 2A - Series Flush Doors

MegaSonic 2A - Series Flush Doors FEATURES AND BENEFITS: MegaSonic Model 2A-B & 2A-F Series Doors offer the following standard unique features, which provides long term performance and durability: 1. Handicap Accessibility: MegaSonic assemblies

More information

1. Include plans, elevations, sections, details, and attachments to other work.

1. Include plans, elevations, sections, details, and attachments to other work. SECTION 102213- PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

Superior quality, a strong service commitment, and value are DKS watch words. Standard features built

Superior quality, a strong service commitment, and value are DKS watch words. Standard features built Introduction DKS Steel Door and Frame Systems, Inc. constantly strive to meet the demands of the steel door and frame industry by providing premium products to the customer. Superior quality, a strong

More information

TECHNICAL DATA SHEET NO. 102

TECHNICAL DATA SHEET NO. 102 OORS - SRIS THNIAL ATA SHT NO. 102 Series oors shall be as manufactured or furnished by Products, McKenzie, Tennessee 38201. (Standard components are bold.) Thickness - 1-3/4 or 1-3/8 Actual oor Size -

More information

FRAMES. TELL MANUFACTURING, INC Page

FRAMES. TELL MANUFACTURING, INC Page FRAMES TELL MFG offers SPARTAN FRAMES in 16 gauge galvannealed steel. Frames are knock-down construction and are designed to be installed on standard and non-standard wall sizes over pre-finished or unfinished

More information

SECTION DETENTION SECURITY HOLLOW METAL SLIDING DOORS, FRAMES AND HARDWARE

SECTION DETENTION SECURITY HOLLOW METAL SLIDING DOORS, FRAMES AND HARDWARE SECTION 11190 DETENTION SECURITY HOLLOW PART 1 - GENERAL 1.01 SUMMARY This Section includes detention security hollow metal products as scheduled in the contract drawings and as specified herein. 1.02

More information

Aluminum-Framed Entrances and Storefronts

Aluminum-Framed Entrances and Storefronts University of New Hampshire University of New Hampshire Scholars' Repository Division 08 Openings Chapter 5 Technical Construction and Renovation Standards 1-25-2013 084113 - Aluminum-Framed Entrances

More information

Acousti-Seal Encore Paired Panel (10650) Operable Partitions

Acousti-Seal Encore Paired Panel (10650) Operable Partitions Acousti-Seal Encore Paired Panel 10 22 26 (10650) Operable Partitions Optimal choice for straight-line openings that do not require multiple locations or offset storage Panels are hinged together in groups

More information

SECTION DETAILS (MECHANICALLY ASSEMBLY)

SECTION DETAILS (MECHANICALLY ASSEMBLY) COVER SHEET ELEVATION SHEET SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY) SECTION DETAILS (DOOR ASSEMBLY)

More information

SECTION STEEL DOORS AND FRAMES. A. Section Includes: Steel doors and frames including necessary accessories.

SECTION STEEL DOORS AND FRAMES. A. Section Includes: Steel doors and frames including necessary accessories. SECTION 08110 STEEL DOORS AND FRAMES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Steel doors and frames including necessary accessories. B. Section Does Not Include: Use of aluminum doors. C. Related

More information

1. Include construction details, materials, individual components and profiles, and finishes.

1. Include construction details, materials, individual components and profiles, and finishes. SECTION 08 31 13 - ACCESS DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings,and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION STEEL DOORS AND FRAMES. A. Section Includes: Steel doors and frames including necessary accessories.

SECTION STEEL DOORS AND FRAMES. A. Section Includes: Steel doors and frames including necessary accessories. SECTION 08110 STEEL DOORS AND FRAMES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Steel doors and frames including necessary accessories. B. Section Does Not Include: Use of aluminum doors. C. Related

More information

4G DOORS FRAMES HARDWARE

4G DOORS FRAMES HARDWARE 4G DOORS FRAMES HARDWARE! 31147 Plymouth Rd. Livonia MI 48150 734-883-7468 sales@4gdoors.com www.4gdoors.com Index Introduction Nomenclature Commercial Door Constuction - 1200, 1800 and 2000 Series 1700/32-1700

More information

SECTION SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Doors B. Track and Framing 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.

More information

HMMA GUIDE SPECIFICATIONS FOR SOUND CONTROL HOLLOW METAL DOOR AND FRAME ASSEMBLIES HOLLOW METAL MANUAL AMERICAN NATIONAL STANDARD ANSI/ NAAMM

HMMA GUIDE SPECIFICATIONS FOR SOUND CONTROL HOLLOW METAL DOOR AND FRAME ASSEMBLIES HOLLOW METAL MANUAL AMERICAN NATIONAL STANDARD ANSI/ NAAMM HOLLOW METAL MANUAL AMERICAN NATIONAL STANDARD ANSI/ NAAMM HMMA-865-13 METAL DOORS & FRAMES February 27, 2013 8d GUIDE SPECIFICATIONS FOR SOUND CONTROL HOLLOW METAL DOOR AND FRAME ASSEMBLIES FOURTH EDITION

More information

AN ISO 9001 CERTIFIED COMPANY

AN ISO 9001 CERTIFIED COMPANY D O O R S E R I E S AN ISO 9001 CERTIFIED COMPANY THE NEW FACES OF OVERLY! For more than 50 years, Overly, an ISO 9001 Certified Company, has been an industry leader in the design, testing and manufacturer

More information

Built to Order. Stile. Frames. Section Contents. Profiles. Elevations. Double Egress Frames Pocket Frames

Built to Order. Stile. Frames. Section Contents. Profiles. Elevations.  Double Egress Frames Pocket Frames Frames Section Contents General Frame Construction Profiles F-1.0 Typical Jamb & Sill Profiles F-2.0-2.1 Frame Welding Elevations F-3.0 Frame Elevations F-4.0-4.2 Custom Frame Elevations Panel Types +

More information

AMBICO Limited Section and ACOUSTIC STEEL WINDOW FRAME ASSEMBLIES Page 1

AMBICO Limited Section and ACOUSTIC STEEL WINDOW FRAME ASSEMBLIES Page 1 Page 1 This section includes AMBICO Acoustic Steel Window Frames that are glazed as part of a complete assembly. Items are designed to be fixed-in place and shall be inoperable. These items are an integral

More information