1 PROJECT INFORMATION RENOVATION: THE SCOPE OF THE PROJECT CONSISTS OF REMOVAL OF EXISTING ROOF DRAINS, REMOVAL AND REUSE OF EXISTING PARAPET COPING, REMOVAL OF WET OR DAMAGED ROOF INSULATION AND LIMITED REMOVAL OF PARAPET FLASHING. PROVIDE NEW ROOF AND OVERFLOW DRAINS, COVER EXISTING 4 PLY BUILT UP ROOF (BUR) WITH SINGLE OR TWO PLY ROOF MEMBRANE AND REINSTALLING EXISTING PARAPET COPING. LOCATION: ZONING: C-1 OCCUPANCY CLASSIFICATION: TOTAL SCOPE OF WORK AREA: PARKING: OCCUPANCY: PROJECT DATA: 1231 LOUISVILLE ROAD FRANKFORT, KY BUSINESS - OFFICE. 7,263 S.F. AS EXISTING - NOT IN SCOPE 100 GSF / OCCUPANT CONSTRUCTION TYPE: 2-C UNDER 97 KY BUILDING CODE OCCUPANCY CLASSIFICATION: BUSINESS ALLOWABLE HEIGHT: 2 STORIES (TABLE 503) EXISTING HEIGHT: 2 STORY 27'-6" STORIES ABOVE GRADE ALLOWABLE AREA: AUTOMATIC SPRINKLER SYSTEM: PHYSICALLY ACCESSIBLE: OWNER: Kentucky Housing Corporation 1231 Louisville Road Frankfort. KY A.B. ANCHOR BOLT A/C AIR CONDITIONING ACOUST. ACOUSTICAL ADJ. ADJACENT A.F.F. ABOVE FINISH FLOOR A.H.U. AIR HANDLER UNIT ALT. ALTERNATE ALUM. ALUMINUM A.N. AS NOTED ANO. ANODIZE ANNUN. ANNUNCIATOR A.P. ACCESS PANEL APP. APPROXIMATE ARCH. ARCHITECT A.T. ACOUSTICAL TILE B.F.C. BROOM FINISH CONCRETE BD. BOARD BLDG. BUILDING BM. BEAM BOT. BOTTOM B.U.R. BUILT UP ROOF CP. CARPET CAB. CABINET CH. CHANNEL C.F. CONTRACTOR FURNISHED C.I. CONTRACTOR INSTALLED CEM. PLAS. CEMENT PLASTER C.B. CATCH BASIN C.G. CORNER GUARD C.I. CAST IRON C.J. CONTROL JOINT CL CENTER LINE C.C.T. CUBICLE CURTAIN TRACK CL, CLR. CLEAR CLG. CEILING CLO CLOSET C.M.U. CONCRETE MASONRY UNIT C.O. CASED OPENING COL. COLUMN COM. COMMON CONC. CONCRETE CONST. CONSTRUCTION CONT. CONTINUOUS CORR. CORRIDOR C.P. CONCRETE PLASTER C.A. CERAMIC TILE CTR. COUNTER, CENTER DEPT. DEPARTMENT DTL. D.F. DIA. DIAG. DIM. DISP. DN. DR. DWG.'S E.B. E.F. E.J. EL. ELEC. ELEV. E.P. EQUIP. EQ. E.S. E.T.R. EXG. EXP. EXT. E.W.C. F.A. F.D. F.E.C. F.F. F.H.C. FIN. FLR. FLUOR. F.R. FT FTG. FUR. GA. GALV. G.B. G.C. GL. GR. G.S. G.W.B. GYP. HGT. H.B. H.C. N/A NO YES CONTACTS ARCHITECT: ARCHITECTURAL INVESTMENTS 222 S. First St. - Ste. 206 Louisville, KY DETAIL DRINKING FOUNTAIN DIAMETER DIAGONAL DIMENSION DISPENSER DOWN DOOR DRAWINGS EXPANSION BOLT EXHAUST FAN EXPANSION JOINT ELEVATION ELECTRIC ELEVATOR ELECTRIC PANEL EQUIPMENT EQUIVALENT EXPOSED STRUCTURE EXISTING TO REMAIN EXISTING EXPANSION EXTERIOR ELECTRIC WATER COOLER FIRE ALARM FLOOR DRAIN FIRE EXTINGUISHER CABINET FINISH FLOOR FIRE HOSE CABINET FINISH FLOOR, FLOORING FLUORESCENT FIRE RATED FOOT FOOTING FURRING GAGE, GAUGE GALVANIZED GRAB BAR GENERAL CONTRACTOR GLASS GRADE GYPSUM SHEATHING GYPSUM WALLBOARD GYPSUM HEIGHT HOSE BIB HOLLOW CORE MEP ENGINEER: ABBREVIATIONS H.B. HARDBOARD H.M. HOLLOW METAL H.P. HIGH POINT HTG. HEATING HW., HDWE HARDWARE HR. HOUR H.S. HEAT STRENGTHENED H.V.A.C. HEATING VENTILATION AND AIR CONDITIONING I.D. INSIDE DIAMETER I.E. INVERT ELEVATION IN. INCH INSUL. INSULATION INT. INTERIOR INV. INVERT