1 Client: Life Space Developments Ltd Date 30/01/2015 Targeted Refurbishment Survey Targeted Refurbishment Survey to: Sites C & D Boundary Way, Waford. WD25 7 Survey Date: 22 nd January 2015 Surveyor: Ashley Richardson Signed: a. R Richardson Report No. QSS11506 Final Report Date: 30 th January 2015 Tel: Newcastle Road, Cotes Heath Staffordshire. ST21 6RX Company Reg No Qube Environmental. Report No. QSS11506 Page 1 of 20

2 Client: Life Space Developments Ltd Date 30/01/2015 Targeted Refurbishment Survey Client: Site Address: Life Space Developments Ltd. Sites C & D Boundary Way Development Watford WD25 7 CONTENTS 1.0 Introduction Executive Summary Scope and Purpose Control of Asbestos Regulations Other Health & Safety Regulations Sources of Data Presentation of Findings Representative Sampling Report Format 2.0 Site Description Site History 3.0 Investigations Baseline Information Inspection, Sampling and Analysis Results of Laboratory Testing 4.0 Assessment and Overview Risk Assessment Methodology Data Sheets Overview 5.0 Conclusions & Recommendations Introduction Additional Inspection, Sampling and Testing 6.0 Caveats 7.0 References APPENDICES Appendix A Results of Laboratory Testing (UKAS Accredited Analysis Certificates) Data Sheets, layout drawing where applicable Qube Environmental. Report No. QSS11506 Page 2 of 20

3 Client: Life Space Developments Ltd Date 30/01/2015 Targeted Refurbishment Survey 1.0 Introduction Executive summary We have been advised by the clients representatives that the proposed works consist of demolition of garages located to this site and the building previously serving as the area Depot / lock up Yard. The remit of this survey was to the affected areas as discussed with the client and confirmed on site layout drawing provided by the client. No investigations of areas outside of these locations to this building were undertaken. Invasive investigations were of a restricted in that not all garages were internally accessible, it was also identified that personal items were still present within some of the accessible units. Materials POSITIVE for asbestos contamination have been identified during this investigation as follows (also see site layout and data sheets): Findings. Sample/ ref: QSS11506/ 14 & 16 Location: Site D. ALL Depot internal ceiling boards. Asbestos Insulation boards (AIB) Fully LICENSED MATERIAL, HIGH RISK PRODUCT. Works only by a LICENSED ASBESTOS REMOVAL CONTRACTOR under fully controlled conditions. 14 day notification to HSE required. Positive: Amosite & Chrysotile. (AIB). (Brown & White Asbestos) Sample/ ref: QSS11506/ 2,3,5,6,9,10,11 & 12 Location: Sites C & D. Majority of Garages, cement profile roof sheets. Cement sheet Products (AC), NON LICENSED MATERIALs Works only by a competent ASBESTOS REMOVAL CONTRACTOR. Positive Chrysotile. (AC). Qube Environmental. Report No. QSS11506 Page 3 of 20

4 Client: Life Space Developments Ltd Date 30/01/2015 Targeted Refurbishment Survey Sample/ ref: QSS11506/ 1 Location: Sites C. Garage 199 (quantity of cement product debris on sofa). Although the sample for the above item returned negative on analysis it is still possible that some contaminated materials may be present within the pile of debris. Therefore, for compliance purposes it is advised the item be disposed of as and asbestos contaminated materials Cement sheet Products (AC), NON LICENSED MATERIALs Works only by a competent ASBESTOS REMOVAL CONTRACTOR. Presume Positive Chrysotile. (AC). Sample/ ref: QSS11506/ 15 Location: Site D, WC Composite Cistern. Composite Cistern, NON LICENSED MATERIAL Works only by a competent ASBESTOS REMOVAL CONTRACTOR. Positive Amosite. (Composite). Intermittent sections of replacement profile cement roof sheets have been tested which returned negative results, please note it may not be cost effective in terms of separating these works from the Positive Sheet Removals. Locked Garages / NO ACCESS, as a large proportion of the units scheduled for demolition were not internally accessible due to being locked or access restricted by parked vehicles. There may be the potential for contaminated products to be present within as either left by previous occupants or alterations from the generic construct by others. It is advised that if suspect materials are identified within garages once all doors have been opened that these items are either presumed Positive and removed accordingly or further investigations / sampling be undertaken to confirm composition. Methods of examination throughout the site were restricted as units were still potentially occupied. See layout and data sheets Qube Environmental. Report No. QSS11506 Page 4 of 20

5 Client: Life Space Developments Ltd Date 30/01/2015 Targeted Refurbishment Survey Scope and Purpose 1.1 The Client has elected to commission Qube Environmental to undertake a Pre Demolition Survey to the above named premises to the areas identified on the drawing provided. 1.2 At the time of inspection the site was deemed as occupied as garage doors were locked and personal items present 1.3 We were advised that the aim of the survey was to locate and identify the presence of ACM s or suspected ACM s to the areas of proposed disturbance which include internal elements & external elements of the premises. 1.4 This report provides a record and assessment of the extent and characteristics of ACM s identified and is based on of the existing site conditions as found at the time of survey & the information made available as of the 22 nd January A Refurbishment / Pre-Demolition survey is as described below: Refurbishment / Pre-Demolition Survey (RFD survey) - Full Access sampling and identification survey. A full-access intrusive asbestos survey, extending the standard sampling asbestos survey, to include investigations into reasonably accessible sealed voids and the fabric of the building. An asbestos register is not included with this type of survey, as it is presumed that all asbestos materials identified are to be removed to facilitate refurbishment / demolition works. Due to the nature of the types of products which have utilized Asbestos as a constituent part there is still a possibility that some asbestos containing material may not be identified if they are in sealed voids or highly inaccessible areas. These may only be found at the time of demolition. 1.6 This particular survey comprised of a Targeted Refurbishment Assessment survey, carried out in accordance with the Health and Safety Executive s guidance document HSG 264 This means that: As far as reasonably practicable, locate and describe all ACM s in all reasonably accessible areas of the building within the constrains that the property is to remain occupied. A sampling programme is undertaken to identify possible ACM s and estimates of the volumes and the surface areas of ACM made. Qube Environmental. Report No. QSS11506 Page 5 of 20

