29 SAN ANTONIO technology & security AUSTIN

30 SAN ANTONIO technology & security AUSTIN 7 7 GENERAL NOTES:. THE EXISTING CONDITIONS AS SHOWN ARE APPROXIMATELY CORRECT. NOT ALL EXISTING CONDITIONS ARE SHOWN. THE CONTRACTOR SHALL VISIT THE SITE TO FIELD VERIFY ALL EXISTING CONDITIONS AS REQUIRED TO PROPERLY PERFORM THE CONTRACT.. CONTRACTOR SHALL RESTORE ALL PENETRATIONS (EXISTING AND NEW) PROVIDED FOR DATA, VOICE AND VIDEO CABLE BACK TO THE ORIGINAL RATING OF THE WALL/STRUCTURE USING INTUMESCENT FIRE RATED PUTTY.. ALL CABLING SHALL BE PROPERLY SUPPORTED. ANY EXISTING CABLING TO REMAIN SHALL BE SUPPORTED PROPERLY AS PER CABLING SPECIFICATION. KEYED NOTES EXISTING TELECOMMUNICATIONS ROOM. ALL RACKS, LADDER RACKS, FIBER PANELS, AND CABLE MANAGEMENT IS TO REMAIN. BACKBONE FIBER SHALL REMAIN AND FULLY OPERATIONAL DURING THE PROJECT. ANY DAMAGE TO FIBER, ACTIVE EQUIPMENT OR ANY PASSIVE EQUIPMENT NOT SCHEDULED TO BE REMOVED SHALL BE REPAIRED OR REPLACES AT NO COST TO THE OWNER. ALL ELECTRONICS TO INCLUDE SWITCHES, UPS AND ETC. SHALL REMAIN IN PLACE AND FULLY FUNCTIONAL. EXISTING DATA/VOICE OUTLET TO BE REMOVED. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL -PAIR CABLES AND WORKSTATION CONNECTING HARDWARE TERMINATED AT THIS LOCATION. CONTRACTOR IS TO REMOVE EACH CABLE TO BE DEMOLISHED FROM THE PATCH PANEL OR TERMINATION BLOCK IN THE TELECOMMUNICATIONS ROOM, REMOVE THE ENTIRE LENGTH OF THE CABLE AND THE CORRESPONDING MODULAR CONNECTOR, FACEPLATE AND ACCESSORIES. NO ABANDONED CABLING IS TO BE LEFT ABOVE CEILING. EXISTING ELECTRONIC VIDEO SURVEILLANCE CAMERA AND CABLE TO REMAIN IN PLACE AND FULLY OPERATIONAL. PROTECT EQUIPMENT AND CABLING DURING CONSTRUCTION. EXISTING ELECTRONIC VIDEO SURVEILLANCE CAMERA TO BE REMOVED BY OWNER. COORDINATE DEMOLITION WITH UT POLICE DEPARTMENT PRIOR TO REMOVING CABLE. 6 EXISTING CARD READER AND CABLE TO REMAIN IN PLACE AND FULLY OPERATIONAL. PROTECT EQUIPMENT AND CABLING DURING CONSTRUCTION. EXISTING EMERGENCY PHONE AND CABLE TO REMAIN IN PLACE AND FULLY OPERATIONAL. PROTECT EQUIPMENT AND CABLING DURING CONSTRUCTION APPROXIMATE LOCATION OF EXISTING DAS ANTENNA. ONLY VERIZON WILL BE ALLOWED TO MOVE OR UNINSTALL THIS EQUIPMENT TO INCLUDE ANTENNA AND CABLING. COORDINATE WITH OWNER (IMS) AND VERIZON FOR ITS REMOVAL DURING DEMOLITION PHASE OF THE PROJECT. PROVIDE FOUR WEEKS ADVANCED NOTICE. EXISTING AUDIO VISUAL CABLING TO BE REMOVED. CONTRACTOR SHALL REMOVE AND RETURN TO OWNER ALL CABLING AND CONNECTING HARDWARE TERMINATED AT THIS LOCATION. CONTRACTOR IS TO REMOVE EACH CABLE TO BE DEMOLISHED FROM THE POINT OF ORIGIN TO THE POINT OF TERMINATION. REMOVE THE ENTIRE LENGTH OF THE CABLE AND THE CORRESPONDING FACEPLATE AND ACCESSORIES. NO ABANDONED CABLING IS TO BE LEFT ABOVE CEILING. EXISTING AUDIO VISUAL SPEAKER TO BE REMOVED. CONTRACTOR IS TO REMOVE EACH CABLE TO BE DEMOLISHED FROM THE POINT OF ORIGIN TO THE POINT OF TERMINATION. REMOVE THE ENTIRE LENGTH OF THE CABLE AND THE CORRESPONDING FACEPLATE AND ACCESSORIES. NO ABANDONED CABLING IS TO BE LEFT ABOVE CEILING COORDINATE REMOVAL OF EXISTING WIRELESS ACCESS POINT (WAP) WITH OWNER (IMS). EXISTING WALL PHONE VOICE OUTLET TO BE REMOVED. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL -PAIR CABLES AND WORKSTATION CONNECTING HARDWARE TERMINATED AT THIS LOCATION. CONTRACTOR IS TO REMOVE EACH CABLE TO BE DEMOLISHED FROM THE PATCH PANEL OR TERMINATION BLOCK IN THE TELECOMMUNICATIONS ROOM, REMOVE THE ENTIRE LENGTH OF THE CABLE AND THE CORRESPONDING MODULAR CONNECTOR, FACEPLATE AND ACCESSORIES. NO ABANDONED CABLING IS TO BE LEFT ABOVE CEILING. A STAINLESS STEEL BLANK COVER PLATE WILL BE INSTALLED AT THIS LOCATION

31 SAN ANTONIO technology & security AUSTIN GENERAL NOTES:. THE EXISTING CONDITIONS AS SHOWN ARE APPROXIMATELY CORRECT. NOT ALL EXISTING CONDITIONS ARE SHOWN. THE CONTRACTOR SHALL VISIT THE SITE TO FIELD VERIFY ALL EXISTING CONDITIONS AS REQUIRED TO PROPERLY PERFORM THE CONTRACT CONTRACTOR SHALL RESTORE ALL PENETRATIONS (EXISTING AND NEW) PROVIDED FOR DATA, VOICE AND VIDEO CABLE BACK TO THE ORIGINAL RATING OF THE WALL/STRUCTURE USING INTUMESCENT FIRE RATED PUTTY.. ALL CABLING SHALL BE PROPERLY SUPPORTED. ANY EXISTING CABLING TO REMAIN SHALL BE SUPPORTED PROPERLY AS PER CABLING SPECIFICATION. KEYED NOTES EXISTING TELECOMMUNICATIONS ROOM. ALL RACKS, LADDER RACKS, FIBER PANELS, AND CABLE MANAGEMENT IS TO REMAIN. BACKBONE FIBER SHALL REMAIN AND FULLY OPERATIONAL DURING THE PROJECT. ANY DAMAGE TO FIBER, ACTIVE EQUIPMENT OR ANY PASSIVE EQUIPMENT NOT SCHEDULED TO BE REMOVED SHALL BE REPAIRED OR REPLACES AT NO COST TO THE OWNER. ALL ELECTRONICS TO INCLUDE SWITCHES, UPS AND ETC. SHALL REMAIN IN PLACE AND FULLY FUNCTIONAL. EXISTING DATA/VOICE OUTLET TO BE REMOVED. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL -PAIR CABLES AND WORKSTATION CONNECTING HARDWARE TERMINATED AT THIS LOCATION. CONTRACTOR IS TO REMOVE EACH CABLE TO BE DEMOLISHED FROM THE PATCH PANEL OR TERMINATION BLOCK IN THE TELECOMMUNICATIONS ROOM, REMOVE THE ENTIRE LENGTH OF THE CABLE AND THE CORRESPONDING MODULAR CONNECTOR, FACEPLATE AND ACCESSORIES. NO ABANDONED CABLING IS TO BE LEFT ABOVE CEILING. EXISTING ELECTRONIC VIDEO SURVEILLANCE CAMERA AND CABLE TO REMAIN IN PLACE AND FULLY OPERATIONAL. PROTECT EQUIPMENT AND CABLING DURING CONSTRUCTION. 8 EXISTING ELECTRONIC VIDEO SURVEILLANCE CAMERA TO BE REMOVED BY OWNER. COORDINATE DEMOLITION WITH UT POLICE DEPARTMENT PRIOR TO REMOVING CABLE. EXISTING CARD READER AND CABLE TO REMAIN IN PLACE AND FULLY OPERATIONAL. PROTECT EQUIPMENT AND CABLING DURING CONSTRUCTION EXISTING EMERGENCY PHONE AND CABLE TO REMAIN IN PLACE AND FULLY OPERATIONAL. PROTECT EQUIPMENT AND CABLING DURING CONSTRUCTION. APPROXIMATE LOCATION OF EXISTING DAS ANTENNA. ONLY VERIZON WILL BE ALLOWED TO MOVE OR UNINSTALL THIS EQUIPMENT TO INCLUDE ANTENNA AND CABLING. COORDINATE WITH OWNER (IMS) AND VERIZON FOR ITS REMOVAL DURING DEMOLITION PHASE OF THE PROJECT. PROVIDE FOUR WEEKS ADVANCED NOTICE. EXISTING AUDIO VISUAL CABLING TO BE REMOVED. CONTRACTOR SHALL REMOVE AND RETURN TO OWNER ALL CABLING AND CONNECTING HARDWARE TERMINATED AT THIS LOCATION. CONTRACTOR IS TO REMOVE EACH CABLE TO BE DEMOLISHED FROM THE POINT OF ORIGIN TO THE POINT OF TERMINATION. REMOVE THE ENTIRE LENGTH OF THE CABLE AND THE CORRESPONDING FACEPLATE AND ACCESSORIES. NO ABANDONED CABLING IS TO BE LEFT ABOVE CEILING. EXISTING AUDIO VISUAL SPEAKER TO BE REMOVED. CONTRACTOR IS TO REMOVE EACH CABLE TO BE DEMOLISHED FROM THE POINT OF ORIGIN TO THE POINT OF TERMINATION. REMOVE THE ENTIRE LENGTH OF THE CABLE AND THE CORRESPONDING FACEPLATE AND ACCESSORIES. NO ABANDONED CABLING IS TO BE LEFT ABOVE CEILING COORDINATE REMOVAL OF EXISTING WIRELESS ACCESS POINT (WAP) WITH OWNER (IMS). EXISTING WALL PHONE VOICE OUTLET TO BE REMOVED. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL -PAIR CABLES AND WORKSTATION CONNECTING HARDWARE TERMINATED AT THIS LOCATION. CONTRACTOR IS TO REMOVE EACH CABLE TO BE DEMOLISHED FROM THE PATCH PANEL OR TERMINATION BLOCK IN THE TELECOMMUNICATIONS ROOM, REMOVE THE ENTIRE LENGTH OF THE CABLE AND THE CORRESPONDING MODULAR CONNECTOR, FACEPLATE AND ACCESSORIES. NO ABANDONED CABLING IS TO BE LEFT ABOVE CEILING. A STAINLESS STEEL BLANK COVER PLATE WILL BE INSTALLED AT THIS LOCATION

