Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

Size: px
Start display at page:

Download "Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description"

Transcription

1 SECTION DIRECTORY Size and performance summary Glazing performance Grille profiles and patterns Size tables Design Data Detailed Product Description Cross sections The information published in this document is believed to be accurate at the time of publication. However, because we are constantly working to improve our products, specifications are subject to change without notice. Consult your local Pella representative for up-to-date product information. V-RS-1

2 BRAND SUMMARY Vinyl Radius Shape Windows manufactured by Pella Corporation feature an extruded, rigid PVC (polyvinyl chloride) frame and sash with heat-fused mitered corners for a fully welded corner assembly. Fixed windows meet industry standards for water infiltration and wind resistance and meet ENERGY STAR guidelines with Low-E glass. Available colors are White, Almond or Fossil. Vinyl windows and doors are available in all 50 states. Some options listed in this manual will be designated as available only in either the East or West region of the USA. These options are designed to meet the particular market needs of the indicated area of the country. West East Florida Rev. 05/08/2018 V-RS-2

3 BRAND SUMMARY EAST REGION New Construction Design with Nailing Fin Matches Single-Hung and Sliding Window Profiles. WEST REGION New Construction Design with Nailing Fin Matches Single-Hung and Sliding Window Profiles. 2-11/16" Depth 2-11/16" Depth New Construction Design with Nailing Fin and J-Channel Matches Single-Hung and Sliding Window Profiles. 2-11/16" Depth Flush Flange The flush flange frame features a flange designed specifically for easy installation in Florida masonry block construction. The product offering is sized for the specific Florida masonry block sizes. Available in Florida Only 2-11/16" Depth Replacement Design (East Matches Double-Hung Window Profile. 2-11/16" Depth 3-1/4" Depth New Construction Design with Nailing Fin and J-Channel Matches Double-Hung Window Profile. 4-3/16" Depth Rev. 04/27/2018 V-RS-3

4 PRODUCT SELECTION GUIDE Size and Performance Data East and West s East Only 2-11/16" NEW CONSTRUCTION FRAME Flange Standard REPLACEMENT FRAME 4-3/16" NEW CONSTRUCTION FRAME SIZES Standard sizes l l l l Special sizes available built on increments l l l l FRAMES Nail fin for 1-5/8" wall depth l Nail fin with J-Channel for 1-5/8" wall depth l Nail fin with J-Channel for 2-9/16" wall depth l Replacement frame with 3-1/4" frame depth l Flush Flange for 2-5/8" wall depth (Florida l Interior primed wood jamb extensions l l PERFORMANCE 1 Meets or Exceeds AAMA/WDMA Ratings F-R35 R55 F-R25 R 50 F-R25 R 50 F-R25 R 50 Air Infiltration (cfm/ft 2 of 1.57 psf wind pressure) Design Pressure 55 psf psf psf psf Water Penetration Resistance 7.5 psf 7.5 psf 7.5 psf 7.5 psf West Only SIZES Standard sizes Special sizes available built on increments FRAMES Nail fin for 1-1/4" wall depth 2-11/16" NEW CONSTRUCTION FRAME Nail fin for 2" wall depth PERFORMANCE 1 Meets or Exceeds AAMA/WDMA Ratings Air Infiltration (cfm/ft 2 of 1.57 psf wind pressure) Design Pressure Water Penetration Resistance l l l FW-C psf 6.0 psf S = Standard; O = Optional; ( ) = Not Available (1) Published performance data is for single unit only. See Design Data pages later in this section for specific product performance class and grade values. East and West s Rev. 04/27/2018 V-RS-4