6 Client: Life Space Developments Ltd Date 30/01/2015 Targeted Refurbishment Survey A record of the ACM s or where additional asbestos debris may be expected to be present. 1.7 The purpose of the report is to: Enable the client to take appropriate precautions so that people who working at the property are not exposed to asbestos-related health risks. Provide information to assist the client in developing and implementing an action plan for the further investigation, treatment, removal and/or monitoring of ACMs. Control of Asbestos Regulations 2012 (current edition) 1.8 The Control of Asbestos Regulations 2012 (CAR) apply to most work situations involving potential risk of exposure to asbestos. Since May 2004 the CAR will require that employers: Take all reasonable steps to identify the locations of materials likely to contain asbestos. Assume that the identified materials contain asbestos, unless there is evidence to the contrary. Keep an up to date written record (an Asbestos Register) of the location of asbestos-containing materials. Monitor the condition of asbestos-containing materials. Make a written assessment of the risk of exposure from asbestos. Prepare and implement a management plan to control asbestosrelated health risks, including measures to ensure that: material known or presumed to create a risk of exposure to asbestos is repaired or, if necessary, removed. material known or presumed to contain asbestos, but which does not pose a risk of exposure, is maintained in a good state of repair. information about the location and condition of material known or presumed to contain asbestos is given to anyone who is likely to disturb it. Other Health & Safety Regulations 1.9 Under Section 2 of the Health and Safety at Work etc. Act 1974 (HSWA), employers have a duty of care for the health, safety and welfare of their employees whilst at work. In addition, employers that are in control of Qube Environmental. Report No. QSS11506 Page 6 of 20

7 Client: Life Space Developments Ltd Date 30/01/2015 Targeted Refurbishment Survey premises have a duty of care, under Section 4 of the HSWA, towards all other people (non-employees) who use or work at their premises Other regulations embodied in the HSWA require employers to ensure that: Immediate steps are taken to reduce exposure to asbestos, in situations where the control level or action level is exceeded. Risk assessments are carried out and are used to prepare method statements for any work that is likely to involve exposure to asbestos. The number of workers exposed to asbestos is kept to a minimum. Information on the location of asbestos is made available to any person likely to be exposed to ACMs. Training is given to anyone liable to be exposed to asbestos This report can be used as a reference to assist the client in fulfilling its duties and obligations under present regulatory framework. Sources of Data Background Information 1.12 There is no current asbestos register available for these areas of this site at the time of inspection Information regarding the proposed works affecting this site were provided by Life Space Developments Ltd. Inspection, sampling and testing 1.14 After discussion with client in reference to site conditions, end client aims and the proposed works to the site. Mr A. Richardson on the 22 nd January 2015 carried out a restricted invasive inspection of the areas advised to be affected by the proposed demolition as per information supplied by the clients representative Mr Paul Preston The purpose of the inspection was to identify locations where the presence of asbestos is suspected, and to make arrangements for the recovery and testing of representative samples Based on the findings of the restricted invasive inspection carried out on the 22 nd January 2015, SIXTEEN representative bulk samples of materials were recovered from the site. During the sampling process, care was taken to verify that the recovered samples were representative of the situation and the medium in which asbestos contamination was suspected. The sampling protocol that was used is as specified in HSG 264. Qube Environmental. Report No. QSS11506 Page 7 of 20

8 Client: Life Space Developments Ltd Date 30/01/2015 Targeted Refurbishment Survey 1.17 The recovered samples were subsequently examined in a UKAS Accredited laboratory to establish their asbestos content, in accordance with HSG248 Asbestos: The Analysts Guide, published by the Health & Safety Executive The results of the laboratory testing for all recovered samples are presented at Appendix A All areas identified as affected on the information supplied by the client and their representatives on the 22 nd January 2015 were representatively inspected where accessible and safe to do so. Areas of the buildings which have not been inspected should be presumed to contain ACM s until proved otherwise. Presentation of Findings Data Sheets 1.20 Data sheet for the sampled materials have been prepared. These data sheets are presented in Appendix A Figures where applicable are presented at the rear of this document. These include photo reports, data sheets and layout representations. Representative Sampling 1.22 Every attempt has been made to ensure that representative samples of materials suspected of containing asbestos have been recovered for testing purposes. Nevertheless, where the laboratory results of analysis (shown in Appendix A) indicate that no asbestos has been detected, caution should be exercised in extrapolating the same conclusion to the parent material. Where doubt remains, further sampling and testing should be carried out. As investigation techniques were restricted it is still possible for hidden asbestos materials to be present. During works care should be taken and any future suspect material must be Presumed to be Positive and removed accordingly or works should cease and conformation of the suspected materials composition be sort. Qube Environmental. Report No. QSS11506 Page 8 of 20

9 Client: Life Space Developments Ltd Date 30/01/2015 Targeted Refurbishment Survey Risk Classification Not Applicable to Pre-demolition / refurbishment Surveys as any found materials Positive for asbestos contamination within the proposed works are to be removed by a suitably competent contractor The data sheets for materials and areas of examination are contained within Appendix A. Assessments of risk and provide recommendations concerning access restrictions that should be imposed and priorities for treatment of suspected asbestos-containing materials are not applicable to this survey. Any material identified as positive for asbestos contamination should be removed from site by competent None Licensed / Licensed contractors (the type of removal criteria required is material dependant). Report Format Text 1.24 Remaining sections of text are structured as follows: Section 2 Describes the current buildings and their uses. Section 3 Describes the survey work carried out. Section 4 Describes the procedure used to assess suspected asbestos-containing materials and provides an overview of the nature and extent of suspected asbestoscontaining materials. Section 5 Provides recommendations for action plans to address the issues identified in the report. Appendices 1.25 The following Appendices provide details of the factual data obtained during the inspection and survey work and the results of the assessments that have been made. Appendix A Contains copies of the results of laboratory analyses by the UKAS Accredited Laboratory. Contains Data Sheets that summarise the information obtained from the visual inspection, sampling and testing work carried out. Layout representations showing areas of materials identified as positive for asbestos contamination. Qube Environmental. Report No. QSS11506 Page 9 of 20

10 Client: Life Space Developments Ltd Date 30/01/2015 Targeted Refurbishment Survey Figures 1.26 Figure where applicable should be read in conjunction with the data sheet provided at Appendix A. 2.0 Site Description Site History 2.1 The affected areas of the site were person vacant at the time of inspection however it was advised that as all areas were not open and accessible and that those examined where open still included personal belongings and materials (cars) site would remain presumed to still be occupied post survey. Therefore restricted investigation methods were utilized. Areas showing commonality of construction were representatively inspected where safe to do so. 3.0 Investigations Inspection, Sampling and Analysis Inspection 3.1 Examination & restricted methods of inspection of the areas of proposed disturbance to the fabric of the buildings identified in the pre survey discussions with the clients representative Mr Paul Preston were carried out by Mr A Richardson on 22 nd January This involved where safe to do so, the invasive examination of the areas we have been advised will be affected by the proposed works. Sampling and Analysis 3.2 Sampling of materials was carried out on the 22 nd January 2015 in accordance with the method specified in HSG Access to the buildings was arranged via the client. 3.4 Photographs were taken to provide a record of all of the locations and materials examined. A photographic record of the inspection is incorporated in the data sheets in Appendix A 3.5 Analysis of the recovered samples was carried out by Athena Environmental Solutions Ltd in accordance with the procedure specified in HSG248 Asbestos: The Analysts Guide, published by the Health & Safety Executive. This laboratory is accredited by the United Kingdom Accreditation Service (UKAS) for the identification of asbestos in bulk samples. Qube Environmental. Report No. QSS11506 Page 10 of 20

