ELECTRICAL & TELECOMMUNICATIONS DUCTING & CONDUIT PVC & POLYETHYLENE SYSTEMS

Size: px
Start display at page:

Download "ELECTRICAL & TELECOMMUNICATIONS DUCTING & CONDUIT PVC & POLYETHYLENE SYSTEMS"

Transcription

1 ELECTRICAL & TELECOMMUNICATIONS DUCTING & CONDUIT PVC & POLYETHYLENE SYSTEMS 1

2 PVC RIGID ELECTRICAL CABLE DUCT Iplex PVC electrical cable ducts are rigid conduits as defi ned in AS / NZS They are intended for durable underground installation using conventional open cut trench methods, to identify and protect contained underground electrical cables. If used unprotected from the sun above ground, UV / weathering resistance of the duct will be limited and colour fading (whitening), with some loss of impact strength will occur over time. DN 80, 100 and 150mm NB ducts colored orange are manufactured in accordance with AS/NZS :2001 Conduits and fi ttings for electrical installations - Part 2: Rigid plain conduits and fi ttings of insulating material DN 32, 40 and 50 NB ducts colored orange are manufactured to the OD and wall thickness dimensions of AS / NZS 1260: SOE HD.6SOE Technical data and product range available: Nominal Iplex Order Code *Classification Colour #Joint Type Outside Thickness 32mm SOE N.A. Orange Spigot/Socket SCJ mm SOE N.A. Orange Spigot/Socket SCJ mm SOE N.A. Orange Spigot/Socket SCJ mm LD.6 SOE Light duty Orange Spigot/Socket SCJ mm LD.6 SOE Light Duty Orange Spigot/Socket SCJ mm LD.6 SOE Light Duty Orange Spigot/Socket SCJ mm HD.6 SOE Heavy Duty Orange Spigot/Socket SCJ (SN40) 150mm HD.6 SOE Heavy Duty (SN40) Orange Spigot/Socket SCJ *Classifi cation: as depicted in Table 101, AS/NZS :2001 # SCJ = Solvent Cement Joint 2

3 PVC RIGID ELECTRICAL CONDUIT Iplex PVC Electrical Conduits are pliable conduits as defi ned in AS/NZS :2001 They are colored either orange or grey and intended for durable above-ground installation inside commercial and domestic buildings, to identify and protect contained electrical wiring or cables. If used unprotected from the sun above ground, UV / weathering resistance of the conduit will be limited and colour fading (whitening), with some loss of impact strength will occur over time. 20mm, 25mm, 32mm, 40mm and 50mm NB PVC conduits colored orange or grey are manufactured in accordance with AS/NZS :2001 Conduits and fi ttings for electrical installations - Part 2: Rigid plain conduits and fi ttings of insulating material Medium Duty SOE (Grey) SOE (Orange) Technical data and product range available: Nominal Iplex Order Code *Classification Colour #Joint Type Outside Thickness 20mm SOE Medium Duty Grey Spigot/Socket SCJ mm SOE Medium Duty Grey Spigot/Socket SCJ mm SOE Medium Duty Grey Spigot/Socket SCJ mm SOE Medium Duty Grey Spigot/Socket SCJ mm SOE Medium Duty Grey Spigot/Socket SCJ mm SOE Medium Duty Orange Spigot/Socket SCJ mm SOE Medium Duty Orange Spigot/Socket SCJ mm SOE Medium Duty Orange Spigot/Socket SCJ mm SOE Medium Duty Orange Spigot/Socket SCJ mm SOE Medium Duty Orange Spigot/Socket SCJ *Classifi cation: as depicted in Table 101, AS/NZS :2001 # SCJ = Solvent Cement Joint 3

4 PVC TELECOMMUNICATION DUCTING (Chorus Branded) (Sold only to Chorus approved installers*) Iplex Pipeline s range of PVC telecommunication ducting is available for telecommunication projects requiring cable protection * Only approved Chorus Contractors can purchase and install these products. For further details please contact Iplex Pipelines. PVC TELECOMMUNICATION REPAIR SLEEVE (Chorus Branded) 20mm Telecommunications Duct (Chorus branded) Size Iplex Order Code Colour Joint Type Outside Size Iplex Order Code Colour Joint Type Internal Thickness 20mm x 6m Green Spigot/Socket,SCJ mm x 6m White Spigot/Socket, SCJ mm x 6m P4001 Green Rubber Ring Joint mm x 6m P4000 Green Rubber Ring Joint Thickness 50mm x 2m Green Plain end,scj mm x 2m Green Plain end, SCJ Repair sleeve slides over the outside of the PVC telecommunication duct, and is joined to the duct with PVC solvent cement. 100mm PVC Repair sleeve 100 mm green PVC Telecommunication ducts, showing horizontal separation in the trench space from other services such as telecommunications (green and purple), potable water (white) and gas (yellow) Also trench wall is marked to locate backfi ll compaction zones above the pipes 50mm PVC Repair sleeve 4