32 SAN ANTONIO technology & security AUSTIN 0 GENERAL NOTES. ALL CONDUIT PATHWAYS, ROUGH-INS, CONDUIT SLEEVES, ETC. INDICATED ON THE TECHNOLOGY AND SECURITY DRAWINGS ARE TO BE PROVIDED AND INSTALLED BY DIVISION 6.. ALL POWER INDICATED ON THE TECHNOLOGY AND SECURITY DRAWINGS ARE TO BE PROVIDED AND INSTALLED BY DIVISION 6.. CONTRACTOR SHALL RESTORE ALL PENETRATIONS PROVIDED THROUGH FIRE RATED WALLS/STRUCTURES FOR DATA, VOICE, AND SECURITY CABLING BACK TO THE ORIGINAL RATING.. CONTRACTOR SHALL RESTORE ALL PENETRATIONS PROVIDED THROUGH NON-RATED WALLS/STRUCTURES FOR DATA, VOICE, AND SECURITY CABLING FOR SOUND TO REDUCE NOISE TRAVELING THROUGH PENETRATIONS.. CABLING FOR DATA, VOICE, AND SECURITY SHALL BE ROUTED IN SEPARATE PATHWAYS IN J-HOOKS, CONDUITS, CONDUIT SLEEVES, CORES, ETC. THROUGHOUT THE ENTIRE PATHWAY. DIFFERENT MEDIA TYPES (DATA, VOICE, SECURITY, ETC.) SHALL NOT SHARE THE SAME J-HOOK, CONDUIT, CONDUIT SLEEVE, CORE, ETC. 6. ALL CONDUITS FOR DATA, VOICE, A/V, AND SECURITY DEVICES SHALL ROUTE FROM THE DEVICE LOCATION AND TERMINATE ABOVE AN ACCESSIBLE CEILING IN THE SAME ROOM WHERE THE DEVICE IS IF THE ROOM WHERE THE DEVICE IS LOCATED DOES NOT HAVE AN ACCESSIBLE CEILING, THE CONDUIT SHALL ROUTE TO THE NEAREST ACCESSIBLE CEILING A MAIN CORRIDOR. CONDUIT PATHWAY SHALL TAKE THE SHORTEST ROUTE TO THE APPLICABLE MDF/IDF ROOM TO MINIMIZE CABLE LENGTH. IF A ROOM HAS A CLOUDED CEILING, HARD CEILING, OR THE ROOM IS OPEN TO ROOF DECK THESE ARE NOT CONSIDERED AN ACCESSIBLE CEILING ENVIRONMENT CONDUIT SEGMENTS SHALL BE NO MORE THAN 00-FEET IN LENGTH WITH NO MORE THAN THE EQUIVALENT OF () 90 DEGREE BENDS BETWEEN PULLING POINTS. 8. CONDUITS SHALL MAINTAIN A BEND RADIUS OF 6 TIMES THE DIAMETER OF THE CONDUIT FOR CONDUITS -INCHES OR SMALLER AND 0 TIMES THE DIAMETER OF THE CONDUIT FOR CONDUITS GREATER THAN -INCHES. 9. ALL CONDUITS SHALL HAVE A PULL STRING INSTALLED FOR PULLING OF CABLE. CLEARLY LABEL AS "PULL STRING" INDICATING OPPOSITE END LOCATION. 0. ALL SPARE CONDUITS OR CONDUITS FILLED WITH LESS THAN THE MAXIMUM ALLOWED FILL RATIO SHALL HAVE A PULL STRING INSTALLED AND LEFT FOR FUTURE PULLING OF CABLE. CLEARLY LABEL AS "PULL STRING" INDICATING OPPOSITE END LOCATION.. CONTRACTOR SHALL COORDINATE THE REINSTALLATION OF ALL DISTRIBUTED ANTENNA SYSTEM (DAS) ANTENNAS AND CABLING WITH VERIZON. THEY HOLD THE CONTRACT AND MUST BE HIRED TO ACCOMPLISH ALL WORK.. ALL CABLING FOR SYSTEMS FURNITURE SHALL BE ROUTED THROUGH THE FURNITURE. COORDINATE WITH SYSTEMS FURNITURE MANUFACTURER FOR ROUTING THROUGH THE FURNITURE. KEYED NOTES 0 0 () -INCH EMT CONDUIT SLEEVE ABOVE ACCESSIBLE CEILING WITH NYLON BUSHING ON EACH END AND SECURED TO WALL. CONDUIT SLEEVE SHALL BE PROPERLY SEALED ON THE EXTERIOR AND INTERIOR TO RETURN WALL BACK TO ORIGINAL RATING. IF WALL IS NOT RATED, CONDUIT SLEEVE SHALL BE PROPERLY SEALED ON THE EXTERIOR AND INTERIOR TO REDUCE NOISE TRAVELING THROUGH PENETRATIONS. CONDUIT SLEEVE SHALL BE USED FOR LOW VOLTAGE DATA, VOICE, AND SECURITY CABLE ONLY. () -INCH EMT CONDUIT SLEEVES ABOVE ACCESSIBLE CEILING WITH NYLON BUSHING ON EACH END AND SECURED TO WALL. CONDUIT SLEEVES SHALL BE PROPERLY SEALED ON THE EXTERIOR AND INTERIOR TO RETURN WALL BACK TO ORIGINAL RATING. IF WALL IS NOT RATED, CONDUIT SLEEVES SHALL BE PROPERLY SEALED ON THE EXTERIOR AND INTERIOR TO REDUCE NOISE TRAVELING THROUGH PENETRATIONS. CONDUIT SLEEVES SHALL BE USED FOR LOW VOLTAGE DATA, VOICE, AND SECURITY CABLE ONLY. DATA CABLE FOR MODULAR FURNITURE. COORDINATE THE PROPER INSERT WITH FURNITURE MANUFACTURER. CABLES WILL BE ROUTED THROUGH FURNITURE TO LOCATION NOTED ON DRAWING. DATA CABLE WITH 0-FEET OF SLACK NEATLY COILED AND STORED ON J-HOOK ABOVE ACCESSIBLE CEILING FOR OWNER PROVIDED / OWNER INSTALLED CEILING MOUNTED WIRELESS ACCESS POINT. CONTRACTOR SHALL PLACE A GREEN ADHESIVE DOT ON THE CEILING GRID DIRECTLY BELOW THE OUTLET LOCATION FOR FUTURE IDENTIFICATION OF THE OUTLET LOCATION. DATA CABLE WITH 0-FEET OF SLACK NEATLY COILED AND STORED ON J-HOOK ABOVE ACCESSIBLE CEILING FOR OWNER PROVIDED / OWNER INSTALLED INTERIOR CEILING MOUNTED VIDEO SURVEILLANCE CAMERA. CONTRACTOR SHALL PLACE A YELLOW ADHESIVE DOT ON THE CEILING GRID DIRECTLY BELOW THE OUTLET LOCATION FOR FUTURE IDENTIFICATION OF THE OUTLET A.F.F. 6 DATA CABLE WITH 0-FEET OF SLACK NEATLY COILED AND STORED ON J-HOOK ABOVE ACCESSIBLE CEILING FOR OWNER PROVIDED / OWNER INSTALLED INTERIOR CEILING MOUNTED VIDEO SURVEILLANCE CAMERA. CONTRACTOR SHALL PLACE A YELLOW ADHESIVE DOT ON THE CEILING GRID DIRECTLY BELOW THE OUTLET LOCATION FOR FUTURE IDENTIFICATION OF THE OUTLET A.F.F. 7 DATA CABLE FOR OWNER PROVIDED / OWNER INSTALLED EXTERIOR WALL MOUNTED VIDEO SURVEILLANCE CAMERA. A.F.F DATA CABLES FOR OWNER PROVIDED / OWNER INSTALLED ACCESS CONTROL SECURITY PANEL. COORDINATE EXACT LOCATION FOR CONDUIT ROUGH-IN AND TERMINATION REQUIREMENTS WITH SECURITY CONTRACTOR PRIOR TO INSTALLATION. FLOOR BOX AS SPECIFIED BY DIVISION 6. PROVIDE () -INCH CONDUIT DEDICATED FOR DATA CABLE AND () -INCH CONDUIT DEDICATED FOR AUDIO VISUAL CABLE FROM THE FLOOR BOX TO ABOVE ACCESSIBLE CEILING IN THE SAME ROOM WHERE THE FLOOR BOX IS LOCATED. PROVIDE PULL STRING IN CONDUIT AND NYLON BUSHING ON EACH END OF CONDUIT. REFER TO ARCHITECTURAL AND ELECTRICAL DRAWINGS FOR EXACT LOCATION AND ADDITIONAL CONDUIT ROUGH-IN REQUIREMENTS PRIOR TO INSTALLATION. ALL CAMERAS ARE FOR REFERENCE ONLY. CAMERAS WILL BE OWNER PROVIDED / OWNER INSTALLED. ALL CARD READERS ARE FOR REFERENCE ONLY. CARD READERS WILL BE OWNER PROVIDED / OWNER INSTALLED. ALL WIRELESS ACCESS POINTS (WAPS) ARE FOR REFERENCE ONLY. WAPS WILL BE OWNER PROVIDED / OWNER INSTALLED. CARD READER COMPOSITE CABLING SHALL BE INSTALLED AT THIS LOCATION PER SPECIFICATIONS AND TYPICAL DETAILS. ALL CARD READERS ARE FOR REFERENCE ONLY. CARD READERS WILL BE OWNER PROVIDED / OWNER INSTALLED. EXISTING ELECTRONIC VIDEO SURVEILLANCE CAMERA AND CABLE TO REMAIN IN PLACE AND FULLY OPERATIONAL. PROTECT EQUIPMENT AND CABLING DURING CONSTRUCTION. EXISTING CARD READER AND CABLE TO REMAIN IN PLACE AND FULLY OPERATIONAL. PROTECT EQUIPMENT AND CABLING DURING CONSTRUCTION. 6 EXISTING EMERGENCY PHONE AND CABLE TO REMAIN IN PLACE AND FULLY OPERATIONAL. PROTECT EQUIPMENT AND CABLING DURING A.F.F PROVIDE AND INSTALL DOOR BELL EATON PART NUMBER - PUSH BUTTON HT8AAHAB WITH STAINLESS STEEL PLATE OR APPROVED EQUIVALENT. PROVIDE AND INSTALL PLENUM RATED BELDON AWG CONDUCTOR CABLE OR EQUIVALENT. PROVIDE AND INSTALL DOOR CHIME HONEYWELL PART NUMBER - RCW0N008-WIRED OR APPROVED EQUIVALENT. PROVIDE AND INSTALL LYNX DURESS BUTTON - PART NUMBER - LYNX-N-PP-M. PROVIDE AND INSTALL DOOR RELEASE BUTTON SDC SECURITY PART NUMBER - -. PROVIDE AND INSTALL PLENUM RATED BELDON AWG CONDUCTOR CABLE OR EQUIVALENT. DATA CABLE WITH 0-FEET OF SLACK NEATLY COILED AND STORED ON J-HOOK ABOVE ACCESSIBLE CEILING FOR OWNER PROVIDED / OWNER INSTALLED ACCESS CONTROL DOORS. CONTRACTOR SHALL PLACE A YELLOW ADHESIVE DOT ON THE CEILING GRID DIRECTLY BELOW THE OUTLET LOCATION FOR FUTURE IDENTIFICATION OF THE OUTLET LOCATION.

