PLATINUM AVENUE PROPERTIES HOME INSPECTIONS (702)

Size: px
Start display at page:

Download "PLATINUM AVENUE PROPERTIES HOME INSPECTIONS (702)"

Transcription

1 Inspection No.: Inspector: Fred Roach Inspection Date: 4/8/15 Client: John & Jane Doe Address: 123 W Elm Street, Las Vegas, NV This report is fictitious. The images and issues noted are from multiple properties. The photos added at the end of the report are all from one property and do not include all of the notations from earlier in the report. It is just a sample of some issues we ve seen. It is designed to show potential clients and their agents the depth of our inspections. *** General Notes *** We attempt to give the client a comprehensive, clear-cut, unbiased view of the home. The purpose of this inspection is to identify 'MAJOR' problems associated with the property being purchased or sold. Minor items will also be mentioned as minor issues can develop into serious problems. Areas that may be of concern to us may not be of concern to the client and some items that may be of concern to the client may be considered minor to us. Therefore, it is advisable to read the entire report. Where repairs or replacements are suggested, we recommend licensed professionals in that particular field be called upon to make those repairs. We do not perform verification of repairs, therefore, we advise the client to obtain all paperwork from these professionals who will be happy to provide written statements concerning their work. We further recommend maintaining all paperwork on repairs for future reference. Mold / mildew / asbestos / Chinese drywall / Kitec, galvanic, yellow brass and Polybutylene plumbing testing or inspecting are beyond the scope of this inspection. Page 1

2 Stains noted at the cabinet base at the dishwasher area. Suggest further review by a licensed contractor. Multiple stucco cracks noted at exterior walls. Recommend review by a licensed contractor. Page 2

3 Multiple settling cracks noted on ceiling. Recommend review by a licensed contractor. Page 3

4 Air conditioner breaker is 50 amps: AC unit shows max breaker should be 35 amps. Recommend the installation of the proper breaker by a licensed electrical contractor for safety. Page 4

5 Duct tape was used to seal the HVAC ducts. Recommend proper metal HVAC tape to seal the system correctly to avoid leaks. Pet door installed on the Garage Fire Door negating the fire rating. Recommend installation of a new fire rated door per code for safety. Page 5

6 Recommend installation of strapping on water heater for safety. Page 6

7 Cracked truss noted in attic. Recommend review and repairs by a licensed contractor. GFCI at pool failed to trip. Recommend repairs by a licensed electrician for safety. Page 7

8 Leak noted at left sink in Master Bathroom. Recommend repairs by a licensed plumber. Multiple slipped tiles noted on roof. Recommend repairs by a licensed roofing contractor. Page 8

9 Rusted sink noted in guest bathroom. Recommend replacement by a licensed plumber. Sink disposal rusted. Recommend replacement. Page 9

10 Single nut holding HVAC unit noted on each bracket. Recommend double nuts and epoxy to hold the unit for safety. Page 10

11 Rubber water hoses noted at washing machine. Recommend steel braided hoses. Corrosion at angle stop under sink. Recommend review and repairs by a licensed plumber. Page 11

12 Pool level uneven at east and west ends. This is a formed one piece fiberglass pool. The above ground area is level suggesting the pool is not sinking but was installed improperly. Suggest review of all pool systems by a licensed pool contractor. Page 12

13 Cracks noted in multiple sinks in Master and Guest Bathrooms. Recommend review and repairs by a licensed plumber. Trip hazard noted at front door walkway. Recommend installation of a hand rail from entry way, around the corner of the steps, to the driveway for safety. Page 13

14 Rust noted in HVAC pan and discoloration noted at secondary condensation discharge line. Suggest review and repairs by a licensed HVAC contractor. Page 14