11 Client: Life Space Developments Ltd Date 30/01/2015 Targeted Refurbishment Survey Results of Laboratory Testing 3.6 Results obtained from the analysis of the recovered samples are provided in Appendix A. Significance of Laboratory Test Results 3.7 The following are the three main types of asbestos identified by the laboratory testing procedure, and recorded on the laboratory result sheets in Appendix A: Chrysotile Amosite Crocidolite White Asbestos Brown Asbestos Blue Asbestos 3.8 The analysis of the samples can also identify the presence of nonasbestos material fibres, and the presence of these is indicated in Appendix B where appropriate, using the sub-divisions: Organic MMMF Organic fibres, such as animal hair Man Made Mineral Fibre, such as fibre glass 3.9 It is emphasised that all types of asbestos, irrespective of their mineralogical compositions and concentration levels, fall within the scope of the Control of Asbestos Regulations (see Section 1). Therefore, details of the type and quantity of asbestos materials identified by the laboratory analyses do not significantly affect the Duty Holders legal duties and obligations. However, they do influence the assessment of risk, and therefore assist in determining the priorities for remedial action. Areas surveyed /excluded from the survey 3.10 The invasive inspection and survey were to the structures of the premises which are the responsibility of the client as far as we have been advised. Any Additional areas of the site and Ground and drain investigation are outside of the remit of this survey 3.11 Representative invasive inspections were made to areas of common construction and those reflecting the overall conditions of areas affected by the proposed works No investigations were made to areas which fall outside of those identified by the client as being affected by the proposed works Where areas of no safe access exist or items are still deemed live or occupied it is recommended that when safe access is possible further investigations are undertaken. Qube Environmental. Report No. QSS11506 Page 11 of 20

12 Client: Life Space Developments Ltd Date 30/01/2015 Targeted Refurbishment Survey 4.0 Assessment and Overview Risk Assessment Methodology Product Type The Product Type or product debris is classified into one of the following: 1 Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints or decorative finishes, asbestos cement, etc.). 2 Asbestos insulating board, mill board, other low density insulation board, asbestos textiles, gaskets, rope and woven textiles, asbestos paper and felt. Thermal insulation (e.g. pipe and boiler lagging), sprayed 3 asbestos, loose asbestos, asbestos mattresses and packing. Material Condition (NOT APPLICABLE) any items identified as positive which will be disturbed during works are to be removed prior to refurbishment / demolition. Surface Treatment (NOT APPLICABLE) any items identified as positive are to be removed prior to refurbishment / demolition. Asbestos Type 4.1 For the purpose of the risk assessments described here, the Asbestos Type is classified as follows: 1 Chrysotile 2 Amphibole excluding Crocidolite 3 Crocidolite Qube Environmental. Report No. QSS11506 Page 12 of 20

13 Client: Life Space Developments Ltd Date 30/01/2015 Targeted Refurbishment Survey Data Sheets 4.2 For the purpose of a Pre-demolition/Refurbishment survey material risk and priority scoring are NOT APPLICABLE, as any materials identified will require removal as they will be disturbed by the prescribed works. 4.3 The reader is reminded of the significance of the colour coding that is adopted on the Data Sheets, as follows: Green Laboratory analysis shows that asbestos is not present in the recovered sample. Red Laboratory analysis shows that asbestos is present in the recovered sample. Yellow No laboratory analysis has been carried out because it was not possible to recover a sample at this location and it is considered likely that asbestos is present. Qube Environmental. Report No. QSS11506 Page 13 of 20

14 Client: Life Space Developments Ltd Date 30/01/2015 Targeted Refurbishment Survey Overview 4.4 The remainder of this Section provides an overview of the situation based on the results of samples taken and the visual examination of the areas exposed during the invasive inspection to the advised affected areas of the site. 4.5 We have been advised by the clients representatives that the proposed works consist of demolition of garages located to this site and the building previously serving as the area Depot / lock up Yard. 4.6 The remit of this survey was to the affected areas as discussed with the client and confirmed on site layout drawing provided by the client. No investigations of areas outside of these locations to this building were undertaken. 4.7 Invasive investigations were of a restricted in that not all garages were internally accessible, it was also identified that personal items were still present within some of the accessible units. 4.8 Materials POSITIVE for asbestos contamination have been identified during this investigation as follows (also see site layout and data sheets): Findings. 4.9 Sample/ ref: QSS11506/ 14 & 16 Location: Site D. ALL Depot internal ceiling boards. Asbestos Insulation boards (AIB) Fully LICENSED MATERIAL, HIGH RISK PRODUCT. Works only by a LICENSED ASBESTOS REMOVAL CONTRACTOR under fully controlled conditions. 14 day notification to HSE required. Positive: Amosite & Chrysotile. (AIB). (Brown & White Asbestos) 4.10 Sample/ ref: QSS11506/ 2,3,5,6,9,10,11 & 12 Location: Sites C & D. Majority of Garages, cement profile roof sheets. Cement sheet Products (AC), NON LICENSED MATERIALs Works only by a competent ASBESTOS REMOVAL CONTRACTOR. Positive Chrysotile. (AC). Qube Environmental. Report No. QSS11506 Page 14 of 20

15 Client: Life Space Developments Ltd Date 30/01/2015 Targeted Refurbishment Survey 4.11 Sample/ ref: QSS11506/ 1 Location: Sites C. Garage 199 (quantity of cement product debris on sofa). Although the sample for the above item returned negative on analysis it is still possible that some contaminated materials may be present within the pile of debris. Therefore, for compliance purposes it is advised the item be disposed of as and asbestos contaminated materials Cement sheet Products (AC), NON LICENSED MATERIALs Works only by a competent ASBESTOS REMOVAL CONTRACTOR. Presume Positive Chrysotile. (AC) Sample/ ref: QSS11506/ 15 Location: Site D, WC Composite Cistern. Composite Cistern, NON LICENSED MATERIAL Works only by a competent ASBESTOS REMOVAL CONTRACTOR. Positive Amosite. (Composite) Intermittent sections of replacement profile cement roof sheets have been tested which returned negative results, please note it may not be cost effective in terms of separating these works from the Positive Sheet Removals Locked Garages / NO ACCESS, as a large proportion of the units scheduled for demolition were not internally accessible due to being locked or access restricted by parked vehicles. There may be the potential for contaminated products to be present within as either left by previous occupants or alterations from the generic construct by others. It is advised that if suspect materials are identified within garages once all doors have been opened that these items are either presumed Positive and removed accordingly or further investigations / sampling be undertaken to confirm composition Methods of examination throughout the site were restricted as units were still potentially occupied /accessible to the general public See layout and data sheets Qube Environmental. Report No. QSS11506 Page 15 of 20