5 PRODUCT SELECTION GUIDE Features and Options East and West s GLAZING (3/4" Insulating Glass) Glazing Type 2-11/16" NEW CONSTRUCTION FRAME REPLACEMENT FRAME NEW CONSTRUCTION FRAME Dual-pane insulating glass S S S Insulated Glass Options / Low-E Types Advanced Low-E O O O SunDefense Low-E O O O Clear (no Low-E coating) S S S Additional Glass Options Annealed glass S S S Tempered glass O O O Obscure glass 1 O O O Bronze tinted glass O O O Gas Fill / High Altitude Argon O O O High altitude O O O High altitude with argon O O O INTERIOR / EXTERIOR COLOR White S S S Almond O O O Fossil O O O GRILLES-BETWEEN-THE-GLASS Grille Types 3/4" Contour O O O 1" Contour (East O O O 5/8" Flat O O O Grille Patterns Traditional O O O Perimeter O O O Prairie O O O Sunburst O O O Starburst O O O S = Standard; O = Optional (1) Obscure glass patterns vary based on region. East and West s Rev. 05/08/2018 V-RS-5

6 GLAZING PERFORMANCE - TOTAL UNIT 2-11/16" East Only Glass Thickness Type of Glazing NFRC Certified Product # Glass (mm) Ext. Int. Gap Fill U-Factor Performance Values 1 SHGC VLT CR Shaded Areas Meet ENERGY STAR Performance Criteria in Zones Shown U. S. Canada 2 Zone ER Zone FIXED N NC SC S /4" Clear IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Advanced Low-E IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Advanced Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" NaturalSun Low-E IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" NaturalSun Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" SunDefense Low-E IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" SunDefense Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Bronze Advanced Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Clear IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Advanced Low-E IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Advanced Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" NaturalSun Low-E IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" NaturalSun Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" SunDefense Low-E IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" SunDefense Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Bronze Advanced Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance Climate Zones (1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500. ENERGY STAR values are updated to 2016 (Version 6) criteria. (2) The values shown are based on Canada's updated ENERGY STAR 2015 initiative. For more information, see the ENERGY STAR guidelines. East Only V-RS-6

7 GLAZING PERFORMANCE - TOTAL UNIT 3-1/4" Replacement East Only Glass Thickness Type of Glazing NFRC Certified Product # Glass (mm) Ext. Int. Gap Fill U-Factor Performance Values 1 SHGC VLT CR Shaded Areas Meet ENERGY STAR Performance Criteria in Zones Shown U. S. Canada 2 Zone ER Zone FIXED N NC SC S /4" Clear IG PEL-N air with Grilles-between-the-glass PEL-N /4" Advanced Low-E IG PEL-N air with Grilles-between-the-glass PEL-N /4" Advanced Low-E IG PEL-N argon with Grilles-between-the-glass PEL-N /4" NaturalSun Low-E IG PEL-N air with Grilles-between-the-glass PEL-N /4" NaturalSun Low-E IG PEL-N argon with Grilles-between-the-glass PEL-N /4" SunDefense Low-E IG PEL-N air with Grilles-between-the-glass PEL-N /4" SunDefense Low-E IG PEL-N argon with Grilles-between-the-glass PEL-N /4" Bronze Advanced Low-E IG PEL-N argon with Grilles-between-the-glass PEL-N /4" Clear IG PEL-N air with Grilles-between-the-glass PEL-N /4" Advanced Low-E IG PEL-N air with Grilles-between-the-glass PEL-N /4" Advanced Low-E IG PEL-N argon with Grilles-between-the-glass PEL-N /4" NaturalSun Low-E IG PEL-N air with Grilles-between-the-glass PEL-N /4" NaturalSun Low-E IG PEL-N argon with Grilles-between-the-glass PEL-N /4" SunDefense Low-E IG PEL-N air with Grilles-between-the-glass PEL-N /4" SunDefense Low-E IG PEL-N argon with Grilles-between-the-glass PEL-N /4" Bronze Advanced Low-E IG PEL-N argon with Grilles-between-the-glass PEL-N R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance Climate Zones (1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500. ENERGY STAR values are updated to 2016 (Version 6) criteria. (2) The values shown are based on Canada's updated ENERGY STAR 2015 initiative. For more information, see the ENERGY STAR guidelines. East Only V-RS-7