5 COILED PE TELECOMMUNICATION DUCT (Chorus Branded) ORDER CODE COLOUR SIZE mm COIL LENGTH m GREEN 20mm 200m BLACK with RED TRI-STRIPE 32mm 1000m BLACK with RED TRI-STRIPE 32mm 500m BLACK with GREEN TRI-STRIPE 32mm 1000m BLACK with GREEN TRI-STRIPE 32mm 500m BLACK with VIOLET TRI-STRIPE 32mm 1000m BLACK with VIOLET TRI-STRIPE 32mm 500m BLACK with BROWN TRI-STRIPE 32mm 1000m BLACK with BROWN TRI-STRIPE 32mm 500m 100m Coils PE telecommunication duct SDR17 DN 32 PE sub- ducts inside 100mm PVC carrier ducts, at a roadside connection pit PVC-U TELECOMMUNICATION BENDS (Chorus Branded) ORDER CODE COLOUR SIZE mm GREEN 20mm x 90 ROD* GREEN 20mm x 90 ROD* GREEN 20mm x 90 ROD* WHITE 20mm x 90 ROD* WHITE 20mm x 90 ROD* GREEN 50mm x 30 ROD* GREEN 50mm x 45 ROD* GREEN 50mm x 45 ROD* GREEN 50mm x 45 ROD* GREEN 50mm x 90 ROD* GREEN 50mm x 90 ROD* GREEN 100mm x 22 ROD* GREEN 100mm x 30 ROD* GREEN 100mm x 45 ROD* ** GREEN 100mm x 90 ROD* GREEN 100mm x 90 ROD* GREEN 100mm x 90 ROD* GREEN 100mm x 90 ROD*900 *Radius of **F&F Bend 20MM FORMED BEND 50MM FORMED BEND M&F 100MM FORMED BEND M&F PVC-U TELECOMMUNICATION FITTINGS (Chorus Branded) ORDER CODE COLOUR SIZE mm GREEN 50mm ORDER CODE COLOUR SIZE mm GREEN 50mm x 20mm COUPLER ORDER CODE COLOUR SIZE mm P4004 BLACK 50mm P4005 BLACK 100mm REDUCING SADDLE DUST CAP 5

6 COILED POLYETHYLENE ELECTRICAL DUCT Iplex Pipeline s range of polyethylene cable ducting complements the use of trenchless installation methods, including Horizontal Directional Drilling, under roads and built up areas, or where conventional open cut trenching is impractical. The available PE duct range conforms dimensionally to AS/NZS 4130, PE Pipes for Pressure Applications, for SDR17 duct using PE80 (MDPE) materials. Two DN 110 PE electrical ducts in 50m coils on a dual-coil dispensing trailer Technical data and product range available: DN 110 PE electrical ducts with pull heads in place, ready for pull-in by horizontal directional drilling OD mm Iplex Code Colour Coil Length SDR Rating Outside Thickness 32 CABLE DUCT OR 32/ All Orange 200m CABLE DUCT OR 32/ All Orange 500m CABLE DUCT OR 63/ All Orange 100m CABLE DUCT OR 63/ All Orange 150m CABLE DUCT OR 90/79.50 All Orange 50m CABLE DUCT OR 90/ All Orange 100m CABLE DUCT OR 110/97.50 All Orange 50m CABLE DUCT OR 110/ All Orange 100m CABLE DUCT OR 125/ All Orange 100m COILED POLYETHYLENE TELECOMMUNICATION DUCT Iplex Pipeline s ability to color or color-stripe polyethylene ducting, assists the duct asset owner with identifi cation in multiple duct applications. 6 DN 32 PE telecommunication duct in a 500m coil on a coil dispensing trailer DN 110mm PE telecommunication duct in a 100m coil on a coil dispensing trailer