16 Client: Life Space Developments Ltd Date 30/01/2015 Targeted Refurbishment Survey 4.17 Site Summary Investigations to this site showed: Garage Blocks Site C & D Conventional half brick wall construction to sides and open rear ends of garage blocks. No evident DPM to low level brick works. Half Brick walls forming a cavity to the concrete sectional constructed garage walls which are steel reinforced. Concrete slab bases Front Gutters lines in cast concrete forming section of the steel reinforced concrete front frame works. Metal up & over garage doors, where internal inspection possible no insulated liners were evident. Concrete steel reinforced roof joists In the majority Asbestos cement profile roof sheeting forming garage roofs. Sections (individual garage units) with plywood board and bitumen felt over roofing (profile cement sheets still evident below) Alloy verge edges to descending elevations to garages. Modern Bitumen & Alloy adhesive flashings. Cement product debris within garage 199 Contents: Personal belongings including suit cases, ladders, fire extinguishers and documents etc were present within accessible units. The majority of garage units were locked or obstructed, layout diagram show N/A indicating no internal access to garage. Site D Depot building / yard. Bitumen Felt & plywood roof with timber fascia s Brick wall construct over concrete slab, timber doors and frames with no evident packers and concrete lintels over doorways. Asbestos Insulation Board ceiling boards through all rooms of the depot building. This is a fully LICENSED MATERIAL requiring removal under fully controlled conditions. Asbestos composite cistern to WC Timber doors and windows Qube Environmental. Report No. QSS11506 Page 16 of 20

17 Client: Life Space Developments Ltd Date 30/01/2015 Targeted Refurbishment Survey 4.18 Throughout the identified areas as of the site, representative restricted invasive examinations were undertaken to the safely accessible locations. See layout diagram Although the presence of asbestos in a number of areas has not been confirmed, caution should be exercised if any works are carried out. If any suspect materials are encountered in these areas, it is recommended that all works are stopped and the area evacuated until such time that the material can be sampled, analysed and confirmed to be free of any asbestos. 5.0 Conclusions & Recommendations Additional Inspection, Sampling and Testing 5.1 We recommend that further inspection, sampling and testing is carried out in areas that are not covered by the inspection work described in Sections 1 and 4 above. These fall into the following categories: (a) (b) Building/s and areas which do not fall under the remit of this survey. Garages to which no internal access was possible. 5.2 Recommendations: Building All Garages and materials identified internal which are potential asbestos contaminated products should be either presumed and removed as such or samples taken and there composition confirmed. If scope of works is altered, additional areas not covered by this report will require examination. If further concealed potentially suspect materials become evident during demolition works these should be sampled to confirm composition Area All Qube Environmental. Report No. QSS11506 Page 17 of 20

18 Client: Life Space Developments Ltd Date 30/01/2015 Targeted Refurbishment Survey Areas Excluded from the Survey 5.3 During the survey the following areas were excluded from the survey because they were found to be either inaccessible due to the physical nature of the premises; the extraction of samples would have affected the functional integrity of the article or where access could have endangered the surveyor or the general public as units (Garages) are not sectioned off at the time of inspection: Hidden / concealed Areas / voids beyond the scope of this survey which exceeds the areas of proposed alterations as advised by the client and their representatives which would require substantial demolition to be undertaken to expose their position. 5.4 Although the presence of asbestos in these areas has not been confirmed, caution should be exercised if any works are carried out there in the future. If any suspect materials are encountered in these areas, it is recommended that all works are stopped and the area evacuated until such time that the material can be sampled, analysed and confirmed to be free of any asbestos. 6.0 Caveats 6.1 All reasonable steps have been taken to ensure that the contents and findings of this report are true and accurate based on the restriction imposed by the nature of the works contract. Though as stated below, further undetected ACM s may still be present within the premises. The client should therefore be aware of his responsibilities for identifying, locating, removing and/or managing all ACM s within the premises, and for notifying the appropriate authorities where necessary. Pre-demolition / refurbishment survey. 6.2 This type of survey employs the use of destructive sampling techniques of an unfamiliar site. Although every effort is made to locate all asbestos containing materials, it is impossible to rule out the possibility that undiscovered asbestos materials may be present. If the building is to undergo further major refurbishment or demolition, it is recommended that the persons carrying out the work are made aware of this and take sufficient precautions, as may be appropriate, to ensure the health and safety of their own employees and any other parties who may be affected by the works. Qube Environmental. Report No. QSS11506 Page 18 of 20

19 Client: Life Space Developments Ltd Date 30/01/2015 Targeted Refurbishment Survey 7.0 References (1) HSG 264 Asbestos : The survey Guide. HSE Books (2) Asbestos Essentials HSE Books (3) MDHS 100: Surveying, Sampling and Assessment of Asbestoscontaining Materials. Methods for the Determination of Hazardous Materials, HSE Books (4) HSG248 Asbestos: Asbestos: The analysts' guide for sampling, analysis and clearance procedures, HSE Books (5) A Comprehensive Guide to Managing Asbestos in Premises HSG 227, HSE Books (6) The Control of Asbestos Regulations 2012 The Stationary Office (7) Approved Code of Practice The Management of Asbestos in Non- Domestic Premises. Approved Code of Practice (L127) HSE Books Qube Environmental. Report No. QSS11506 Page 19 of 20

20 Client: Life Space Developments Ltd Date 30/01/2015 Targeted Refurbishment Survey Appendix A Results of Laboratory Testing UKAS Accredited Test Certificate, Data sheets and layout diagrams Qube Environmental. Report No. QSS11506 Page 20 of 20

