1 3 4" ARRISCRAFT VENEER " NOMINAL AIR SPACE 2" RIGID INSULATION 8" CMU REINFORCED CONCRETE SLAB OVER METAL DECK - REFER TO STRUCTURAL DWGS 20 FIRST FLOOR 343' - 5" CONTINUOUS SEALANT TERMINATION BAR STAINLESS STEEL METAL COUNTER FLASHING TPO MEMBRANE ROOFING OVER BONDING ADHESIVE MEMBRANE FLASHING 5/8" DENSGLASS SHEATHING FIREPROOFING 8" RIGID INSULATION WITH STAGGERED AND TAPED JOINTS 5/8" DENSGLASS SHEATHING OVER -/2" METAL DECK CEILING AS SCHEDULED MASONRY TIES AT 24" OC VERTICALLY CONSTRUCTION DOCUMENTS - PHASE 2 RD-6

2 ' - 2 /4" 7 5/8" 2" 3 5/8" " MEMBRANE FLASHING OVER BONDING ADHESIVE PRE-FORMED METAL COPING WITH METAL CLEATS 2 LAYERS 3/4" PLYWOOD TPO MEMBRANE ROOFING OVER BONDING ADHESIVE COMPRESSIBLE FOAM EXPANSION TAPE 5/8" DENSGLASS SHEATHING " NOMINAL AIR SPACE 8" RIGID INSULATION WITH STAGGERED AND TAPED JOINTS 5/8" DENSGLASS SHEATHING -/2" METAL DECK CAVITY VENT 2" RIGID INSULATION 8" CMU 20 ATTIC FLOOR 363' - 4 /4" MASONRY TIES AT 24" OC VERTICALLY FIREPROOFING CEILING AS SCHEDULED 4" ARRISCRAFT VENEER 5/8" TYPE 'X' GYPSUM BOARD OVER 7/8" METAL FURRING CONSTRUCTION DOCUMENTS - PHASE 2 RD-7

3 CONTINUOUS SEALANT STAINLESS STEEL GRAVEL STOP W/ DRIP EDGE CORROGATED MASONRY TIES CONT. 2X P.T. WOOD BLOCKING TPO MEMBRANE ROOFING OVER ICE & WATER SHIELD MEMBRANE TAPERED RIGID INSULATION CRICKET -TAPER /2" /FT. TO ROOF DRAIN NEW BRICK TO MATCH EXISTING 3/4" CEMENTITIOUS ROOF SHEATHING (PHASE ) THRU WALL FLASHING 0" STRUCTURAL INSULATED PANEL (PHASE ) CONTINUOUS SEALANT STAINLESS STEEL METAL COUNTER FLASHING /2" METAL ROOF DECK (PHASE ) TERMINATION BAR WITH CONTINUOUS SEALANT CAVITY WEEP TPO MEMBRANE FLASHING CONT. 2X P.T. WOOD BLOCKING COMPRESSIBLE FOAM EXPANSION JOINT TPO MEMBRANE ROOFING OVER BONDING ADHESIVE ON 5/8" DENSGLASS SHEATHING EXTEND STUDS, INSULATION, VAPOR BARRIER, AND GYPSUM BOARD TO UNDERSIDE OF DECK 8" RIGID INSULATION OVER 5/8" DENSGLASS SHEATHING ON -/2" METAL DECK NEW METAL 6" OC. (PHASE ) REFER TO STRUCTURAL DRAWINGS VAPOR BARRIER 5/8" GYPSUM BOARD ON INTERIOR SIDE FIREPROOFING - REFER TO INSULATION AND INSULATION RETAINER CLIP EXISTING BRICK WALL CONSTRUCTION DOCUMENTS - PHASE 2 RD-8

4 RD-9 FIREPROOFING - REFER TO CEILING AS SCHEDULED EXISTING 20 MASONRY WALL TO REMAIN 8" RIGID INSULATION OVER 5/8" DENSGLASS SHEATHING ON - /2" METAL DECK COMPRESSIBLE INSULATION IN INSULATION RETAINER CLIP 5/8" DENSGLASS SHEATHING 8" MIN. COMPRESSIBLE FOAM EXPANSION JOINT TPO MEMBRANE ROOFING OVER BONDING ADHESIVE TERMINATION BAR WITH CONTINUOUS SEALANT STAINLESS STEEL METAL COUNTER FLASHING WITH CONTINUOUS SEALANT IN REGLET PAINTED STEELROOF LADDER WITH WELDED STEEL PAINTED LADDER RUNGS AND ANCHORED TO MASONRY WALL 7"