33 SAN ANTONIO technology & security AUSTIN GENERAL NOTES. ALL CONDUIT PATHWAYS, ROUGH-INS, CONDUIT SLEEVES, ETC. INDICATED ON THE TECHNOLOGY AND SECURITY DRAWINGS ARE TO BE PROVIDED AND INSTALLED BY DIVISION 6.. ALL POWER INDICATED ON THE TECHNOLOGY AND SECURITY DRAWINGS ARE TO BE PROVIDED AND INSTALLED BY DIVISION A.F.F CONTRACTOR SHALL RESTORE ALL PENETRATIONS PROVIDED THROUGH FIRE RATED WALLS/STRUCTURES FOR DATA, VOICE, AND SECURITY CABLING BACK TO THE ORIGINAL RATING.. CONTRACTOR SHALL RESTORE ALL PENETRATIONS PROVIDED THROUGH NON-RATED WALLS/STRUCTURES FOR DATA, VOICE, AND SECURITY CABLING FOR SOUND TO REDUCE NOISE TRAVELING THROUGH PENETRATIONS.. CABLING FOR DATA, VOICE, AND SECURITY SHALL BE ROUTED IN SEPARATE PATHWAYS IN J-HOOKS, CONDUITS, CONDUIT SLEEVES, CORES, ETC. THROUGHOUT THE ENTIRE PATHWAY. DIFFERENT MEDIA TYPES (DATA, VOICE, SECURITY, ETC.) SHALL NOT SHARE THE SAME J-HOOK, CONDUIT, CONDUIT SLEEVE, CORE, ETC. 6. ALL CONDUITS FOR DATA, VOICE, A/V, AND SECURITY DEVICES SHALL ROUTE FROM THE DEVICE LOCATION AND TERMINATE ABOVE AN ACCESSIBLE CEILING IN THE SAME ROOM WHERE THE DEVICE IS IF THE ROOM WHERE THE DEVICE IS LOCATED DOES NOT HAVE AN ACCESSIBLE CEILING, THE CONDUIT SHALL ROUTE TO THE NEAREST ACCESSIBLE CEILING A MAIN CORRIDOR. CONDUIT PATHWAY SHALL TAKE THE SHORTEST ROUTE TO THE APPLICABLE MDF/IDF ROOM TO MINIMIZE CABLE LENGTH. IF A ROOM HAS A CLOUDED CEILING, HARD CEILING, OR THE ROOM IS OPEN TO ROOF DECK THESE ARE NOT CONSIDERED AN ACCESSIBLE CEILING ENVIRONMENT. 7. CONDUIT SEGMENTS SHALL BE NO MORE THAN 00-FEET IN LENGTH WITH NO MORE THAN THE EQUIVALENT OF () 90 DEGREE BENDS BETWEEN PULLING POINTS CONDUITS SHALL MAINTAIN A BEND RADIUS OF 6 TIMES THE DIAMETER OF THE CONDUIT FOR CONDUITS -INCHES OR SMALLER AND 0 TIMES THE DIAMETER OF THE CONDUIT FOR CONDUITS GREATER THAN -INCHES. 9. ALL CONDUITS SHALL HAVE A PULL STRING INSTALLED FOR PULLING OF CABLE. CLEARLY LABEL AS "PULL STRING" INDICATING OPPOSITE END LOCATION. 0. ALL SPARE CONDUITS OR CONDUITS FILLED WITH LESS THAN THE MAXIMUM ALLOWED FILL RATIO SHALL HAVE A PULL STRING INSTALLED AND LEFT FOR FUTURE PULLING OF CABLE. CLEARLY LABEL AS "PULL STRING" INDICATING OPPOSITE END LOCATION.. CONTRACTOR SHALL COORDINATE THE REINSTALLATION OF ALL DISTRIBUTED ANTENNA SYSTEM (DAS) ANTENNAS AND CABLING WITH VERIZON. THEY HOLD THE CONTRACT AND MUST BE HIRED TO ACCOMPLISH ALL WORK.. ALL CABLING FOR SYSTEMS FURNITURE SHALL BE ROUTED THROUGH THE FURNITURE. COORDINATE WITH SYSTEMS FURNITURE MANUFACTURER FOR ROUTING THROUGH THE FURNITURE. KEYED NOTES A.F.F. () -INCH EMT CONDUIT SLEEVE ABOVE ACCESSIBLE CEILING WITH NYLON BUSHING ON EACH END AND SECURED TO WALL. CONDUIT SLEEVE SHALL BE PROPERLY SEALED ON THE EXTERIOR AND INTERIOR TO RETURN WALL BACK TO ORIGINAL RATING. IF WALL IS NOT RATED, CONDUIT SLEEVE SHALL BE PROPERLY SEALED ON THE EXTERIOR AND INTERIOR TO REDUCE NOISE TRAVELING THROUGH PENETRATIONS. CONDUIT SLEEVE SHALL BE USED FOR LOW VOLTAGE DATA, VOICE, AND SECURITY CABLE ONLY. () -INCH EMT CONDUIT SLEEVES ABOVE ACCESSIBLE CEILING WITH NYLON BUSHING ON EACH END AND SECURED TO WALL. CONDUIT SLEEVES SHALL BE PROPERLY SEALED ON THE EXTERIOR AND INTERIOR TO RETURN WALL BACK TO ORIGINAL RATING. IF WALL IS NOT RATED, CONDUIT SLEEVES SHALL BE PROPERLY SEALED ON THE EXTERIOR AND INTERIOR TO REDUCE NOISE TRAVELING THROUGH PENETRATIONS. CONDUIT SLEEVES SHALL BE USED FOR LOW VOLTAGE DATA, VOICE, AND SECURITY CABLE ONLY. DATA CABLE FOR MODULAR FURNITURE. COORDINATE THE PROPER INSERT WITH FURNITURE MANUFACTURER. CABLES WILL BE ROUTED THROUGH FURNITURE TO LOCATION NOTED ON DRAWING. DATA CABLE WITH 0-FEET OF SLACK NEATLY COILED AND STORED ON J-HOOK ABOVE ACCESSIBLE CEILING FOR OWNER PROVIDED / OWNER INSTALLED CEILING MOUNTED WIRELESS ACCESS POINT. CONTRACTOR SHALL PLACE A GREEN ADHESIVE DOT ON THE CEILING GRID DIRECTLY BELOW THE OUTLET LOCATION FOR FUTURE IDENTIFICATION OF THE OUTLET LOCATION DATA CABLE WITH 0-FEET OF SLACK NEATLY COILED AND STORED ON J-HOOK ABOVE ACCESSIBLE CEILING FOR OWNER PROVIDED / OWNER INSTALLED INTERIOR CEILING MOUNTED VIDEO SURVEILLANCE CAMERA. CONTRACTOR SHALL PLACE A YELLOW ADHESIVE DOT ON THE CEILING GRID DIRECTLY BELOW THE OUTLET LOCATION FOR FUTURE IDENTIFICATION OF THE OUTLET LOCATION. DATA CABLE WITH 0-FEET OF SLACK NEATLY COILED AND STORED ON J-HOOK ABOVE ACCESSIBLE CEILING FOR OWNER PROVIDED / OWNER INSTALLED INTERIOR CEILING MOUNTED VIDEO SURVEILLANCE CAMERA. CONTRACTOR SHALL PLACE A YELLOW ADHESIVE DOT ON THE CEILING GRID DIRECTLY BELOW THE OUTLET LOCATION FOR FUTURE IDENTIFICATION OF THE OUTLET LOCATION. DATA CABLE FOR OWNER PROVIDED / OWNER INSTALLED EXTERIOR WALL MOUNTED VIDEO SURVEILLANCE CAMERA. DATA CABLES FOR OWNER PROVIDED / OWNER INSTALLED ACCESS CONTROL SECURITY PANEL. COORDINATE EXACT LOCATION FOR CONDUIT ROUGH-IN AND TERMINATION REQUIREMENTS WITH SECURITY CONTRACTOR PRIOR TO INSTALLATION. FLOOR BOX AS SPECIFIED BY DIVISION 6. PROVIDE () -INCH CONDUIT DEDICATED FOR DATA CABLE AND () -INCH CONDUIT DEDICATED FOR AUDIO VISUAL CABLE FROM THE FLOOR BOX TO ABOVE ACCESSIBLE CEILING IN THE SAME ROOM WHERE THE FLOOR BOX IS LOCATED. PROVIDE PULL STRING IN CONDUIT AND NYLON BUSHING ON EACH END OF CONDUIT. REFER TO ARCHITECTURAL AND ELECTRICAL DRAWINGS FOR EXACT LOCATION AND ADDITIONAL CONDUIT ROUGH-IN REQUIREMENTS PRIOR TO INSTALLATION. ALL CAMERAS ARE FOR REFERENCE ONLY. CAMERAS WILL BE OWNER PROVIDED / OWNER INSTALLED. ALL CARD READERS ARE FOR REFERENCE ONLY. CARD READERS WILL BE OWNER PROVIDED / OWNER INSTALLED. ALL WIRELESS ACCESS POINTS (WAPS) ARE FOR REFERENCE ONLY. WAPS WILL BE OWNER PROVIDED / OWNER INSTALLED CARD READER COMPOSITE CABLING SHALL BE INSTALLED AT THIS LOCATION PER SPECIFICATIONS AND TYPICAL DETAILS. ALL CARD READERS ARE FOR REFERENCE ONLY. CARD READERS WILL BE OWNER PROVIDED / OWNER INSTALLED. EXISTING ELECTRONIC VIDEO SURVEILLANCE CAMERA AND CABLE TO REMAIN IN PLACE AND FULLY OPERATIONAL. PROTECT EQUIPMENT AND CABLING DURING CONSTRUCTION. EXISTING CARD READER AND CABLE TO REMAIN IN PLACE AND FULLY OPERATIONAL. PROTECT EQUIPMENT AND CABLING DURING CONSTRUCTION. 6 7 EXISTING EMERGENCY PHONE AND CABLE TO REMAIN IN PLACE AND FULLY OPERATIONAL. PROTECT EQUIPMENT AND CABLING DURING CONSTRUCTION. PROVIDE AND INSTALL DOOR BELL EATON PART NUMBER - PUSH BUTTON HT8AAHAB WITH STAINLESS STEEL PLATE OR APPROVED EQUIVALENT. PROVIDE AND INSTALL PLENUM RATED BELDON AWG CONDUCTOR CABLE OR EQUIVALENT A.F.F PROVIDE AND INSTALL DOOR CHIME HONEYWELL PART NUMBER - RCW0N008-WIRED OR APPROVED EQUIVALENT. PROVIDE AND INSTALL LYNX DURESS BUTTON - PART NUMBER - LYNX-N-PP-M. PROVIDE AND INSTALL DOOR RELEASE BUTTON SDC SECURITY PART NUMBER - -. PROVIDE AND INSTALL PLENUM RATED BELDON AWG CONDUCTOR CABLE OR EQUIVALENT. DATA CABLE WITH 0-FEET OF SLACK NEATLY COILED AND STORED ON J-HOOK ABOVE ACCESSIBLE CEILING FOR OWNER PROVIDED / OWNER INSTALLED ACCESS CONTROL DOORS. CONTRACTOR SHALL PLACE A YELLOW ADHESIVE DOT ON THE CEILING GRID DIRECTLY BELOW THE OUTLET LOCATION FOR FUTURE IDENTIFICATION OF THE OUTLET LOCATION.