JAN. JANITOR JT. JOINT K.P. KICK PLATE K.S. KNEE SPACE KIT. KITCHEN KW KILOWATT L. LENGTH LAB. LABORATORY LAM. LAMINATE LAV. LAVATORY LBL. LABEL L.F. LINEAR FEET LKR. LOCKER L.L. LEAD LINED L.P. LOW POINT LT. LIGHT LT. WT. LIGHT WEIGHT MACH. MACHINERY MAS. MASONRY MAT'L,MTL. MATERIAL MAX. MAXIMUM M.B. MACHINE BOLT MECH. MECHANICAL MED. CAB. MEDICINE CABINET MED. PREP. MEDICAL PREPARATION MTL. METAL MFD., MFG. MANUFACTURED MIN. MINIMUM MIR. MIRROR MISC. MISCELLANEOUS MOLD. MOLDING M.O. MASONRY OPENING M.P. MOVABLE PARTITION LOCATION MAP PROJECT LOCATION SITE MAP M.R. MOISTURE RESISTANT M.S. METAL STUD M.H. MAN HOLE MULL. MULLION M.V. MIXING VALVE N.I.C. NOT IN CONTRACT NOM. NOMINAL N.T.S. NOT TO SCALE O.A. OVERALL O.F.C.I. OWNER FURNISHED CONTRACTOR INSTALLED O.C. ON CENTER O.D. OUTSIDE DIAMETER O.H. OPPOSITE HAND O.F.O.I. OWNER FURNISHED OWNER INSTALLED OPNG. OPENING OPP. OPPOSITE O.R. OPERATING ROOM PEMB, PEBM PRE-ENGINEERED METAL BUILDING (W/ OR W/ OUT MANUFACTURER) PT. PAINT PTN. PARTITION PASS. PASSAGE P.L. PROPERTY LINE PLAS. PLASTER PLMB. PLUMBING P. LAM. PLASTIC LAMINATE PLWD. PLYWOOD PORT. PORTABLE P.T. PRESSURE TREATED P.T.D. PAPER TOWEL DISPENSER P.V.C. POLY VINYL CHLORIDE Q.T. QUARRY TILE R.C.P. REINFORCED CONCRETE PIPE R. RADIUS, RISER R.C. RUNNER CHANNEL R.D. ROOF DRAIN REC. RECEPTACLE REF. REFRIGERATOR REIN. REINFORCING REQ'D. REQUIRED REV. REVERSE, REVISION RM. ROOM R.O. ROUGH OPENING R.L. ROOF LADDER S.A.B. SOUND ATTENUATION BLANKET SCHED. SCHEDULE S.C.W. SOLID CORE WOOD S.D. SOAP DISPENSER SEAL. SEALANT SEC. SECTION SH. SHELVING, SHELF, SHEET SIM. SIMILAR SP. SPACE S.P.B. SPECIMEN PASS BOX SPECS. SPECIFICATIONS STL. STEEL STO. STORAGE STR. STRUCTURAL SUS. SUSPENDED S.S. STAINLESS STEEL STA. STATION T.B. TOWEL BAR TELE. TELEPHONE TEMP. TEMPERED TLT. TOILET T.O.S. TOP OF STEEL T.P.D. TOILET PAPER DISP. T.P.H. TOILET PAPER HOLDER TYP. TYPICAL U.A. UNDER COUNTER U.N.O. UNLESS NOTED OTHERWISE UTIL. UTILITY VIN. VINYL VIN. BS. VINYL BASE VCT VINYL COMPOSITION TILE VERT. VERTICAL VEST. VESTIBULE V.I.F. VERIFY IN FIELD V.T.S. VINYL TRANSITION STRIP V.W.C. VINYL WALL COVERING W. WIDTH W/ WITH WC WATER CLOSET W/C WHEEL CHAIR WD. WOOD WP. WATERPROOFING W.W.F. WELDED WIRE FABRIC W.R.S. WELDED RESILIENT SHEET W.W.M. WELDED WIRE MESH YD. YARD SYMBOLS XXX NAME XX X-X XX A001 XXX A001 DR# W XX 99 TA-XX ELEVATION 0' - 0" FEC XXX A001 RENOVATION FOR: Kentucky Housing Corporation Office Building East Wing Roof Recover 1231 Louisville Road Frankfort, KY ROOM IDENTIFICATION (REFER TO FINISH SCHEDULE) BUILDING ELEVATION INTERIOR ELEVATION SECTION CUT DETAIL IDENTIFICATION DOOR IDENTIFICATION WINDOW IDENTIFICATION WALL TYPE KEYED NOTE TOILET ACCESSORY ELEVATION HEIGHT DATUM FIRE EXTINGUISHER IN RECESSED CABINET PREPARED BY: SHEETS GENERAL INFORMATION G-0 COVER SHEET ARCHITECTURAL A1.0 OVERALL SITE PLAN DEMOLITION ROOF PLAN A1.2 NEW WORK ROOF PLAN DEMOLITION ROOF DETAILS NEW WORK ROOF DETAILS COVER SHEET G-0