8 GLAZING PERFORMANCE TOTAL UNIT 4-3/8" East Only Glass Thickness Type of Glazing NFRC Certified Product # Glass (mm) Ext. Int. Gap Fill U-Factor Performance Values 1 SHGC VLT CR Shaded Areas Meet ENERGY STAR Performance Criteria in Zones Shown U. S. Canada 2 Zone ER Zone FIXED N NC SC S /4" Clear IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Advanced Low-E IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Advanced Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" NaturalSun Low-E IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" NaturalSun Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" SunDefense Low-E IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" SunDefense Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Bronze Advanced Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Clear IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Advanced Low-E IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Advanced Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" NaturalSun Low-E IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" NaturalSun Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" SunDefense Low-E IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" SunDefense Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Bronze Advanced Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance Climate Zones (1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500. ENERGY STAR values are updated to 2016 (Version 6) criteria. (2) The values shown are based on Canada's updated ENERGY STAR 2015 initiative. For more information, see the ENERGY STAR guidelines. East Only V-RS-8

9 GLAZING PERFORMANCE TOTAL UNIT Flange Florida Only Glass Thickness Type of Glazing NFRC Certified Product # Glass (mm) Ext. Int. Gap Fill U-Factor Performance Values 1 SHGC VLT CR Shaded Areas Meet ENERGY STAR Performance Criteria in Zones Shown U. S. Canada 2 Zone ER Zone FIXED N NC SC S /4" Clear IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Advanced Low-E IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Advanced Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" NaturalSun Low-E IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" NaturalSun Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" SunDefense Low-E IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" SunDefense Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Bronze Advanced Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Clear IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Advanced Low-E IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Advanced Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" NaturalSun Low-E IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" NaturalSun Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" SunDefense Low-E IG PEL-N air with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" SunDefense Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N /4" Bronze Advanced Low-E IG PEL-N argon with 3/4" Contour Grille PEL-N with 1" Contour Grille PEL-N R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance Climate Zones (1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500. ENERGY STAR values are updated to 2016 (Version 6) criteria. (2) The values shown are based on Canada's updated ENERGY STAR 2015 initiative. For more information, see the ENERGY STAR guidelines. Florida Only V-RS-9

10 GLAZING PERFORMANCE TOTAL UNIT 2-11/16" West Only Glass Thickness Type of Glazing NFRC Certified Product # Glass (mm) Ext. Int. Gap Fill U-Factor Performance Values 1 SHGC VLT CR Shaded Areas Meet ENERGY STAR Performance Criteria in Zones Shown U. S. Canada 2 Zone ER Zone FIXED N NC SC S /4" Clear IG PEL-A air with Grilles-between-the-glass PEL-A /4" Advanced Low-E IG PEL-A air with Grilles-between-the-glass PEL-A /4" Advanced Low-E IG PEL-A argon with Grilles-between-the-glass PEL-A /4" NaturalSun Low-E IG PEL-A air with Grilles-between-the-glass PEL-A /4" NaturalSun Low-E IG PEL-A argon with Grilles-between-the-glass PEL-A /4" SunDefense Low-E IG PEL-A air with Grilles-between-the-glass PEL-A /4" SunDefense Low-E IG PEL-A argon with Grilles-between-the-glass PEL-A /4" Bronze Advanced Low-E IG PEL-A argon with Grilles-between-the-glass PEL-A /4" Clear IG or Obscure/Clear IG PEL-A air with Grilles-between-the-glass PEL-A /4" Advanced Low-E IG PEL-A air with Grilles-between-the-glass PEL-A /4" Advanced Low-E IG PEL-A argon with Grilles-between-the-glass PEL-A /4" NaturalSun Low-E IG PEL-A air with Grilles-between-the-glass PEL-A /4" NaturalSun Low-E IG PEL-A argon with Grilles-between-the-glass PEL-A /4" SunDefense Low-E IG PEL-A air with Grilles-between-the-glass PEL-A /4" SunDefense Low-E IG PEL-A argon with Grilles-between-the-glass PEL-A /4" Bronze Advanced Low-E IG PEL-A argon with Grilles-between-the-glass PEL-A R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance Climate Zones (1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500. ENERGY STAR values are updated to 2016 (Version 6) criteria. (2) The values shown are based on Canada's updated ENERGY STAR 2015 initiative. For more information, see the ENERGY STAR guidelines. West Only V-RS-10