21 4696 CERTIFICATE OF IDENTIFICATION OF ASBESTOS FIBRES SITE ADDRESS: CLIENT ADDRESS SITES C AND D, BOUNDARY WAY, WATFORD, WD25 SITE REF NO QUBE SOLUTION SERVICES LTD THE WARREN NEWCASTLE ROAD COTES HEATH STAFFORD STAFFORDSHIRE ST21 6RX PHONE NUMBER CERTIFICATE NUMBER ATH/15/01/1220 DATE SAMPLED 22/01/15 DATE RECEIVED 26/01/15 DATE ANALYSED 26/01/15 NO. OF SAMPLES 16 PAGE NUMBER 1 OF 1 OBTAINED DELIVERED SAMPLE NUMBER CLIENT NUMBER SAMPLE LOCATION MATERIAL TYPE FIBRE TYPE DETECTED 1 1 DEBRIS GARAGE 199 INTERNAL - CEMENT CEMENT NADIS 2 2 GARAGE 199 ROOF SHEETS - CEMENT CEMENT CHRYSOTILE 3 3 GARAGE 197 ROOF SHEETS - CEMENT CEMENT CHRYSOTILE 4 4 GARAGE 203 ROOF SHEETS - CEMENT CEMENT NADIS 5 5 GARAGE 200 ROOF SHEETS - CEMENT CEMENT CHRYSOTILE 6 6 GARAGES ROOF SHEETS - CEMENT CEMENT CHRYSOTILE GARAGE 210 FELT ROOFING - BITUMEN BITUMEN NADIS GARAGE 211 ROOF SHEETS - CEMENT CEMENT NADIS GARAGES ROOF SHEETS - CEMENT CEMENT CHRYSOTILE GARAGES ROOF SHEETS - CEMENT CEMENT CHRYSOTILE GARAGES ROOF SHEETS - CEMENT CEMENT CHRYSOTILE SITE D GARAGES ROOF SHEETS - CEMENT CEMENT CHRYSOTILE SITE D THE DEPOT EXTERNAL ROOF FELT - BITUMEN BITUMEN NADIS SITE D THE DEPOT MAIN CEILING AREA INSULATING BOARD INSULATING BOARD AMOSITE/CHRYSOTILE SITE D THE DEPOT WC CISTERN - COMPOSITE COMPOSITE AMOSITE SITE D THE DEPOT REAR RIGHT HAND SIDE ROOM CEILING INSULATING BOARD AMOSITE/CHRYSOTILE INSULATING BOARD KEY: CHRYSOTILE WHITE ASBESTOS CROCIDOLITE BLUE ASBESTOS AMOSITE - BROWN ASBESTOS NADIS - NO ASBESTOS DETECTED IN SAMPLE TREMOLITE, ANTHOPHYLLITE & ACTINOLITE LESS COMMON ASBESTOS FIBRE TYPES Note: When a trace of asbestos fibres are reported this represents one or two fibres only. Note: The material type reported is an opinion of the analyst only and does not form part of the ATHENA UKAS accreditation. Note: Samples will be kept for a minimum of 6 months. Note: This Certificate of Identification of Asbestos Fibres can only be reproduced in full unless written approval from Athena has been obtained. ANALYST NAME AND SIGNATURE: AUTHORISER NAME AND SIGNATURE: Samples have been analysed to determine the presence of asbestos fibres using Athena Environmental Solutions in house method of polarised light microscopy and central stop dispersion staining based on HSG 248. Where samples have been delivered the site address and sample locations are given by the client and Athena are not responsible for the accuracy or competence of these details or of the sampling. BULK 001 VERSION 3 26/06/13 SUITE 3, SOPWITH HOUSE, HURRICANE WAY, WICKFORD, ESSEX, SS11 8YU Tel: Fax: info@athena-env.co.uk Company Reg Number: Registered Address: 3 Sandhurst Crescent, Leigh-on-sea, Essex, SS9 4AL

22 ASBESTOS DATA SHEET Created By JR Date 24-Jan-15 Plus AsbestaPLANPlus Asbestos Survey, Management & Risk Analysis Software Unique Sample/Ref No. S001 Company Name LIFE SPACE DEVELPOMENTS LTD Site Photograph/Plan Site Reference Building Ref QSS11506 Site C Garage 199 Address SITES C & D BOUNDARY WAY WATFORD Level/Floor Internal Debris WD25 7HY Room/Area Debris on sofa Description of Location Product Description cement flue / vent pipe smashed cement debris Survey Date 22-Jan-15 Survey Type DEMOLITION SURVEY Estimated Quantity (m2) 2 Comments Cement debris NADIS No asbestos detected in sample. As sample is taken from debris pile it is possible that some materials may be positive within. It is advised that this item be removed as AC debris Non Licensed to ensure Compliance. Lead Surveyor's Name Name of Testing Laboratory Survey Company Name Occupant Activity Disturbance (Accessibility) Disturbance (Extent) Disturbance (Location) Exposure (Usage Time) A R RICHARDSON ATHENA QUBE ENVIRONMENTAL Asbestos Confirmed Asbestos Assumed No Asbestos Detected Material Assessment Score: Priority Assessment Score: TOTAL ASSESSMENT SCORE: Click here for notes on risk assessment and scores Product Type Extent of Damage Surface Treatment Asbestos Type Exposure (Freq of Use) Exposure (No of Occupants) Maintenance (Frequency of) Maintenance (Type of) Proposed Action Remove Estimated Cost 0.00 Action Completed Review Date

23 ASBESTOS DATA SHEET Created By JR Date 24-Jan-15 Plus AsbestaPLANPlus Asbestos Survey, Management & Risk Analysis Software Unique Sample/Ref No. S002 Company Name LIFE SPACE DEVELPOMENTS LTD Site Photograph/Plan Site Reference Building Ref QSS11506 Site C Garage 199 Address SITES C & D BOUNDARY WAY WATFORD Level/Floor Roof Construct WD25 7HY Room/Area Roof Description of Location Product Description Roof construct, profile cement sheets Survey Date 22-Jan-15 Survey Type DEMOLITION SURVEY Estimated Quantity (m2) 12 Comments Cement Positive Chrysotile (White Asbestos) Non Licensed materials Lead Surveyor's Name Name of Testing Laboratory Survey Company Name Occupant Activity Disturbance (Accessibility) Disturbance (Extent) Disturbance (Location) Exposure (Usage Time) A R RICHARDSON ATHENA QUBE ENVIRONMENTAL Asbestos Confirmed Asbestos Assumed No Asbestos Detected Material Assessment Score: 5 Priority Assessment Score: TOTAL ASSESSMENT SCORE: Click here for notes on risk assessment and scores Product Type Boarding, Textiles, Gaskets, P Exposure (Freq of Use) Proposed Action Remove Extent of Damage Low Damage Exposure (No of Occupants) Estimated Cost 0.00 Surface Treatment Cement, Enclosed sprays/lagg Maintenance (Frequency of) Action Completed Asbestos Type Chrysotile (White) Maintenance (Type of) Review Date

24 ASBESTOS DATA SHEET Created By JR Date 24-Jan-15 Plus AsbestaPLANPlus Asbestos Survey, Management & Risk Analysis Software Unique Sample/Ref No. S003 Company Name LIFE SPACE DEVELPOMENTS LTD Site Photograph/Plan Site Reference Building Ref QSS11506 Site C Garage 197 Address SITES C & D BOUNDARY WAY WATFORD Level/Floor Roof Construct WD25 7HY Room/Area Roof Description of Location Product Description Roof construct, profile cement sheets Survey Date 22-Jan-15 Survey Type DEMOLITION SURVEY Estimated Quantity (m2) 12 Comments Cement Positive Chrysotile (White Asbestos) Non Licensed materials Lead Surveyor's Name Name of Testing Laboratory Survey Company Name Occupant Activity Disturbance (Accessibility) Disturbance (Extent) Disturbance (Location) Exposure (Usage Time) A R RICHARDSON ATHENA QUBE ENVIRONMENTAL Asbestos Confirmed Asbestos Assumed No Asbestos Detected Material Assessment Score: 5 Priority Assessment Score: TOTAL ASSESSMENT SCORE: Click here for notes on risk assessment and scores Product Type Boarding, Textiles, Gaskets, P Exposure (Freq of Use) Proposed Action Remove Extent of Damage Low Damage Exposure (No of Occupants) Estimated Cost 0.00 Surface Treatment Cement, Enclosed sprays/lagg Maintenance (Frequency of) Action Completed Asbestos Type Chrysotile (White) Maintenance (Type of) Review Date