15 Page 15

16 Definition of Terms: SERVICEABLE: The item is performing its function; its condition is appropriate for its age and use. NOTED: A condition or issue has been observed requiring further explanation. It does not necessarily represent an improper condition or need for repair. General Conditions: 1 Inspector Fred Roach 2 Structure Type Single Family Home 3 Levels Two Story Structure 4 Lot Type Flat lot front door and garage face west 5 Estimated Age Approximately 12 years old 6 Estimated Size Approximately 3,034 square feet 7 Weather 57 degrees, sunny Conditions 8 Occupant Status Occupied 9 Attendees Buyer s agent Buyer 10 Start time 8:35 AM 11 End time 11:45 AM Page 16

17 Exterior: PLATINUM AVENUE PROPERTIES HOME INSPECTIONS Our exterior evaluation is visual only. Our review does not take into consideration normal wear, cosmetic issues, code or manufacturer's specifications. Step Components Comments 101 Driveway Concrete - Common cracks noted 102 Walkways Concrete - Common cracks noted 103 Fences / Gates Iron Gates - Block Wall 104 Exterior Siding Stucco Common cracks noted - Stucco is a masonry surface material put on in layers over an expanded wire mesh that is fastened to the substrate. 105 Trim Serviceable: 106 Windows & Frames Satisfactory - The siding is in serviceable condition. Typical expansion cracks are apparent around doors and windows, or other wall openings. This is considered normal, and is attributed to normal expansion and contraction of the construction materials due to temperature and humidity changes, or shrinkages in the lumber as it dries in the desert sun over the years. No action is required, unless cosmetic repairs are wanted. Double-glazed insulated windows noted. Failed seals noted on multiple windows. Conditions such as temperature, humidity and lighting limit the ability of the inspector to review these windows for broken seals. For more information on the condition of these windows, consult the seller prior to closing. 107 Electrical Fixtures Serviceable GFCI serviceable 108 Gutters & None Downspouts 109 Hose bibs Serviceable pressure tested 110 Sprinkler System A timing device controls the sprinkler. Timing devices are beyond the scope of this inspection. Suggest client verify performance with seller prior to closing. 111 Bell / Chime Serviceable 112 Exterior Doors Serviceable 113 Chimney Serviceable 114 Lot/Grade Drainage Flat lot Lot is sloped improperly that may fail to drain moisture from the structure. Recommend re-grading by a licensed landscaper. Page 17

18 A swale is a low tract of land designed to manage water runoff and increase rainwater infiltration. 115 Gas Meter Located at west side 116 Exposed Foundation All slabs experience a certain amount of cracking due to shrinkage in the process of drying. Common cracks are normal for most concrete foundations. Newly noticed cracks should be monitored. Floor coverings prevent detection of settlement in all but the most severe cases. Our inspection is limited to a visual inspection. It is beyond the scope of our inspection to open up carpet or flooring to look underneath for foundation problems. 117 Water Meter No leaks noted at the water meter. Page 18

19 Patio: PLATINUM AVENUE PROPERTIES HOME INSPECTIONS We suggest periodically checking concrete, wood and other materials for signs of deterioration. We recommend periodically treating all wood and monitoring drainage around concrete slabs to help prevent deterioration. Step Components Comments 201 Cover Serviceable Aluminum + Vinyl 202 Enclosure None 203 Electrical Serviceable lighting & outlets 204 Windows/Screens None 205 Deck/Slab Concrete: common cracks noted 206 Stairs/Stoops None 207 Railing None 208 Patio Comments No additional comments Page 19