2 1 A 1.0 OVERALL SITE PLAN N.T.S. NORTH EXISTING MAIN ENTRANCE OVERALL SITE PLAN A1.0

3 1 B A ROOF PLAN - DEMOLITION CEILING - DEMOLITION ROOF DRAIN - DEMOLITION ATTENTION : A. CONTRACTOR SHALL BE RESPONSIBLE TO PERFORM WATER TESTS AT ALL ROOF DRAINS PRIOR TO ANY WORK, TO DETERMINE IF ANY OBSTRUCTION EXISTS IN ALL DRAIN LINES; CONTRACTOR SHALL PERFORM SAME WATER TEST AT COMPLETION OF NEW WORK. REFER TO B. PRIOR TO START OF WORK, NUMBER EACH EXISTING METAL COPING PANEL AND MARK ON PLANS (INCLUDED WITH SHOP DRAWINGS) C. HATCHED AREAS INDICATE AREAS WHERE NEW RIGID INSULATION IS TO BE INSTALLED. REFER TO INFRARED ROOF MOISTURE SURVEY ATTACHMENT IN SPECIFICATIONS. + HIGH POINT DEMOLITION ROOF PLAN

4 2 A1.2 ROOF PLAN - NEW WORK ATTENTION : A. CONTRACTOR SHALL BE RESPONSIBLE TO PERFORM WATER TESTS AT ALL ROOF DRAINS PRIOR TO ANY WORK, TO DETERMINE IF ANY OBSTRUCTION EXISTS IN ANY DRAIN LINE; CONTRACTOR SHALL PERFORM SAME WATER TEST AT COMPLETION OF NEW WORK. REFER TO B. PRIOR TO START OF WORK, NUMBER EACH EXISTING METAL COPING PANEL AND MARK ON PLANS (INCLUDED WITH SHOP DRAWINGS) C. HATCHED AREAS INDICATE AREAS WHERE NEW RIGID INSULATION IS TO BE INSTALLED. REFER TO INFRARED ROOF MOISTURE SURVEY ATTACHMENT IN SPECIFICATIONS. + HIGH POINT NEW WORK ROOF PLAN A1.2

5 A E PARAPET -DEMOLITION ROOF DRAIN -DEMOLITION B PARAPET OVERFLOW - DEMOLITION F C EXPANSION JOINT - DEMOLITION EQUIPMENT SUPPORT -DEMOLITION G D ROOF HATCH - DEMOLITION VENT THRU ROOF - DEMOLITION H MECH VENT CURB - DEMOLITION DEMOLITION ROOF DETAILS

6 J N PARAPET -DEMOLITION ROOF DRAIN -DEMOLITION K PARAPET OVERFLOW - DEMOLITION P L EXPANSION JOINT - DEMOLITION EQUIPMENT SUPPORT -DEMOLITION Q M ROOF HATCH - DEMOLITION VENT THRU ROOF - DEMOLITION R MECH VENT CURB - DEMOLITION S WALKWAY PAD T PEEL STOP NOTE: WALKWAY PADS MUST NOT BE INSTALLED OVER FIELD SEAMS AND FASTENER ROWS AND MUST BE GAPPED FROM THESE AREAS A MINIMUM OF 6". NEW WORK ROOF DETAILS