7 29 COILED PE TELECOMMUNICATION DUCT SDR 17 (GREEN) Technical data and product range available: O.D Iplex Code Colour Coil Length SDR Rating Outside Thickness 32 TELEDUCT PE32/ Lime Green 200m TELEDUCT PE32/ Lime Green 500m TELEDUCT PE63/ Lime Green 100m TELEDUCT PE63/ Lime Green 150m TELEDUCT PE110/97.50 Lime Green 50m TELEDUCT PE110/ Lime Green 100m PVC-U TELECOMMUNICATION DUCT ORDER CODE COLOUR SIZE MM LD.6 SOE GREEN 100 x SOE RED 50 x LD.6 SOE RED 100 x 6 SOCKET ONE END ELECTRICAL AND TELECOMMUNICATION FITTINGS Iplex Pipelines has a range of PVC and polyethylene fi ttings for use with electrical and telecommunication ducting. The most common fi ttings are the post-formed bends. Other fi ttings, such as tees, y-junctions, couplers etc are available. For more information on these fi ttings contact Iplex Pipelines. PVC-U ELECTRICAL CABLE DUCT BENDS (ORANGE) ORDER CODE COLOUR SIZE MM ORANGE 50 x 45 o ORANGE 50 x 90 o ORANGE 80 x 45 o ORANGE 80 x 90 o R250 ORANGE 100 x 45 o ROD* 250mm R250 ORANGE 100 x 90 o ROD* 250mm R900 ORANGE 100 x 90 ROD* 900mm *Radius of FORMED ELECTRICAL BEND F&F PVC-U CABLE DUCT BENDS (WHITE) ORDER CODE COLOUR SIZE MM CD WHITE 20 x 45 CD WHITE 20 x 90 PIPE INSTALLATION GUIDELINES How I Install PVC Pipes by Percival Vincent Cuttingsworth How I Solvent Cement Joint PVC Pipes by Percival Vincent Cuttingsworth Refer to How I install PVC Pipes Available at Refer to How I solvent Cement Joint PVC Pipes available at Refer to How I Install PE Pipes available at 7

8 Product Range from Iplex Pipelines NOVADRAIN & NOVACOR PVC DRAIN WASTE & VENT SYSTEMS RESTRAIN DRILLABLE PVC GRAVITY SEWER PIPE POLIDRAIN POLYETHYLENE DRAINAGE SYSTEM SUPERSTORM & STORMFIT PVC STORMWATER DUCT SYSTEM NEXUS HI-WAY ROAD DRAINAGE SYSTEM NOVAKEY & BLUE BRUTE PVC-U PRESSURE SYSTEMS WHITE & BLUE RHINO HIGH IMPACT PVC-M PRESSURE PIPE APOLLO & APOLLOBLUE PVC-O PRESSURE PIPE NOVAFUSE FUSIBLE PVC PIPE BLUELINE & POLIPLEX MEDIUM DENSITY POLYETHYLENE PIPE ALKATHENE LOW DENSITY POLYETHYLENE PIPE NOVATUBE HORTICULTURAL LATERAL TUBE GREENLINE, REDLINE, RURAL BLACK, BLACKLINE & BLACKLINE HP POLYETHYLENE PRESSURE PIPE PLASSON METRIC COMPRESSION FITTINGS NEXUS FLO, NEXUS COIL, NOVAFLO & NOVACOIL LAND DRAINAGE SYSTEMS IPLEX EFFLUENT PIPE MEDIUM DENSITY POLYETHYLENE PIPE FARMTUFF & NEXUS CULVERT CULVERT PIPE POLIGAS POLYETHYLENE GAS SYSTEMS 2016 IPLEX PIPELINES (NZ) LIMITED. NEXUS, IPLEX, RESTRAIN, APOLLO, NOVAFLO, FARMTUFF, NOVAKEY, NOVAFUSE, POLIGAS, RHINO, REDLINE, POLYDRAIN, SUPERSTORM are registered trademarks of IPLEX PIPELINES (NZ) LIMITED. Version 2 This version supersedes all previous versions or editions of this brochure. 8 Important Disclaimer The information, opinions, advice and recommendations contained in this publication are put forward with the main objective of providing a better understanding of technical matters associated with pipeline design using Iplex Pipelines. Whilst all reasonable care has been made in ensuring that the information contained in this publication is accurate, this publication should not be used as the only source of information by the reader. Reference should also be made to established textbooks and other published material, and readers should not rely on the information contained in this publication without taking appropriate professional advice for their particular circumstances. Pipes and fi ttings have been shown as typical confi gurations, however, in some cases product dimensions may vary or be changed without notice. In all instances, the reader should contact Iplex Pipelines for clarifi cation that the specifi c product is appropriate for their circumstances. Iplex Pipelines NZ Limited. Call Centre Phone: Fax: Web: redfi sh 16/9/16 ELECTRICAL & TELECOMMUNICATIONS DUCTING & CONDUIT PVC & POLYETHYLENE SYSTEMS Offi ces At: Auckland: Private Bag , 810 Great South Road, Penrose. Palmerston North: Private Bag 11019, 67 Malden Street. Christchurch: PO Box 16225, 22 Braeburn Drive, Sockburn.