20 Roof: Our evaluation of the roof is to determine if portions are missing or deteriorating. Portions of underlayment and decking are hidden from view and cannot be evaluated by our visual inspection. Leaks are not always visible to the inspector nor can the inspector determine the watertight integrity of a roof by visual inspection. If such a review is desired, client should contact a qualified licensed roofing contractor. Concrete tile roofs are among the most expensive and durable of all roofs, and are warranted by the manufacturer to last for forty years or more, but are usually only guaranteed against leaks by the installer from three to five years. Like other pitched roofs, they are not designed to be waterproof, only water resistant, and are dependent on the integrity of the waterproof membrane beneath them, which cannot be seen without removing the tiles, but which can be split by movement, deteriorated through time, or by ultra-violet contamination. Significantly, although there is some leeway in installation specifications, the type and quality of membranes that are installed can vary from one installer to another, and leaks do occur. The majority of leaks result when a roof has not been well maintained or kept clean thus we recommend servicing them annually. Step Components 301 Roofing Type and Materials Comments Sloped roof, concrete tile: observed from ground with binoculars multiple slipped tiles noted. Recommend repairs by a licensed roofing contractor. 302 Number of layers One 303 Flashing Serviceable 304 Conditions This is a visual inspection only. No certification, warranty or guarantee is given as to the watertight integrity of the roof. Inspectors cannot determine the watertight integrity of roofs by a visual inspection nor can they predict future leaks or if the roof was installed according to the manufacturer's specifications. If such an inspection or certification of the roof is desired, the client should contact a qualified licensed roofer prior to closing. 305 Skylights None 306 Roof Penetrations Serviceable 307 Roof Comments The review was limited to do limited visibility due to close housing. A more thorough inspection can be completed by a licensed roofing contractor prior to closing. The inspector does not walk tile roofs as this could damage the tiles. Page 20

21 Attic: Water stains around roof penetrations such as chimneys, plumbing, vents, and heating vents are very common. Although it is difficult, every effort is made to determine if stains are active. Insulation in the attic is one of the best ways to improve the energy efficiency of a home. Our report measures insulation materials by thickness. Generally, the greater the thickness of the insulation, the greater the resistance is to heat loss. Truss Uplift Many homes today have been built with trusses which are prefabricated structural assemblies that hold up the roof and the top floor ceilings. Trusses are a series of triangles fastened together with gusset plates. The outside members of a truss are called chords while the inner pieces are known as webs. Truss uplift occurs when the top chord of the truss expands while the bottom chord contracts due to changes in humidity. Truss uplift usually becomes visible in a home during the winter when the bottom chords (the ceiling joist part of the truss), which are buried under ceiling insulation, stay warm and dry but the top chords are exposed to moisture. The resulting stress causes the truss to lift up at its center. When this happens, a crack can appear at the wall and or ceiling juncture. From a structural standpoint, truss uplift isn t a problem, but cosmetically, it can cause cracks and separations in the drywall. Many homeowners try to repair the cracks with drywall compound, only to have them reappear next year. Contractors can mask truss uplift by securing the ceiling drywall to the top of the interior walls and not the trusses for 18 inches away from the interior walls. As the drywall flexes, it stays fastened to the walls while the trusses lift above it. Decorative molding can also be installed where the walls meet the ceilings. The molding should be fastened to the ceilings, not to the walls so as the ceiling move up, so does the molding thereby hiding the gap. Page 21

22 Attic cont.: PLATINUM AVENUE PROPERTIES HOME INSPECTIONS Step Components Comments 401 Access We make every effort to fully inspect the entire attic including the trusses and all other systems within. Entering attics that are heavily insulated can cause damage to the insulation and attic framing. Attics with deep insulation cannot be safely entered due to limited visibility of the framing members upon which the inspector must walk. In such cases, the attic is only partially accessible which limits the review of the attic to the view from the hatch area only. 402 Framing Trusses Cracked truss noted. Recommend repairs by a licensed roofing contractor. 403 Sheathing Wafer-board 404 Ventilation Eave vents 405 Electrical Serviceable 406 HVAC Ducting Serviceable Duct tape noted recommend correct metal HVAC tape 407 Insulation Rolled in, blown in, 12 to Duct Support / Strapping Serviceable Not visible 409 Attic Comments No additional comments Page 22