34 SAN ANTONIO technology & security A.F.F GENERAL NOTES. ALL CONDUIT PATHWAYS, ROUGH-INS, CONDUIT SLEEVES, ETC. INDICATED ON THE TECHNOLOGY AND SECURITY DRAWINGS ARE TO BE PROVIDED AND INSTALLED BY DIVISION 6.. ALL POWER INDICATED ON THE TECHNOLOGY AND SECURITY DRAWINGS ARE TO BE PROVIDED AND INSTALLED BY DIVISION 6.. CONTRACTOR SHALL RESTORE ALL PENETRATIONS PROVIDED THROUGH FIRE RATED WALLS/STRUCTURES FOR DATA, VOICE, AND SECURITY CABLING BACK TO THE ORIGINAL RATING.. CONTRACTOR SHALL RESTORE ALL PENETRATIONS PROVIDED THROUGH NON-RATED WALLS/STRUCTURES FOR DATA, VOICE, AND SECURITY CABLING FOR SOUND TO REDUCE NOISE TRAVELING THROUGH PENETRATIONS.. CABLING FOR DATA, VOICE, AND SECURITY SHALL BE ROUTED IN SEPARATE PATHWAYS IN J-HOOKS, CONDUITS, CONDUIT SLEEVES, CORES, ETC. THROUGHOUT THE ENTIRE PATHWAY. DIFFERENT MEDIA TYPES (DATA, VOICE, SECURITY, ETC.) SHALL NOT SHARE THE SAME J-HOOK, CONDUIT, CONDUIT SLEEVE, CORE, ETC. 6. ALL CONDUITS FOR DATA, VOICE, A/V, AND SECURITY DEVICES SHALL ROUTE FROM THE DEVICE LOCATION AND TERMINATE ABOVE AN ACCESSIBLE CEILING IN THE SAME ROOM WHERE THE DEVICE IS IF THE ROOM WHERE THE DEVICE IS LOCATED DOES NOT HAVE AN ACCESSIBLE CEILING, THE CONDUIT SHALL ROUTE TO THE NEAREST ACCESSIBLE CEILING A MAIN CORRIDOR. CONDUIT PATHWAY SHALL TAKE THE SHORTEST ROUTE TO THE APPLICABLE MDF/IDF ROOM TO MINIMIZE CABLE LENGTH. IF A ROOM HAS A CLOUDED CEILING, HARD CEILING, OR THE ROOM IS OPEN TO ROOF DECK THESE ARE NOT CONSIDERED AN ACCESSIBLE CEILING ENVIRONMENT. 7. CONDUIT SEGMENTS SHALL BE NO MORE THAN 00-FEET IN LENGTH WITH NO MORE THAN THE EQUIVALENT OF () 90 DEGREE BENDS BETWEEN PULLING POINTS. 8. CONDUITS SHALL MAINTAIN A BEND RADIUS OF 6 TIMES THE DIAMETER OF THE CONDUIT FOR CONDUITS -INCHES OR SMALLER AND 0 TIMES THE DIAMETER OF THE CONDUIT FOR CONDUITS GREATER THAN -INCHES. 9. ALL CONDUITS SHALL HAVE A PULL STRING INSTALLED FOR PULLING OF CABLE. CLEARLY LABEL AS "PULL STRING" INDICATING OPPOSITE END LOCATION. 0. ALL SPARE CONDUITS OR CONDUITS FILLED WITH LESS THAN THE MAXIMUM ALLOWED FILL RATIO SHALL HAVE A PULL STRING INSTALLED AND LEFT FOR FUTURE PULLING OF CABLE. CLEARLY LABEL AS "PULL STRING" INDICATING OPPOSITE END LOCATION.. CONTRACTOR SHALL COORDINATE THE REINSTALLATION OF ALL DISTRIBUTED ANTENNA SYSTEM (DAS) ANTENNAS AND CABLING WITH VERIZON. THEY HOLD THE CONTRACT AND MUST BE HIRED TO ACCOMPLISH ALL WORK.. ALL CABLING FOR SYSTEMS FURNITURE SHALL BE ROUTED THROUGH THE FURNITURE. COORDINATE WITH SYSTEMS FURNITURE MANUFACTURER FOR ROUTING THROUGH THE FURNITURE. KEYED NOTES () -INCH EMT CONDUIT SLEEVE ABOVE ACCESSIBLE CEILING WITH NYLON BUSHING ON EACH END AND SECURED TO WALL. CONDUIT SLEEVE SHALL BE PROPERLY SEALED ON THE EXTERIOR AND INTERIOR TO RETURN WALL BACK TO ORIGINAL RATING. IF WALL IS NOT RATED, CONDUIT SLEEVE SHALL BE PROPERLY SEALED ON THE EXTERIOR AND INTERIOR TO REDUCE NOISE TRAVELING THROUGH PENETRATIONS. CONDUIT SLEEVE SHALL BE USED FOR LOW VOLTAGE DATA, VOICE, AND SECURITY CABLE ONLY. () -INCH EMT CONDUIT SLEEVES ABOVE ACCESSIBLE CEILING WITH NYLON BUSHING ON EACH END AND SECURED TO WALL. CONDUIT SLEEVES SHALL BE PROPERLY SEALED ON THE EXTERIOR AND INTERIOR TO RETURN WALL BACK TO ORIGINAL RATING. IF WALL IS NOT RATED, CONDUIT SLEEVES SHALL BE PROPERLY SEALED ON THE EXTERIOR AND INTERIOR TO REDUCE NOISE TRAVELING THROUGH PENETRATIONS. CONDUIT SLEEVES SHALL BE USED FOR LOW VOLTAGE DATA, VOICE, AND SECURITY CABLE ONLY. DATA CABLE FOR MODULAR FURNITURE. COORDINATE THE PROPER INSERT WITH FURNITURE MANUFACTURER. CABLES WILL BE ROUTED THROUGH FURNITURE TO LOCATION NOTED ON DRAWING. DATA CABLE WITH 0-FEET OF SLACK NEATLY COILED AND STORED ON J-HOOK ABOVE ACCESSIBLE CEILING FOR OWNER PROVIDED / OWNER INSTALLED CEILING MOUNTED WIRELESS ACCESS POINT. CONTRACTOR SHALL PLACE A GREEN ADHESIVE DOT ON THE CEILING GRID DIRECTLY BELOW THE OUTLET LOCATION FOR FUTURE IDENTIFICATION OF THE OUTLET LOCATION. DATA CABLE WITH 0-FEET OF SLACK NEATLY COILED AND STORED ON J-HOOK ABOVE ACCESSIBLE CEILING FOR OWNER PROVIDED / OWNER INSTALLED INTERIOR CEILING MOUNTED VIDEO SURVEILLANCE CAMERA. CONTRACTOR SHALL PLACE A YELLOW ADHESIVE DOT ON THE CEILING GRID DIRECTLY BELOW THE OUTLET LOCATION FOR FUTURE IDENTIFICATION OF THE OUTLET LOCATION. DATA CABLE WITH 0-FEET OF SLACK NEATLY COILED AND STORED ON J-HOOK ABOVE ACCESSIBLE CEILING FOR OWNER PROVIDED / OWNER INSTALLED INTERIOR CEILING MOUNTED VIDEO SURVEILLANCE CAMERA. CONTRACTOR SHALL PLACE A YELLOW ADHESIVE DOT ON THE CEILING GRID DIRECTLY BELOW THE OUTLET LOCATION FOR FUTURE IDENTIFICATION OF THE OUTLET LOCATION. DATA CABLE FOR OWNER PROVIDED / OWNER INSTALLED EXTERIOR WALL MOUNTED VIDEO SURVEILLANCE CAMERA. DATA CABLES FOR OWNER PROVIDED / OWNER INSTALLED ACCESS CONTROL SECURITY PANEL. COORDINATE EXACT LOCATION FOR CONDUIT ROUGH-IN AND TERMINATION REQUIREMENTS WITH SECURITY CONTRACTOR PRIOR TO INSTALLATION. FLOOR BOX AS SPECIFIED BY DIVISION 6. PROVIDE () -INCH CONDUIT DEDICATED FOR DATA CABLE AND () -INCH CONDUIT DEDICATED FOR AUDIO VISUAL CABLE FROM THE FLOOR BOX TO ABOVE ACCESSIBLE CEILING IN THE SAME ROOM WHERE THE FLOOR BOX IS LOCATED. PROVIDE PULL STRING IN CONDUIT AND NYLON BUSHING ON EACH END OF CONDUIT. REFER TO ARCHITECTURAL AND ELECTRICAL DRAWINGS FOR EXACT LOCATION AND ADDITIONAL CONDUIT ROUGH-IN REQUIREMENTS PRIOR TO INSTALLATION. ALL CAMERAS ARE FOR REFERENCE ONLY. CAMERAS WILL BE OWNER PROVIDED / OWNER INSTALLED. ALL CARD READERS ARE FOR REFERENCE ONLY. CARD READERS WILL BE OWNER PROVIDED / OWNER INSTALLED. ALL WIRELESS ACCESS POINTS (WAPS) ARE FOR REFERENCE ONLY. WAPS WILL BE OWNER PROVIDED / OWNER INSTALLED. CARD READER COMPOSITE CABLING SHALL BE INSTALLED AT THIS LOCATION PER SPECIFICATIONS AND TYPICAL DETAILS. ALL CARD READERS ARE FOR REFERENCE ONLY. CARD READERS WILL BE OWNER PROVIDED / OWNER INSTALLED. EXISTING ELECTRONIC VIDEO SURVEILLANCE CAMERA AND CABLE TO REMAIN IN PLACE AND FULLY OPERATIONAL. PROTECT EQUIPMENT AND CABLING DURING CONSTRUCTION. EXISTING CARD READER AND CABLE TO REMAIN IN PLACE AND FULLY OPERATIONAL. PROTECT EQUIPMENT AND CABLING DURING CONSTRUCTION. EXISTING EMERGENCY PHONE AND CABLE TO REMAIN IN PLACE AND FULLY OPERATIONAL. PROTECT EQUIPMENT AND CABLING DURING CONSTRUCTION. PROVIDE AND INSTALL DOOR BELL EATON PART NUMBER - PUSH BUTTON HT8AAHAB WITH STAINLESS STEEL PLATE OR APPROVED EQUIVALENT. PROVIDE AND INSTALL PLENUM RATED BELDON AWG CONDUCTOR CABLE OR EQUIVALENT. PROVIDE AND INSTALL DOOR CHIME HONEYWELL PART NUMBER - RCW0N008-WIRED OR APPROVED EQUIVALENT. PROVIDE AND INSTALL LYNX DURESS BUTTON - PART NUMBER - LYNX-N-PP-M. PROVIDE AND INSTALL DOOR RELEASE BUTTON SDC SECURITY PART NUMBER - -. PROVIDE AND INSTALL PLENUM RATED BELDON AWG CONDUCTOR CABLE OR EQUIVALENT. DATA CABLE WITH 0-FEET OF SLACK NEATLY COILED AND STORED ON J-HOOK ABOVE ACCESSIBLE CEILING FOR OWNER PROVIDED / OWNER INSTALLED ACCESS CONTROL DOORS. CONTRACTOR SHALL PLACE A YELLOW ADHESIVE DOT ON THE CEILING GRID DIRECTLY BELOW THE OUTLET LOCATION FOR FUTURE IDENTIFICATION OF THE OUTLET LOCATION.