11 ThermaStar by Pella GRILLE T YPES East and West s Grille Profiles 5/8" Flat Grille 3/4" Contour Grille 1" Contour Grille (WEST REGION ONLY) (EAST AND WEST REGION) ( E AST R E GI O N O N LY ) Grille Patterns COLON IA L SU NB U RST STAR B U R ST P R AIR I E P E R IM E T E R Half Circle Type 1 Quarter Circle Type 2 (L) and (R) Available Springline Type 3 Chord Type 6 ) Arch Head Type 12 Partial Arch Head Types 14 (L) and 13 (R) Available Full Circle Type 16 V-RS-11

12 SPECIAL SIZE FRAME DIMENSIONS Parameters and Product Rules East and West s SHAPES FRAME WIDTH (INCHES) FRAME HEIGHT (INCHES) MINIMUM MAXIMUM MINIMUM MAXIMUM 29-1/2" 95-1/2" 14-1/2 " 47-1/2" Half Circle Half circles are built for a true half circle rough opening (1/4" offset from actual frame) FH = (FW/2) - 1/4" 23-1/2 " 73-1/2" 23-1/2" 73-1/2" Quarter Circle N/A 29-1/2" 95-1/2" 20-1/2 " 108" Springline Minimum SH is 8" 29-1/2" 11-1/2" Full Chord FW 59-1/2"; Minimum FH = 11-1/2" FW > 59" and 71-1/2"; Minimum FH = 12-3/8" FW >71-1/2" and 95-1/2"; Minimum FH = 16-15/16" Maximum FH < (FW/2) - 1/4" 17-1/2 " 95-1/2" 17-1/2" 108" Arch Head Width and height ratio can not exceed 8:1 if LS is 95-1/2" If LS is > 95-1/2", width and height ratio must be < 5:1 Minimum leg length is 8" Minimum corner angle is 40 Minimum cut angle 20 Maximum frame angle is 160 SH must be > (FH - (Width / 2) + 1-3/8" Minimum Radius: 14-3/4" Maximum Radius: 239-3/4" Radius = FH - SH 17-1/2 " 95-1/2" 17-1/2" 108" Partial Arch Head Width and height ratio can not exceed 8:1 if LS is 95-1/2" If LS is > 95-1/2", width and height ratio must be < 5:1 Radius must be > (FH - SH) + 3 Minimum leg length: 8" Minimum corner angle: 40 Minimum cut angle: 20 Maximum frame angle: 160 Minimum Radius: 14-3/4" Maximum Radius: 239-3/4" 29-1/2 " 73-1/2" 29-1/2" 73-1/2" Full Circle Tempered glass is required for any units where glass dimensions exceed 48" Miscellaneous Formulas VISIBLE GLASS ACTUAL GLASS Width = 3-15/16" Height = 3-15/16" Width = 2-13/16" Height = 2-13/16" To convert areas to square meters (m 2 ), multiply square feet by FRAME HEIGHT FRAME WIDTH For all shapes, calculate the area as if it were a rectangle. KEY: FH = Height FR = Rise FW = Width LS = Long Side SH = Short Side Height SSH = Straight Side Height Units are available in increments. All dimensions are referenced to the outside of the frame excluding nail fin or any installation accessories. General Rules: Both width and height can not be > than 73-1/2" Maximum Square Foot (of Rectangle framing shape): 40 ft 2 Bronze glass - limited to 22 ft 2 East and West s V-RS-12