23 Garage: PLATINUM AVENUE PROPERTIES HOME INSPECTIONS Attached garages should be separated from common walls of the house by a proper firewall and fire door. This is to keep the migration of any smoke or fire from entering the house in the event of a fire in the garage. A self closer on the fire door between the garage and the house is an additional safety precaution. It is recommended all garage doors be equipped with a safety reverse device to reverse the direction of the door if it should meet any resistance on the way down. This is important when children may be present. Some older homes may not have these safety reverse devices as they may not have been required when the home was built. If so, the buyer may wish to consider an upgrade. Step Components Comments 501 Location Attached 502 Exterior See comment Roof See comment Garage Roof See comment 302 Flashing 505 Garage Roof See comment 304 Conditions 506 Floor / Slab Concrete Common cracks noted 507 Garage Door Serviceable roll up metal panel 508 Garage Door Serviceable Hardware 509 Garage Door Opener This garage door is equipped with a safety reverse device, which operated properly when tested at the time of the inspection. The U.S. Product Safety Commission recommends that these devices be checked monthly for proper operation and safety 510 Windows / None Screens 511 Fire Door Pet door added. Recommend a new fire door installed for safety. 512 Service Door None 513 Fire Wall / Ceiling Serviceable 514 Garage Framing & Supports 515 Walls Serviceable 516 Ceiling Serviceable 517 Electrical Ground Fault Circuit Interrupter serviceable 518 Garage Comments This is a finished garage, therefore framing and supports were not visible. No additional comments Page 23

24 Laundry Area: Step Components Comments 601 Floor Tile 602 Walls Serviceable 603 Ceiling Serviceable 604 Doors Serviceable 605 Windows/Screens None 606 Cabinets Serviceable 607 Laundry Sink/Tub Serviceable 608 Cross None Connections 609 Electrical Serviceable 610 Exhaust Fan Serviceable 611 Washer Hook-ups Rubber Recommend the installation of steel braided hoses 612 Dryer Hook-ups Gas 613 Laundry Area Comments Recommend drain pan installation under washer. Page 24

25 Heating & Air Conditioning: Our evaluation of major systems is visual and functional provided power and/or fuel is supplied to the components. Items not listed here as well as things we cannot see, such as utilities, drains, and ducts inside walls, floors and underground are beyond the scope of this inspection. DISMANTLING AND/OR EXTENSIVE INSPECTION OF INTERNAL COMPONENTS OF ANY APPLIANCE, INCLUDING HEATERS, HEAT EXCHANGERS AND AIR CONDITIONERS IS BEYOND THE SCOPE OF THIS REPORT. THE LOCAL UTILITY COMPANY MAY CONDUCT SUCH AN INSPECTION UPON REQUEST. Our inspection is not a heat engineering or sufficiency review. We suggest the client ask the sellers/occupants if any areas of the home do not properly heat or cool. We also suggest the client obtain the maintenance history of the furnace as well as receipts for any repairs for which a warranty might apply. Clients are encouraged to purchase a home warranty plan since furnaces can require repair or replacement at any time. Modern furnaces are complicated appliances and should be treated with care. Regular cleaning or replacement of any and all filters within the HVAC system is vital to the health of the furnace and can improve the efficiency of attached central air conditioning. Step Components Comments 901 Heating Gas The furnace was tested using normal operating controls and appeared to function properly at time of the inspection. Due to inaccessibility of many of the components of this unit, the review is limited. Holes or cracks in the heat exchanger are not within the scope of this inspection as heat exchangers are not visible or accessible to the inspector. The unit was operated by the thermostat. 902 Conditions Recommend servicing/cleaning the filters on a regular basis to ensure proper operation and airflow. 903 Exhaust Venting Serviceable 904 Thermostat Honeywell 905 Ducts/Registers Efficiency and load calculations are beyond the scope of this inspection and expressly omitted from this report. If a detailed inspection is desired, a licensed heating contractor should be consulted prior to closing to ensure proper operation of the units. 906 Air Conditioning System Gas, one unit, Unit calls for 35-amp breaker at the main electrical panel breaker box, 50-amp breaker noted. Recommend the installation of a 35 amp breaker by a licensed electrician. 907 A/C Condition The air conditioner was activated to check the operation of Page 25