35 IT ROOM T RACK ELEVATION DEMO KEYED NOTES EXISTING 9-INCH X 8-INCH EQUIPMENT RACK (BY DIV. 7) IT ROOM T LAYOUT DEMO KEYED NOTES -IN ABOVE FINISHED FLOOR. PAINT WITH () COATS OF FIRE RETARDANT PAINT. PAINT COLOR SHALL BE APPROVED BY THE ARCHITECT/ENGINEER PRIOR TO PAINTING. (BY DIV. 7) EXISTING 9-INCH X 8-INCH EQUIPMENT RACK WITH VERTICAL WIRE MANAGERS. (BY DIV. 7) EXISTING -INCH LADDER RACK MOUNTED AT 8-INCH ABOVE FINISHED FLOOR. (BY DIV. 7) EXISTING GROUND BUS BAR MOUNTED AT 8-INCHES ABOVE FINISHED FLOOR. (BY DIV. 7) EXISTING DAS SYSTEM 6 EXISTING DOUBLE-SIDED VERTICAL WIRE MANAGER (BY DIV. 7) EXISTING RU RACK MOUNTED FIBER OPTIC ENCLOSURE FOR INTRA-BUILDING AND HORIZONTAL MULTIMODE FIBER OPTIC CABLE. PROTECT THE BACKBONE FIBER DURING ALL CONSTRUCTION ACTIVITIES (BY DIV 7) EXISTING 00-PAIR 9-INCH FIELD TERMINATION PANEL FOR INTER-BUILDING COPPER BACKBONE CABLE (BY DIV. 7) EXISTING HORIZONTAL CABLE MANAGER (BY DIV. 7) EXISTING NETWORK SWITCHES. PROTECT THESE SWITCHES DURING ALL CONSTRUCTION ACTIVITIES. (BY DIV. 7) SAN ANTONIO technology & security AUSTIN 6 6 IT ROOM T RACK ELEVATION KEYED NOTES EXISTING 9-INCH X 8-INCH EQUIPMENT RACK (BY DIV. 7) EXISTING DOUBLE-SIDED VERTICAL WIRE MANAGER (BY DIV. 7) IT ROOM T LAYOUT RENOVATED KEYED NOTES -IN ABOVE FINISHED FLOOR. PAINT WITH () COATS OF FIRE RETARDANT PAINT. PAINT COLOR SHALL BE APPROVED BY THE ARCHITECT/ENGINEER PRIOR TO PAINTING. (BY DIV. 7) EXISTING 9-INCH X 8-INCH EQUIPMENT RACK WITH VERTICAL WIRE MANAGERS. (BY DIV. 7) EXISTING -INCH LADDER RACK MOUNTED AT 8-INCH ABOVE FINISHED FLOOR. (BY DIV. 7) EXISTING GROUND BUS BAR MOUNTED AT 8-INCHES ABOVE FINISHED FLOOR. (BY DIV. 7) EXISTING DAS SYSTEM EXISTING RU RACK MOUNTED FIBER OPTIC ENCLOSURE FOR INTRA-BUILDING AND HORIZONTAL MULTIMODE FIBER OPTIC CABLE. PROTECT THE BACKBONE FIBER DURING ALL CONSTRUCTION ACTIVITIES (BY DIV 7) EXISTING 00-PAIR 9-INCH FIELD TERMINATION PANEL FOR INTER-BUILDING COPPER BACKBONE CABLE (BY DIV. 7) NEW 8-PORT RACK MOUNTED PATCH PANEL FOR DATA CABLES (BY DIV. 7) NEW DOUBLE SIDED HORIZONTAL CABLE MANAGER (BY DIV. 7) EXISTING HORIZONTAL CABLE MANAGER (BY DIV. 7) EXISTING NETWORK SWITCHES. PROTECT THESE SWITCHES DURING ALL CONSTRUCTION ACTIVITIES. (BY DIV. 7)

