CLASSROOM MODIFICATIONS AT MURRAY LASAINE ELEMENTARY

Size: px
Start display at page:

Download "CLASSROOM MODIFICATIONS AT MURRAY LASAINE ELEMENTARY"

Transcription

1 MODIFICATIONS AT PROGRAM MANAGER ARCHITECT CIVIL ENGINEER MEP ENGINEER 399 BRIDGEVIEW DRIVE NORTH CHARLESTON, SC CONT: RONALD KRAMPS CUMMING CONSTRUCTION CORPORATION 3896 LEEDS AVENUE NORTH CHARLESTON, SC CONT: ROBERT FAUST MT PLEASANT, SC CONT: JOHN CICCARELLI SEAMON, WHITESIDES & ASSOCIATES 50 WANDO PARK BLVD, SUITE CONT: LEE GASTLEY EPIC ENGINEERING PO Box 232 MT PLEASANT, SC CONT: AARON TEMPEL WORK ITEM 8 0 DOOR NUMBER PT8 PAINT COLOR PL8 PLASTIC LAMINATE COLOR DETAIL NUMBER SHEET NUMBER SIM ENLARGED PLAN/DETAIL SHEET NUMBER SIM SECTION TAG 69 RIVERLAND DRIVE CHARLESTON, SC DETAIL NUMBER Room name 0 50 SF [Occupancy ] ROOM TAG DETAIL NUMBER Ref Ref Ref INTERIOR ELEVATION Ref SHEET NUMBER NORTH ARROW REVISIONS EXISTING PARTITIONS NEW PARTITIONS ITEMS TO BE REMOVED FIRE-RATED - ONE HOUR FIRE-RATED - TWO HOUR 0 5 ROOM FINISH SCHEDULE RM NO 86 86S 87 AREAS OF WORK ROOM NAME BASE B- B- B- SOUTH WEST CEILING PT-5 PT-5 PT-5 CEILING HGHT 3' - 0" 8' - 0" 3' - 0" COMMENTS CEILING HEIGHT VARIES SEE PLAN FOR ACCENT CEILING HEIGHT VARIES FINISH DESCRIPTIONS ITEM SHADED REGION GENERALLY REPRESENTS THE PRIMARY WORK REGIONS, THE CONTROR SHALL BE PREPARED TO PERFORM WORK IN OTHER PORTIONS OF THE BUILDING EITHER IDENTIFIED IN THE CONTR DOCUMENTS OR AS DETERMINED BY THE OWNER DURING CONSTRUCTION ITEMS SPANNING AREA OF WORK AND ADJACENT AREAS (IE DOORS) SHALL BE CONSIDERED WITHIN THE AREA OF WORK EAST SEE FOR ACCENT LOCATIONS EXTERIOR WORK NEW FENCE AND HARDSCAPE SEE C0 INTERIOR WORK SHADED REGION = AREA OF RECONFIGURED SPACE FLOOR C/VCT- C C NORTH BASE FLOOR FLOOR DOOR DOOR FRAME CEILING KEY NAME B- VCT- C PT-3 PT-4 PT-5 FINISH DESCRIPTION RUBBER BASE TEXAS GRANITE CARPET TILES PAINT - FIELD PAINT - ACCENT PAINT - DOOR PAINT - DOOR FRAME PAINT - GWB MANUFURER / COLOR TO BE DETERMINED TO BE DETERMINED TO BE DETERMINED ABBREVIATIONS AFF ALUM BLDG CAB CIP CLG CMU CONC CONST CONT CJ CT DEMO DIA DIMS DN DS DWG EQ EXST EXT EWC FEC FIN FF FFE FT GALV GA GLAZ GWB HC HGT HM HR INT LF MFR MSNRY MAT MAX MTL MIN MO NC N NIC NA NTE NTS OC OH OF/CI OP PT PWD QT RCP REQD RH RO RB SIM SF SS TLT TSE TYP UNO VCT WH W/ W/O WD ABOVE FINISH FLOOR ALUMINUM BUILDING CABINET CAST-IN-PLACE CEILING CONCRETE MASONRY UNIT CONCRETE CONSTRUCTION CONTINUOUS CONTROL JOINT CERAMIC TILE DEMOLITION DIAMETER DIMENSIONS DOWN DOWNSPOUT DRAWING EQUAL EXISTING EXTERIOR ELECTRIC WATER COOLER FIRE EXTINGUISHER CABINET FINISH FINISH FLOOR FINISH FLOOR ELEVATION FOOT/FEET GALVANIZED GAUGE GLAZING GYPSUM BOARD HANDICAP HEIGHT HOLLOW METAL HOUR INTERIOR