26 the motor and the compressor, both of which appear to be in serviceable condition at the time of the inspection. A detailed review of the cooling capacity of this unit is beyond the scope of this inspection. Temperature differential was within the 15 to 20 degrees of normal operating range at time of inspection. Page 26

27 Plumbing: PLATINUM AVENUE PROPERTIES HOME INSPECTIONS Step Components 1001 Plumbing Supply System Comments Per MLS/agent property has a public water supply Plumbing Waste Per MLS/agent property has a public waste system. System 1003 Supply Pipes Not visible 1004 Waste Pipes Not visible 1005 Piping Insulation Not visible 1006 Pipe Strapping Not visible 1007 Water Heater Gas, 50 Gallons, Temperature pressure relief valve with drain line installed as a safety feature. Unit has a cold water shut off valve. Recommend installation of earthquake straps for safety Exhaust Venting Serviceable System 1009 Cross None Connections 1010 Plumbing The water meter was examined at the beginning and the end System of the inspection with no movement observed. Movement can Comments indicate possible leaks in the system or its components including toilets, sinks, icemakers, irrigation system valves, etc. Many sections of the pipes are not visible and the inspector cannot dismantle walls or flooring to check the entire system. If the client warrants a more detailed view of the plumbing system, we suggest further review by a qualified licensed plumber prior to closing. Page 27

28 Electrical System: Our electrical inspection meets the ASHI standards of practice and is done by sampling visibly accessible wiring and fixtures. Determining the actual capacity of the system requires load calculations which are not within the scope of this report. Underground circuits and concealed components of the system are not inspected. While age is one factor, many homes have electrical issues created by amateur electricians. We do not move belongings and do not examine every fixture, outlet, wiring run, etc., nor do we remove insulation or wall coverings. Covers are not removed, with the exception of the cover of the main electrical panel, when this can be done safely and without risking damage to the finish. Much of the wiring in the home is not visible and not reviewed. Once the current occupant's belongings have been removed, it's a good idea to check all outlets with a tester and to look inside cabinets, closets and other obstructed areas before moving in your own belongings. We use a standard electrical tester to check a sample of outlets. While the tester is generally reliable, it can be fooled by certain improper wiring practices which we cannot detect during a general home inspection. Because electrical defects are safety concerns, we advise the use of a qualified licensed electrician for cost estimates, repairs and upgrades, prior to close. Step Components 1101 Main Electrical Panel Comments The main electrical service is approximately 200 amps. The main disconnects were noted. The breakers are present to provide overload protection. The service entrance is underground. The system appears to be properly grounded. None 1102 Sub Panels /Location 1103 Smoke Detectors The smoke detectors that could be reached without a ladder tested serviceable but were not tested with smoke. Suggest testing all detectors on a monthly basis Electrical System Comments No additional comments Page 28

29 Kitchen: PLATINUM AVENUE PROPERTIES HOME INSPECTIONS The kitchen inspection is a combination of visual and operational testing. If necessary utilities are connected and operations, appliances are operated using normal operating controls. Calibrations to cooking systems or their efficiencies are not evaluated nor are life expectancies given. NOTE: Dishwashers can fail at any time due to their complexity. Our inspection is to determine if the system is free of leaks and excessive corrosion. Step Components Comments 1301 Floor Tile 1302 Walls Serviceable 1303 Ceiling Serviceable 1304 Doors Serviceable 1305 Windows / Serviceable Screens 1306 Cabinets Serviceable 1307 Counter Tops Serviceable 1308 Electrical Serviceable Ground fault interrupter noted 1309 Sinks Serviceable 1310 Faucets Serviceable 1311 Traps/Drain Serviceable System 1312 Disposal Rusted unit noted. Recommend replacement 1313 Dishwasher Serviceable 1314 Stove/Cook Top Gas 1315 Oven Gas 1316 Hood/Fan/Light Serviceable 1317 Microwave Serviceable 1318 Heat Source Serviceable 1319 Kitchen No additional comments Comments Page 29