25 ASBESTOS DATA SHEET Created By JR Date 24-Jan-15 Plus AsbestaPLANPlus Asbestos Survey, Management & Risk Analysis Software Unique Sample/Ref No. S004 Company Name LIFE SPACE DEVELPOMENTS LTD Site Photograph/Plan Site Reference Building Ref QSS11506 Site C Garage 203 Address SITES C & D BOUNDARY WAY WATFORD Level/Floor Roof Construct WD25 7HY Room/Area Roof Description of Location Product Description Roof construct profile roof sheets Survey Date 22-Jan-15 Survey Type DEMOLITION SURVEY Estimated Quantity (m2) 12 Comments NADIS NEGATIVE Cement NO ASBESTOS DETECTED IN SAMPLE Lead Surveyor's Name Name of Testing Laboratory Survey Company Name Occupant Activity Disturbance (Accessibility) Disturbance (Extent) Disturbance (Location) Exposure (Usage Time) A R RICHARDSON ATHENA QUBE ENVIRONMENTAL Asbestos Confirmed Asbestos Assumed No Asbestos Detected Material Assessment Score: Priority Assessment Score: TOTAL ASSESSMENT SCORE: Click here for notes on risk assessment and scores Product Type Extent of Damage Surface Treatment Asbestos Type Exposure (Freq of Use) Exposure (No of Occupants) Maintenance (Frequency of) Maintenance (Type of) Proposed Action Estimated Cost 0.00 Action Completed Review Date

26 ASBESTOS DATA SHEET Created By JR Date 24-Jan-15 Plus AsbestaPLANPlus Asbestos Survey, Management & Risk Analysis Software Unique Sample/Ref No. S005 Company Name LIFE SPACE DEVELPOMENTS LTD Site Photograph/Plan Site Reference Building Ref QSS11506 Site C Garage 200 Address SITES C & D BOUNDARY WAY WATFORD Level/Floor Roof Construct WD25 7HY Room/Area Roof Description of Location Product Description Roof construct profile roof sheets Survey Date 22-Jan-15 Survey Type DEMOLITION SURVEY Estimated Quantity (m2) 12 Comments Cement Positive Chrysotile (White Asbestos) Non Licensed materials Lead Surveyor's Name Name of Testing Laboratory Survey Company Name Occupant Activity Disturbance (Accessibility) Disturbance (Extent) Disturbance (Location) Exposure (Usage Time) A R RICHARDSON ATHENA QUBE ENVIRONMENTAL Asbestos Confirmed Asbestos Assumed No Asbestos Detected Material Assessment Score: 5 Priority Assessment Score: TOTAL ASSESSMENT SCORE: Click here for notes on risk assessment and scores Product Type Boarding, Textiles, Gaskets, P Exposure (Freq of Use) Proposed Action Remove Extent of Damage Low Damage Exposure (No of Occupants) Estimated Cost 0.00 Surface Treatment Cement, Enclosed sprays/lagg Maintenance (Frequency of) Action Completed Asbestos Type Chrysotile (White) Maintenance (Type of) Review Date

27 ASBESTOS DATA SHEET Created By JR Date 24-Jan-15 Plus AsbestaPLANPlus Asbestos Survey, Management & Risk Analysis Software Unique Sample/Ref No. S006 Company Name LIFE SPACE DEVELPOMENTS LTD Site Photograph/Plan Site Reference Building Ref QSS11506 Site C Garage 205 to 209 Address SITES C & D BOUNDARY WAY WATFORD Level/Floor Roof Construct WD25 7HY Room/Area Roof Description of Location Product Description Roof construct profile roof sheets all showing commonality of finish Survey Date 22-Jan-15 Survey Type DEMOLITION SURVEY Estimated Quantity (m2) 60 Comments Cement Positive Chrysotile (White Asbestos) Non Licensed materials Lead Surveyor's Name Name of Testing Laboratory Survey Company Name Occupant Activity Disturbance (Accessibility) Disturbance (Extent) Disturbance (Location) Exposure (Usage Time) A R RICHARDSON ATHENA QUBE ENVIRONMENTAL Asbestos Confirmed Asbestos Assumed No Asbestos Detected Material Assessment Score: 5 Priority Assessment Score: TOTAL ASSESSMENT SCORE: Click here for notes on risk assessment and scores Product Type Boarding, Textiles, Gaskets, P Exposure (Freq of Use) Proposed Action Remove Extent of Damage Low Damage Exposure (No of Occupants) Estimated Cost 0.00 Surface Treatment Cement, Enclosed sprays/lagg Maintenance (Frequency of) Action Completed Asbestos Type Chrysotile (White) Maintenance (Type of) Review Date

28 ASBESTOS DATA SHEET Created By JR Date 24-Jan-15 Plus AsbestaPLANPlus Asbestos Survey, Management & Risk Analysis Software Unique Sample/Ref No. S007 Company Name LIFE SPACE DEVELPOMENTS LTD Site Photograph/Plan Site Reference Building Ref QSS11506 Site C Garage 210 Address SITES C & D BOUNDARY WAY WATFORD Level/Floor Roof Construct WD25 7HY Room/Area FELT Roof Description of Location Product Description Roof construct ply wood board & bitumen felt over cement profile sheet Survey Date 22-Jan-15 Survey Type DEMOLITION SURVEY Estimated Quantity (m2) 12 Comments NADIS. Cement Cemnt roof sheets under boarding show commonality of finish to majority of roof constructs. Presume AC sheets. Lead Surveyor's Name Name of Testing Laboratory Survey Company Name Occupant Activity Disturbance (Accessibility) Disturbance (Extent) Disturbance (Location) Exposure (Usage Time) A R RICHARDSON ATHENA QUBE ENVIRONMENTAL Asbestos Confirmed Asbestos Assumed No Asbestos Detected Material Assessment Score: Priority Assessment Score: TOTAL ASSESSMENT SCORE: Click here for notes on risk assessment and scores Product Type Extent of Damage Surface Treatment Asbestos Type Exposure (Freq of Use) Exposure (No of Occupants) Maintenance (Frequency of) Maintenance (Type of) Proposed Action Estimated Cost 0.00 Action Completed Review Date

29 ASBESTOS DATA SHEET Created By JR Date 24-Jan-15 Plus AsbestaPLANPlus Asbestos Survey, Management & Risk Analysis Software Unique Sample/Ref No. S008 Company Name LIFE SPACE DEVELPOMENTS LTD Site Photograph/Plan Site Reference Building Ref QSS11506 Site C Garage 211 Address SITES C & D BOUNDARY WAY WATFORD Level/Floor Roof Construct WD25 7HY Room/Area Roof Description of Location Product Description Roof construct profile roof sheets Survey Date 22-Jan-15 Survey Type DEMOLITION SURVEY Estimated Quantity (m2) 12 Comments NADIS NEGATIVE Cement NO ASBESTOS DETECTED IN SAMPLE Lead Surveyor's Name Name of Testing Laboratory Survey Company Name Occupant Activity Disturbance (Accessibility) Disturbance (Extent) Disturbance (Location) Exposure (Usage Time) A R RICHARDSON ATHENA QUBE ENVIRONMENTAL Asbestos Confirmed Asbestos Assumed No Asbestos Detected Material Assessment Score: Priority Assessment Score: TOTAL ASSESSMENT SCORE: Click here for notes on risk assessment and scores Product Type Extent of Damage Surface Treatment Asbestos Type Exposure (Freq of Use) Exposure (No of Occupants) Maintenance (Frequency of) Maintenance (Type of) Proposed Action Estimated Cost 0.00 Action Completed Review Date