5 RD-25 CONTINUOUS BENT PLATE - REFER TO FIREPROOFING - REFER TO #5 BARS, TYP. REFER TO 4-/2" REINFORCED CONCRETE SLAB OVER -/2" METAL DECK. REFER TO GREEN ROOF 428' - 0" MM 625EV-FR HYDROFLEX 30 ROOTSTOP 8" CONTINUOUS RIGID INSULATION GARDENDRAIN GR50 2' - 0" SYSTEM FILTER 6" BALLAST ROOFING 0" CONCRETE CURB - REFER TO TERMINATION BAR CONTINUOUS SEALANT STAINLESS STEEL METAL FLASHING CORRUGATED METAL PANEL SIDING 3" KARRIER INSULATED METAL PANEL SYSTEM 3-5/8" METAL STUDS AT 6" OC TYP. WITH 3-/2" MINERAL WOOL INSULATION AIR / VAPOR BARRIER " TYPE X GYPSUM BOARD 5/8" FIRE RATED DENSGLASS SHEATHING 5

6 RD-28 FIREPROOFING - REFER TO #5 BARS, TYP. REFER TO CONTINUOUS BENT PLATE - REFER TO 4-/2" REINFORCED CONCRETE SLAB OVER -/2" METAL DECK - REFER TO STRUCTURAL DWGs MM 625EV-FR HYDROFLEX 30 GREEN ROOF 428' - 0" ROOT STOP 8" CONTINUOUS RIGID INSULATION 6" MINERAL WOOL BATT INSULATION ' - 4" -3/4" THICK INSULATED GLASS 4" TOP AND 4" BASE HANOVER ELEVATOR PEDESTAL, TYP. 8" PREFINISHED ALUMINUM WINDO SYSTEM HORIZONTAL MULLION 24" X 24" HANOVER PREST PAVER OVER HANOVER ELEVATOR PEDESTAL SYSTEM (2) LAYERS 3/4" PLYWOOD ADHERED TO CONCRETE CURB PRESSURE TREATED WOOD BLOCKING ADHERED TO CONCRETE CURB PRE-FORMED METAL COPING (BY CURTAINWALL MANUFACTURER) /2" LAMINATED GLASS IN ALUMINUM WINDOW SYSTEM - BOTTOM AND SIDES RAILING SYSTEM GALVANIZED SUPPORT FRAMING - REFER TO STRUCTURAL ON DRWG S5.5 /4" 0" 9 /4" ' - 8 /2"

7 RD-29 FIREPROOFING - REFER TO 4-/2" REINFORCED CONCRETE SLAB OVER -/2" METAL DECK. REFER TO MM 625EV-FR PRESSURE TREATED 2X2X8" LONG SELECT STRUCTURAL WOOD BLOCKING HYDROFLEX 30 ROOTSTOP 8" CONTINUOUS RIGID INSULATION STEEL BASE PLATES BOLTED THROUGH SLAB - REFER TO GARDENDRAIN GR50 6" BALLAST ROOFING SYSTEM FILTER ' - 0" 4"Ø GALVANIZED STEEL PIPE BOLTED THROUGH SLAB AND TO COLUMN - REFER TO STRUCTURAL DWGs

8 RD-30 FIREPROOFING - REFER TO 4-/2" REINFORCED CONCRETE SLAB OVER -/2" METAL DECK. REFER TO MM 625EV-FR HYDROFLEX 30 ROOTSTOP GREEN ROOF 428' - 0" MM 625EV-FR HYDROFLEX 30 ROOTSTOP 8" CONTINUOUS RIGID INSULATION 8" GARDENDRAIN GR50 PERFORATED GARDENEDGE METAL EDGE RESTRAINT UNDER GARDENDRAIN 6" BALLAST ROOFING SYSTEM FILTER 24" X 24" HANOVER PREST PAVER OVER HANOVER ELEVATOR PEDESTAL SYSTEM STEEL COLUMN, REFER TO 4" TOP AND 4" BASE HANOVER ELEVATOR PEDESTAL, TYP. MECHANICAL EQUIPMENT SCREEN 6.3