30 Dining Room: Step Components Comments 1401 Floor Carpet 1402 Walls Serviceable 1403 Ceiling Serviceable 1404 Doors Serviceable 1405 Windows/Screens Serviceable 1406 Electrical Serviceable 1407 Heat Source Serviceable 1408 Fireplace None Living Room: Step Components Comments 1501 Floors Wood 1502 Walls Serviceable 1503 Ceiling Serviceable 1504 Doors Serviceable 1505 Windows/Screens Serviceable 1506 Electrical Serviceable 1507 Heat Source Serviceable 1508 Fireplace None Family Room: Step Components Comments 1601 Floors Carpet 1602 Walls Serviceable 1603 Ceiling Serviceable 1604 Doors Serviceable 1605 Windows/Screens Serviceable 1606 Electrical Serviceable 1607 Wet Bar None 1608 Heat Source Serviceable 1609 Fireplace None Page 30

31 Entry Step Components Comments 1701 Floor Tile 1702 Walls Serviceable 1703 Ceiling Serviceable 1704 Doors Serviceable 1705 Windows/Screens Serviceable 1706 Electrical Serviceable 1707 Entry Comments No additional comments Halls & Stairs Step Components Comments 2301 Location Hallway / Stairs 2302 Floor Carpet 2303 Walls Serviceable 2304 Ceiling Serviceable 2305 Doors Serviceable 2306 Windows/Screens Serviceable 2307 Electrical Serviceable 2308 Stairs Serviceable 2309 Railing Serviceable Page 31

32 Bathroom PLATINUM AVENUE PROPERTIES HOME INSPECTIONS Our focus in bathrooms is directed at identifying visible water damage and/or visible plumbing problems. Cosmetic issues such as common rust, common corrosion and/or stains may not always be reported. Step Components Comments 1901 Location Master Bathroom 1902 Floor Tile 1903 Walls Serviceable 1904 Ceiling Serviceable 1905 Doors Serviceable 1906 Windows/Screens Serviceable 1907 Electrical Serviceable Ground Fault Interrupter noted 1908 Exhaust Fan Serviceable 1909 Heat Source Serviceable 1910 Tub/Surround Serviceable 1911 Tub Enclosure Serviceable 1912 Tub Faucet Serviceable 1913 Shower/Surround Serviceable 1914 Shower Door Serviceable 1915 Shower Faucet Serviceable 1916 Sink Cracks noted recommend review and repairs by a licensed plumber 1917 Sink Faucet Serviceable 1918 Traps/Drain Serviceable Supply 1919 Toilet Serviceable 1920 Counter Granite Serviceable 1921 Cabinets Serviceable 1922 Spa Tub None 1923 Bathroom No additional comments Comments Page 32

33 Bathroom PLATINUM AVENUE PROPERTIES HOME INSPECTIONS Our focus in bathrooms is directed at identifying visible water damage and/or visible plumbing problems. Cosmetic issues such as common rust, common corrosion and/or stains may not always be reported. Step Components Comments 1901 Location Guest 1902 Floor Tile 1903 Walls Serviceable 1904 Ceiling Serviceable 1905 Doors Serviceable 1906 Windows/Screens Serviceable 1907 Electrical Serviceable Ground Fault Interrupter noted 1908 Exhaust Fan Serviceable 1909 Heat Source Serviceable 1910 Tub/Surround Serviceable 1911 Tub Enclosure Serviceable 1912 Tub Faucet Serviceable 1913 Shower/Surround Serviceable 1914 Shower Door Serviceable 1915 Shower Faucet Serviceable 1916 Sink Rusted sink noted recommend replacement Cracks noted recommend review and repairs by a licensed plumber 1917 Sink Faucet Serviceable 1918 Traps/Drain Serviceable Supply 1919 Toilet Serviceable 1920 Counter Serviceable 1921 Cabinets Serviceable 1922 Spa Tub None 1923 Bathroom No additional comments Comments Page 33