LINEAR FEET MANUFURER MASONRY MATERIAL MAXIMUM METAL MINIMUM MASONRY OPENING NON-COMBUSTIBLE NORTH NOT IN CONTR NOT APPLICABLE NOT TO EXCEED NOT TO SCALE ON CENTER OPPOSITE HAND OWNER FURNISHED/CONTROR INSTALLED OWNER PROVIDED PAINT QUARRY TILE REFLECTED CEILING PLAN REQUIRED RIGHT HAND ROUGH OPENING RUBBER BASE SIMILAR SQUARE FOOT/FEET STAINLESS STEEL TOILET TOP OF STEEL ELEVATION TYPICAL UNLESS NOTED OTHERWISE VINYL COMPOSITE TILE WATER HEATER WITH WITHOUT WOOD GENERAL NOTES THE FOLLOWING NOTES APPLY TO ALL SHEETS WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE MOST CURRENT EDITION OF: INTERNATIONAL BUILDING CODE (IBC) 205 ALL FEDERAL,STATE AND LOCAL CODES AND ORDINANCES WHICH APPLY TO THIS WORK CONTROR SHALL VERIFY EXISTING FIELD DIMENSIONS AND UAL QUANTITY OF UNIT-PRICE ITEMS BEFORE BEGINNING WORK INCONSISTENCIES SHALL BE REPORTED TO THE ARCHITECT IMMEDIATELY "ALIGN" AS INDICATED ON THE DRAWINGS SHALL BE UNDERSTOOD TO MEAN THE FACE OF S OR COLUMNS INDICATED WORK OF THE ENGINEERING DISCIPLINES IS SHOWN ON ARCHITECTURAL DRAWINGS FOR COORDINATION PURPOSES ONLY REFER TO APPROPRIATE DISCIPLINE DRAWINGS FOR COMPLETE AND GOVERNING INFORMATION REGARDING THEIR WORK INCOMPLETE, INCONSISTENT OR MISSING ENGINEERING INFORMATION ON ARCHITECTURAL DRAWINGS SHALL NOT BE CONSTRUED AS BINDING FOR THAT WORK 5 STUDENTS WILL OCCUPY PORTIONS OF THE SCHOOL DURING CONSTRUCTION IVITIES CONTROR SHALL BE RESPONSIBLE FOR MAINTAINING PHYSICAL SEPARATION BETWEEN STUDENTS AND AREA OF WORK CONTROR SHALL BE RESPONSIBLE FOR MAINTAINING PROTECTED EGRESS PATHS THROUGHOUTCONSTRUCTION PERIOD PROVIDE FINISHED BEHIND ALL EQUIPMENT AND CASEWORK DO NOT SCALE DRAWINGS USE DIMENSIONS ONLY UNLESS NOTED OTHERWISE, DIMENSIONS ARE TYPICALLY SHOWN TO: - COLUMN CENTERLINES - FACE OF UNIT MASONRY - FACE OF STUD S SEE FOR DEMOLITION PLANS SEE T-00 FOR FINISH SCHEDULE PATCH OR REPAIR ALL AREAS/SURFACES WHERE CONSTRUCTION IVITIES OR EQUIPMENT LEAVES EXPOSED CONSTRUCTION OTHER THAN SMOOTH AND FLUSH REPAIR REMAINING EXISTING FINISHES WITH MATERIALS OF IDENTICAL MANUFURER, COLOR AND PATTERN INSTALL ACOUSTICAL SEALANTS AROUND DUCT, PIPE, AND CONDUIT PENETRATIONS THROUGH ALL INTERIOR PARTITIONS INSTALL FIRESTOPPING AT RATED PARTITIONS AS REQUIRED ALL RATED ASSEMBLIES FOR ITEMS PENETRATING FIRE RATED S SHALL BE INSTALLED BY A SINGLE VENDOR FOR ALL DISCIPLINES PROVIDE UL TESTED CMU FOR REPAIR OF FIRE RATED S TITLE SHEET TOO LS00 C0 C02 P00 P0 E00 E0 PROJECT NO 7004 INDEX OF DRAWINGS TITLE SHEET LIFE SAFETY PLAN SITE PLAN SITE DETAILS PARTIAL FLOOR PLANS AND DETAILS NOTES, LEGEND, SCHEDULES PLUMBING PLANS NOTES, LEGEND, SCHEDULES ELECTRICAL PLANS TOO REFERENCE SYMBOLS LOCATION MAP OWNER john@jcarchitectnet SHEET OF