9 4"Ø GALVANIZED STEEL PIPE BOLTED THROUGH SLAB - REFER TO 6" BALLAST ROOFING SYSTEM FILTER GARDENDRAIN GR50 8" CONTINUOUS RIGID INSULATION ROOTSTOP HYDROFLEX 30 MM 625EV-FR STEEL BASE PLATES BOLTED THROUGH SLAB - REFER TO PRESSURE TREATED 2X2X8" LONG SELECT STRUCTURAL WOOD BLOCKING GREEN ROOF 428' - 0" 4-/2" REINFORCED CONCRETE SLAB OVER -/2" METAL DECK. REFER TO FIREPROOFING - REFER TO CONSTRUCTION DOCUMENTS - PHASE 2 RD-3

10 RD-32 MM 625EV-FR HYDROFLEX 30 ROOTSTOP FIREPROOFING - REFER TO 8" CONTINUOUS RIGID INSULATION 4-/2" REINFORCED CONCRETE SLAB OVER -/2" METAL DECK. REFER TO GREEN ROOF 428' - 0" 8" GARDENDRAIN GR50 24" X 24" HANOVER PREST PAVER OVER HANOVER ELEVATOR PEDESTAL SYSTEM 6" BALLAST ROOFING 4" TOP AND 4" BASE HANOVER ELEVATOR PEDESTAL, TYP. SYSTEM FILTER PERFORATED GARDENEDGE METAL EDGE RESTRAINT UNDER GARDENDRAIN H

11 RD-33 FIREPROOFING - REFER TO CONTINUOUS BENT PLATE - REFER TO #5 BARS, TYP. REFER TO PRECAST BEARING CONNECTION BY PRECAST MANUFACTURER 4-/2" REINFORCED CONCRETE SLAB OVER -/2" METAL DECK - REFER TO STRUCTURAL DWGs PRECAST CONCRETE PANEL MM 625EV-FR GREEN ROOF 428' - 0" HYDROFLEX 30 ROOT STOP 8" CONTINUOUS RIGID INSULATION (2) LAYERS 3/4" PLYWOOD ADHERED TO CONCRETE CURB AND PANEL 4" TOP AND 4" BASE HANOVER ELEVATOR PEDESTAL, TYP. MM 625EV-FR HYDROFLEX 30 24" X 24" HANOVER PREST PAVER OVER HANOVER ELEVATOR PEDESTAL SYSTEM PRESSURE TREATED WOOD BLOCKING BEYOND 6 /2" 7"x/2"x8" PLATE ANCHORED WITH (4) /2"Ø HIT-HY 50 EPOXY ANCHORS PRE-FORMED METAL COPING /2" TEMPERED GLASS IN ALUMINUM WINDOW SYSTEM - BOTTOM AND SIDES RAILING SYSTEM CONTINUOUS SEALANT AT PERIMETER GALVANIZED SUPPORT FRAMING. ALIGN WITH CURTAIN WALL MULLIONS - REFER TO STRUCTURAL ON DWG S5.5 5" 5" 2' - 0"

12 RD-34 FIREPROOFING - REFER TO CONTINUOUS BENT PLATE - REFER TO #5 BARS, TYP. REFER TO 4-/2" REINFORCED CONCRETE SLAB OVER -/2" METAL DECK - REFER TO STRUCTURAL DWGs PRECAST BEARING CONNECTION BY PRECAST MANUFACTURER PRECAST CONCRETE PANEL MM 625EV-FR GREEN ROOF 428' - 0" HYDROFLEX 30 ROOT STOP 8" CONTINUOUS RIGID INSULATION ' - 4" 4" TOP AND 4" BASE HANOVER ELEVATOR PEDESTAL, TYP. 24" X 24" HANOVER PREST PAVER OVER HANOVER ELEVATOR PEDESTAL SYSTEM PRESSURE TREATED WOOD BLOCKING ADHERED TO CONCRETE CURB (2) LAYERS 3/4" PLYWOOD ADHERED TO CONCRETE CURB AND PANEL PRE-FORMED METAL COPING (BY CURTAINWALL MANUFACTURER) /2" TEMPERED GLASS IN ALUMINUM WINDOW SYSTEM - BOTTOM AND SIDES RAILING SYSTEM GALVANIZED SUPPORT FRAMING - REFER TO STRUCTURAL ON DRWG S5.5 0" " ' - " 2' - 0"