30 ASBESTOS DATA SHEET Created By JR Date 24-Jan-15 Plus AsbestaPLANPlus Asbestos Survey, Management & Risk Analysis Software Unique Sample/Ref No. S009 Company Name LIFE SPACE DEVELPOMENTS LTD Site Photograph/Plan Site Reference Building Ref QSS11506 Site C Garage Address SITES C & D BOUNDARY WAY WATFORD Level/Floor Roof Construct WD25 7HY Room/Area Roof Description of Location Product Description Roof construct profile roof sheets Survey Date 22-Jan-15 Survey Type DEMOLITION SURVEY Estimated Quantity (m2) 24 Comments Cement Positive Chrysotile (White Asbestos) Non Licensed materials Lead Surveyor's Name Name of Testing Laboratory Survey Company Name Occupant Activity Disturbance (Accessibility) Disturbance (Extent) Disturbance (Location) Exposure (Usage Time) A R RICHARDSON ATHENA QUBE ENVIRONMENTAL Asbestos Confirmed Asbestos Assumed No Asbestos Detected Material Assessment Score: 5 Priority Assessment Score: TOTAL ASSESSMENT SCORE: Click here for notes on risk assessment and scores Product Type Boarding, Textiles, Gaskets, P Exposure (Freq of Use) Proposed Action Remove Extent of Damage Low Damage Exposure (No of Occupants) Estimated Cost 0.00 Surface Treatment Cement, Enclosed sprays/lagg Maintenance (Frequency of) Action Completed Asbestos Type Chrysotile (White) Maintenance (Type of) Review Date

31 ASBESTOS DATA SHEET Created By JR Date 24-Jan-15 Plus AsbestaPLANPlus Asbestos Survey, Management & Risk Analysis Software Unique Sample/Ref No. S010 Company Name LIFE SPACE DEVELPOMENTS LTD Site Photograph/Plan Site Reference Building Ref QSS11506 Site C Garage Address SITES C & D BOUNDARY WAY WATFORD Level/Floor Roof Construct WD25 7HY Room/Area Roof Description of Location Product Description Roof construct profile roof sheets Survey Date 22-Jan-15 Survey Type DEMOLITION SURVEY Estimated Quantity (m2) 60 Comments Cement Positive Chrysotile (White Asbestos) Non Licensed materials Lead Surveyor's Name Name of Testing Laboratory Survey Company Name Occupant Activity Disturbance (Accessibility) Disturbance (Extent) Disturbance (Location) Exposure (Usage Time) A R RICHARDSON ATHENA QUBE ENVIRONMENTAL Asbestos Confirmed Asbestos Assumed No Asbestos Detected Material Assessment Score: 5 Priority Assessment Score: TOTAL ASSESSMENT SCORE: Click here for notes on risk assessment and scores Product Type Boarding, Textiles, Gaskets, P Exposure (Freq of Use) Proposed Action Remove Extent of Damage Low Damage Exposure (No of Occupants) Estimated Cost 0.00 Surface Treatment Cement, Enclosed sprays/lagg Maintenance (Frequency of) Action Completed Asbestos Type Chrysotile (White) Maintenance (Type of) Review Date

32 ASBESTOS DATA SHEET Created By JR Date 24-Jan-15 Plus AsbestaPLANPlus Asbestos Survey, Management & Risk Analysis Software Unique Sample/Ref No. S011 Company Name LIFE SPACE DEVELPOMENTS LTD Site Photograph/Plan Site Reference Building Ref QSS11506 Site C Garage Address SITES C & D BOUNDARY WAY WATFORD Level/Floor Roof Construct WD25 7HY Room/Area Roof Description of Location Product Description Roof construct profile roof sheets Survey Date 22-Jan-15 Survey Type DEMOLITION SURVEY Estimated Quantity (m2) 84 Comments Cement Positive Chrysotile (White Asbestos) Non Licensed materials Lead Surveyor's Name Name of Testing Laboratory Survey Company Name Occupant Activity Disturbance (Accessibility) Disturbance (Extent) Disturbance (Location) Exposure (Usage Time) A R RICHARDSON ATHENA QUBE ENVIRONMENTAL Asbestos Confirmed Asbestos Assumed No Asbestos Detected Material Assessment Score: 5 Priority Assessment Score: TOTAL ASSESSMENT SCORE: Click here for notes on risk assessment and scores Product Type Boarding, Textiles, Gaskets, P Exposure (Freq of Use) Proposed Action Remove Extent of Damage Low Damage Exposure (No of Occupants) Estimated Cost 0.00 Surface Treatment Cement, Enclosed sprays/lagg Maintenance (Frequency of) Action Completed Asbestos Type Chrysotile (White) Maintenance (Type of) Review Date

33 ASBESTOS DATA SHEET Created By JR Date 24-Jan-15 Plus AsbestaPLANPlus Asbestos Survey, Management & Risk Analysis Software Unique Sample/Ref No. S012 Company Name LIFE SPACE DEVELPOMENTS LTD Site Photograph/Plan Site Reference Building Ref QSS11506 Site D Garage Address SITES C & D BOUNDARY WAY WATFORD Level/Floor Roof Construct WD25 7HY Room/Area Roof Description of Location Product Description Roof construct profile roof sheets Survey Date 22-Jan-15 Survey Type DEMOLITION SURVEY Estimated Quantity (m2) 120 Comments Cement Positive Chrysotile (White Asbestos) Non Licensed materials roof sheets show commonality of finish under felt repairs Lead Surveyor's Name Name of Testing Laboratory Survey Company Name Occupant Activity Disturbance (Accessibility) Disturbance (Extent) Disturbance (Location) Exposure (Usage Time) A R RICHARDSON ATHENA QUBE ENVIRONMENTAL Asbestos Confirmed Asbestos Assumed No Asbestos Detected Material Assessment Score: 5 Priority Assessment Score: TOTAL ASSESSMENT SCORE: Click here for notes on risk assessment and scores Product Type Boarding, Textiles, Gaskets, P Exposure (Freq of Use) Proposed Action Remove Extent of Damage Low Damage Exposure (No of Occupants) Estimated Cost 0.00 Surface Treatment Cement, Enclosed sprays/lagg Maintenance (Frequency of) Action Completed Asbestos Type Chrysotile (White) Maintenance (Type of) Review Date