2 ' - 0" 86S 47 SF SF SF (39 OCC) (38 OCC) 6' - 0" (8 OCC) (39 OCC) LIFE SAFETY PLAN 5' - 0" PROJECT NO ' - 0" TOTAL TRAVEL 85 FEET LIFE SAFETY PLAN /8" = '-0" LS00 SHEET 2 OF

3 3

4 4

5 A PARTIAL RCP - AREA A /8" = '-0" OPEN 4 3' - 0" 2' - 0" CLEAR 86 FIELD VERIFY EX LOCATION OF CROSS BRACING AND COORDINATE WITH ARCHITECT PRIOR TO REMOVAL OF DOOR, FRAME OR SEGMENT T 4 LIGHT FIXTURES SEE ELECTRICAL DRAWINGS 86S T = TEMPERED GLASS EXISTING GWB CEILING EXISTING GWB PARTITION REMOVE PORTION OF AND INSTALL BOX HEADER AS REQUIRED FOR INSTALLATION OF STOREFRONT BOX HEADER CORNER BEAD ALUMINUM STOREFRONT CARPET 3 STOREFRONT ELEVATION DETAIL STOREFRONT HEAD 4 3/8" = '-0" /2" = '-0" 4' - 6" 4' - 6" A B C A B C A B 2 W2 W3 FLOOR PLAN /8" = '-0" SF 2 3 D3 6' - 0" W9 W5 D W3 W0 W9 W2 W W8 W8 D6 D7 D SF 8 D3 W 3 5' - 6" 5' - 0" 2' - 0" D2 3' - 0" 5' - 6" CLEAR D0 D D5 W5 JAN W2 W3 D2 86S STORAGE STO 47 SF CORRIDOR ALTERNATE # BASE CABINETS, CABINETS AND COUNTERTOP IN AREA IDENTIFIED BOYS STORAGE GIRLS KILN WORK ITEMS W FLOOR TILE AND RUBBER BASE (BY OWNER) W2 CARPET TILE AND RUBBER BASE (BY OWNER) W3 PAINT ALL PREVIOUSLY PAINTED SURFACES SEE FINISH SCHEDULE W5 PLASTIC LAMINATE COUNTERTOP AND BACKSPLASH COLOR AND PATTERN TO BE SELECTED BY ARCHITECT FROM MANUFURER'S FULL RANGE OF STANDARD PATTERNS CUSTOM CABINETRY PLASTIC LAMINATE COLOR AND PATTERN TO BE SELECTED BY ARCHITECT FROM MANUFURER'S FULL RANGE OF STANDARD PATTERNS W8 KNEE SPACE W9 REFRIGERATOR (BY OWNER) W0 DISHWASHER W SINK - SEE PLUMBING DRAWINGS W3 NOT USED W8 SOAP DISPENSER W9 REINSTALL EXISTING PAPER TOWEL DISPENSER DEMOLITION ITEMS D REMOVE OR PORTION OF AS INDICATED ON DEMOLITION PLAN REPAIR FLOOR, SOFFIT, CEILING AND ABUTTING S AS REQUIRED TO PREPARE FOR NEW FINISHES D2 REMOVE VCT FLOORING AND ASSOCIATED RUBBER BASE D3 REMOVE CARPET AND ASSOCIATED RUBBER BASE D5 REMOVE MARKER BOARD AND/OR TACK BOARD AND ASSOCIATED FASTENERS D6 REMOVE BASE CABINET, SINK AND ASSOCIATED PIPING D7 REMOVE CABINET AND ASSOCIATED FASTENERS D9 REMOVE ALL -MOUNTED ACCESSORIES FROM CABINET AREA D0 REMOVE DOOR, FRAME AND ASSOCIATED FASTENERS D7 D9 D D john@jcarchitectnet ' - " ' - " C /2" DADO 4 SIDES /2" DADO 4 SIDES 5 DEMO PLAN /8" = '-0" DEMO PHOTO " MIN 2' - " 8" 3/4" SHELF SHELF HOLES AT " OC WIRE PULL PLASTIC LAMINATE ON REMOVABLE ACCESS PANEL PLASTIC LAMINATE ON 5 /2" STAINLESS STEEL SCREWS AND FINISHING WASHERS 4" 7" 2' - 3" MIN 2' - 0" 2' - 6" 2' - 0" 2' - " 2' - 0" PLASTIC LAMINATE ON DRAWER PLASTIC LAMINATE ON SHELF HOLES AT " OC 3/4" SHELF WIRE PULL 4" ' - 0 /2" 6" 2' - 0" 2' - 0" 2' - 6" 3 2' - 0" 2' - 0" 2' - 6" 7 9' - 0" 3' - 0" 3' - 0" 3' - 0" W3 ALTERNATE # BASE CABINETS, CABINETS AND COUNTERTOP IN AREA IDENTIFIED 2' - 0" 6 3' - 3" ' - 6" 3' - 3" 2' - 0" 3' - 6" 3' - 0" 6" W8 W W9 W3 2 KEY PLAN PARTIAL FLOOR PLANS AND DETAILS PROJECT NO CABINET SINK CABINET SECTION - TYP 7 " = '-0" " = '-0" 4" 4" RESILIENT BASE 8 CABINET ELEVATION 3/8" = '-0" W8 W0 W9 SHEET 5 OF

6 NOTES, LEGEND, SCHEDULES PROJECT NO 762 RAD P00 SHEET 6 OF 9

7 john@jcarchitectnet SF SF 86S 47 SF PLUMBING PLANS PROJECT NO 762 RAD P0 SHEET 7 OF 9

8 NOTES, LEGEND, SCHEDULES PROJECT NO 762 RAD E00 SHEET 8 OF 9

9 ELECTRICAL PLANS PROJECT NO 762 RAD E0 SHEET 9 OF 9