13 RD-35 MM 625EV-FR HYDROFLEX 30 FIREPROOFING - REFER TO ROOTSTOP 8" CONTINUOUS RIGID INSULATION 4-/2" REINFORCED CONCRETE SLAB OVER -/2" METAL DECK. REFER TO GREEN ROOF 428' - 0" 8" GARDENDRAIN GR50 3/4" 24" X 24" HANOVER PREST PAVER OVER HANOVER ELEVATOR PEDESTAL SYSTEM LITETOP EXTENSIVE GROWING MEDIA - MAINTAIN 3/4" BELOW METAL EDGE PERIMETER 4" TOP AND 4" BASE HANOVER ELEVATOR PEDESTAL, TYP. PERFORATED GARDENEDGE METAL EDGE RESTRAINT UNDER GARDENDRAIN SYSTEM FILTER EXTENSIVE PLANT MATERIAL G

14 RD-37 FIREPROOFING - REFER TO MM 625EV-FR HYDROFLEX 30 4-/2" REINFORCED CONCRETE SLAB OVER - /2" METAL DECK. REFER TO ROOTSTOP GREEN ROOF 428' - 0" 8" CONTINUOUS RIGID INSULATION PRESSURE TREATED SELECT STRUCTURAL 2X2X8" WOOD BLOCKING STEEL BASE PLATES BOLTED THROUGH SLAB - REFER TO GARDENDRAIN GR50 GARDENDRAIN GR50 3/4" SYSTEM FILTER LITETOP EXTENSIVE GROWING MEDIA - MAINTAIN 3/4" BELOW METAL EDGE PERIMETER 6" BALLAST ROOF SYSTEM FILTER GALVANIZED STEEL COLUMN - REFER TO STRUCTURAL DWGs EXTENSIVE PLANT MATERIAL MECHANICAL EQUIPMENT SCREEN PERFORATED GARDENEDGE METAL EDGE RESTRAINT UNDER GARDENDRAIN

15 NOTES:.,000 LBS. WORKING LOAD IN ANY DIRECTION. 2. ASSEMBLY SHOWN IS STD. 5" AND 8" HIGH MODELS FOR WELDING TO MINIMUM 4" WIDE FLANGE. 3. STEEL PIER SIZE VARIES WITH ANCHOR HEIGHT (SEE ANCHOR CHART) 4. ASSEMBLY SHOWN WITH CONVENTIONAL SINGLE PLY ROOFING (BY OTHERS) - NO FLASHING. GALVANIZED STEEL PIER FIREPROOFING MAX. LIMIT = 42" CONSTRUCTION DOCUMENTS - PHASE 2 RD-38

16 RD-39,000 lbs. MAX. WORKING LOAD HOT DIP GALVANIZED HSS 4" O.D. " MAX. /4" TYP. FIREPROOFING STEEL PLATE HOT DIP GALVANIZED L = 44" MAX. /4" TYP. STEEL PLATE HOT DIP GALVANIZED STEEL 'C' CHANNEL HOT DIP GALVANIZED 8" MIN. ' 2" - 0" STEEL PLATE (EACH SIDE) HOT DIP GALVANIZED DETACHABLE WEATHERPROOF CAP WITH WING NUT LOCKING DEVICE TETHER STAINLESS STEEL BAR FOR SUSPENSION LINE

17 PAVER SYSTEM 0" XPS INSULATION STAINLESS STEEL ROUND BAR WATERPROOFING MEMBRANE -PROTECTION SHEET OVER 25 MILS HOT- APPLIED RUBBERIZED ASPHALT OVER REINFORCEMENT LAYER OVER 90 MILS HOT APPLIED RUBBERIZED APHALT GALVANIZED STEEL PIER SEE STRUCTURAL DRAWINGS FOR ROOF STRUCTURE ASSEMBLY STRUCTURAL STEEL W/ FIREPROOFING - SEE STRUCTURAL DRAWINGS 3" = '-0" CONSTRUCTION DOCUMENTS - PHASE 2 RD-40