36 SAN ANTONIO technology & security AUSTIN CEILING/DECK CABLE BUNDLE DOUBLE SIDED VERTICAL WIRE MANAGEMENT WALL MOUNTED BUS BAR J-BOLT KIT BUTT-SWIVEL SPLICE KIT CABLE RUNWAY EXISTING EQUIPMENT RACK WITH DOUBLE SIDED VERTICAL WIRE MANAGEMENT JUNCTION SWIVEL SPLICE KIT RACK TO RUNWAY MOUNTING PLATE RACK TO RUNWAY MOUNTING PLATE TYPICAL ELEVATION TYPICAL J-HOOK CABLE PATHWAY DETAIL TYPICAL CONDUIT SLEEVE GOING THRU FLOOR OR DECK TYPICAL CONDUIT SLEEVE GOING THRU WALL TYPICAL TECHNOLOGY CONDUIT ROUGH-IN TYPICAL DUAL DATA WORKSTATION CONFIGURATION TYPICAL SINGLE DATA WORKSTATION CONFIGURATION TYPICAL SINGLE DATA WORKSTATION CONFIGURATION WITH () " CONDUITS TYPCIAL EMPTY ROUGH-IN CONFIGURATION TYPICAL TRIPLE DATA WORKSTATION CONFIGURATION SINGLE DOOR TYPICAL ABOVE CEILING SINGLE DATA OUTLET TYPICAL ABOVE CEILING DUAL DATA OUTLET TYPICAL CARD READER ROUGH-IN - ELECTRIFIED EXIT DEVICE PANIC BUTTON - KNEE SPACE MOUNT

37 FINAL DESIGN

38 FINAL DESIGN

39 FINAL DESIGN

40 FINAL DESIGN

41 FINAL DESIGN

42 UTHSCSA Academic Administrative Building of PART - GENERAL SECTION STRUCTURED CABLING SYSTEM. This section identifies the requirements, technical design, and specifications for the structured cabling system for the University of Texas Health Science Center at San Antonio for PARC Office Building, located in San Antonio, Texas ( Owner ). The structured cabling system as specified is an Industry-Standard Category e structured cabling system and includes backbone cabling, horizontal cabling and equipment room hardware as specified.. The Contractor shall provide a Manufacturer s 0-Year Performance Certification for the installed structured cabling system.. Contractor shall include materials, equipment, and labor necessary to provide a complete and functional structured cabling system regardless of any items not listed or described in this specification or associated drawings.. Requirements A. Contractor Experience Requirements B. Submittal Requirements C. Acceptable Manufacturers D. Codes, Standards and Regulations E. General Requirements F. System Requirements G. Testing Requirements H. Project Closeout Documentation I. Attachments. Related Requirements A. The Drawings, Specifications, General Conditions, Supplementary General Conditions, and other requirements of Division apply to the work specified in Division 7, and shall be complied with in every respect. The Contractor shall examine all of the items which make up the Contract Documents, and shall coordinate them with the work on the project. B. Contractor Experience Requirements. The Contractor shall be a Siemon Certified Installer prior to submitting a bid for the work.. The Contractor shall possess all relevant Manufacturer Certifications (i.e. structured cable systems, testing equipment, etc,) for both the company and individual technicians prior to submitting a bid for the work. 00% CONSTRUCTION DOCUMENTS STRUCTURED CABLING