13 SIZE TABLES Sunburst Grilles East Half Circle Half Circles (813) (800) 2' 8" 311/2" (914) (902) 3' 0" 35 1/2" (965) (953) 3' 2" 37 1/2" (1 016) (1 003) 3' 4" 39 1/2" (406) (394) 1' 4" 15 1/2 " 2-8/1-4 (457) (445) 1' 6" 17 1/2 " 3-0/1-6 (457) (445) 1' 7" 18 1/2 " 3-2/1-7 (508) (495) 1' /2" 3-4/1-8 (1 524) (1 511) 5' 0" 59 1/2" (1 829) (1 816) 6' 0" 71 1/2" (762) (749) 2' 6" 1/2" /2-6 (914) (902) 3' 0" 1/2" /3-0 Quarter Circle Quarter Circles (610) (597) 2' 0" 23 1/2" (610) (597) 2' 0" 23 1/2" (711) (699) 2' 4" 27 1/2" (711) (699) 2' 4" 27 1/2" (813) (800) 2' 8" 311/2" (813) (800) 2' 8" 311/2" (610) (597) 1/2" 2-0/ /2-0 (711) (699) 2-4/ / / /2-8 (914) (902) 3' 0" 35 1/2" (965) (953) 3' 2" 37 1/2" (965) (953) 3' 2" 37 1/2" (1 016) (1 003) 3' 4" 39 1/2" (965) (953) 3' 2" 37 1/2 " 2' 4" 1/2" 27 (813) (800) 1/2" 2' 8" 31 (914) (902) 3' 0" 35 1/2" (1 016) (1 003) 3' 4" 39 (1 016) (1 003) 3' 4" 39 1/2 " 1/2" (914) (902) 3' 0" 35 1/2 " 2' 0" / / / / / /3-4 Not to scale. East Only V-RS-13

14 Half Circles Call Size Masonry Buck Tip to Tip Call Size Masonry Buck Tip to Tip Call Size Masonry Buck Tip to Tip FL-2 " 7 8 " FL-3 1 / 4 " 1/2" 1 / 4 " 1 / 4 " FL-D2 Quarter Circles Call Size Masonry Buck Tip to Tip " 7/ 8 3/8" Call Size Masonry Buck Tip to Tip /4" 1/ 4" 36" 37" FL-1 FL-1 FL-2 FL-2 Call Size Masonry Buck Tip to Tip Call Size Masonry Buck Tip to Tip /8" 4 74" 73 73" 74" 1 / 4 " / / ThermaStar by Pella SIZE TABLES 2-11/16" Flange - Sunburst Grilles Florida Only Half Circle " 37" 3/4" 1/ 4" " 7/ 8 3/8" D2 3/8" 1/ 4" 73" 74" 2 3/4" 18 18" 3/4" 3/4" " 7 / /8 " /8" / 4 " 2 37" 36 36" 37" " 7/ 8 3/8" D2 74 3/8" 73 1/ 4" 73" 74" FL-3 FL-3 FL-D2 FL-D2 Not to scale. Sunburst grille pattern shown. Florida Only V-RS-14

15 DESIGN DATA 2-11/16" East and West s East HALF CIRCLE QUARTER CIRCLE Unit Width Height Performance Class & Grade Unit Width Height Performance Class & Grade 2-8/ /2 15-1/2 R50 3-0/ /2 17-1/2 R50 3-4/ /2 19-1/2 R50 4-0/ /2 23-1/2 R50 5-0/ /2 29-1/2 R50 6-0/ /2 35-1/2 R25 2-0/ /2 23-1/2 R50 2-4/ /2 27-1/2 R50 2-8/ /2 31-1/2 R50 3-0/ /2 35-1/2 R50 3-4/ /2 39-1/2 R50 East Only West HALF CIRCLE QUARTER CIRCLE Unit Width Height Performance Class & Grade Unit Width Height Performance Class & Grade 2-6/ /2 14-1/2 C30 3-0/ /2 17-1/2 C30 3-6/ /2 20-1/2 C30 4-0/ /2 23-1/2 C30 5-0/ /2 29-1/2 C30 6-0/ /2 35-1/2 C30 2-0/ /2 23-1/2 C30 2-6/ /2 29-1/2 C30 3-0/ /2 35-1/2 C30 3-6/ /2 41-1/2 C30 4-0/ /2 47-1/2 C30 West Only Florida 2-11/16" Flush Flange CIRCLEHEAD UNITS: HALF CIRCLE CIRCLEHEAD UNITS: QUARTER CIRCLE Unit Width Height Performance Class & Grade Unit Width Height Performance Class & Grade FL /4 F-R55 FL /8 F-R55 FL-D /4 F-R55 FL /8 18-1/8 F-R55 FL F-R55 FL /8 52-1/2 F-R55 FL-D F-R55 Florida Only To convert areas to square meters (m 2 ), multiply square feet by V-RS-15