18 RD-46 EXISTING STEEL BEAM EXISTING PRECAST CONC. PANEL EXISTING TPO MEMBRANE ROOFING TURN UP TPO MEMBRANE ROOFING ' - 0" LAP SEALANT TPO MEMBRANE FLASHING EXISTING PLYWOOD SHEATHING ' - 0" 3/4" NEW FULLY REINFORCED, FLUID APPLIED RESTORATION COATING SYSTEM. METAL COUNTERFLASHING, TO REMAIN CABLE REPLACE EXISTING SEALANT REUSE AND REINSTALL WALL MOUNTED CABLE HOLDER. NEW ELASTOMERIC COATING REGLET REMOVE AND REINSTALL BIRD BE GONE SYSTEM AFTER INSTALLATION OF ELASTOMERIC COATING REMOVE AND REINSTALL AIR TERMINAL AFTER INSTALLATION OF ELASTOMERIC COATING

19 RD-47 EXISTING STEEL BEAM EXISTING TPO MEMBRANE ROOFING TURN UP TPO MEMBRANE ROOFING ' - 0" 3/4" LAP SEALANT NEW FULLY REINFORCED, FLUID APPLIED RESTORATION COATING SYSTEM. EXISTING PLYWOOD SHEATHING METAL COUNTERFLASHING, TO REMAIN CABLE REPLACE EXISTING SEALANT 7" REUSE AND REINSTALL WALL MOUNTED CABLE HOLDER. AIR TERMINAL REGLET REMOVE AND REINSTALL BIRD BE GONE SYSTEM AFTER INSTALLATION OF ELASTOMERIC COATING REMOVE AND REINSTALL PARAPET WALL MOUNTED BRACKET ANCHORED TO PRECAST WALL PANEL REMOVE AND REINSTALL AIR TERMINAL AFTER INSTALLATION OF ELASTOMERIC COATING NEW ELASTOMERIC COATING

20 RD-48 EXISTING STEEL BEAM EXISTING GYPSUM ROOF BOARD PREFABRICATED METAL INSULATED ROOF CURB AND CAP FLASHING EXISTING TPO MEMBRANE FLASHING ' - 0 /2" VERIFY TREATED WOOD BLOCKING 3/4" x /4" WIDE GASKET FOR CURB FRAME AND ALL DUCT SUPPORT SURFACES FULLY REINFORCED FLUID APPLIED RESTORATION COATING SYSTEM GETS APPLIED UP TO AND BEYOND COUNTERFLASHING AS FAR AS POSSIBLE. METAL SLIP FRAMING MAY ALSO BE USED. COUNTERFLASHING

21 EXISTING ROOF DRAIN WITH CLAMPING RING EXISTING MEMBRANE ROOFING, COVER WITH NEW LAYER OF ALPHAGUARD BIO RESTORATION SYSTEM OVER TPO REMOVE STRAINER AND CLAMPING RING, GRIND SURFACES TO CLEAN BARE METAL, EXTEND RESTORATION COATING SYSTEM INTO DRAIN BOX. REINSTALL CLAMPING RING AND STRAINER. REPLACE PLASTIC STRAINERS (IF ANY) W/ CAST IRON EXISTING SPLICING CEMENT AND SEALANT NEW TAPERED INSULATION EXISTING GYPSUM ROOF BOARD EXISTING MEMBRANE ROOFING, COVER WITH NEW LAYER OF ALPHAGUARD BIO RESTORATION SYSTEM OVER TPO EXISTING RIGID INSULATION EXISTING GYPSUM SUBSTRATE BOARD EXISTING WOOD BLOCKING EXISTING METAL DECK CONSTRUCTION DOCUMENTS - PHASE 2 RD-49

22 RD-50 EXIST. PRECAST CONCRETE PANEL EXIST. REINF. CONC. FLOOR SLAB REPLACE AND RESEAL TERMINATION BAR WATERPROOF MEMBRANE NEW TAPERED INSULATION ' - 7/8" NEW PVC-TPA WATERPROOF MEMBRANE NEW HP MAT EXIST. CONC. CURB REMOVE AND REINSTALL PRECAST CONCRETE PAVER, REPLACE 5% WITH NEW PAVERS PRECOMPRESSED FOAM SEALANT BACKER ROD AND SEALANT EXIST. PIPE SLEEVES REPLACE SEALANT AROUND SLEEVES CLEAN OUT SEALANT JOINTS. PRIME SURFACES, INSTALL NEW BACKER ROD AND SEALANT EXISTING PREFINISHED METAL GUARD RAIL SYSTEM NEW ELASTOMERIC COATING