43 UTHSCSA Academic Administrative Building of. The Contractor s Project Manager shall be a Registered Communications Distribution Designer (RCDD) and available for all onsite coordination meetings.. The Contractor shall have been in business for a minimum of five () years.. The Contractor shall have a local office with local technicians and an adequate workforce to complete this project within a 7-mile radius of the project site. 6. The Contractor shall have completed a minimum of five () projects similar in size and scope to the Owner s installation, where the systems have been in continuous satisfactory operation for at least one () year. C. Subcontractors shall be identified at the time of bid and comply with the requirements and intentions of these specifications, associated drawings, and related contract documents..6 Submittal Requirements A. Pre-Installation Submittal. Contractor shall not order, purchase, or install any equipment until preinstallation submittals have been accepted in writing by the Architect/Engineer.. All submittals shall be submitted in the same sequence as they are listed in the specifications (i.e. product data in the sequence items are listed in the product data section, manufacturer product certifications for company, manufacturer product certifications for installers, etc.). Submittals not in the proper sequence will not be approved.. Manufacturer product data sheets for each proposed system component. a. For product data sheets containing more than one () part number or product, the Contractor shall clearly identify the specific part number or product being submitted. Product data sheets without the part number clearly identified will not be approved.. Manufacturer Product Certifications for Company.. Manufacturer Product Certifications for Installers. 6. Manufacturer Certifications for testing equipment technicians. 7. Manufacturer Certifications for testing equipment calibration. 8. RCDD Certificate for Contractor s Project Manager. 9. Manufacturer Warranty letter. 0. Documentation indicating that Contractor has been in business for () years. 00% CONSTRUCTION DOCUMENTS STRUCTURED CABLING

44 UTHSCSA Academic Administrative Building of. Address of Contractor s local office within a 7-mile radius of the project site.. Quantity of full time local technicians within a 7-mile radius of the project site.. List of five () contractor-installed projects of a similar size and scope that have been in operation for at least () year. The Contractor shall provide the following information for each project: Project Name, Project Location, Project Start Date, Project Completion Date, Project Start Cost, Project Completion Cost, Brief Description of Project, Client Point of Contact Name and Phone Number.. List of completed and ongoing projects with the Owner. The Contractor shall provide the following information for each project: Project Name, Project Location, Project Start Date, Project Completion Date, Project Start Cost, Project Completion Cost, and Brief Description of Project.. List of subcontractors performing any work on the project. List shall clearly identify the subcontractor s legal name and address, the scope of work to be performed by the subcontractors and the overall percentage of the project being provided by the subcontractor. If there are no subcontractors performing any work on the project, submit a statement on company letterhead clearly indicating no subcontractors will be performing any work on this project. 00% CONSTRUCTION DOCUMENTS STRUCTURED CABLING

45 UTHSCSA Academic Administrative Building of PRODUCTS. General Requirements A. The following sections specifically list the acceptable equipment types and items for this project. B. Architect/Engineer will have final determination of acceptability of all proposed equipment and must approve submitted equipment prior to purchase or installation. C. Proposed equivalent items must be approved in writing by the Architect/Engineer prior to purchase or installation. Proposed equivalent items must meet or exceed these specifications and the specifications of the specified item. D. In the event a manufacturer s specified product or part number has changed or is no longer available, Contractor shall substitute the appropriate equivalent manufacturer s part number. E. In the event of a discrepancy between the specifications and the drawings, the greater quantity and/or better quality will be furnished. F. For listed products with no part number specified, Contractor shall provide a product that meets the performance requirements of these specifications, industry standard practices, and intended application. G. All wiring, equipment, and installation materials shall be new and of the highest quality. H. Labels on all cabling, materials, and equipment must indicate a nationally recognized testing laboratory. I. Original Equipment Manufacturer (OEM) documentation must be provided to the Architect/Engineer which certifies performance characteristics and compliance with ANSI/TIA/EIA 68-C standards.. Acceptable Manufacturers A. Horizontal Cable. Category e UTP Plenum a. Network Access (Blue Sheath) ) Belden DataTwist 00 Part Number 70A DU000. Category e UTP Flooded a. OSP (Gray Sheath) ) Belden DataTwist OSP UTP Part Number 9A 008U000 B. Copper Cable Termination. Category e Horizontal Rack Mounted Patch Panels a. Siemon HD 8-Port Patch Panel Part Number HD-8 00% CONSTRUCTION DOCUMENTS STRUCTURED CABLING

46 UTHSCSA Academic Administrative Building of. Category e Modular Jacks a. Network Access (Ivory) ) Field End a) Siemon Category e Angled Double Coupler (Ivory) Part Number CT-C-C-0 b) Siemon Category e Flat MAX (For Surface Mounted Box) (Ivory) Part Number MX-F-0 c) Red Icon b. Voice Access ) Field End (Ivory) a) Siemon Category e Angled Double Coupler (Ivory) Part Number CT-C-C-0 b) Siemon Category e Flat MAX (For Surface Mounted Box) (Ivory) Part Number MX-F-0 c) Blue Icon. Telecommunications Faceplates with Designation Window Coordinate color with Architect prior to ordering. a. -Coupler Single Gang Flush (Ivory) ) Siemon Wallplate with ID Window Part Number CT-FP-0 b. -Coupler Double Gang Flush (Ivory) ) Siemon Wallplate with ID Window Part Number CT8-FP-0 c. Wall Phone Faceplate (Stainless Steel) ) Siemon MAX Series Stainless Steel Wall Phone Faceplate with Keystone MAX Module Included Part Number MX-WP-(XX)SS d. -Port Universal Modular Furniture Adapter ) The Siemon Company Part Number CT-UMA-0 e. -Port Modular Furniture Adapter for Steelcase ) The Siemon Company Part Number CT-MFP-0 f. -Port Modular Furniture Adapter for Herman Miller ) The Siemon Company Part Number CT-MFP-HMA-0. -Port MX-SM Surface Mount Box (White) a. The Siemon Company - Part Number MX-SM-0. -Port MX-SM Surface Mount Box (White) 00% CONSTRUCTION DOCUMENTS STRUCTURED CABLING

47 UTHSCSA Academic Administrative Building of a. The Siemon Company Part Number MX-SM-0. Blank Insert (White) a. a. The Siemon Company Part Number MX-SM-BLNK-0 F. Equipment Racks, Cabinets, Cable Management, and Accessories. Horizontal Cable Managers (Black) a. Chatsworth Rack Cabling Manager - Part Number Vertical Power Strip for 7 Equipment Rack a. Chatsworth 0 Outlet (-0R) Power Strip with Meter and NEMA -0P Part Number 8-7 G. Access Control Cabling. Card Reader Composite Cable a. Superior Essex b. Beldon c. Or approved equal. H. Pathway Cable Support. Panduit J-Mod Cable Support System. Erico CADDY CAT LINKS J-Hook Series. Erico Caddy Adjustable Cable Support Series. Panduit Plenum Rated Hook & Loop (Black). Erico Caddy Grid Support Part Number ATA or ATS I. Grounding and Bonding. Grounding Bus Bar, 0 a. Chatsworth - Part Number Grounding Bus Bar, a. Chatsworth - Part Number 6-0. Cable Runway Ground Strap Kit a. Chatsworth - Part Number Hole Compression Lugs a. Chatsworth - Part Number 06-9XX* *XX Denotes wire size and hole spacing 00% CONSTRUCTION DOCUMENTS STRUCTURED CABLING

48 UTHSCSA Academic Administrative Building of. #6 AWG Solid Green Insulation Ground Wire a. Superior Essex - Part Number #/0 Stranded Green Insulation Ground Wire 7. Cable Sheath Bonding Clamp J. Labeling. Permanent Labels for Fiber Optic Cables a. Brady b. Panduit Self Laminating Labels. Permanent Labels for Innerduct a. Panduit Dome-Top Ty Marker. Permanent Labels for Copper Cables a. Panduit Self-Laminating Labels. Permanent Labels for Backbone Fiber Optic Cables a. Panduit Dome-Top Ty Marker. Permanent Labels for Patch Panels a. Panduit Component Label 6. Permanent Labels for Faceplates a. Panduit Component Label K. Fire Stop. STI Spec Seal Part Number. M Products Part Number L. Plywood. 8 H x W x ¾ Sheets of BC grade fire-rated plywood M. Fire Retardant Paint (White) N. Fiber Patch Cables. The Siemon Company a. The Siemon Company Single Mode LC LC Patch Cables Part Number FJ-LCULCUL(XX)*HN O. Copper Patch Cables. MDF / IDF Rooms 00% CONSTRUCTION DOCUMENTS STRUCTURED CABLING