34 Bedroom: PLATINUM AVENUE PROPERTIES HOME INSPECTIONS Step Components Comments 2201 Location Bedroom 1 East/Back of property 2202 Floor Carpet 2203 Walls Serviceable 2204 Ceiling Serviceable 2205 Doors Serviceable 2206 Windows/Screens Serviceable 2207 Electrical Arc Fault Interrupters noted in Main Electrical Panel 2208 Closets/Wardrobe Serviceable 2209 Heat Source Serviceable Bedroom: Step Components Comments 2201 Location Bedroom 2 West/Back of property 2202 Floor Carpet 2203 Walls Serviceable 2204 Ceiling Serviceable 2205 Doors Serviceable 2206 Windows/Screens Serviceable 2207 Electrical Arc Fault Interrupters noted in Main Electrical Panel 2208 Closets/Wardrobe Serviceable 2209 Heat Source Serviceable Page 34

35 Bedroom: PLATINUM AVENUE PROPERTIES HOME INSPECTIONS Step Components Comments 2201 Location Master Bedroom 2202 Floor Carpet 2203 Walls Serviceable 2204 Ceiling Serviceable 2205 Doors Serviceable 2206 Windows/Screens Serviceable 2207 Electrical Arc Fault Interrupters noted in Main Electrical Panel 2208 Closets/Wardrobe Serviceable 2209 Heat Source Serviceable Page 35

36 Pool: Step Components Comments 3001 Decking Concrete common cracks noted 3002 Walkways Concrete common cracks noted 3003 Tile Serviceable 3004 Dive Board None 3005 Hand Rails None 3006 Fences/Gate Serviceable spring loaded safety latch 3007 Electrical System Serviceable ground wire noted for safety 3008 Lights Serviceable 3009 Receptacles Serviceable 3010 GFCI Not breaking properly recommend review and replacement by a licensed electrician Heater None 3012 Filter System Serviceable 3013 Pump Serviceable 3014 Motor Serviceable 3015 Timer System Serviceable 3016 Pool Comments Pool levels at each end are not even. Recommend review by a licensed pool contractor/technician. All pool/spa inspections are conducted above the water line. This inspection pertains only to the equipment mechanisms for the pool operation. No structural inspection of pool is performed. No leak tests (under ground pipes) are performed. Recommend consulting the seller about past water bills. This may indicate excessive pool water consumption. For more detailed information contact a licensed pool technician. Page 36

37 Page 37

38 Page 38

39 Page 39

40 Page 40

41 Page 41

42 Page 42

43 Page 43

44 Page 44

45 Page 45

46 Page 46

47 Page 47

48 Page 48

49 Page 49

50 Page 50

51 Page 51

52 Page 52

53 Page 53

54 Page 54

55 Page 55

56 Page 56

57 Page 57

58 Page 58

59 Page 59

60 Page 60

61 Page 61

62 Page 62

63 Page 63

64 Page 64

65 Page 65

66 Page 66

67 Page 67

68 Page 68

69 Page 69

70 Page 70

71 Page 71

72 Page 72

73 Page 73

74 Page 74

75 Page 75

76 Page 76

77 Page 77

78 Page 78

79 Page 79

80 Page 80

81 Page 81

82 Page 82

83 Page 83

84 Page 84

85 Page 85

86 Page 86

87 Page 87

88 Page 88

89 Page 89

90 Page 90

91 Page 91

92 Page 92

93 Page 93

94 Page 94

95 Page 95

96 Page 96

97 Page 97

98 Page 98

99 Page 99

100 Page 100

101 Page 101

102 Page 102

103 Page 103

104 Page 104

105 Page 105

106 Page 106

107 Page 107

108 Page 108