23 REMOVE AND REINSTALL PRECAST CONCRETE PAVER, REPLACE 5% WITH NEW PAVERS EXISTING COMPENSATOR PEDESTAL EXISTING INSULATION WATERPROOFING MEMBRANE -PROTECTION SHEET OVER 25 MILS HOT- APPLIED RUBBERIZED ASPHALT OVER REINFORCEMENT LAYER OVER 90 MILS HOT APPLIED RUBBERIZED APHALT EXISTING ROOF STRUCTURE ASSEMBLY 3" = '-0" CONSTRUCTION DOCUMENTS - PHASE 2 RD-5

24 PROVIDE TEMPORARY SUPPORT FOR DUCTWORK DURING INSTALLATION OF ALPHAGUARD BIO RESTORATION SYSTEM OVER EXISTING ADHERED TPO NEW ALPHAGUARD BIO RESTORATION SYSTEM REMOVE AND REINSTALL EXISTING ELEVATED DUCT SUPPORT LEG (GALV. PIPE) EXISTING TPO ROOF MEMBRANE NEW ROOF MEMBRANE PROTECTION PAD REMOVE AND REINSTALL EXISTING METAL SUPPORT LEG BASE EXISTING GYP. ROOF BOARD EXISTING ROOF INSULATION CONSTRUCTION DOCUMENTS - PHASE 2 RD-52

25 RD-53 NEW RIGID INSULATION MATCH EXISTING THICKNESS EXISTING ROOF DECK EXISTING BASE INSULATION EXISTING BASE INSULATION EXISTING METAL TRIM NEW ROOFING MEMBRANE 2' - 0" EXISTING INSULATED DUCT 5/8" EXTERIOR GRADE PLYWOOD ON 2 /2" METAL 6" O.C.

26 RD-55 INSTALL NEW RIGID ROOF INSULATION REMOVE, CLEAN AND REINSTALL ROOF DRAINS EXISTING ROOF STRUCTURE ASSEMBLY DECK DRAIN & OVERFLOW DRAIN COMBINATION REMOVE AND REINSTALL ELEVATOR PEDESTAL '-0" EXISTING WATERPROOFING MEMBRANE INSTALL NEW RIGID ROOF INSULATION REMOVE AND REPLACE EXISTING ROOF PAVER SYSTEM REMOVE AND REINSTALL COMPENSATOR PEDESTAL

27 EXISTING ROOF INSULATION TO REMAIN EXISTING TPO ROOF MEMBRANE REMOVE EXISTING ROOF TPO AND ROOF SUBSTRATE IN AREA OF DAMAGED ROOF INSULATION REMOVE DAMAGED PORTION OF EXISTING ROOF INSULATION DEMO OF DAMAGED ROOF INSULATION INSTALL NEW ALPHAGUARD BIO RESTORATION SYSTEM OVER ENTIRE ROOF EXISTING ROOF INSULATION TO REMAIN EXISTING TPO ROOF MEMBRANE INSTALL NEW RIGID ROOF INSULATION, TYPE AND THICKNESS TO MATCH EXISTING. COVER WITH LAYER OF NEW /2" EXT. GRADE GYP. BOARD SUBSTRATE AND COAT WITH LAYER OF NEW ROOF TPO TO MATCH EXISTING. REMOVE DAMAGED PORTION OF EXISTING ROOF INSULATION INSTALLATION OF NEW ROOF INSULATION CONSTRUCTION DOCUMENTS - PHASE 2 RD-57

28 RD-58 NEW 5/8" EXTERIOR GRADE GYP. SUBSTRATE BOARD TURN UP TPO MEMBRANE ROOFING ' - 0" NEW BUILT-UP ROOF INSULATION AT /2" PER FOOT, SLOPE TO ROOF DRAIN AS SHOWN ON ROOF PLAN SHEET A2.25-A4 TPO MEMBRANE FLASHING EXISTING PLYWOOD SHEATHING METAL COUNTERFLASHING, TO REMAIN 3/4" NEW FULLY REINFORCED, FLUID APPLIED RESTORATION COATING SYSTEM. LAP SEALANT CABLE REPLACE EXISTING SEALANT REUSE AND REINSTALL WALL MOUNTED CABLE HOLDER. NEW ELASTOMERIC COATING REGLET REMOVE AND REINSTALL BIRD BE GONE SYSTEM AFTER INSTALLATION OF ELASTOMERIC COATING REMOVE AND REINSTALL AIR TERMINAL AFTER INSTALLATION OF ELASTOMERIC COATING