49 UTHSCSA Academic Administrative Building of a. The Siemon Company MC e UTP Modular Cords - Part Number MC-8-T- (XX)-YY*. Workstations a. The Siemon Company MC e UTP Modular Cords - Part Number MC-8-T- ()-YY* XX Denotes Length Confirm prior to ordering YY Denotes Color Confirm prior to ordering 00% CONSTRUCTION DOCUMENTS STRUCTURED CABLING

50 UTHSCSA Academic Administrative Building of EXECUTION. Codes, Standards, Regulations A. American National Standards Institute (ANSI) B. American Society for Testing and Materials (ASTM). ASTM B (00; R 007) Standard Specification for Hard-Drawn Copper Wire. ASTM B 8 (00) Standard Specification for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft. ASTM D 7 (007) Standard Test Methods for Laboratory Compaction Characteristics of Soil Using Modified Effort (6,000 ftlbf/ft) (700 kn-m/m). ASTM D 709 (00; R 007) Laminated Thermosetting Materials C. Alliance for Telecommunications Industry Solutions (ATIS) D. Building Industry Consulting Service International (BICSI). Telecommunications Distribution Methods Manual th Edition. Outside Plant Design Reference Manual th Edition. ANSI/BICSI 00-0, Data Center Design and Implementation Best Practices. NECA/BICSI Standard for Installing Commercial Building Telecommunications Cabling. NECA/BICSI 607-0, Standard for Telecommunications Bonding and Grounding Planning and Installation Methods for Commercial Buildings E. Electronics Industry Alliance (EIA) F. Federal Communications Commission (FCC). FCC Part, Radiated Emissions Limits, revised 998. FCC Part 68, Connection of Terminal Equipment to the Telephone Network, revised 998. FCC Part 76, Cable Television Service, revised 998 G. Insulated Cable Engineers Association (ICEA). ICEA S (006) Fiber Optic Outside Plant Communications Cable. ICEA S (006) Broadband Twisted Pair, Telecommunications Cable Aircore, Polyolefin Insulated Copper Conductors. ICEA S (006) Broadband Twisted Pair Telecommunications Cable Filled, Polyolefin Insulated Copper Conductors 00% CONSTRUCTION DOCUMENTS STRUCTURED CABLING

51 UTHSCSA Academic Administrative Building of H. International Electrotechnical Commission (IEC) I. Institute of Electrical and Electronics Engineers, Inc. (IEEE). IEEE Standard 8-98, IEEE Guide for Measuring Earth Resistance, Ground Impedance, and Earth Surface Potential of a Ground System. IEEE Standard , Recommended for practice for Powering and Grounding Sensitive. Electronic Equipment in Industrial and Commercial Power Systems (IEEE Emerald Book). IEEE C (007; Errata 007; INT 008) National Electrical Safety Code. IEEE Std 00 (000) The Authoritative Dictionary of IEEE Standards Terms J. International Organization for Standardization (ISO). International Organization of Standardization/International Electrotechnical Commission (ISO/IEC). ISO/IEC 80, Information Technology-Generic Cabling for Customer Premises, 99. ISO/IEC 76-, Information Technology-Implementation and Operation of Customer Premises Cabling-Administration, 999. ISO/IEC 80, Information Technology-Generic Cabling for Customer Premises, 99. ISO/IEC 76-, Information Technology-Implementation and Operation of Customer Premises Cabling-Administration, 999 K. National Cable Television Association (NCTA) L. National Electrical Manufacturers Association (NEMA). NEMA C6.6 (99) Gas Tube Surge Arresters on Wire Line Telephone Circuits M. National Fire Protection Association (NFPA). NFPA-70, National Electrical Code. NFPA-7, Protection of Electronic Computer Data Processing Equipment.. NFPA-0, Life Safety Code. NFPA-97, Guide on Principles and Practices for Telecommunications Systems. NFPA-780, Standard for the Installation of Lightning Protection Systems. N. National Institute Standards and Technology (NIST) 00% CONSTRUCTION DOCUMENTS STRUCTURED CABLING

52 UTHSCSA Academic Administrative Building of O. Occupational Safety and Health Administration (OSHA) P. Telecommunications Industry Association (TIA). ANSI/TIA-68-C.0, Generic Telecommunications Cabling for Customer Premises, 009. ANSI/TIA-68-C., Commercial Building Telecommunications Cabling Standard, 009. ANSI/TIA -68-C., Balanced Twisted-Pair Telecommunications Cabling and Components Standard, 009. ANSI/TIA-68-C., Optical Fiber Cabling Components Standard, 008. ANSI/TIA/EIA 69-B, Commercial Building Standard for Telecommunications Pathways and Spaces, ANSI/TIA 69-B Amendment, Commercial Building Standard for Telecommunications Pathways and Spaces, ANSI/TIA/EIA-606-B, Administration Standard for the Telecommunications Infrastructure of Commercial Buildings, 0 8. ANSI/TIA/EIA-607-B, Commercial Building Grounding and Bonding Requirements for Telecommunications, 0 9. ANSI/TIA-78, Customer-Owned Outside Plant Telecommunications Infrastructure Standard, 00 Q. U.S. Department of Agriculture (USDA). RUS 7 Telecommunications Standards and Specifications for Materials, Equipment and Construction. RUS Bull 7F-6 (00) Underground Plant Design. RUS Bull 7F-8 (979) Electrical Protection of Outside Plant. RUS Bull 7F-0 (997) Acceptance Tests of Telecommunications Plant (PC-). RUS Bull 7F-0 (99) Splicing Copper and Fiber Optic Cables (PC-) 6. RUS Bull -6 (98) Shield Bonding Connectors (PE-6) 7. RUS Bull -7 (98) Filled Splice Closures (PE-7) 8. RUS Bull -8 (979; Rev Oct 98) Gas Tube Surge Arrestors (PE-80) R. Underwriters Laboratories, Inc. (UL). UL 0 (00; Rev thru Aug 00) Polyvinyl Chloride, Polyethylene, and Rubber Insulating Tape. UL 90 (NFPA 6 990) Applicable Flame Test 00% CONSTRUCTION DOCUMENTS STRUCTURED CABLING

53 UTHSCSA Academic Administrative Building of.0 In the event of any conflicts between documents referenced herein and the contents of this specification, the Contractor shall notify the Architect/Engineer in writing of any such occurrences before purchasing or installing any equipment or materials. The Architect/Engineer will notify the Contractor of any actions required to resolve these conflicts. Such actions may include but are not limited to: design changes, equipment, materials and/or installation changes. In any event Contractor shall not supersede specifications and standards from the latest NFPA and NEC publications. In the event of any conflicts between Standards and Codes the more stringent shall take precedence..0 General Requirements A. Contractor shall comply with the requirements of local Authority Having Jurisdiction (AHJ), State of Texas, the National Fire Protection Association (NFPA), and the National Electrical Code (NEC). If the Contractor identifies any item in the plans or specifications that will not strictly comply with the aforementioned laws, ordinances, and rules, the matter shall be referred to the Architect/Engineer for direction before proceeding with that part of the work. B. The Contractor shall be responsible for coordination with other trades to ensure any conflicts or potential conflicts are resolved prior to any work beginning on the project. C. The Contractor shall install the materials in accordance with these specifications and the manufacturer s installation guidelines. D. No deviations from the plans or specifications shall be made without full consent in writing of the Architect/Engineer. The Contractor shall have written approval from the Architect/Engineer for any additional work beyond the Contract Documents prior to beginning such work. If the Contractor does not obtain written approval from the Architect/Engineer prior to proceeding with the work, the contractor shall not be reimbursed for the work. E. The Contractor shall obtain written permission from the Architect/Engineer before proceeding with any work that would necessitate cutting into or through any part of the building structure such as, but not limited to girders, beams, floors, walls, roofs, or ceilings. F. Contractor shall notify the Architect/Engineer a minimum of () weeks prior to beginning work and will participate in a pre-construction meeting with the Architect/Engineer to perform a walkthrough, review the scope of work, schedule, and escalation procedures. G. The Contractor shall maintain a work area free of debris, trash, empty cable reels, scrap cable, etc., and dispose of such items on a daily basis and return the site to the original state of cleanliness. The Contractor shall not use Owner s facilities for the disposal of excess or scrap materials. H. Equipment and materials installed by the Contractor shall be free of defects and damage. I. Contractor shall be responsible for the repair of any damage caused by the contractor during the installation. J. Contractor shall test all cables prior to installation. By failing to perform this testing operation, the Contractor shall accept the cable as compliant and 00% CONSTRUCTION DOCUMENTS STRUCTURED CABLING