34 ASBESTOS DATA SHEET Created By JR Date 24-Jan-15 Plus AsbestaPLANPlus Asbestos Survey, Management & Risk Analysis Software Unique Sample/Ref No. S013 Company Name LIFE SPACE DEVELPOMENTS LTD Site Photograph/Plan Site Reference Building Ref QSS11506 Site D. Depot Address SITES C & D BOUNDARY WAY WATFORD Level/Floor Felt Roof Construct WD25 7HY Room/Area Roof Description of Location Roof construct Lead Surveyor's Name A R RICHARDSON Name of Testing Laboratory ATHENA Survey Company Name QUBE ENVIRONMENTAL Survey Date 22-Jan-15 Survey Type DEMOLITION SURVEY Estimated Quantity (m2) 50 Asbestos Confirmed Product Description Cement Asbestos Assumed No Asbestos Detected Comments NADIS Occupant Activity NEGATIVE Disturbance (Accessibility) NO ASBESTOS DETECTED IN SAMPLE Disturbance (Extent) Disturbance (Location) Exposure (Usage Time) Material Assessment Score: Priority Assessment Score: TOTAL ASSESSMENT SCORE: Click here for notes on risk assessment and scores Product Type Extent of Damage Surface Treatment Asbestos Type Exposure (Freq of Use) Exposure (No of Occupants) Maintenance (Frequency of) Maintenance (Type of) Proposed Action Estimated Cost 0.00 Action Completed Review Date

35 ASBESTOS DATA SHEET Created By JR Date 24-Jan-15 Plus AsbestaPLANPlus Asbestos Survey, Management & Risk Analysis Software Unique Sample/Ref No. S014 Company Name LIFE SPACE DEVELPOMENTS LTD Site Photograph/Plan Site Reference Building Ref QSS11506 Site D. Depot Address SITES C & D BOUNDARY WAY WATFORD Level/Floor Main Ceiling Construct WD25 7HY Room/Area Workshop Description of Location Product Description Boarding to ceiling to workshop Survey Date 22-Jan-15 Survey Type DEMOLITION SURVEY Estimated Quantity (m2) 36 Comments Cement AIB (Asbestos Insulation Board) HIGH RISK PRODUCT LICENSED MATERIAL POSITIVE: Amosite & Chrysotile. Removal only by Fully Licensed Asbestos removal contractor under controlled conditions Lead Surveyor's Name Name of Testing Laboratory Survey Company Name Occupant Activity Disturbance (Accessibility) Disturbance (Extent) Disturbance (Location) Exposure (Usage Time) A R RICHARDSON ATHENA QUBE ENVIRONMENTAL Asbestos Confirmed Asbestos Assumed No Asbestos Detected Material Assessment Score: 9 Priority Assessment Score: TOTAL ASSESSMENT SCORE: Click here for notes on risk assessment and scores Product Type Boarding, Textiles, Gaskets, P Exposure (Freq of Use) Proposed Action Remove Extent of Damage High Damage Exposure (No of Occupants) Estimated Cost 0.00 Surface Treatment Unsealed board, Encapsulate Maintenance (Frequency of) Action Completed Asbestos Type Amosite (Brown) Maintenance (Type of) Review Date

36 ASBESTOS DATA SHEET Created By JR Date 24-Jan-15 Plus AsbestaPLANPlus Asbestos Survey, Management & Risk Analysis Software Unique Sample/Ref No. S015 Company Name LIFE SPACE DEVELPOMENTS LTD Site Photograph/Plan Site Reference Building Ref QSS11506 Site D. Depot Address SITES C & D BOUNDARY WAY WATFORD Level/Floor Ground floor WD25 7HY Room/Area WC Description of Location Product Description WC Cistern Survey Date 22-Jan-15 Survey Type DEMOLITION SURVEY Estimated Quantity (m2) 1 Comments Composite Positive: Amosite (Brown Asbestos) Composite cisitern Non Licensed Materials Lead Surveyor's Name Name of Testing Laboratory Survey Company Name Occupant Activity Disturbance (Accessibility) Disturbance (Extent) Disturbance (Location) Exposure (Usage Time) A R RICHARDSON ATHENA QUBE ENVIRONMENTAL Asbestos Confirmed Asbestos Assumed No Asbestos Detected Material Assessment Score: 4 Priority Assessment Score: TOTAL ASSESSMENT SCORE: Click here for notes on risk assessment and scores Product Type Asbestos Composites Exposure (Freq of Use) Proposed Action Remove Extent of Damage Low Damage Exposure (No of Occupants) Estimated Cost 0.00 Surface Treatment Composites Maintenance (Frequency of) Action Completed Asbestos Type Amosite (Brown) Maintenance (Type of) Review Date

37 ASBESTOS DATA SHEET Created By JR Date 24-Jan-15 Plus AsbestaPLANPlus Asbestos Survey, Management & Risk Analysis Software Unique Sample/Ref No. S016 Company Name LIFE SPACE DEVELPOMENTS LTD Site Photograph/Plan Site Reference Building Ref QSS11506 Site D. Depot Address SITES C & D BOUNDARY WAY WATFORD Level/Floor Store room and side room WD25 7HY Room/Area Ceiling Lines Description of Location Product Description Boarding to ceiling constructs Survey Date 22-Jan-15 Survey Type DEMOLITION SURVEY Estimated Quantity (m2) 14 Comments Cement AIB (Asbestos Insulation Board) HIGH RISK PRODUCT LICENSED MATERIAL POSITIVE: Amosite & Chrysotile. Removal only by Fully Licensed Asbestos removal contractor under controlled conditions Lead Surveyor's Name Name of Testing Laboratory Survey Company Name Occupant Activity Disturbance (Accessibility) Disturbance (Extent) Disturbance (Location) Exposure (Usage Time) A R RICHARDSON ATHENA QUBE ENVIRONMENTAL Asbestos Confirmed Asbestos Assumed No Asbestos Detected Material Assessment Score: 9 Priority Assessment Score: TOTAL ASSESSMENT SCORE: Click here for notes on risk assessment and scores Product Type Boarding, Textiles, Gaskets, P Exposure (Freq of Use) Proposed Action Remove Extent of Damage High Damage Exposure (No of Occupants) Estimated Cost 0.00 Surface Treatment Unsealed board, Encapsulate Maintenance (Frequency of) Action Completed Asbestos Type Amosite (Brown) Maintenance (Type of) Review Date

38

39

40 P Photo 1. Typical roof line view showing roofing over boarding and felt additional to profile cement roof sheets Photo 2. Profile roof sheet over flashing in bitumen and alloy adhesive and bitumen felt over plywood h Photo 3: Garage 199 in an as found conditon Photo 4. Back to back Garages. Cavity formed by half brick wall to sectional concrete garage walls REF: QSS11506 DATE: 30/01/2015

41 Photo 5. General internal construct P of concrete sectional wall metal door, back to back garages have brick rear wall. Photo 6. General debris on roofs Photo 7: Cavity to wall construct to single garages end units Photo 8. No debris evident within cavity s at points of inspection REF: QSS11506 DATE: 30/01/2015