16 DETAILED PRODUCT DESCRIPTIONS East and West s ThermaStar by Pella FRAME Overall frame depth: [2-11/16" [new construction frame with integral nailing fin [and J-channel (East region only)] [integral flush flange (Florida region only)]]; [3-1/4" replacement frame (East region only)]; [4-3/16" new construction frame with integral nailing fin and J-channel (East region only)]. members are extruded rigid PVC. members are mitered and heat-fused to provide a fully welded corner assembly. GLAZING SYSTEM Quality float glass complying with ASTM C Exterior face-glazed 3/4" sealed insulating glass. [Clear] [Advanced Low-E coated [with argon]] [SunDefense Low-E coated, [with argon]] [NaturalSun Low-E [with argon]] [Bronze, advanced Low-E coated, [with argon]]; [Clear] [NaturalSun Low-E] [Obscure] [Tempered] [Standard Obscure [rain] region only)] [High altitude [with argon] region only)]. INTERIOR / EXTERIOR All window frame members have an integral color extruded throughout the profiles. All exposed PVC surfaces are smooth, glossy and uniform in appearance. Colors are [White] [Almond] [Fossil]. OPTIONAL PRODUCTS Grilles Grilles-Between-the-Glass Insulating glass contains [3/4" contoured (East or West)] [1" contoured (East)] [5/8" flat )] aluminum grilles permanently installed between two panes of glass. Grilles match color of interior and exterior frame. Factory applied primed wood jamb extension for [4-9/16"] [6-9/16"] wall depth, for 2-11/16" new construction frame East region. Rev. 05/08/2018 V-RS-16

17 UNIT SECTIONS East and West s EAST REGION - NEW CONSTRUCTION FRAME Standard Nail Fin WEST REGION - NEW CONSTRUCTION FRAME Standard Nail Fin [19] 4" OAW [101] 1 1/4" [33] 3 3/8" OAW [86] 1 15/16" [49] 15/16" [23] 15/16" [23] 1 3/16" [30] 1/2" [13] [35] 3/4" [19] 1 3/16" [30] 1 5/16" [33] 4 3/16" OAW [107] 7/8" [22] [35] 1 [29] 1 1/2" [38] 1 5/16" [33] 1 1/2" [38] 3 3/8" OAW [86] 1 5/16" [33] 3 1/4" OAW [83] 15/16" [23] 1 3/16" [30] 15/16" [23] 1 5/16" [33] 1 [29] 1 [29] Standard Nail Fin with J-Channel WEST REGION - REPLACEMENT FRAME Standard Block 3/4" [19] 3/4 [19] 1 5/8" [41] Flush Flange - Florida Only 5/8" [16] 2 5/8" [67] EAST REGION - REPLACEMENT FRAME Standard Block Scale 3" = 1' 0" All dimensions are approximate. Rev. 04/27/2018 East and West s V-RS-17

18 UNIT SECTIONS New Construction East EAST 2 11/16" 15/16" [23] FRAME HEIGHT [34] HEAD FIXED SILL 1 [29] 1 [29] [34] STANDARD NAIL FIN 5/8" [16] 3" [76] JAMB FRAME WIDTH 5" [126] 1 [29] 4" [101] 4 9/16" [116] 6 9/16" [167] 4 9/16" Wall 6 9/16" Wall Optional Factory Applied Wood Jamb Extensions (Curved Shown Above, Straight Shown Below) 5/8" [16] 1 3/16" [30] FRAME HEIGHT 2" [51] HEAD FIXED SILL 4" [101] [19] [35] 2" [51] 1 5/16" [34] JAMB STANDARD NAIL FIN 4 3/16" OAW 2" [51] 4 9/16" Wall 4" [102] 6 9/16" Wall 5/8" [16] FRAME WIDTH Optional Factory Applied Wood Jamb Extensions (Curved Shown Above, Straight Shown Below) 3 3/8" Scale 3" = 1' 0" All dimensions are approximate. V-RS-18

19 UNIT SECTIONS Fin with J-Channel East EAST 2 11/16" 1 5/8" [41] 15/16" [23] NAIL FIN J-CHANNEL FRAME HEIGHT [34] HEAD FIXED SILL 5/8" [16] 3/4 [19] 9/16" [14] 3/4" [19] [34] JAMB FRAME WIDTH 3" [76] 5" [126] 4 9/16" 6 9/16" 1 [29] 4 3/16" [107] 4 9/16" [116] 6 9/16" [167] Optional Factory Applied Wood Jamb Extensions (Curved Shown Above, Straight Shown Below) 5/8" [16] [35] 1 3/16" [30] FRAME HEIGHT 2" [51] HEAD FIXED SILL 4 3/16" [107] 3/4" [19] 13/16" [19] 1/2" [13] 2" [51] 1 5/16" [34] NAIL FIN J-CHANNEL 4 3/16" OAW 2" [51] 4 9/16" 4" [102] 6 9/16" 5/8" [16] JAMB FRAME WIDTH Optional Factory Applied Wood Jamb Extensions (Curved Shown Above, Straight Shown Below) Scale 3" = 1' 0" All dimensions are approximate. East Only V-RS-19

20 UNIT SECTIONS New Construction West WEST 2 11/16" 1 5/16" [33] FRAME HEIGHT 1 1/4" [33] 2 1/4" [58] 1 7/16" [36] 1 [29] 1 1/2" [38] 2 1/4" [58] STANDARD NAIL FIN 7/8" [22] 1 1/2" [38] HEAD FIXED SILL 1 5/16" [33] JAMB FRAME WIDTH 1 7/16" [36] 1 1/4" [33] Scale 3" = 1' 0" All dimensions are approximate. Rev. 04/27/2018 East Only V-RS-20

21 UNIT SECTIONS Flush Flange Florida Only EAST 2 11/16" FRAME HEIGHT [34] HEAD FIXED SILL 2 5/8" [67] 15/16" [23] [34] 5/8" FLUSH FLANGE 5/8" [16] JAMB 15/16" [23] FRAME WIDTH Scale 6" = 1' 0" All dimensions are approximate. Florida Only V-RS-21

22 UNIT SECTIONS Replacement East EAST 2 11/16" 15/16" [23] STANDARD BLOCK FRAME FRAME HEIGHT [34] HEAD FIXED SILL 2 11/16" [34] JAMB FRAME WIDTH 15/16" [23] 3 1/4" [83] 1 3/16" [30] FRAME HEIGHT 1 7/8" [47] HEAD FIXED SILL 2 11/16" 1 7/8" [47] STANDARD BLOCK FRAME 3 1/4" OAW 1 3/16" [30] JAMB FRAME WIDTH Scale 6" = 1' 0" All dimensions are approximate. East Only Rev. 04/27/2018 V-RS-22

23 UNIT SECTIONS Replacement West WEST 2 11/16" 1 5/16" [33] STANDARD NAIL FIN FRAME HEIGHT 1 1/2" [38] 7/8" [22] 2 1/4" [58] 1 5/16" [33] HEAD FIXED SILL 2 11/16" 1 1/2" [38] 2 1/4" [58] JAMB FRAME WIDTH Scale 6" = 1' 0" All dimensions are approximate. East Only Rev. 04/27/2018 V-RS-23